Loading...
HomeMy WebLinkAbout9295 W 48th Avenue� ► 44" City of Wheat Ridge '/� Commercial Remodel PERMIT - 202100276 PERMIT NO: 202100276 ISSUED: 06/17/2021 JOB ADDRESS: 9295 W 48th Ave N EXPIRES: 06/17/2022 JOB DESCRIPTION: Caesar Square - Building 5 Complete interior and exterior building renovation - 21,785 sq ft total *** CONTACTS *** OWNER (720)766-1095 JEFFERSON COUNTY HOUSING AUTHO GC ( 3 0 3) 928-1800 SCOTT M. KOHRS 020534 TAYLOR KOHRS , LLC SUB (970)490-1458 BARB RAUS CH 160004 AI R COMFORT, INC. SUB (303) 936-7924 BRAD CHRISTIANSON 080241 RYCH ELECTRIC INC SUB (970)221-1735 BRANDY JONES 202075 LIND'S PLUMBING & HEATING INC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 103 / BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION:1,214,724.00 FEES Total Valuation 0.00 Plan Review Fee 41773.31 Permit Fee 71343.55 ** TOTAL ** 12,116.86 *** COMMENTS *** *** CONDITIONS *** Approval from presiding fire department required prior to final building inspection sign -off. All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IBC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Commercial Remodel PERMIT - 202100276 202100276 9295 W 48th Ave N Caesar Square - Building 5 Complete renovation - 21,785 sq ft total ISSUED: 06/17/2021 EXPIRES: 06/17/2022 interior and exterior building I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/17/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Residential Interior Remodel Date: Friday, February 12, 20219:39:13 AM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 9295 W. 48th Ave Property Owner Name Foothills Regional Housing (Formerly Jefferson County Housing Authority) Property Owner Phone 720-766-1095 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email akloke@foothillsrh.org Address Attach City of Wheat Electronic Payment Form.odf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name Studio 646 Architecture What is your role in the Architect project? Contact Phone Number 720-297-9416 (enter WITH dashes, eg 303-123-4567) Contact Email Address eblase@646arch.com for Plan Review Comments Retype Contractor eblase@646arch.com Email Address DESCRIPTION OF WORK Detailed Scope of Caesar Square Apartments is a renovation project of 108 Work - In the space apartment units within 5 buildings located in Wheat Ridge, below (not as an Colorado. This property is managed and maintained by Jefferson attachment), Provide a County Housing Authority as an affordable housing project in the detailed description of Metro -Denver area. The buildings were originally built in the early work Including 1970's, and have experienced minor renovations over the yars. mechanical, electrical, The scope of this project includes site renovation, reconstruction plumbing work and reconfiguration of the parking area, addition of site amenities, construction of a new construction community center, occurring, and renovation of the residential unit interiors and exteriors of the adding/removing walls, five existing apartment builings.The overall scope also includes etc adding accessibility for those with mobility impaiments. The new commnity building will be constructed as a fully accessible building, and buildings 2 and 3 will be renovated to allow for accessible entry to he buildings, as well as have unit modifie to comply with ANSI Type'A' requirements. This set of documents in only a documentation of the renovation scope for building 3 wih scope items summarized below. BUILDING 3 RENOVATION SUMMARY: 1" = 60'-0" BUILDING 3 - SITE PLAN - PROPOSED 3 1. EXTERIORS a. Repaint existing siding b. Reclad mansard roofs with metal c. Bring stairs / railings up to code d. Add exterior building signage e. Add exterior ramp on north side into building for accessibility. f. Add accessibility modifications at exterior of building. g. Replace exterior sliding windows with casement windows at Type'A' units on level 1. 1. INTERIORS - UNITS a. Asbestos abatement at floors & drywall at bathrooms b. Type'A' Unit modifications c. Replace all new unit entry doors / hardware d. Replace all bath plumbing fixtures / accessories / shower valves e. Replace all kitchen cabinets / plumbing fixtures / appliances / accessories f. Replace all lighting g. Update electrical to code / pig -tailing aluminum wiring h. Repaint all unit interiors: walls / ceilings / shelving / sills / frames i. Replace all unit interior flooring 2. INTERIORS — CORRIDORS a. Replace all light fixtures b. Replace all interior stair railings c. Replace all unit entry doors & add new accessible signage d. Repaint all corridor walls / ceilings / trim e. Replace all corridor flooring f. Remove existing window and door at all exterior building entries and replace with aluminum storefront system I, the applicant, I have entered a detailed scope of work. understand my application will be rejected if I do not include a Detailed Scope of Work. Location of Work Entire building interior - New finishes Square Footage Area of Work Being Performed Asbestos Report Upload letter size documents here Construction Plans scanned on 11'x17" or larger Renovation - No new constuction s.f. 14 53 SEEM STZS rem • -- Field not completed. 2021-0211 Caesar Sauare Buildina 3 Undated Permit Set.odf Project Value (contract 1,214,724 Valuation okay value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for eric blase Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. SUBCONTRACTOR AUTHORIZATION FORM Electrical Subcontractor This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR performing electrical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 9235 - 9355 W. 48th Ave. General Contractor: Taylor Kohrs, LLC Company Name: Rych Electric Contact Phone #: 303.936.7924 Wheat Ridge Contractor License #:6'3ozly( (required field) State License #: �C�7 Master License #: C3(aboc o Printed Name of Authorized Agent Si ure of Authorized Agent /b _ Dat DocuSign Envelope ID 135BF827-FA2D-4A98-9CD2-135439ED2C31 4' City of "�IT Wheat�s,ge COMMUNY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Mechanical Subcontractor TMs form must be completed & signed by the MECHANICAL SUBCONTRACTOR performing mechanical work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: 9235 - 9355 W. 48th Ave. General Contractor: Company Name: Air Comfort Contact Phone #: 970.490.1458 Wheat Ridge Contractor License #:L60004 (required field) Matt Rausch, Cluef Executive Officer Printed Name of Authorized Agent o-USigned by: KaUSlIa. 7/13/20 Srgnaf`ure o uthorized Agent Date f�AIt Ir ctty of Wh6atf �idge COMMUNITY DEVELOPMENT SUBCONTRACTOR AUTHORIZATION FORM Plumbing Subcontractor his fbrm must be ct signrbyrt performing plumbing work on site. Subcontractor's insurance and license must be up to date prior to permit issuance. Project Address: General Contractor: L -,c FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION Company Name: L nd 5 �i)4 I iIC- Contact Phone #: R -7b—aa 1 �� Wheat Ridge Contractor License #: T 0 (required field) State License #: M( Com/ r-� Master License #: D �� LD. J� J 14LI, 1 6 fflm( Printed Name of Authorized Agent z 1'ell Signature of Authorized Agent & � J 00@0 Date i� �l/heat �l�e APPROVED Eavlawad W C:Otla CalInnhatte kirkmoney 05/07/2021 Plans Lunrwr tats �� 7ne trNeM ei r mov.* ew. u Okoi mYeBgbt6MY.9JMtwlt Of.iN�'wrJlS.a+'en�atsnl C( trM luf.le"k a� gPter Pa..bu e/ rkri.Jll,J, .v#.rc # aLF.rR erJ.ao•. lwam rxw w, y».a,.or.i._W-1 to. (-o o t•e{A.q Square Apartments - Building 3 Summary 20 -Dec -19 Ear ment Units Sq.Ft. I Basement I Level 1 Level 2 Unit Total Ratio Sq.Ft. Total 1 Bedroom 3-1.1 61 1 01 11 0 1 - COVER SHEET 611 1 Bedroom 3-1.2 760 0 U 1 1 BLDG 3 760 1 Bedroom Subtotal 700 2 90% 1371 2 Bedroom 3-2.1 806 0 5 5 10 - COVER SHEET 8060 2 Bedroom 3-2.2 700 0 0 2 2 BLDG 3 1400 2 Bedroom 3-2.3-A 700 0 2 0 2 A3-103 1400 2 Bedroom 3-2.4 789 0 21 2 4 LINE INDICATES 3156 2 Bedroom 3-2.5 770 2 01 0 2 BLDG 3 1540 2 Bedroom Subtotal BLDG 3 20 91%1 15556 Unit Totals 21 101 101 22 Unit Net Sq.Ft. 16927 ffTFFFFFFM_FFMTM_M� HUMN� UM" � � SIIF1 F F___F i w o®V HATCH INDIC, SCOPE OF W bUILDING 3 - SITE PLAN - EXISTING W. 48TH AVENUE 1" = 60'-0" L_ F71 11 1 1&76,1 1 1 1 1 0 LNC W. 48TH AVENUE BUILDING 3 - SITE PLAN - PROPOSED 1" = 60'-0" n PROJECT NARRATIVE: Caesar Square Apartments is a renovation project of 108 apartment units within 5 buildings located in Wheat Ridge, Colorado. This property is managed and maintained by Jefferson County Housing Authority as an affordable housing project in the Metro -Denver area. The buildings were originally built in the early 1970's, and have experienced minor renovations over the yars. The scope of this project includes site renovation, reconstruction and reconfiguration of the parking area, addition of site amenities, construction of a new construction community center, and renovation of the residential unit interiors and exteriors of the five existing apartment builings.The overall scope also includes adding accessibility for those with mobility impaiments. The new commnity building will be constructed as a fully accessible building, and buildings 2 and 3 will be renovated to allow for accessible entry to he buildings, as well as have unit modifie to comply with ANSI Type 'A' requirements. This set of documents in only a documentation of the renovation scope for building 3 wih scope items summarized below. BUILDING 3 RENOVATION SUMMARY: 1. EXTERIORS a. Repaint existing siding b. Reclad mansard roofs with metal C. Bring stairs / railings up to code d. Add exterior building signage e. Add exterior ramp on north side into building for accessibility. f. Add accessibility modifications at exterior of building. g. Replace exterior sliding windows with casement windows at Type 'A' units on level 1. 1. INTERIORS - UNITS L a. Asbestos abatement at floors & drywall at bathrooms b. Type 'A' Unit modifications C. Replace all new unit entry doors / hardware d. Replace all bath plumbing fixtures / accessories / shower valves e. Replace all kitchen cabinets / plumbing fixtures / appliances / accessories f. Replace all lighting g. Update electrical to code / pig -tailing aluminum wiring h. Repaint all unit interiors: walls / ceilings / shelving / sills / frames i. Replace all unit interior flooring 2. INTERIORS — CORRIDORS a. Replace all light fixtures b. Replace all interior stair railings C. Replace all unit entry doors & add new accessible signage d. Repaint all corridor walls / ceilings / trim e. Replace all corridor flooring f. Remove existing window and door at all exterior building entries and replace with aluminum storefront system IL1I11WX•1a11ZIAT jIL1[cl-� Sheet No. WHEAT RIDGE APPLICABLE CODES: E THESE PLANS WERE REVIEWED PER THE STANDARDS IN E THE CITY OF WHEAT RIDGE ADPOTED CODES AND E AMENDMENTS IN PLACE AT THE TIME OF APPLICAITON. E Sheet Name BUILDING 3 -ARCHITECTURAL A3-001 BLDG 3 - COVER SHEET A3-002 BLDG 3 - COVER SHEET A3-003 BLDG 3 - ENTERPRISE GREEN COMMUNITIES CHECKLIST A3-100 BLDG 3 - EXISTING FLOOR PLANS A3-101 BLDG 3 - EXISTING FLOOR PLANS A3-102 BLDG 3 - EXISTING ROOF PLAN A3-103 BLDG 3 - OVERALL DEMOLITION FLOOR PLANS A3-104 BLDG 3 - PROPOSED FLOOR PLANS A3-105 BLDG 3 LINE INDICATES A3-106 BLDG 3 -L A3-301 BLDG 3 - ENLARGED UNIT 3-1.1 PHASING PLAN ACCESSIBLE ROUTE BLDG 3 - ENLARGED UNIT 3-1.2 PHASHING PLAN A3-303 BLDG 3 - ENLARGED UNIT 3-2.1 PHASING PLAN A3-304 TO LAUNDRY ROOM - ENLARGED UNIT 3-2.2 PHASING PLAN A3-305 BLDG 3 - ENLARGED UNIT 3-2.3 PHASING PLAN A3-306 t t A3-307 BLDG 3 ' A3-308 BLDG 3 - ENLARGED UNIT 3-2.5 PHASING PLAN — BLDG 3 - ENLARGED UNIT 3-2.6 PHASING PLAN A3401 BLDG 3 - EXISTING EXTERIOR ELEVATIONS A3402 BLDG 3 - PROPOSED EXTERIOR ELEVATIONS A3-601 BLDG 3 - RAMP & RAILING DETAILS A3-602 BLDG 3 - RAILING DETAILS A3-603 BLDG 3 - DETAILS A3-604 BLDG 3 - DETAILS A3- BLDG 3 -WALL ASSEMBLIES & DETAILS A3-606 BLDG 3 - INTERIOR ACCESSIBILITY DETAILS A3-607 BLDG 3 - MOUNTING HEIGHTS & ACCESSIBILITY DETAILS A3-701 BLDG 3 - DOOR /WINDOW FRAME & TYPES AND SCHEDULES �N BLDG.3 -' W 9295 W 48TH AVE, w W 22 UNITS � � F W LINE INDICATES - ACCESSIBLE ROUTE TO TYPE'A' RESIDENT STORAGE W. 48TH AVENUE BUILDING 3 - SITE PLAN - PROPOSED 1" = 60'-0" n PROJECT NARRATIVE: Caesar Square Apartments is a renovation project of 108 apartment units within 5 buildings located in Wheat Ridge, Colorado. This property is managed and maintained by Jefferson County Housing Authority as an affordable housing project in the Metro -Denver area. The buildings were originally built in the early 1970's, and have experienced minor renovations over the yars. The scope of this project includes site renovation, reconstruction and reconfiguration of the parking area, addition of site amenities, construction of a new construction community center, and renovation of the residential unit interiors and exteriors of the five existing apartment builings.The overall scope also includes adding accessibility for those with mobility impaiments. The new commnity building will be constructed as a fully accessible building, and buildings 2 and 3 will be renovated to allow for accessible entry to he buildings, as well as have unit modifie to comply with ANSI Type 'A' requirements. This set of documents in only a documentation of the renovation scope for building 3 wih scope items summarized below. BUILDING 3 RENOVATION SUMMARY: 1. EXTERIORS a. Repaint existing siding b. Reclad mansard roofs with metal C. Bring stairs / railings up to code d. Add exterior building signage e. Add exterior ramp on north side into building for accessibility. f. Add accessibility modifications at exterior of building. g. Replace exterior sliding windows with casement windows at Type 'A' units on level 1. 1. INTERIORS - UNITS L a. Asbestos abatement at floors & drywall at bathrooms b. Type 'A' Unit modifications C. Replace all new unit entry doors / hardware d. Replace all bath plumbing fixtures / accessories / shower valves e. Replace all kitchen cabinets / plumbing fixtures / appliances / accessories f. Replace all lighting g. Update electrical to code / pig -tailing aluminum wiring h. Repaint all unit interiors: walls / ceilings / shelving / sills / frames i. Replace all unit interior flooring 2. INTERIORS — CORRIDORS a. Replace all light fixtures b. Replace all interior stair railings C. Replace all unit entry doors & add new accessible signage d. Repaint all corridor walls / ceilings / trim e. Replace all corridor flooring f. Remove existing window and door at all exterior building entries and replace with aluminum storefront system IL1I11WX•1a11ZIAT jIL1[cl-� Sheet No. WHEAT RIDGE APPLICABLE CODES: E THESE PLANS WERE REVIEWED PER THE STANDARDS IN E THE CITY OF WHEAT RIDGE ADPOTED CODES AND E AMENDMENTS IN PLACE AT THE TIME OF APPLICAITON. E Sheet Name BUILDING 3 -ARCHITECTURAL A3-001 BLDG 3 - COVER SHEET A3-002 BLDG 3 - COVER SHEET A3-003 BLDG 3 - ENTERPRISE GREEN COMMUNITIES CHECKLIST A3-100 BLDG 3 - EXISTING FLOOR PLANS A3-101 BLDG 3 - EXISTING FLOOR PLANS A3-102 BLDG 3 - EXISTING ROOF PLAN A3-103 BLDG 3 - OVERALL DEMOLITION FLOOR PLANS A3-104 BLDG 3 - PROPOSED FLOOR PLANS A3-105 BLDG 3 - PROPOSED FLOOR PLANS A3-106 BLDG 3 - PROPOSED ROOF PLAN A3-301 BLDG 3 - ENLARGED UNIT 3-1.1 PHASING PLAN A3-302 BLDG 3 - ENLARGED UNIT 3-1.2 PHASHING PLAN A3-303 BLDG 3 - ENLARGED UNIT 3-2.1 PHASING PLAN A3-304 BLDG 3 - ENLARGED UNIT 3-2.2 PHASING PLAN A3-305 BLDG 3 - ENLARGED UNIT 3-2.3 PHASING PLAN A3-306 BLDG 3 - ENLARGED UNIT 3-2.4 TYPE A PHASING PLAN A3-307 BLDG 3 - ENLARGED UNIT 3-2.4 TYPE A PHASING PLAN A3-308 BLDG 3 - ENLARGED UNIT 3-2.5 PHASING PLAN A3-309 BLDG 3 - ENLARGED UNIT 3-2.6 PHASING PLAN A3401 BLDG 3 - EXISTING EXTERIOR ELEVATIONS A3402 BLDG 3 - PROPOSED EXTERIOR ELEVATIONS A3-601 BLDG 3 - RAMP & RAILING DETAILS A3-602 BLDG 3 - RAILING DETAILS A3-603 BLDG 3 - DETAILS A3-604 BLDG 3 - DETAILS A3- BLDG 3 -WALL ASSEMBLIES & DETAILS A3-606 BLDG 3 - INTERIOR ACCESSIBILITY DETAILS A3-607 BLDG 3 - MOUNTING HEIGHTS & ACCESSIBILITY DETAILS A3-701 BLDG 3 - DOOR /WINDOW FRAME & TYPES AND SCHEDULES CITY OF WHEAT RIDGE APPLICABLE CODES: E THESE PLANS WERE REVIEWED PER THE STANDARDS IN E THE CITY OF WHEAT RIDGE ADPOTED CODES AND E AMENDMENTS IN PLACE AT THE TIME OF APPLICAITON. E EXISTING E APPLICABLE CODES: 2018 INTERNATIONAL BUILDING CODE (IBC) E 0 2018 INTERNATIONAL MECHANICAL CODE (IMC) 0 2018 INTERNATIONAL ENERGY CONSERVATION CODE E 3 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) E 2 2018 INTERNATIONAL FIRE CODE E 0 2018 INTERNATIONAL PROPERTY MAINTENANCE CODE 5 2018 INTERNATIONAL EXISTING BUILDING CODE 0 2018 NATIONAL ELECTRICAL CODE (NEC) STUDIO 646 ARCHITECTURE, LLC 2018 INTERNATIONAL PLUMBING CODE (IPC) 15940 S. GOLDEN ROAD 2018 INTERNATIONAL FUEL GAS CODE (IFGC JURISDICTION: BUILDING CODE AGENCY ......... City of WHEAT RIDGE 303.284.1276 FIRE DEPARTMENT ....................ARVADA FIRE PROTECTION DISTRICT DEVELOPER PLANING / ZONING ....................City of WHEAT RIDGE PLANING DEPARTMENT JEFFERSON COUNTY WATER ........................................City of WHEAT RIDGE (VALLEY WATER) HOUSING AUTHORITY SANITARY SEWER......................City of WHEAT RIDGE (CLEAR CKEEK VALLEY) 7490 W 45TH AVENUE ELECTRIC ..................................... XCEL ENERGY WHEAT RIDGE, CO 80033 NATURAL GAS............................. XCEL ENERGY 2018 IEBC CODE ANALYSIS The majority of work on this project will fall under the 2018 IEBC and the definition for "Repairs" as defined in chapter 2. The compliance path is as follows: 301.1.2: Work area compliance method: Repairs, alterations, additions, changes in occupancy and relocated buildings complying with the applicable requirements of Chapters 5 –13 of this code shall be considered in compliance with this code. Notes: Majority of documented work in this building can be described as a replacement of interior finishes. There are some instances of the building being upgraded for greater compliance with code for safety reasons. For example, railings are being replaced with code compliant railings, but these instances are minimal. The contractor has been instructed where possible to leave wall, ceiling, drywall assemblies in place in order to not disturb the existing rated assemblies. Therefore, we will be following the requirements based on the definition of alterations, and will fall under the requirements of IEBC Chapter 7 Alternations – Level 1 Work will be in compliance with Section 701 Work will be in compliance with Section 702 702.4 – Materials and Methods Notes: We dont anticipate any work to the building plumbing /mechanical systems outside of replacing fixtures and appliances consistent with normal maintenance. Work will be in compliance with Section 704 Fire Protection Notes: The current level of fire protection will be maintained. Work will be in compliance with Section 705 Accessibility Notes: Due to a measurable amount of asbestos in the drywall texture, all alterations and repairs are being completed in a manner that will not disturb the asbestos. All drywall will remain in place to the extent possible. Because of this, accessibility improvements have been evaluated considering the entire site, and in order to minimize construction costs alterations related to accessibility have been isolated to 2 of the 5 residential buildings on site, as well as the construction of a new fully accessible community building with public facilities included. The 2 buildings with accessibility improvements will have accessible entrances, and units complying with ICC ANSI A117.1 requirements for Type A residential units. For each building to be fully accessible compliant is technically infeasible as these buildings were constructed prior to any accessibility requirements being in place. Work will be in compliance with Section 706 Structural Notes: We dont anticipate any structural work to the building. Work will be in compliance with Section 707 Energy Conservation Notes: The only alterations are the replacement of the entry windows and doors. These will comply with current IECC requirements. New storefront at the building entry points will be a minimum if U 0.32. 3-802 BLDG 3 - ENLARGED CORRIDOR CEILING PLANS 3-803 BLDG 3 - INTERIOR CORRIDOR ELEVATIONS 3-804 BLDG 3 - UNIT INTERIOR ELEVATIONS 3-805 BLDG 3 - UNIT INTERIOR ELEVATIONS 3-806 BLDG 3 - UNIT INTERIOR ELEVATIONS 3-807 BLDG 3 - UNIT INTERIOR ELEVATIONS UILDING 3 -STRUCTURAL 3-100 BUILDING 3 -GENERAL NOTES AND SECTIONS 3-101 BLDG 3 - FLOOR PLANS 3-101 D BLDG 3 - DEMO PLANS UILDING 3 - PLUMBING 3-000 BUILDING 3 - PLUMBING SYMBOLS, NOTES, LEGENDS, SCHEDULES 3-100 BUILDING 3 - PLUMBING SITE NOTES 3-200 BUILDING 3 - TYPE A UNIT PLUMBING PLAN UILDING 3 - ELECTRICAL 3-000 BUILDING 3 - ELECTRICAL SYMBOLS, NOTES, LEGENDS, SCHEDULES 3-100 BUILDING 3 - BASEMENT ELECTRICAL PLAN 3-101 BUILDING 3 - LEVEL 1 ELECTRICAL PLAN 3-102 BUILDING 3 - LEVEL 2 ELECTRICAL PLAN 3-200 BUILDING 3 - TYPE A UNIT ELECTRICAL PLANS 3-201 BUILDING 3 - ENLARGED ELECTRICAL UNIT PLANS 3-300 BUILDING 3 - COMMON AREA INTERIOR LIGHTING 3-301 BUILDING 3ACCESSIBLE UNITS: BUILDING ACCESSIBLE UNITS EXISTING PROPOSED 1 0 0 2 0 3 3 0 2 4 0 0 5 0 0 TOTAL: 5 F- ASSOCIATED DOCUMENTS: CONSTRUCTION DOCUMENTS: 'CAESAR SQUARE - RENOVATION' OVERALL SITEWORK RENOVATION PLAN SET GEOTECHNICAL REPORT Z TERRACON GEOREPORT PROJECT NO.: 25195383 2J JANUARY 22, 2020 na/ PROJECT TEAM ARCHITECT CIVIL ENGINEER ERIC BLASE ROBERT PALMER STUDIO 646 ARCHITECTURE, LLC STRATEGIC LAND SOLUTIONS, INC. 15940 S. GOLDEN ROAD 2595 PONDEROSA ROAD GOLDEN, CO 80401 FRANKTOWN, CO. 80116 303.284.1276 720.384.7661 DEVELOPER SURVEYOR JEFFERSON COUNTY CHARLES BECKSTROM HOUSING AUTHORITY ENGINEERING SERVICE COMPANY 7490 W 45TH AVENUE 14190 E EVANS AVENUE WHEAT RIDGE, CO 80033 AURORA, CO 80014 303.422.8600 303.337.1393 GENERAL CONTRACTOR STRUCTURAL ENGINEER TAYLOR KOH RS CRAIG CARROLL 12160 PENNSYLVANIA ST. MONROE & NEWELL ENGINEERS, INC. THORNTON, CO. 80241 1400 GLENARM PL, SUITE 100 303.928.1800 DENVER, CO 80202 303.892.5980 303.623.4927 LANDSCAPE ARCHITECT MEP TOM KLEIN BELFAY ENGINEERING TICK DESIGN & PLANNING 2811 W 9TH AVE 2809 LARIMER ST. DENVER, CO. 80204 DENVER, CO. 80205 303.892.5980 720.242.7947 0 a F- a 2 LU Z 2J na/ O0 J_ z�c(D U U • �--� o ° O O F O M C) O T OMM 'i \"LU J LU 0 0 wED W W ( vW O 9 m F -Z z LU 5 ¢ 0 w tj co 0 a o oM N 'M 19-016 <1 DOM NO. 0 0 0 0 �N PLAN DATES a Z na/ O0 J_ z�c(D U LU 0 N • �--� o ° W O w o M C) O T OMM 'i \"LU J A3-001 Z J_ m OMM 'i \"LU J 0 LLI � DO W ( vW O C/5��/) V J Q LU W > 0 LU< co C) N 'M 19-016 SHEET NO. A3-001 ABBREVIATIONS ABBREVIATIONS ABBREVIATIONS GRAPHIC STANDARDS GENERAL UNIT ACCESSIBILITY NOTES GENERAL RENOVATION NOTES 1. The term Ownershall denote the client, or Owner, as designated in the Contract. The # POUND(S) or NUMBER FHC FIRE HOSE CABINET PV. PAVEMENT , View Name DRAWING TITLE GENERAL: "Owner" g S & AND FIN. FINISH(ED) PWD PLYWOOD 1/8" = 1'-0" SCALE 1. EXISTING DOOR ROUGH OPENINGS TO REMAIN FOR DOOR REPLACEMENT term "General Contractor" or "Contractor" shall denote the Corporation, Company, < ANGLE FIXT FIXTURE U.N.O. RE: ACCESSIBLE UNIT NOTES (TYPE A) Partnership, Form or Individual who has entered into the Contract for the performance of BUILDING SECTION 2. DOOR LOCKS AND DOOR HARDWARE SHALL BE LOCATED AT THE ENTRY the work and has engaged Subcontractors to perform a part of the work. The term @ AT FL FLOORING) Q.T. QUARRIED TILE DOORS AT A HEIGHT NO HIGHER THAN 48" A.F.F. LEVER DOOR HARDWARE "Architect" refers to Studio 646 Architecture, LLC.". FLG FLASHING DIRECTION OF SIGHT A MEDICAL AIR FLUR FLUORESCENT R&S RESILIENT 1 IM DRAWING NUMBER REQUIRED AT EXTERIOR FACE OF DOOR. 2. The use of the words "provide" and "provided" in connection with any item specified shall 3. CHANGES IN LEVELWITHIN THE DWELLING UNIT THAT ARE BETWEEN 1/4" be intended to mean that the item shall be furnished, installed and connected where so A/C AIR CONDITIONING FRP FIBERGLASS REINFORCED PANEL(ING) R. RISER A101 SHEET NUMBER AND 1/2" ARE TO BE BEVELED WITH A SLOPE NOT EXCEEDING 1:2. CHANGE INAB ANCHOR BOLT FT. FEET R.D. ROOF DRAIN LEVEL GREATER THAN 1/2" ARE TO BE RAMPED. THRESHOLDS AT EXTERIORrequired. ABV ABOVE FTG FOOTING R. F. RESILIENT FLOORING WALL SECTION DOORS NOT TO EXCEED 1/2". EXTERIOR SLIDING DOOR TRACKS NOT TO 3. All dimensions are taken to face of stud, grid centerlines, or face of masonry unless EXCEED 3/4" WHERE ACCESS TO EXTERIOR PATIO IS APPLICABLE AC ACCOUSTICAL FURR FURRING R. L. RAIN LEADER DIRECTION OF SIGHT otherwise noted. Y ACT ACCOUSTICAL CEILING TILE FUT FUTURE R. 0. ROUGH OPENING SIM 4. THE LANDING AT THE PRIMARY ENTRY DOOR IS TO BE NO MORE THAN 1/2" � 1 DRAWING NUMBER BELOW INTERIOR FINISH FLOOR. EXTERIOR LANDINGS MAY BE SLOPED AT 4. DO NOT scale drawings. Dimensions govern. Large scale details govern over small ADD ADDENDUM R.O.D. ROOF OVERFLOW DRAIN A101 1/8" PER FOOT FOR DRAINAGE. g g g g _ SHEET NUMBER -. �. ADJ ADJACENT orADJUSTABLE G.B. GRAB BAR R.W.C. RAIN WATER CONDUCTOR 5. EXTERIOR DECK, PATIO, OR BALCONY SURFACES ARE NOT TO BE 1/2" scale. oQ AFF ABOVE FINISHED FLOOR GA. GAUGE RAD. RADIUS BELOW INTERIOR FINISH FLOOR UNLESS THEY ARE CONSTRUCTED OF Z DETAIL CUT IMPERVIOUS MATERIAL SUCH AS CONCRETE, IN WHICH CASE, IT CAN BE 4" 5. Notify Architect immediately should conditions be found contradictory to these drawings. oz AG AGGREGATE GALV GLAVANIZED RE. REFER TO or REFERENCE DIRECTION OF SIGHT BELOW THE FINISH FLOOR AHU AIR HANDLING UNIT GCMU GLAZED CONCRETE MASONRY UNIT(S) REC RECESS(ED) SIM 6. The Drawings and Specifications are supplied to illustrate the design intent and the �o AL ALUMINUM GD. GRADE REFR REFRIGERATOR or REFRIGERATED 1 DRAWING NUMBER 6. FRONT LOADING WASHER AND DRYER, DOOR TO LAUNDRY COMPARTMENT g type q y quality 15" MIN. -36" MAX ABOVE FLOOR general t e of construction required. The are intended to implythe finest of QI ALT ALTERNATE GL. GLASS or GLAZING REINF REINFORCED A101 SHEET NUMBER construction, material and workmanship. APSH ASPHALT GND GROUND REQ. REQUIRED BATHROOMS: 7. Drawings and general notes are complementary, and what is called for by one will be APX APPROXIMATE(LY) GWB GYPSUM WALLBOARD REV REVISE, REVISED or REVISION SIM 1WALL DIMENSIONS AND FIXTURE LOCATIONS MUST BE HELD SO THAT THE binding as if called for by all. Work shown or referred to on any drawing shall be V I ARCH ARCHITECTURAL GYP. GYPSUM RFG. ROOFING 1 . completed as though shown on all related drawings. '1 MINIMUM CLEARANCES ARE PROVIDED AS INDICATED ON THE PLAN. A ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS GYP. BD. GYPSUM BOARD RFL. REFLECTED A101 DETAIL CALLOUT CLEAR FLOOR SPACE OF 30"X48" SHALL BE PROVIDED WITHIN THE xx AUTO AUTOMATIC RM. ROOM BATHROOM EXCLUSIVE OF THE DOOR SWING. 8. The character and scope of work are described by the drawings and notes contained >� H.C. HOLLOW CORE 2. PROVIDE 2X WOOD BLOCKING IN LINE OF STUD FOR WALLS NOTED AS herein. Additional drawings and information deemed necessary by the Architect to Lu B. 0. BY OWNER H.M. HOLLOW METAL S. SOUTH REQUIRING REINFORCING FOR FUTURE INSTALLATION OF GRAB BARS AS interpret and/or explain drawings, specifications or notes previously issued shall be Ir NOTED IN PLANS. FOR INFORMATION ON BLOCKING LOCATIONS. provided to the General Contractor. It shall be understood that such additional drawings B.O.F. BY OWNER, FUTURE HDCP HANDICAP(PED) S.C. SOLID CORE ` J and information shall be considered part of the Contract Documents. BD BOARD HDW HARDWARE S.C.D. SEAT COVER DISPENSER EXTERIOR ELEVATION 3. ALL TUB AND SHOWER SURROUNDS SHALL COME WITH INTEGRAL BLOCKING FOR FUTURE INSTALLATION OF GRAB BARS. SEE DIAGRAM FOR REQUIRED g If there are any questions regarding the Contract Documents, existing conditions or BEL BELOW HOR HORIZONTAL S. D. SOAP DISPENSER DIRECTION OF SIGHT GRAB BAR LOCATIONS. BET BETWEEN HR HOUR S.N.C. SANITARY NAPKIN CABINET 1 DRAWING NUMBER 4. LAVATORIES ARE TO BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE design intent, the Contractor shall obtain a clarification from the Owners Representative BIT BITUMINOUS HT HEIGHT S.N.D. SANITARY NAPKIN DISPENSER A MINIMUM OF 1'-3" HORIZONTALLY FROM AN ADJOINING WALL OR FIXTURE. or Architect prior to proceeding with the work in question. Lu A10 SHEET NUMBER w BKT BRACKET HVAC HEATING, VENTILATION and AIR S.N.R. SANITARY NAPKIN RECEPTACLEKITCHENS: 10. All work performed and material installed shall be, as a minimum standard, in strict Z p BLDG BUILDING CONDITIONING S. R. SINK RECEPTACLE conformance with the latest editions of all general codes, regulations and ordinances O O BLKG BLOCKING SCHED SCHEDULE INTERIOR ELEVATION including the building code. The Contractor shall give all notices and comply with all laws, a Lu o B.C. INTERNATIONAL BUILDING CODE or 1 1. PROVIDE A MINIMUM CLEAR DIMENSION OF 40" BETWEEN ANY WALL AND ordinances, rules, regulations and lawful orders of any public authority having jurisdiction BLT BORROWED LIGHT SEC SECTION DIRECTION OF SIGHT BASE CABINET OR APPLIANCE O ¢ BM BEAM INSTALLED BY CONTRACTOR SF SQUARE FEET 4 2. CLEAR FLOOR SPACE OF 30" X 52" REQUIRED WITHIN KITCHEN TO ALLOW over the performance of the work. U o A101 DRAWING NUMBER Lu a_ BOT, BOTTOM D. INSIDE DIAMETER SH. SHELF 2 PARALLEL APPROACH TO APPLIANCES AND FIXTURES. .INCH SHEET NUMBER 3. WHERE NOTED ON UNIT PLANS: PROVIDE 30" WORKSPACE w/ REMOVABLE 11. Contractor is responsible for all work shown, noted, specified, or reasonably inferred from BRG BEARNING SHR SHOWER 3CABINETRY; EXTEND FLOOR TO WALL; PAINT AND FINISH WALL the construction documents. N BSMT BASEMENT NFO INFORMATION 0 SHT SHEET o NS. NSULATION or INSULATED 4. COMBINATION REFRIGERATOR & FREEZER WITH 50 /o OF FREEZER 12. The General Contractor upon acceptance of the drawings and specifications assumes w SHTG SHEATHING COMPARTMENT SHELVES SHALL BE 54" MAX ABOVE FLOOR C.C.D. CONSTRUCTION CHANGE DIRECTIVE INT INTERIOR SIM SIMILAR - - 5. WHERE NOTED ON UNIT PLANS: SINK TO HAVE REMOVABLE CABINETRY; full responsibility for the construction, materials and workmanship of the work, and shall oNo C.G. CORNER GUARD INTX INTERSECTION SPEC SPECIFICATION(S) 00.0 00.0 COLUMN CENTERLINE EXTEND FLOORING TO WALL, PAINT AND FINISH WALL, INSULATE PIPES FOR comply with the spirit as well as the letter of that which is contained therein. REFERENCE GRID & BUBB E SINK PLAN DATES C.J. CONTROL JOINT SQ. SQUARE 6. WHERE NOTED ON UNIT PLANS: RANGE TO HAVE CONTROLS AT THE FRONT 13. The scope si work described cr the Contract Documents implies i completed project. r 1 C.L.L. CONTRACT LIMIT LINE JAN. JANITOR SSK SERVICE SINK Minor omissions from and discrepancies in the drawings and specifications shall not void JT. JOINT 00.0 OF THE UNIT such intention. The Contractor shall inform the Architect in writing of any conflicts, a C.O. CHANGE ORDER SST STAINLESS STEEL C.S.S. CLINICAL SERVICE SINK STA STATION TCLOSETS: omissions and discrepancies prior to construction. C.T. CERAMIC TILE K. D. KNOCKDOWN STD STANDARD 1 14. The General Contractor shall obtain all required building permits. a CAB. CABINET K.O. KNOCKOUT STL STEEL 1. WALK-IN CLOSETS: AT LEAST ONE CLOTHES ROD SHALL BE MOUNTED NOT W 00.0 HIGHER THAN 54" A.F.F. OR PROVIDE AN ADDITIONAL CLOSET ROD. O 00 CATV CABLE TELEVISION KIT KITCHEN STO STORAGE 15. The General Contractor shall obtain all special inspection required by the authority KPL KICK PLATE Tv 2. CLOSETS LESS THAN 25" IN DEPTH: PROVIDE SPACE AND/OR BRACKETS FOR having jurisdiction over the project. z < CCTV CLOSED CIRCUIT TELEVISION STIR STRUCTURE or STRUCTURAL 91 p 1 RE -LOCATION OF RODS HIGHER THAN 54" A.F.F. CEM CEMENT SUSP SUSPEND(ED) O 0 O N LAB LABORATORY 16. The General Contractor shall supervise and direct the work using his best skill and Q CFL COUNTERFLASHING SYM SYMMETRICAL ELECTRICAL: r..4 00 v LAM LAMINATE ROOM TAG 1. LIGHT SWITCHES, THERMOSTATS, AND OTHER ENVIRONMENTAL CONTROLS attention. He shall be solely responsible for all construction means, methods, techniques, • � U Q O CK CAULKING) SYS SYSTEM sequences and procedures. He shall coordinate all portions of the work under theW O z 0 CL CENTERLINE LAV LAVATORY Room name -NAME MUST BE POSITIONED SUCH THAT CONTROL ARE LOCATED NOT HIGHER Contract. o Lu M CLG CEILING LBL LABEL T&G TONGUE AND GROOVE NUMBER THAN 48" A.F.F. ELECTRICAL OUTLETS, PHONE AND CABLE T.V. JACKS MUST BE MOUNTED SUCH THAT THE MINIMUM HEIGHT IS 15" A.F.F. SWITCHES, F-�---I rn 0 LKR LOCKER 17. General Contractor and subcontractors shall visit the project, as required by the h� Lb 0 CLO. CLOSET T. TREAD or TELEPHONE SQUARE FOOTAGE CONTROLS, AND/OR OUTLETS ABOVE KITCHEN OR BATHROOM CLR CLEAR LLH LONG LEG HORIZONTAL T. B. TOWEL BAR COUNTERTOPS SHALL NOT EXCEED 44" A.F.F. specifications, to become familiar with all existing conditions affecting the proposed r 1 LLV LONG LEG VERTICAL demolition and new construction prior to submittal of bids. 4-1 CMU CONCRETE MASONRY UNIT T. 0. TOP OF J CNTR COUNTER LT LIGHT T.P.D. TOILET PAPER DISPENSER r PARTITION OR WALL TYPE 18. The General Contractor shall perform high-quality professional work. Materials shall be COL COLUMN LTL LINTEL TEL TELEPHONE 88a ACCESSIBLE UNIT NOTES (TYPE A) joined to uniform, accurate fits so that they meet in neat, straight lines free of smears or LVR LOUVER RATED CONC CONCRETE THK THICK or THICKNESS overlaps. Exposed materials shall be installed appropriately level, plumb and at accurate ACOUSTIC right angles to or flush with adjacent materials. The work of each trade shall meet all pbotlq CONN. CONNECTION THR THRESHOLD GENERAL: sP National Standards published by the trade, except where the requirements of the Contact a° °tea � M.O. MASONRY OPENING '°N CONST CONSTRUCTION TPTN TOILET PARTITION NUMBER 1. MAXIMUM THRESHOLD HEIGHT SHALL NOT BE GREATER THAN 1/2" Document are more stringent. MAS MASONRY CONT CONTINUOUS TV TELEVISION 2. SHELVES IN LINEN OR PANTRY SHALL BE 9" MIN. AND 54" MAX. ' CONTR CONTRACT(OR) MAT MATERIAL TYP TYPICAL 19. The presence of an architectural representative on the jobsite does not imply MAX MAXIMUM 3. DOORS INTO AND WITHIN APPLICABLE DWELLING UNITS SHALL PROVIDE FOR A CORR CORRIDOR TZ TERRAZZO DOOR NUMBER CLEAR OPENING WIDTH OF 32" AND 34" MIN WIDE. CORRIDORS SHALL HAVE A concurrence cf approval of the work. The Contractor shall call to the attention of the CPT CARPET MECH MECHANICAL 1t MINIMUM CLEAR WIDTH OF 36" AND MINIMUM CLEAR HEADROOM OF 80" Architect specific items for which he desires to obtain approval. Gi707ry9 D Co MEP MECHANICAL, ELECTRICAL and PLUMBING CTR CENTER U. L. UNDERWRITER'S LABORATORY WINDOW FRAME TYPE 20. The General Contractor shall correct defects in material and workmanship noted by the CTSK COUNTERSINK MFR MANUFACTURER U.N.O. UNLESS NOTED OTHERWISE 1i GLAZING TYPE TAG Architect during periodic site observations and at project close-out. MIN MINIMUM U.O.S. UNLESS OTHERWISE SPECIFIED BATHROOMS: D. DRAIN or DATA MIR. MIRROR UNF. UNFINISHED O 21. The General Contractor shall turn the project over to the Owner free from all construction co MISC MISCELLANEOUS 1. WATER CLOSET HEIGHT SHALL BE 15"MINIMUM TO 19" MAXIMUM MEASURED TO D. F. DRINKING FOUNTAIN UR. URINAL TOP OF TOILET SEAT. debris, scraps, materials and equipment; with all interior glass free from manufacturer's MMB MEMBRANE labels and tape and clean on both sides; with all doors built-in millwork wiped down and D.S. DOWNSPOUT A3 TOILET ACCESSORY TAG 2. GRAB BARS SHALL BE 1-1/4" TO 1-1/2" IN DIAMETER WITH 1-1/2" BETWEEN WALL AND free of dirt, grease and other foreign material. DBL DOUBLE V VACUUM z MT. MOUNT(ED) GRAB BAR. MTL METAL V.B. VAPOR BARRIER KEYNOTE DESIGNATION 3. GRAB BARS TO BE MOUNTED AT 33" MINIMUM TO 36" MAXIMUM AS SHOWN ON DEPT DEPARTMENT PLANS U.N.O. DET DETAIL MUL MULLION V.I.F. VERIFY IN FIELD OQ 4. GRAB BARS, WHEN INSTALLED, SHALL SUPPORT A WEIGHT OF 250 LBS AT ANY DIA DIAMETER VCT VINYL COMPOSITION TILE REVISION DELTA POINT ALONG THE BAR. GENERAL DEMOLITION NOTES J DIM DIMENSION (N) NEW VERT VERTICAL A� 5. TOILET PAPER DISPENSER TO BE MOUNTED 8" IN FRONT OF THE WATER CLOSET, _ DN DOWN N NORTH VEST VESTIBULE BETWEEN 15" AND 48" ABOVE THE FLOOR AND 1-1/2" ABOVE OR 12" BELOW A GRAB 1. CONTRACTOR SHALL VERIFY WITH OWNER ALL ITEMS IDENTIFIED TO BE SALVAGED N.I.C. NOT IN CONTRACT BAR AND STORED FOR REUSE PRIOR TO COMMENCING WITH WORK. DPR DISPENSER VIN VINYL Name VERTICAL ELEVATION 6. MEDICINE CABINET SHALL BE LOCATED WITH A USEABLE SHELF AT 44" MAXIMUM DR DOOR N.T.S. NOT TO SCALE VTR VENT TO ROOF Elevation DATUM NO. NUMBER A.F.F. 2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS SHOWN DWG DRAWING VWC VINYL WALL COVERING 7. BOTTOM OF MIRROR SHALL BE 38" MAXIMUM A.F.F. ON DEMOLITION PLANS AND NOTIFY ARCHITECT IMMEDIATELY IF THERE ARE ANY DWR DRAWER NOM. NOMINAL NORTH ARROW 8. A REMOVABLE IN -TUB SEAT SHALL BE PROVIDED. DISCREPANCIES. W WEST N 9. PROVIDE SINGLE LEVER WATER CONTROL. (E) EXISTING 02 OXYGEN W.C. WATER CLOSET 10. PROVIDE A SHOWER SPRAY UNIT WITH A 60" HOSE MINIMUM, THAT CAN BE USED AS 3. ALL ITEMS INDICATED AS DASHED ON DEMOLITION PLANS ARE TO BE REMOVED IN UJ O.A. OVERALL A FIXED OR HAND HELD SHOWER. THEIR ENTIRETY. PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED FOR E. EAST W.PT. WORKING POINT 11. PROVIDE MINIMUM CLEAR FLOOR SPACE FOR FIXTURES AS INDICATED IN PLANS. 0. C. ON CENTER INSTALLATION OF NEW FINISHES. M E. D. EXHAUST DUCT W. R. WATER RESISTANT 12. PROVIDE MINIMUM CLEAR KNEE SPACE AS INDICATED IN INTERIOR ELEVATIONS. (7 E. H. EXHAUST FAN 0. D. OUTSIDE DIAMETER W.W.F. WELDED WIRE FABRIC GRAPHIC SCALE 13. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED TO PROTECT AGAINST 4. ALL SALVAGED AND STORED MATERIALS FOR RE -USE ARE THE GENERAL Q 0 LLI E.J. EXPANSION JOINT 0. H. OPPOSITE HAND W/ WITH 0' CONTACT. SEE DRAWING FOR CLEARANCE DIMENSIONS. CONTRACTOR'S RESPONSIBILITY TO PROTECT, REINSTALL, AND CLEAN. 0 w .. - E.O.S. EDGE OF SLAB W/O WITHOUT OT.OOUTSIDE-TO-OUTSIDE 14. FINISHED FLOORING SHALL EXTEND UNDER THE COUNTER TO THE WALL AT EACH DO OFF. OFFICE LINE SYMBOLS CLEAR FLOOR SPACE. 5. WHERE EXISTING ELEMENTS ARE INDICATED TO REMAIN AND ARE LOCATED ON OR = E.W.C. ELECTRIC WATER COOLER WB WASTE BASKET 15. GRAB BARS TO BE PRE-INSTALLED BY TUB & SHOWER SURROUND MFR @ ALL TYPE ADJACENT TO EXISTING CONSTRUCTION TO BE REMOVED, THESE ELEMENTS TOO C/). OPGOPENING EA. EACH WD WOOD A UNITS BE SALVAGED FOR RE -INSTALLATION AT NEW CONSTRUCTIONw . U EL. ELEVATION OPP. OPPOSITE WF. WIDE FLANGE 16. CONTRACTOR TO PROVIDE GRAB BARS FOR TOILETS AT ALL TYPE A UNITS. DO NOT � > .. ELEC. ELECTRICAL WIN WINDOW CENTER LINE INSTALL. SEE DIAGRAM FOR REQUIREMENTS. 6. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL Q W LJJ ELEV. ELEVATOR P.A.C. PREVIOUSLY AWARDED CONTRACT WP WATERPROOF(ING) 17. 34" TALL VANITY w/ REMOVABLE CABINETRY EXTEND FLOORING TO WALL, PAINT DEMOLITION THAT MAY NOT BE INDICATED ON ARCHITECTURAL DRAWINGS BUT IS I..L _ (� i EM. EMERGENCY OUTLET P. L. PROPERTY LINE WSCT WAINSCOT AND FINISH WALL, INSULATE PIPES FOR SINK REQUIRED TO INSTALL DUCT WORK, PIPING, CONDUIT, ETC. PATCH AS REQUIRED. LC'L/ Q O EMER. EMERGENCY P. R. PROPOSAL REQUEST GRID LINE KITCHENS: \ U P.T. POST TENSIONED SLAB 7. NO EXISTING BUILDING ELEMENTS SHALL BE REMOVED IN WHOLE OR IN PART ENGR. ENGINEER UNLESS OTHERWISE NOTED ON THE DRAWINGS. SHOULD IT BE NECESSARY TO r P.T.D. PAPER TOWEL DISPENSER EQ. EQUAL 1. ALL KITCHEN COUNTERTOPS SHALL BE 34" MAXIMUM. REMOVE AN ITEM NOT SCHEDULED FOR DEMOLITION IN ORDER TO COMPLETE THEUJ> Q M 2. PROVIDE MINIMUM CLEAR FLOOR SPACE FOR FIXTURES AND APPLIANCES AS P. T. D. R. PAPER TOWEL DISPENSER AND RECEPTACLE EQP EQUIPMENT WORK DESCRIBED HEREIN, THE GC SHALL NOTIFY THE ARCHITECT AND EXP. EXPANSION P.T.R. PAPER TOWEL RECEPTACLE PROPERTY LINE INDICATED ON PLANS. STRUCTURAL ENGINEER PRIOR TO COMMENCING WITH WORK. EXISTING BUILDING Lid w EXT EXTERIOR PFB. PREFABRICATED 3. THE DEPTH OF AT LEAST ONE BOWL AT THE KITCHEN SINK SHALL BE 6-1/2" ELEMENTS INCLUDE BUT ARE NOT LIMITED TO FLOORS, WALLS, CEILINGS, 0 = Q PL. PLATE MAXIMUM. COLUMNS, AND BEAMS. 0'M m PLAM PLASTIC LAMINATE 4. FINISHED FLOORING SHALL EXTEND UNDER THE COUNTER TO THE WALL AT EACH F.B.O. FURNITURE BY OWNER CUT LINE 5. CLEAR FLOOR SPACE. 8. SHADED AREAS ON THE RELECTED CEILING PLAN INDICATE AREA WHERE EXISTING F. D. FLOOR DRAIN PLAS PLASTER 6. PROVIDE LEVER HARDWARE AT KITCHEN FAUCET. CEILING GRID IS TO BE REMOVED AND REPLACED. F. E. FIRE EXTINGUISHER PNL PANEL 7. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED TO PROTECT AGAINST 19-016 F. R. FIRE RESISTIVE PNTD PAINTED CONTACT. 9. ALL INCIDENTAL ITEMS NOT CONSISTENT WITH NEW WORK SHALL BE REMOVED PLAN MATCH LINE 8. A DISHWASHER SHALL BE PROVIDED TO ACCOMMODATE 34" COUNTER IN THE 2- FROM WALLS AND CEILINGS RECEIVING NEW FINISH. SEE DEMOLITION PLANS FOR F.R.T. FIRE RETARDANT TREATED PR. PAIR BDRM UNIT SPECIFIC INFORMATION. SHEET NO. FACP FIRE ALARM CONTROL PANEL PROJ PROJECT 9. CONTROLS FOR THE RANGE SHALL NOT REQUIRE REACHING ACROSS BURNERS. FAS. FASTEN(ER) PSF POUNDS PER SQUARE FOOT 10. BOTTOM OF WALL CABINETS SHALL NOT EXCEED 48" A.F.F. 10. ALL EXISTING CONCRETE SLAB TO BE REMOVED SHALL BE SAW CUT. FDN FOUNDATION PSI POUNDS PER SQUARE INCH A3-002 FEC FIRE EXTINGUISHER CABINET PT. PAINT or PAPER TOWEL CLOSETS: 11. REFERENCE ARCHITECTURAL DRAWINGS FOR ADDITITIONAL DEMOLITION FFL FINISHED FLOOR LINE PTN. PARTITION 1CLOSET SHELVING SHALL BE MOUNTED AT A MAXIMUM OF 54" A.F.F. INFORMATION ON EXISTING BUILDING NOT INDICATED ON DEMOLITION DRAWINGS. . 2 MINIMUM 20" DOOR AT ALL CLOSETS 24" DEEP OR SHALLOWER. 12. VERIFY IN FIELD: DRAINS OPERATING AND NOT CLOGGED BY DEBRIS, ETC. a N (`� O N O N r N V I r_ tel- n 11 i A3-401 EXISTING LEVEL 2 FLOOR PLAN u 1/811 = 1'-0" A3-401 I EXISTING LEVEL 1 FLOOR PLAN 1/811 = 1'-0" !Y !Y <2 3-401 hK Cp�o ERIC C o L U) 0 C) 0 LU Q 0 a N O N 74 PLAN DATES / Pbbott Asso 6�9� caeN\ / O C \an9 DN`s• a a � ,Q0 J W (�- o0 Q Z 0 �o OJ M oo O O L N 00 LL [��y V w " w0 z OM 0 C /wT �I J /LLJ (D V X / Pbbott Asso 6�9� caeN\ / O C \an9 DN`s• 19-016 69:Igamr►C•a A3-101 C/) � J W Q M oo O O 00 LL [��y V LU O z >Q 1: /LLJ (D V X Q 00 Lu W �Q M Q rn= LLJ 0 19-016 69:Igamr►C•a A3-101 a 0 N N (`� O N O N r N V ROOF DEMOLITION PLAN 1/16" = T-0" UNIT 116 IIIT7 � R 1111 1 UNIT 115 CORRIDORS: FLOORING: REMOVE CARPET & PADDING. ELECTRICAL: REMOVE EXISTING LIGHT FIXTURES STAIRS: REMOVE CARPET & PADDING, O REMOVE HANDRAILS DOORS: REMOVE EXISTING UNIT ENTRY DOORS I REMOVE EXISTING EXTERIOR BUILDING W ENTRY DOORS UNITS: REFER TO ENLARGED UNIT DEMOLITION PLANS UNIT 119 UNIT 120 UNIT 117 UNIT 11188 F9 — ==...� L UNIT 114 UNIT 113 UNIT 112 T "UNIT 111 T 1� r 7T I 7Ft LEVEL 2 DEMOLITION FLOOR PLAN 1/16" = T-0" 1ri1»_A ALL DRYWALL TO BE REMOVED THROUGHOUT ENTIRE UNIT. REFER TO ENLARGED UNIT DEMOLITION PLANS FOR FURTHER DETAILS AND INFORMATION. NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OFA FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. FLOORING: REMOVE CARPET & PADDING. ELECTRICAL: REMOVE EXISTING LIGHT FIXTURES STAIRS: REMOVE CARPET & PADDING, O REMOVE HANDRAILS DOORS: REMOVE EXISTING UNIT ENTRY DOORS I REMOVE EXISTING EXTERIOR BUILDING W ENTRY DOORS REFER TO ENLARGED UNIT DEMOLITION PLANS UNIT 106 UNIT 107 UNIT 108` UNIT 109 .� � ILL 'r O�- C as � UNIT 105UNIT 104 UNIT 103 UNIT 102 L L LEVEL 1 FLOOR DEMOLITION PLAN Iriill-BIQe➢ :7g9q iEelq►1/_VZelgo1l1►11297:1LA[e]III[07►INI_U61 FLOORING: REMOVE CARPET & PADDING. ELECTRICAL: REMOVE EXISTING LIGHT FIXTURES STAIRS: REMOVE CARPET & PADDING, O REMOVE HANDRAILS DOORS: REMOVE EXISTING UNIT ENTRY DOORS I REMOVE EXISTING EXTERIOR BUILDING W ENTRY DOORS BASEMENT DEMOLITION FLOOR PLAN 1/16" = T-0" UNIT 110 UNIT 101 J�� ' TT w� F UNIT B1 00 UNIT B2 � o a E hK Cp�o ERIC C o F -- Lu U) n O 0 Lu a N O 74 PLAN DATES / pbotl Asso 6�9� caeN\ 0 c \an9 DN`s• �� V Z a O U J O Q O a M� W `Q0( I O W - 00 M O W zcl�c(o 0 Lu Do 0 W 0 N � W (D w M V M O °) o T N. J / pbotl Asso 6�9� caeN\ 0 c \an9 DN`s• �� V Z Q ry O U J O Q O 0� M� W LL z I O W J M O W �Q 0 Lu Do 0 19-016 69:Igilr►C.l A3-103 Lu O U J Q LLJ 0� QDo (D Lu > W �Q co � N 19-016 69:Igilr►C.l A3-103 a N N N (`� O N O N r N V (N) WALL (TYPI)� A2 PROPOSED LEVEL 2 FLOOR PLAN u J 1/8" = T-0" (N) CONC. RAMP TO I FOLLOW ADA STANDARDS=_ (E) CONC. STOOP & BRICK HANDRAIL WALLS TO BE DEMOLISHED & REBUILT NO LESS THAN _ 1/2" BELOW FINISH FLOOR i 1 3-604 (N) MTL. GUARD RAIL (TYP.) I- PATIO I 3 / Aic ATI(CON( STOOP A 2 (N) WINDOW WELL COVERS TO BE PROVIDED ATIO (TYP.) � AT ALL WINDOW WELLS DEEPER THAN 30" PATIO \s/ PATIO PATIO AND WHERE A SIDEWALK IS WITHIN 36" OF MTL. HAND RAIL (TYP.) - - - - - THE EDGE OF THE WINDOW WELL. JI, I III EXTERIOR LIGHT FIXTURE LL LEVEL 1 PATIOS (TYP.)�`A/C A/C A/C '-T 7 \ fT 7 j --T -T // t A/C i !Y !Y 4'-0" 41- 0111 101 UNIT 103 UNIT 105 UNIT 107 Z UNIT 109 0 J_ o J I UNIT TYPE: 3-2.4 UNIT TYPE: 3-2.1 UNIT TYPE: 3-2.1 W UNIT TYPE: 3-1.1 o UNIT TYPE: 3-2.5 M O Q 3 /TYPE A/Z ° O RE: 3 /A3-303 ° 0 RE: 3 /A3-303 O o 0 0Ll RE: 3 /A3-301 0 (� w RE: 3 /A3-308 PATIO ��v//�� U) J Q RE: 2 /A3-307 LLI O a O Q ~ c 0 Q� a W< co Q LO 0) Lu -r 0 C.) 19-016 SHEET NO. 00 2 o O , 5' _ 0^ I ��LINE OF CORRIDOR *--(N) COMMERCIAL CPT. TILES UP FLR. ABOVE �� 3-60 00 ° O DN o ° I ,UNIT 102/ Eo UNIT 104 UNIT 106 UNIT 108 UNIT 110 C UNIT TYPE: 3-2.4 UNIT TYPE: 3-2.1 UNIT TYPE: 3-2.1 0 0 UNIT TYPE: 3-2.1F700-00F]UNIT TYPE: 3-2.5 PATIO �ET2 E 307 RE: 3 /A3-303 RE: 3 /A3-303 RE: 3 /A3-303 a o v RE: 3 /A3-308 0 A/C % A/C PATIO I A/C A/C A/C (N) MTL. GUARD RAIL (TYP.) — — _ _ = PATIO TIO 3-604 PATIO PATIO PATIO A3-402 Cz PROPOSED LEVEL 1 FLOOR PLAN 1/8" = 1'-0" <2 3-402 <2 3-402 m z Z w w Lu O U OF �� a Lu aco wco LU co m 0uio cD�U� W a 00 D comN co m N N O N O N O N W � N H " N O O PLAN DATES a a 00 z0� oJ W OJ N U O0co w " w0 OM O C /wT �I J es Abbott Asso 6�9� caeN\ e��7aipa D``1`�`oc c' J Z J_ J I � W o M O Q O U- co 0 (� w O LU ��v//�� U) J Q O LLI O a O Q ~ c 0 Q� a W< co Q LO 0) Lu -r 0 C.) 19-016 SHEET NO. A3-105 a M N N (`� O N O N r N V CPT. FL SHT. VI FLOOR UNIT 3-1.1 - EXISTING FLOOR PLAN 1/4" = 1'-0" LIVING ROOM BEDROOM SD CLO SD LIN BATH KITCHEN & DINING O T FLOOR/CEILING ASSEMBLY TO FOLLOW RATING AND DETAILS ON SHEET A3-605 UNIT 3-1.1 - REFLECTED CEILING PLAN 1/4" = 1'-0" REMOVE AT UN -SHADED AR -CARPET FLOORING -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES REMOVE AT SHADED AREA: -CABINETS -COUNTERTOPS -APPLIANCES -SHEET VINYL FLOORING -PLUMBING FIXTURES -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES -TUB AND SHOWER SURROL -DASHED ITEMS OVE DRYWALL @ LS IN BATHROOM O WALL =MBLY AT BROOM AT RIDOR WALLS. NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE UNIT 3-1.1 - DEMO FLOOR PLAN REPAIR. 1/4" = T-0" E407 E435 E434_ E401_ E401 E436 UNIT 3-1.1 - PROPOSED FINISH PLAN 1/4" = 1'-0" .]aIIIG1IwKelQG9:ImIa/GBE1-161 424 ❑ UNIT 3-1.1 (LEVEL 1 ONLY) KEY PLAN WALL TYPES LEGEND EXISTING PARTITION TO REMAIN ®DN6911►[H�G1:�111[•]►�CH:3�:7q� [�DIq�] NEW PARTITION ELECTRICAL SYMBOLS EXHAUST FAN SMOKE/ CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN GENERAL UNIT PLAN NOTES: 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 422 REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 NEW VANITY LIGHT FIXTURE 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. 436 REPLACE ALL CEILING FANS IN BEDROOMS 437 ADD EXTERIOR LIGHT FIXTURE AT GROUND FLOOR PATIO WHERE NOTED ON OVERALL PLANS. hK Cp�o ERIC C o Lu U) 0 0 0 Lu a N 0 N 74 PLAN DATES / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z a Q a J_ z W na/ O0 z 0 �D OJ o W N r M 0. co L: Ow o \,/ ~ V M O O) o 11 ,, T M VJ / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z Q a J_ z W a WL r M 0. co L: M o M 0 W U) ;O � Q Lu (D J Q � co 0 Z W W �a co �2 0 19-016 69:Igilr►C•a A3-301 UNIT 3-1.2 - EXISTING FLOOR PLAN 1/4" = 1'-0" FLOOR/CEILING ASSEMBLY TO - FOLLOW RATING AND DETAILS ON SHEET A3-605 UNIT 3-1.2 - REFLECTED CEILING PLAN 1/4" = T-0" REMOVE AT UN-SHAC -CARPET FLOORING -ELECTRICAL SWITCH -ELECTRICAL OUTLET -ELECTRICAL FIXTURE REMOVE AT SHADED -CABINETS -COUNTERTOPS -APPLIANCES -SHEET VINYL FLOORI -PLUMBING FIXTURES -ELECTRICAL SWITCH -ELECTRICAL OUTLET -ELECTRICAL FIXTURE -TUB AND SHOWER SI -DASHED ITEMS UNIT 3-1.2 - DEMO FLOOR PLAN 1/4" = 1'-0" NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. UNIT 3-1.2 - PROPOSED FINISH PLAN 1/4" = 1'-0" .]aIIF-AIwY•]►G9:IgarGvi11.1 7 WALL @ HROOM ASSEMBLY M AT ALLS. ❑ UNIT 3-1.2 (LEVEL 2 ONLY) KEY PLAN WALL TYPES LEGEND I EXISTING PARTITION TO REMAIN ®DN6911Q[el�G1:�111[�]Q�CU:3�:7q� �[�DI q�] NEW PARTITION ELECTRICAL SYMBOLS O EXHAUST FAN SMOKE / CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN GENERAL UNIT PLAN NOTES: I 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 402 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 410 REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS. 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 422 REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 NEW VANITY LIGHT FIXTURE 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. 436 REPLACE ALL CEILING FANS IN BEDROOMS hK Cp�o ERIC C o Lu U) 0 0 0 Lu a N 0 N 74 PLAN DATES / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) V Z a Z J Z Q W r n_/ O0 Z 0 (D o Lu W 0 N M co W O w o F-�---I M O v O T M VJ / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) V Z Z J Z Q W r W � N WI M co L: Q o M D W U) ;O � Q Lu (D J Q Dp p Z W Lu Q co �2 D U (3 19-016 69:Igilr►E.] A3-302 SHT. VIN FLOORI( CPT. FLOORIP UNIT 3-2.1 - EXISTING FLOOR PLAN 1/4" = 1'-0" FLOOR/CEILING ASSEMBLY TO FOLLOW RATING AND DETAILS ON SHEET A3-605 LIGHT PUFF PER SPECS '.. O BATH D LIN CLO O SD BEDROOM1 Op LIVING ROOM CLO BEDROOM1 O SD UNIT 3-2.1 - REFLECTED CEILING PLAN 00 O O SD LIVING ROOM DEMO WALL ASSEMBL" AT BATHROOM AT CORRIDOR WALLS. REMOVE DRYWALL @ WALLS IN BATHROOM WALL F FOLLO DETAIL UNIT 3-2.1 - DEMO FLOOR PLAN 1/4" = 1'-0" REMOVE AT SHADED AREA: -CABINETS -COUNTERTOPS -APPLIANCES -SHEET VINYL FLOORING -PLUMBING FIXTURES -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES -TUB AND SHOWER SURROUND -DASHED ITEMS REMOVE AT UN -SHADED AREA: -CARPET FLOORING -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. UNIT 3-2.1 - FINISH PLAN 1/4" = 1'-0" UNIT 3-2.1 (LEVEL 1 ONLY) KEY PLAN WALL TYPES LEGEND EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS EXHAUST FAN SMOKE/ CARBON MONOXIDE DETECTOR SURFACE MOUNTED LIGHT FIXTURE EMMA10L A[oil]QllgelI[c3:129K411117q UIgIII►Eel yGUI GENERAL UNIT PLAN NOTES: 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 402 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 412 ADD HEADER AT ALL CLOSET DOORS. HEAD HEIGHT @ 6-8". 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND YL G- NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE a REPLACE ALL PLUMBING SHUT-OFF VALVES @ KITCHEN SINK, BATH SINK, TOILET W/ NEW 1/4 TURN VALVES. 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 434 REPLACE ALL LIGHT FIXTURES 435 C O. 436 REPLACE ALL CEILING FANS IN BEDROOMS 603 CORRIDOR WALLS TO BE REPAINTED WITH ACCENT COLOR, PT -7. RE: INTERIOR PAINT SCHEDULE. (TYP.) Q Dp p Z W C^ W 144- �a L co Lo LLJ2 D Uco')�m o O O IG— GBEDROOM1 _CLO. CLO. BEDROOM1BEDROOM 2 LIVING ROOM UNIT 3-2.1 - EXISTING FLOOR PLAN 1/4" = 1'-0" FLOOR/CEILING ASSEMBLY TO FOLLOW RATING AND DETAILS ON SHEET A3-605 LIGHT PUFF PER SPECS '.. O BATH D LIN CLO O SD BEDROOM1 Op LIVING ROOM CLO BEDROOM1 O SD UNIT 3-2.1 - REFLECTED CEILING PLAN 00 O O SD LIVING ROOM DEMO WALL ASSEMBL" AT BATHROOM AT CORRIDOR WALLS. REMOVE DRYWALL @ WALLS IN BATHROOM WALL F FOLLO DETAIL UNIT 3-2.1 - DEMO FLOOR PLAN 1/4" = 1'-0" REMOVE AT SHADED AREA: -CABINETS -COUNTERTOPS -APPLIANCES -SHEET VINYL FLOORING -PLUMBING FIXTURES -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES -TUB AND SHOWER SURROUND -DASHED ITEMS REMOVE AT UN -SHADED AREA: -CARPET FLOORING -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. UNIT 3-2.1 - FINISH PLAN 1/4" = 1'-0" UNIT 3-2.1 (LEVEL 1 ONLY) KEY PLAN WALL TYPES LEGEND EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS EXHAUST FAN SMOKE/ CARBON MONOXIDE DETECTOR SURFACE MOUNTED LIGHT FIXTURE EMMA10L A[oil]QllgelI[c3:129K411117q UIgIII►Eel yGUI GENERAL UNIT PLAN NOTES: 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 402 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 412 ADD HEADER AT ALL CLOSET DOORS. HEAD HEIGHT @ 6-8". 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 430 REPLACE ALL PLUMBING SHUT-OFF VALVES @ KITCHEN SINK, BATH SINK, TOILET W/ NEW 1/4 TURN VALVES. 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. 436 REPLACE ALL CEILING FANS IN BEDROOMS 603 CORRIDOR WALLS TO BE REPAINTED WITH ACCENT COLOR, PT -7. RE: INTERIOR PAINT SCHEDULE. (TYP.) h�pF Cp�o ERIC C o Lu Lu 0 0 0 Lu 0 a N 0 N 74 PLAN DATES / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• V Z a Q a J_ z W r W O o zcl�c(o � W W 0 N N M co WO w o F—�---I OM 0 v O Lo 0 M VJ / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• V Z Q a J_ z W r W � W N M co ~ o M D W U) ;O � Q Lu (� J Q Dp p Z W C^ W 144- �a L co Lo LLJ2 D Uco')�m 19-016 69:Iq011r►[•a A3-303 L CPT. UNIT 3-2.2 - EXISTING FLOOR PLAN 1/4" = 1'-0" FLOOR/CEILING ASSEMBLY TO FOLLOW RATING AND DETAILS ON SHEET A3-605 LIGHT PUFF PER SPECS UNIT 3-2.2 - REFLECTED CEILING PLAN 1/411 = 1'-0" DEMO WALL ASSEMB' 11 AT BATHROOM AT CORRIDOR WALLS. REMOVE DRYWALL Ca WALLS IN BATHROOM UNIT 3-2.2 - DEMO FLOOR PLAN 1/4" = 1'-0" NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. UNIT 3-2.2 - FINISH PLAN 1/4" = 1'-0" AT SHADED AREA: -S RTOPS ICES IINYL FLOORING JG FIXTURES ICAL SWITCHES ICAL OUTLETS ICAL FIXTURES )SHOWER SURROUND ITEMS AT UN -SHADED AREA: FLOORING ICAL SWITCHES ICAL OUTLETS ICAL FIXTURES ❑ UNIT 3-2.2 (LEVEL 2 ONLY) KEY PLAN WALL TYPES LEGEND I EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS D EXHAUST FAN SMOKE / CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN I GENERAL UNIT PLAN NOTES: I 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 412 ADD HEADER AT ALL CLOSET DOORS. HEAD HEIGHT @ 6-8". 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 417 NEW BLACKTOP -FREEZER REFRIDGERATOR 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. hK Cp�o ERIC C o Lu U) 0 0 0 Lu a N 0 N 74 PLAN DATES / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z a Q a J_ z W r na/ O0 z�c(D WL W 0 N N M 0. co L: Ow o -- 0 M v O T M VJ / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z Q a J_ z W r W N WL N M 0. co L: M o M D W U) ;O E Q Lu (D J Q H Dp p Z W Lu a co Qrn = (D 0 U��m 19-016 69:Igamr►C•a A3-304 UNIT 3-2.3 - EXISTING FLOOR PLAN 1/4" = 1'-0" UNIT 3-2.3 - REFLECTED CEILING PLAN irzl I ISl➢ J LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) III RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 404 A/C BEDROOM 1 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 LIVING ROOM 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. UNIT 3-2.3 - DEMO FLOOR PLAN 1/4" = 1'-0" DRYWALL @ JBATHROOM AT UN -SHADED AREA: FLOORING ICAL SWITCHES ICAL OUTLETS ICAL FIXTURES AT SHADED AREA: FS =RTOPS ICES IINYL FLOORING JG FIXTURES ICAL SWITCHES ICAL OUTLETS ICAL FIXTURES D SHOWER SURROUND ITEMS UNIT 3-2.3 - PROPOSED FINISH PLAN ❑ UNIT 3-2.3 (LEVEL 2 ONLY) KEY PLAN WALL TYPES LEGEND I EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS 0 EXHAUST FAN SMOKE / CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN I GENERAL UNIT PLAN NOTES: I 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 422 REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 428 REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING TUB WHERE REQ'D. 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 NEW VANITY LIGHT FIXTURE 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. 436 REPLACE ALL CEILING FANS IN BEDROOMS hK Cp�o ERIC C o Lu U) 0 0 0 Lu a N 0 N 74 PLAN DATES / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z a Q a J_ z W r na/ O0 z 0 (D OJ o Lu N W N M 0. co L: Ow o -- 0 M v O T M VJ / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z Q a J_ z W r CIOW � WI N M 0. co L: M o M D W U) ;O � Q Lu (D J Q H Dp p Z W ui Q co LJJ 2 (D� D Um�m 19-016 69:Igilr►Ce] A3-305 a 0 M M 0 N O N r N V a 68 1/2" FUR 2x6 WALL OUT AT EXTERIOR FOR ADDITIONAL PLUMBING & INSULATION REFER TO ROLL -IN SHOWER DETAILS ON SHEET A3-606 VANITY WITH REMOVABLE CABINET & PIPE PROTECTION AT SINK. PAINT WALL BEHIND CABINET & EXTEND FLOORING BENEATH CABINET. NEW FLOORING MATERIAL TO BE SMALL -FORMAT TILE, SPEC, TBD BY ARCHITECT. SLOPE TILE TOWARDS FLOOR DRAIN & SHOWER THRESHOLD. ADD BLOCKING FOR GRAB BARS THESE LOCATIONS. REFER TO DETAILS ON SHEET A3-606. UNIT 3-2.4 TYPE A - ENLARGED BATHROOM 1/211 = 1'-0" BEDROOM 1 CLO. Sp BEDROOM 2 GENERAL UNIT PLAN NOTES: 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT 3-2.4 TYPE A - FINISH PLAN 1/411 = 1'-0" 7' - 8" 1 12'- 1 3/4" 5 I (N) BLOCKING TO BE 3-307 I INSTALLED D LIVING ROOM BEDROOM 1 i f<6 ,BATHLIVING ROOM FLOOR/CEILING ASSEMBLY TO 3-80 4> 11 BATH FOLLOW RATING AND DETAILS (E) RADIANT BASE BOARD a ON SHEET A3-605 HEATING ELEMENT TO BE RELOCATED TO NEW WALL 22 21 (N) BLOCKING TO BE INSTALLED N CLO. SD J ALIGN WALLS 22 KITCHEN & z 1 CLO. DINING CLO. ALIGN WALLS A3-80 2> - � I of KITCHEN & DININGV r r�� V BEDROOM 2 \I i 18" � _ MIN. L L O L o $ o NEW WALLS TO FOLLOW RATING AND DETAILS FOR CORRIDOR WALL 7 1/2" ASSEMBLY. RE: A3-605 12" MIN. UNIT 3-2.4 - TYPE A - REFLECTED CEILING PLAN 1/4" = 1'-0" UNIT 3-2.4 TYPE A - PROPOSED FLOOR PLAN 1/4" = 1'-0" 11m ❑ UNIT 3-2.4 TYPE A (LEVEL 1 ONLY) KEY PLAN WALL TYPES LEGEND EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS O EXHAUST FAN SMOKE / CARBON MONOXIDE DETECTOR SID SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 410 REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS. 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 422 REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 NEW GARBAGE DISPOSAL 428 REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING TUB WHERE REQ'D. 431 NEW CHROME BATH ACCESSORIES 433 NEW VANITY LIGHT FIXTURE 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. 436 REPLACE ALL CEILING FANS IN BEDROOMS 439 SIDE-BY-SIDE REFRIDGERATOR/FREEZER W/ WATER & ICE DISPENSER @ ALL TYPE 'A' UNITS. 440 30" MIN. CLEAR WORKSPACE REQ'D IN TYPE W UNITS. PROVIDE REMOVABLE CABINET FACE & EXTEND FINISH FLOOR TO FACE OF WALL. PAINT WALL BEHIND CABINET. 441 PROVIDE REMOVABLE CABINET FACE @ SINK CABINET & EXTEND FINISH FLOOR TO FACE OF WALL BEYOND. PAINT WALL BEHIND. 443 MICROWAVE TO BE MOUNTED UNDER 34" COUNTER TOP @ ALL TYPE 'A' UNITS. 444 ADA COMPLIANT DISHWASHER TO FIT UNDER 34" COUNTER AT ALL TYPE 'A' UNITS. 446 RECESS GARBAGE DISPOSAL AIR SWITCH INTO COUNTERTOP WITHIN ADA REACH RANGES @ ALL TYPE 'A' UNITS. 449 PROVIDE REINFORCEMENT FOR WALL MOUNTED GRAB BARS. W= w 2 Lu 2J U O F 0 a2 Lu Lu �5 ¢ j co 00 mm 0 0 N PLAN DATES a a 00 z12�c(o W 0 N • r� U o O o O o W O w O o M — x LoO � cD s pbotl gsso a v�9� ca�w� 0 eG�� 2\c a�p9 p� J c n) (D V C/) Z = a J_ Q W a � N W M 0. co M L: o M D W U) ; UNIT 3-2.5 - EXISTING FLOOR PLAN 1/4" = 1'-0" 0 KITCHEN & DINING 7:S FLOOR/CEILING ASSEMBLY TO FOLLOW RATING AND DETAILS ON SHEET A3-605 LIVING ROOM CLO B ROOM 1 O� CLO ❑ BATH 0 O" CLO �;oou UNIT 3-2.5 - REFLECTED CEILING PLAN 1/411 = 1'-0" REMOVE AT SHADED -CABINETS -COUNTERTOPS -APPLIANCES -SHEET VINYL FLOOR -PLUMBING FIXTURES -ELECTRICAL SWITCH -ELECTRICAL OUTLET -ELECTRICAL FIXTURE -TUB AND SHOWER SI -DASHED ITEMS REMOVE AT UN-SHAE -CARPET FLOORING -ELECTRICAL SWITCH -ELECTRICAL OUTLET -ELECTRICAL FIXTURE REMOVE DRYWALL Ca WALLS IN BATHROOM UNIT 3-2.5 - DEMO FLOOR PLAN 1/4" = 1'-0" FILING OR ITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OFA FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. UNIT 3-2.5 - PROPOSED FINISH PLAN 1/4" = 1'-0" ❑ UNIT 3-2.5 KEY PLAN WALL TYPES LEGEND I DyN6911►[el�G1:�111[•]►�C•7:7q� G11Q EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS O EXHAUST FAN SMOKE / CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN I GENERAL UNIT PLAN NOTES: I 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 402 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 404 REPAINT ALL WINDOW SILLS 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 422 REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 424 NEW PORCELAIN TOILET, WHITE 428 REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING TUB WHERE REQ'D. 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 NEW VANITY LIGHT FIXTURE 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. 436 REPLACE ALL CEILING FANS IN BEDROOMS hK Cp�o ERIC C o Lu U) 0 0 0 Lu a N 0 N 74 PLAN DATES / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z a Q a J_ z C7 r n_/ O0 z�c(D WL W 0 N N M 0. co W O w o F-�---I M O v O T M 0 LLJ / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• cy) (D Z Q a J_ z C7 r LoW WL N M 0. co L: o M 0 LLJ O W (D U) ' Q Lu (D J Q Dp 0 Z W Lu a co � LLJ 2 0 Urn�m 19-016 69:Igamr►C•a A3-308 UNIT 3-2.6 - EXISTING FLOOR PLAN 1/4" = 1'-0" UNIT 3-2.6 - REFLECTED CEILING PLAN 1/4" = 1'-0" REMOVE DRYWALL @ WALLS IN BATHROOM REMOVE AT UN -SHADED AF -CARPET FLOORING -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES REMOVE AT SHADED AREA: -CABINETS -COUNTERTOPS -APPLIANCES -SHEET VINYL FLOORING -PLUMBING FIXTURES -ELECTRICAL SWITCHES -ELECTRICAL OUTLETS -ELECTRICAL FIXTURES -TUB AND SHOWER SURROI -DASHED ITEMS UNIT 3-2.6 - DEMO FLOOR PLAN 1/4" = 1'-0" J NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. 429 lf==F �427] LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 431 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 410 REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS. 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS LIVING ROOM BEDROOM 1 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 403 :B:P TH REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 fT / 414 NEW PORCELAIN TOILET, WHITE 425 426 EA: 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 425 x 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 >f7 432 4 3-80 DBEDROOM 1 435 CTO CTO Lu a =433 3 �2 407 0 G') 410 I =402 BEDROOM 2 JND 435= 401 —CLO WIC/ - 414 I OO �— 415 416 O O =420 W A3-80 2 =422 421 1 BEDROOM 2 UNIT 3-2.6 - DEMO FLOOR PLAN 1/4" = 1'-0" J NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE REPAIR. 429 lf==F �427] UNIT 3-2.6 - PROPOSED FINISH PLAN 1/4" = 1'-0" ❑ UNIT 3-2.6 (BASEMENT ONLY) KEY PLAN I WALL TYPES LEGEND I EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS D EXHAUST FAN SMOKE/ CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN I GENERAL UNIT PLAN NOTES: I 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 431 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 410 REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS. 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 403 :B:P TH REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 NEW GARBAGE DISPOSAL 414 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 415 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 425 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 434 432 4 3-80 DBEDROOM 1 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. Lu a =433 3 �2 407 0 G') 410 I =402 435= 401 —CLO 405= 414 I 415 416 =420 W A3-80 2 =422 421 1 BEDROOM 2 a?'I 418 � o ° 419 000 UNIT 3-2.6 - PROPOSED FINISH PLAN 1/4" = 1'-0" ❑ UNIT 3-2.6 (BASEMENT ONLY) KEY PLAN I WALL TYPES LEGEND I EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NEW PARTITION ELECTRICAL SYMBOLS D EXHAUST FAN SMOKE/ CARBON MONOXIDE DETECTOR SD SURFACE MOUNTED LIGHT FIXTURE Q WALL MOUNTED LIGHT FIXTURE CEILING FAN I GENERAL UNIT PLAN NOTES: I 1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES. 3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY. FIELD VERIFY LOCATIONS AND FIXTURE TYPES. 4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES. 5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT. 6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE MOUNTED LIGHT FIXTURE U.N.O. UNIT INTERIORS - SCHEDULE NO. DESCRIPTION 401 LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD 1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT. WAS DEMOLISHED (TYP.) 402 CARPET FLOORING W/ RUBBER TRANSITION STRIPS. 403 RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH) 405 REPAINT ALL CLOSET SHELVES 407 PAINT WALLS AND CEILING 410 REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS. 414 PLASTIC LAMINATED COUNTER TOPS 415 NEW BASE CABINETS W/ CABINET PULLS 416 NEW UPPER CABINETS W/ CABINET PULLS 418 NEW BLACK ELECTRIC RANGE 419 NEW BLACK OVER -RANGE MICROWAVE 420 NEW BLACK DISHWASHER 421 NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE 422 REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET 423 NEW GARBAGE DISPOSAL 424 NEW PORCELAIN TOILET, WHITE 425 NEW DROP-IN PORCELAIN SINK BOWL, WHITE 426 NEW CHROME SINK FAUCET 427 NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND 429 NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE 431 NEW CHROME BATH ACCESSORIES 432 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 433 NEW VANITY LIGHT FIXTURE 434 REPLACE ALL LIGHT FIXTURES 435 REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING WIRING TO REMAIN U.N.O. hK Cp�o ERIC C o Lu U) 0 0 0 L a 0 74 PLAN DATES / pbotl Asso 6�9� caeN\ 0 c \an9 DN`s• r� V Z a Q a J_ a z W W 00 z a c(D � WL U L 0 N • �--� 0. o °co M W O w o F-�---I OM v O T D 0 C) / pbotl Asso 6�9� caeN\ 0 c \an9 DN`s• r� V Z Q a J_ z W W � WL N M 0. M ~ Q o D 0 C) 0 W /1 � Q W (D Q J Q H Dp p Z W Lu a co �2 D 0 G') 19-016 69:Igilr►C•a A3-309 SOUTH - EXISTING J 1/8" = 1'-0" ROOF 116' - 9 LEVEL 2 108'- " LEVEL 100' - 0" BASEMENT 92' - 0" BEAST - EXISTING v % 1/8" = 1'-0" BASEMEN 92' - 0" 1 9.. 2 9 NORTH - EXISTING 1/8" = 1'-0" �z -u Y WEST - EXISTING 1/8" = 1'-0" EXTERIOR MATERIAL SCHEDULE NO. DESCRIPTION 211 EXISTING DOORS (AND WINDOWS, WHERE OCCURS) AT BUILDING ENTRIES TO BE DEMOLISHED (TYP.) 214 EXISTING BRICK WALLS AT BUILDING ENTRY STOOPS TO BE REPAIRED, V.I.F. IF NECESSARY (TYP.) 217 ALL EXTERIOR UNIT STOOPS & PATIOS TO BE DEMOLISHED (TYP.) 219 EXISTING BALCONY GUARDRAILS TO BE DEMOLISHED (TYP.) 222 EXISTING LIGHT FIXTURE AT BALCONIES TO BE REPLACED (TYP.) RE: FINISH SCHEDULE 224 EXISTING BUILDING ADDRESS NUMBERS TO BE DEMOLISHED (TYP.) 228 EXISTING METAL GUARDRAIL AT EXTERIOR BASEMENT STAIRS TO BE DEMOLISHED. F -- Lu U) Z p O O � 0 aW UQ C)o Lu a_ o� N 0 N W 0 PLAN DATES a a 00 z�c(o W 0 N • 0co WO w Oo00 M - LoO 11 ,, x � cD T V J es pbotl Asso 6�9� caeN\ / e��7aipa D``1`�`oc r� V Z c/) z 0 J Q Lu J W W 0 0. M CIOLu � O w LU 0 Z Qw Q �p X w co W< co cD Qrn Lu = 0 C) 19-016 SHEET NO. A3-401 NEW LIGHT NEW ALUM. FRONT ENTI 1►1��1�11d1�: LEVEL 1 100' - 0" ENLARGED EAST BUILDING ENTRY 1/411 = 1'-0" 6'-0"VIF EXISTING R.O. ROOF 116' - 9" NEW METAL ROOFING NEW TRIM BOARD, PTD. w/ ACCENT COLOR ALUMINUM STOREFRONT ENTRY 1181.9 Lel NEW BUILDING ENTRY LIGHTING NEW EXTERIOR ARYLIC BUILDING SIGNAGE ADA PUSH -ASSIST \ DOOR OPEN BUTTON NEW MTL. WIRE MESH HANDRAIL LEVEL 1 1001-0 " ENLARGED NORTH BUILDING ENTRY 1/4" = 1'-0" 5 NORTH - PROPOSED ELEVATION 1/8" = 1'-0" IrPM&I E223] z�i_2_1 LEVEL loo. -O.- 210 - 209 00'-0"210- 209 1 SOUTH - PROPOSED ELEVATION 2 % 1/8" = 1'-0" ROOF 116' - 9" LEVEL 2 108' _9 9" LEVEL0 " 1 100' - WEST -PROPOSED 4 % 1/8" = 1'-0" ROOF 116' - 9" EVEL 2 108' - 9" EVEL1 100' - 0" GENERAL EXTERIOR RENOVATION NOTES: 1. EXISTING CONDITIONS OF EXTERIOR MAY VARY - IF EXTERIOR CONDITIONS VARY FROM WHAT IS SHOWN IN ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO EXTERIOR PAINT SCHEDULE FOR SPECIFIC PAINT TYPES AND LOCATIONS. 3. REPAIR OR REPLACE ANY DAMAGED MATERIALS THAT HAVE BEEN NOTED TO REMAIN ON PLANS. V.I.F. IF NECESSARY. EXTERIOR PAINT SCHEDULE NO. MANUFACTURER MODEL COLOR COMMENTS PT -1 n SW 7045 'INTELLECT SIDING PAINT COLOR BERRIDGE 'DEEP DECK' VERTICAL METAL PANEL, "DARK BRONZE" COLOR, TO BE INSTALLED ON ALL MANSARDS. UAL GREY' INSTALL OVER #30 FELT OVER THE TOP OF EXISTING PT -2 SHERWIN WILLIAMS NORTH - PROPOSED ELEVATION 1/8" = 1'-0" IrPM&I E223] z�i_2_1 LEVEL loo. -O.- 210 - 209 00'-0"210- 209 1 SOUTH - PROPOSED ELEVATION 2 % 1/8" = 1'-0" ROOF 116' - 9" LEVEL 2 108' _9 9" LEVEL0 " 1 100' - WEST -PROPOSED 4 % 1/8" = 1'-0" ROOF 116' - 9" EVEL 2 108' - 9" EVEL1 100' - 0" GENERAL EXTERIOR RENOVATION NOTES: 1. EXISTING CONDITIONS OF EXTERIOR MAY VARY - IF EXTERIOR CONDITIONS VARY FROM WHAT IS SHOWN IN ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE. 2. REFER TO EXTERIOR PAINT SCHEDULE FOR SPECIFIC PAINT TYPES AND LOCATIONS. 3. REPAIR OR REPLACE ANY DAMAGED MATERIALS THAT HAVE BEEN NOTED TO REMAIN ON PLANS. V.I.F. IF NECESSARY. EXTERIOR PAINT SCHEDULE NO. MANUFACTURER MODEL COLOR COMMENTS PT -1 SHERWIN WILLIAMS SW 7045 'INTELLECT SIDING PAINT COLOR BERRIDGE 'DEEP DECK' VERTICAL METAL PANEL, "DARK BRONZE" COLOR, TO BE INSTALLED ON ALL MANSARDS. UAL GREY' INSTALL OVER #30 FELT OVER THE TOP OF EXISTING PT -2 SHERWIN WILLIAMS SW 7645 'THUNDER EXTERIOR TRIM COLOR, TO BE INSTALLED AS FASCIA PANEL AT TOP OF �� ��//J V W MANSARDS. INSTALL OVER EXISTING CONDITIONS GREY' (TYP.) PT -3 SHERWIN WILLIAMS SW 7645 'THUNDER GUTTERS & EXISTING BRICKVENEER TO REMAIN (TYP.) 210 EXISTING BRICK ROWLOCK SILL TO REMAIN (TYP.) GREY' DOWNSPOUTS PT -4 SHERWIN WILLIAMS SW 6424 'TANSY SOFFITS & MANSARD WINDOW SCHEDULE. 213 EXISTING ENTRY STOOPS TO BE DEMOLISHED & GREEN' COLOR PT -5 SHERWIN WILLIAMS SW 6258 'TRICORN EXTERIOR METALS RAIL AT BOTH SIDES OF STAIRS & PAINTED, PT -5. RE: EXTERIOR PAINT SCHEDULE. (TYP.) BLACK' NEW METAL GUARDRAIL TO BE INSTALLED AT ALL EXTERIOR MATERIAL SCHEDULE NO. DESCRIPTION 201 NEW PRE -FINISHED GUTTERS & DOWN SPOUTS, (TYP.) a PT -3. RE: EXTERIOR PAINT SCHEDULE. 202 BERRIDGE 'DEEP DECK' VERTICAL METAL PANEL, "DARK BRONZE" COLOR, TO BE INSTALLED ON ALL MANSARDS. a INSTALL OVER #30 FELT OVER THE TOP OF EXISTING `Q0( ASPHALT SHINGLES (TYP.) 203 BERRIDGE FASCIA METAL PANEL, "DARK BRONZE" - COLOR, TO BE INSTALLED AS FASCIA PANEL AT TOP OF �� ��//J V W MANSARDS. INSTALL OVER EXISTING CONDITIONS z�c(o (TYP.) 208 EXISTING VERTICAL SIDING TO BE REPAINTED, PT -1. • �--� RE: EXTERIOR PAINT SCHEDULE. 209 EXISTING BRICKVENEER TO REMAIN (TYP.) 210 EXISTING BRICK ROWLOCK SILL TO REMAIN (TYP.) 212 NEW ALUM. STOREFRONT SYSTEM TO BE INSTALLED M O °) o WITHIN EXISTING ROUGH OPENING OF ENTRY DOOR (AND WINDOW, WHERE OCCURS). RE: ARCH DOOR & WINDOW SCHEDULE. 213 EXISTING ENTRY STOOPS TO BE DEMOLISHED & REBUILT (TYP.) 218 NEW CONCRETE STOOPS & PATIOS TO BE INSTALLED AT ALL 1 ST FLOOR UNITS. PROVIDE +36" MTL. HAND RAIL AT BOTH SIDES OF STAIRS & PAINTED, PT -5. RE: EXTERIOR PAINT SCHEDULE. (TYP.) 220 NEW METAL GUARDRAIL TO BE INSTALLED AT ALL SECOND FLOOR BALCONIES & PAINTED, PT -5. RE: EXTERIOR PAINT SCHEDULE. 221 ADDITIONAL EXTERIOR PATIO LIGHT TO BE INSTALLED AT ALL EXTERIOR UNIT PATIO DOORS (TYP.) 223 NEW WALL MTD. EXTERIOR LIGHT FIXTURES TO BE INSTALLED AT ALL BUILDING ENTRIES (TYP.) 225 NEW TWO -TONED EXTERIOR ACRYLIC BUILDING SIGNAGE. RE: ENLARGED EXTERIOR ENTRY FOR DETAILS 257 NEW WHITE VINYL CASEMENT WINDOW AT TYPE 'A' UNITS (TYP.) 258 NEW CONCRETE PATIO & RAILING AT TYPE 'A' UNITS. RE: A3-604 FOR DETAILS. V V Y V V V A 12 3/4" 6 1/2" CL6 1/4" 1" BREVIA FONT, COLOR -1 31/2"HELVETICA 0 FONT, COLOR -2 1" BREVIA FONT, COLOR -1 EXTERIOR BUILDING SIGNAGE 1 1/2" = 1'-0" �yyw SO W= Lu U) 0 O 0 Lu a PLAN DATES 0 Q > a LU W Q LuJ a 0 `Q0( W Q co M X - 00 �� ��//J V W � �Q z�c(o L co U W 0 N • �--� 0 o °co WE_qO w 0 V x M O °) o / pbotl Asso 6�9� caeN\ i 0 c \an9 DN`s• V C7 Z 0 Q > J LU W Q LuJ I 0 Lu W Q co M X Q 0 W co 0 19-016 69:Igilr►C•] A3-402 W o LU ��v//�� VJ Q O Lu CD a 0 Q ~ c 0 � a �� ��//J V W � �Q L co 0 19-016 69:Igilr►C•] A3-402 2x4 STL. ANGLED TOP RAIL 1 1/2" 0 STD STL. PIPE HANDRAIL. WELD ALL JOINTS AND GRIND SMOOTH (PAINT) STL. WIRE MESH WITH 1x2 OPENINGS 2x2 STL. TUBE BALUSTERS WITH 1 1/2 x 1 1/2 STL. ANGLE WELDED (w/ WIRE MESH PANELS.) ALL JOINTS TO BE GRIND SMOOTH (PAINT) I x D Z I T.O. SLAB ELEV. VARIES CONCRETE SLAB RE: STRUCTURAL PLANS 1 1/2',, 2", T1 1/2" 01 nil nnInI RAMP AND GUARDRAIL SECTION DETAIL 1" = 1'-0" 5'-4" 1 1/2 2", T1 1/2" RAMP GUARDRAIL ELEVATION DETAIL 1" = 1'-0" 3 5' - 4" 001 STL. ANGLED TOP RAIL ?" 0 STD STL. PIPE HANDRAIL WELD JOINTS & GRIND SMOOTH (PAINT) WIRE MESH WITH 1x2 OPENINGS STL. TUBE BALUSTERS WITH 1 1/2x1 3TL. ANGLE WELDED (w/ WIRE 3H PANELS.) ALL JOINTS TO BE VD SMOOTH (PAINT) T.O. SLAB ELEV. VARIES JCRETE WALL RE: UCTURAL PLANS 1 1/2 2 1 1/2" I III III 'III- ii1—' 1 I -r- I 1 1-1 1 1 1 1/2" 0 STD STL. PIPE HAN ALL JOINTS & GRIND SMO( of nil 7i - nil ENLARGED RAMP PLAN 1/2" = 1'-0" F -- Lu J) 0 O 0 Lu a PLAN DATES a (D a 00 J_ zcl�((o OJ a U L N q o °co W O w o M O O Lu W C /wT �I J o O. co Oo Z co J_ Q C)0 0� U) ; y SIDE STAIR RAILING DETAIL 1" = 1'-0" ?" 0 STD STEEL HANDRAIL WIRE MESH WITH OPENINGS ?x STL. TUBE LISTER ?" x 1 1/2" STL. ANGLE USTERS (W/ WIRE 3H PANELS) WELDED XISTING STL. .UMNS. ALL JOINTS TO GRIND SMOOTH (PAINT) 'E: FIELD PAINT ALL EL RAILINGS & POSTS LEVI ELEVATION V LEVI ELEVATION V.I.F STAIR RAILING DETAIL 1" = 1'-0" 2" 0 STD STEEL PIPE HANDRAIL 3'-0" ABOVE TREADS WIRE MESH WITH 1x2 OPENINGS 2x STL. TUBE BALUSTER 2" x 1 1/2" STL. ANGLE BALUSTERS WIRE MESH PANELS) WELDED TO STING STL. COLUMNS. ALL JOINTS BE GRIND SMOOTH (PAINT) fE: FIELD PAINT ALL EL RAILINGS & POSTS hK Cp�o ERIC C o 74 J) p OF U FF LU co W H 0 Z) Q U M a 0z co N N � O N N O � N � Ln PLAN DATES / Pbbott Asso 6�9� caeN\ 0 c \an9 DN`s• co V Z W VJ 19-016 69:IqM11r►C6] A3-602 a a ,Qo 00 z 0 (D OJ o Lu N W w "wo O � M v O C /wT �I J / Pbbott Asso 6�9� caeN\ 0 c \an9 DN`s• co V Z W VJ 19-016 69:IqM11r►C6] A3-602 0 PATIO FLUSH AT DOOR FINISH FLOOR LEVEL 1 100' - 0" d - CONC. PATIO8- w SLOPE AT 1/4" PER FOOT AWAY FROM BUILDING— ;_, e -CONC. PATIO W/ TURNDOWN EDGE RE:1/S3 101 SIMILAR CONC. HAUNCH TO CONNECT TO EXISTING BUILDING FOUNDATI RE:3/S3-100SIMILAFZ i it l li�i i it 1 1 TYPE W PATIO SECTION 1" = 1'-0" J_ U Lu m M w 691�G1Q[e3��C•]���G\Iq 7 GAUGE (3/16") STL. WIRE MESH WITH 1x2 OPENINGS 3X3 STL. TUBE POST ATTACH TO CONC. PATIO W/ STL. PLATE 2x2 STL. ANGLE FRAME w/ 1x2 WIRE MESH WELDED TO 3x3 STL. BALUSTERS. ALL JOINTS TO BE GRIND SMOOTH (PAINT) NOTE: FIELD PAINT ALL STEEL RAILINGS & POSTS NOTE: FIELD PAINT ALL STEEL RAILINGS & POSTS 3X3 STL. TUBE POST ATTACH TO CONC. PATIO W/ STL. PLATE 2x2 STL. ANGLE FRAME w/ 1x2 WIRE MESH WELDED TO 3x3 STL. TUBE POST. ALL JOINTS TO BE GRIND SMOOTH (PAINT) 7 GAUGE (3/16") STL. WIRE MESH WITH 1x2 OPENINGS ALL RAILINGS AT TYPE W PATIOS TO BE +42" ABOVE FINISH PATIO SURFACE (N) CONC. E 41 - 011 4'-0" 64 a 8 J a Q ,Q0 M O U p mt zcl�c(o o 0 F O o 0 co W vil LLQ 0 / �/1 W V M O � CD 1 , T L co Q w m Lu A d-, p - � J_ U Lu m M w 691�G1Q[e3��C•]���G\Iq 7 GAUGE (3/16") STL. WIRE MESH WITH 1x2 OPENINGS 3X3 STL. TUBE POST ATTACH TO CONC. PATIO W/ STL. PLATE 2x2 STL. ANGLE FRAME w/ 1x2 WIRE MESH WELDED TO 3x3 STL. BALUSTERS. ALL JOINTS TO BE GRIND SMOOTH (PAINT) NOTE: FIELD PAINT ALL STEEL RAILINGS & POSTS NOTE: FIELD PAINT ALL STEEL RAILINGS & POSTS 3X3 STL. TUBE POST ATTACH TO CONC. PATIO W/ STL. PLATE 2x2 STL. ANGLE FRAME w/ 1x2 WIRE MESH WELDED TO 3x3 STL. TUBE POST. ALL JOINTS TO BE GRIND SMOOTH (PAINT) 7 GAUGE (3/16") STL. WIRE MESH WITH 1x2 OPENINGS ALL RAILINGS AT TYPE W PATIOS TO BE +42" ABOVE FINISH PATIO SURFACE (N) CONC. E 41 - 011 4'-0" 64 PATIO FLUSH J AT DOOR THRESHOLD EXISTING WALL TO REMAIN EXISTING DOOR TO REMAIN LIVING ROOM UNIT TYPE 3-2.4 - TYPE A PATIO DETAIL 1" = 1'-0" I hK Cp�o ERIC C o 74 Lu a J a Q ,Q0 M O U p mt zcl�c(o o U F O o 0 co W d LLQ 0 / �/1 W V M O � CD 1 , T L co Q w m Lu A d-, p - � ¢ W M 0 o o ¢ co N a e. 4° - .dtfi- n. 14 = a; -. ° -d ` 'PATIO d - a d:._ o 44-a:a Lu.e�. d' e d. d d O a , d u) d,e .d d - n d d ` 8 PATIO FLUSH J AT DOOR THRESHOLD EXISTING WALL TO REMAIN EXISTING DOOR TO REMAIN LIVING ROOM UNIT TYPE 3-2.4 - TYPE A PATIO DETAIL 1" = 1'-0" I hK Cp�o ERIC C o 74 Lu a J a Q ,Q0 M O U p 0 zcl�c(o o U F O o 0 co W (j W 0 LLQ 0 / �/1 W V M O � CD 1 , T L co Q w m Lu p � ¢ W M 0 o o ¢ co N PLAN DATES / Pbbott Asso 6�9� caeN\ 0 C \ana 500 W a M a Q ,Q0 M O 00 0 zcl�c(o U W 0 N • 1--� o 0 co W (j W 0 LLQ 0 / �/1 W V M O � CD 1 , T L co Q rn= LU cD 0 / Pbbott Asso 6�9� caeN\ 0 C \ana 500 W M Q M O 00 0 ;J I..L CD 0 � LLQ 0 / �/1 W � �Q L co Q rn= LU cD 0 19-016 A3-604 SECTION AT TYPICAL ROLL -IN SHOWER 1 112" = 1'-U" ROD TO BE D AT ALL SHOWERS WINATION BAR TRIP AT ALL EXPOSED ES ON WALLS (TYP.) SURROUND TO BE TILE AT LOCATIONS W/ WINDOW. IF OW, SHOWER SURROUND TO 1ANUFACTURED FIBER GLASS. ADDITIONAL LAYER OF 'X' GYP. BIRD. AT ALL (ALL ASSEMBLIES. RE: =D PLANS FOR DETAILS TIOUS BACKER O SIT ON FLANGE /ER SURROUND (TYP.) UFACTURED SHOWER PAN. RGED PLANS FOR SIZE DRAIN, RE: PLUMBING ATION & SIZE .00R MATERIAL TO BE SLOPED - OF SHOWER PAN AT 1/4" PER FOOT. 5/8" TILE ON 1/4" MORTAR BED ON 1/8" DECOUPLING MEMBRANE 42" MIN 6" 36" MIN MINIMUM REINFORCED AREA EVEN LARGER REINFORCING r/// PREFERRED FOR L� GREATER EASE WHEN �1- ADDITIONAL 2" MIN. EACH SIDE AND BOTTOM RECOMMENDED TO MOUNT 24" LONG STANDARD GRAB BAR MINIMUM REINFORCING BEHIND TOILETS LOCATED BESIDE A WALL IF THIS DIMENSION IS LESS THAN 12", THEN THE 42" MIN. MUST BE CORRESPONDINGLY LONGER TO ACCOMMODATE A 24" BAR, THE REINFORCED AREA SHOULD BE 28" TO 32" LONG TO PROVIDE FULL SUPPORT FOR THE MOUNTING PLATES MINIMUM REINFORCED AREA 2"- 4" ADDITIONAL REINFOREING AT SIDES AND BOTTOM RECOMMENDER W > 0- 0 - LU 0 Lu Lu O x m 54" MIN 12" 42" MIN MAX 3911-4111 z ro MINIMUM REINFORCING ADJACENT TO TOILETS LOCATED BESIDE A WALL MIN. REINFORCING AT TOILETS 1/2" GENERAL ACCESSIBLE SHOWER NOTES: 1. ADD WATER DIVERTER CONTROL FOR USE BETWEEN BOTH FIXED AND HAND-HELD SHOWER HEADS. 2. ALL SHOWER CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRAPSING, PINCHING, OR TWISTING OF THE WRIST. 3. SHOWER PAN THRESHOLDS CANNOT EXCEED 1/2" TRANSITION AT FINISH FLOOR MATERIAL. 4. PROVIDE SHOWER CURTAIN ROD AT ALL ROLL -IN SHOWERS. SHOWER PAN WIDTH VARIES RE: UNIT PLANS HAND-HELD SHOWER & CONTROLS 16" - 27" FROM EDGE OF SEAT WALL 2 1/2" 15" - 16" MAX. SHOWER SEAT 4 ml�g STANDARD ROLL IN SHOWER PLAN STANDARD ROLL -IN ACCESSIBLE SHOWER REMOVABLE BATHROOM CABINET ISOMETRIC TROL WALL o 0 F W F - - -- -1 U z 0 V)W � ¢ > m z O STANDARD ROLL IN SHOWER PLAN STANDARD ROLL -IN ACCESSIBLE SHOWER REMOVABLE BATHROOM CABINET ISOMETRIC o 0 F W F - - -- -1 U z PLAN DATES � ¢ > m z O I Lu W = Lu W = O o Z O ¢ J LL F ¢ z a Lux - Z m w cC w 3:z = U w x W W W O w F z w U L J z 0 (D OJ 60" MIN. FLOOR CLEARANCE AT SHOWER o� STANDARD ROLL IN SHOWER PLAN STANDARD ROLL -IN ACCESSIBLE SHOWER REMOVABLE BATHROOM CABINET ISOMETRIC EQ t EQ 1 1/2" CURTAIN ROD SHOWER DEPTH VARIES RE: UNIT PLANS END WALL ELEVATION z z O U z O Z O w Z m Lu m m m ¢ Q m m c(9 (� < z 0 ch x W x 0 O z Z) U m Lu O 2 m K Lu 0 O 2 m K O m J O m f - Z O U O O W Lu Lu 0 O 2 Lu > O m M v ro m co K U0 OLL =: = Urnw Z— Lu FSO Z ,n HAND-HELD SHOWER & CONTROLS 16" - 27" FROM EDGE OF SEAT WALL 4 LU m m LU O x m DOORS. rm o 0 F - - -- -1 W PLAN DATES � ¢ > m z O I � U W = Lu J w W = Lu C/) Z O ¢ X CL Z) 0 mz Z) m m Lu _ U a Lux - Z m w cC w 3:z = U w x W W W O w F z w U z 0 (D OJ COORDINATE WATER FEED o� ¢ HOSE LOCATION WITH WINDOW io w EQ t EQ 1 1/2" CURTAIN ROD SHOWER DEPTH VARIES RE: UNIT PLANS END WALL ELEVATION z z O U z O Z O w Z m Lu m m m ¢ Q m m c(9 (� < z 0 ch x W x 0 O z Z) U m Lu O 2 m K Lu 0 O 2 m K O m J O m f - Z O U O O W Lu Lu 0 O 2 Lu > O m M v ro m co K U0 OLL =: = Urnw Z— Lu FSO Z ,n HAND-HELD SHOWER & CONTROLS 16" - 27" FROM EDGE OF SEAT WALL 4 LU m m LU O x m DOORS. rm o 0 F - - -- -1 PLAN DATES - - - -----------J J_ I � U J uj a C/) JT ;ABINETo D W WINDOW, WHERE OCCURS. z 0 (D OJ COORDINATE WATER FEED Lu W N HOSE LOCATION WITH WINDOW C w "wmO ADD BLOCKING THIS LOCATION Q � M FOR FUTURE INSTALLATION OF x LQ 0)() SHOWER SEAT 11 SHOWER WIDTH VARIES RE: UNIT PLANS CONTROL WALL ELEVATION hK Cp�o ERIC C o E 4? 174 W= Lu Lu 0 O 0 Lu a JT CTION o 0 W PLAN DATES RANCE J_ I � U S uj a C/) JT ;ABINETo `� W O z 0 (D OJ Q Lu W N LU0 w "wmO Q � M w x LQ 0)() 11 W< T,, coLo V J z z O U -z O m Z O w Z m E] m m mm ¢ Q m m c�9 (7 2 z _o ch / pbott Asso 6�9� caeN\ 0 c \an9 DN`s• J 0 W J_ I m uj C/) co Lij O co Q LU0 Q LLJ w co z W< coLo 0 U(�:m 19-016 69:Iq011r►Co] A3-606 a 0 N (`� (`� O N O N r N V a N (`� (`� O N O N r N V Q N N M M O r r N O N ti N I LEVEL 2 - PROPOSED FINISH PLAN 1/811 = 1'-0" CORRIDOR FLOORING SCHEDULE ey Description Manufacture Series Pattern Color Size Comments 1 OVERALL ACCENT SHAW CONTRACT ACTIVE ADVANCE TILE 'ABILITY' 12" x 48" a O FLOORING O — 00 2 UNIT ENTRY SHAW CONTRACT ACTIVE DASH TILE 'ABILITY' 12" x 48" TILE TO BE CUT ACCENT COLOR 2 O w M OM v O DOWN TO 12" x 24" 3 UNIT ENTRY SHAW CONTRACT ACTIVE TRACK TILE 'ABILITY' 12" x 48" TILE TO BE CUT c ACCENT COLOR 2 W U) DOWN TO 12" x 36" JY JY LEVEL 1 - PROPOSED FINISH PLAN 1/811 = 1'-0" CPT -1 5' - 4" NIT ENTRY ACC T FLOOR PATTERN ALIGN TO EDGE DOOR FRAME 3'-4" 1 2'-0" CPT -1 CPT -1 —F PT CPT -1 CPT -2 CPT -1 CPT -1 UNIT ENTRY ACCENT FLOOR PATTERN OVERALL ACCENT FLOORING PATTERN CPT -1 UNIT ENTRY - TYPICAL FLOOR PATTERN 1/2" = 1'-0" hK Cp�o ERIC C o F -- LU J) 0 O 0 LU 0 a 0 74 PLAN DATES / pbotl Asso 6�9� caeN\ / O C \an9 DN`s• �� V Z a Z .1 n J a O O — 00 z�(D M� W U W 0 N • �--� I o °co W O w M OM v O r ^T V J Q / pbotl Asso 6�9� caeN\ / O C \an9 DN`s• �� V Z Z .1 n J O O — J M� W Illy I O W Illy Q 00 O 0 U c D W U) ;O � Q LU (D J � co i] FyW Z W< co Qrn = (D 0 19-016 69:IqM11r►C•a A3-801 PENDATNT ACCENT LIGHT TO REPLACE EXISTING FIXTURE AT ATRIUM BALCONY BALCONY (N) CELING MOUNTED LIGHT (TYP.) LEVEL 2 RCP 1/811 = 1'-0" BALCONY BALCON� WALL MOUNTED LIGHT (TYP.) BALCONY Mo _< WALL MOUNTED LIGHT TYP s°` (TYP.) ,sD- - - -- - - - - - - - - - - - - - - -TTI- - - - LEVEL 1 RCP 1/811 = 1'-0" Te 0 DUPLEX OUTLET SINGLE POLE LIGHT SWITCH O• SMOKE DETECTOR SD `Q0( O• TT CMD - 00 UNIT 102 SURFACE MOUNTED LIGHT FIXTURE UNIT 104 UNIT 106 3:- PL PENDANT LIGHT FIXTURE IT"108- "UNIT UNIT 110. . WO w UNIT TYPE 3 2.4 - 00 Oo M Loo T UNIT TYPE: 3-2.1 UNIT TYPE: 3 2.1 V J UNIT TYPE: 3 2.1 O UNIT TYPE: /1 TYPE A' QW -. RE: 4 /A3 303 ,' 0 - „ RE: 4 /A3-303308 /1 Lu Q I co RE: 3 /A3-307 ;;' W 0 U��m it 17 LEVEL 1 RCP 1/811 = 1'-0" hK Cp�o ERIC C o IT - Lu U) 0 0 0 Lu ¢ 0 a N O N 74 PLAN DATES ELECTRICAL SYMBOLS 0 DUPLEX OUTLET SINGLE POLE LIGHT SWITCH O• SMOKE DETECTOR SD `Q0( O• CARBON MONOXIDE DETECTOR CMD - 00 WALL MOUNTED EXIT SIGN SURFACE MOUNTED LIGHT FIXTURE o WALL MOUNTED LIGHT FIXTURE 3:- PL PENDANT LIGHT FIXTURE hK Cp�o ERIC C o IT - Lu U) 0 0 0 Lu ¢ 0 a N O N 74 PLAN DATES / pbotl Asso 6�9� caeN\ / O C \an9 DN`s• ) c Z a c/)V Q a z a Lu U `Q0( m - 00 z 0 �D OJ o W N n/ N M WO w M O 00 Oo M Loo T M V J / pbotl Asso 6�9� caeN\ / O C \an9 DN`s• ) c Z c/)V Q a z Lu U m ry i O n/ N M LL M O O U M D O W /1 I..L QW Q J 0 - z W /1 Lu Q I co ui W 0 U��m 19-016 69:Iq�r►C•] A3-802 Q N M CM M O r N O N I - C14 rLHJ I IU LHIVIINH I ED COUNTER TOPS NEW BLACK DISHWASHER TUB/SHOWER W/ TILE /A lon J Ill NEW STAINLESS STEEL SURROUND W/ Luo / / A / A / CEMENTITIOUS BACKER DROP-IN SINGLE -BOWL SINK �/ / Q LU I BOARD AT TUB/SHOWER QF CD( NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE w� � NEW PORCELAIN TOILET, W/ SINGLE FAUCET HOLE OP / WHITE NEW BLACK ELECTRIC RANGE PLAN DATES U I-� BLIND CORNER CABINET NEW CHROME TOILET PAPER c� ERIC C o FL HOLDER REQ'D IN TYPE'A' UNITS. E 1 NEW FRAMELESS, MIRRORED MEDICINE CABINETS. 4 174 NEW VANITY LIGHT FIXTURE NEW CHROME SHOWER ROD NEW DROP-IN PORCELAIN D A SINK BOWL, WHITE NEW CHROME ROBE HOOK a NEW CHROME TOWEL BAR TUB/SHOWER W/ TILE NEW CHROME HAND TOWEL ,' NEW CHROME HAND TOWEL z SURROUND W/ AR BAR >_ CEMENTITIOUS BACKER LHSTIC LAMINATED =r BOARD AT TUB/SHOWER C DOUNTER TOPS oQ o TUB/SHOWER W/ TILE SURROUND W/ 00 CEMENTITIOUS BACKER ,x BOARD AT TUB/SHOWER 3' 2' - 6" 3' I 5' -0" ♦' UNIT 3-2.5 - BATHROOM 4 UNIT 3-2.5 - BATHROOM 3 UNIT 3-2.5 - BATHROOM 2 UNIT 3-2.5 -BATHROOM 1 Lu 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" �`JJ 1/4" = 1'-0" PROVIDE 6" TRIM BOARD TO COVER GAP BETWEEN TOP OF CABINET AND CEILING w J) FILLER PROVIDE 6" TRIM BOARD TOO NEW BLACKTOP -FREEZER REFRIDGERATOR Z0 O CORNER 2' - 3" 2' - 0' 2' - COVER GAP BETWEEN TOP 3" FI 3' - 3" 21- 6" 21- 6" 1' - 7 1/ ' NEW BLACK OVER -RANGE a w w C;ARINFT OF CABINET AND CEILING ,,,,,_,,,.,., ,- - rLHJ I IU LHIVIINH I ED COUNTER TOPS NEW BLACK DISHWASHER /A lon J Ill NEW STAINLESS STEEL Luo / / A / A / DROP-IN SINGLE -BOWL SINK �/ / Q LU I NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE w� � o o W/ SINGLE FAUCET HOLE V / NEW BLACK ELECTRIC RANGE PLAN DATES U I-� rLHJ I IU LHIVIINH I ED COUNTER TOPS NEW BLACK DISHWASHER 2' _6 1�-71/ 1-1 <0 I-- 00 UNIT 3-2.5 - KITCHEN 2 UNIT 3-2.5 - KITCHEN 1 � wo8(D 1/4" = 1'-0" 1/4" = 1'-0" • r� U 0000 W O w O o M 3-2.5 INTERIOR UNIT ELEVATIONS x O v J Qtl es pbotl Asso 6�9� caeN\ NEW CHROME SHOWER ROD NEW VANITY LIGHT FIXTURE NEW CHROME TOWEL BAR NEW FRAMELESS, MIRRORED �''7diry9 REPLACE ALL WALL TILE IN MEDICINE CABINETS. SHOWER. REFINISH EXISTING REPLACE ALL WALL TILE IN M TUB WHERE REQ'D. SHOWER. REFINISH EXISTING SEE FINISH SCHEDULES FOR TUB WHERE REQ'D. Inr TUB AND SHOWER GRAB BAR ° 7 LOCATION SEE FINISH SCHEDULES FOR f � Z TUB AND SHOWER GRAB BAR r<F HEW CHROME TOILET PAPER _ LOCATION ER NEW PORCELAIN TOILET, WHITE J z 6 UNIT 3-2.4 (TYPE A) - BATHROOM 4 5UNIT 3-2.4 (TYPE A) - BATHROOM 3 UNIT 3-2.4 (TYPE A) - BATHROOM 2 UNIT 3-2.4 (TYPE A) - BATHROOM 1 D O_ 1/411=11-011 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" Q I PROVIDE 6" TRIM BOARD TO Lu COVER GAP BETWEEN TOP w J PROVIDE 6" TRIM BOARD TO OF CABINET AND CEILING w COVER GAP BETWEEN TOP SIDE-BY-SIDE M OF CABINET AND CEILING REFRIDGERATOR/FREEZER O O NEW STAINLESS STEEL W/ WATER & ICE DISPENSER DROP-IN SINGLE -BOWL SINK @ ALL TYPE'A' UNITS. 0 FILLER W/ SINGLE FAUCET HOLE MICROWAVE TO BE 6" 2' - 0" 2' 6" 2' - 6" ORNE MOUNTED UNDER 34" 1' -L21-611L112 0 COUNTER TOP @ ALL TYPE 'A' in ' U z D /A lon J Ill L Luo / / / v / � o �/ / Q LU I 2' _6 1�-71/ 1-1 <0 I-- 00 UNIT 3-2.5 - KITCHEN 2 UNIT 3-2.5 - KITCHEN 1 � wo8(D 1/4" = 1'-0" 1/4" = 1'-0" • r� U 0000 W O w O o M 3-2.5 INTERIOR UNIT ELEVATIONS x O v J Qtl es pbotl Asso 6�9� caeN\ NEW CHROME SHOWER ROD NEW VANITY LIGHT FIXTURE NEW CHROME TOWEL BAR NEW FRAMELESS, MIRRORED �''7diry9 REPLACE ALL WALL TILE IN MEDICINE CABINETS. SHOWER. REFINISH EXISTING REPLACE ALL WALL TILE IN M TUB WHERE REQ'D. SHOWER. REFINISH EXISTING SEE FINISH SCHEDULES FOR TUB WHERE REQ'D. Inr TUB AND SHOWER GRAB BAR ° 7 LOCATION SEE FINISH SCHEDULES FOR f � Z TUB AND SHOWER GRAB BAR r<F HEW CHROME TOILET PAPER _ LOCATION ER NEW PORCELAIN TOILET, WHITE J z 6 UNIT 3-2.4 (TYPE A) - BATHROOM 4 5UNIT 3-2.4 (TYPE A) - BATHROOM 3 UNIT 3-2.4 (TYPE A) - BATHROOM 2 UNIT 3-2.4 (TYPE A) - BATHROOM 1 D O_ 1/411=11-011 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" Q I PROVIDE 6" TRIM BOARD TO Lu COVER GAP BETWEEN TOP w J PROVIDE 6" TRIM BOARD TO OF CABINET AND CEILING w COVER GAP BETWEEN TOP SIDE-BY-SIDE M OF CABINET AND CEILING REFRIDGERATOR/FREEZER O O NEW STAINLESS STEEL W/ WATER & ICE DISPENSER DROP-IN SINGLE -BOWL SINK @ ALL TYPE'A' UNITS. 0 FILLER W/ SINGLE FAUCET HOLE MICROWAVE TO BE 6" 2' - 0" 2' 6" 2' - 6" ORNE MOUNTED UNDER 34" 1' -L21-611L112 0 COUNTER TOP @ ALL TYPE 'A' in ' U z D /A /AIll Ill 11rv7o, i� "vm"' w •• •,. COUNTER TOPS DROP-IN RANGE W/ FRONT CONTROLS & HOOD ABOVE Luo / / / v / � o �/ / Q LU I NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE w� � o o V / NEW BLACK ELECTRIC RANGE PLAN DATES U I-� BLIND CORNER CABINET 2' _6 1�-71/ 1-1 <0 I-- 00 UNIT 3-2.5 - KITCHEN 2 UNIT 3-2.5 - KITCHEN 1 � wo8(D 1/4" = 1'-0" 1/4" = 1'-0" • r� U 0000 W O w O o M 3-2.5 INTERIOR UNIT ELEVATIONS x O v J Qtl es pbotl Asso 6�9� caeN\ NEW CHROME SHOWER ROD NEW VANITY LIGHT FIXTURE NEW CHROME TOWEL BAR NEW FRAMELESS, MIRRORED �''7diry9 REPLACE ALL WALL TILE IN MEDICINE CABINETS. SHOWER. REFINISH EXISTING REPLACE ALL WALL TILE IN M TUB WHERE REQ'D. SHOWER. REFINISH EXISTING SEE FINISH SCHEDULES FOR TUB WHERE REQ'D. Inr TUB AND SHOWER GRAB BAR ° 7 LOCATION SEE FINISH SCHEDULES FOR f � Z TUB AND SHOWER GRAB BAR r<F HEW CHROME TOILET PAPER _ LOCATION ER NEW PORCELAIN TOILET, WHITE J z 6 UNIT 3-2.4 (TYPE A) - BATHROOM 4 5UNIT 3-2.4 (TYPE A) - BATHROOM 3 UNIT 3-2.4 (TYPE A) - BATHROOM 2 UNIT 3-2.4 (TYPE A) - BATHROOM 1 D O_ 1/411=11-011 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" Q I PROVIDE 6" TRIM BOARD TO Lu COVER GAP BETWEEN TOP w J PROVIDE 6" TRIM BOARD TO OF CABINET AND CEILING w COVER GAP BETWEEN TOP SIDE-BY-SIDE M OF CABINET AND CEILING REFRIDGERATOR/FREEZER O O NEW STAINLESS STEEL W/ WATER & ICE DISPENSER DROP-IN SINGLE -BOWL SINK @ ALL TYPE'A' UNITS. 0 FILLER W/ SINGLE FAUCET HOLE MICROWAVE TO BE 6" 2' - 0" 2' 6" 2' - 6" ORNE MOUNTED UNDER 34" 1' -L21-611L112 0 COUNTER TOP @ ALL TYPE 'A' in ' U z D /A /AIll Ill 11rv7o, i� "vm"' w •• •,. COUNTER TOPS DROP-IN RANGE W/ FRONT CONTROLS & HOOD ABOVE / / / v / � o �/ / Q LU I 30" MIN. CLEAR WORKSPACE ALL TYPE W UNITS. V / ,' e LO FL REQ'D IN TYPE'A' UNITS. 1 PROVIDE REMOVABLE BLIND CORNER CABINET CABINET FACE & EXTEND " _ w �a M FINISH FLOOR TO FACE OF PROVIDE SINK DRAIN ON oC �jC�� WALL. PAINT WALL BEHIND LEFT-HAND SIDE AT KITCHEN F/T\�F\ I� CABINET. SINK @ALL TYPE UNITS.F7 Lo LLQ 0 PROVIDE REMOVABLE RECESS GARBAGE DISPOSAL U m m CABINET FACE SINK AIR SWITCH INTO 6" 2' - 0" 2' -A 2' - 6' CABINET & EXTEND FINISH COUNTERTREACH RANOGES @ AL P WITHINLTD PE REMOVABL REMOVABLE FLOOR TO FACE OF WALL BEYOND. PAINT WALL A UNITS. 1 9-01 6 BEHIND. SHEET NO. UNIT 3-2.4 (TYPE A) - KITCHEN 2 UNIT 3-2.4 (TYPE A) - KITCHEN 1 A3-804 2 1/4" = 1'-0" �� 1/4" = 1'-0" 3-2.4 (TYPE A) INTERIOR UNIT ELEVATIONS REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING pF C of TUB WHERE REQ'D. �F �9 REPLACE ALL WALL TILE IN 90 SHOWER. REFINISH EXISTING NEW VANITY LIGHT FIXTURE ERIC C TUB WHERE REQ'D. NEW FRAMELESS, MIRRORED - 'E MEDICINE CABINETS. ° NEW FRAMELESS, MIRRORED 4 174 NEW CHROME TOWEL BAR MEDICINE CABINETS.I:]- NEW l V� PLASTIC LAMINATED BAR CHROME HAND TOWEL 0 A COUNTERTOPS NEW PORCELAIN TOILET, 0 _ NEW BASE CABINETS W/ WHITE HOLDER NEW CHROME TOILET PAPER 0� e o CABINET PULLS i� NEW CHROME TOILET PAPER NEW PORCELAIN TOILET, HOLDER oQ WHITE 3' - 0" ' oz 4'_6"7 71 �v w� �o ,x UNIT 3-2.3 - BATHROOM ELEVATION 3 UNIT 3-2.3 - BATHROOM ELEVATION 2 UNIT 3-2.3 - BATHROOM ELEVATION 1 aI 1/4" = 1'-0" 1/4" = 1'-0" �1/4" = 1'-0" V I Lu IrLu FILLER 2' - 6" 2' - 6" 2' - 9" 3' - 0" FILLER 1' - 6" 2' - 0" 2' - 6" 2' - 0" PROVIDE 6" TRIM BOARD TO z0 U COVER GAP BETWEEN TOP NEW UPPER CABINETS W/ OF CABINET AND CEILING NEW BLACK OVER -RANGE a Lu CABINET PULLS MICROWAVE Y I- NEW STAINLESS STEEL > o NEW UPPER CABINETS W/ o NEW BLACK TOP -FREEZER U) o DROP-IN SINGLE -BOWL SINK CABINET PULLS o REFRIDGERATOR p a_ W/ SINGLE FAUCET HOLE / / 0 TILE BACKSPLASH AT KITCHEN PLASTIC LAMINATED oN COUNTERTOPS L7 PLASTIC LAMINATED L COUNTER TOPS Q No NEW BASE CABINETS W/ o RANGNEW BASE CABINETS W/ CABINET PULLS CABINET PULLS \ j e j PLAN DATES NEW BLACK DISHWASHER ° h BLACK ELECTRIC r 1 6"� 2' - 0" � 2' - 6" ' - 311 FILLER�� � 2'-6" 2- - 9" 3--l" w UNIT 3-2.3 - KITCHEN ELEVATION 2 R UNIT 3-2.3 - KITCHEN ELEVATION 1 00 zO� -011 • rIU O6.0 V W O w o O � M 3-2.3 INTERIOR UNIT ELEVATIONS x Lo o 4-j v J Qtl es pbotl Asso 6�9� caeN\ NEW VANITY LIGHT FIXTURE e c i i NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND [JF--�* WHITE z MD O W 7 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 4 6 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 3 5 UNIT 3-2.1 and 3-2.2 -BATHROOM ELEVATION 2 Q 4 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 1 , 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" > Lu W J Lu Q Mo O D 0 LU NEW UPPER CABINETS W/ 2'-6" 2'-6" 1'-6" 3'-0" 3'-0" y 3'-0" y2'-0" y1'-6" �f w O CABINET PULLS niMni ❑i nnu n%/I=D onnin_I= SO FIT NEW UPPER CABINETS W/ MICROWAVE V J NEW FRAMELESS, MIRRORED MEDICINE CABINETS ` i i i U 9 DS.o Lu (D z NEW CHROME SHOWER ROD— WHITE z MD O W 7 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 4 6 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 3 5 UNIT 3-2.1 and 3-2.2 -BATHROOM ELEVATION 2 Q 4 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 1 , 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" > Lu W J Lu Q Mo O D 0 LU NEW UPPER CABINETS W/ 2'-6" 2'-6" 1'-6" 3'-0" 3'-0" y 3'-0" y2'-0" y1'-6" �f w O CABINET PULLS niMni ❑i nnu n%/I=D onnin_I= SO FIT NEW UPPER CABINETS W/ MICROWAVE V J NEW FRAMELESS, MIRRORED MEDICINE CABINETS ` CABINET PULLS NEW STAINLESS STEEL 9 DS.o Lu (D z NEW CHROME SHOWER ROD— N BAR CHROME HAND TOWEL i DROP-IN SINGLE BOWL' SINK— tnu cinir_i rni ir�T uni � III U ^ vw, "ITI > Q co Q N = D NEW CHROME TOWEL BAR N r n WINES PLASTIC LAMINATED V COUNTER TOPS 7 NEW MULTI -PIECE NEW DROP-IN PORCELAIN FIBERGLASS TUB & SHOWER SINK BOWL, WHITE h Q SURROUND NEW PORCELAIN TOILET, WHITE z MD O W 7 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 4 6 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 3 5 UNIT 3-2.1 and 3-2.2 -BATHROOM ELEVATION 2 Q 4 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 1 , 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" > Lu W J Lu Q Mo O D 0 LU NEW UPPER CABINETS W/ 2'-6" 2'-6" 1'-6" 3'-0" 3'-0" y 3'-0" y2'-0" y1'-6" �f w O CABINET PULLS niMni ❑i nnu n%/I=D onnin_I= SO FIT NEW UPPER CABINETS W/ MICROWAVE V J z Q ` CABINET PULLS NEW STAINLESS STEEL Lu (D z NEW BLACK TOP -FREEZER v REFRIDGERATOR N o i DROP-IN SINGLE BOWL' SINK— tnu cinir_i rni ir�T uni � III U ^ vw, N PLASTIC LAMINATED PLASTIC LAMINATED v" COUNTER TOPS00 COUNTER TOPS NEW BLACK ELECTRIC \ NEW BLACK DISHWASHER RANGE L/JM7D NEW BASE CABINETS W/ NEW BASE CABINETS W/ CABINET PULLS CABINET PULLS ��1'_6" ���� 19-016 SHEET NO. UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 3 UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 1 31/4" = 1'-0=1'-°" A3-805 3-2.1 and 3-2.2 INTERIOR UNIT ELEVATIONS V J z Q Lu (D z o N < 0 �_ n U ^ vw, "ITI > Q co Q N = D WINES ���� 19-016 SHEET NO. UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 3 UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 1 31/4" = 1'-0=1'-°" A3-805 3-2.1 and 3-2.2 INTERIOR UNIT ELEVATIONS V J z Q Lu (D z o N < 0 �_ n U ^ vw, "ITI > Q co Q N = D ���� 19-016 SHEET NO. UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 3 UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 1 31/4" = 1'-0=1'-°" A3-805 3-2.1 and 3-2.2 INTERIOR UNIT ELEVATIONS NEW UPPER CABINETS W/ CABINET PULLS NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE PLASTIC LAMINATED COUNTER TOPS NEW BLACK DISHWASHER NEW BASE CABINETS W/ CABINET PULLS ' Iln' 5' - 0" CD�olp 11111■III■III,, I i p W LLI b �■■. NEW BLACK TOP -FREEZER � h��pF REFRIDGERATOR o c� ERIC C o PLASTIC LAMINATED O E COUNTERTOPS O ' A U) NEW VANITY LIGHT FIXTURE4 NEW UPPER CABINETS W/ �� _ L 174 NEW CHROME HAND TOWEL NEW FRAMELESS, MIRRORED _ NEW VANITY LIGHT FIXTURE D A NEW CHROME TOWEL BAR BAR MEDICINE CABINETS. RANGE 0 e 0 PLAN DATES NEW BASE CABINETS W/ NEW FRAMELESS, MIRRORED i NEW CHROME TOILET PAPER NEW CHROME TOWEL BAR PLASTIC LAMINATED MEDICINE CABINETS. U HOLDER COUNTERTOPS N i o NEW PORCELAIN TOILET, i o ro z _ WHITE NEW DROP-IN PORCELAIN e e W/ SINGLE FAUCET HOLE NEW MULTI -PIECE SINK BOWL, WHITE e i NEW MULTI -PIECE FIBERGLASS TUB & SHOWER FIBERGLASS TUB & SHOWER NEW BASE CABINETS W/ e ��_ NEW MULTI PIECE FIBERGLASS TUB &SHOWER oz oz SURROUND SURROUND CABINET PULLS SURROUND �o 00 N ,x 3 2 6 1 3 I S VI —' UNIT 3-1.2 — BATHROOM ELEVATION 4 UNIT 3-1.2 — BATHROOM ELEVATION 3 UNIT 3-1.2 — BATHROOM ELEVATION 2 )UNIT 3-1.2 — BATHROOM ELEVATION 1 11.1 io > 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" U�%� 1/4" = 1'-0" Lu FILLER FILLER 2'-0" 3'-0" 2'-0" 3'-0" 2'_3" 2'-6" 2'-3" 2'-0" w U) NEW UPPER CABINETS W/ z0 w O CABINET PULLS NEW UPPER CABINETS W/ CABINET PULLS NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/ SINGLE FAUCET HOLE PLASTIC LAMINATED COUNTER TOPS NEW BLACK DISHWASHER NEW BASE CABINETS W/ CABINET PULLS ' Iln' 5' - 0" MICROWAVE 11111■III■III,, I i p W LLI b �■■. NEW BLACK TOP -FREEZER � REFRIDGERATOR o O O PLASTIC LAMINATED O _ N NN COUNTERTOPS O ' A U) NEW BLACK OVER-RANGELu 5' - 0" MICROWAVE I i p W LLI b LLj NEW BLACK TOP -FREEZER � REFRIDGERATOR o O O PLASTIC LAMINATED O _ N NN COUNTERTOPS O ' A U) ; U z NEW UPPER CABINETS W/ �� _ L r 0 o NEW BLACK ELECTRIC D RANGE 0 e 0 PLAN DATES NEW BASE CABINETS W/ ° i CABINET PULLS U FILLER 3-0" � 2'-3" � 2'-6" �1'-3'� 3'-25/8" a 2'-0" 3' - 0" 2' - 0" 00 Q lUNIT 3-1.2 — KITCHEN ELEVATION 2 UNIT 3-1.2 — KITCHEN ELEVATION 1 z�(D �V/ 1/4" = 1'_0.. , % 1/4.. = 1'_0.. w OJ N �/ • r� U O 00 co WO w E -IO� o M 3-1.2 INTERIOR UNIT ELEVATIONS x O 4-j v J Qtl es pbotl Asso 6�9� caeN\ NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND NEW PORCELAIN TOILET, WHITE NEW VANITY LIGHT FIXTURE NEW VANITY LIGHT FIXTURE NEW FRAMELESS, MIRRORED MEDICINE CABINETS. NEW DROP-IN PORCELAIN SINK BOWL, WHITE NEW BASE CABINETS W/ CABINET PULLS NEW MULTI -PIECE FIBERGLASS TUB & SHOWER NEW FRAMELESS, MIRRORED = ' MEDICINE CABINETS. V NEW DROP-IN PORCELAIN v 7 SINK BOWL, WHITE v L PLASTIC LAMINATED Q COUNTERTOPS _ NEW MULTI -PIECE NEW BASE CABINETS W/ O e z FIBERGLASS TUB & SHOWER CABINET PULLS O SURROUND -3' 2'-6" 1'-3' — SURROUND 5' - 0" a I i UNIT 3-1.1 —BATHROOM ELEVATION 4 UNIT 3-1.1 —BATHROOM ELEVATION 3 UNIT 3-1.1 — BATHROOM ELEVATION 2 3 UNIT 3-1.1 — BATHROOM ELEVATION 1 W LLI b LLj 1/4" = 1'-0" J 1/4" = 1'-0" J 1/4" = 1'-0" 1/4" = 1'-0"M � Q O O NEW STAINLESS STEEL FILLER FILLER00 ORNE 3'-0" 2'-0" 3'-0" 2'-9" 2'-6" 3'-0" ORNE Q LU NEW UPPER CABINETS W/ ABINE CABINET PULLS ABINE ' A U) ; U z NEW UPPER CABINETS W/ �� _ NEW BLACK TOP -FREEZER � ..:' — 0 0 i h REFRIDGERATOR i o i i W/ SINGLE FAUCET HOLE pp i NEW FRAMELESS, MIRRORED = ' MEDICINE CABINETS. V NEW DROP-IN PORCELAIN v 7 SINK BOWL, WHITE v L PLASTIC LAMINATED Q COUNTERTOPS _ NEW MULTI -PIECE NEW BASE CABINETS W/ O e z FIBERGLASS TUB & SHOWER CABINET PULLS O SURROUND -3' 2'-6" 1'-3' — SURROUND 5' - 0" a I i UNIT 3-1.1 —BATHROOM ELEVATION 4 UNIT 3-1.1 —BATHROOM ELEVATION 3 UNIT 3-1.1 — BATHROOM ELEVATION 2 3 UNIT 3-1.1 — BATHROOM ELEVATION 1 W LLI b LLj 1/4" = 1'-0" J 1/4" = 1'-0" J 1/4" = 1'-0" 1/4" = 1'-0"M � Q O O NEW STAINLESS STEEL FILLER FILLER00 ORNE 3'-0" 2'-0" 3'-0" 2'-9" 2'-6" 3'-0" ORNE Q LU NEW UPPER CABINETS W/ ABINE CABINET PULLS ABINE ' A U) ; U z NEW UPPER CABINETS W/ �� _ NEW BLACK TOP -FREEZER � ..:' — CABINET PULLS i / NEW BLACKOVcn-m/AlTI MICROWAVE � � i� � 'J� LU NEW STAINLESS STEEL o NEW BLACK TOP -FREEZER j Z DROP-IN SINGLE -BOWL SINK h REFRIDGERATOR i o i W/ SINGLE FAUCET HOLE pp T Ld 00 N PLASTIC LAMINATED i PLASTIC LAMINATED COUNTER TOPS W Q M COUNTER TOPS 0 NEW BLACK ELECTRIC io 00 LLI (D NEW BLACK DISHWASHER RANGE i i o = 0 o e �n NEW BASE CABINETS W/ NEW BASE CABINETS W/ � N � m CABINET PULLS CABINET PULLS 2'-3" 3'-0" 2'-0" 3'-0" 2'-9" 2'-6" 1'-6" 3'-75/8" - 016 �UNIT 3-1.1 — KITCHEN ELEVATION 2 UNIT 3-1.1 — KITCHEN ELEVATION 1 SHEET NO. A3-806 3-1.1 INTERIOR UNIT ELEVATIONS /I\\— a M M M 0 N O N r N V 24 iA O O N O N N T GENERAL NOTES 1. LIVE LOADS USED IN DESIGN: A. ROOF 30 PSF (35 PSF GROUND) B. TYPICAL FLOOR 40 PSF (RESIDENTIAL) 100 PSF COMMON AREAS AND EXIT FACILITIES C. WIND 3 SECOND GUST 115 MPH (ULT) EXPOSURE B E. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE. F. CODE USED IN DESIGN: 2012 IBC. 2. FOUNDATIONS A. MAXIMUM SOIL DESIGN PRESSURE 3000 PSF. MINIMUM SOIL DESIGN PRESSURE 1000 PSF. B. CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS IN SOILS REPORT NO.25195383 BY TERRACON DATED JANUARY 22, 2020. C. ALL FOOTING BEARING ELEVATIONS SHOW AR ASUMED. EXACT BEARING ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS SHALL BE A MINIMUM OF 36" BELOW EXTERIOR GRADE. D. ALL FOOTINGS ARE TO PLACED ON FIRM, UNDISTURBED, NATURAL SOIL OR PROPERLY COMPACTED BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL SHALL BE COMPACTED TO 95% (MINIMUM) MODIFIED PROCTOR DENSITY PER ATSM D1557 UNLESS OTHERWISE RECOMMENDED IN T SOILS REPORT. IF SOFT SPATS ARE ENCOUNTERED REMOVED SOIL AND RECOMPACT WITH THE APPORVED FILL (RE: SOIL REPORT FOR DESCRIPTION OF BEARING SOIL.) E. CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRID LINES UNLESS NOTED OTHERWISE ON PLANS. F. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TEST ON COMPACTED FILL UNDER FOOTINGS AND INTERIOR SLABS -ON -GRADE. G. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETE SO THAT CONDITIONS MAY BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE. 3. SLAB ON GRADE A. THE PREPARATION OF THE SUBGRADE FOR THE SLAB ON GRADE SHALL BE IN STRICT ACCORDANCE WITH THE PROJECT SOILS REPORT REFERENCED ABOVE. THE CONTRACTOR SHALL DIRECT QUESTIONS REGARDING THE SUBGRADE PREPARATION REQUIREMENTS TO THE GEOTECHNICAL ENGINEER. 4. CONCRETE A. ALL CAST -IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT, STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS: CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ. FOOTINGS 3000 psi STD --- --- FOUNDATION WALLS 3000 psi STD --- --- INTERIOR SLABS ON GRADE 3000 psi STD 0.50 --- EXTERIOR CONCRETE (++) 4500 psi STD 0.45 6%-8% ++ MAXIMUM SLUMP SHALL NOT EXCEED 4". B. IF CONCRETE SUPPLIER PROPOSES USE OF FLYASH HE SHALL PROVIDE OWNER WITH LETTER INDICATING COST REDUCTION AT TIME OF BID. THE MODULUS OF ELASTICITY OF ALL CONCRETE SHALL EXCEED WC1.5 33 F'C (OR 57,000 F'C NORMAL WEIGHT CONCRETE). C. CONTRACTOR SHALL SAWCUT OR TROWELCUT JOINTS IN SLABS ON GRADE. JOINTS SHALL BE SPACED 15 FEET AND SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X 3/16" WIDE WITHIN 12 HOURS AFTER POURING. CARRY ALL SLAB REINFORCEMENT THROUGH JOINT. D. SLABS, TOPPING, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE ENGINEER. E. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OF CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER. 5. REINFORCEMENT A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BE LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER. C. REINFORCEMENT PROTECTION UNLESS NOTED OTHERWISE: 1. CONCRETE POURED AGAINST EARTH 3" 2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH) 2" 3. COLUMNS AND BEAMS (TIE BARS) 1-1/2" 4. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4" D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH SECTIONS 7.5, 7.6 AND 7.7 OF ACI 318, LATEST EDITION. E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND SHALL BE A MINIMUM OF 80 BAR DIAMETERS FOR #7 AND #8 REINFORCEMENT UNLESS NOTED OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS. F. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS IN CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY AT EACH CORNER. G. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED AS FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS. 6. STRUCTURAL STEEL A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICH SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B. LATEST EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION. MISCELLANEOUS EMBEDDED ITEMS SHALL BE A36 STEEL. B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307 UNLESS NOTED OTHERWISE. C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION." D. EXCEPT WHERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. WHEN LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM AND SPAN FOR NON -COMPOSITE MEMBERS. E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS -D1.1. F. MINIMUM WELDS TO BE PER AISC TABLE 32.4 BUT NOT LESS THAN 3/16" CONTINUOUS FILLET UNLESS NOTED OTHERWISE. G. FOR ALL BEAM/COLUMN OR BEAM/BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORT SLOTS IN CONNECTION MEMBER ONLY (WT -SECTIONS, ANGLES OR SHEAR PLATES). 7. NON -SHRINK GROUT A. NON -SHRINK GROUT SHALL BE PROVIDED: 1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS. 2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRY SUPPORTS. 3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE. 8. WOOD A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY HEM FIR GRADED BY WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL BUILDING CODE AS FOLLOWS: 2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 675 PSI 2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 850 PSI 5" THICK - 5" AND WIDER NO. 1 Fb = 1050 PSI NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITIVE USES PRIOR TO ALLOWABLE STRESS INCREASES. B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLEDIPPED OR BETTER). C. TREATED SILL PLATE LUMBER MAY BE HEM -FIR, STRUCTURAL #1 GRADE. D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X WOOD JOISTS. SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS IS REQUIRED. E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE TABLE 2304-9.1 UNLESS NOTED OTHERWISE. HE F. LAMINATED BEAMS 1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH AT 12 PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL SIZES SHOWN ARE NET. 2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AITC. 3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUS MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS. MEMBERS SHALL BE DESIGNED WITH ZERO CAMBER WITH TOP SURFACE CLEARLY STAMPED ON EACH MEMBER. G. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD. 1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD ASSOCIATION. 2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE -TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE WEATHER SHALL BE OF THE EXTERIOR TYPE. 3. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG INTERMEDIATE SUPPORTS. 4. FOR ROOF USE 7/16" (24/16 SPAN RATING) EXPOSURE I SHEATHING NAILED WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG INTERMEDIATE SUPPORTS. 5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 7/16" EXPOSURE I PLYWOOD OR OSB SHEATHING NAILED WITH 8d NAILS AT 3" ON CENTER ALONG PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES SHALL BE BLOCKED. 6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED. 7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS. H. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS AND SHALL BE "BCI JOIST" AS MANUFACTURED BY BOISE CORPORATION. ALTERNATES SHALL BE REVIEWED BY THE ENGINEER. TO BE CONSIDERED, ALTERNATES SHALL HAVE A LOAD CAPACITY IN BENDING, SHEAR AND DEFLECTION EQUAL TO OR GREATER THAN THE SIZE SHOWN ON THE DRAWINGS. WEB BLOCKING AND BRIDGING TO BE AS REQUIRED BY THE JOIST MANUFACTURER. I. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI. BUILT UP MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR 5 1/4" WIDE MEMBERS. J. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO FULFILL STRESS REQUIREMENTS AND/OR LOADS NOTED ON DRAWINGS. SHOP DRAWINGS SHALL INCLUDE CALCULATIONS AND BEAR THE STAMP OF A REGISTERED ENGINEER. PROVIDE BRIDGING AND BLOCKING PER MANUFACTURER'S RECOMMENDATIONS UNLESS OTHERWISE NOTED. PROVIDE CONSTRUCTION BRACING AS REQUIRED ERECTION NOTE: CENTER WALL STUDS UNDER CENTER OF TRUSS LOCATIONS. 9. NON-STRUCTURAL ELEMENTS A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND OTHER STRUCTURAL MOVEMENTS. B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED UNRESTRAINED UNLESS NOTED OTHERWISE. 10. MASONRY A. ALL MASONRY CONSTRUCTION REQUIRES SPECIAL INSPECTIONS PER CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE. B. CONCRETE BLOCK UNITS SHALL CONFORM TO ASTM C90, GRADE N. BRICK SHALL FULFILL ASTM C62, C216 OR C652. MORTAR SHALL BE ASTM C270 TYPE S OR M. C. MASONRY SHALL CONSIST OF CONCRETE BLOCK WITH A MINIMUM COMPRESSIVE STRENGTH OF F'm OF 1500 PSI BASED ON NET AREA. D. WALLS SHALL BE REINFORCED HORIZONTALLY AT 16" ON CENTER WITH 9 GAGE MINIMUM LADDER -TYPE REINFORCEMENT MEETING ASTM A82 MASONRY WALL REINFORCEMENT. HORIZONTAL REINFORCING SHALL BE CONTINUOUS AROUND CORNERS. E. UNLESS NOTED OTHERWISE, MASONRY WALLS SHALL ALSO BE REINFORCED WITH ONE #5 VERTICALLY AT WALL ENDS, CORNERS, EACH SIDE OF DOOR OR WINDOW OPENINGS AND AT NOT OVER 4'-0" FEET ON CENTER TYPICALLY. REINFORCEMENT SHALL BE FULLY GROUTED IN PLACE. GROUT SHALL DEVELOP 3000 PSI IN 28 DAYS AND MEET ASTM C476. F. ALL CMU WALLS REQUIRE A MINIMUM OF 2-#5 IN BOND BEAM ABOVE ALL DOORS AND WINDOWS, AT FLOOR AND ROOF LINES, AND TOP OF PARAPETS UNLESS OTHERWISE NOTED. G. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION JOINT LOCATIONS. H. FILL ALL VOIDS AND BLOCK CELLS SOLIDLY WITH ASTM C476 GROUT FOR A DISTANCE OF 24" BENEATH AND A MINIMUM OF 16" EACH SIDE OF ALL BEAM REACTIONS OR OTHER CONCENTRATED LOADS UNLESS NOTED OTHERWISE. I. CMU SHALL BE FULLY GROUTED BELOW GRADE. J. PROVIDE A THICKENED CONCRETE SLAB UNDER ALL MASONRY PARTITION WALLS. SEE ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF WALLS AND FOR OPENINGS, ALL OF WHICH REQUIRE LINTELS. SEE LOOSE LINTEL SCHEDULE FOR FRAMING OVER NON-BEARING OPENINGS IF NOT SHOWN ON STRUCTURAL DRAWINGS. SEE MECHANICAL DRAWINGS FOR THOSE OPENINGS WHICH REQUIRE LINTELS. K. ALL MULTIPLE WYTHE MASONRY WALLS SHALL BE GROUTED SOLID BETWEEN EACH WYTHE WITH ASTM C476 GROUT. L. WHERE MASONRY LINTELS CROSS EXPANSION CONTROL JOINTS IN MASONRY, INSTALL LINTELS SO THAT THE LINTEL MAY SLIDE ON ONE END. M. PROVIDE MASONRY TIES WHERE MASONRY ABUTS CONCRETE. 11. GENERAL A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS. B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY. C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF HIS ITEMS. D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL, MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDED ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLED BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36. E. PROVIDE ASPHALTIC MASTIC -COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH. F. SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL STRUCTURAL STEEL, WOOD TRUSSES. THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TO WRITTEN REVIEW OF SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE CONTRACTOR. G. WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS. H. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE. I. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD AND ARCHITECTURAL DRAWINGS. J. PRE -MANUFACTURED STAIRS, HANDRAILS, AND GUARDRAILS NOTED ON PLAN SHALL HAVE ALL ENGINEERING, DESIGN AND DETAILING PROVIDED BY STAIR DESIGNER AND SHALL BE SUBMITTED FOR ARCHITECTS REVIEW BEARING THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO. STAIRS SHALL BE DESIGNED TO SUPPORT A LIVE LOAD OF 100 PSF. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS AND CRITERIA. (E) 2X1( JOISTS (E) STE�� SECTION 3 314" = 1'-0" SECTION 4 3/4" = 1'-0" I I I I I I I I I (E) BEARING WALL TO REMOVE I I I I I I I I I v SECTION 5 3/4" = 1'-0" (E) BEARING WALL (E) FLOOR JOIST WITH U28 HANGER (SHORE AS REQUIRED) NEW STEEL BEAM BLOCK WEB SOLID Y L i L c 3/16" MAX X T/4 DEEP _ 3/4" MIN. SAW CUT NOTE: RE: PLANS AND GENERAL NOTES FOR SPACING OF CONTROL JOINTS ss- NOTE: RE: SOILS REPORT FOR OVER EXCAVATION REQUIRED BELOW INTERIOR SLAB -ON -GRADE. 5/8"0 X 18" SMOOTH ROD AT 12". GREASE ONE END - TYPICAL SAW CUT N H DOWELED SLAB JOINT DETAIL 1 3/4" = 1'-0" #5 VERTICAL (TYP.) DEVELOPMENT LAP LENGTH ea a ° •d = HORIZONTAI REINFORCEI w (TYP.) J #5 VERTICAL (TYP.) ol DEVELOPMENT 10 LAP LENGTH #5 VERTICAL (TYP.) OR MATCH VERTICAL WALL REINFORCING LAP LENGTH it = 0 90 HOOK `w = 1 C7 O 0 a � C7 W U O W L a Z O U ° a W > a a ° CORNER INTERSECTION CORNER DETAIL 2 314" = 1'-0" RE: PLAN PROVIDE STANDARD HOOK e a' d 1I - e e . de• TYPICAL FOOTING REINFORCEMENT No ' II LAP LENGTH RE: GENERAL NOTES ih TYPICAL STEPPED FOOTING DETAIL 3/4" = 1'-0" BARS TO MATCH TYPICAL FOOTING REINFORCEMENT W d U M W z*� u M (DZ U) Z O U rw V 0 z 'Q V ) w O M Z O J c w Lu OZ >v w Q rwn 0 �V 1 0 M L.L V Z Q L0 w S"') 2 - W 19-016 SHEET NO. S3-100 0 O 0 U O Z O U w U cma o a Z CD 0 O 0001 N N N N 0 O O PLAN DATES '*..0 U '..j F-=1 O 0 D Ix9 O [ T L DO04 0000N W O W o 0O M 0 F--�1 x O Lo C9 U Lo � VJ r x w CAA 0 M (DZ U) Z O U rw V 0 z 'Q V ) w O M Z O J c w Lu OZ >v w Q rwn 0 �V 1 0 M L.L V Z Q L0 w S"') 2 - W 19-016 SHEET NO. S3-100 VAF 24 Lo 0 CD O N O N N T SECTION 1 3/4" = 1'-0" IES LEVEL 2 FRAMING PLAN 1/811=11-01, 11"rr vwrn 1 -uI-uw k i i 1 .) LtVtL "I/I-UUNUA I IUIN FLAIN I JQ'. - 1,-n,. = U k•. N W Z 0 0 ui U O 0 Z O O w U a 2 U o U) a Z w 0 O OIL) U 04 04 IN IN w �t to H N N o O O PLAN DATES Lo2r.n.- 00 9CD Q O T 00 00 N W O o0 M �O L� O� CAA 061 5/2uz0 M (DZ J m w M M O z � c Q � U) w0 > U aw 0 Q ooh C/) w �< Q� = o CU � 3: 19-016 SHEET NO. S3-101 24 iA 0 0 N 0 N rn N T LEVEL 2 DEMO PLAN 1/811=11-01, \ (E) STOOP AND STAIRS LEVEL 1 DEMO PLAN TO REMOVE (TYP.) 1/81, =1'-0" = U k•. N W Z 0 0 C6 U O Q Z O O w U a 2 U o U) a Z C/) Q O OIL) U 04 04 W co 0 o o PLAN DATES Lo2r.n.- 00 9CD 0 O T 00 00 N oU W O Q M �O L G` r CAA M 0 Z J m W co O U) CIDZ CY0 �U Qw 0 Q �C� p W p ooh w < � Q Lo= p 19-016 SHEET NO. S3 -101D HVAC, PLUMBING, ELECTRICAL, AND GENERAL CONTRACTOR COORDINATION SCHEDULE CATEGORY DESCRIPTION OF WORK FURNISHED BY MOUNTED BY WIRED BY NOTES LOCATING EXISTING UTILITIES EXTERIOR G.C. - - -HW UF- HOT WATER, UNDER FLOOR - - HW(E) INTERIOR P.C. AND E.C. <1 1 TO <1-1/2 EACH TRADE RESPONSIBLE FOR LOCATING THEIR RESPECTIVE SYSTEMS. TEMPORARY UTILITIES TEMPORARY HEAT G.C. SERVICE HOT WATER (WITH HEAT TRACE) 0.27 MAX - TEMPORARY ELECTRICAL SERVICE E.C. E.C. E.C. R(E)D WATER AND TOILET AND FACILITIES G.C. 0.27 MAX - 1" CONCRETE M/E EQUIPMENT PADS, HOUSEKEEPING PADS, CONCRETE SAWING, PATCHING, CORE DRILLING, AND REPAIR. G.C. EXIST. SANITARY SEWER ABOVE FLOOR 1" SERVICE HOT WATER (FIRST 8' OF NON -CIRCULATION EXCAVATION EXCAVATION, BACKFILL, AND CONCRETE OR ASPHALT PAVING FOR UTILITIES OR OTHER M/E EQUIPMENT. G.C. 0.5" 0.5" 0.5" HVAC ROOF TOP EQUIPMENT, FIELD BUILT ROOF CURBS/PLATFORMS, AND DUCT CURBS. FOR ALL ROOF CONSTRUCTION EXCEPT METAL ROOFS. STRUCTURAL FRAMING FOR SUPPORT. G.C. SAND/OIL INTERCEPTOR LINE ABOVE FLOOR S/0 G.C. ALSO TO PROVIDE FRAMING FOR PENETRATIONS. FIELD BUILT EQUIPMENT PLATFORMS AND DUCT CURBS, TOP MINIMUM 9" ABOVE FINISHED ROOF. G.C. ---------S/0(E)--- EXISTING SAND/OIL INTERCEPTOR LINE UNDER FLOOR G.C. TO CONSTRUCT PLATFORM/CURB FROM 2X10'S AS REQ'D AND CAP WITH 3/4" PLYWOOD AND 40# COATED FELT. FLASHING OVER THE TOP OF PLATFORMS AND DUCT CURBS. H.C. 250 4.5" H.C. TO PROVIDE 26 GA. G.S. METAL TOP EXTENDING 3' DOWN SIDES. ALL JOINTS SOLDERED WATERTIGHT. ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM G.C. -•-•-•-•-•-•- OD -•-•- 5" MECHANICAL SYSTEM PIPING 251-350 WAC ROOF TOP EQUIPMENT, FIELD BUILT ROOF CURBS/PLATFORMS, AND DUCT CURBS. METAL ROOFS ONLY. STRUCTURAL FRAMING FOR SUPPORT. G.C. 4.0" 4.5" G.C. ALSO TO PROVIDE FRAMING FOR PENETRATIONS. EQUIPMENT CURBS, PLATFORMS, AND DUCT CURBS. G.C. MECHANICAL SYSTEM PIPING 201-250 0.27-0.30 G.C. TO OBTAIN ROOF CURBS FROM BUILDING MANUFACTURER ON NEW CONSTRUCTION PROJECTS. FLASHING OVER THE TOP OF PLATFORMS AND DUCT CURBS. H.C. 2.5" 3" H.C. TO PROVIDE 26 GA. G.S. METAL TOP EXTENDING 3' DOWN SIDES. ALL JOINTS SOLDERED WATERTIGHT. ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM G.C. 0.25-0.29 125 1.5" MECH/ELEC EQUIPMENT AND FIXTURE MOUNTING STRUCTURAL FRAMING FOR SUPPORT. G.C. PVC COMBUSTION AIR 2.0" MECHANICAL SYSTEM PIPING 105-140 HANGERS, MOUNTING HARDWARE, ANCHORS, PIPING STANDS, AND EQUIPMENT LEGS. H.C. P.C. E.C. H.C. P.C. E.C. 1.0" EACH TRADE RESPONSIBLE FOR MOUNTING THEIR RESPECTIVE EQUIPMENT. ROOFING AND ROOF PENETRATIONS PIPE AND ROUND DUCT/VENT ROOFJACKS. H.C. P.C. E.C. H.C. P.C. E.C. 0.21-0.27 G.C. TO PROVIDE ROOFJACKS AND FLASHING ON METAL ROOF SYSTEMS. PITCH PANS FOR EQUIPMENT LEGS OR PIPE STANDS. H.C. P.C. E.C. H.C. P.C. E.C. 1.0" EACH TRADE RESPONSIBLE FOR PITCH PANS REQ'D FOR THEIR EQUIPMENT. DRAIN, OVERFLOW SCUPPERS, AND GUTTERS. G.C. 0.20-0.26 75 0.5" ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM G.C. 1.0" 1.5" PATCH/REPAIR PATCHING AND REPAIRING OF EXISTING CONSTRUCTION. G.C. 0.5" 0.5" 0.5" PAINTING EQUIPMENT, DUCTS, PIPES, LOUVERS, AND ETC. G.C. FOOTNOTES: NOT IN CAVITIES (A) FOR PIPING SMALLER THAN 11/2 INCH (38 MM) AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH (25 MM) SHALL ACCESS DOORS FOR M/E EQUIPMENT REQUIRING ACCESS. H.C. P.C. EC. G.C. EACH TRADE TO FURNISH ACCESS DOORS AS REQ'D FOR THEIR EQUIP. FIRE RATED CHASES FOR GREASE DUCTS, FLUES, DUCTS, AND ETC. G.C. 2. FACTORY -INSTALLED PIPING WITHIN ROOM FAN -COILS AND UNIT VENTILATORS TESTED AND RATED ACCORDING TO AHRI 440 (EXCEPT THAT THE SAMPLING AND VARIATION ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA PROVISIONS OF SECTION 6.5 SHALL NOT APPLY) AND 840, RESPECTIVELY. ELECTRICAL CONTROL TRANSFORMERS FOR HVAC EQUIPMENT H.C. E.C. E.C. 5. STRAINERS, CONTROL VALVES, AND BALANCING VALVES ASSOCIATED WITH PIPING 1 INCH (25 MM) OR LESS IN DIAMETER. HVAC CONTROL WIRING 48 VOLTS AND LESS. H.C. H.C. HVAC CONTROL WIRING GREATER THAN 48 VOLTS. E.C. E.C. INCLUDING HVAC EQUIP. INTERLOCK WIRING HIGH AND LOW VOLTAGE. E.C. WELL AS GROUP R-2, R-3 AND R-4 BUILDINGS THREE STORIES OR LESS IN HEIGHT E.C. ABOVE GRADE PLANE. CONDUIT FOR ALL WIRING. E.C. EC. DISCONNECT SWITCHES. E.C. E.C. E.C. MOTOR STARTERS TO INCLUDE THERMAL OVERLOADS. H.C. AND P.C. EC. E.C. EACH TRADE TO FURNISH STARTERS AS REQ'D FOR THEIR EQUIP. DUCT MOUNTED SMOKE DETECTORS INTERFACED WITH BUILDING FIRE ALARM SYSTEM. F.A.C. OR E.C. H.C. FAC. OR E.C. H.C. TO PROVIDE ACTUAL DUCT SIZE MEASUREMENTS. IN BUILDING W/O FIRE ALARM/DETECTION SYSTEM. H.C. H.C. E.C. INTERLOCKS W/HVAC SYSTEM FANS. E.C. ABBREVIATIONS: E.C.-ELECTRICAL CONTRACTOR, F.A.C.-FIRE ALARM CONTRACTOR, G.C.-GENERAL CONTRACTOR, H.C.-HVAC CONTRACTOR, M/E-MECHANICAL/ELECTRICAL, P.C.-PLUMBING CONTRACTOR COMMERCIAL PIPING INSULATION SCHEDULE 2018 IECC COLD WATER - - ------ CW UF- THICKNESS OF INSULATION (INCHES) (A) - CW(E) EXISTING COLD WATER INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE (INCHES) - - -HW SERVICE FLUID OPERATING TEMPERATURE RANGE - - -HW UF- HOT WATER, UNDER FLOOR - - HW(E) CONDUCTIVITY (B) * r MEAN RATING TEMPERATURE, <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 TEMPERED WATER, TEMP NOTED, BELOW FLOOR -<8 SERVICE HOT WATER (WITH HEAT TRACE) 0.27 MAX - 1" 1" 1' 1" R(E)D 1" SERVICE HOT WATER (RE-CIRULATING) 0.27 MAX - 1" 1" 1' 1" EXIST. SANITARY SEWER ABOVE FLOOR 1" SERVICE HOT WATER (FIRST 8' OF NON -CIRCULATION 0.27 MAX - 0.5" 0.5" 0.5" 0.5" ---------GI(E)---- 0.5" SYSTEMS AT EQUIPMENT WITHOUT HEAT TRAPS) SAND/OIL INTERCEPTOR LINE ABOVE FLOOR S/0 SAND/OIL INTERCEPTOR LINE UNDER FLOOR ---------S/0(E)--- EXISTING SAND/OIL INTERCEPTOR LINE ABOVE FLOOR ---------S/0(E)--- EXISTING SAND/OIL INTERCEPTOR LINE UNDER FLOOR -•-•-•-•-•-•- RD -•-•- MECHANICAL SYSTEM PIPING >3517F 0.32-0.34 250 4.5" 5" 5" 5" -•-•-•-•-•-•- OD -•-•- 5" MECHANICAL SYSTEM PIPING 251-350 0.29-0.32 200 3" 4.0" 4.5" 4.5" SEWER VENT ABOVE FLOOR 4.5" MECHANICAL SYSTEM PIPING 201-250 0.27-0.30 150 2.5" 2.5" 2.5" 3" ®D UF® 3 - MECHANICAL SYSTEM PIPING 141-200 0.25-0.29 125 1.5" 1.5" 2.0' 2.0" PVC COMBUSTION AIR 2.0" MECHANICAL SYSTEM PIPING 105-140 0.21-0.27 100 1.0" 1.0" 1.5' 1.5' G(E) 1.5' MECHANICAL SYSTEM PIPING 40-60 0.21-0.27 75 0.5" 0.5" 1.0' 1.0" OXYGEN 1.0" MECHANICAL SYSTEM PIPING <40 0.20-0.26 75 0.5" 1.0" 1.0' 1.0" 1.5" ROOF DRAIN (HORIZONTAL OR UNHEATED AREAS) (C) 0.27 - 0.5" 0.5" 0.5" 0.5 0.5" FOOTNOTES: NOT IN CAVITIES (A) FOR PIPING SMALLER THAN 11/2 INCH (38 MM) AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH (25 MM) SHALL BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE B) BUT NOT TO A THICKNESS LESS THAN 1 INCH (25 MM). SOLID WALL (B) FOR INSULATION OUTSIDE THE STATED CONDUCTIVITY RANGE, THE MINIMUM THICKNESS (T) SHALL BE DETERMINED USING THE EQUATION IN THE 2015 IECC SECTION C403.2.1. (C) IECC DOES NOT REQUIRE ROOF DRAINS TO BE INSULATED. INSULATION IS REQUIRED AS GOOD DESIGN PRACTICE. EXCEPTIONS: AIR PLENUM 1. FACTORY -INSTALLED PIPING WITHIN HVAC EQUIPMENT TESTED AND RATED IN ACCORDANCE WITH A TEST PROCEDURE REFERENCED BY THIS CODE. F493, SOLVENT CEMENT MUST BE YELLOW, LIMITED TO 1/2" THROUGH 2" PIPE SIZES, 2. FACTORY -INSTALLED PIPING WITHIN ROOM FAN -COILS AND UNIT VENTILATORS TESTED AND RATED ACCORDING TO AHRI 440 (EXCEPT THAT THE SAMPLING AND VARIATION ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA PROVISIONS OF SECTION 6.5 SHALL NOT APPLY) AND 840, RESPECTIVELY. 3. PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURE RANGE BETWEEN 60•F (15'C) AND 105'F (41'C). 4. PIPING THAT CONVEYS FLUIDS THAT HAVE NOT BEEN HEATED OR COOLED THROUGH THE USE OF FOSSIL FUELS OR ELECTRIC POWER. 5. STRAINERS, CONTROL VALVES, AND BALANCING VALVES ASSOCIATED WITH PIPING 1 INCH (25 MM) OR LESS IN DIAMETER. 6. DIRECT BURIED PIPING THAT CONVEYS FLUIDS AT OR BELOW 60-F (15'C). GENERAL NOTES: - 2018 IECC SECTIONS C403.2.10, C403.2.1 AND C404.4. - INSULATION EXPOSED TO WEATHER SHALL BE JACKETED WITH .016" THICK - 2018 IECC COMMERCIAL SECTION APPLIES TO ALL BUILDINGS THAT ARE NOT CONSIDERED ALUMINUM. "RESIDENTIAL BUILDINGS". "RESIDENTIAL BUILDINGS" ARE DETACHED ONE- AND - INSULATION ON COLD PIPES SHALL HAVE A VAPOR BARRIER APPLIED INCLUDING TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) AS ALL JOINTS AND TERMINATIONS. WELL AS GROUP R-2, R-3 AND R-4 BUILDINGS THREE STORIES OR LESS IN HEIGHT ABOVE GRADE PLANE. I GENERAL PLUMBING PROVISIONS I 1. WORK INCLUDED. PROVIDE COMPLETE AND OPERATING PLUMBING SYSTEMS. THE WORK ALSO INCLUDES THE COMPLETION OF DETAILS NOT MENTIONED OR SHOWN WHICH ARE NECESSARY FOR THE SUCCESSFUL OPERATION OF ALL SYSTEMS. SEE 'HVAC, PLUMBING, ELECTRICAL AND GENERAL CONTRACTOR COORDINATION SCHEDULE' FOR DIVISION OF WORK. 2. PLUMBING DRAWINGS. PLUMBING DRAWINGS ARE DIAGRAMMATIC AND ARE NOT TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK. VERIFY SPACE REQUIREMENTS, COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE SPACE PROVIDED WITHOUT VIOLATION OF APPLICABLE CODES, STANDARDS, SPECIFICATION REQUIREMENTS, OR EXTRA CHARGES TO THE OWNER. 3. VERIFICATION OF FIELD CONDITIONS. BEFORE UNDERTAKING EACH PART OF THE WORK, CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH FIELD MEASUREMENTS. PROMPTLY REPORT IN WRITING TO THE MECHANICAL ENGINEER ANY CONFLICT, ERROR OR DISCREPANCY. 4. EQUIPMENT AND FIXTURES FURNISHED BY OTHERS. COORDINATE EXACT REQUIREMENTS OF EQUIPMENT AND FIXTURES FURNISHED BY OTHERS BEFORE PERFORMING ANY WORK. 5. PERMITS. APPLY FOR AND PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS DIVISION OF WORK. 6. CODES. COMPLY WITH ALL APPLICABLE CODES AND UTILITY COMPANY REGULATIONS. IN CASE OF CONFLICT WITH THE CONTRACT DOCUMENTS THE MOST STRINGENT SHALL GOVERN. 7. ACCESS DOORS. FURNISH ACCESS DOORS TO PROVIDE ACCESS TO ALL FIRE DAMPERS, VALVES, BALANCING DAMPERS, AND OTHER EQUIPMENT REQUIRING ACCESS. ACCESS DOORS FOR INSTALLATION IN FIRE RATED CONSTRUCTION SHALL HAVE APPROPRIATE FIRE RATING. 8. SPECIFIED MANUFACTURERS AND ALTERNATES. AN ACCEPTABLE MANUFACTURER'S NAME AND MODEL NUMBER OF A PRODUCT MAY BE GIVEN FOR AN EXAMPLE. THIS IS THE EQUIPMENT CONTEMPLATED DURING THE DESIGN PROCESS AND FORMS THE BASIS OF A STANDARD OF QUALITY. VERIFY THE MODEL NUMBER IS STILL ACCURATE AND MEETS ALL THE REQUIREMENTS AS SHOWN ON THE DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN THE REQUIREMENTS OF THE DRAWINGS AND THE MODEL NUMBER, THE REQUIREMENTS OF THE DRAWINGS SHALL GOVERN. APPROVED EQUALS SHALL BE ALLOWED UNLESS OTHERWISE NOTED. 9. SUBMITTALS. A. REQUIRED SUBMITTALS. SUBMIT ELECTRONIC COPIES OF THE FOLLOWING INFORMATION FOR APPROVAL ORDER NO MATERIALS OR BEGIN NO WORK UNTIL ALL SUBMITTALS ARE RETURNED APPROVED. 1.) ALL SCHEDULED FIXTURES AND EQUIPMENT. 2.) CONTROLS AND CONTROL DIAGRAMS. 3.) SHOP DRAWINGS REQUIRED TO BE SUBMITTED FOR APPROVAL 4.) OTHER INFORMATION SPECIFICALLY REQUIRED TO BE SUBMITTED FOR APPROVAL. B. REVIEW TIME. ALLOW 5 WORKING DAYS FOR REVIEW OF SUBMITTALS. C. RESUBMISSION. MAKE ALL REVISIONS REQUIRED AND RESUBMIT AS REQUIRED FOR INITIAL SUBMITTAL 10. WARRANTIES. GUARANTEE ALL WORKMANSHIP, MATERIAL AND EQUIPMENT AND REPLACE ANY FOUND DEFECTIVE WORK WITHOUT COST TO THE OWNER, FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. 11. OPERATION AND MAINTENANCE MANUALS. SUBMIT 3 COPIES BOUND IN 8-1/2" X 11" THREE RING, LOOSE LEAF BINDERS. 12. MATERIALS. ALL MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE SPECIFIED. A ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA REDUCTION OF LEAD IN DRINKING WATER ACT OF 2011. 13. INSTALLATION OF EQUIPMENT. A GENERAL B. SPACE PREFERENCE. WHERE CONFLICTS OCCUR THE FOLLOWING PREFERENCE SCHEDULE SHALL BE USED: 1. RECESSED ELECTRICAL LIGHT FIXTURES. 2. DUCTWORK. 3. SPRINKLER PIPING. 4. SOIL, WASTE, VENT AND STORM PIPING. 5. LIQUID HEAT TRANSFER AND REFRIGERANT PIPING. 6. DOMESTIC WATER PIPING. 7. ELECTRICAL CONDUITS. ITEMS /2 SWILL NOT HAVE PREFERENCE OVER ITEM #4 BELOW PLUMBING FIXTURES, OR OVER ITEM #7 ABOVE OR BELOW ELECTRIC SWITCH GEAR AND PANELS. NO PIPING CONVEYING FLUIDS SHALL BE INSTALLED DIRECTLY OVER ELECTRICAL EQUIPMENT. 14. PIPE INSULATION. SEE EITHER THE COMMERCIAL OR RESIDENTIAL PIPE INSULATION SCHEDULE FOR WHERE PIPE INSULATION IS REQUIRED. OTHER INSULATION MAY BE REQUIRED IF R IS SPECIFICALLY CALLED OUT ON THE PLANS. I PLUMBING LEGEND I SYMBOL DESCRIPTION - ------- CW COLD WATER - - ------ CW UF- COLD WATER, UNDER FLOOR - CW(E) EXISTING COLD WATER - CW(E) OF EXISTING COLD WATER, UNDER FLOOR - - -HW HOT WATER - - -HW UF- HOT WATER, UNDER FLOOR - - HW(E) EXISTING HOT WATER - - HW(E) OF EXISTING HOT WATER, UNDER FLOOR - - - 105'- TEMPERED WATER, TEMPERATURE NOTED (FAHRENHEIT) - - -105' UF- TEMPERED WATER, TEMP NOTED, BELOW FLOOR - - 105'(E) EXISTING TEMPERED WATER, TEMP NOTED (FAHRENHEIT) - - 105'(E) OF EXISTING TEMPERED WATER, TEMP NOTED, UNDER FLOOR -•-R In HOT WATER CIRCULATION RETURN WITH FLOW ARROW -•- UFS HOT WATER CIRCULATION RETURN, UNDER FLOOR R(E)D EXISTING HOT WATER CIRC. RETURN WITH FLOW ARROW - - - -00--R(E) OF EXISTING HOT WATER CIRC. RETURN, UNDER FLOOR SS- SANITARY SEWER ABOVE FLOOR -SS- SANITARY SEWER UNDER FLOOR SS(E) EXIST. SANITARY SEWER ABOVE FLOOR - -SS(E) EXIST. SANITARY SEWER UNDER FLOOR ----------GI---- GREASE INTERCEPTOR LINE ABOVE FLOOR GI GREASE INTERCEPTOR UNE UNDER FLOOR - - - - - - - --GI(E)- - - - EXISTING GREASE INTERCEPTOR LINE ABOVE FLOOR ---------GI(E)---- EXISTING GREASE INTERCEPTOR UNE UNDER FLOOR ---------S/0---- SAND/OIL INTERCEPTOR LINE ABOVE FLOOR S/0 SAND/OIL INTERCEPTOR LINE UNDER FLOOR ---------S/0(E)--- EXISTING SAND/OIL INTERCEPTOR LINE ABOVE FLOOR ---------S/0(E)--- EXISTING SAND/OIL INTERCEPTOR LINE UNDER FLOOR -•-•-•-•-•-•- RD -•-•- ROOF DRAIN ABOVE FLOOR RD ROOF DRAIN UNDER FLOOR -- - - ---RD(E)-.- - EXISTING ROOF DRAIN ABOVE FLOOR ------.-RD(E)� EXISTING ROOF DRAIN UNDER FLOOR -•-•-•-•-•-•- OD -•-•- ROOF OVERFLOW DRAIN ABOVE FLOOR OD ROOF OVERFLOW DRAIN UNDER FLOOR -------OD(E)-.- - EXISTING ROOF OVERFLOW DRAIN ABOVE FLOOR .......... --OD(E)--- EXISTING ROOF OVERFLOW DRAIN UNDER FLOOR -V- - SEWER VENT ABOVE FLOOR - - - - -V UF-- SEWER VENT UNDER FLOOR V(E) EXISTING SEWER VENT ABOVE FLOOR V(E) UF- - EXISTING SEWER VENT UNDER FLOOR -••-••-••-••-••-D-••-••- EQUIPMENT DRAIN ABOVE FLOOR ®D UF® EQUIPMENT DRAIN BELOW FLOOR - - - - --D(E).. EXISTING EQUIP. DRAIN ABOVE FLOOR - - - - -D(E) UF- EXISTING EQUIP. DRAIN BELOW FLOOR - - -CV- - PVC COMBUSTION VENT --C/1 - PVC COMBUSTION AIR - -CV(E) EXISTING PVC COMBUSTION VENT - -CA(E) EXISTING PVC COMBUSTION AIR G NATURAL GAS ABOVE FLOOR G UF- NATURAL GAS UNDER FLOOR G(E) EXISTING NAT. GAS ABOVE FLOOR G(E) OF EXISTING NAT. GAS UNDER FLOOR A COMPRESSED AIR NO NITROUS OXIDE 0 OXYGEN VAC- VACUUM C ELBOW DOWN 0 ELBOW UP TEE DOWN TEE UP -ili- UNION HOSE BIBB -►� GATE VALVE, NORMALLY OPEN -D4- GATE VALVE, NORMALLY CLOSED BALL VALVE, NORMALLY OPEN BALL VALVE. NORMALLY CLOSED n SOLENOID VALVE NORMALLY OPEN ACCUSETTER VALVE FOR RECIRCULATING SYSTEMS Nc c 3 -WAY MOTORIZED VALVE No -- CENTRIFUGAL PUMP PIPE GAS COCK PROTECTION LOG LIGHTER VALVE ® AIR ADMITTANCE VALVE (STUDOR VENT) SCH. 40 BLACK GAS REGULATOR c LOCATION OF COLD WATER ROUGH -IN. • LOCATION OF HOT WATER ROUGH -IN. CONNECTION TO EXIST. WORK, SEE CONNECTION 1 NOTE #1 FOR EXPLANATION IF APPLICABLE XX- PLAN CODE FOR EQUIPMENT FURNISHED BY OTHERS. PLUMBER TO PROVIDE ROUGH -IN AND FINAL CONNECTION. REFER TO FIXTURES/EQUIPMENT FURNISHED BY OTHERS SCHEDULE COORDINATE WITH SUPPLIER TO DETERMINE EXACT REQUIREMENTS BEFORE PERFORMING ANY WORK. GAS PIPING SCHEDULE SERVICE PIPE FITTINGS PROTECTION COVER REMARKS WROUGHT COPPER SCH. 40 BLACK 150# MALLEABLE APPROVED PROTECTIVE COATING EITHER AT LEAST 12" OF FUEL GAS PIPING. BLACK IRON. IRON WELDED. FIELD OR FACTORY APPLIED. EARTH COVER. • NATURAL GAS) OUTSIDE BUILDING. TYPE "K" SOFT FLARED TYPE 0zr two Om DRAWN COPPER. O 0 O � C7 4_j COLD WATER AND TYPE "K" COPPER BURIED)* POLYETHYLENE POLYETHYLENE PIPE SHALL HAVE THE WORD "GAS" AT LEAST 18" OF 1/2"0 PIPE SHALL BE WITHIN BUILDING. (PE 2406) (PE 2406) MARKED ON IT AND A TRACER WIRE EARTH COVER. SDR 9. PIPE >1/2"0 WROUGHT COPPER ASTM D 2513 ASTM D 2513, ASTM SHALL BE ATTACHED TO PIPE.** SWEAT TYPE SHALL BE SDR 11. TYPE "M" COPPER D 2683, AND/OR COLD WATER AND ASTM D 3261 CROSS-LINKED POLYETHYLENE (PEX) DRY FIT INSTALL IN ACCORDANCE WITH FUEL GAS PIPING. SCH. 40 BLACK 150# MALLEABLE G.C. TO PAINT PIPING EXPOSED TO NOT APPLICABLE PLASTIC TUBING NATURAL GAS) BLACK IRON. IRON THREADED THE WEATHER. ABOVE GROUND) POLYVINYL CHLORIDE OR WELDED. (CPVC) PLASTIC * - GAS PIPING SHALL NOT BE INSTALLED UNDER ANY BLDG. OR SLAB AND SHALL ENTER BUILDING ABOVE GRADE. RISERS TO ABOVE GRADE SHALL BE METALLIC AND COATED WITH APPROVED COATING TO A POINT AT LEAST 6" ABOVE FINISHED GRADE. ** - TRACER WIRE SHALL BE #18 AWG COPPER (OR OTHER APPROVED MATERIALS) AND SHALL RUN THE FULL LENGTH OF BELOW GRADE PIPE AND TERMINATE ABOVE GRADE AT ONE END. I ABBREVIATION LEGEND I A - COMPRESSED AIR AFC - ABOVE FINISH CEILING AFF - ABOVE FINISH FLOOR BFC - BELOW FINISH CEILING BFF - BELOW FINISH FLOOR Co - CLEANOUT CW - COLD WATER D - EQUIPMENT DRAIN DN - DOWN EA - EACH E.C. - ELECTRICAL CONTRACTOR FOO - FLOOR CLEANOUT G - GAS (NATURAL) G.C. - GENERAL CONTRACTOR GI - GREASE INTERCEPTOR UNE GM - GAS METER GW - GRAY WATER H.C. - HVAC CONTRACTOR HW - HOT WATER ID - INSIDE DIMENSIONS RY - INDIRECT WASTE MAX - MAXIMUM MIN - MINIMUM MPG - MEDIUM PRESSURE GAS NO - NITROUS OXIDE NO. - NUMBER 0 - OXYGEN OD - OVERFLOW DRAIN P.C. - PLUMBING CONTRACTOR PD - PUMPED DISCHARGE PRESS. - PRESSURE R - HOT WATER RECIRCULATION LINE RD - ROOF DRAIN REQ'D - REQUIRED S/0 - SAND/OIL INTERCEPTOR LINE SS - SANITARY SOIL ST - STORM SEWER TDH - TOTAL DYNAMIC HEAD PRESSURE TYP. - TYPICAL UG - UNDERGROUND OF - UNDER FLOOR U.O.N. - UNLESS OTHERWISE NOTED V - VENT VAC - VACUUM VTR - VENT THRU ROOF WCO - WALL CLEANOUT WM - WATER METER WT - WEIGHT I UNITS LEGEND I LF - LINEAR FEET SF - SQUARE FEET CF - CUBIC FEET CFM - CUBIC FEET PER MINUTE GPM - GALLONS PER MINUTE GPH - GALLONS PER HOUR GAL - GALLONS FPM - FEET PER MINUTE BTU/HR - BRITISH THERMAL UNITS PER HOUR MBH - BTU/HR X 1000 IN WG - INCHES OF WATER GAUGE PRESSURE FT WG - FEET OF WATER GAUGE PRESSURE PSI - POUNDS PER SQUARE INCH LB - POUNDS V - VOLTS A - AMPS W - WATTS KW - KILOWATTS HP - HORSE POWER HZ - HERTZ RPM - REVOLUTIONS PER MINUTE PLUMBING PIPING SCHEDULE SERVICE PIPE FITTINGS REMARKS TYPE "K" HARD WROUGHT COPPER CU -PH SOLDER COLD WATER AND DRAWN COPPER. SWEAT TYPE HOT WATER BURIED O < o o Lu • U OUTSIDE BUILDING. TYPE "K" SOFT FLARED TYPE 0zr two Om DRAWN COPPER. O 0 O � C7 4_j COLD WATER AND TYPE "K" COPPER CU -PH SOLDER HOT WATER BURIED OR WROUGHT COPPER OR WITHIN BUILDING. TYPE "L" COPPER SWEAT TYPE <.2% LEAD SOLDER TYPE "L" COPPER WROUGHT COPPER <.2% LEAD SOLDER OR SWEAT TYPE TYPE "M" COPPER COLD WATER AND HOT WATER ABOVE CROSS-LINKED POLYETHYLENE (PEX) DRY FIT INSTALL IN ACCORDANCE WITH GROUND. PLASTIC TUBING MFG. INSTRUCTIONS SCH 80 CHLORINATED GLUE JOINTS POLYVINYL CHLORIDE SOLVENT WELD) ( (CPVC) PLASTIC CAST IRON CAST IRON STAINLESS STEEL SANITARY SOIL HUBLESS HUBLESS HARDWARE BURIED. SCH 40 PVC DWV SCH 40 PVC DWV SOLID WALL SOLID WALL CAST IRON CAST IRON STAINLESS STEEL HUBLESS HUBLESS HARDWARE SCH. 40 GALVANIZED. SCH. 40 GALVANIZED. 2" AND SMALLER SANITARY SOIL AND VENT ABOVE GROUND. ROOF DRAINS. DWV COPPER. DWV COPPER SWEAT CONNECTIONS. SCH 40 PVC DWV SCH 40 PVC DWV NOT IN CAVITIES SOLID WALL SOLID WALL USED AS A RETURN AIR PLENUM NOTES: SOLVENT CEMENT MUST BE THIRD -PARTY CERTIFIED AS CONFORMING TO ASTM F493, SOLVENT CEMENT MUST BE YELLOW, LIMITED TO 1/2" THROUGH 2" PIPE SIZES, AND PIPE FITTINGS MUST MEET ASTM D2846. ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA REDUCTION OF LEAD IN DRINKING WATER ACT OF 2011. DESIGN SUMMARY FOR PLAN REVIEWER I GOVERNING CODES: 2018 IPC, 2018 IFGC, 2012 IECC COMCHECK: ENVELOPE COMCHECK - YES - ON PLANS/NOT REQUIRED/PROVIDED BY ARCH. EQUIPMENT COMCHECK - YES - ON PLANS/NOT REQUIRED GIS APPLIANCE LABEL INFORMATION EXAMPLE: WH -1 40 MBH (32 MBH) 38 CFH WH -1 HAS A SEA LEVEL INPUT OF 40 MBH. WH -1 HAS AN ALTITUDE INPUT OF 32 MBH. WH -1 HAS AN ALTITUDE FLOWRATE OF 38 CFH. 2"G (100') 38 CFH GAS PIPE SHOWN HAS AN INSIDE DIAMETER OF 2" & SUPPLIES A FLOWRATE OF 38 CU.FT./HR. THE LENGTH INDICATES THE MAX DISTANCE (FROM APPLIANCE TO METER) THAT THIS PIPE SUPPLIES. Oe r]r]7(1C T co co I- I - z z Lu Lu O O 0 0 0 N I PLAN DATES I m V Z Pbbo�l Fs,�. �"5 00 1�x w dc Ci W � 0�/� VJ M M O 00 W O �U Q Lu 00 Q Lo LU N 19-016 SHEET NO. P3-000 a O < o o Lu • U p 0 0 W 0zr two Om H� O 0 O � C7 4_j m V Z Pbbo�l Fs,�. �"5 00 1�x w dc Ci W � 0�/� VJ M M O 00 W O �U Q Lu 00 Q Lo LU N 19-016 SHEET NO. P3-000 HVAC, PLUMBING, ELECTRICAL, AND GENERAL CONTRACTOR COORDINATION SCHEDULE CATEGORY DESCRIPTION OF WORK FURNISHED BY MOUNTED BY WIRED BY CONDUCTORS IN 3" CONDUIT. LOCATING EXISTING UTILITIES EXTERIOR. G.C. SINGLE PHASE TRANSFORMERS INTERIOR. P.C./E.C. m'i°.ewn. PAD UTILITY TRANSFORMER EACH TRADE RESPONSIBLE FOR LOCATING THEIR RESPECTIVE SYSTEMS. TEMPORARY UTILITIES TEMPORARY HEAT. G.C. ^ DELTA -DELTA 30 ,a TEMPORARY ELECTRICAL SERVICE. E.C. E.C. E.C. CABINET WATER AND TOILET AND FACILITIES. G.C. UNDERCABINET LINEAR FIXTURE. BUSSED WEATHERHEAD I °Fl CONCRETE M/E EQUIPMENT PADS, HOUSEKEEPING PADS, CONCRETE SAWING, PATCHING, CORE DRILLING, AND REPAIR. G.C. RECESSED TROFFERS. WITH FAULTGROUND CURR NT STRIP/WRAP FIXTURE. EXCAVATION EXCAVATION, BACKFILL, AND CONCRETE OR ASPHAULT PAVING FOR UTILITIES OR OTHER M/E EQUIPMENT. G.C. SURFACE/SUSPENDED FIXTURE. CURRENT An ROOF TOP, FIELD BUILT EQUIPMENT PLATFORMS AND DUCT CURBS. STRUCTURAL FRAMING FOR SUPPORT. G.C. BOLLARD FIXTURE. WITH ADJUSTABLE FIXTURE. FIELD BUILT EQUIPMENT PLATFORMS AND DUCT CURBS, TOP MINIMUM 9" ABOVE FINISHED ROOF. G.C. TRIP SETTINGS O G.C. TO CONSTRUCT PLATFORM/CURB FROM 2X10'S AS REQ'D AND CAP WITH 3/4" PLYWOOD AND 40# COATED FELT. FLASHING OVER THE TOP OF PLATFORMS AND CURBS.H C SINGLE FACE WITH INDICATION ARROW H.C. TO PROVIDE 26 GA. G.S. METAL TOP EXTENDING 3" DOWN SIDES. ALL JOINTS SOLDERED WATERTIGHT. ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM. G.C. FUSED SWITCH ® Q DIESEL/NATURAL GAS GENERATOR EQUIPMENT AND FIXTURE MOUNTING STRUCTURAL FRAMING FOR SUPPORT. G.C. HANGERS, MOUNTING HARDWARE, ANCHORS, PIPING STANDS, AND EQUIPMENT LEGS.THEIR H.C./P.C./E.C.EACH flY6 A NEW/EXISTING TRADE RESPONSIBLE FOR MOUNTING RESPECTIVE EQUIPMENT. ROOFING AND ROOFING PENETRATIONS PIPE AND ROUND DUCT/VENT ROOFJACKS. H.C./P.C./E.C. EACH TRADE RESPONSIBLE FOR ROOFJACKS REQ'D FOR THEIR EQUIPMENT. PITCH PANS FOR EQUIPMENT LEGS OR PIPE STANDS. H.C./P.C./E.C. vwn A EACH TRADE RESPONSIBLE FOR PITCH PANS REQ'D FOR THEIR EQUIPMENT. DRAIN, OVERFLOW SCUPPERS, AND GUTTERS. G.C. WITH MAIN ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM. G.C. SYSTEM CIRCUIT BREAKER IW6A PAINTING EQUIPMENT, DUCTS, PIPES, LOUVERS, AND ETC. G.C. BOARD WITH MAIN WITH MAIN AND ACCESS DOORS FOR M/E EQUIPMENT REQUIRING ACCESS. H.C./P.C./E.C. G.C. EACH TRADE TO FURNISH ACCESS DOORS AS REQ'D FOR THEIR EQUIP. FIRE RATED CHASES FOR GREASE DUCTS, FLUES, DUCTS, AND ETC. G.C. I A ELECTRICAL CONTROL TRANSFORMERS FOR HVAC EQUIPMENT. H.C. E.C. E.C. HVAC CONTROL WIRING 48 VOLTS AND LESS. H.C. H.C. WITH FEEDTHRU HVAC CONTROL WIRING GREATER THAN 48 VOLTS. E.C. E.C. PIPE STEEL HVAC EQUIP. INTERLOCK WIRING HIGH AND LOW VOLTAGE E.C. E.C. CONDUIT FOR ALL WIRING. E.C. E.C. DISCONNECT SWITCHES. E.C. E.C. E.C. MOTOR STARTERS TO INCLUDE THERMAL OVERLOADS. H.C./P.C. E.C. E.C. EACH TRADE TO FURNISH STARTERS AS REQ'D FOR THEIR EQUIP. DUCT MOUNTED SMOKE DETECTORS INTERFACED WITH BUILDING FIRE ALARM SYSTEM. F.A.C./E.C. H.C. F.A.C./E.C. H.C. TO PROVIDE ACTUAL DUCT SIZE MEASUREMENTS. IN BUILDING W/O FIRE ALARM/DETECTION SYSTEM. H.C. H.C. E.C. INTERLOCKS W/HVAC SYSTEM FANS. E.C. ABBREVIATIONS: E.C.-ELECTRICAL CONTRACTOR, F.A.C.-FIRE ALARM CONTRACTOR, G.C.-GENERAL CONTRACTOR, H.C.-HVAC CONTRACTOR, P.C.-PLUMBING CONTRACTOR GENERAL ELECTRICAL PROVISIONS ONE LINE DIAGRAM LEGEND 2(4-250 MCM XHHW AL. - (2) PARALLEL RUNS CONSISTING #3 CU GND)3" C. OF (4) 250 MCM XHHW ALUMINUM NUMERICAL ONLY = CIRCUIT CONDUCTORS IN 3" CONDUIT. d* OVERHEAD UTILITY NL = NIGHT LIGHT (24 HOUR) SINGLE PHASE TRANSFORMERS LINE/LOW VOLTAGE SWITCH TRANSFORMER m'i°.ewn. PAD UTILITY TRANSFORMER DIMMER SWITCH DELTA -WYE 30 TRANSFORMER RECESSED CAN FIXTURE. SECONDARY ^ DELTA -DELTA 30 ,a CONNECTION WALL MOUNTED/VANITY FIXTURE. TRANSFORMER CABINET PENDANT FIXTURE. >=� UNDERCABINET LINEAR FIXTURE. BUSSED WEATHERHEAD I °Fl FUSED SWITCH �7 �✓ WEATHERHEAD(S) RECESSED TROFFERS. WITH FAULTGROUND CURR NT STRIP/WRAP FIXTURE. 10/30 RECESSED LINEAR FIXTURE. INTERRUPTER SURFACE/SUSPENDED FIXTURE. CURRENT An CIRCUIT BREAKER FLOOD LIGHT/ACCENT FIXTURE. TRANSFORMER BOLLARD FIXTURE. WITH ADJUSTABLE FIXTURE. WITH METER POLE FIXTURE. TRIP SETTINGS O METER �. AUTOMATIC TRANSFER SWITCH SINGLE FACE WITH INDICATION ARROW DUAL FACES EXIT SIGN (ATS) COMBO EXIT SIGN AND FROG EYES. FUSED SWITCH ® Q DIESEL/NATURAL GAS GENERATOR REMOTE LANDING FIXTURE. CIRCUIT BREAKER GROUND flY6 A NEW/EXISTING X 1 FAULT POINT ❑ PANELBOARD (MAIN LUG ONLY) vwn A NEW/EXISTING PANELBOARD WITH MAIN GROUNDING SYSTEM CIRCUIT BREAKER IW6A NEW/EXISTING BOARD WITH MAIN WITH MAIN AND UP SUBFEED CIRCUIT BREAKERS I A (2) 42 SPACE PANELBOARDS [ail WITH FEEDTHRU WATER BLDG LIFER DRIVEN LUGS KIT PIPE STEEL ROD 1. ELECTRICAL DRAWINGS ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND ARE NOT TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK. VERIFY SPACE REQUIREMENTS, COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE SPACE PROVIDED WITHOUT VIOLATION OF APPLICABLE CODES, STANDARDS, SPECIFICATION REQUIREMENTS, OR EXTRA CHARGES TO THE OWNER. BELFAY ENGINEERING WILL OCCASIONALLY PROVIDE PERFORMANCE SPECIFICATIONS FOR CERTAIN SUB—SYSTEMS OF THE DESIGN. ESPECIALLY SYSTEMS THAT RELY ON PROPRIETARY PARTS. IN SUCH CASES, IT IS TO BE UNDERSTOOD THAT BELFAY ENGINEERING IS RESPONSIBLE FOR A THOROUGH AND COHESIVE PERFORMANCE SPEC AND REVIEW OF SHOP DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING SHOP DRAWINGS AND INSTALLING A WORKING SYSTEM CONSISTENT WITH THE PERFORMANCE SPEC. 2. VERIFICATION OF FIELD CONDITIONS — BEFORE UNDERTAKING EACH PART OF THE WORK, CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH FIELD MEASUREMENTS. PROMPTLY REPORT IN WRITING TO THE ELECTRICAL ENGINEER ANY CONFLICT, ERROR OR DISCREPANCY. 3. EQUIPMENT FURNISHED BY OTHERS — COORDINATE EXACT ELECTRICAL REQUIREMENTS (VOLTAGE, PHASE, AMPS, AND ETC.) OF EQUIPMENT FURNISHED BY OTHERS BEFORE PERFORMING WORK. 4. PERMITS — APPLY FOR AND PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS DIVISION OF WORK. 5. CODES — COMPLY WITH ALL APPLICABLE CODES AND UTILITY COMPANY REGULATIONS. IN CASE OF CONFLICT WITH THE CONTRACT DOCUMENTS THE MOST STRINGENT SHALL GOVERN. 6. ACCESS DOORS — FURNISH ACCESS DOORS TO PROVIDE ACCESS TO ALL J—BOXES, PULL BOXES, AND OTHER EQUIPMENT AS REQUIRED. ACCESS DOORS FOR INSTALLATION IN FIRE RATED CONSTRUCTION SHALL HAVE APPROPRIATE FIRE RATING. 7. ADDING LOADS — BEFORE ADDING ANY LOAD NOT SHOWN ON THE PLANS, TO THE ELECTRICAL SYSTEM, SUBMIT REQUEST IN WRITING TO THE ELECTRICAL ENGINEER FOR APPROVAL. 8. SPECIFIED MANUFACTURERS AN ACCEPTABLE MANUFACTURER'S NAME AND MODEL NUMBER OF A PRODUCT MAY BE GIVEN FOR AN EXAMPLE. THIS IS THE EQUIPMENT CONTEMPLATED DURING THE DESIGN PROCESS AND FORMS THE BASIS OF A STANDARD OF QUALITY. VERIFY THE MODEL NUMBER IS STILL ACCURATE AND MEETS ALL THE REQUIREMENTS AS SHOWN ON THE DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN THE REQUIREMENTS OF THE DRAWINGS AND THE MODEL NUMBER, THE REQUIREMENTS OF THE DRAWINGS SHALL GOVERN. APPROVED EQUALS SHALL BE ALLOWED UNLESS OTHERWISE NOTED. 9. SUBMITTALS A. REQUIRED SUBMITTALS — SUBMIT ELECTRONIC COPIES OF THE FOLLOWING INFORMATION FOR APPROVAL 1.) SERVICE EQUIPMENT, PANELBOARDS, LOAD CENTERS, SWITCHES, FUSES, AND CIRCUIT BREAKERS. 2.) LIGHTING FIXTURES. 3.) WIRING DEVICES AND DEVICE PLATES. B. REVIEW TIME — ALLOW 5 WORKING DAYS FOR REVIEW OF SUBMITTALS. ORDER NO MATERIALS OR BEGIN NO WORK UNTIL ALL SUBMITTALS ARE RETURNED APPROVED. C. RESUBMISSION — MAKE ALL REVISIONS REQUIRED AND RESUBMIT AS REQUIRED FOR INITIAL SUBMITTAL 10. MISCELLANEOUS MATERIALS — THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS HARDWARE AND MATERIAL NOT SPECIFIED BUT NECESSARY TO PROVIDE A COMPLETE AND WORKING ELECTRICAL SYSTEM. THIS HARDWARE SHALL INCLUDE, BUT NOT BE LIMITED TO, ALL MISCELLANEOUS CONDUIT FITTINGS AND MOUNTING HARDWARE, LIGHT FIXTURE MOUNTING HARDWARE, BRACKETS, CONNECTORS, CORDS AND PLUGS. 11. WARRANTIES — GUARANTEE ALL WORKMANSHIP, MATERIAL AND EQUIPMENT AND REPLACE ANY FOUND DEFECTIVE WORK WITHOUT COST TO THE OWNER, FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. POWER PLAN LEGEND _�A (1) 1 -POLE HOME RUN; PANEL A, CIRCUIT #2. 2,4A (1) 2 -POLE HOME RUN; PANEL A, CIRCUIT #2,4. 1,3_5 _ A (3) 1 -POLE HOME RUNS; PANEL A. CKT #1,3,5. — — — CONDUIT CONCEALED IN WALL OR CEILING. — — — PVC CONDUIT UNDERGROUND USE. —USE— USE CABLE; SUITABLE FOR UNDERGROUND USE. CAPPED CONDUIT. OJ JUNCTION -BOX. ®v WALL TELEPHONE/DATA/TV OUTLET, 18" AFF UNLESS OTHERWISE NOTED. 3/4" CONDUIT STUBBED UP WALL TERMINATING ABOVE CLG. 0 COMPUTER DATA OUTLET. 3/4" CONDUIT STUBBED UP WALL TERMINATING ABOVE CLG. AC DUPLEX RECEPTACLE, 18" AFF UNLESS OTHERWISE NOTED; CIRCUIT #5. WP o5 GF] = GROUNDABOVE/BELOW TB COUNTER INTERRUPTER IG WP = WEATHERPROOF USB IG = ISOLATED GROUND USB = USB PORT(S) 0 DOUBLE DUPLEX RECEPTACLE, 18" AFF. 0a SWITCHED RECEPTACLE; SWITCH LEG = a. ® CEILING RECEPTACLE. ® ® FLOOR DUPLEX/D. DUPLEX RECEPTACLE. ® ® FLOOR COMBO DUPLEX/D. DUPLEX RECEPTACLE AND TELE./DATA/TV. SEE NOTE ABOVE. ® SPECIAL RECEPTACLE, REFER TO PANEL SCHEDULE FOR DETAILS. MULTI -OUTLET ASSEMBLY OR PLUGMOLD. SENSORS: OS = OCCUPANCY SENSOR (DUAL TECHNOLOGY) ®®® VS = VACANCY SENSOR (DUAL TECHNOLOGY) PE ®OO ® DH = DAYYLIGHTLTAIC HARVESTINGRSENSOR OssmoeE S = SMOKE DETECTOR CO = CARBON MONOXIDE S/STROBE = SMOKE WITH STROBE ELECTRONIC HORN AND STROBE. TELEPHONE BACKBOARD. (TBB) NON—FUSED SWITCH; FUSED SWITCH; COMBO MOTOR STARTER; MAGNETIC MOTOR STARTER. G gg� NEW/EXISTING PANELBOARD. SCSB = STRUCTURED CABLE SERVICE BOX; sccsssB PROVIDE (1)120V RECEPTACLE IN SCSB. ® PLUG FUSE SWITCH, 120V 15/20A. AlCy MOTOR EQUIPMENT. EF -1 EQUIPMENT BY OTHERS; "EF -1" = PLAN CODE. TC TIME—CLOCK, 7—DAY, ASTRONOMICAL TIME—KEEPING WITH BATTERY BACK—UP. cB CARD—READER, +48" AFF UNLESS OTHERWISE NOTED. 3/4" CONDUIT STUBBED UP WALL TERMINATING ABOVE CLG. ELECTRICAL MATERIALS AND METHODS LIGHTING PLAN LEGEND Al c ALPHANUMERIC = PLAN CODE �ZZ. Q� v 01 ro LOWERCASE LETTERS = SWITCH LEG . 2 NUMERICAL ONLY = CIRCUIT WM HATCH FILL = EGRESS Z a) c � NL = NIGHT LIGHT (24 HOUR) a a LINE/LOW VOLTAGE SWITCH 3 -WAY SWITCH DIMMER SWITCH RECESSED CAN FIXTURE. RECESSED DIRECTIONAL WALL FIXTURE. J® { } CEILING MOUNTED FIXTURE. y WALL MOUNTED/VANITY FIXTURE. PENDANT FIXTURE. >=� UNDERCABINET LINEAR FIXTURE. � TAPE/ROPE/FESTOON FIXTURE. Q,,Q X CEILING FAN WITH LIGHT KIT. El E;:]2'X2'/2'X4' RECESSED TROFFERS. I-- STRIP/WRAP FIXTURE. m RECESSED LINEAR FIXTURE. 0 SURFACE/SUSPENDED FIXTURE. TRACK FIXTURE. OQ FLOOD LIGHT/ACCENT FIXTURE. 0 BOLLARD FIXTURE. OPEDESTRIAN FIXTURE. 0-0 POLE FIXTURE. E STEP FIXTURE. Q i T Ip EXIT SIGNS: SINGLE FACE EXIT SIGN SINGLE FACE WITH INDICATION ARROW DUAL FACES EXIT SIGN COMBO EXIT SIGN AND FROG EYES. BATTERY POWERED FROG EYES. REMOTE LANDING FIXTURE. PART 1 GENERAL - THIS SECTION DESCRIBES THE MATERIALS AND METHODS COMMON TO THE ELECTRICAL DIVISION OF WORK. PART 2 PRODUCTS 2.1 RACEWAY SYSTEMS A. ABOVE GROUND INTERIOR - HOT DIP GALVANIZED AS REQUIRED BY CODE OF EMT, IMC, OR RMC. B. BURIED AND UNDER CONCRETE SLABS - SCHEDULE 80 PVC W/ASPHALT COATED RMC ELBOWS WHERE PENETRATING SURFACE. 2.2 CABLE SYSTEMS - CONCEALED SPACES ONLY, TYPE AC OR MC CABLE AS ALLOWED BY CODE. 2.3 CONDUCTORS A. CONDUCTORS SHALL BE COPPER AND MINIMUM SIZE SHALL BE #12 AWG (20A MOCP) OR #14 (15A MOCP) EXCEPT AS OTHERWISE NOTED. B. INSULATION SHALL BE THWN-THHN EXCEPT AS OTHERWISE NOTED. C. ALL CIRCUIT CONDUCTORS SHALL BE RUN WITH EQUIPMENT GROUNDING AND WILL USE CONDUIT UNLESS OTHERWISE NOTED IN ACCORDANCE WITH NEC 250.122. 2.4 PANELBOARDS - PROVIDE PANELBOARDS W/BOLT-ON CIRCUIT BREAKERS EXCEPT AS OTHERWISE NOTED. SEE PANEL SCHEDULE FOR CAPACITY, RATINGS, SPACES, VOLTAGE, PHASE, MOUNTING, AND OTHER OPTIONS TO BE PROVIDED. 2.5 LOAD CENTERS - PROVIDE LOAD CENTERS W/PUSH-ON CIRCUIT BREAKER EXCEPT AS OTHERWISE NOTED. SEE PANEL SCHEDULE FOR CAPACITY, RATINGS, SPACES, VOLTAGE, PHASE, MOUNTING, AND OTHER OPTIONS TO BE PROVIDED. 2.6 GFCI - ALL GFCI SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION PER NEC 210.8. 2.7 ALL CONNECTED TERMINATIONS, CONDUCTORS, AND DEVICES SHALL HAVE A MINIMUM TEMPERATURE RATING OF 75'C, UNLESS OTHERWISE NOTED. PART 3 EXECUTION. 3.1 RACEWAY SYSTEMS A. RUN CONDUIT PARALLEL WITH AND AT RIGHT ANGLES TO BUILDING LINES. B. PROVIDE 1 EMPTY 3/4" CONDUIT FOR EVERY 3 UNUSED SPACES IN FLUSH MOUNTED PANELBOARDS OR LOAD CENTERS. C. PROVIDE FLEXIBLE CONDUIT ON CONNECTIONS TO VIBRATING EQUIPMENT. CONDUIT AND GROUNDING MEANS SHALL BE PER NEC. 3.2 IDENTIFICATION OF EQUIPMENT A. IDENTIFY EACH DISCONNECT SWITCH, TRANSFORMER, PANELBOARD, LOAD CENTER, AND ALL OTHER ELECTRICAL EQUIPMENT IDENTIFIED BY A PLAN CODE ON THE DRAWINGS. B. NAMEPLATES SHALL BE ENGRAVED IN LAMINATED PLASTIC, 3/8" HIGH AND ATTACHED WITH SCREWS. C. ALL PANELBOARDS AND LOAD CENTERS SHALL HAVE TYPE -WRITTEN DIRECTORIES INSERTED ON THE INSIDE FACE OF THE DOOR IDENTIFYING EACH CIRCUIT. D. ALL COMPONENTS OF EMERGENCY CIRCUITS SHALL BE PAINTED RED. 3.3 LIGHTING A. ALL EGRESS LIGHTING AND EXIT SIGNS SHALL BE PROVIDED WITH A CONSTANT HOT PER EACH CIRCUIT THAT IS INDICATED PER PLAN. DESIGN SUMMARY FOR PLAN REVIEWER GOVERNING CODES: 2017 NEC, 2018 IECC COMCHECK: LIGHTING COMCHECK — YES — ON PLANS �,w o v V � N v iN N �ZZ. Q� v 01 ro W We M W JLu Z WM c� LL Z a) c � XY W 2uu M. z z w w 0 0 I au.II_var:&� �m V Z C7 C7 O O co w0 �U Q Lu �-- 0 c Q Lo LU 0) N 19-016 SHEET NO. E3-000 .............. TtUG% "i 227 5 � IIIIIIIIIIIINU\\\ �v V� N F= N ZiN N oQ Q� NOI M �Wi � M W Z JW mol g LL w IZw .�Y Lu a00W2um STORAGE CH UNIT—" TYPICAL URE 1&2 EXIIMM UNITTYP REPLACEMENT SHOWN E3-201 11p REMAN 802: FOR THIS UNIT. z z z z LAUNDRY [] w w D Z UO > O Ll o O o O U co N co „ Cr'I w D O U LL K O U {`Il'} 0 0 Ll 0 0 0 N 0 N 0 N O N O N O N Wo NN 0 O O O PLAN DATES MECHANICAL W UNIT B2 W UNIT TYPE: 3-2.6 802 S.F. W o H— 0 0 of Of m C O 0o� • �--� U O U N W �Lu C 0 H� � O 0 O 7 UP 1 , VJ UNIT NOTES (2 UNITS IN BASEMENT) COMMON AREA NOTES v 1. BRANCH CIRCUIT TERMINATION POINTS DO NOT MOVE, BUT ALL FIXTURES WILL BE 1. REPLACE EXISTING CORRIDOR LIGHTS WITH LED FIXTURES. ATTACH CU PIGTAILS TO AL WIRING AS + REPLACED/UPGRADED. DONE FOR UNIT WIRING. , 2. ATTACH CU PIGTAILS TO ALL ALUMINUM BRANCH CIRCUIT WIRING AT EVERY OUTLET AND SPLICE BOX FOR WIRE SIZE #8 AND SMALLER CONDUCTORS. USE ONLY COPALUM OR ALUMICONN CONNECTORS. BASEMENT. 2. REPLACE EXISTING EXIT LIGHTING WITH NEW FIXTURES WITH EM LIGHTING WHERE APPROPRIATE. /051' p���4\c�' ! 3. REPLACE EMERGENCY EXIT LIGHTING. M � � J 3. GFCI RECEPTACLES TO BE USED IN ALL LOCATIONS SPECIFIED IN NEC 210.8 II�� 4. RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE TAMPER—RESISTANT PER 2017 NEC `J 406.12 REQUIREMENTS. Z 5. REPLACE OR ADD SMOKE ALARMS. 0 6. REPLACE ZINSCO BRAND ELECTRICAL PANELS, IN UNITS THAT HAVE THEM. J 7. A MAXIMUM OF 12 UNITS IN BUILDING MAY HAVE THEIR EXISTING RANGE HOOD REPLACED WITH A MICROWAVE. M W I W 0L C`7 O n( O `J 00 Lu vJ Q W � D CO H LU QLo O) 2 U�� 19-016 SHEET NO. ®Norm BLDG 3 BASEMENT E3-100 SCALE: 1/8" = 1 0" DEMO HAL FLOOD CIF (N) CONC. RAMP TO EXTI FOLLOW ADA STANDARDS (E) CONC. STOOP & BRICK HAND RAIL WALLS TO BE DEMOLISHED & REBUILT NO LESS THAN 1/2" BELOW FINISH FLOOR UNIT NOTES (10 UNITS ON FIRST FLOOR 1. BUILDING 3 LEVEL 1 HAS 2 UNITS CONVERTED TO BE ADA COMPLIANT. THESE WILL REQUIRE ALL NEW CIRCUITING INCLUDING NEW PANEL. 2. FOR REMAINING 8 UNITS BRANCH CIRCUIT TERMINATION POINTS DO NOT MOVE, BUT ALL FIXTURES WILL BE REPLACED/UPGRADED. 3. ATTACH CU PIGTAILS TO ALL ALUMINUM BRANCH CIRCUIT WIRING AT EVERY OUTLET AND SPLICE BOX FOR WIRE SIZE #8 AND SMALLER CONDUCTORS. USE ONLY COPALUM OR ALUMICONN CONNECTORS. 4. GFCI RECEPTACLES TO BE USED IN ALL LOCATIONS SPECIFIED IN NEC 210.8 5. RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE TAMPER—RESISTANT PER 2017 NEC 406.12 REQUIREMENTS. 6. REPLACE OR ADD SMOKE ALARMS. 7. EXTERIOR PATIO LIGHTS — ADD NEW 'DG' FIXTURES AT PATIOS. USE HOUSE PANEL CIRCUIT, AND CONTROL WITH PHOTO SENSOR. 8. REPLACE ZINSCO BRAND ELECTRICAL PANELS, IN UNITS THAT HAVE THEM. 9. A MAXIMUM OF 12 UNITS IN BUILDING MAY HAVE THEIR EXISTING RANGE HOOD REPLACED WITH A MICROWAVE. I ST FLOOR BLDG 3 1 ST FLOOR SCALE: 1/8" = 1' — 0" COMMON AREA NOTES 1. FOR ALL FIXTURE REPLACEMENT WHERE EXISTING WIRING IS AL, ATTACH CU PIGTAILS AS DONE FOR UNIT WIRING. 2. REPLACE EXISTING CORRIDOR LIGHTS WITH NEW (TYPE 'CD') FIXTURES. USE BATTERY BACKUP (TYPE 'CD—EM') WHERE SHOWN. 3. REPLACE EXISTING SIDE EXIT LIGHT WITH NEW FIXTURE (1—TYPE 'CG3'). 4. ADD NEW EXTERIOR EXIT LIGHTING (2—TYPE 'CG'). 5. REPLACE EXIT LIGHTS (TYPE 'X1'). 6. REPLACE HALLWAY RECEPTACLES WITH NEW DECORA TYPE RECEPTACLES. 7. DEMO EXISTING ROOF MOUNTED PARKING FLOOD LIGHT AND RE—USE CIRCUIT FOR NEW EXTERIOR LIGHTING. gEL v �Z v � V N o1 W We W JW -Fuo, c mZ vC Lu 2u F z w Z O 0 d p K c o U Z N W O T p U K 0 0 N N O O N N O r W O N QV V O O I PLAN DATES I a a P4 fm V Z 00 �a� af w�� poro 0U Zm W o � p m O 0 V O LL 0 LW LL V J Y) Q W Q U C`7 C`7 O O 00 w0 �U Q Lu =U �o 00 Fy �Q Lo W rn= N 19-016 SHEET NO. E3-101 eIEREe FT:9R`a_ �O�PPO V V� N _ N Zyc q Z. V._ M 49 BALCO LCONY Z W W W M mol g LL JW .�Y IZw W 2c m CE • UNIT 120 UNIT TYPE: 3-2.5 W UNIT 116 UNIT 117 UNIT 118 UNIT 119 698 S.F. NIT TYPE: 3-2.3 UNIT TYPE: 3-2.2 UNIT TYPE: 3-2.2 UNITTYPE:3- 2 DEMO EXISTING 8OW 698 S.F. 806S- --- S.F. ❑ 806 S.F. �� FLUORESCENT FIXTURES o REPLACE EXISTING CORRIDOR WALL o o z z REPLACE WIT SCONCE WITH NEW LED WALL SCONCE. LED PENDANT LI O jEXISTING CIRCUITING TO REMAIN. / O El G3 � � 13'- 10" 0 0 (TYPICAL OF ALL) 0 0 E (� 0 Q Oo Q 0 00 // O o �J ® BA CO Y - a TO CD CD CD CD 00 Of F O F BEL X CD CD CORRIDOR Cp Cp o o o Lx_ X2 X1 Ll o O ° ° af 00 Fi CO Y O O D Ll ❑_0 0rel_Q �l 0 W O O NN O O ® ® ® 0 PLAN DATES 0 0 0 ° O 0 0 ° 0 0 0 0 UNIT 11 UNIT 114 UNIT 113 UNIT 112 a UNIT TYPE: 3-2.3 UNIT TYPE: 3-2.2 UNIT TYPE: 3-2.2 4 UNIT TYPE: 3-2.2 698 S.F.TYPICAL FIXTURE -5 S.F. F. 611 S.F. UNIT 111 REPLACEMENT SHOWN 3&4 UNIT TYPE: 3-2.5 ` ^ W o FOR THIS UNIT. E3-ZO1 698 S.F. ® �v O o O z f O Lu 0 � c' 00ro �I N 0zm W O 00 m �lE= O 0 O BALCO LCONY BALCON �G +� UNIT NOTES (10 UNITS ON SECOND FLOOR) COMMON AREA NOTES v 1. BRANCH CIRCUIT TERMINATION POINTS DO NOT MOVE, BUT ALL FIXTURES AND DEVICES WILL BE 1. FOR ALL FIXTURE REPLACEMENT WHERE EXISTING WIRING IS AL, ATTACH CU PIGTAILS AS DONE , �402 REPLACED/UPGRADED. FOR UNIT WIRING. D=y. 2. ATTACH CU PIGTAILS TO ALL ALUMINUM BRANCH CIRCUIT WIRING AT EVERY OUTLET AND SPLICE BOX 2NDFLOOR 2. REPLACE EXISTING CORRIDOR LIGHTS 'CD—EM') WITH NEW (TYPE 'CD') FIXTURES. USE BATTERY BACKUP M J FOR WIRE SIZE #8 AND SMALLER CONDUCTORS. USE ONLY COPALUM OR ALUMICONN CONNECTORS. (TYPE WHERE SHOWN. 3. GFCI RECEPTACLES TO BE USED IN ALL LOCATIONS SPECIFIED IN NEC 210.8 3. REPLACE EXIT LIGHTS (TYPE 'X1') � 4. RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE TAMPER—RESISTANT PER 2017 NEC 4. REPLACE HALLWAY RECEPTACLES WITH NEW DECORA TYPE RECEPTACLES. Z 406.12 REQUIREMENTS. 5. DEMO EXISTING FLUORESCENT FIXTURE AT HALLWAY END AND REPLACE WITH LED PENDANT Q 5. REPLACE OR ADD SMOKE ALARMS. LIGHT. J 6. REPLACE THE 5 EXTERIOR BALCONY LIGHTS WITH NEW (TYPE 'DG') FIXTURES. �M�•y•� 7. REPLACE ZINSCO BRAND ELECTRICAL PANELS IN UNITS THAT HAVE THEM. W 8. A MAXIMUM OF 12 UNITS IN BUILDING MAY HAVE THEIR EXISTING RANGE HOOD REPLACED WITH A MICROWAVE. I W 0L C`7 O n( O LJ 00 Lu Y) Q W � D Co H UJ QLo rn 2 U�� 19-016 ®NoRTH BLDG 3 2ND FLOOR SHEET NO. SCALE: 1/8" = 1' 0" E3-102 UNIT DIAMOND NOTES 1O (NOT USED) O PROVIDE A GFCI DUPLEX RECEPTACLE LOCATED BELOW KITCHEN SINK FOR CONNECTION OF GARBAGE DISPOSAL AND DISHWASHER. PROVIDE AN AIR -SWITCH FOR DISPOSAL CONTROL, AS REQUIRED. O3 (NOT USED) O4 1 SWITCH FOR FAN CONTROL, 1 SWITCH FOR LIGHT CONTROL. ACCESSIBLE UNITS GENERAL NOTES 1. CONTROLS, OPERATING MECHANISMS AND HARWARE INTENDED FOR OPERATING BY THE OCCUPANT INCLUDING SWITCHES THAT CONTROL LIGHT AND VENTILATION AND ELECTRICAL CONVENIENCE OUTLETS IN ACCESSIBLE SPACES, ALONG ACCESSIBLE ROUTES OR AS PARTS OF ACCESSIBLE ELEMENTS SHALL BE ACCESSIBLE. (IBC 1109.13) 2. ALARM SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISIBLE ALARMS (HARD -WIRE EQUIPMENT) AND COMPLY WITH IBC 907.9.1 TABLE 907.9.1.3. 3. LIGHT SWITCHES IN ACCESSIBLE UNITS SHALL BE LOCATED AT +38" AFF UNLESS NOTED OTHERWISE. 4. CONVENIENCE RECEPTACLES SHALL BE LOCATED AT +18" AFF UNLESS NOTED OTHERWISE. 5. TYPICAL UNIT GENERAL NOTES AND SHEET NOTES ON THIS SHEET ALSO APPLY TO ACCESSIBLE UNITS. 6. ACCESSIBLE UNITS SHALL COMPLY WITH ANSI -A117.1. RE: GENERAL NOTES ON THIS SHEET FOR ADDITIONAL ACCESSIBLE UNIT INFORMATION AND REQUIREMENTS. 7. COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE OPTIONAL REMOTE ACCESSIBLE CONTROLS FOR RANGE HOOD/LIGHTS PRIOR TO ORDERING OR INSTALLING HOOD EQUIPMENT. 8. PROVIDE REMOTE SPST TOGGLE SWITCH FOR CONTROL OF RANGE HOOD VENT/LIGHT AT COUNTER HEIGHT. VERIFY EXACT LOCATION WITH MILLWORK DRAWINGS/ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. 9. ACCESSIBLE SLEEPING ACCOMMODATIONS SHALL HAVE A VISUAL ALARM CONNECTED TO THE BUILDING EMERGENCY ALARM SYSTEM OR SHALL HAVE A STANDARD 110V ELECTRICAL RECEPTACLE INTO WHICH SUCH AN ALARM COULD BE CONNECTED. INSTRUCTIONS FOR USE OF THE AUXILIARY ALARM OR CONNECTION SHALL BE PROVIDED. TYPICAL UNIT GENERAL NOTES 1. COORDINATE ALL LUMINAIRE LOCATIONS WITH GENERAL CONTRACTOR AND ALL OTHER TRADES PRIOR TO ROUGH -IN AND LOCATE ALL LUMINAIRES TO AVOID DUCTWORK, DEVICES, ETC. TO SUIT FIELD CONDITIONS. 2. DWELLING UNIT CONVENIENCE RECEPTACLE OUTLETS SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND SHALL ALSO COMPLY WITH NEC 210.52 REQUIREMENTS. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND LOCATE ALL GENERAL PURPOSE CONVENIENCE OUTLETS AS REQUIRED PER CODE WHETHER INDICATED ON THE DRAWINGS OR NOT. MOUNT AT +18" AFF UNLESS NOTED OTHERWISE. THE BOTTOM OF RECEPTACLE SHALL BE A MINIMUM OF 15" AFF. ABOVE COUNTER RECEPTACLES SHALL NOT EXCEED 46" AFF MEASURED TO THE CENTERLINE OF THE HIGHEST RECEPTACLE. 3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE PROPER BRANCH CIRCUITING AND COMPLIANT DEVICES THROUGHOUT ALL DWELLING UNITS PER NEC 210 REQUIREMENTS. 4. ALL 120V SINGLE PHASE, 15 AND 20A BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN ALL ROOMS SPECIFIED IN 2017 NEC 210.12(A) SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. 5. 120 VOLT SMOKE ALARMS SHALL BE PROVIDED AND INSTALLED ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS AND IN EACH ROOM USED FOR SLEEPING PURPOSES IN ACCORDANCE WITH IBC 907.2.10.1.2. 6. PENETRATIONS IN FIRE RATED ASSEMBLIES SHALL COMPLY WITH IBC 712.3.2 REQUIREMENTS. 7. LIGHT SWITCHES SHALL BE LOCATED AT +48" AFF TO THE TOP OF TOGGLE IN ON POSITION UNLESS NOTED OTHERWISE. 8. REFER TO ACCESSIBLE UNIT NOTES FOR ADDITIONAL INFORMATION AND REQUIREMENTS FOR ACCESSIBLE UNITS. ACCESSIBLE UNITS ARE IDENTIFIED AS TYPE "A" UNITS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND ADDITIONAL INFORMATION AND REQUIREMENTS. 9. APARTMENT WIRING AND DEVICE LAYOUTS ARE TYPICAL FOR ALL SIMILAR DWELLING UNIT TYPES UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO ADAPT LAYOUT(S) INDICATED FOR ALL SIMILAR UNITS AS REQUIRED. 10. COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE REMOTE ACCESSIBLE CONTROLS FOR RANGE HOOD/LIGHTS PRIOR TO ORDERING OR INSTALLING HOOD EQUIPMENT. 11. RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE TAMPER-RESISTANT PER 2017 NEC 406.12 REQUIREMENTS. 12. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL BRANCH CIRCUIT WIRING WITHIN DWELLING UNITS PER 2017 NEC 210.52 REQUIREMENTS. REFER TO TYPICAL UNIT PANEL SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS NOT INDICATED HEREON. 13. PROVIDE SWITCHED 20A 120V RECEPTACLE UNDER COUNTER FOR GARBAGE DISPOSAL. VERIFY LOCATION WITH PLUMBING CONTRACTOR PRIOR TO ROUGH -IN. 1/2 -HOT 20A 120V RECEPTACLE UNDER COUNTER FOR DISHWASHER (BREAK STRAP ON RECEPTACLE FOR DUAL -CIRCUIT CONFIGURATION. RE: PROVIDE 2 -POLE CIRCUIT BREAKER PER CODE REQUIREMENTS). 14. PROVIDE SINGLE -STATION 120V COMBINATION SMOKE ALARM/ CO SENSOR WITH BATTERY BACKUP PER IBC 907.2.10.1.2 AND 907.2.10.2. WHERE MORE THAN ONE ALARM IS REQUIRED WITHIN AN INDIVIDUAL DWELLING UNIT, THE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE DWELLING UNIT. 15. DUPLEX RECEPTACLES MOUNTED ABOVE COUNTER TOPS SHALL BE MOUNTED SUCH THAT THE TOP OF THE RECEPTACLE DOES NOT EXCEED 46" AFF. 16. UNDER -COUNTERTOP RECEPTACLES SHALL BE MOUNTED NO MORE THAN 12 INCHES BELOW THE COUNTERTOP AND SHALL NOT BE LOCATED WHERE THE COUNTERTOP EXTENDS MORE THAN 6 INCHES BEYOND ITS SUPPORT BASE. REFER TO NEC 210.52(C)(5) EXCEPTION TO (5). 17. ALL KITCHEN COUNTER -TOP RECEPTACLES SHALL SHALL COMPLY WITH ALL FHA REQUIREMENTS. 18. EXISTING HVAC EQUIPMENT TO BE RECONNECTED TO NEW UNIT LOAD CENTER. STROBEO RS STROBE STROBEO LINE OF FLR. ABOVE DF q,r DF n,p ro LINE OF FLR. ABOVE O WP UNIT 105 z NIT TYPE: 3- MIQRQ 698 S.F. AFI TYPE A AFI W 2 DISH. HOOD DISP. RANGE -� REAC +414„ GFS 84F. AC " GF6 GFI BLDG 3 ADA D�k PAINT ALL WALL -(#8-3 CU)NM REPLACE ALL W UNIT POWER SCALE: 1/4" = 1' - 0 +84" 5 r DA DA °'L UNIT 105 NIT TYPE: 3-2. 698 S.F. D­A� TYPE A 110 PAINT ALL WALL REPLACE ALL W LIGHTING 1/4" = 1' - 0" . �a, 0 0 00 Lu O LU Q Lu _ Q �-- 0 00 - Q Lo W_ N 0) 19-016 SHEET NO. E3-200 z z W W Z > a C,cl U co N co (n WOE: Z Z O D U K U 0 N 0 N 0 N W F__ O N N 0 0 0 PLAN DATES a Oo zOf m O C, 0 • P�1 U OUN W O w o E- U Q H� O 0 O �O r^ /1 0 0 00 Lu O LU Q Lu _ Q �-- 0 00 - Q Lo W_ N 0) 19-016 SHEET NO. E3-200 ````PPO ..E...... rT �9 `O •c tog REPLACE EXISTING SWITCHES �� ^ WITH NEW (TYPICAL OF ALL SHOWN). REPLACE EXISTING LIGHT FIXTURES WITH NEW. ALL LOCATIONS AND OF 49� uc 1% WaWITH REPLACE EXISTING RECEPTACES WIRING IS EXISTING TO REMAIN. D O -g NEW (TYPICAL OF ALL SHOWN). ALL LOCATIONS AND 10a Lu JZ `-'� c ACS WIRING IS EXISTING TO REMAIN. i ��UNIT B1 GFI u,41T B1 '1 mW2s mUNIT TYPE: 3-2.6 UI41T TYPE: 3-2.6� 1 802 S.F. � 02 S.F. W AC GFI i z z z z AC DE ` w � w � GFI O O O a o cl DISP. 10 DH DF r C) � co N � co DISH. GFI 1 DA 0 00 Z Of0 Z O AC 0 N 0 N 0 N REF.AC HOOD AC GFI OIL: W O N N GFI GFI Q� O 0 0 0 0 PLAN DATES RANGE � a F-1 o o n o o UNIT FIXTURE REPLACEMENT DIAMOND NOTES OADD GFCI RECEPTACLE BELOW KITCHEN SINK FOR CONNECTION OF DISHWASHER IF mtzt a CURRENTLY HARD -WIRED. ` ^ jT4 '0 UNIT3-2.6 P0WER UNIT 3-2.6 LIGHTING O ADD FAN SUPPORT BAR IF NOT CURRENTLY INSTALLED. P4 0 0, 1SCALE 1/4" = 1' - 0" % SCALE 1/4" = 1' - 0" O WITH UP TO A MAXIMUM OF 12 UNITS, CONVERT HARD -WIRED HOOD FAN TO RECEPTACLE FOR MICROWAVE. ENSURE MICROWAVE IS ON DEDICATED CIRCUIT. IF O U O p • rj UNABLE TO SUPPLY DEDICATED CIRCUIT, REPLACE EXISTING RANGE HOOD WITH NEW W O z m RANGE HOOD. o OIF EXISTING UNIT PANEL IS ZINSCO BRAND, REPLACE WITH NEW 100A PANEL. x °� 0 VJ DISP. DISH. v 0 1 ♦ o o �Gi/pyo ACAC o GFI ac AC ® `y y` GFI GFI GFI DEF__DB g . DF � M O 4DD AC Z GFIREF. AC O GFO3 HOOD O0 RANGE UNIT 114 DCUNIT 114 4 UNIT TYPE: 3-2.2 UI - -----IT TYPE: 3-2.2 UI806 NIRING S.F. ""' `' rEPLACE EXISTING SWITCHESREPLACE EXISTING RECEPTACES / ITH NEW (TYPICAL OF ALL SHOWN). WITH NEW (TYPICAL OF ALL EPLACE EXISTING LIGHT FIXTURES uiITH HOWN). ALL LOCATIONS AND WIRING IS EXISTING TO REMAIN. NEW. ALL LOCATIONS AND IS EXISTING TO REMAIN. Cy) DF i DF O 00 O O 0 W Q Lu � 0 0 Q� A/C 00 - W � Q Lo LLJ BALCONYGFl E BALCON E U 19-016 SHEET NO. UNIT 3-2.2 POWER UNIT 3-2.2 LIGHTING 3 SCALE: 1/4" = 1' - 0" SCALE: 1/4" = 1' - 0" E3-201 PARTNER Engineering and Science, Inc. ASBESTOS & LEAD-BASED PAINT SURVEY REPORT Caesar's Square Apartments 9235-9355 West 48th Avenue Wheat Ridge, Colorado 80033 o¢ober 2,2019 Partner Project No. 19-258685.2 Prepared for'. 1" Bank 4350 Waaswonb BoweoaN Wheat Ridge, CO 80033 PARTNER Engineering and Science, Inc: October 2, 2019 David Schafer 1st Bank 4350 Wadsworth Boulevard Wheat Ridge, CO 80033 303-456-2182 david.schaferCcbefirstbank.co m Subject: Asbestos and Lead-based Paint Survey Report Caesar's Square Apartments 9235-9355 West 48th Avenue Wheat Ridge, Colorado 80033 Partner Project No. 19-258685.2 Dear Mr. Schafer: Partner Engineering and Science, Inc. (Partner) is pleased to provide the results of the Asbestos & Lead-based Paint Survey of the abovementioned address (the "subject property'. This survey was performed in general conformance with the scope and limitations as detailed in our fee proposal. This survey included a site reconnaissance as well as sampling and analysis. An assessment was conducted, conclusions stated, and recommendations outlined, as necessary. We appreciate the opportunity to provide environmental services to 1' Bank. If you have any questions concerning this report, or if we can assist you in any other matter, please contact me at (715) 572-1408. Sincerely, Partner Engineering and Science, Inc. . AJ Nosekk National Client Manager 2154 Torrance Blvd., Suite 200, Torrance, CA 90501 0 Phone 800-419-4923 0 Fax 866-928-7418 TABLE OF CONTENTS 1.0 INTRODUCTION ................................................................................................................................................... I 1.1 Property Description ......................................................................................................................................... 1 1.2 Purpose and Scope ........................................................................................................................................... 1 1.3 Methodology ...................................................................................................................................................... 1 2.0 ASBESTOS/LEAD SURVEY ............................................................................................................................... 4 2.1 Visual Inspection ................................................................................................................................................ 4 2.2 Testing Results .................................................................................................................................................... 4 3.0 CONCLUSION ........................................................................................................................................................ 9 4.0 LIMITATIONS ...................................................................................................................................................... 11 5.0 SIGNATURES OF PROFESSIONALS ........................................................................................................... 12 Appendices Appendix A Laboratory Analysis and Chain -of -Custody Appendix B Sample Locations Appendix C Certifications Appendix D Photographic Documentation Asbestos and Lead-based Paint Survey Project No. 19-258685.2 October 2, 2019 PARTNER Page i 1.0 INTRODUCTION 1.1 Property Description 1.2 Purpose and Scope The purpose of this asbestos survey and lead-based paint inspection (survey) was to sample and analyze suspect asbestos -containing materials (ACM) and suspect lead-based paint (LBP) which could present an exposure risk during potential renovation activities. The suspect materials sampled during the survey were limited to accessible areas within the interior and exterior of the building. No renovation scope was provided to Partner prior to conducting the survey. Twenty-six (26) units were accessed at the site to evaluate the presence of suspect ACM and LBP. 1.3 Methodology ASBESTOS Suspect ACM were sampled according to the guidelines set forth in 40 CFR Part 763, and later analyzed using the Polarized Light Microscopy (PLM) method in accordance with the EPA reference method 600/R-93/116 for Determination of Asbestos in Bulk Building Materials. The United States Environmental Protection Agency (USEPA) as set forth in 40 CFR 763, defines a homogeneous area as "an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color and texture." The regulation requires that a minimum number of representative samples be collected from each homogeneous area to confirm that the material is not an ACM. If asbestos is identified in any samples from a homogeneous area, the entire homogeneous area is considered to contain asbestos. The aforementioned testing and analytical constraints can affect the findings and recommendations of this survey. Specifically, no assurance is given regarding the asbestos content of the samples beyond these parameters. The ACM most likely to release asbestos fibers are those which are in a friable state. Friability describes the condition of asbestos. The definition of friable is any material, when dry, that is capable of being crumbled, pulverized or reduced to powder by hand pressure (40 CFR 763). Non -friable sources of asbestos are materials containing cement or asphalt binder which may become friable and release fibers if the sources are exposed to actions such as abrasion, drilling, Asbestos and Lead-based Paint Survey PARTNER Project19-258685.2 Octoberr 2, 2, 2019 Page 1 cutting, fracturing or hammering. Non -friable sources of asbestos do not typically pose a significant exposure risk if they remain in good condition and are not disturbed. During renovation or demolition activities, non -friable sources may become friable and thus may pose an exposure risk. The PLM method is the most commonly used method to analyze building materials for the presence of asbestos. This method utilizes the optical properties of minerals to identify the selected constituent. The use of this method enables identification of the type and the percentage of asbestos in a given sample. The detection limit of the PLM method for asbestos identification is typically one percent (1%) asbestos. The Colorado Department of Public Health and Environment regulations define an ACM as any material which contains greater than one percent (1 %) asbestos. LEAD-BASED PAINT A lead-based paint inspection is a surface -by -surface investigation to determine the presence of lead-based paint and the provision of a report explaining the results of the investigation. Partner utilized a Niton XLP-300A (serial no. 94979) X -Ray Fluorescence (XRF) analyzer to conduct this survey. The XRF uses a Cadmium 109 (Cd) isotope radioactive source to 'excite' the atomic structure of painted surfaces. Once 'excited, lead (Pb) atoms emit unique x-ray emission. The radiation detector within the XRF then translates these x-rays into a quantitative measure of lead concentration. If present, the XRF will determine the amount of lead in paint with a 95% confidence level. The lead concentrations are reported in milligrams per square centimeter (mg/cmc). Measurements were taken at locations representative of all painted or varnished surfaces for each different testing combination in the areas inspected. In order to obtain a reading, the XRF analyzer is placed with the face of the instrument flush against the surface to be tested. Itis then held in place for the duration of the sample, approximately 4 to 16 source seconds, or until the measurement has reached the acceptable range of accuracy. The sampling time is dependent on the age of the radioactive source inside the XRF. XRF analysis yields the total lead content of a painted surface, and not distinguishing between individual concentrations of painted layers. The XRF was calibrated with a National Institute of Standards and Testing (NIST) calibration surface priorto and post analysis of painted surfaces. The subject property's orientation is described using HUD's recommended guidelines, assigning the letters A, B, C and D to each side. Side A corresponds to the main entrance of each building. The remaining side identifications are assigned in a clock -wise manner. Each tested component location is identified using the building's assigned letter as a reference point. The Colorado Department of Public Health and Environment Regulation 19 defines LBP as paint or other surface coating that contains any amount of lead equal to or in excess of 1.0 mg/cmc or more than 0.5% by weight. Asbestos and Lead-based Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page 2 Lead-based paint may be present in buildings constructed in 1978 and earlier. In general, there are many other building materials which can contain lead in the average building. When conducting construction or demolition activities which disturb lead in any amount or create an exposure to workers, the employer is required to provide worker protection and conduct exposure assessments. Employers should consult Federal OSHA Regulations at 29 CFR 1926.62, "Lead in Construction" standards for complete requirements prior to construction or demolition activities. Notification must be given to all other contractors at the work site prior to the start of activities that may create a lead hazard. Characterization and disposal of lead -containing waste materials (LCWMs) must comply with federal, state and local authorities. Contractors must maintain current licenses as required by applicable state or local jurisdictions for the removal, transport, disposal of LCWMs, or other regulated lead-based paint activities. Asbestos and Lead- based Paint Survey PARTNER Project19-258685.2 Octoberr 2, 2, 2019 Page 2.0 ASBESTOS/LEAD SURVEY 2.1 Visual Inspection During the course of the property visit, John Burnside, performed a review of accessible areas of the subject building for the presence of suspect ACM and LBP. The purpose of this assessment is for renovation purposes only, therefore, additional suspect ACM and/or LBP could be present. No renovation scope was provided to Partner prior to conducting the survey. Partner did not attempt to disassemble mechanical equipment, open pipe chases, or assess materials within wall voids. Regardless of the thoroughness of a survey, the possibility exists that some areas containing ACM and/or LBP were not identified, inaccessible, or different from those materials at specific locations. Caesar's Square Apartments consists of five apartment buildings constructed of brick and concrete. 9235 & 9265 West 481h Avenue have exterior metal stairs for external access to each apartment unit. 9295, 9325 and 9355 West 48th Avenue have interior hallways and stairs to allow access to each apartment unit. Buildings 9235, 9265 and 9295 had heavy textured ceilings (popcorn) and Buildings 9325 and 9355 had ceilings with finishes similar to the sprayed texture present on the drywall walls. Floors were typically carpet or vinyl. ASBESTOS Suspect asbestos -containing materials observed at the time of the inspection were sampled and analyzed for asbestos content. The survey also established whether any of the substrates sampled could be considered friable and/or significantly damaged or capable of immediate worker exposure. LEAD-BASED PAINT— XRF TESTING PROTOCOL During the course of the property visit, John Burnside, performed a review of accessible areas of the subject building for the presence of suspect LBP. The painted/finished surfaces containing suspect LBP were analyzed and the data was recorded using an XRF. 2.2 Testing Results ASBESTOS Twenty-six (26) units were accessed at the site to evaluate the presence of suspect ACM. A total of eighty (80) bulk samples of suspect ACM were collected for analysis. The samples were grouped into homogeneous categories, assigned individual sample numbers, sealed in plastic bags, and transported under proper chain -of -custody documentation to LA Testing. LA Testing is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP No. 200232-0) for the analysis of asbestos bulk samples. Refer to Appendix A for analytical data. The analytical results are summarized in the table below: Asbestos and Lead-based Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page4 Bulk Sample Analytical Results for Analysis of Asbestos Content Sample No. Location Description Asbestos Content 1C01 Unit 9235- Office Ceiling texture 5% Chrysotile 1CO2 Unit 9235- Office Ceiling texture 5% Chrysotile 1CO3 Unit 9235-06 Ceiling texture 5% Chrysotile 1C04 Unit 9235-19 Ceiling texture 5% Chrysotile 1C05 Unit 9235-19 Ceiling texture 5% Chrysotile 1C06 Unit 9235-20 Ceiling texture 5% Chrysotile 1C07 Unit 9235-11 Ceiling texture 5% Chrysotile 1W01 Unit 9235 -Office Drywall system w/ texture 2% Chrysotile 1W02 Unit 9235 -Office Drywall system w/ texture 2% Chrysotile 1W03 Unit 9235-06 Drywall system w/ texture 2% Chrysotile 1W04 Unit 9235 -Laundry Drywall system w/ texture ND 1W05 Unit 9235-19 Drywall system w/ texture 2% Chrysotile 1W06 Unit 9235-20 Drywall system w/ texture 2% Chrysotile 1W07 Unit 9235-11 Drywall system w/ texture 2% Chrysotile 1WVBA01 Unit 9235 -Office Vinyl base adhesive ND 1WVBA02 Unit 9235-06 Vinyl base adhesive ND 1F01 Unit 9235 -Office Vinyl flooring ND 1F02 Unit 9235-06 Vinyl flooring ND 1F03 Unit 9235 -Laundry Vinyl flooring 2% Chrysotile 1F04 Unit 9235-19 Vinyl flooring ND 2C01 Unit 9265-12 Ceiling texture 5% Chrysotile 2CO2 Unit 9265-12 Ceiling texture 5% Chrysotile 2CO3 Unit 9265-01 Ceiling texture 5% Chrysotile 2C04 Unit 9265-04 Ceiling texture 5% Chrysotile Asbestos and Lead-based Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page 5 Sample No. Location Description Content 2C05 Unit 9265-06 Ceiling texture 5% Chrysotile 2C06 Unit 9265-18 Ceiling texture 5% Chrysotile 2C07 Unit 9265-13 Ceiling texture 5% Chrysotile 2W01 Unit 9265-12 Drywall system w/ texture 2% Chrysotile 2W02 Unit 9265-12 Drywall system w/ texture 2% Chrysotile 2W03 Unit 9265-01 Drywall system w/ texture 2% Chrysotile 2W04 Unit 9265-04 Drywall system w/ texture 2% Chrysotile 2W05 Unit 9265-06 Drywall system w/ texture 2% Chrysotile 2W06 Unit 9265 -Laundry Drywall system w/ texture 2% Chrysotile 2W07 Unit 9265-13 Drywall system w/ texture 2% Chrysotile 2%Chrysotile — 2WVBA01 Unit 9265-12 Vinyl base adhesive Note 1 2WVBA02 Unit 9265-04 Vinyl base adhesive ND 2F01 Unit 9265-12 Vinyl flooring ND 2F02 Unit 9265-01 Vinyl flooring ND 2F03 Unit 9265-04 Vinyl flooring ND 3C01 Unit 9295-103 Ceiling texture 5% Chrysotile 3CO2 Unit 9295-107 Ceiling texture 5% Chrysotile 3CO3 Unit 9295-101 Ceiling texture 5% Chrysotile Unit 92951" floor SE 5% Chrysotile 3C04 Ceiling texture Hall 3C05 Unit 9295-102 Ceiling texture 5% Chrysotile 3C06 Unit 9295-205 Ceiling texture 5% Chrysotile 3C07 Unit 9295-205 Ceiling texture 5% Chrysotile 3W01 Unit 9295-103 Drywa II system w/texture 2% Chrysotile 3W02 Unit 9295-107 Drywall system w/ texture 2% Chrysotile 3W03 Unit 9295-101 Drywall system w/ texture 2% Chrysotile Asbestos Nand -258685.2 Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page 6 Sample No. Location Description Content 3W04 Unit 9295 -Laundry Drywall system w/ texture 2% Chrysotile Unit 92951" floor SE 2% Chrysotile 3W05 Drywa II system w/texture Hall 3W06 Unit 9295-102 Drywall system w/ texture 2% Chrysotile 3W07 Unit 9295-205 Drywall system w/ texture 2% Chrysotile 2%Chrysotile — 3WVBA01 Unit 9295-103 Vinyl base adhesive Note 1 3WVBA02 Unit 9295-101 Vinyl base adhesive ND 3F01 Unit 9295-101 Vinyl flooring ND 3F02 Unit 9295-101 Vinyl flooring ND 4W01 Unit 9325-08 Drywall system w/ texture 2% Chrysotile 4W02 Unit 9325-08 Drywall system w/ texture 2% Chrysotile 4W03 Unit 9325-17 Drywall system w/ texture 2% Chrysotile 4W04 Unit 9325-17 Drywall system w/ texture 2% Chrysotile 4W05 Unit 9325-18 Drywall system w/ texture 2% Chrysotile 4W06 Unit 9325-20 Drywall system w/ texture 2% Chrysotile 4W07 Unit 9325-12 Drywall system w/ texture 2% Chrysotile 4WVBA01 Unit 9325-08 Vinyl base adhesive ND 4WVBA02 Unit 9325-17 Vinyl base adhesive ND 4F01 Unit 9325-08 Vinyl flooring ND 4F02 Unit 9325-17 Vinyl flooring ND 4F03 Unit 9325-18 Vinyl flooring ND SW01 Unit 9355-10 Drywa II system w/texture 2% Chrysotile SW02 Unit 9355-10 Drywall system w/ texture 2% Chrysotile SW03 Unit 9355-03 Drywall system w/ texture 2% Chrysotile SW04 Unit 9355-06 Drywall system w/ texture 2% Chrysotile SWO5 Unit 9355-21 Drywall system w/ texture 2% Chrysotile Asbestos Nand -258685.2 Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page 7 Sample No. Location Description Content SW06 Unit 9355-21 Drywall system w/ texture 2% Chrysotile SW07 Unit 9355-13 Drywall system w/ texture 2% Chrysotile 2%Chrysotile — SWVBA01 Unit 9355-10 Vinyl base adhesive Note 1 SWVBA02 Unit 9355-03 Vinyl base adhesive ND SF01 Unit 9355-10 Vinyl flooring ND SF02 Unit 9355-03 Vinyl flooring ND Note 1 — Some of the vinyl base adhesive samples had drywall texture included with the sample as drywall texture was adhered to the adhesive and came off with the vinyl base adhesive when sampled. Documentation of the laboratory results should be retained as a reference for future renovation/ demolition activities. LEAD-BASED PAINT Twenty-six (26) units were accessed at the site to evaluate the presence of suspect LBP. A representative number of interior/exterior painted surfaces/components were tested for LBP at the subject properties. A total of 448 XRF readings (including 9 calibration readings) were collected throughout the subject property. No readings indicated a lead content greater than 1.0 or greater mg/cmc, which is the current regulatory threshold for the requirement of lead -safe work practices in the Colorado, as assessed using an XRF instrument. Additional readings confirmed detectable levels of lead in paint (less than 1.0 mg/cmc). Please see Appendix E for Suspect Lead -Based Paint Inspection Results. Analytical Results (LBP) No lead-based paint was detected during the sampling of the apartment units. The XRF results are available in Appendix E. LBP is defined under the US Department of Housing and Urban Development (HUD) and the Environmental Protection Agency (EPA) as paint or other surface coating with lead content equal to or greater than 1.0 mgl of surface area by XRF or 0.5% by weight (5,000 parts per million (ppm)) by paint chip analysis. Asbestos and Lead-based Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page 8 3.0 CONCLUSION ASBESTOS The following building materials were confirmed to contain asbestos • Heavy textured drywall ceilings in Building 1 (9235), Building 2 (9265) and Building 3 (9295) • Drywall wall systems in all buildings • Drywall ceilings in Building 4 (9325) and Building 5 (9355) • Vinyl flooring in the laundry rooms • Drywall texture attached to the vinyl base adhesive An Operations and Maintenance program should be prepared to provide for the proper training and appropriate work practices requires for employees to replace ceiling fixtures during current rehabilitation plans. A comprehensive and thorough inspection is required for a major renovation or demolition project in accordance with the EPA NESHAP (Asbestos). The roofs) appeared to be in good overall condition and were not sampled as a part of the survey. The EPA recommends that all ACM be removed by a certified asbestos contractor prior to any renovation or demolition activities that may impact the material. In the absence of planned renovation/demolition activities, the EPA recommends that ACMs be managed in-place whenever asbestos is identified in a building. Any damaged asbestos materials should be removed, repaired, encapsulated, or enclosed. Asbestos materials that are not damaged may be managed in place in accordance with a written Operations and Maintenance Program. Federal, state and local laws require building owners and/or their representatives, prior to any demolition and/or renovation operations which may disturb any asbestos -containing materials in their buildings, to meet the following requirements: • Notifications, • Remova l tech n iques(such as wetti ng)for asbestos-contai n i ng materials, • Clean-up procedures, • Waste storage and disposal requirements. The potential exists for additional suspect ACM to be exposed during demolition and/or renovation activities. Such materials should be sampled and analyzed for asbestos content prior to any renovation and/or demolition activities that could impactthese materials. LEAD-BASED PAINT During the inspection LBP was not identified at the subject building. Some of the samples contained detectable concentrations of lead below the threshold for LBP. Please note that OSHA does not recognize XRF results as a determination that lead is not present in surface coatings. Work activities impacting lead containing coatings pose a potential exposure risk for workers and/or building occupants. Workers trained in proper safety and respiratory techniques should Asbestos and Lead-based Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page perform renovation activities that may impact the lead containing coatings. All construction work where an employee may be occupationally exposed to lead must comply with OSHA requirements set forth in 29 CFR 1926.62. This regulation requires initial employee exposure monitoring to evaluate worker exposure during work that disturbs lead -containing materials (lead present in detectable levels). Partner recommends that representative coated surfaces be sampled via the paint chip method and analyzed via flame atomic absorption. Waste items generated during an abatement or demolition project should be properly sampled and profiled to determine the final disposition of the waste. The potential exists for additional suspect lead -containing materials to be exposed during demolition and/or renovation activities. Such materials should be sampled and analyzed for lead content priorto any renovation and/or demolition activities that could impact these materials. Asbestos and Lead-based Paint Survey PARTNER Project No. 19-258685.2 October 2, 2019 Page 10 4.0 LIMITATIONS Partner subcontracted with Eurofins — EMLab P&K to perform the asbestos analysis. No warranties expressed or implied, are made by Partner or its subcontractor Eurofins — EMLab P&K, or their employees as to the use of any information, apparatus, product or process disclosed in this report Every reasonable effort has been made to assure correctness. If an Asbestos and/or Lead Abatement Contractor or other Demolition/Construction Contractor is employed, such contractor should bring any discrepancies found in this report as it relates to current site conditions or newly discovered site conditions to the immediate attention of Partner. State-of-the-art practices have been employed to perform this asbestos and lead survey. The scope of this evaluation was severely limited to areas which were considered reasonably accessible (i.e., less than 15 feet from the floor), or within range of a visual inspection through reasonable means. No demolition or product research was performed in attempts to reveal material compositions. The services consist of professional opinions and recommendations made in accordance with generally accepted engineering principles/practices. These services are designed to provide an analytical tool to assist the client. Partner and its subcontractor Eurofins — EMLab P&K and their employees/representatives bear no responsibility for the actual condition of the structure or safety of this site pertaining to asbestos and/or lead contamination regardless of the actions taken by the survey team or the client. Any quantities of ACM/LBP listed are estimates only and not meant to be used to solicit abatement quotations. These quantities should be confirmed by abatement contractors prior to submitting bids for abatement. Asbestos and Lead-based Paint Survey PARTNER Project19-258685.2 Octoberr 2, 2, 2019 Page 11 5.0 SIGNATURES OF PROFESSIONALS Partner has performed a limited asbestos and LBP survey on the property at 9235-9355 West 48`h Avenue, Wheat Ridge, Colorado 80033 in general conformance with the scope and limitations of the protocol and the limitations stated earlier in this report Exceptions to or deletions from this protocol are discussed earlier in this report. Prepared By: Partner Engineering and Science, Inc. John Burnside Colorado Asbestos Building Inspector#21520 Colorado Lead -Based Paint Risk Assessor 11786 ?effre�Lger Jr. Project Manager — Industrial Hygiene Services Asbestos and Lead-based Paint Survey PARTNER Project19-258685.2 Octoberr 2, 2, 2019 Page 12 APPENDIX A: LABORATORY ANALYSIS AND CHAIN OF CUSTODY PARTNER CHAIN OF CUSTODY WEASHEn I Ind off. Jr. Cure LIS whow. EMLaEPK. wm en REQUESTED SERVICES f�aohae m II NJ Cast bull n lnot 871-19841 � E Pli What reuoxn Does Pnrcmu�AZ 85027 -Mass 651 4k tltltl Roberts S San FaA2e CAMi rowk OVISE Of Ste 203 S.So, FUri CA 9400 - (656)fiSeE653 Panner EntmeeMg BSagncs all Acd 9 Thei 1544 ALI did SWI, 160, RmevAu, CA H 5E61 rim. Me,, wAmg so,mn le"N'n, 2 day TAT requested mnmlo 19-251 iolap Daae. wheal Ridge Co a.6WC DM fl TIM, slang 09: e0 D NATO, STEP xQ.,uatl s0 wH.w . COLLINS(DEFAULT) Eo,in„a D,r same fivamea Day xu , x°llday Ruenm rerelved after 2Pm or On meexendi m1i be c°n9dere rved the nel Imma qday Pkeee Wont ua In advance or whakend analyse creme. smq.lo peanpnm Se,xaner TAT Type (AREAS p1 v um✓l xmEs SW so Sir/ ealowl 1 (as 1Tune of Tame, RH al avoe u9web /Ca/ Ce4c/uc re..✓f( D 2 DA4 By "i W this �Go3 loft roue bound IS the aenoml el one, 11l,dolr wmmarms mml v a /CO( C°er she 12002200 SOLVE Phe /LOS /�q n�.,m,m n.r,d L. IAl I.„.I.11ahn /La 6 /co> ✓ALL CO.ae/p✓MD /uif yea✓OL ST T D - °1 Jabn BumeW 912712019019 9 W : mer SW so Sir/ r avoe u9web By "i W this Chain of Custody loft roue bound IS the aenoml el one, 11l,dolr wmmarms mml v a C°er she 12002200 SOLVE Phe /�q n�.,m,m n.r,d L. IAl I.„.I.11ahn CHAIN OF CUSTODY WETTHEN FW mir SM. Why, Code roarer .EMLabPK.c[Im Noun REQUESTED&ERVII Neva,) MrXOM1 NJ Was Lurcrin Drive BAR,DrysMPM1YNoZ NJ lial0 100051-Jel 11 PU Nov _ - Pulassix el Frimo 501Weal Xn0ven 0llve.PMann, P205@) '10001851de01) 6000SF fv)CA re SnanmeQ are 303, s. sen Franuam. CP 9<OBO ' 1&661000609 Planar Enpineering &Stroll, 11, Am p 1564D 1544 drove Road Sure 180, Rival So95661 mm. Samurai Suisse rmamne 2 day TAT requested oia ID. u2sal al StradJQDEEAULTI Rushes nadeve0 after darn or m U d Joel Dam. wtaRAN, NO -Neq Ouain„a Day vseason0l will be CoConsulOei N Q Q pliq ecelved lbe nod business day, f do End Can 0009 od Dale S Time. SISSON 0900 ED -Sam, Bay,eaa Day Ruan Please aled us In ssbaW a of Jcold UNJ Ni PD : VON w. wea edend napais needs. o o e” N m _ p Seplae m [Insulation TressNavy, vdumdPm NOTES n a e ffi Ieabrvl ) Pe (Tri Rally TamP, All a at a /WO �,E/q�L orooa✓✓D S Tg1y //vO� y /✓9A0/ V✓✓c 9affjr Avii /✓9 /o/ S, % ✓c rcOOR,✓S IY0IWf�,I�irVP� / /W 0022602263/63 /vi /fel LE�t�✓f %Er(n za-d, Zcoa �/ 1fOL sT-Non,Raper a -ia erSIR SO soul L S Bu p, D Dan John armade 971 Pyy`�� No - By morsern0rule Chun of Cliltiody. g... 1, Meouno JV To Terms end ¢mmsa mns l loon al wm'embopeMml your MOnpy00M G 20T? SOTS P1WO Psx // U, amu., IRS, vn in, uurm Paovmu. om CHAIN OF CUSTODY WWw.EMLabPKcom BEwesreo sEBvmEs (v eoxe.l m.rbn rvi 8000 L"<mnD,we East Sued a M.ntonX, OeooB r0661 e7t-,day) Di e,SKnudsen DPenX. Az 85027 (800)65,48071 SSam F...m sales(ineb d, CA Make SOUP SAmlme At Ste 20A S San fivnmseo. CA 9000 ' Iaft 880E69 Paul, Engine eMpfl suenm ln[- root tlS05el ev o T80 Roseville Mal New Cause sPe�una a,a,ana 2 day TAT requested put l0. 19 AN6053 11 SrO.@zma,a REFA0T) Nuaees recewea after arm or d Ppae Seed Wheat Norge, CO ND NextBusiness Day Onweekends, will Ce conedere0 w Sampling eat nets us ass eav_ s o Code : Way Date Time . sI S 09: 00 SID Baine 8.11111, Oay Rase Please elan ae In aeoeRed of U u WN W Y w"kene able $,a nesse. _ A BiY Ple,iar BBE IT O S��Ple lO geoeprbn q (oboe Xol Marta X07E4 n ti_ (Below( 1 (as Rine oldav, ism s. RR. at, O a umbel sit f f Zm5 CAll u•Af Y£x��e' r'j 2PAY ZGO L RCO � I Zwoi L(/,ICG Cn./i"Ki Zmoal Z✓O� I I 0 02 2 63 16 002265FA, 3 takZAeylgs A'/(J I. 2Ve V,wrat BesF All day , ST srobµm S rape o. ,bnEe,.de anawrl7:a0 1 sW-swao so"se,l P od PNo,Palms Wall 00 -Arps. BY Sol by Cham o, Call 0, a are, to be hound by the linins Onocondrold At fent mv I wemlebok mmam ue e,ml Oersot 0300b20e9 EMMb p6µ 5/7 un..o, In 1w,4o,..,.,„. n a,ew. CHAIN OF CUSTODY vrvrvu.EMLabi mm Sol ,NR 00 NJ M53 1abal671-real rvc Pr 1501 boostnSo rte Cane nPnnenu. AS 66097 -Mol 65116021 Pi San France"". e 6000 Snor6ne C1 61e903, s. San Fnnmcr, On ACRES - mall AM6 653 Pe M er Eeni 6Sci lnn-Am 93MAS 1 are Eureka Read roarevily, CA 96661 Jim Kamm Willi" sel ln,library 2day TAT requested Sol ID Domil enTyq IB•Inwl amore VoIwW as warImbean N acme If wy.*eme, PR, Viol =Fo{ Vial FKoo.o��G ae 90-5"0 2! Poll ZFvl �J \i 1p L ZFOD a-Du6t 2{0< No ISM-Picabla War yTGo / Gfe</✓fI fCK/1146 6yeuom 11,191Me Cnam of Ccmy. 602 3 o< Dopygm C p00]-3009 Sol V6x i F�7 aL ."...m.A a Op REQUESTED SERVICES IJ aenel 9n spentPotable uum1 John Bum•Ida 911).00 ae 90-5"0 �J \i L water ae, a-Du6t No ISM-Picabla War OWOlner 6yeuom 11,191Me Cnam of Ccmy. me, as,, to be bi by In, term, an0ian eel loch at wwwmla .eopt cpnNnms Nor Dopygm C p00]-3009 Sol V6x F�7 ."...m.A a I in n,,.mn CHAIN OF CUSTODY I WEATHER WWon NJ board K-nom Hi OVESTEDBaavicE9 N6°..•I Po Lincoln wEast 6NbPRound b NJ06655 I isLabol rp D855 broadly AS SO Waal Mnuaeen Dlrve, Plwem.,R05@1'16W16E1<BOb MWemie CA Hery :7 W00 6nonine C161a 30], 6. Ben Frenorom CA 94W Inc318086659 _ rer Eng rnenryou of Bmnoe illAll016543 1 Sw flout, Road Suite 100 Bmevin,. CR 95661 Road wear 'epaauunnhorled, 2 day TAT requested Roieu Is 1925058E 2 pgld Es", wheal Rlf9ec Sampling ZIP Clyde 80033 mu 8mme: 9,27119 W'. 66 Oel u_w STIR No-Nenlisn SD. WN Bl.nmNIOEFAV5T1 sDzv Esme Bvsmeaaoay Bam rHa Rushes renewed after zpm or on wreki vellbe Randalla receivedt oen buamass aay. Pleeee 6letl us in vi of 'weekend Sol sional F JPC u M o u BampleTATy on, o y B.npro M p.enpllo^ hw tAs vmu NOTES eewm I mabro IT.namd, Tamp, IN ekl FmI� app a f 3 Zayi v..d g ZPAY O3 &0 002263763 05 OL i yon 3venor. v,,, v[ d qViabRost. 3Fa/ Vi✓rte <ou,✓f F01 V P zearodal STSporeTrap• e D -C°el John Myraloe 9/P¢919 1]90 BWBury °h 6C-6oJ -a•er BP None sok Was OC1Mr: By Whood,19 the Chain ofCvelWy,you agree lode bound by the ells and mnJAlons eel bno at way, emlaopkcon naav nuns Copyapbl W 200E Jjq�o9 Chirac, Phi CHAIN OF CUSTODY www. EMLII tole @ REQUESTED SERVICES (Uah..q filliell NJ so able Di smi A Menson. NJ 08053 usi 571195p K(y Phimalli 1501 what Nwesen Choy. Pnn.nN, As 85027 -Isom 551-nmzl a ab,CA WBB ShohimCt Sle ]O0. S San Fmntlw CA 9W00 - 10%10009050 Inc Acct 0 M ly ureaa W Iy, Be 951 scemeunmmmnny Sl day TAT requested 'ro•[1 to ID-zs¢saE] STO. Standard(DEFAULT) Rushes rec¢IVM after 2pm or ta v9¢h¢Otls. wlll be tOnsltbrpy a mwm Beee.: ween Pop eouD. s.mpunp u•n e11a1nye °ay e�mee me ren h0hm¢aa ear. f -� o IF CORE ti Dale S nme 9CE190900 SD -Came Business Oay Ruin PI¢¢¢al¢11 u91n etiv¢n[¢OI U is be _ weehenG enalVsls neetic ty t V NumMr. wN w eeand Houdey b _ _ d SmpM vnwlasram NOTES rdRD a BemgelD penlptlan Type (curve (sae urear. temp. rex. lettJay (Below) 1 a ¢ eIS Q 2. J IIPC,O //AG[ so eD N Ippy, J7 m➢IMI�WIN�IIII'��I61V' JOCA �L oo22e37e3 O1 211 di'eb/ Vi 6.eri /JOOfSa✓f at L fFo/ V,vvc F.vu..�a y Ono— w VCporeirap. T. rupee D. un Jonn Bilrzoten Swab 50 -Sou othabu No, PILlus Vital 0 Other By ynemul p this Cham o(Dusady you aymto be Lound by the See ARE mrshans authors s iveavhmlaepe.vnmhermh The Copyrlphl m 2002-x009 EML. PON G/-7 a..aanls ni. aaam e..1a,. dah CHAIN OF CUSTODY wWw EMLfr com Bi e St One A Notion, N 66l llet bn. NJ 3020Imestn udeE 1888 6 me PZ 1501 West Knudsen ems, PhOr PZ 8589 5)BOOj 651 Mewl A SO' Ful CA 68085nanineP An J03. 5 Sen inncem. CP Al ' (866)688.665) Pauper EnBlneal d 5wnce Inc- Acct 036543 120."ten Willing 19-2586852 80833 Card Tlmx L9/1909 OD SOmpb ID I Cnor"i ne 180, RouWIb, CA 93661 fail Inmeelanx.2 day TAT requested NO - and Beane.. Day modencyleved Me e ED- Rame Deamese Davmtm I+lesseelee�s }�A?5 /.vi.Icc c fes,.. -o i4 2DM ob oS OL 07 SVBAO/ 1/iNYc 9ASf iCgfiS�4F Fe/oL Viu vc l�l// Fob<iuq S Fva JI NOTES (Time Of day, Temp, RK el REQUESTED SERVICES (in'BCA") AT. Spore nap. tape u -es Jpnn Bdu,nker W27RI1911 SO SaoSend Sofail It Paul water 8 Bul aR- Non.Peleme wale 0. Cither By submitting this Chain 0 Custody. hill 19111 Ic 4 pound by the term. and COrdenl aelmy an f,s Annual wait dill pYnl9n102002-2009 Eirt V6K 7�17 e,..2a„e ae.i.em,tman,ta.a tiff eurofins i EMLab P&K Report for: Karen Willing Partner Engineering & Science Inc. NorCal 1544 Eureka Road, Suite 180 Roseville, CA 95661 Regarding: Project: 19-258685.2; Wheat Ridge, CO EML ID: 2263763 Approved by: Approved Signatory Noah Lazarte Dates of Analysis: Asbestos PLM: 09-30-2019 and 10-01-2019 Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM -AS -S-1267) All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1 % asbestos concentration can be provided when requested. Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor. EMLab P&K, LLC EMLab ID: 2263763, Page 1 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 1C01, Ceiling Texture Total Samples Submitted: 81 Total Samples Analyzed: 80 Total Samples with Layer Asbestos Content> 1%: 59 Lab ID -Version$: 10765072-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: ICO2, Ceiling Texture Lab ID -Version$: 10765073-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: IC03, Ceiling Texture Lab ID -Version$: 10765074-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: IC04, Ceiling Texture Lab ID -Version$: 10765075-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sam IeCom ositeHomo enei Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 2 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: IC05, Ceiling Texture Lab ID -Version$: 10765076-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: IC06, Ceiling Texture Lab ID -Version$: 10765077-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: IC07, Ceiling Texture Lab ID -Version$: 10765078-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 1W01, Wall Compound Lab ID -Version$: 10765079-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 3 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: IW02, Wall Compound Lab ID -Version$: 10765080-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: IW03, Wall Compound Lab ID -Version$: 10765081-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: IW04, Wall Compound Lab ID -Version$: 10765082-1 Sample Layers Asbestos Content Beige Floor Tile ND Multicolored Mastic ND Sample Composite Homogeneity: Poor Location: IW05, Wall Compound Lab ID -Version$: 10765083-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 4 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: IW06, Wall Compound Lab ID -Version$: 10765084-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: IW07, Wall Compound Lab ID -Version$: 10765085-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 1VBA01, Vinyl Base Adhesive Lab ID -Version$: 10765086-1 Sample Layers Asbestos Content White Baseboard ND Brown Mastic ND Sample Composite Homogeneity: Moderate Location: IVBA02, Vinyl Base Adhesive Lab ID -Version$: 10765087-1 Sample Layers Asbestos Content Gray Baseboard ND Cream Mastic ND Sample Composite Homogeneity: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 5 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 1F01, Vinyl Flooring Lab ID -Version$: 10765088-1 Sample Layers Asbestos Content Brown Sheet Flooring ND Sample Composite Homogeneity: Good Location: 1F02, Vinyl Flooring Lab ID -Version$: 10765089-1 Sample Layers Asbestos Content Gray Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Composite Non -Asbestos Content: 20% Cellulose 10% Glass Fibers Sample ComositeHomogeneity: Moderate Location: 1F03, Vinyl Flooring Lab ID -Version$: 10765090-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 1F04, Vinyl Flooring Lab ID -Version$: 10765091-1 Sample Layers Asbestos Content Gray Sheet Flooring with Fibrous Backing ND Composite Non -Asbestos Content: 20% Cellulose 10% Glass Fibers Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 6 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 2C01, Ceiling Texture Lab ID -Version$: 10765092-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 2CO2, Ceiling Texture Lab ID -Version$: 10765093-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: 2CO3, Ceiling Texture Lab ID -Version$: 10765094-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 2C04, Ceiling Texture Lab ID -Version$: 10765095-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 7 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 2C05, Ceiling Texture Lab ID -Version$: 10765096-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 2C06, Ceiling Texture Lab ID -Version$: 10765097-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: 2C07, Ceiling Texture Lab ID -Version$: 10765098-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 2W01, Wall Compound Lab ID -Version$: 10765099-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 8 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 2W02, Wall Compound Lab ID -Version$: 10765100-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 2W03, Wall Compound Lab ID -Version$: 10765101-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 2W04, Wall Compound Lab ID -Version$: 10765102-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 2W05, Wall Compound Lab ID -Version$: 10765103-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 9 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 2W06, Wall Compound Lab ID -Version$: 10765104-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 2W07, Wall Compound Lab ID -Version$: 10765105-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 2VBA01, Vinyl Base Adhesive Lab ID -Version$: 10765106-1 Sample Layers Asbestos Content Beige Baseboard ND Cream Mastic ND Off -White Leveling Compound 2% Chrysotile Sample ComositeHomogeneity: Poor Location: 2VBA02, Vinyl Base Adhesive Lab ID -Version$: 10765107-1 Sample Layers Asbestos Content Beige Baseboard ND Cream Mastic ND Sample Composite Homogeneity: Moderate The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 10 of 21 EuroTms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 2F01, Vinyl Flooring Lab ID -Version$: 10765108-1 Sample Layers Asbestos Content Beige Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Composite Non -Asbestos Content: 20% Cellulose 10% Glass Fibers Sample Composite Homogeneity: Moderate Location: 2F02, Vinyl Flooring Lab ID -Version$: 10765109-1 Sample Layers Asbestos Content Beige Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Composite Non -Asbestos Content: 20% Cellulose 10% Glass Fibers Sample Composite Homogeneity: Moderate Location: 2F03, Vinyl Flooring Lab ID -Version$: 10765110-1 Sample Layers Asbestos Content Brown Sheet Flooring ND Semi -Transparent Mastic ND Sample ComositeHomogeneity: Moderate Location: 3C01, Ceiling Texture Lab ID -Version$: 10765112-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 11 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 3CO2, Ceiling Texture Lab ID -Version$: 10765113-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 3CO3, Ceiling Texture Lab ID -Version$: 10765114-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: 3C04, Ceiling Texture Lab ID -Version$: 10765115-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 3C05, Ceiling Texture Lab ID -Version$: 10765116-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 12 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 3C06, Ceiling Texture Lab ID -Version$: 10765117-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Composite Homogeneity: Good Location: 3C07, Ceiling Texture Lab ID -Version$: 10765118-1 Sample Layers Asbestos Content White Ceiling Texture with Paint 5% Chrysotile Sample Comosite Homogeneity: Good Location: 3W01, Wall Compound Lab ID -Version$: 10765119-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 3W02, Wall Compound Lab ID -Version$: 10765120-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 13 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 3W03, Wall Compound Lab ID -Version$: 10765121-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 3W04, Wall Compound Lab ID -Version$: 10765122-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 3W05, Wall Compound Lab ID -Version$: 10765123-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 3W06, Wall Compound Lab ID -Version$: 10765124-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 14 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 3W07, Wall Compound Lab ID -Version$: 10765125-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 3VBA01, Vinyl Base Adhesive Lab ID -Version$: 10765126-1 Sample Layers Asbestos Content Off -White Baseboard ND Cream Mastic ND Off -White Compound 2% Chrysotile Sample ComositeHomogeneity: Poor Location: 3VBA02, Vinyl Base Adhesive Lab ID -Version$: 10765127-1 Sample Layers Asbestos Content Beige Baseboard ND Cream Mastic ND Sample ComositeHomogeneity: Poor Location: 3F01, Vinyl Flooring Lab ID -Version$: 10765128-1 Sample Layers Asbestos Content Brown Sheet Flooring ND Semi -Transparent Mastic ND Brown Wood ND Composite Non -Asbestos Content: 10% Cellulose Sample ComositeHomogeneity: Poor The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 15 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 3F02, Vinyl Flooring Lab ID -Version$: 10765129-1 Sample Layers Asbestos Content Brown Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Beige Sheet Flooring with Fibrous Backing ND Composite Non -Asbestos Content: 30% Cellulose 10% Glass Fibers Sample ComositeHomogeneity: Poor Location: 4W01, Wall Compound Lab ID -Version$: 10765130-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 4W02, Wall Compound Lab ID -Version$: 10765131-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 4W03, Wall Compound Lab ID -Version$: 10765132-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 16 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 4W04, Wall Compound Lab ID -Version$: 10765133-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 4W05, Wall Compound Lab ID -Version$: 10765134-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 4W06, Wall Compound Lab ID -Version$: 10765135-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 4W07, Wall Compound Lab ID -Version$: 10765136-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 17 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 4VBA01, Vinyl Base Adhesive Lab ID -Version$: 10765137-1 Sample Layers Asbestos Content Beige Baseboard ND Cream Mastic ND Sample Composite Homogeneity: Moderate Location: 4VBA02, Vinyl Base Adhesive Lab ID -Version$: 10765138-1 Sample Layers Asbestos Content Gray Baseboard ND Cream Mastic ND Sample ComositeHomogeneity: Moderate Location: 4F01, Vinyl Flooring Lab ID -Version$: 10765139-1 Sample Layers Asbestos Content Brown Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Beige Sheet Flooring with Fibrous Backing ND Composite Non -Asbestos Content: 30% Cellulose 10% Glass Fibers Sample ComositeHomogeneity: Poor Location: 4F02, Vinyl Flooring Lab ID -Version$: 10765140-1 Sample Layers Asbestos Content Brown Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Beige Sheet Flooring with Fibrous Backing ND Semi -Transparent Mastic ND Composite Non -Asbestos Content: 30% Cellulose 10% Glass Fibers Sample ComositeHomo enei Poor The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 18 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 4F03, Vinyl Flooring Lab ID -Version$: 10765141-1 Sample Layers Asbestos Content Brown Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Composite Non -Asbestos Content: 20% Cellulose 10% Glass Fibers Sample Composite Homogeneity: Moderate Location: 5W01, Wall Compound Lab ID -Version$: 10765142-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 5W02, Wall Compound Lab ID -Version$: 10765143-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 5W03, Wall Compound Lab ID -Version$: 10765144-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 19 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 5W04, Wall Compound Lab ID -Version$: 10765145-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 5W05, Wall Compound Lab ID -Version$: 10765146-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good Location: 5W06, Wall Compound Lab ID -Version$: 10765147-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Composite Homogeneity: Good Location: 5W07, Wall Compound Lab ID -Version$: 10765148-1 Sample Layers Asbestos Content Off -White Compound with Paint 2% Chrysotile Sample Comosite Homogeneity: Good The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 20 of 21 Eurorms EMLab P&K 4955 Yarrow Street, Arvada, CO 80002 (800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Partner Engineering & Science Inc. NorCal C/O: Karen Willing Date of Receipt: 09-27-2019 Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019 ASBESTOS PLM REPORT Location: 5VBA01, Vinyl Base Adhesive Lab ID -Version$: 10765149-1 Sample Layers Asbestos Content Off -White Baseboard ND Cream Mastic ND Off -White Compound 2% Chrysotile Sample Composite Homogeneity: Poor Location: 5VBA02, Vinyl Base Adhesive Lab ID -Version$: 10765150-1 Sample Layers Asbestos Content Off -White Baseboard ND Cream Mastic ND Sample Composite Homogeneity: Moderate Location: 5F01, Vinyl Flooring Lab ID -Version$: 10765151-1 Sample Layers Asbestos Content Tan Sheet Flooring with Fibrous Backing ND Yellow Mastic ND Composite Non -Asbestos Content: 20% Cellulose 10% Glass Fibers Sample ComositeHomogeneity: Moderate Location: 5F02, Vinyl Flooring Lab ID -Version$: 10765152-1 Sample Layers Asbestos Content Brown Sheet Flooring ND Semi -Transparent Mastic ND Gray Leveling Compound ND Yellow Mastic ND Sample ComositeHomogeneity: Poor The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification. $ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x". EMLab P&K, LLC EMLab ID: 2263763, Page 21 of 21 No Site Results P6C 1 Calibrate Positive 1 mg/cm2 0.1 2 Calibrate Positive 1 mg/cm2 0.1 3 Calibrate Positive 1 mg/cm2 0.1 4 923506 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 5 923506 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 6 923506 Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 7 923506 Rm. 01 C Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 S 923506 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 9 923506 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 10 923506 Rm. 02 A Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 11 923506 Rm. 02 A Door Casing Wood Black Intact Negative 0.02 mg/cm2 0.04 12 923506 Rm. 02 A Door Wood Stained Intact Negative 0.03 mg/cm2 0.05 13 923506 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 14 923506 Rm. 03 A Closet Door Wood Brown Intact Negative 0 mg/cm2 0.02 15 923506 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 16 923506 Rm. 04 D Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 17 923506 Rm. 04 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 16 923506 Rm. 04 D Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 19 923506 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 20 923506 Rm. 05 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 21 923506 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 22 923506 Rm. 05 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 23 923511 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 24 923511 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 25 923511 Rm. 01 D Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 26 923511 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 27 923511 Rm. 02 A Door Casing Wood Brown Intact Negative 0 mg/cm2 0.02 26 923511 Rm. 02 A Door Wood Brown Intact Negative 0 mg/cm2 0.02 29 923511 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 30 923511 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 31 923511 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 32 923511 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 33 923511 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 34 923511 Rm. 05 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 35 923511 Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 36 923519 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 37 923519 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 36 923519 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 39 923519 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 40 923519 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 41 923519 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 42 923519 Rm. 03 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 43 923519 Rm. 03 D Wall Radiator Metal White Intact Negative 0.02 mg/cm2 0.1 44 923519 Rm. 03 D Door Jamb Wood Brown Intact Negative 0.2 mg/cm2 0.22 45 923519 Rm. 03 D Door Wood Brown Intact Negative 0 mg/cm2 0.02 46 923519 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 47 923519 Rm. 04 B Wall Drywall White Intact Negative 0.05 mg/cm2 0.9 48 923519 Rm. 04 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 49 923520 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 50 923520 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 51 923520 Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 52 923520 Rm. 01 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 53 923520 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 54 923520 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 55923520 Rm. 02 D Door Jamb Wood White Intact Negative 0.03 mg/cm2 0.05 56 923520 Rm. 02 D Door Wood White Intact Negative 0 mg/cm2 0.02 57 923520 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 56923520 Rm. 03 A Door Jamb Wood White Intact Negative 0.12 mg/cm2 0.22 59 923520 Rm. 03 A Door Wood White Intact Negative 0 mg/cm2 0.02 60 923520 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 61 923520 Rm. 04 C Wall Radiator Metal White Intact Negative 0.01 mg/cm2 0.06 62 923520 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 63 923520 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 64 9235 Laundry Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 65 9235 Laundry Rm. 01 A Wall Drywall Green Intact Negative 0 mg/cm2 0.02 66 9235 Laundry Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 67 9235 Laundry Rm. 01 A Door Casing Wood Brown Intact Negative 0.01 mg/cm2 0.03 66 9235 Laundry Rm. 01 A Door Wood Brown Intact Negative 0.02 mg/cm2 0.06 69 9235 Office Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 70 9235 Office Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 71 9235 Office Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 72 9235 Office Rm. 01 C Cabinet Door Wood Stained Intact Negative 0.03 mg/cm2 0.06 73 9235 Office Rm. 01 A Wall Drywall Tan Intact Negative 0 mg/cm2 0.02 74 9235 Office Rm. 01 B Wall Drywall Tan Intact Negative 0 mg/cm2 0.02 759235 Office Rm. 01 B Wall Chair Rail Wood White Intact Negative 0Mg/cm2 0.02 76 9235 Office Rm. 03 A Wall Drywall Tan Intact Negative 0 mg/cm2 0.02 77 9235 Office Rm. 03 D Door Jamb Wood Stained Intact Negative 0.13 mg/cm2 0.14 76 9235 Office Rm. 03 D Door Wood Stained Intact Negative 0 mg/cm2 0.02 79 9235 Office Rm. 03 D Closet Door Wood White Intact Negative 0 mg/cm2 0.02 SO 9235 Office Rm. 03 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 81 9235 Office Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 82 9235 Office Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 83 9235 Office Rm. 04 D Cabinet Frame Wood Stained Intact Negative 0.05 mg/cm2 0.09 84 9235 Office Rm. 05 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 85 9235 Office Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 86 926501 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 87 926501 Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 SS 926501 Rm. 02 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 89 926501 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 90 926501 Rm. 02 A Door Casing Wood Stained Intact Negative 0.04 mg/cm2 0.06 91 926501 Rm. 02 A Door Wood Stained Intact Negative 0.05 mg/cm2 0.14 92 926501 Rm. 03 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 93 926501 Rm. 03 C Wall Radiator Metal White Intact Negative 0.04 mg/cm2 0.64 94 926501 Rm. 03 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 95 926501 Rm. 04 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 96 926501 Rm. 04 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 97 926501 Rm. 04 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 98 926501 Rm. 04 B Door Casing Wood White Intact Negative 0 mg/Cm2 0.02 99 926501 Rm. 04 B Door Wood Brown Intact Negative 0 mg/Cm2 0.02 100 926504 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 101 926504 Rm. 01 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 102 926504 Rm. 01 D Wall Baseboard Wood White Intact Negative 0.01 mg/Cm2 0.04 103 926504 Rm. 01 B Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 104 926504 Rm. 01 B Cabinet Frame Wood White Intact Negative 0.24 mg/Cm2 0.23 105 926504 Rm. 02 B Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 106 926504 Rm. 02 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 107 926504 Rm. 02 D Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 108 926504 Rm. 03 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 109 926504 Rm. 03 B Door Jamb Wood Stained Intact Negative 0.16 mg/Cm2 0.18 110 926504 Rm. 03 B Door Wood Stained Intact Negative 0 mg/Cm2 0.02 111 926504 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 112 926504 Rm. 04 A Door Casing Wood White Intact Negative 0 mg/Cm2 0.02 113 926504 Rm. 04 A Door Metal White Intact Negative 0 mg/Cm2 0.02 114 926506 Rm. 01 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 115 926506 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 116 926506 Rm. 01 B Wall Radiator Metal White Intact Negative 0.01 mg/Cm2 0.03 117 926506 Rm. 02 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 118 926506 Rm. 02 D Door Jamb Metal White Intact Negative 0.05 mg/Cm2 0.08 119 926506 Rm. 02 D Door Metal White Intact Negative 0 mg/Cm2 0.02 120 926506 Rm. 02 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 121 926506 Rm. 03 A Door Jamb Wood White Intact Negative 0.07 mg/Cm2 0.09 122 926506 Rm. 03 A Door Wood White Intact Negative 0.05 mg/Cm2 0.07 123 926506 Rm. 04 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 124 926506 Rm. 04 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 125 926506 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 126 926506 Rm. 04 B Door Jamb Wood White Intact Negative 0.06 mg/Cm2 0.09 127 926506 Rm. 04 B Door Wood White Intact Negative 0 mg/Cm2 0.02 128 926506 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 129 926506 Rm. 05 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 130 926506 Rm. 05 A Door Casing Wood White Intact Negative 0 mg/Cm2 0.02 131 926506 Rm. 05 A Door Wood White Intact Negative 0 mg/Cm2 0.02 132 926512 Rm. 01 D Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 133 926512 Rm. 01 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 134 926512 Rm. 01 D Wall Shelf Wood White Intact Negative 0.02 mg/Cm2 0.07 135 926512 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 136 926512 Rm. 02 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 137 926512 Rm. 02 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 138 926512 Rm. 02 D Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 139 926512 Rm. 02 D Door Casing Wood Brown Intact Negative 0.28 mg/Cm2 0.22 140 926512 Rm. 02 D Door Wood Brown Intact Negative 0 mg/Cm2 0.02 141 926512 Rm. 03 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 142 926512 Rm. 03 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 143 926512 Rm. 03 B Closet Door Wood Brown Intact Negative 0.08 mg/Cm2 0.1 144 926512 Rm. 03 B Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 145 926512 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 146 926512 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 147 926512 Rm. 04 A Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 148 926512 Rm. 04 A Door Casing Wood Brown Intact Negative 0 mg/Cm2 0.02 149 926512 Rm. 04 A Door Wood Brown Intact Negative 0.01 mg/Cm2 0.03 150 926513 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 151 926513 Rm. 01 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 152 926513 Rm. 01 D Cabinet Door Wood White Intact Negative 0.01 mg/Cm2 0.03 153 926513 Rm. 01 D Cabinet Frame Wood White Intact Negative 0 mg/Cm2 0.02 154 926513 Rm. 02 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 155 926513 Rm. 02 A Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 156 926513 Rm. 02 A Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 157 926513 Rm. 03 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 158 926513 Rm. 03 B Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 159 926513 Rm. 04 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 160 926513 Rm. 04 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 161 926513 Rm. 04 B Wall Radiator Metal White Intact Negative 0.01 mg/Cm2 0.05 162 926513 Rm. 04 D Cabinet Door Wood White Intact Negative 0.01 mg/Cm2 0.04 163 926513 Rm. 04 D Cabinet Frame Wood White Intact Negative 0.28 mg/Cm2 0.2 164 926518 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 165 926518 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 166 926518 Rm. 01 B Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 167 926518 Rm. 01 B Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 168 926518 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 169 926518 Rm. 02 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 170 926518 Rm. 02 A Wall Shelf Wood White Intact Negative 0 mg/Cm2 0.02 171 926518 Rm. 03 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 172 926518 Rm. 03 B Cabinet Door Wood White Intact Negative 0.01 mg/Cm2 0.03 173 926518 Rm. 03 B Cabinet Frame Wood White Intact Negative 0 mg/Cm2 0.02 174 926518 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 175 926518 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 176 926518 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 177 926518 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 178 926518 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 179 926518 Rm. 05 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 180 926518 Rm. 05 A Door Casing Wood Stained Intact Negative 0.01 mg/Cm2 0.05 181 926518 Rm. 05 A Door Wood Stained Intact Negative 0.02 mg/Cm2 0.07 182 9265 Laundry Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 183 9265 Laundry Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 184 9265 Laundry Rm. 01 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 185 9265 Laundry Rm. 01 A Door Jamb Wood Brown Intact Negative 0.01 mg/Cm2 0.03 186 9265 Laundry Rm. 01 A Door Wood Brown Intact Negative 0.1 mg/Cm2 0.21 187 9265 Laundry Rm. 01 B Wall Shelf Wood White Intact Negative 0 mg/Cm2 0.02 188 9295101 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 189 9295101 Rm. 02 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 190 9295101 Rm. 02 A Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 191 9295101 Rm. 02 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 192 9295101 Rm. 02 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 193 9295101 Rm. 02 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 194 9295101 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 195 9295101 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 196 9295101 Rm. 03 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 197 9295101 Rm. 03 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 198 9295101 Rm. 03 B Cabinet Door Wood White Intact Negative 0.27 mg/Cm2 0.2 199 9295101 Rm. 05 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 200 9295101 Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 201 9295101 Rm. 05 C Door Jamb Wood Brown Intact Negative 0.11 mg/Cm2 0.13 202 9295101 Rm. 05 B Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.03 203 9295102 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 204 9295102 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 205 9295102 Rm. 01 B Cabinet Door Wood White Intact Negative 0.3 mg/Cm2 0.25 206 9295102 Rm. 01 C Wall Shelf Wood White Intact Negative 0 mg/Cm2 0.02 207 9295102 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 208 9295102 Rm. 03 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 209 9295102 Rm. 03 A Door Jamb Wood Brown Intact Negative 0.11 mg/Cm2 0.14 210 9295102 Rm. 03 A Door Wood Brown Intact Negative 0 mg/Cm2 0.02 211 9295102 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 212 9295102 Rm. 03 A Closet Door Metal White Intact Negative 0 mg/Cm2 0.02 213 9295102 Rm. 04 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 214 9295102 Rm. 04 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 215 9295102 Rm. 04 B Wall Radiator Metal White Intact Negative 0.06 mg/Cm2 0.11 216 9295102 Rm. 04 B Door Casing Wood Brown Intact Negative 0.09 mg/Cm2 0.1 217 9295103 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 218 9295103 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 219 9295103 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 220 9295103 Rm. 01 B Wall Radiator Metal White Intact Negative 0.02 mg/Cm2 0.12 221 9295103 Rm. 02 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 222 9295103 Rm. 02 A Closet Door Metal White Intact Negative 0 mg/Cm2 0.02 223 9295103 Rm. 02 A Closet Shelf Wood White Intact Negative 0.01 mg/Cm2 0.04 224 9295103 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 225 9295103 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 226 9295103 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 227 9295103 Rm. 05 B Cabinet Door Wood Stained Intact Negative 0.4 mg/Cm2 0.3 228 9295103 Rm. 05 C Door Jamb Wood Brown Intact Negative 0.4 mg/Cm2 0.4 229 9295103 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 230 9295103 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 231 9295107 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 232 9295107 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 233 9295107 Rm. 01 A Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 234 9295107 Rm. 02 D Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 235 9295107 Rm. 02 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 236 9295107 Rm. 02 D Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 237 9295107 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 238 9295107 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 239 9295107 Rm. 04 A Door Jamb Wood Brown Intact Negative 0.16 mg/Cm2 0.17 240 9295107 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 241 9295107 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 242 9295107 Rm. 05 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 243 9295107 Rm. 05 A Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 244 9295107 Rm. 05 D Cabinet Frame Wood Stained Intact Negative 0 mg/Cm2 0.02 245 9295205 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 246 9295205 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 247 9295205 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 248 9295205 Rm. 01 A Door Jamb Wood Brown Intact Negative 0 mg/Cm2 0.02 249 9295205 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 250 9295205 Rm. 02 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 251 9295205 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 252 9295205 Rm. 03 D Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 253 9295205 Rm. 03 D Wall Drywall White Intact Negative 0.01 mg/Cm2 0.02 2549295205 Rm. 03 D Cabinet Door Wood White Intact Negative 0.3 mg/Cm2 0.22 255 9295205 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 256 9295205 Rm. 04 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 257 9295205 Rm. 04 C Wall Radiator Metal White Intact Negative -0.08 mg/Cm2 0.93 2589295205 Rm. 04 C Window Sill Wood White Intact Negative 0.01 mg/Cm2 0.02 259 9295205 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 260 9295 Laundry Rm. 01 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 261 9295 Laundry Rm. 01 C Wall Shelf Wood White Intact Negative 0 mg/Cm2 0.02 262 Calibrate Positive 1 mg/Cm2 0.1 263 Calibrate Positive 1 mg/Cm2 0.1 264 Calibrate Positive 1 mg/Cm2 0.1 265 932508 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 266 932508 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 267 932508 Rm. 01 A Cabinet Frame Wood White Intact Negative 0.4 mg/Cm2 0.4 268 932508 Rm. 02 B Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 269 932508 Rm. 02 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 270932508 Rm. 02 B Wall Radiator Metal White Intact Negative 0.01 mg/Cm2 0.06 271 932508 Rm. 02 A Door Wood Brown Intact Negative 0.21 mg/Cm2 0.15 272 932508 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 273 932508 Rm. 03 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 274 932508 Rm. 03 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 275 932508 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 276 932508 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 277 932508 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 278932508 Rm. 04 A Door Jamb Wood White Intact Negative 0.19 mg/Cm2 0.19 279 932508 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 280 932508 Rm. 05 B Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 281 932508 Rm. 05 D Closet Door Wood White Intact Negative 0 mg/Cm2 0.02 282 932508 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 283 932508 Rm. 05 C Door Jamb Wood White Intact Negative 0 mg/Cm2 0.02 284 932517 Rm. 01 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 285 932517 Rm. 01 C Cabinet Door Wood White Intact Negative 0.07 mg/Cm2 0.18 286 932517 Rm. 02 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 287 932517 Rm. 02 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 288 932517 Rm. 02 B Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 289 932517 Rm. 02 A Door Casing Wood Brown Intact Negative 0 mg/Cm2 0.02 290 932517 Rm. 03 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 291 932517 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 292 932517 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 293 932517 Rm. 03 A Door Jamb Wood Stained Intact Negative 0.27 mg/Cm2 0.21 294 932517 Rm. 03 A Door Wood Stained Intact Negative 0 mg/Cm2 0.02 295 932517 Rm. 05 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 296 932517 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 297 932517 Rm. 05 B Cabinet Frame Wood White Intact Negative 0.26 mg/Cm2 0.21 298 932515 Rm. 01 A Ceiling Drywall White Intact Negative 0.02 mg/Cm2 0.09 299 932518 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 300 932518 Rm. 01 A Cabinet Frame Wood White Intact Negative 0.18 mg/Cm2 0.23 301 932518 Rm. 01 A Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.03 302 932518 Rm. 02 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 303 932518 Rm. 02 B Wall Radiator Metal White Intact Negative 0.03 mg/Cm2 0.11 304 932518 Rm. 02 A Door Casing Wood Stained Intact Negative 0 mg/Cm2 0.02 305 932518 Rm. 02 A Door Wood Stained Intact Negative 0.17 mg/Cm2 0.17 306 932518 Rm. 03 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 307 932518 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 308 932518 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 309 932518 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 310 932518 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 311 932518 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 312 932518 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 313 932518 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 314 932520 Rm. 01 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 315 932520 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 316 932520 Rm. 01 A Door Jamb Wood Brown Intact Negative 0.01 mg/Cm2 0.05 317 932520 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 318 932520 Rm. 01 A Cabinet Frame Wood White Intact Negative 0 mg/Cm2 0.02 319 932520 Rm. 04 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 320 932520 Rm. 04 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 321 932520 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 322 932520 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 323 932520 Rm. 04 A Door Jamb Wood Stained Intact Negative 0.28 mg/Cm2 0.22 324 932520 Rm. 04 A Door Wood Stained Intact Negative 0 mg/Cm2 0.02 325 932520 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 326 932520 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 327 932520 Rm. 05 B Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 328 932520 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 329 932520 Rm. 12 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 330 932520 Rm. 12 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 331 932520 Rm. 12 A Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 332 932520 Rm. 02 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 333 932520 Rm. 02 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 334 932520 Rm. 02 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 335 932520 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 336 932520 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 337 932520 Rm. 03 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 338932520 Rm. 03 A Door Jamb Wood Stained Intact Negative 0.21 mg/Cm2 0.17 339 932520 Rm. 03 A Door Wood Stained Intact Negative 0 mg/Cm2 0.02 340 932520 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 341 932520 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 342 932520 Rm. 03 B Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 343 932520 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 344 932520 Rm. 04 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 345 932520 Rm. 04 C Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 346 932520 Rm. 04 D Door Casing Wood Stained Intact Negative 0.4 mg/Cm2 0.3 347 932520 Rm. 04 D Door Wood Stained Intact Negative 0 mg/Cm2 0.02 348 935503 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 349 935503 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 350 935503 Rm. 01 A Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 351 935503 Rm. 02 A Door Casing Wood Brown Intact Negative 0 mg/Cm2 0.02 352 935503 Rm. 02 A Door Wood Brown Intact Negative 0.03 mg/Cm2 0.07 353 935503 Rm. 02 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 354 935503 Rm. 02 B Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 355 935503 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 356 935503 Rm. 03 A Wall Drywall White Intact Negative -0.13 mg/Cm2 0.81 357 935503 Rm. 03 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 358 935503 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 359 935503 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 360 935503 Rm. 03 A Closet Jamb Wood White Intact Negative 0 mg/Cm2 0.02 361 935503 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 362 935503 Rm. 03 A Door Jamb Wood White Intact Negative 0.4 mg/Cm2 0.5 363 935503 Rm. 04 A Door Casing Wood White Intact Negative 0.28 mg/Cm2 0.43 364 935503 Rm. 04 A Closet Jamb Wood White Intact Negative 0 mg/Cm2 0.02 365 935503 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 366 935503 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 367 935503 Rm. 05 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 368 935503 Rm. 05 D Closet Door Wood White Intact Negative 0 mg/Cm2 0.02 369 935503 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 370 935503 Rm. 05 B Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 371 935503 Rm. 05 C Door Jamb Wood White Intact Negative 0.17 mg/Cm2 0.2 372 935503 Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 373 935506 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 374 935506 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 375 935506 Rm. 01 A Door Casing Wood Stained Intact Negative 0.4 mg/Cm2 0.3 376 935506 Rm. 01 A Door Wood Stained Intact Negative 0.08 mg/Cm2 0.1 377 935506 Rm. 02 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 378 935506 Rm. 02 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 379 935506 Rm. 03 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 380 935506 Rm. 03 D Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 381 935506 Rm. 03 D Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 382 935506 Rm. 03 B Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 383 935506 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 384 935506 Rm. 03 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 385 935506 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 386 935506 Rm. 03 A Closet Shelf Wood White Intact Negative 0.02 mg/Cm2 0.09 387 935506 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 388 935506 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 389 935506 Rm. 05 B Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 390 935510 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 391 935510 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 392 935510 Rm. 01 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 393 935510 Rm. 01 B Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 394 935510 Rm. 01 B Cabinet Frame Wood Stained Intact Negative 0 mg/Cm2 0.02 395 935510 Rm. 02 C Ceiling Drywall Stained Intact Negative 0 mg/Cm2 0.02 396 935510 Rm. 02 C Wall Drywall Stained Intact Negative 0 mg/Cm2 0.02 397 935510 Rm. 02 C Door Casing Wood Stained Intact Negative 0 mg/Cm2 0.02 398 935510 Rm. 03 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 399 935510 Rm. 03 B Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 400 935510 Rm. 03 B Door Wood Stained Intact Negative 0.26 mg/Cm2 0.2 401 935510 Rm. 03 B Door Wood Stained Intact Negative 0.11 mg/Cm2 0.12 402 935510 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 403 935510 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 404 935510 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 405 935510 Rm. 05 D Wall Drywall White Intact Negative 0 mg/Cm2 0.02 406 935510 Rm. 05 D Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 407 935510 Rm. 05 D Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 408 935513 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 409 935513 Rm. 01 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 410 935513 Rm. 01 A Cabinet Frame Wood White Intact Negative 0.4 mg/Cm2 0.3 411 935513 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 412 935513 Rm. 02 C Door Casing Wood White Intact Negative 0 mg/Cm2 0.02 413 935513 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 414 935513 Rm. 04 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 415 935513 Rm. 04 A Door Jamb Wood Stained Intact Negative 0.23 mg/Cm2 0.18 416 935513 Rm. 04 A Door Wood Stained Intact Negative 0 mg/Cm2 0.02 417 935513 Rm. 04 C Wall Radiator Metal White Intact Negative 0 mg/Cm2 0.02 418 935513 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 419 935513 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 420 935513 Rm. 05 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 421 935513 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 422 935513 Rm. 05 B Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 423 935513 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 424 935521 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 425 935521 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 426 935521 Rm. 04 C Wall Drywall White Intact Negative 0 mg/Cm2 0.02 427 935521 Rm. 04 C Wall Baseboard Wood White Intact Negative 0 mg/Cm2 0.02 428 935521 Rm. 04 C Door Jamb Wood White Intact Negative 0 mg/Cm2 0.02 429 935521 Rm. 04 C Door Wood White Intact Negative 0 mg/Cm2 0.02 430 935521 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 431 935521 Rm. 05 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 432 935521 Rm. 05 B Cabinet Frame Wood Stained Intact Negative 0 mg/Cm2 0.02 433 935521 Rm. 05 B Cabinet Door Wood Stained Intact Negative 0 mg/Cm2 0.02 434 935521 Rm. 07 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 435 935521 Rm. 07 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 436 935521 Rm. 07 A Cabinet Door Wood White Intact Negative 0 mg/Cm2 0.02 437 935521 Rm. 07 B Door Jamb Wood Brown Intact Negative 0.4 mg/Cm2 0.2 438935521 Rm. 07 B Door Wood Stained Intact Negative 0.26 mg/Cm2 0.25 439 935521 Rm. 09 A Ceiling Drywall White Intact Negative 0 mg/Cm2 0.02 440 935521 Rm. 09 A Wall Drywall White Intact Negative 0 mg/Cm2 0.02 441 935521 Rm. 09 B Wall Drywall White Intact Negative 0 mg/Cm2 0.02 442 935521 Rm. 09 B Closet Shelf Wood White Intact Negative 0 mg/Cm2 0.02 443 935521 Rm. 09 C Window Sill Wood White Intact Negative 0 mg/Cm2 0.02 444 935521 Rm. 09 C Window Casing Wood White Intact Negative 0 mg/Cm2 0.02 445 935521 Rm. 09 D Door Jamb Wood White Intact Negative 0 mg/Cm2 0.02 446 Calibrate Positive 1 mg/Cm2 0.1 447 Calibrate Positive 1 mg/Cm2 0.1 448 Calibrate Positive 1.1 mg/Cm2 0.1 APPENDIX B: SAMPLE LOCATIONS PARTNER Side C Rm 4 Bath RM 5 Rut 3 Bedroom Bedroom 1VBA02 SideSide �j -B 1W03 1CO3 " Rm 2 Living Rut 1 Kitchen 1 F02 Unit 9235-06 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 4 Bath RM 5 Rut 3 Bedroom Bedroom Side 1W07 Side B Rm 2 1C07 Living Rut 1 Kitchen Unit 9235-11 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 2 1co5 Bath Rm 3 Bedroom Side Side 1W05 D 1F04 Rm 1 Kitchen R1114 1C04 Living Unit 9235=19 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 3 2 Bath Rm 4 Bedroom Bedroom Side 1W06 Side 1 C0 Rm 1 Rm 5 Kitchen Living Unit 9235-20 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 4 Bath Rm 5 Rm 3 Bedroom Bedroom 1CO2 Side 1102 Spe 1 W01 Rm 2 1 LiOg Rm 1VBA01 Kitchen 1C01 1F01 Unit 9235=Office Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 3 Rm 4 Bath Bedroom 2W0 Side Side D B 1F02 Rm 1 Rm 2 2CO3 Kitchen Living Unit 9265-01 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rs h Rm 3 2WO4 Bedroom 2VBA02 Side Side 2F03 D Rm 1 Kitchen RM 4 2CO4 Living Unit 9265-04 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rill 3 Bath RM 4 RM 2 Bedroom Bedroom Side 2WO5 Side 2CO5 RM 1 RM 5 Kltcher Living Unit 9265-06 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Ba2 Bath 1W02 Rm 3 Bedroom 1CO2 1F01 Me Side 1W01 D B 1VBA01 Rm 1 1C01 Kitchen RM 4 Living Unit 9265=12 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 4 Rm 3 Bath Kitchen Living Bedroom 2C07 Side BF Side D Rm 1 RM Unit 9265-13 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM 19-258685 2 Project No. PARTNER 2 Kitchen Living 2C07 2W07 Side C Rm 3 Bath RITZ 4 RM 2 Bedroom Bedroom Se Side 2CO6 Rm 1 Rm 5 Kitchen Living Unit 9265=18 Side A Caesar's Square Apartments Not To Scale APPENDIX H: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Re C RM 3 Bath Rm 4 Rm 2 4VBA0 Bedroom 4FO2 Living SB e Side RM 5 4003 1 Bedroom Kitchen 4WO3 Unit 9295-101 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm2 Rm3 Living Bedroom 3C05 Side Side B Rm 1 Kitchen Rm 4 3W06 Bath Unit 9295-102 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 2 RM 3 RM 4 Living Bedroom Bedroom &de 3W01 Side B RM 1 3F01 3VBAO1 RM 5 Kltcher Bath 3C01 Unit 9295-103 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 4 Rm 3 Bedroom Bedroom Side 3W02B Rm2 Snide 3CO2 Living Rm 5 Rm 1 Bath Kitchen Unit 9295-107 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C 3C06 Rm 4 Rm 3 Rm 2 Bedroom Bath Lyng 3C07 Side Side D B Rm 5 Rm 1 Bedroom Kitchen 3W07 Unit 9295=205 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 2 Rm 3 Rm 4 Bedroom Bedroom Living Side 4WO2 Side 4FO1 Rm 1 Rm 5 Kitchen Bath 4WO1 4VBAO Unit 9325=08 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 3 Rm 2 Bedroom Living Side B Side D Rm 4 Rm 1 Unit 9325-12 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM No. 19-258685 2 Project PARTNER Bath 4W07 Kitchen a Side C Unit 9325-17 Side A Caesar's Square Apartments Not To Scale Side D APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Rm 2 Rm 3 Bedroom Living Rm 4 Bedroom 4W04 Rll1 1 4F02 RM 5 Kitchen Bath 4W03 Unit 9325-17 Side A Caesar's Square Apartments Not To Scale Side D APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Living Bedroom Rm 2 Rm 3 Rm 4 4W05 Side Rm 5 Side B Bath 4F03 Unit 9325=18 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM 2 Project No. 19-258685 PARTNER Living Bedroom Bedroom 4W05 Rm 1 Rm 5 Kitchen Bath 4F03 5ide Rm4 Bm3 Rm2 Bedroom Living Side Side 4W06 Rm 5 Rm 1 Bedroom Kitchen Unit 9325=20 Side A Caesar's Square Apartments Not To Scale APPENDIX H: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 2 Rm 3 Rm 4 Living Bedroom Bedroom Side Side B 5VBA02 5W03 Rm 1 5F02 Rm 5 Kitchen Bath Unit 9355-03 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 4 Rm 3 Bedroom Bath Rm 2 Living Side Side B D Rm 5 Rm 1 Bedroom Kitchen 5WO4 Unit 9355-06 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 &de C Rm 3 Bath Rm 4 Rm 2 5W02 Bedroom Living Side SB e p 5WO1 5VBAO1 Rm 5 Rin 1 Bedroom Kitchen 5FO1 Unit 9355-10 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm 2 Rm 3 Rm 4 Bedroom Bedroom Living Side Side 5W07 Rm 1 Rm 5 Kitchen Bath Unit 9355-13 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 Side C Rm8 Bedroom Rm 10 Rm 9 Bedroom Bedroom Rm 7 Side Bath B Rm 3 Hall 5W06 Side D 5W05 Rm 2 trM I Entry Rm 4 Rm 5 Rm 6 Utility Den Kitchen Living Unit 9355-21 Side A Caesar's Square Apartments Not To Scale APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER Project No. 19-258685 2 APPENDIX C: CERTIFICATIONS PARTNER Colorado Department of Public Health and Environment LEAD-BASED PAINT CERTIFICATION* This certifies that John Burnside Certification No.: 11876 has met the requirements of 25-7-1104, C.R.S. and Air Quality Control Commission Regulation No. 19, and is hereby certified by the state of Colorado in the following discipline: Risk Assessor* Issued: November 06, 2018 Expires: December 09, 2019 `This certificate is valid only with the possession of a valid lead-based paint training certificate in the discipline specified above, issued by either a Colorado approved training provider, an EPA approved training provider, or a training provider approved by another EPA authorized program. APM Representative SEAL APPENDIX D: PHOTOGRAPHIC DOCUMENTATION PARTNER AmaD°STTEP"oToG�s PARTNER Project No. 19-258685 2 AmaD°STTEP"oToG�s PARTNER Project No. 19-258685 2 AmaD°STTEP"oToG�s PARTNER Project No. 19-258685 2 AmaD°STTEP"oToG�s PARTNER Project No. 19-258685 2 APPENDIX E: XRF SAMPLING RESULTS PARTNER I Calibrate Positive 1 mg/cm2 0.1 2 Calibrate Positive 1 mg/cm2 0.1 3 Calibrate Positive 1 mg/cm2 0.1 4 923506 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 5 923506 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 6 923506 Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 7 923506 Rm. 01 C Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 S 923506 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 9 923506 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 10 923506 Rm. 02 A Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 11 923506 Rm. 02 A Door Casing Wood Black Intact Negative 0.02 mg/cm2 0.04 12 923506 Rm. 02 A Door Wood Stained Intact Negative 0.03 mg/cm2 0.05 13 923506 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 14 923506 Rm. 03 A Closet Door Wood Brown Intact Negative 0 mg/cm2 0.02 15 923506 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 16 923506 Rm. 04 D Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 17 923506 Rm. 04 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 16 923506 Rm. 04 D Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 19 923506 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 20 923506 Rm. 05 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 21 923506 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 22 923506 Rm. 05 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 23 923511 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 24 923511 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 25 923511 Rm. 01 D Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 26 923511 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cmc 0.02 27 923511 Rm. 02 A Door Casing Wood Brown Intact Negative 0 mg/cm2 0.02 26 923511 Rm. 02 A Door Wood Brown Intact Negative 0 mg/cm2 0.02 29 923511 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 30 923511 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 31 923511 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 32 923511 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 33 923511 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 34 923511 Rm. 05 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 35 923511 Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 36 923519 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 37 923519 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 36 923519 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 39 923519 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 40 923519 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 41 923519 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 42 923519 Rm. 03 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 43 923519 Rm. 03 D Wall Radiator Metal White Intact Negative 0.02 mg/cm2 0.1 44 923519 Rm. 03 D Door Jamb Wood Brown Intact Negative 0.2 mg/cm2 0.22 45 923519 Rm. 03 D Door Wood Brown Intact Negative 0 mg/cm2 0.02 46 923519 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 47 923519 Rm. 04 B Wall Drywall White Intact Negative 0.05 mg/cm2 0.9 46 923519 Rm. 04 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 49 923520 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 50 923520 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 51 923520 Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 52 923520 Rm. 01 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 53 923520 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cmc 0.02 54 923520 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 55 923520 Rm. 02 D Door Jamb Wood White Intact Negative 0.03 mg/cm2 0.05 56 923520 Rm. 02 D Door Wood White Intact Negative 0 mg/cm2 0.02 57 923520 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 56 923520 Rm. 03 A Door Jamb Wood White Intact Negative 0.12 mg/cm2 0.22 59 923520 Rm. 03 A Door Wood White Intact Negative 0 mg/cm2 0.02 60 923520 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 61 923520 Rm. 04 C Wall Radiator Metal White Intact Negative 0.01 mg/cm2 0.06 62 923520 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 63 923520 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 64 9235 Laundry Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 65 9235 Laundry Rm. 01 A Wall Drywall Green Intact Negative 0 mg/cm2 0.02 66 9235 Laundry Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 67 9235 Laundry Rm. 01 A Door Casing Wood Brown Intact Negative 0.01 mg/cm2 0.03 66 9235 Laundry Rm. 01 A Door Wood Brown Intact Negative 0.02 mg/cm2 0.06 69 9235 Office Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 70 9235 Office Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 71 9235 Office Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 72 9235 Office Rm. 01 C Cabinet Door Wood Stained Intact Negative 0.03 mg/cm2 0.06 73 9235 Office Rm. 01 A Wall Drywall Tan Intact Negative 0 mg/cm2 0.02 74 9235 Office Rm. 01 B Wall Drywall Tan Intact Negative 0 mg/cm2 0.02 75 9235 Office Rm. 01 B Wall Chair Rail Wood White Intact Negative 0 1 mg/cm2 0.02 76 9235 Office Rm. 03 A Wall Drywall Tan Intact Negative 0 mg/cm2 0.02 77 9235 Office Rm. 03 D Door Jamb Wood Stained Intact Negative 0.13 mg/cm2 0.14 76 9235 Office Rm. 03 D Door Wood Stained Intact Negative 0 mg/cm2 0.02 79 9235 Office Rm. 03 D Closet Door Wood White Intact Negative 0 mg/cm2 0.02 SO 9235 Office Rm. 03 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 81 9235 Office Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 82 9235 Office Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 83 9235 Office Rm. 04 D Cabinet Frame Wood Stained Intact Negative 0.05 mg/cm2 0.09 84 9235 Office Rm. 05 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 85 9235 Office Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 86 926501 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 87 926501 Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 SS 926501 Rm. 02 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 89 926501 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 90 926501 Rm. 02 A Door Casing Wood Stained Intact Negative 0.04 mg/cm2 0.06 91 926501 Rm. 02 A Door Wood Stained Intact Negative 0.05 mg/cm2 0.14 92 926501 Rm. 03 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 93 926501 Rm. 03 C Wall Radiator Metal White Intact Negative 0.04 mg/cm2 0.64 94 926501 Rm. 03 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 95 926501 Rm. 04 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 96 926501 Rm. 04 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 97 926501 Rm. 04 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 98 926501 Rm. 04 B Door Casing Wood White Intact Negative 0 mg/cm2 0.02 99 926501 Rm. 04 B Door Wood Brown Intact Negative 0 mg/cm2 0.02 100 926504 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 101 926504 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 102 926504 Rm. 01 D Wall Baseboard Wood White Intact Negative 0.01 mg/cm2 0.04 103 926504 Rm. 01 B Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 104 926504 Rm. 01 B Cabinet Frame Wood White Intact Negative 0.24 mg/cm2 0.23 105 926504 Rm. 02 B Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 106 926504 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 107 926504 Rm. 02 D Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 108 926504 Rm. 03 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 109 926504 Rm. 03 B Door Jamb Wood Stained Intact Negative 0.16 mg/cm2 0.18 110 926504 Rm. 03 B Door Wood Stained Intact Negative 0 mg/cm2 0.02 111 926504 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 112 926504 Rm. 04 A Door Casing Wood White Intact Negative 0 mg/cm2 0.02 113 926504 Rm. 04 A Door Metal White Intact Negative 0 mg/cm2 0.02 114 926506 Rm. 01 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 115 926506 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 116 926506 Rm. 01 B Wall Radiator Metal White Intact Negative 0.01 mg/cm2 0.03 117 926506 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 118 926506 Rm. 02 D Door Jamb Metal White Intact Negative 0.05 mg/cm2 0.08 119 926506 Rm. 02 D Door Metal White Intact Negative 0 mg/cm2 0.02 120 926506 Rm. 02 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 121 926506 Rm. 03 A Door Jamb Wood White Intact Negative 0.07 mg/cm2 0.09 122 926506 Rm. 03 A Door Wood White Intact Negative 0.05 mg/cm2 0.07 123 926506 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cmc 0.02 124 926506 Rm. 04 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 125 926506 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 126 926506 Rm. 04 B Door Jamb Wood White Intact Negative 0.06 mg/cm2 0.09 127 926506 Rm. 04 B Door Wood White Intact Negative 0 mg/cm2 0.02 128 926506 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 129 926506 Rm. 05 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 130 926506 Rm. 05 A Door Casing Wood White Intact Negative 0 mg/cm2 0.02 131 926506 Rm. 05 A Door Wood White Intact Negative 0 mg/cm2 0.02 132 926512 Rm. 01 D Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 133 926512 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 134 926512 Rm. 01 D Wall Shelf Wood White Intact Negative 0.02 mg/cm2 0.07 135 926512 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 136 926512 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 137 926512 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 138 926512 Rm. 02 D Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 139 926512 Rm. 02 D Door Casing Wood Brown Intact Negative 0.28 mg/cm2 0.22 140 926512 Rm. 02 D Door Wood Brown Intact Negative 0 mg/cm2 0.02 141 926512 Rm. 03 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 142 926512 Rm. 03 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 143 926512 Rm. 03 B Closet Door Wood Brown Intact Negative 0.08 mg/cm2 0.1 144 926512 Rm. 03 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 145 926512 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 146 926512 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 147 926512 Rm. 04 A Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 148 926512 Rm. 04 A Door Casing Wood Brown Intact Negative 0 mg/cm2 0.02 149 926512 Rm. 04 A Door Wood Brown Intact Negative 0.01 mg/cm2 0.03 150 926513 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cmc 0.02 151 926513 Rm. 01 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 152 926513 Rm. 01 D Cabinet Door Wood White Intact Negative 0.01 mg/cm2 0.03 153 926513 Rm. 01 D Cabinet Frame Wood White Intact Negative 0 mg/cm2 0.02 154 926513 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 155 926513 Rm. 02 A Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 156 926513 Rm. 02 A Window Sill Wood White Intact Negative 0 mg/cm2 0.02 157 926513 Rm. 03 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 158 926513 Rm. 03 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 159 926513 Rm. 04 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 160 926513 Rm. 04 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 161 926513 Rm. 04 B Wall Radiator Metal White Intact Negative 0.01 mg/cm2 0.05 162 926513 Rm. 04 D Cabinet Door Wood White Intact Negative 0.01 mg/cm2 0.04 163 926513 Rm. 04 D Cabinet Frame Wood White Intact Negative 0.28 mg/cm2 0.2 164 926518 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 165 926518 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 166 926518 Rm. 01 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 167 926518 Rm. 01 B Window Sill Wood White Intact Negative 0 mg/cm2 0.02 168 926518 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 169 926518 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 170 926518 Rm. 02 A Wall Shelf Wood White Intact Negative 0 mg/cm2 0.02 171 926518 Rm. 03 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 172 926518 Rm. 03 B Cabinet Door Wood White Intact Negative 0.01 mg/cm2 0.03 173 926518 Rm. 03 B Cabinet Frame Wood White Intact Negative 0 mg/cm2 0.02 174 926518 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 175 926518 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 176 926518 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 177 926518 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/cmc 0.02 178 926518 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 179 926515 Rm. 05 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 180 926515 Rm. 05 A Door Casing Wood Stained Intact Negative 0.01 mg/cm2 0.05 181 926518 Rm. 05 A Door Wood Stained Intact Negative 0.02 mg/cm2 0.07 182 9265 Laundry Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 183 9265 Laundry Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 184 9265 Laundry Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 185 9265 Laundry Rm. 01 A Door Jamb Wood Brown Intact Negative 0.01 mg/cm2 0.03 186 9265 Laundry Rm. 01 A Door Wood Brown Intact Negative 0.1 mg/cm2 0.21 187 9265 Laundry Rm. 01 B Wall Shelf Wood White Intact Negative 0 mg/cm2 0.02 188 9295101 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 189 9295101 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 190 9295101 Rm. 02 A Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 191 9295101 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 192 9295101 Rm. 02 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 193 9295101 Rm. 02 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 194 9295101 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 195 9295101 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 196 9295101 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 197 9295101 Rm. 03 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 198 9295101 Rm. 03 B Cabinet Door Wood White Intact Negative 0.27 mg/cm2 0.2 199 9295101 Rm. 05 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 200 9295101 Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 201 9295101 Rm. 05 C Door Jamb Wood Brown Intact Negative 0.11 mg/cm2 0.13 202 9295101 Rm.05 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.03 203 9295102 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 204 9295102 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 205 9295102 Rm. 01 B Cabinet Door Wood White Intact Negative 0.3 mg/cm2 0.25 206 9295102 Rm. 01 C Wall Shelf Wood White Intact Negative 0 mg/cm2 0.02 207 9295102 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 208 9295102 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 209 9295102 Rm. 03 A Door Jamb Wood Brown Intact Negative 0.11 mg/cm2 0.14 210 9295102 Rm. 03 A Door Wood Brown Intact Negative 0 mg/cm2 0.02 211 9295102 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 212 9295102 Rm. 03 A Closet Door Metal White Intact Negative 0 mg/cm2 0.02 213 9295102 Rm. 04 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 214 9295102 Rm. 04 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 215 9295102 Rm. 04 B Wall Radiator Metal White Intact Negative 0.06 mg/cm2 0.11 216 9295102 Rm. 04 B Door Casing Wood Brown Intact Negative 0.09 mg/cm2 0.1 217 9295103 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 218 9295103 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 219 9295103 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 220 9295103 Rm. 01 B Wall Radiator Metal White Intact Negative 0.02 mg/cm2 0.12 221 9295103 Rm. 02 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 222 9295103 Rm. 02 A Closet Door Metal White Intact Negative 0 mg/cm2 0.02 223 9295103 Rm. 02 A Closet Shelf Wood White Intact Negative 0.01 mg/cm2 0.04 224 9295103 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 225 9295103 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 226 9295103 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 227 9295103 Rm. 05 B Cabinet Door Wood Stained Intact Negative 0.4 mg/cm2 0.3 228 9295103 Rm.05 C Door Jamb Wood Brown Intact Negative 0.4 mg/cmc 0.4 229 9295103 Rm.04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 230 9295103 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 231 9295107 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 232 9295107 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 233 9295107 Rm. 01 A Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 234 9295107 Rm. 02 D Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 235 9295107 Rm. 02 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 236 9295107 Rm. 02 D Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 237 9295107 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 238 9295107 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 239 9295107 Rm. 04 A Door Jamb Wood Brown Intact Negative 0.16 mg/cm2 0.17 240 9295107 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 241 9295107 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 242 9295107 Rm. 05 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 243 9295107 Rm. 05 A Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 244 9295107 Rm. 05 D Cabinet Frame Wood Stained Intact Negative 0 mg/cm2 0.02 245 9295205 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 246 9295205 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 247 9295205 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 248 9295205 Rm. 01 A Door Jamb Wood Brown Intact Negative 0 mg/cm2 0.02 249 9295205 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 250 9295205 Rm. 02 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 251 9295205 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 252 9295205 Rm. 03 D Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 253 9295205 Rm. 03 D Wall Drywall White Intact Negative 0.01 mg/cm2 0.02 254 9295205 Rm. 03 D Cabinet Door Wood White Intact Negative 0.3 mg/cm2 0.22 255 9295205 Rm.04 C Ceiling Drywall White Intact Negative 0 mg/cmc 0.02 256 9295205 Rm.04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 257 9295205 Rm. 04 C Wall Radiator Metal White Intact Negative -0.1 mg/cm2 0.93 258 9295205 Rm. 04 C Window Sill Wood White Intact Negative 0.01 mg/cm2 0.02 259 9295205 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 260 9295 Laundry Rm. 01 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 261 9295 Laundry Rm. 01 C Wall Shelf Wood White Intact Negative 0 mg/cm2 0.02 262 Calibrate Positive 1 mg/cm2 0.1 263 Calibrate Positive 1 mg/cm2 0.1 264 Calibrate Positive 1 mg/cm2 0.1 265 932508 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 266 932508 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 267 932508 Rm. 01 A Cabinet Frame Wood White Intact Negative 0.4 mg/cm2 0.4 268 932508 Rm. 02 B Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 269 932508 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 270 932508 Rm. 02 B Wall Radiator Metal White Intact Negative 0.01 mg/cm2 0.06 271 932508 Rm. 02 A Door Wood Brown Intact Negative 0.21 mg/cm2 0.15 272 932508 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 273 932508 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 274 932508 Rm. 03 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 275 932508 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 276 932508 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 277 932508 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 278 932508 Rm. 04 A Door Jamb Wood White Intact Negative 0.19 mg/cm2 0.19 279 932508 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 280 932508 Rm. 05 B Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 281 932508 Rm. 05 D Closet Door Wood White Intact Negative 0 mg/cm2 0.02 282 932508 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 283 932505 Rm. 05 C Door Jamb Wood White Intact Negative 0 mg/cm2 0.02 284 932517 Rm. 01 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 285 932517 Rm. 01 C Cabinet Door Wood White Intact Negative 0.07 mg/cm2 0.18 286 932517 Rm. 02 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 287 932517 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 288 932517 Rm. 02 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 289 932517 Rm. 02 A Door Casing Wood Brown Intact Negative 0 mg/cm2 0.02 290 932517 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 291 932517 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 292 932517 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 293 932517 Rm. 03 A Door Jamb Wood Stained Intact Negative 0.27 mg/cm2 0.21 294 932517 Rm. 03 A Door Wood Stained Intact Negative 0 mg/cm2 0.02 295 932517 Rm. 05 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 296 932517 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 297 932517 Rm. 05 B Cabinet Frame Wood White Intact Negative 0.26 mg/cm2 0.21 298 932518 Rm. 01 A Ceiling Drywall White Intact Negative 0.02 mg/cm2 0.09 299 932518 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 300 932518 Rm. 01 A Cabinet Frame Wood White Intact Negative 0.18 mg/cm2 0.23 301 932518 Rm. 01 A Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.03 302 932518 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 303 932518 Rm. 02 B Wall Radiator Metal White Intact Negative 0.03 mg/cm2 0.11 304 932518 Rm. 02 A Door Casing Wood Stained Intact Negative 0 mg/cm2 0.02 305 932518 Rm. 02 A Door Wood Stained Intact Negative 0.17 mg/cm2 0.17 306 932518 Rm. 03 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 307 932518 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 308 932518 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/cmc 0.02 309 932518 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 310 932515 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 311 932515 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 312 932515 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 313 932515 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 314 932520 Rm. 01 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 315 932520 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 316 932520 Rm. 01 A Door Jamb Wood Brown Intact Negative 0.01 mg/cm2 0.05 317 932520 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 318 932520 Rm. 01 A Cabinet Frame Wood White Intact Negative 0 mg/cm2 0.02 319 932520 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 320 932520 Rm. 04 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 321 932520 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 322 932520 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 323 932520 Rm. 04 A Door Jamb Wood Stained Intact Negative 0.28 mg/cm2 0.22 324 932520 Rm. 04 A Door Wood Stained Intact Negative 0 mg/cm2 0.02 325 932520 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 326 932520 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 327 932520 Rm. 05 B Window Sill Wood White Intact Negative 0 mg/cm2 0.02 328 932520 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 329 932520 Rm. 12 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 330 932520 Rm. 12 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 331 932520 Rm. 12 A Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 332 932520 Rm. 02 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 333 932520 Rm. 02 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 334 932520 Rm. 02 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 335 932520 Rm. 02 C Window Sill Wood White Intact Negative 0 mg/cmc 0.02 336 932520 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 337 932520 Rm. 03 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 338 932520 Rm. 03 A Door Jamb Wood Stained Intact Negative 0.21 mg/cm2 0.17 339 932520 Rm. 03 A Door Wood Stained Intact Negative 0 mg/cm2 0.02 340 932520 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 341 932520 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 342 932520 Rm. 03 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 343 932520 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 344 932520 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 345 932520 Rm. 04 C Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 346 932520 Rm. 04 D Door Casing Wood Stained Intact Negative 0.4 mg/cm2 0.3 347 932520 Rm. 04 D Door Wood Stained Intact Negative 0 mg/cm2 0.02 348 935503 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 349 935503 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 350 935503 Rm. 01 A Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 351 935503 Rm. 02 A Door Casing Wood Brown Intact Negative 0 mg/cm2 0.02 352 935503 Rm. 02 A Door Wood Brown Intact Negative 0.03 mg/cm2 0.07 353 935503 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 354 935503 Rm. 02 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 355 935503 Rm. 03 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 356 935503 Rm. 03 A Wall Drywall White Intact Negative -0.1 mg/cm2 0.81 357 935503 Rm. 03 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 358 935503 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 359 935503 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 360 935503 Rm. 03 A Closet Jamb Wood White Intact Negative 0 mg/cm2 0.02 361 935503 Rm. 03 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 362 935503 Rm. 03 A Door Jamb Wood White Intact Negative 0.4 mg/cmc 0.5 363 935503 Rm. 04 A Door Casing Wood White Intact Negative 0.28 mg/cm2 0.43 364 935503 Rm. 04 A Closet Jamb Wood White Intact Negative 0 mg/cm2 0.02 365 935503 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 366 935503 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 367 935503 Rm. 05 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 368 935503 Rm. 05 D Closet Door Wood White Intact Negative 0 mg/cm2 0.02 369 935503 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 370 935503 Rm. 05 B Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 371 935503 Rm. 05 C Door Jamb Wood White Intact Negative 0.17 mg/cm2 0.2 372 935503 Rm. 05 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 373 935506 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 374 935506 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 375 935506 Rm. 01 A Door Casing Wood Stained Intact Negative 0.4 mg/cm2 0.3 376 935506 Rm. 01 A Door Wood Stained Intact Negative 0.08 mg/cm2 0.1 377 935506 Rm. 02 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 378 935506 Rm. 02 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 379 935506 Rm. 03 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 380 935506 Rm. 03 D Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 381 935506 Rm. 03 D Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 382 935506 Rm. 03 B Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 383 935506 Rm. 03 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 384 935506 Rm. 03 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 385 935506 Rm. 03 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 386 935506 Rm. 03 A Closet Shelf Wood White Intact Negative 0.02 mg/cm2 0.09 387 935506 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 388 935506 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 389 935506 Rm. 05 B Window Sill Wood White Intact Negative 0 mg/cmc 0.02 390 935510 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 391 935510 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 392 935510 Rm. 01 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 393 935510 Rm. 01 B Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 394 935510 Rm. 01 B Cabinet Frame Wood Stained Intact Negative 0 mg/cm2 0.02 395 935510 Rm. 02 C Ceiling Drywall Stained Intact Negative 0 mg/cm2 0.02 396 935510 Rm. 02 C Wall Drywall Stained Intact Negative 0 mg/cm2 0.02 397 935510 Rm. 02 C Door Casing Wood Stained Intact Negative 0 mg/cm2 0.02 398 935510 Rm. 03 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 399 935510 Rm. 03 B Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 400 935510 Rm. 03 B Door Wood Stained Intact Negative 0.26 mg/cm2 0.2 401 935510 Rm. 03 B Door Wood Stained Intact Negative 0.11 mg/cm2 0.12 402 935510 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 403 935510 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 404 935510 Rm. 04 A Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 405 935510 Rm. 05 D Wall Drywall White Intact Negative 0 mg/cm2 0.02 406 935510 Rm. 05 D Window Sill Wood White Intact Negative 0 mg/cm2 0.02 407 935510 Rm. 05 D Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 408 935513 Rm. 01 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 409 935513 Rm. 01 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 410 935513 Rm. 01 A Cabinet Frame Wood White Intact Negative 0.4 mg/cm2 0.3 411 935513 Rm. 01 A Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 412 935513 Rm. 02 C Door Casing Wood White Intact Negative 0 mg/cm2 0.02 413 935513 Rm. 04 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 414 935513 Rm. 04 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 415 935513 Rm. 04 A Door Jamb Wood Stained Intact Negative 0.23 mg/cm2 0.18 416 935513 Rm. 04 A Door Wood Stained Intact Negative 0 mg/cmc 0.02 417 935513 Rm. 04 C Wall Radiator Metal White Intact Negative 0 mg/cm2 0.02 418 935513 Rm. 04 C Window Sill Wood White Intact Negative 0 mg/cm2 0.02 419 935513 Rm. 05 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 420 935513 Rm. 05 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 421 935513 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 422 935513 Rm. 05 B Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 423 935513 Rm. 05 D Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 424 935521 Rm. 02 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 425 935521 Rm. 04 C Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 426 935521 Rm. 04 C Wall Drywall White Intact Negative 0 mg/cm2 0.02 427 935521 Rm. 04 C Wall Baseboard Wood White Intact Negative 0 mg/cm2 0.02 428 935521 Rm. 04 C Door Jamb Wood White Intact Negative 0 mg/cm2 0.02 429 935521 Rm. 04 C Door Wood White Intact Negative 0 mg/cm2 0.02 430 935521 Rm. 05 B Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 431 935521 Rm. 05 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 432 935521 Rm. 05 B Cabinet Frame Wood Stained Intact Negative 0 mg/cm2 0.02 433 935521 Rm. 05 B Cabinet Door Wood Stained Intact Negative 0 mg/cm2 0.02 434 935521 Rm. 07 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 435 935521 Rm. 07 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 436 935521 Rm. 07 A Cabinet Door Wood White Intact Negative 0 mg/cm2 0.02 437 935521 Rm. 07 B Door Jamb Wood Brown Intact Negative 0.4 mg/cm2 0.2 438 935521 Rm. 07 B Door Wood Stained Intact Negative 0.26 mg/cm2 0.25 439 935521 Rm. 09 A Ceiling Drywall White Intact Negative 0 mg/cm2 0.02 440 935521 Rm. 09 A Wall Drywall White Intact Negative 0 mg/cm2 0.02 441 935521 Rm. 09 B Wall Drywall White Intact Negative 0 mg/cm2 0.02 442 935521 Rm. 09 B Closet Shelf Wood White Intact Negative 0 mg/cm2 0.02 443 935521 Rm. 09 C Window Sill Wood White Intact Negative 0 mg/cmc 0.02 444 935521 Rm. 09 C Window Casing Wood White Intact Negative 0 mg/cm2 0.02 0611612015 13:15 f P.0041004 i Date. plall ` P&t 6 oral, Plumbing: Litt m # City U.i d c4 A. R a % i OWNEWCONTRACTOR SIGNATIVRE Of UNDEMANDING AND AGREEMENT ,. ` t b .: t 4: is w i t h ♦• ` 4 t A t • •.. t t. t♦ t z: '. A t 5 R :: t t �i.:. B i t " t't t t i i. - :4M .t. i.. - si, '..t t t tr. % ! : • : i • t....t i Mt t.. i ': *. .: t ♦' ♦... s ,I♦ t ! - a`;., t i... � t ii= 3 aR R : i ,:: t..' R b t °i;,. `4 s t t. ^k •P=! ( '% S tk ": ftA : t % : f *"e.Ai �'. t =♦ 4 Jmlz Rovifte %. ■ M t OOi tib i t ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: 44Ji r/,7 uviiu.� .JS Job Address: 9 5;0,5 Permit Number: lO >32o E7G7 aY S f A Tex wAVg;o " i; ?,lt " f-'>i/2 tdsL✓t�a�JS ❑ No one available for inspection: Time :S AM M Re- Inspection required: E R No * When corrections have been made, Gaff for re inspection at 303 Date: 7 is Inspector 7 DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE r4000r uilding Inspection Division (303) 234 -5933 Inspection line 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: /3�� c /cri�a/ra�uo5 Job Address: >��ZS ,y, yFStrf /�yf sr0 Permit Number: f011® ❑ No one available for inspection: Time ff, A PM Re- inspection required: Yes N ' "When corrections have been made, call for re- Inspection at 303- 234 -5933 Date: f/ /® Inspector: DO NOT REMOVE THIS NOTICE Cit �f Y COMMUNITY DEVELOPMEN I Building & Inspection Services Division 7500 W. 29 Wheat Ridge, CO 80033 Office: 303 -235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Building Permit Application Property Address_ !• 29 5 W l /'� ✓{ Property Owner (please print) J C H f Phone Mailing Address; (if different than property address) Address: City, State, Zip: 9000 ctor: W l evo 0 rN5 r'r^ Ctir L ✓I Contractors City License #: Phone: S Wli Contractors: Electrical: Plumbing: Mechanical: City License # /0-0140 City License # City License # T3 o k i / 7 L„rnl0aw5 t`EQ(/jGE 5(NGt e AwAt t/.'s- 64**" c- Contract Value: W wi jj'L_ birao L ¢ ir�Gaw Vf FrLs e -lev4GCY Gt rlfcievur Review Fee (due at time of submittal): Squares BTU's Gallons Amps Sq Ft: $ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants; easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge . codes and ordinances for work under any permit issued based on this application; than am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity . on this application. CIRCLEONE.' (OWNER) (CONTRACTOR). or (AUTHORLZEDREPRESE)Y TIVE) of (OWNER) (CONTRACTOR) PRINT NAME: e4 a. L{/yVQf fli SIGNATURE: r DATE: . � � ✓ , +� � ` ` " �� y „ ° d . ZONING COMN(ENTS f . r- - a -.=-s -"a 'a. ✓—. ,..r`��✓ —✓ ,,-. ✓ r _ ✓ ,✓ ,_ '. ✓ z zO.JJ}n.9 "��j. `� �t� ✓' r a ��r ✓� `. ✓' ' ✓i✓✓ > .',.✓�✓ a� r_ i '�✓�,� rf? ;1 ay,+u'✓; � � ReU10W2Y � s � i � h '�," ,✓� ✓�� � n 9 � e �� � r � y : ✓ � I � j e r l / . yrs � � � ✓ e � �� � �✓ " ✓✓+' ��� � i�d� y ��� �� ri 4 �� ✓a✓ r $UILPING DEPART(�IEN7 COMM) =NTS �/ i : `"%" ✓ i � : j i ✓ ` z `' - ReY18WeP ✓ �. ,,✓ � ✓ ✓ � . ,�" i al '✓ '`� � T �✓ P »yv v � ✓ l> ✓ ", /✓ � i ✓ do- j . r c� ✓ � !' , ✓ �, � ✓ +-. -. r -c �. t. _✓ a ✓.. 1j -S �'F a } 4„" ! tPU6LIC WORKS COry7MEpTS. ✓' ^"" r -r �`✓ r ssyz � 1 4CCUPANCY � ReVlewer �� . l ,✓i :. A � % ✓�'� � / �� �`° a y sv ¢ :�, 'FIRE REPARTMENT" ❑ approYe�ivl comments fi7 �ISapproved D J19 rewew,�Ye�Glred ; Bldg Valuation $ e ® ! s CITY OF WHEAT RIDGE Building Inspection Division d (303) 234 -5933 Inspection tine (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: sue. Job Address: Permit Number: /D tJ <° 7 ❑ No one available for inspection: Time AM /PM Re- Inspection required: Yes No ,a When corrections have been made, call for re-inspection at 303 -234 -5933 Date: z O Inspector: DO NOT REMOVE THIS NOTICE City of Wheat idle Date: ~MU.NiTY DEVELOPMENT ~~jjj Pennrt j C~~~ Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-237-8929 Inspection Line: 303-234-5933 Facsimile, Building Permit Application Property Address; gQgS (,v, 4h Avio Property Owner (please print): ~t is(►1Q `~1 (-f j, Phone. Mailing Addrr~~ss: (if different than mperty address) Address:Ilai2ir) t,-% fl~1ti W,,,o. Contractor: License#: (-)I f `X%SS - Phone: ~j~ 11 cJd - Sub Contractors: Company Nome; License M Expiration Pate: Trade/Profession: Approval: Use of sppace (description): Mno J K.,,T l~1;rb Description oTw``ork: Nu, ('ePl0.C4h•ev~k' . Plan Review (due at time of subm0aq: S Sq. Ft./L Ft added' Squares BTU's 143-46-N Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (La.C) and all other applicable Wheat Ridge ordinances, for work under this permit. Plane subjectto field Inspection. C/RLCEONE;: (OWNER) CONTRACTOR or PERSONAL RE SEN TI i(OWNER) (CONTRATOR) PRINT NAME: ar1tmi SIGNATU Date; q-as-lc ZONING COMMENTS: Zoning; Reviewer. PUBLIC WORKS COMMENTS: Reviewer; DEPARTMENT USE`BNLY BUILDING DEPARTMENT COMMENTS: OCCUPANCY: Reviewer. FIRE DEPARTMENT.; O approved w/ comments ❑ disapproved in no review required- Bldg Valuation: $ Credit Card P yment: Use credit card listed on file% Da _ -lC7 Print name: ,-e I_C4rrl~LgyL Signaturqi,_ ♦ 4 i CITY OF WHEAT RIDGE "~-j Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: M-R7?,*1 A-Q~o IIV. _2P Job Address: 1,-.1 ~V;-/a , ~ Permit Number: _'~6559'7 2 ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector: DO NOT REMOVE THIS NOTICE 0 3 a 0 yoH ~ ^OZ o mom mm 300y u m~ ma x~ naa~ 'm my o3md n mcR $ oa D as o a6 my Sry n~ yV N O J P3 < ymmN < 3 O- Om c m °00?1~ o 7 y ?L7c3 d al gF o n osm 0 C Ury j < A-w o N H~o N 1n'a.d N 3m° oW j dGz T,~m rv m o>fyr R- .0-'3 °0F3 o.ss niON~ ws~~ m~.0 zo 3y,m m w~ II 0 ^c m°pm yF j~ ~N w^ dm0y °2 T16 6S n wTT3~ o w_O 9192 S o2Km vem3 m s w. mm y?. 0000 Q 'aF dn~3. O oa= g=. S ma;cm ,~som w~a Oy10 ~ Od0 _w Gay o^w>> ~m5 W N MR, FPmdom3n~ O3c w" C1 Oc d o no Fnm~mo`0 rvmm nv~~ro.~n_ omw_. w _ m m3,o m~'g°i'o'd- 0-0 x om° m ¢mwF"m<.m E 3 Z aOl mII w~..ym^ msm W. mo nFy~amo ~6~,~m9 3xam d,nob 5Z0 vOZ czn 3 wN PmII~°°~ w3~ ~0+~ 'J d~m~Ny~C.nC YmiyN HOC 9 NO=F O'mFN w.~ ;m d'°=mc mn°-tn'o m mD o^ro w'.0g-s om. 0c 0 m yo3a.9.t^3m Via. ~ =~c°o~D nOm O~° d m T m a 3 Pm^ n c'0^^>0o $ P n ~O F~m,0OTmo ny `G v y~xo y ~c't7oo mw0 m 131 ~O~yO-~ yd NOmC^N G10 J O n mQSoE~nv ~P u cQs'i t001pN ].0-. 0 o<o n~oo o'y 1no O 3 n J OJ J T A q 0--0J OK> NO O.S 4y m. p<,w 4o 1 p, ~.~0 NNW ~ wlwO^m 1 Pjyd Jdy y ~ d i .9O o nF mm o- ma~.o Sao o Tc cs I ~mO amro `pow m pm oN f F~'dP Om O m m a oo P g m» mn n m d 6» p~ d°O d O N OR y w J n y0 O N c M.z v~ v yF oG c SO j 190 ) 3 nDw OD v S~F mo° o. E a ^m X IIN mm sm ~m m 0 ma m mO r N ^ c o ' mmny a' ,vy m mdm nm m 9 @ s w Acp s x 9 o = =oMc cma o np`ma m o=O m ov GAZ C w3 do m m .:Em OR 00 w-y 3m 3m mdm On at 6 dry Ln N ' E3m 6 a - my m ma y j"'O. sn w41 m mew oP m II yd do n6 sw n1 °m yZ m m BE ~my R ,g H3. e~ - mm c J y` y iG0 ~6 N 3 N ~w O&M 0w p~ .6- off= QN EP3 mw -RI o m m Om °v c Dom ~m m wto ca 3 NP~l ~m NS qa mm O mm p »s O F m10 Jy fD ON m N fpm w n m a-. ma d n OA ~d 3y ~o > m~ HN m o n r0 9 mm o S m O o r n mo o m -Jlpp.W SNm -1 n a v o D ~I [Am ZO sm = m a m o n=wwm's msz m 0 m m T m y mw Nio <°oG1 a O o i m 3 mac~0 _.w D~ p m m ~ m w T m O O m N o m, n m m0TD DO 000 D 3m ooh De xv Zo dNL) 03D II VT s m mc neaw 063 NN 9:9 Om 006 N O m mn :ma >m 0 DQN 230: n=. w- 3- 0 O o c SOO :oy .00- am mo9 y m w t.P 2 0c '0- m '2 y°2 oc "Ps c_ .9. 1nN .c .MF oa ~SO u_,O Oda 3 0O r z" HO ^.m 0Fm ~3 " cw5 o~ w°w yF w m yNz0 D ~T na o mo0 9x ss~. mm m 0 0 T z c~ n O 0 z m O z 'D Gl z m a y y t O I z o m s m i Z O N O b m o a y w N N pppq~L m y g 8 g W a m z 0 m O 0 m0 m a O D m 9 D H 3 m H V! F z m m m y 0 0 yC C O N e 0 mm C a O O 09 a~ O mm ~D O ZN 7} Cl ^'V Z N O O A ♦ A ♦ CITY OF WHEAT RIDGE ,-V, Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: Pali d°' Job Address: 7,?YS k,+. Yg'5, w.rel Permit Number: r9?n 5'9;r r ArP c ti 10t4) nsair, . ~e saae~ l= a1e11 770nj ,Peg ee/e9 .fig i 4-av sd 4w or ~?f~ 6?Gn_.~aa> s uar!/ anarea~ ssrme~F cs~ l~s ~~nr3~E~ ~r _<040 49C7- AQ2.2 14d /41 , 7 ❑ No one available for inspection: Time AM/PM Re-Inspection required: No "When corrections have been made, call for re-inspection at 303-234-5933 Date: /✓e%'9' Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE r Building Inspection Division 1 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE d ✓n1S6? Inspection Type: F4AR7"1,4'1 Job Address: 7;27,` Et,, ~9711 fcrs6 .SAW Permit Number: 417~c 5P7 m eF_ f w fps/>'~ iacd jew &,4*0 rz~¢ u~~ co al ~a r~ i JL &Ye. g. t, ❑ No one available for inspection: Time 11,,7P AM/PM r- y Re-Inspection required: Yes No - Es rid,~smJ When corrections have been made, call for re-inspection at 303-234-5933 ~I ~ j Date: 6,1571091 Inspector: 1~/° i DO NOT REMOVE THIS NOTICE t; City of Wheat Ridge ` Commercial Roofing PERMIT - 090587 s PERMIT NO: 090587 , ISSUED: 06/02/2009 ' JOB ADDRESS: 9295 W 48TH AVE N zEXPIRES: 11/29/2009 DESCRIPTION:... T/0 resheath, 4 plies of fiberglass felt & gravel CONTACTS owner 303/422 8600 Jeffco Housing Authority sub 303/295-77G9 Robert Tichy 01-7911 Alpine Roofing Co.,.:: Inc. x P PARCEL INFO ZONE :CODE: UA 'USE: UA SUBDIVISION: 0044 `BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 60,275.00. u, FEES Permit Fee ! 937.05 - Total Valuation .00 L~h{"LY7IF Use -Tax - 1,084.95 TOTAL 2,022.00 ~y Conditions: r Subject to field inspections. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable " ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate ; that I have read and agree to abide. by all conditions printed on this gnature of contractor/owner e t forth in your and is subject to the. laws of the orado or any'. other applicable be received :prior to expiration normally required, provided no pension or. abandonment has not ne (1) year,t full fees shall a drainage problem. 11 inspections and shall receive b`. date ~oF W"s^^qo City of Wheat Ridge Building Division ~m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 " Fax: 303-235-2857 c o inspection Line: 303-234-5933 OLORP~ Building Permit Application Date: Plan Permit CI Pr Property Address; 9295 West 48th Ave., Wheat Ridge CO Property Owner (please print): Jefferson County Housing Authority Phone: 303-422-8600 Mailing Address: (if different than property address) Address: 7490 W 45th Ave City, State, Zip: Wheat Ridge CO 80033 ~ontracto: ALPINE ROOFING CO., INC Contractor License 17911 Phone: 303-295-7769 Su6Contraefbrs Electrical City License Plumbing City License Mechanical City License Company: Company Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use Off s ace (descrtion): Apartment Bldg Construction Value: $60,275.00 '~@SCTIPOn_Of W07, 95 Squares -Tear off the exising roofing (as calculated per the Building Valuation Data sheet) install tapered insulation, 1/2" cover board, 4 plies of fiberglass Plan Review (due at time. ofsubmittaq: $ felt, and. gravel, including misc sheet metal Sq. Ft./L. Ft added: Squares "I v,l . BTU's Gallons Amps OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I. hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances; rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR) PRINT NAME: ROBERT D. TICHY, PRESIDENT. SIGNATURE: Date: 611/09 Z. qrtlcle Number or 7160 3407, 9644 2844 2813 3. Service Type CERTIFIED MAIL 4. Resirictetl Delivery? (EMre Fee) 1. Anicle Atldressetl to: ~~Yes Re: 9295 W. 48th Ave. X ~W j~v"z u. is tlalivery atltlrass tliflerent irom den I~ YES, enter delivery atltlresy pelm¢ Jefferson County Housing Authority 6025 W. 38th Ave. Wheat Ridge, CO 80033 l ~ ~oOs \ . 917, July 2001 Domestic Return Receipt - • A ~ . aF WHEql 7160 3901 9844 2844 2813 0 o m SENDERS • ' . ~~l ORA~ NOTICE AND ORDER To PROPERTY OWNER AND ALL CURRENT OCCUPANTS Pursuant to the 1997 Edition and the Uniform Code for the Abatement of Dangerous Buildings, the 1997 Uniform Housing Code and the 2003 International Property Maintenance Code, the following property is in violation. According to County Records you are the property owner of the described property in violation. Apri15, 2005 Property Owner: Attn: Jefferson County Housing Authority 6025 W. 38`h Ave. Wheat Ridge CO, 80033 Property Description: 243800 F'ICCO SUB or commonly known as: 9295 W. 48th v` Stfeet. Unit B-2, Wheat Ridge Colorado 80033 NOTICE The property owner, and all current occupants, are hereby notified that the undersigned Building Official of Wheat Ridge, Colorado, has found the building located on the above described real property to be a Dangerous Building within the meaning of Section 302 of the Uniform Code for the Abatement of Dangerous Buildings, 1997 edition, as adopted by the City of Wheat Ridge, Colorado ("Code"), as more particularly set out below: The building is being used for dwelling purposes and is in violation of the Uniform Code for the Abatement of Dangerous Buildings, sections in bold are the sections that this property is in violation of. SECTION 301- GENERAL For the purpose of this code, certain terms, phrases, words and their derivatives shall be construed as specified in either this chapter or as specified in the Building Code or the Housing Code. Where terms are not defined, they shall have their ordinazy accepted meanings within the context with which they are used. We6ster's Therd new International Dictionary of the English Language, (Inabridge, copyright 1986, shall be construed as providing ordinary accepted meanings. Words used in the singular masculine gender include the feminine and the feminine the masculine. BUILDING CODE is the /nternational Code Council, as adopted by this jurisdiction. DANGEROUS BUILDING is any building or structure deemed to be dangerous under the provisions of Section 302 of this code. HOUSING CODE is the Uniform Housing Code promulgated by the In[erna[ional Conference of building Officials, as adopted by fhis jurisdiction. INTERNATIONAL PROPERTY MAINTENANCE CODE is the 2003 International Property Maintenance Code promulgated by [he International Code Council, as adopted by this jurisdiction. SECTION 302 - DANGEROUS BUILDING For the purpose of [his code, any building or struc[ure which has any or all of [he conditions or defects hereinafrer described shall be deemed [o be a dangerous building, provided [hat such conditions or defects exist to the extent [hat the life, health, property or safety of the public or i[s occupants are endangered. 1. Whenever any door, aisle, passageway, stairway or other means of exit is not of sufficient width or size or is not so artanged as to provide safe and adequa[e means of exit in case of fire or panic. 2. Whenever the walking surface of any aisle, passageway, s[airway or other means of exit is so warped, worn. Loose, [orn or otherwise unsafe as [o no[ provide safe andadequate means of exit in case of fire or panic. 3. Whenever the svess in any ma[erials, member or portion thereof, due to all dead and life loads, is more than one and one half times the working stress or svesses allowed in the Building Code for new buildings of similar structure, purpose or location. 4. Whenever any portion thereof has been damaged by fire, ear[hquake, wind, flood or by any other cause, to such an ex[ent [hat [he sUuctwal sVeng[h or s[ability [hereof is ma[erialty less than it was before such catastrophe and is less than [he minimum requirements of [he Building Code for new buildings of similar struc[ure, purpose or location. 5. Whenever any portion or member or appurtenance thereof is likety to fail, or co become detached or dislodged, or to collapse and thereby injure persons or damage property. 6. Whenever any poRion of a building, or any member, appurtenance or ornamentation on the exterior thereof is not of sufficien[ svength or stability, or is not so anchored, attached or fastened in place so as to be capable of resis[ing a wind pressure of one half of that specified in [he building Code for new buildings of similar struc[ure, purpose or location wi[hou[ exceeding the working sVessed permitted in the Building Code for such buildings. 7. Whenever any portion thereof has wracked, warped, buckled or settled to such an extent that walls or other svuctural portions have materially less resistance to winds or earthquakes than is required in the case of similar new consVUCtion. 8. Whenever the building or structure, or any portion thereof, because of (i) dilapidation, deterioration or decay; (ii)faulry construction; (iii) the removal, movement or instability of any portion of the ground necessary for the purpose of supporting such buildings; (iv) the deteriora[ion, decay or inadequacy of its foundation; or (v) any o[her cause, is likely [o partially or completely collapse. 9. Whenever, for any reason, the building or structure, or any portion thereof, is manifestly unsafe for purpose of which it is being used. 10. Whenever the exterior walls or other vertical svuctwal members list, lean or buckle to such an extent that a plumb line passing through [he cen[er of gravi[y does no[ fall inside the middle on third of the base. 11. Whenever the building or strucmre, exclusive of the foundation, shows 33 percent or more damage or deterioration of its supporting member or members, or 50 percen[ damage or de[erioration of i[s non-supporting members, enclosing or ou[side walls or coverings. 12. Whenever the building or structure has been so damaged by fire, wind, earthquake or flood, or has become so dilapidated or deteriorated as ro become (i) an attractive nuisance ro children; (ii) a harbor for vagrants, criminals or immoral persons; or as to (iii) enable persons to resort thereto for [he purpose of commi[ting unlawful or immotal acts. 13. Whenever any building or structure has been coustructed, exists or is maintained in violation of any specific requirement or prohibition applicable to such building or structure provided by the building regulations of this jurisdiction, as specified in the Building Code or Housing Code, or of any law or ordinance of this state or jurisdiction relating to the condition, location or structure of buildings. 14. Whenever any building or s[ruc[ure which, whether or not erected in accordance with a alI applicable laws and ordinances, has in any non-supporting part, member or portion less than 50 percen[, or in any supporting pazt, member or portion less [he 66 percent or the (i) strength, (ii) fire-resisting quali[ies or characteristics, or (iii) wea[her-resis[ing qualities or characteristics required by law in the case of a newly constructed building of like azea, height and ocwpancy in the same location. 15. Whenever a building or sVUCture, used or intended ro be used for dwelling purposes, because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangemen[, inadequate light, air or sanitation facilities, or otherwise, is determined by the health officer to be unsanitary, unfit for human habitation or in such a condi[ion that is likely ro cause sickness or disease. 16. Whenever any building or structure, because of obsolescence, dilapidated condition, deterioration, damage, inadequate exists, lack of sufficient fire-resistive cons[ruction, faulty elecVic wiring, gas connections or heating appaza[us, or other cause, is de[ermined by [he fire marshal ro be a fire hazard. 17. Whenever any building or structure is in such a condition as ro cons[itute a public nuisance known to [he common law or in equity jurisprudence. 18. Whenever any por[ion or a building or shacture remains on a site after the demoli[ion or destruction of the building or sVUCture or whenever any building or s[ruc[ure is abandoned for a period in excess of six mon[hs so as to consti[u[e such building or portion thereof an attractive nuisance or hazazd [o [he public. The 1997 Uniform Housing Codes states; SECTION 1001 -DEFINITIONS 1001.1 General. Any building or portion thereof that is de[ermined ro be an unsafe building in accordance with Section 102 of the Building Code, or any building or portion thereof, including any dwe]ling unit, gues[ room or suite or rooms, or the premises on which the same is located, in which there exists any of the conditions referenced in this section ro an extent that endangers the life, limb, health, property, safety or welfaze of the public or the occupants thereof, shall be deemed and hereby are dulared ro be substandard buildings. 1001.2 Inadequate Sanitation. Buildings or portions thereof shall be deemed substandazd when they are when they are in sanitary. Inadequate sanitation shall include, but not be limited to, the following: 1. Lack of or improper water closet, lavatory, bathtub or shower in a dwelling unit or lodging house. 2. Lack of or improper water close[s, lavatories, and ba[htubs or showers per number or guests in a hotel. 3. Lack of or improper kitchen sinlc in a dwelling uni[. 4. Lack of hot or cold running water [o plumbing fixtures in a ho[eI 5. Lack of hot or cold running water [o plumbing 5xtures in a dwelling uni[ or lodging house. 6. Lack of adequate heating facilities. 7. Lack of or improper operation or required ventilating equipmen[. 8. Lack of minimum amounts of natural light and ven[ila[ion require by this code. 9. Room and space dimensions ]ess [han required by this code. 10. Lack of required elecvical lighting. 11. Dampness of habitable rooms. 12. Infestation of insec[s, vermin or roden[s as determined by the health officer. 13. General dilapidation or improper maintenance. 14. Lack of connection to required sewage disposal system. 15. Lack of adequate garbage and rubbish s[orage and removal facilities as determined by the health officer. 1001.3 Structural Hazards. Buildings or portions thereof shall be deemed substandard when they are or contain structural hazards. Structural hazazds shall include, but not be limited to, the following: 1. Deteriorated or inadequate foundations. 2. Defective or deteriorated flooring or floor suppor[s. 3. Flooring or floor supports of insufficient size to carry imposed loads with safety. 4. Members of walls, partitions or other vertical suppor[s that spli[, lean, lis[ or buckle du ro defective material or deteriorations. 5. Members of walls, paRitions or other vertical supports that are of insufficient size [o carry imposed loads with safety. 6. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that sag, split or buckle due to defec[ive material or deterioration. 7. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that are of insufficien[ size to carry imposed lads with safety. 8. Fireplaces or chimneys that list, bulge o settle due to defective material or deterioration. 9. Fireplaces or chimneys that aze of insufficient size or sVength to carry imposed loads wi[h safety. 1001.4 Nuisance. Buildings or portions thereof in which there exists any nuisance as defined in this code aze deemed substandard buildings. 1001.5 Hazardous ElecVical Wiring. Electrical wiring that was ins[alled in viota[ion of code requirements in effec[ at [he time of installation or elec[rical wiring not ins[alled in accordance wi[h generalty accepted consvuction practices in areas where no codes were in effect or that has not been maintained in good condition or that is no[ being used in a safe manner shall be considered substandard. 1001.6 Hazazdous Plumbing. Plumbing that was installed in viola[ion of code requirements in effect a[ the time of installation or plumbing not installed in accordance with generally accepted construction practices in ueas where no codes were in effect or that has no[ been maintained in good condition or that is not being used in a safe manner shall be considered substandard. 1001.7 Hazardous MechanicaL Mechanical equipment that was installed in viola[ion of code requirements in effect at the time of installation or mechanical equipment not installed in accordance with generally accepted construction practices in areas where no codes were in effect or that has not been maintained in good condition or that is not being used in a saFe manner shall be considered substandard. 1001.8 Faulty Weather Protections. Buildings or portions thereof shall be considered substandard when they have faulty weather protections, which shall include, but not be limited to, the following: 1. Deteriorated, crumbling or loose plas[er. 2. De[eriorated or ineffective waterproofing or exterior walls, roof, founda[ions or floors, including broken windows or doors. 3. Defective or lack of weather protec[ion for exterior wall coverings, including lack of paint, or wea[hering due to lack of paint or other approved protec[ive covering. 4. Broken, rotted, split or buckied exterior wall coverings or roof coverings. 1001.9 Fire Hazard. Any building or por[ion thereof, device, appaza[us, equipment, combustible was[e, or vegetation [hat, in the opinion of the chief of the fire department, is in such a condition as ro cause a fire or explosion or provide a ready fuel [o augment the spread and intensity of fire or explosion azising from any cause shall be considered substandard. 1001.10 Faulty Materials of Construction. The use of materials of consvuction, except those that aze specifically allowed or approved by [his wde and the Building Code, and [hat have been adequately maintained in good and safe conditions, shall cause a building to be substandard. 1001.11 Hazardous or Insanitary Premises. The acwmulation of weeds, vegetation, junk, dead organic matter, debris, garbage, offal, rat hazborages, stagnant water, combustible materials, and similar materials or conditions on a premises constitutes fire, health or safety hazards that shall be abated in accordance with the procedures specified in Chapter 11 of this code. 100112 Inadequate Exits. Except for those buildings or portions thereof that have been provided with adequate exit facili[ies conforming to the provisions of this code, buildings or portions thereof whose exit facilities were installed in violation of wde requiremen[s in effect a[ [he time of [heir construction or whose exit facilities have not been increased in number or width in relations ro any increase in occupan[ load due to alterations, additions or change in use or ocwpancy subsequen[ ro the time of construction shall be considered substandard. Notwithstanding compliance with code requirements in effect at the time of their consvuction, buildings or portions thereof shall be considered substandard when the building official finds that an unsafe condition exists through an improper location of exi[s, a lack of an adequate number or width of exi[s, or when other condi[ions exist [ha[ are dangerous to human life. 1001.13 Inadequate Fire-Protection or Fire-Fighting Equipment. Buildings or portions there of shall be considered substandard when they aze not provided with the fire-resistive construction or fire- extinguishing systems or equipment required by this code, except those buildings or portions thereof that conformed with all applicable laws at [he time of their construction and whose fire-resis[ive in[egrity and fire-extinguishing sys[ems or equipment has been adequately maintained and improved in relation ro any increase in occupant load, alteration or addition, or any change in occupancy. 100114 Improper Occupancy. All buildings or portions thereof occupied for living, sleeping, cooking or dining purposes that were not designed or intended ro be used for such ocwpancies shall be considered substandard. The following is a list of items that shall be fixed to meet code: ✓ The apartment unit shall be gutted to get out the smell of smoke. ✓ If sheet rock is removed then wiring and plumbing that is exposed shall be brought up to code. ✓ All items that have been modified shall meet code 2003 IBC. ✓ Smoke detectors shall be hardwired in with battery back up. ✓ City of Wheat Ridge Building permit shall be pulled before any demolition begins. ORDER The City of Wheat Ridge Building Official has determined the building referenced above to be a Dangerous Building and to constitute a health hazard if not fixed. The owners are ordered to pull a building permit to fix the deficient items. Pursuant to Code tenants shal] not be permitted to occupy this units until all issues are brought up to code and are inspected by the City of Wheat Ridge Building Department. This is therefore required in order to protect life, health and safety of the public. The property owner and all future occupants are hereby ORDERED TO CEASE AND DESIST occupancy and use of the above described building. The Building Official shall cause the property to be posted with the attached Notice and shall take action to remove a11 future occupants from the building. REMEDIAL ACTION 1. The property owner must apply for and obtain a City of Wheat Ridge building permit to correct the following deficiencies. 1. All deficiencies shall be fixed but aze not limited to the items on this list. APPEAL OF THIS NOTICE AND ORDER Any person having record title or other legal interest in the above described premises may appeal this Notice and Order or any action of the Building Official to the Board of Appeals pursuant to section 205 of the Code, provided that the appeal is made in writing as provided in the Code and filed with the Building Official within ten (10) days from the date of service of this Notice and Order. Failure to appeal will constitute a waiver of all rights to an administrative hearing and determination oF this matter. FILING OF AN APPEAL SHALL NOT STAY THE EFFECTIVENESS OF THIS NOTICE AND ORDER. It is a misdemeanor to occupy this building, or to remove or deface this notice. BY ORDER OF THE CITY OF WHEAT RIDGE'S BUILDING OFFICIAL 303-235-2853 303-570-7510 Chadley Root, Building Official Property appraisal system Previous 5 OF 24 Next Page 1 of 1 IISch:085144 Parcel ID:39-153-16-005 Status:Exemnt Pronertv Tvne:Exemrotl I W 48TH AVE kT RIDGE CO 80033 W 38TH AVE kT RIDGE CO 80033 Name COUNTY HOUSING sion Name: 243800 Date Location Map/Additional Information Send mnil to nssessoi@cajeCferson.co.us with questions or wmments about this Web site. Copyright @ 2004, Jefferson County, Colorado. All righ[s reserved. A Map of Ho_w to Get to Our Office Web site infolmation current through:04-0?-?005 Version 322 - Release Dare: Dec 2004 http://wwl4.co.jefferson.co.us/ats/displaygeneral.do?sch=085144&offset=4 4/5/2005 Home C:eneral prop9fty, Ft~~r~ds Iaiform.~i#it~n Y.`Building Permit CITY OF WHEAT RIDGE 7500 West 29TH Avenue . Wheatridge, CO 80033 , 303-235-2855 Cilyo(VMzattuye Permi[ Number 18972 7/13/2005 r Inspection Line 303-234-5933 Residential Miscellaneous !PROPERTY 9295 48th AV Ullll: pJ 1 QWNER: Jefferson County Housing Authority (303) 422-8600 :Deseriptiou Fice ROStocation: replace drywall, repair elect., repair plumbing, ceplace 1 heat register, replaee 1 window. _ I.. Due _ ~$.00 I$.00 _ [Paid _I tS ~Uaiht~Occupancy: Walls: Roof: Stories: SqFeet: 0 [ hbabymlify Nrt Ne setback Jislnnccs propased by Ihis permil appLcatlon ere aaunt4 antl da nol violale appYCable oNmances, rvkv or regula4om o(fhe Gry af I WYUtRiB[toreoveomm, e.xmente or rnln<aon. ofrcrord, [hat all mevsunmenls showq vnd allegafons made nre aauratt.luet 1 ha.'e revtl and+grn la abide by 1tl {oMltlppe prinhd on tM1is appLwfbw, and eM1nl l nssume full respnnsibllily for cumpllaocc mth ihe WM1em RiJge BuJdmg Cada (U.B C.) nnd nll olher apPlicable ~ Whep rdinmca,forwarkun ' ermtl. s o sIcrvEn nare 1 7ys permHwanesuedinvmorJancewtlM1thaprovtsionsx1 furthinyourapplicvtlonandissubject roIM1ebwsoftheSmaeo(ColondaenArodoeZoning IqeditlonemJfluikingCOdeo(WhealRidge,ColarvtloornnyolhvapphcableordmencevofdM1eCiry. ' 3 ,1%1epermitsha0<xyirei[(A)theworkeuthodu0ienalcommeneedwhM1insixty(60) tlaysfromissuetlehor(B)IM1ebuildingnutborizeJBSUSpmdedor .:`.d+naoomm, .n<.maon:oaays. D .IhWpermitexpiref.anewpermummbeacquireJfar. feeofoneM1nl(1heamounlnormvllyrtqukeJ,providednochangeshnvebnnorwNbemadcmMe oel(4ulpluwandspecNuhoneantlnnymsprnslo^orabvnJanmenthesmtexceedeeone(1)yenelfchnngesarematleonfsuspensiooorabvn0onmmt eseeed, om (q yevq PoII fees shall bc paiJ far a new permit. 4.No MOrkohnymmnersM1allbeJOmthat wNahangethenvNnlOOwafwattra.usingvdrallnvgeproblem S CMtraftor fhW mlify the Bu110ing Insyeawr Iwmry-four (24) honrs m advnnce for all iveyeatlons vnd shnll recdve wntlen npprovvl on inspecuon wN be6re p(uudin hmacoerve eua[t~Jab. ~ 6 af ~carlbeapP~^velaf ingsvndspeci0evliansfhvllsmlbeeonsvuMlobeayenm[far,noranapprovalof,nnyvlolationoftM1e ml~od olherordmance,law ruleorregulaUUn C61ef]olWio( Wpector $IGNED DATE ,:WedneYday, 7uly 13, 2005 Page 1 of 1 Building Permit CITY OF WHEAT RIDGE 7500 Weat 29TFI Avenue Wheatridge, CO 80033 303-235-2855 Cily af 4iheat F3dge~ I Permit Number 18972 7/13/2005 Inspection Line 303-234-5933 Residential Miscellaneous PROPERTY 9295 48th Av Unit: owNea: Jefferson County Housing Authority (303) 422-8600 Description Fire Restoration: replace drywall, repair elect., repair plumbing replace 1 heaY register, replace 1 window. Authorized By guilding Approval Zoning Authorized On Approved By CR Must meet 2003 IBC, 2002 NEC Wednesday, July 13, 2005 Page 1 of 1 COMMUNITY DEVELOPMENT DEPARTMENT Building Pertnit Number: a'""f+T BUILOING INSPECTION UNE - 303-234-5933 Date: ° °a CITV OF WHEAT RIDGE ~ ^ 7500 WEST 29TH AVENUE WHEAT RJDGE, CO 60033 - (303-235-2855) ~o~«~.~ APPLICATION - rroperrY owner: . rnoot: 3cie AfzX-BGCnntxs PropcrtY wadress: g Conaactor Liccnse No.: Pbone' ~03 yJ37 -07/~(l~.Z! t ~~y: co pWNEWCONTiUCTOR SIG7UTURE OF UNDERSTANOING AND AGREEMENT Buildina Dept Valuation Figure: 1 hereby ceAifY that the SetDack distances MWoSOO bY Mis Pemit appfication are accurate. ard do rwt violate aPWicaDk aanances, rules a repuWtions of the Ciry ot Wheat Ri(ipe a oovenants. easertients a restricGOns of record: Cwt all meawremd" shown. ard aNeflauons made are aau2le: tlwt 1 have read and aGree to abide bY all conditions Mi^ted on this appliwtion and that I aswme wu resv«+siaxry ta compiiance with the W heat Ridpe &ri1d+rW CoOe (I.B.C) an0 aN Wher aPPlicable Wheat Ridpe Ordinances, for work un0a this permil. Plans subject to fieW inspec0on. DATE7"~ (OW NFRNGONTRACTOR). SIG Onh (OW NEi1)(GONTfiACTOR):P1iNRED Value:5 ~a / Permit Fee:$ ~ ~ Plan Reviewce Tee:S~~° ~ Total:$ lfse of Space (description): Desc_ ^ ~pticnif~ q~p77 ~,~i~~~ ~w~~mcFiA'u~t~'a~' `u~uii t~P"c~ it~aor~a`~u. - ' l V SQ.Ft.added r' 0 BUII.DING DEPARTMEI`17' USE ONLY SIC: Sq.FI: WING COIMAENTS: qpproval: Zoniry: Cify vf Wheat Rid e PRESCRIPTiVE ENER Y t~ 200§ maNCCOw+ewTS. BOILERS : FURNACES A MINIMUM OF 90% FUE Mu~~~ Qp$ WATER HEATERS A MINIMUM OF.60 ENER- _ a LECTRIC WATER HEATERS A DAINIMUM OF.93 ENERGY FACTOR SFG ~ 3 +eNTS: Cau ~ $ETBACK THERMOS'CAT REQUIRED (EXCEPT HYDRONIC HEAT) . aKs jeucwo Approval: R.21 yypLl.S • R-38 CEILINGS • R•19 CRAWISPACES Deo,wnWM CawMENrS: qpppvai: yyalls; Roof: t~i t~~ ~ Plumbing License EfectncaI L'wense C~ Grt~. ° Company. A Company. Expiration Date: Exp~p~ir~aytion Oate: w.....ma~l• ' T~' _ _ _ . Stories: Residentiai Units: Mechanical L'icense ' Company. ~ ~ Expiration Date: dsnoe wM the P~^~^s ~ IoM in your appGraUOn arW is wbjea b the laws ot tne State of (1) 7Tis P~ was iuued in xaor Cp1"dp and b Mx ZaWq Repulsoaa ard BuiW'mG Codes d Wheat RiOpe. Cdaado a anY otlw oVdicable ord'mances of Me CeY• atuY e~ro d(A) G~e work auUwrmed is nd commenoeC ~hv~ sintY (90) 0aYs fia" issue date a(8) the building {2) Thau~ a wpsnded a ypyKiybp for a Geriod of 180 days. (3) If tltia P~~ ~roE. a new D~^K ~^aY b° 1or a fee o1 ons-haM 1M arnourn normagN ro0uiieC. pwided no dha^9es nave ceen wwiM De maas in n» oripinal WYW wo p°Otimcons arw anr wa0ermo^ °f oba'xw'mw" nas not exceeeed one (1) Yege. H chypey havs bsen a H swDons°^ °f °bww0rwnwd O1ceeds one (1) Y'ear. tuB fees shall bs Daw iv a new Demril- (4) No wak d anY ^urwW sha W Oais Uul vA d+rqs IM ruWrallbw d wabr mdrW a drairupe po61eni. IM &idrq knD~ t+'~Y~r (24) ~m in advarws lor 91 ~ and aheR recerve writlen ConVacbw (5) appmval Y~i~ps ~ db^ cord baiors Woopedr'0 wih wcosseiw Whass+ d IM job. 16) The is,uanw d a Dw" ar sw &vRoval ddr""""o° and °p°dkobons " na be ca,atrued m be a vwma tor. rwr an appwal d. anY vblmlio^ d 1M Wovbb^° of tlw buNdmp ooEes w anY oCw adnanoe. Uw. mb v rePtlaOO^- N1 Wn rwMw b wblect lo }Mid Mupw-Uom• Chief BuiWing Official Disaster Solutions 7130 West 16th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 Client: JCHA-Henry Wehrdt Cellulaz: (303) 994-3034 Fax: (303) 422-8600 Property: 7490 W 45th Avenue Businesx (303) 422-8600 Wheatridge, CO 80033 Operator Info: Operator. DENNIS Estimator: Dennis Newell Business: (303) 937-0717 x 1 r oi ~nea~ n '_"R~RIPTIVE ~NERGY Business: 7130 West 16th Avenue gpILERS 1 FURNACES A MINIMUM OP 90% AFUE Lakewood, CO 80214 a" yyATER HENTERS A MINIMUM OF.i0 ENERGY FACTOR ~ yyATER HEATERS A MINIMUM OF.89 ENERGY FACTOR Type of Estimate: Fire ~ CK THERW sTAT REQUIRED (EXCEPT HYDRONIC FIEAT) Dates: R-21 yALI,s . p41 CHIJM65 • R•19 CRAYrLfPAM Date Entered: 04/29/05 Date Assigned: 04/06/05 Price List: MARCH2005 Restoration/Service/Remodel with Service Chazges Factored In Estimate: JCHACAESARSQUARE File Number: 9295W48THAVE Claim#A6TR8 ON SITE PLANS Eagle Adjusting Services, Inc. Adj: Brian Kramp P. B°X'Z'° MUST BE ON SITE Pazker, CO 80134 P,-,:303_805_1205 FOR INSPECTION ~WH~•>,,, CHIEF BUILDING OFFICIAL Wheat Ridge BuildinqyDepartment f ~,,./T • a L J LDING OFFI IAi. - DA1'E validity of perm0: 76 iewanoe d a penmit a aDproval c( Plans, speaficatw^s 3nd tampulations shaN ial be a permit tor, a en approvel d, airy vblation to any d Ihe provisions oi the ddldrg oode or d any City ordnances. PBrmMs Oresuming Io give aulhaNy to vblale or cancel the provisians dtBe - Iwildij wdes or other wdinances d the Ciry shaN not be valid. Disaster Solutions 7130 West 16th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 Room: Living Room JCHACAESARSQUARE LxWxH 14'6" x 12'2" x 7'4" R&R Door opening (jamb & casing) - 32"to36"wide - paint grade 1.00 EA Interior door - Detach & rese[ - slab only 1.00 EA R&R Carpet - Standard grade 176.42 SF R&R Carpet pad 176.42 SF R&R Carpet - metal transition strip 6.00 LF R&R Acoustic ceiling (popcorn) texture 176.42 SF Clean the walls - Heavy 301.89 SF SeaVprime the walls - one coat (white pigmented shellac) 301.89 SF Paint the walls - two coats 301.89 SF Mask the walls per squaze foot 301.89 SF Clean window unit (per side) 10 - 20 SF 1.00 EA Clean baseboard heater 12.00 LF Paint baseboard heater 12.00 LF Clean exterior door (per side) 2.00 EA Clean door / window opening (per side) 1.00 EA Clean outlet or switch 6.00 EA Clean thertnostat 1.00 EA R&R Window screen, 1- 9 sf 1.00 EA Clean and deodorize building - Ozone treatment 150.00 CF R&R Smoke detector - High gade 1.00 EA Waste Item - Carpet - Standazd grade 44.83 SF Waste Xpert - Carpet Waste: The following cuts will produce the specified line item prices: Cut #1 Room Name: Living Room Dimensions 14'9" X 12'0" Cut #2 Room Name: Living Room D'unensions: 3'8" X 1'8" Room: Kitchen LxWxH 12'2" x 11'0" x 7'4" Clean floor, strip & wax R&R Fluorescent light fixture R&R Ceiling fan & light Clean cabinetry - upper - inside and out Clean cabinetry - lower - inside and out 133.83 SF 1.00 EA 1.00 EA 20.00 LF 15.00 LF JCHACAESARSQUARE 07/05/2005 Page: 2 Disaster Solutions 7130 Westl6th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 CONTINUED - Kitchen R&R Coun[ertop - post formed plastic laminate 12.50 LF Clean range hood 1.00 EA Clean dishwasher 1.00 EA Clean the walls and ceiling - Heavy 384.39 SF Seal/prime the walls and ceiling - one coat (white pigmented shellac) 38439 SF Paint the walls and ceiling - two coats 38439 SF Mask the walls per square foot 250.56 SF Sink - double - Detach & reset 1.00 EA Clean sink 1.00 EA Clean sink faucet 1.00 EA Clean outlet or switch 6.00 EA Clean kitchen accessory 1.00 EA Clean range - Heavy 1.00 EA R&R Refrigentor - 14 cf 1.00 EA Clean and deodorize building - Ozone treahnent 150.00 CF R&R Smoke detector 1.00 EA Room: Hallway Subroom 1: Closet LxWxH 97" x 3'4" x 7'4" LxWxH 5'6" x 2'3" x 7'4" R&R Carpet R&R Cazpet pad R&R Carpet - metal transition strip R&R Acoustic ceiling (popcorn) texture Clean the walls - Heary SeaVprime the walls - one coat (white pigmen[ed shellac) Paint the walls - two coats Mask the walls per square foot R&R Smoke detector 4432 SF 44.32 SF 6.00 LF 4432 SF 198.00 SF 198.00 SF 198.00 SF 198.00 SF 1.00 EA JCHACAESARSQUARE 07/05/2005 Page: 3 Disaster Solutions 7130 West 16th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 CONTINUED - Hallway R&R Bifold door set - Birch veneer - Double 1.00 EA Stain & finish bifold door set - slab only -(per side) 2.00 EA R&R Interior door - lauan/mahogany - pre-hung unit-for both bedrooms 2.00 EA R&R Door lockse[ - interior-both bedrooms 1.00 EA Stain and finish door slab only (per side) 6.00 EA 1.00 EA Clean light fixhue 28.00 LF Clean shelving - wood Seal & paint wood shelving 12"- 24" width 28.00 LF Clean and deodorize building - Ozone treatrnent 150.00 CF Room: Bathroom (full) LxWxH 8'6" x 5'6" x 7'4" .75 SF 46 Clean floor, strip & wac 1.00 EA R&R Light baz - 3 lights 5.00 LF Clean vaniry - inside and out R&R Countertop - post formed plastic laminate 5.00 LF 252.08 SF Clean the walls and ceiling - Heavy Seal/prime the walls and ceiling - one coat (white pigmented sheliac) 252.08 SF 252.08 SF Paint the walls and ceiling - rivo coats 20533 SF Mask the walls per squaze foot 1.00 EA Sink - single - Detach & reset 1.00 EA Clean sink 3.00 EA Clean sink faucet 2.00 EA Clean outlet or switch 4.00 EA Clean bath accessory 1.00 EA Clean medicine cabinet - Large R&R Interior door - lauan/mahogany - pre-hung unit 2.00 EA 1.00 EA R&R Door lockset - interior Stain and fnish door slab only (per side) 2.00 EA 1.00 EA Clean toilet JCHACAESARSQUARE 07/05/2005 Page: 4 Disaster Solutions 7130 West 16th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 CONTINUED - Bathroom (full) R&R Toilet seat 1.00 EA Clean baseboazd heater 5.00 LF Paint baseboazd heater 5.00 LF Clean ceramic tile 50.00 SF Scrape and regrout tile 50.00 SF Clean window unit (per side) 10 - 20 SF 1.00 EA Clean door / window opening (per side) 1.00 EA Clean shower door 2.00 EA Shower door - slab only - Detach & reset 1.00 EA Clean and deodorize building - Ozone treatment 150.00 CF Room: Bedroom-1 Subroom 1: Closet LxWxH 12'0" x 10'10" x 8'0" LxWxH 8'6" x 2'3" z 7'4" R&R 5/8" drywall - hung, taped, floated, ready for paint Acoustic ceiling (popcom) texture Texture drywall - machine Seal then paint the walls and ceiling twice (3 coats) Seal stud wall for odor control Mask the walls per square foot Rewire - Bid Item R&R Interior door - lauan/mahogany - pre-hung unit R&R Door lockset - interior Stain and finish door slab only (per side) R&R Light fixture - High grade R&R Bifold door set - lauan/mahogany - Double Stain & finish bifold door set - slab only -(per side) Stain & finish door/window trim & jamb - Large (per side) R&R Light fixture JCHACAESARSQUARE 574.13 SF 149.13 SF 425.00 SF 574.13 SF 425.00 SF 425.00 SF 1.00 EA 1.00 EA 1.00 EA 2.00 EA 1.00 EA 1.00 EA 2.00 EA 2.00 EA 1.00 EA 07/05/2005 Page: 5 Disaster Solutions 7130 West 16th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 CONTINUED - Bedroom-1 R&R Aluminwn window, horiz. slider 12-23 sf (2 pane) 1.00 EA R&R Baseboazd heat - steam or hot water 12.00 LF R&R Closet shelf and rod package 8.50 LF Paint - closet package (shelf, jamb & casing) 1.00 EA R&R Carpet 149.13 SF R&R Carpet pad 149.13 SF R&R Smoke detector - High grade 1.00 EA Clean and deodorize building - Ozone treahnent 150.00 CF Waste Item - Carpet 51.06 SF Waste Xpert - Cazpet Waste: The following cuts will produce the specified line item prices: Cut 41 Room Name: Bedroom-1 Dimensions: 11'1" X 12'0" Cut 42 Room Name: Closet & Closet Dimensions: 4'5" X 10'0" Cut #3 Room Name: Hallway Dimensions: 4'11" X 7'2" Room: Bedroom-2 Subroom 1: Cbset General clean - up Clean and deodorize building - Ozone treahnent R&R Interior door - lauan/mahogany - pre-hung unit R&R Door lockset - interior Stain and finish door slab only (per side) LxWxH 12'0" x 10'10" x 8'0" LxWxH 8'6" x 2'3" x 7'4" 1.00 HR 150.00 CF 1.00 EA 1.00 EA 2.00 EA JCHACAESARSQl1ARE 07/05/2005 Page: 6 Disaster 7130 West 16th Avenue Lakewood, CO 80214 PH303-937-0717 FAX-303-922-6902 R&R Smoke detector - High gade 1.00 EA Room: Hallway LxWxH 30'0" x 8'0" x 8'0" Subroom 1: Offset LxWxH 9'0" x 3'0" x 8'0" Clean and deodorize carpet - heavy staining 267.00 SF R&R Stud wall - 2" x 4" - 16" oc 64.00 SF R&R 5/8" drywall - hung & fire taped only 128.00 SF Room: General Dumpster load - Approx. 30 yards, 5-7 tons of debris 1.00 EA Taaces, insurance, permits & fees (Bid item) 1.00 EA Grand Total `iFr3.4#2 47 Dennis Newell JCHACAESARSQUARE 07/05/2005 Page: 7 ~ a w = 5.2 ~ y V Z > W Q ~ ~ a ~W) Z O ~N ~ W ~M O W ~N No oV) ~ F V L 4) _ V ~ N 0 U ~ N N d ~ V Q ~ O ~ L R 0 %P a N C ~ w ~ ~ ~ ~ ~ c a > m t c c w c a ~ C C L M R ~ MI ~