HomeMy WebLinkAbout9295 W 48th Avenue� ► 44" City of Wheat Ridge
'/� Commercial Remodel PERMIT - 202100276
PERMIT NO: 202100276 ISSUED: 06/17/2021
JOB ADDRESS: 9295 W 48th Ave N EXPIRES: 06/17/2022
JOB DESCRIPTION: Caesar Square - Building 5 Complete interior and exterior building
renovation - 21,785 sq ft total
*** CONTACTS ***
OWNER (720)766-1095
JEFFERSON COUNTY HOUSING AUTHO
GC ( 3 0 3) 928-1800
SCOTT M. KOHRS
020534 TAYLOR KOHRS , LLC
SUB (970)490-1458
BARB RAUS CH
160004 AI R COMFORT, INC.
SUB (303) 936-7924
BRAD CHRISTIANSON
080241 RYCH ELECTRIC INC
SUB (970)221-1735
BRANDY JONES
202075 LIND'S PLUMBING & HEATING INC
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE: UA / Unassigned
SUBDIVISION CODE:
103 /
BLOCK/LOT#: 0 /
*** FEE SUMMARY ***
ESTIMATED PROJECT VALUATION:1,214,724.00
FEES
Total Valuation
0.00
Plan Review Fee
41773.31
Permit Fee
71343.55
** TOTAL **
12,116.86
*** COMMENTS ***
*** CONDITIONS ***
Approval from presiding fire department required prior to final building inspection
sign -off.
All roughs to be done at Framing Inspection.
A printed copy of the permit and city stamped on-site plans must be available on-site for
the first inspection.
Approved per plans and red -line notes on plans. Must comply with 2018 IBC, 2020 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
**Prior to final inspection approval - As-builts are required before approval of the
Building Final Inspection and Certificate of Occupancy can be issued.
1* � 4 41'
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
Commercial Remodel PERMIT - 202100276
202100276
9295 W 48th Ave N
Caesar Square - Building 5 Complete
renovation - 21,785 sq ft total
ISSUED: 06/17/2021
EXPIRES: 06/17/2022
interior and exterior building
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
06/17/2021
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: Residential Interior Remodel
Date: Friday, February 12, 20219:39:13 AM
Residential Interior Remodel
This application is exclusively for Residential Interior Remodels and other scopes
of work which do not have a specific form already available.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Property Address 9295 W. 48th Ave
Property Owner Name
Foothills Regional Housing (Formerly Jefferson County Housing
Authority)
Property Owner Phone
720-766-1095
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
akloke@foothillsrh.org
Address
Attach City of Wheat
Electronic Payment Form.odf
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
APPLICANT INFORMATION
Applicant Name Studio 646 Architecture
What is your role in the Architect
project?
Contact Phone Number 720-297-9416
(enter WITH dashes,
eg 303-123-4567)
Contact Email Address eblase@646arch.com
for Plan Review
Comments
Retype Contractor eblase@646arch.com
Email Address
DESCRIPTION OF WORK
Detailed Scope of
Caesar Square Apartments is a renovation project of 108
Work - In the space
apartment units within 5 buildings located in Wheat Ridge,
below (not as an
Colorado. This property is managed and maintained by Jefferson
attachment), Provide a
County Housing Authority as an affordable housing project in the
detailed description of
Metro -Denver area. The buildings were originally built in the early
work Including
1970's, and have experienced minor renovations over the yars.
mechanical, electrical,
The scope of this project includes site renovation, reconstruction
plumbing work
and reconfiguration of the parking area, addition of site
amenities, construction of a new construction community center,
occurring,
and renovation of the residential unit interiors and exteriors of the
adding/removing walls,
five existing apartment builings.The overall scope also includes
etc
adding accessibility for those with mobility impaiments. The new
commnity building will be constructed as a fully accessible
building, and buildings 2 and 3 will be renovated to allow for
accessible entry to he buildings, as well as have unit modifie to
comply with ANSI Type'A' requirements. This set of documents
in only a documentation of the renovation scope for building 3
wih scope items summarized below. BUILDING 3 RENOVATION
SUMMARY: 1" = 60'-0" BUILDING 3 - SITE PLAN - PROPOSED
3 1. EXTERIORS a. Repaint existing siding b. Reclad mansard
roofs with metal c. Bring stairs / railings up to code d. Add
exterior building signage e. Add exterior ramp on north side into
building for accessibility. f. Add accessibility modifications at
exterior of building. g. Replace exterior sliding windows with
casement windows at Type'A' units on level 1. 1. INTERIORS -
UNITS a. Asbestos abatement at floors & drywall at bathrooms b.
Type'A' Unit modifications c. Replace all new unit entry doors /
hardware d. Replace all bath plumbing fixtures / accessories /
shower valves e. Replace all kitchen cabinets / plumbing fixtures
/ appliances / accessories f. Replace all lighting g. Update
electrical to code / pig -tailing aluminum wiring h. Repaint all unit
interiors: walls / ceilings / shelving / sills / frames i. Replace all
unit interior flooring 2. INTERIORS — CORRIDORS a. Replace all
light fixtures b. Replace all interior stair railings c. Replace all unit
entry doors & add new accessible signage d. Repaint all corridor
walls / ceilings / trim e. Replace all corridor flooring f. Remove
existing window and door at all exterior building entries and
replace with aluminum storefront system
I, the applicant,
I have entered a detailed scope of work.
understand my
application will be
rejected if I do not
include a Detailed
Scope of Work.
Location of Work Entire building interior - New finishes
Square Footage Area
of Work Being
Performed
Asbestos Report
Upload letter size
documents here
Construction Plans
scanned on 11'x17" or
larger
Renovation - No new constuction s.f.
14 53 SEEM STZS rem • --
Field not completed.
2021-0211 Caesar Sauare Buildina 3 Undated Permit Set.odf
Project Value (contract 1,214,724 Valuation okay
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
Person Applying for eric blase
Permit
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Email not displaying correctly? View it in your browser.
SUBCONTRACTOR AUTHORIZATION FORM
Electrical Subcontractor
This form must be completed & signed by the ELECTRICAL SUBCONTRACTOR
performing electrical work on site.
Subcontractor's insurance and license must be up to date prior to permit issuance.
Project Address: 9235 - 9355 W. 48th Ave.
General Contractor: Taylor Kohrs, LLC
Company Name: Rych Electric Contact Phone #: 303.936.7924
Wheat Ridge Contractor License #:6'3ozly( (required field)
State License #: �C�7
Master License #: C3(aboc o
Printed Name of Authorized Agent
Si ure of Authorized Agent
/b _
Dat
DocuSign Envelope ID 135BF827-FA2D-4A98-9CD2-135439ED2C31
4'
City of
"�IT
Wheat�s,ge
COMMUNY DEVELOPMENT
SUBCONTRACTOR AUTHORIZATION FORM
Mechanical Subcontractor
TMs form must be completed & signed by the MECHANICAL SUBCONTRACTOR
performing mechanical work on site.
Subcontractor's insurance and license must be up to date prior to permit issuance.
Project Address: 9235 - 9355 W. 48th Ave.
General Contractor:
Company Name: Air Comfort Contact Phone #: 970.490.1458
Wheat Ridge Contractor License #:L60004 (required field)
Matt Rausch, Cluef Executive Officer
Printed Name of Authorized Agent
o-USigned by:
KaUSlIa. 7/13/20
Srgnaf`ure o uthorized Agent Date
f�AIt
Ir ctty of
Wh6atf �idge
COMMUNITY DEVELOPMENT
SUBCONTRACTOR AUTHORIZATION FORM
Plumbing Subcontractor
his fbrm must be ct signrbyrt
performing plumbing work on site.
Subcontractor's insurance and license must be up to date prior to permit issuance.
Project Address:
General Contractor:
L -,c
FORM WILL NOT BE ACCEPTED WITH MISSING INFORMATION
Company Name: L nd 5 �i)4 I iIC- Contact Phone #: R -7b—aa 1 ��
Wheat Ridge Contractor License #: T 0 (required field)
State License #:
M(
Com/ r-�
Master License #: D �� LD. J� J
14LI, 1 6 fflm(
Printed Name of Authorized Agent
z 1'ell
Signature of Authorized Agent
& � J 00@0
Date
i� �l/heat �l�e
APPROVED
Eavlawad W C:Otla CalInnhatte
kirkmoney 05/07/2021
Plans Lunrwr tats
�� 7ne trNeM ei r mov.* ew. u Okoi
mYeBgbt6MY.9JMtwlt Of.iN�'wrJlS.a+'en�atsnl C( trM luf.le"k
a� gPter Pa..bu e/ rkri.Jll,J, .v#.rc # aLF.rR erJ.ao•. lwam
rxw w, y».a,.or.i._W-1 to. (-o
o t•e{A.q
Square Apartments - Building 3 Summary
20 -Dec -19
Ear
ment Units
Sq.Ft.
I Basement
I Level 1
Level 2
Unit Total
Ratio
Sq.Ft. Total
1 Bedroom 3-1.1
61 1
01
11
0
1
- COVER SHEET
611
1 Bedroom 3-1.2
760
0
U
1
1
BLDG 3
760
1 Bedroom Subtotal
700
2
90%
1371
2 Bedroom 3-2.1
806
0
5
5
10
- COVER SHEET
8060
2 Bedroom 3-2.2
700
0
0
2
2
BLDG 3
1400
2 Bedroom 3-2.3-A
700
0
2
0
2
A3-103
1400
2 Bedroom 3-2.4
789
0
21
2
4
LINE INDICATES
3156
2 Bedroom 3-2.5
770
2
01
0
2
BLDG 3
1540
2 Bedroom Subtotal
BLDG 3
20
91%1
15556
Unit Totals 21 101 101 22
Unit Net Sq.Ft. 16927
ffTFFFFFFM_FFMTM_M�
HUMN� UM" � � SIIF1 F F___F
i
w
o®V
HATCH INDIC,
SCOPE OF W
bUILDING 3 - SITE PLAN - EXISTING W. 48TH AVENUE
1" = 60'-0"
L_
F71 11 1 1&76,1 1 1 1 1
0
LNC
W. 48TH AVENUE
BUILDING 3 - SITE PLAN - PROPOSED
1" = 60'-0"
n
PROJECT NARRATIVE:
Caesar Square Apartments is a renovation project of 108 apartment units within 5 buildings located
in Wheat Ridge, Colorado. This property is managed and maintained by Jefferson County Housing
Authority as an affordable housing project in the Metro -Denver area.
The buildings were originally built in the early 1970's, and have experienced minor renovations over
the yars. The scope of this project includes site renovation, reconstruction and reconfiguration of
the parking area, addition of site amenities, construction of a new construction community center,
and renovation of the residential unit interiors and exteriors of the five existing apartment
builings.The overall scope also includes adding accessibility for those with mobility impaiments. The
new commnity building will be constructed as a fully accessible building, and buildings 2 and 3 will
be renovated to allow for accessible entry to he buildings, as well as have unit modifie to comply
with ANSI Type 'A' requirements.
This set of documents in only a documentation of the renovation scope for building 3 wih scope
items summarized below.
BUILDING 3 RENOVATION SUMMARY:
1. EXTERIORS
a. Repaint existing siding
b. Reclad mansard roofs with metal
C. Bring stairs / railings up to code
d. Add exterior building signage
e. Add exterior ramp on north side into building for accessibility.
f. Add accessibility modifications at exterior of building.
g. Replace exterior sliding windows with casement windows at Type 'A' units on level 1.
1. INTERIORS - UNITS L
a. Asbestos abatement at floors & drywall at bathrooms
b. Type 'A' Unit modifications
C. Replace all new unit entry doors / hardware
d. Replace all bath plumbing fixtures / accessories / shower valves
e. Replace all kitchen cabinets / plumbing fixtures / appliances / accessories
f. Replace all lighting
g. Update electrical to code / pig -tailing aluminum wiring
h. Repaint all unit interiors: walls / ceilings / shelving / sills / frames
i. Replace all unit interior flooring
2. INTERIORS — CORRIDORS
a. Replace all light fixtures
b. Replace all interior stair railings
C. Replace all unit entry doors & add new accessible signage
d. Repaint all corridor walls / ceilings / trim
e. Replace all corridor flooring
f. Remove existing window and door at all exterior building entries and replace with
aluminum storefront system
IL1I11WX•1a11ZIAT jIL1[cl-�
Sheet No.
WHEAT RIDGE APPLICABLE CODES:
E
THESE PLANS WERE REVIEWED PER THE STANDARDS IN E
THE CITY OF WHEAT RIDGE ADPOTED CODES AND E
AMENDMENTS IN PLACE AT THE TIME OF APPLICAITON. E
Sheet Name
BUILDING 3 -ARCHITECTURAL
A3-001
BLDG 3
- COVER SHEET
A3-002
BLDG 3
- COVER SHEET
A3-003
BLDG 3
- ENTERPRISE GREEN COMMUNITIES CHECKLIST
A3-100
BLDG 3
- EXISTING FLOOR PLANS
A3-101
BLDG 3
- EXISTING FLOOR PLANS
A3-102
BLDG 3
- EXISTING ROOF PLAN
A3-103
BLDG 3
- OVERALL DEMOLITION FLOOR PLANS
A3-104
BLDG 3
- PROPOSED FLOOR PLANS
A3-105
BLDG 3
LINE INDICATES
A3-106
BLDG 3
-L
A3-301
BLDG 3
- ENLARGED UNIT 3-1.1 PHASING PLAN
ACCESSIBLE ROUTE
BLDG 3
- ENLARGED UNIT 3-1.2 PHASHING PLAN
A3-303
BLDG 3
- ENLARGED UNIT 3-2.1 PHASING PLAN
A3-304
TO LAUNDRY ROOM
- ENLARGED UNIT 3-2.2 PHASING PLAN
A3-305
BLDG 3
- ENLARGED UNIT 3-2.3 PHASING PLAN
A3-306
t
t
A3-307
BLDG 3
'
A3-308
BLDG 3
- ENLARGED UNIT 3-2.5 PHASING PLAN
—
BLDG 3
- ENLARGED UNIT 3-2.6 PHASING PLAN
A3401
BLDG 3
- EXISTING EXTERIOR ELEVATIONS
A3402
BLDG 3
- PROPOSED EXTERIOR ELEVATIONS
A3-601
BLDG 3
- RAMP & RAILING DETAILS
A3-602
BLDG 3
- RAILING DETAILS
A3-603
BLDG 3
- DETAILS
A3-604
BLDG 3
- DETAILS
A3-
BLDG 3
-WALL ASSEMBLIES & DETAILS
A3-606
BLDG 3
- INTERIOR ACCESSIBILITY DETAILS
A3-607
BLDG 3
- MOUNTING HEIGHTS & ACCESSIBILITY DETAILS
A3-701
BLDG 3
- DOOR /WINDOW FRAME & TYPES AND SCHEDULES
�N
BLDG.3
-'
W
9295 W 48TH AVE,
w
W
22 UNITS �
�
F
W
LINE INDICATES
-
ACCESSIBLE ROUTE
TO TYPE'A' RESIDENT
STORAGE
W. 48TH AVENUE
BUILDING 3 - SITE PLAN - PROPOSED
1" = 60'-0"
n
PROJECT NARRATIVE:
Caesar Square Apartments is a renovation project of 108 apartment units within 5 buildings located
in Wheat Ridge, Colorado. This property is managed and maintained by Jefferson County Housing
Authority as an affordable housing project in the Metro -Denver area.
The buildings were originally built in the early 1970's, and have experienced minor renovations over
the yars. The scope of this project includes site renovation, reconstruction and reconfiguration of
the parking area, addition of site amenities, construction of a new construction community center,
and renovation of the residential unit interiors and exteriors of the five existing apartment
builings.The overall scope also includes adding accessibility for those with mobility impaiments. The
new commnity building will be constructed as a fully accessible building, and buildings 2 and 3 will
be renovated to allow for accessible entry to he buildings, as well as have unit modifie to comply
with ANSI Type 'A' requirements.
This set of documents in only a documentation of the renovation scope for building 3 wih scope
items summarized below.
BUILDING 3 RENOVATION SUMMARY:
1. EXTERIORS
a. Repaint existing siding
b. Reclad mansard roofs with metal
C. Bring stairs / railings up to code
d. Add exterior building signage
e. Add exterior ramp on north side into building for accessibility.
f. Add accessibility modifications at exterior of building.
g. Replace exterior sliding windows with casement windows at Type 'A' units on level 1.
1. INTERIORS - UNITS L
a. Asbestos abatement at floors & drywall at bathrooms
b. Type 'A' Unit modifications
C. Replace all new unit entry doors / hardware
d. Replace all bath plumbing fixtures / accessories / shower valves
e. Replace all kitchen cabinets / plumbing fixtures / appliances / accessories
f. Replace all lighting
g. Update electrical to code / pig -tailing aluminum wiring
h. Repaint all unit interiors: walls / ceilings / shelving / sills / frames
i. Replace all unit interior flooring
2. INTERIORS — CORRIDORS
a. Replace all light fixtures
b. Replace all interior stair railings
C. Replace all unit entry doors & add new accessible signage
d. Repaint all corridor walls / ceilings / trim
e. Replace all corridor flooring
f. Remove existing window and door at all exterior building entries and replace with
aluminum storefront system
IL1I11WX•1a11ZIAT jIL1[cl-�
Sheet No.
WHEAT RIDGE APPLICABLE CODES:
E
THESE PLANS WERE REVIEWED PER THE STANDARDS IN E
THE CITY OF WHEAT RIDGE ADPOTED CODES AND E
AMENDMENTS IN PLACE AT THE TIME OF APPLICAITON. E
Sheet Name
BUILDING 3 -ARCHITECTURAL
A3-001
BLDG 3
- COVER SHEET
A3-002
BLDG 3
- COVER SHEET
A3-003
BLDG 3
- ENTERPRISE GREEN COMMUNITIES CHECKLIST
A3-100
BLDG 3
- EXISTING FLOOR PLANS
A3-101
BLDG 3
- EXISTING FLOOR PLANS
A3-102
BLDG 3
- EXISTING ROOF PLAN
A3-103
BLDG 3
- OVERALL DEMOLITION FLOOR PLANS
A3-104
BLDG 3
- PROPOSED FLOOR PLANS
A3-105
BLDG 3
- PROPOSED FLOOR PLANS
A3-106
BLDG 3
- PROPOSED ROOF PLAN
A3-301
BLDG 3
- ENLARGED UNIT 3-1.1 PHASING PLAN
A3-302
BLDG 3
- ENLARGED UNIT 3-1.2 PHASHING PLAN
A3-303
BLDG 3
- ENLARGED UNIT 3-2.1 PHASING PLAN
A3-304
BLDG 3
- ENLARGED UNIT 3-2.2 PHASING PLAN
A3-305
BLDG 3
- ENLARGED UNIT 3-2.3 PHASING PLAN
A3-306
BLDG 3
- ENLARGED UNIT 3-2.4 TYPE A PHASING PLAN
A3-307
BLDG 3
- ENLARGED UNIT 3-2.4 TYPE A PHASING PLAN
A3-308
BLDG 3
- ENLARGED UNIT 3-2.5 PHASING PLAN
A3-309
BLDG 3
- ENLARGED UNIT 3-2.6 PHASING PLAN
A3401
BLDG 3
- EXISTING EXTERIOR ELEVATIONS
A3402
BLDG 3
- PROPOSED EXTERIOR ELEVATIONS
A3-601
BLDG 3
- RAMP & RAILING DETAILS
A3-602
BLDG 3
- RAILING DETAILS
A3-603
BLDG 3
- DETAILS
A3-604
BLDG 3
- DETAILS
A3-
BLDG 3
-WALL ASSEMBLIES & DETAILS
A3-606
BLDG 3
- INTERIOR ACCESSIBILITY DETAILS
A3-607
BLDG 3
- MOUNTING HEIGHTS & ACCESSIBILITY DETAILS
A3-701
BLDG 3
- DOOR /WINDOW FRAME & TYPES AND SCHEDULES
CITY OF
WHEAT RIDGE APPLICABLE CODES:
E
THESE PLANS WERE REVIEWED PER THE STANDARDS IN E
THE CITY OF WHEAT RIDGE ADPOTED CODES AND E
AMENDMENTS IN PLACE AT THE TIME OF APPLICAITON. E
EXISTING
E
APPLICABLE CODES:
2018 INTERNATIONAL BUILDING CODE (IBC) E
0
2018 INTERNATIONAL MECHANICAL CODE (IMC)
0
2018 INTERNATIONAL ENERGY CONSERVATION CODE E
3
2018 INTERNATIONAL RESIDENTIAL CODE (IRC) E
2
2018 INTERNATIONAL FIRE CODE E
0
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
5
2018 INTERNATIONAL EXISTING BUILDING CODE
0
2018 NATIONAL ELECTRICAL CODE (NEC)
STUDIO 646 ARCHITECTURE, LLC
2018 INTERNATIONAL PLUMBING CODE (IPC)
15940 S. GOLDEN ROAD
2018 INTERNATIONAL FUEL GAS CODE (IFGC
JURISDICTION:
BUILDING CODE AGENCY ......... City of WHEAT RIDGE
303.284.1276
FIRE DEPARTMENT ....................ARVADA FIRE PROTECTION DISTRICT
DEVELOPER
PLANING / ZONING ....................City of WHEAT RIDGE PLANING DEPARTMENT
JEFFERSON COUNTY
WATER ........................................City of WHEAT RIDGE (VALLEY WATER)
HOUSING AUTHORITY
SANITARY SEWER......................City of WHEAT RIDGE (CLEAR CKEEK VALLEY)
7490 W 45TH AVENUE
ELECTRIC ..................................... XCEL ENERGY
WHEAT RIDGE, CO 80033
NATURAL GAS............................. XCEL ENERGY
2018 IEBC CODE ANALYSIS
The majority of work on this project will fall under the 2018 IEBC and the definition for "Repairs" as defined in chapter 2.
The compliance path is as follows:
301.1.2: Work area compliance method: Repairs, alterations, additions, changes in occupancy and relocated buildings
complying with the applicable requirements of Chapters 5 –13 of this code shall be considered in compliance with this
code.
Notes: Majority of documented work in this building can be described as a replacement of interior finishes. There are
some instances of the building being upgraded for greater compliance with code for safety reasons. For example, railings
are being replaced with code compliant railings, but these instances are minimal.
The contractor has been instructed where possible to leave wall, ceiling, drywall assemblies in place in order to not
disturb the existing rated assemblies.
Therefore, we will be following the requirements based on the definition of alterations, and will fall under the requirements
of IEBC Chapter 7 Alternations – Level 1
Work will be in compliance with Section 701
Work will be in compliance with Section 702
702.4 – Materials and Methods
Notes: We dont anticipate any work to the building plumbing /mechanical systems outside of replacing fixtures and
appliances consistent with normal maintenance.
Work will be in compliance with Section 704 Fire Protection
Notes: The current level of fire protection will be maintained.
Work will be in compliance with Section 705 Accessibility
Notes: Due to a measurable amount of asbestos in the drywall texture, all alterations and repairs are being completed in
a manner that will not disturb the asbestos. All drywall will remain in place to the extent possible. Because of this,
accessibility improvements have been evaluated considering the entire site, and in order to minimize construction costs
alterations related to accessibility have been isolated to 2 of the 5 residential buildings on site, as well as the construction
of a new fully accessible community building with public facilities included. The 2 buildings with accessibility
improvements will have accessible entrances, and units complying with ICC ANSI A117.1 requirements for Type A
residential units.
For each building to be fully accessible compliant is technically infeasible as these buildings were constructed prior to any
accessibility requirements being in place.
Work will be in compliance with Section 706 Structural
Notes: We dont anticipate any structural work to the building.
Work will be in compliance with Section 707 Energy Conservation
Notes: The only alterations are the replacement of the entry windows and doors. These will comply with current IECC
requirements. New storefront at the building entry points will be a minimum if U 0.32.
3-802 BLDG 3 - ENLARGED CORRIDOR CEILING PLANS
3-803 BLDG 3 - INTERIOR CORRIDOR ELEVATIONS
3-804 BLDG 3 - UNIT INTERIOR ELEVATIONS
3-805 BLDG 3 - UNIT INTERIOR ELEVATIONS
3-806 BLDG 3 - UNIT INTERIOR ELEVATIONS
3-807 BLDG 3 - UNIT INTERIOR ELEVATIONS
UILDING 3 -STRUCTURAL
3-100 BUILDING 3 -GENERAL NOTES AND SECTIONS
3-101 BLDG 3 - FLOOR PLANS
3-101 D BLDG 3 - DEMO PLANS
UILDING 3 - PLUMBING
3-000 BUILDING 3 - PLUMBING SYMBOLS, NOTES, LEGENDS, SCHEDULES
3-100 BUILDING 3 - PLUMBING SITE NOTES
3-200 BUILDING 3 - TYPE A UNIT PLUMBING PLAN
UILDING 3 - ELECTRICAL
3-000 BUILDING 3 - ELECTRICAL SYMBOLS, NOTES, LEGENDS, SCHEDULES
3-100 BUILDING 3 - BASEMENT ELECTRICAL PLAN
3-101 BUILDING 3 - LEVEL 1 ELECTRICAL PLAN
3-102 BUILDING 3 - LEVEL 2 ELECTRICAL PLAN
3-200 BUILDING 3 - TYPE A UNIT ELECTRICAL PLANS
3-201 BUILDING 3 - ENLARGED ELECTRICAL UNIT PLANS
3-300 BUILDING 3 - COMMON AREA INTERIOR LIGHTING
3-301 BUILDING 3ACCESSIBLE UNITS:
BUILDING
ACCESSIBLE UNITS
EXISTING
PROPOSED
1
0
0
2
0
3
3
0
2
4
0
0
5
0
0
TOTAL: 5
F-
ASSOCIATED
DOCUMENTS:
CONSTRUCTION DOCUMENTS:
'CAESAR SQUARE - RENOVATION'
OVERALL SITEWORK RENOVATION PLAN SET
GEOTECHNICAL REPORT
Z
TERRACON GEOREPORT
PROJECT NO.: 25195383
2J
JANUARY 22, 2020
na/
PROJECT TEAM
ARCHITECT
CIVIL ENGINEER
ERIC BLASE
ROBERT PALMER
STUDIO 646 ARCHITECTURE, LLC
STRATEGIC LAND SOLUTIONS, INC.
15940 S. GOLDEN ROAD
2595 PONDEROSA ROAD
GOLDEN, CO 80401
FRANKTOWN, CO. 80116
303.284.1276
720.384.7661
DEVELOPER
SURVEYOR
JEFFERSON COUNTY
CHARLES BECKSTROM
HOUSING AUTHORITY
ENGINEERING SERVICE COMPANY
7490 W 45TH AVENUE
14190 E EVANS AVENUE
WHEAT RIDGE, CO 80033
AURORA, CO 80014
303.422.8600
303.337.1393
GENERAL CONTRACTOR
STRUCTURAL ENGINEER
TAYLOR KOH RS
CRAIG CARROLL
12160 PENNSYLVANIA ST.
MONROE & NEWELL ENGINEERS, INC.
THORNTON, CO. 80241
1400 GLENARM PL, SUITE 100
303.928.1800
DENVER, CO 80202
303.892.5980
303.623.4927
LANDSCAPE ARCHITECT
MEP
TOM KLEIN
BELFAY ENGINEERING
TICK DESIGN & PLANNING
2811 W 9TH AVE
2809 LARIMER ST.
DENVER, CO. 80204
DENVER, CO. 80205
303.892.5980
720.242.7947
0
a
F-
a
2
LU
Z
2J
na/
O0
J_
z�c(D
U
U
• �--�
o °
O
O
F
O
M
C)
O
T
OMM
'i
\"LU
J
LU
0
0
wED
W
W
(
vW
O
9
m
F -Z
z
LU
5
¢
0
w
tj
co
0
a
o
oM
N
'M
19-016
<1
DOM
NO.
0
0
0
0
�N
PLAN DATES
a
Z
na/
O0
J_
z�c(D
U
LU 0 N
• �--�
o °
W
O w o
M
C)
O
T
OMM
'i
\"LU
J
A3-001
Z
J_
m
OMM
'i
\"LU
J
0
LLI
�
DO
W
(
vW
O
C/5��/)
V J
Q
LU
W
>
0
LU<
co
C)
N
'M
19-016
SHEET
NO.
A3-001
ABBREVIATIONS ABBREVIATIONS ABBREVIATIONS GRAPHIC STANDARDS GENERAL UNIT ACCESSIBILITY NOTES GENERAL RENOVATION NOTES
1. The term Ownershall denote the client, or Owner, as designated in the Contract. The
# POUND(S) or NUMBER FHC FIRE HOSE CABINET PV. PAVEMENT , View Name DRAWING TITLE GENERAL: "Owner" g S
& AND FIN. FINISH(ED) PWD PLYWOOD 1/8" = 1'-0" SCALE 1. EXISTING DOOR ROUGH OPENINGS TO REMAIN FOR DOOR REPLACEMENT term "General Contractor" or "Contractor" shall denote the Corporation, Company,
< ANGLE FIXT FIXTURE U.N.O. RE: ACCESSIBLE UNIT NOTES (TYPE A) Partnership, Form or Individual who has entered into the Contract for the performance of
BUILDING SECTION 2. DOOR LOCKS AND DOOR HARDWARE SHALL BE LOCATED AT THE ENTRY the work and has engaged Subcontractors to perform a part of the work. The term
@ AT FL FLOORING) Q.T. QUARRIED TILE DOORS AT A HEIGHT NO HIGHER THAN 48" A.F.F. LEVER DOOR HARDWARE "Architect" refers to Studio 646 Architecture, LLC.". FLG FLASHING DIRECTION OF SIGHT A MEDICAL AIR FLUR FLUORESCENT R&S RESILIENT 1 IM DRAWING NUMBER REQUIRED AT EXTERIOR FACE OF DOOR. 2. The use of the words "provide" and "provided" in connection with any item specified shall 3. CHANGES IN LEVELWITHIN THE DWELLING UNIT THAT ARE BETWEEN 1/4" be intended to mean that the item shall be furnished, installed and connected where so
A/C AIR CONDITIONING FRP FIBERGLASS REINFORCED PANEL(ING) R. RISER A101 SHEET NUMBER AND 1/2" ARE TO BE BEVELED WITH A SLOPE NOT EXCEEDING 1:2. CHANGE INAB ANCHOR BOLT FT. FEET R.D. ROOF DRAIN LEVEL GREATER THAN 1/2" ARE TO BE RAMPED. THRESHOLDS AT EXTERIORrequired.
ABV ABOVE FTG FOOTING R. F. RESILIENT FLOORING WALL SECTION DOORS NOT TO EXCEED 1/2". EXTERIOR SLIDING DOOR TRACKS NOT TO 3. All dimensions are taken to face of stud, grid centerlines, or face of masonry unless
EXCEED 3/4" WHERE ACCESS TO EXTERIOR PATIO IS APPLICABLE
AC ACCOUSTICAL FURR FURRING R. L. RAIN LEADER DIRECTION OF SIGHT otherwise noted. Y
ACT ACCOUSTICAL CEILING TILE FUT FUTURE R. 0. ROUGH OPENING SIM
4. THE LANDING AT THE PRIMARY ENTRY DOOR IS TO BE NO MORE THAN 1/2" �
1 DRAWING NUMBER BELOW INTERIOR FINISH FLOOR. EXTERIOR LANDINGS MAY BE SLOPED AT 4. DO NOT scale drawings. Dimensions govern. Large scale details govern over small
ADD ADDENDUM R.O.D. ROOF OVERFLOW DRAIN A101 1/8" PER FOOT FOR DRAINAGE. g g g g _
SHEET NUMBER -. �.
ADJ ADJACENT orADJUSTABLE G.B. GRAB BAR R.W.C. RAIN WATER CONDUCTOR 5. EXTERIOR DECK, PATIO, OR BALCONY SURFACES ARE NOT TO BE 1/2" scale. oQ
AFF ABOVE FINISHED FLOOR GA. GAUGE RAD. RADIUS BELOW INTERIOR FINISH FLOOR UNLESS THEY ARE CONSTRUCTED OF Z
DETAIL CUT IMPERVIOUS MATERIAL SUCH AS CONCRETE, IN WHICH CASE, IT CAN BE 4" 5. Notify Architect immediately should conditions be found contradictory to these drawings. oz
AG AGGREGATE GALV GLAVANIZED RE. REFER TO or REFERENCE DIRECTION OF SIGHT BELOW THE FINISH FLOOR
AHU AIR HANDLING UNIT GCMU GLAZED CONCRETE MASONRY UNIT(S) REC RECESS(ED) SIM 6. The Drawings and Specifications are supplied to illustrate the design intent and the �o
AL ALUMINUM GD. GRADE REFR REFRIGERATOR or REFRIGERATED 1 DRAWING NUMBER 6. FRONT LOADING WASHER AND DRYER, DOOR TO LAUNDRY COMPARTMENT g type q y quality
15" MIN. -36" MAX ABOVE FLOOR general t e of construction required. The are intended to implythe finest of QI
ALT ALTERNATE GL. GLASS or GLAZING REINF REINFORCED A101 SHEET NUMBER construction, material and workmanship.
APSH ASPHALT GND GROUND REQ. REQUIRED BATHROOMS: 7. Drawings and general notes are complementary, and what is called for by one will be
APX APPROXIMATE(LY) GWB GYPSUM WALLBOARD REV REVISE, REVISED or REVISION SIM 1WALL DIMENSIONS AND FIXTURE LOCATIONS MUST BE HELD SO THAT THE binding as if called for by all. Work shown or referred to on any drawing shall be V I
ARCH ARCHITECTURAL GYP. GYPSUM RFG. ROOFING 1 . completed as though shown on all related drawings. '1
MINIMUM CLEARANCES ARE PROVIDED AS INDICATED ON THE PLAN. A
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS GYP. BD. GYPSUM BOARD RFL. REFLECTED A101 DETAIL CALLOUT CLEAR FLOOR SPACE OF 30"X48" SHALL BE PROVIDED WITHIN THE xx
AUTO AUTOMATIC RM. ROOM BATHROOM EXCLUSIVE OF THE DOOR SWING. 8. The character and scope of work are described by the drawings and notes contained >�
H.C. HOLLOW CORE 2. PROVIDE 2X WOOD BLOCKING IN LINE OF STUD FOR WALLS NOTED AS herein. Additional drawings and information deemed necessary by the Architect to Lu
B. 0. BY OWNER H.M. HOLLOW METAL S. SOUTH REQUIRING REINFORCING FOR FUTURE INSTALLATION OF GRAB BARS AS interpret and/or explain drawings, specifications or notes previously issued shall be
Ir
NOTED IN PLANS. FOR INFORMATION ON BLOCKING LOCATIONS. provided to the General Contractor. It shall be understood that such additional drawings
B.O.F. BY OWNER, FUTURE HDCP HANDICAP(PED) S.C. SOLID CORE ` J and information shall be considered part of the Contract Documents.
BD BOARD HDW HARDWARE S.C.D. SEAT COVER DISPENSER EXTERIOR ELEVATION 3. ALL TUB AND SHOWER SURROUNDS SHALL COME WITH INTEGRAL BLOCKING
FOR FUTURE INSTALLATION OF GRAB BARS. SEE DIAGRAM FOR REQUIRED g If there are any questions regarding the Contract Documents, existing conditions or
BEL BELOW HOR HORIZONTAL S. D. SOAP DISPENSER DIRECTION OF SIGHT GRAB BAR LOCATIONS.
BET BETWEEN HR HOUR S.N.C. SANITARY NAPKIN CABINET 1 DRAWING NUMBER 4. LAVATORIES ARE TO BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE design intent, the Contractor shall obtain a clarification from the Owners Representative
BIT BITUMINOUS HT HEIGHT S.N.D. SANITARY NAPKIN DISPENSER A MINIMUM OF 1'-3" HORIZONTALLY FROM AN ADJOINING WALL OR FIXTURE. or Architect prior to proceeding with the work in question. Lu
A10 SHEET NUMBER w
BKT BRACKET HVAC HEATING, VENTILATION and AIR S.N.R. SANITARY NAPKIN RECEPTACLEKITCHENS: 10. All work performed and material installed shall be, as a minimum standard, in strict Z p
BLDG BUILDING CONDITIONING S. R. SINK RECEPTACLE conformance with the latest editions of all general codes, regulations and ordinances O O
BLKG BLOCKING SCHED SCHEDULE INTERIOR ELEVATION including the building code. The Contractor shall give all notices and comply with all laws, a Lu
o
B.C. INTERNATIONAL BUILDING CODE or 1 1. PROVIDE A MINIMUM CLEAR DIMENSION OF 40" BETWEEN ANY WALL AND ordinances, rules, regulations and lawful orders of any public authority having jurisdiction
BLT BORROWED LIGHT SEC SECTION DIRECTION OF SIGHT BASE CABINET OR APPLIANCE O ¢
BM BEAM INSTALLED BY CONTRACTOR SF SQUARE FEET 4 2. CLEAR FLOOR SPACE OF 30" X 52" REQUIRED WITHIN KITCHEN TO ALLOW over the performance of the work. U o
A101 DRAWING NUMBER Lu a_
BOT, BOTTOM D. INSIDE DIAMETER SH. SHELF 2 PARALLEL APPROACH TO APPLIANCES AND FIXTURES.
.INCH SHEET NUMBER 3. WHERE NOTED ON UNIT PLANS: PROVIDE 30" WORKSPACE w/ REMOVABLE 11. Contractor is responsible for all work shown, noted, specified, or reasonably inferred from
BRG BEARNING SHR SHOWER 3CABINETRY; EXTEND FLOOR TO WALL; PAINT AND FINISH WALL the construction documents. N
BSMT BASEMENT NFO INFORMATION
0
SHT SHEET o
NS. NSULATION or INSULATED 4. COMBINATION REFRIGERATOR & FREEZER WITH 50 /o OF FREEZER 12. The General Contractor upon acceptance of the drawings and specifications assumes w
SHTG SHEATHING COMPARTMENT SHELVES SHALL BE 54" MAX ABOVE FLOOR
C.C.D. CONSTRUCTION CHANGE DIRECTIVE INT INTERIOR SIM SIMILAR - - 5. WHERE NOTED ON UNIT PLANS: SINK TO HAVE REMOVABLE CABINETRY; full responsibility for the construction, materials and workmanship of the work, and shall oNo
C.G. CORNER GUARD INTX INTERSECTION SPEC SPECIFICATION(S) 00.0 00.0 COLUMN CENTERLINE EXTEND FLOORING TO WALL, PAINT AND FINISH WALL, INSULATE PIPES FOR comply with the spirit as well as the letter of that which is contained therein.
REFERENCE GRID & BUBB E SINK PLAN DATES
C.J. CONTROL JOINT SQ. SQUARE 6. WHERE NOTED ON UNIT PLANS: RANGE TO HAVE CONTROLS AT THE FRONT 13. The scope si work described cr the Contract Documents implies i completed project. r 1
C.L.L. CONTRACT LIMIT LINE JAN. JANITOR SSK SERVICE SINK Minor omissions from and discrepancies in the drawings and specifications shall not void
JT. JOINT 00.0 OF THE UNIT such intention. The Contractor shall inform the Architect in writing of any conflicts, a
C.O. CHANGE ORDER SST STAINLESS STEEL
C.S.S. CLINICAL SERVICE SINK STA STATION TCLOSETS: omissions and discrepancies prior to construction.
C.T. CERAMIC TILE K. D. KNOCKDOWN STD STANDARD 1 14. The General Contractor shall obtain all required building permits. a
CAB. CABINET K.O. KNOCKOUT STL STEEL 1. WALK-IN CLOSETS: AT LEAST ONE CLOTHES ROD SHALL BE MOUNTED NOT W
00.0 HIGHER THAN 54" A.F.F. OR PROVIDE AN ADDITIONAL CLOSET ROD. O 00
CATV CABLE TELEVISION KIT KITCHEN STO STORAGE 15. The General Contractor shall obtain all special inspection required by the authority
KPL KICK PLATE Tv 2. CLOSETS LESS THAN 25" IN DEPTH: PROVIDE SPACE AND/OR BRACKETS FOR having jurisdiction over the project. z <
CCTV CLOSED CIRCUIT TELEVISION STIR STRUCTURE or STRUCTURAL 91 p 1
RE -LOCATION OF RODS HIGHER THAN 54" A.F.F.
CEM CEMENT SUSP SUSPEND(ED) O 0 O N
LAB LABORATORY 16. The General Contractor shall supervise and direct the work using his best skill and Q
CFL COUNTERFLASHING SYM SYMMETRICAL ELECTRICAL: r..4 00
v
LAM LAMINATE ROOM TAG 1. LIGHT SWITCHES, THERMOSTATS, AND OTHER ENVIRONMENTAL CONTROLS attention. He shall be solely responsible for all construction means, methods, techniques, • � U Q O
CK CAULKING) SYS SYSTEM sequences and procedures. He shall coordinate all portions of the work under theW O z 0
CL CENTERLINE LAV LAVATORY Room name -NAME MUST BE POSITIONED SUCH THAT CONTROL ARE LOCATED NOT HIGHER Contract. o Lu M
CLG CEILING LBL LABEL T&G TONGUE AND GROOVE NUMBER THAN 48" A.F.F. ELECTRICAL OUTLETS, PHONE AND CABLE T.V. JACKS MUST
BE MOUNTED SUCH THAT THE MINIMUM HEIGHT IS 15" A.F.F. SWITCHES, F-�---I rn 0
LKR LOCKER 17. General Contractor and subcontractors shall visit the project, as required by the h� Lb 0
CLO. CLOSET T. TREAD or TELEPHONE SQUARE FOOTAGE CONTROLS, AND/OR OUTLETS ABOVE KITCHEN OR BATHROOM
CLR CLEAR LLH LONG LEG HORIZONTAL T. B. TOWEL BAR COUNTERTOPS SHALL NOT EXCEED 44" A.F.F. specifications, to become familiar with all existing conditions affecting the proposed r 1
LLV LONG LEG VERTICAL demolition and new construction prior to submittal of bids. 4-1
CMU CONCRETE MASONRY UNIT T. 0. TOP OF J
CNTR COUNTER LT LIGHT T.P.D. TOILET PAPER DISPENSER r PARTITION OR WALL TYPE 18. The General Contractor shall perform high-quality professional work. Materials shall be
COL COLUMN LTL LINTEL TEL TELEPHONE 88a ACCESSIBLE UNIT NOTES (TYPE A) joined to uniform, accurate fits so that they meet in neat, straight lines free of smears or
LVR LOUVER RATED
CONC CONCRETE THK THICK or THICKNESS overlaps. Exposed materials shall be installed appropriately level, plumb and at accurate
ACOUSTIC right angles to or flush with adjacent materials. The work of each trade shall meet all pbotlq
CONN. CONNECTION THR THRESHOLD GENERAL: sP
National Standards published by the trade, except where the requirements of the Contact a° °tea �
M.O. MASONRY OPENING '°N
CONST CONSTRUCTION TPTN TOILET PARTITION NUMBER 1. MAXIMUM THRESHOLD HEIGHT SHALL NOT BE GREATER THAN 1/2" Document are more stringent.
MAS MASONRY
CONT CONTINUOUS TV TELEVISION 2. SHELVES IN LINEN OR PANTRY SHALL BE 9" MIN. AND 54" MAX. '
CONTR CONTRACT(OR) MAT MATERIAL TYP TYPICAL 19. The presence of an architectural representative on the jobsite does not imply
MAX MAXIMUM 3. DOORS INTO AND WITHIN APPLICABLE DWELLING UNITS SHALL PROVIDE FOR A
CORR CORRIDOR TZ TERRAZZO DOOR NUMBER CLEAR OPENING WIDTH OF 32" AND 34" MIN WIDE. CORRIDORS SHALL HAVE A concurrence cf approval of the work. The Contractor shall call to the attention of the
CPT CARPET MECH MECHANICAL 1t MINIMUM CLEAR WIDTH OF 36" AND MINIMUM CLEAR HEADROOM OF 80" Architect specific items for which he desires to obtain approval. Gi707ry9 D Co
MEP MECHANICAL, ELECTRICAL and PLUMBING
CTR CENTER U. L. UNDERWRITER'S LABORATORY WINDOW FRAME TYPE 20. The General Contractor shall correct defects in material and workmanship noted by the
CTSK COUNTERSINK MFR MANUFACTURER U.N.O. UNLESS NOTED OTHERWISE 1i GLAZING TYPE TAG Architect during periodic site observations and at project close-out.
MIN MINIMUM U.O.S. UNLESS OTHERWISE SPECIFIED BATHROOMS:
D. DRAIN or DATA MIR. MIRROR UNF. UNFINISHED O 21. The General Contractor shall turn the project over to the Owner free from all construction co
MISC MISCELLANEOUS 1. WATER CLOSET HEIGHT SHALL BE 15"MINIMUM TO 19" MAXIMUM MEASURED TO
D. F. DRINKING FOUNTAIN UR. URINAL TOP OF TOILET SEAT. debris, scraps, materials and equipment; with all interior glass free from manufacturer's
MMB MEMBRANE labels and tape and clean on both sides; with all doors built-in millwork wiped down and
D.S. DOWNSPOUT A3 TOILET ACCESSORY TAG 2. GRAB BARS SHALL BE 1-1/4" TO 1-1/2" IN DIAMETER WITH 1-1/2" BETWEEN WALL AND free of dirt, grease and other foreign material.
DBL DOUBLE V VACUUM z
MT. MOUNT(ED) GRAB BAR.
MTL METAL V.B. VAPOR BARRIER KEYNOTE DESIGNATION 3. GRAB BARS TO BE MOUNTED AT 33" MINIMUM TO 36" MAXIMUM AS SHOWN ON
DEPT DEPARTMENT PLANS U.N.O.
DET DETAIL MUL MULLION V.I.F. VERIFY IN FIELD OQ
4. GRAB BARS, WHEN INSTALLED, SHALL SUPPORT A WEIGHT OF 250 LBS AT ANY
DIA DIAMETER VCT VINYL COMPOSITION TILE REVISION DELTA POINT ALONG THE BAR. GENERAL DEMOLITION NOTES J
DIM DIMENSION (N) NEW VERT VERTICAL A� 5. TOILET PAPER DISPENSER TO BE MOUNTED 8" IN FRONT OF THE WATER CLOSET, _
DN DOWN N NORTH VEST VESTIBULE BETWEEN 15" AND 48" ABOVE THE FLOOR AND 1-1/2" ABOVE OR 12" BELOW A GRAB 1. CONTRACTOR SHALL VERIFY WITH OWNER ALL ITEMS IDENTIFIED TO BE SALVAGED
N.I.C. NOT IN CONTRACT BAR AND STORED FOR REUSE PRIOR TO COMMENCING WITH WORK.
DPR DISPENSER VIN VINYL Name VERTICAL ELEVATION 6. MEDICINE CABINET SHALL BE LOCATED WITH A USEABLE SHELF AT 44" MAXIMUM
DR DOOR N.T.S. NOT TO SCALE VTR VENT TO ROOF Elevation DATUM
NO. NUMBER A.F.F. 2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS SHOWN
DWG DRAWING VWC VINYL WALL COVERING 7. BOTTOM OF MIRROR SHALL BE 38" MAXIMUM A.F.F. ON DEMOLITION PLANS AND NOTIFY ARCHITECT IMMEDIATELY IF THERE ARE ANY
DWR DRAWER NOM. NOMINAL NORTH ARROW 8. A REMOVABLE IN -TUB SEAT SHALL BE PROVIDED. DISCREPANCIES.
W WEST N 9. PROVIDE SINGLE LEVER WATER CONTROL.
(E) EXISTING 02 OXYGEN W.C. WATER CLOSET 10. PROVIDE A SHOWER SPRAY UNIT WITH A 60" HOSE MINIMUM, THAT CAN BE USED AS 3. ALL ITEMS INDICATED AS DASHED ON DEMOLITION PLANS ARE TO BE REMOVED IN UJ
O.A. OVERALL A FIXED OR HAND HELD SHOWER. THEIR ENTIRETY. PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED FOR
E. EAST W.PT. WORKING POINT 11. PROVIDE MINIMUM CLEAR FLOOR SPACE FOR FIXTURES AS INDICATED IN PLANS.
0. C. ON CENTER INSTALLATION OF NEW FINISHES. M
E. D. EXHAUST DUCT W. R. WATER RESISTANT 12. PROVIDE MINIMUM CLEAR KNEE SPACE AS INDICATED IN INTERIOR ELEVATIONS. (7
E. H. EXHAUST FAN 0. D. OUTSIDE DIAMETER W.W.F. WELDED WIRE FABRIC GRAPHIC SCALE 13. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED TO PROTECT AGAINST 4. ALL SALVAGED AND STORED MATERIALS FOR RE -USE ARE THE GENERAL Q 0 LLI
E.J. EXPANSION JOINT 0. H. OPPOSITE HAND W/ WITH 0' CONTACT. SEE DRAWING FOR CLEARANCE DIMENSIONS. CONTRACTOR'S RESPONSIBILITY TO PROTECT, REINSTALL, AND CLEAN. 0 w
.. -
E.O.S. EDGE OF SLAB W/O WITHOUT
OT.OOUTSIDE-TO-OUTSIDE 14. FINISHED FLOORING SHALL EXTEND UNDER THE COUNTER TO THE WALL AT EACH DO
OFF. OFFICE LINE SYMBOLS CLEAR FLOOR SPACE. 5. WHERE EXISTING ELEMENTS ARE INDICATED TO REMAIN AND ARE LOCATED ON OR =
E.W.C. ELECTRIC WATER COOLER WB WASTE BASKET 15. GRAB BARS TO BE PRE-INSTALLED BY TUB & SHOWER SURROUND MFR @ ALL TYPE ADJACENT TO EXISTING CONSTRUCTION TO BE REMOVED, THESE ELEMENTS TOO C/).
OPGOPENING
EA. EACH WD WOOD A UNITS BE SALVAGED FOR RE -INSTALLATION AT NEW CONSTRUCTIONw
. U
EL. ELEVATION OPP. OPPOSITE WF. WIDE FLANGE 16. CONTRACTOR TO PROVIDE GRAB BARS FOR TOILETS AT ALL TYPE A UNITS. DO NOT � > ..
ELEC. ELECTRICAL WIN WINDOW CENTER LINE INSTALL. SEE DIAGRAM FOR REQUIREMENTS. 6. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR ADDITIONAL Q W LJJ
ELEV. ELEVATOR P.A.C. PREVIOUSLY AWARDED CONTRACT WP WATERPROOF(ING) 17. 34" TALL VANITY w/ REMOVABLE CABINETRY EXTEND FLOORING TO WALL, PAINT DEMOLITION THAT MAY NOT BE INDICATED ON ARCHITECTURAL DRAWINGS BUT IS I..L _ (� i
EM. EMERGENCY OUTLET P. L. PROPERTY LINE WSCT WAINSCOT AND FINISH WALL, INSULATE PIPES FOR SINK REQUIRED TO INSTALL DUCT WORK, PIPING, CONDUIT, ETC. PATCH AS REQUIRED. LC'L/ Q O
EMER. EMERGENCY P. R. PROPOSAL REQUEST GRID LINE KITCHENS: \ U
P.T. POST TENSIONED SLAB 7. NO EXISTING BUILDING ELEMENTS SHALL BE REMOVED IN WHOLE OR IN PART
ENGR. ENGINEER UNLESS OTHERWISE NOTED ON THE DRAWINGS. SHOULD IT BE NECESSARY TO r
P.T.D. PAPER TOWEL DISPENSER
EQ. EQUAL 1. ALL KITCHEN COUNTERTOPS SHALL BE 34" MAXIMUM. REMOVE AN ITEM NOT SCHEDULED FOR DEMOLITION IN ORDER TO COMPLETE THEUJ> Q M
2. PROVIDE MINIMUM CLEAR FLOOR SPACE FOR FIXTURES AND APPLIANCES AS
P. T. D. R. PAPER TOWEL DISPENSER AND RECEPTACLE
EQP EQUIPMENT WORK DESCRIBED HEREIN, THE GC SHALL NOTIFY THE ARCHITECT AND
EXP. EXPANSION P.T.R. PAPER TOWEL RECEPTACLE PROPERTY LINE INDICATED ON PLANS. STRUCTURAL ENGINEER PRIOR TO COMMENCING WITH WORK. EXISTING BUILDING Lid w
EXT EXTERIOR PFB. PREFABRICATED 3. THE DEPTH OF AT LEAST ONE BOWL AT THE KITCHEN SINK SHALL BE 6-1/2" ELEMENTS INCLUDE BUT ARE NOT LIMITED TO FLOORS, WALLS, CEILINGS, 0 = Q
PL. PLATE MAXIMUM. COLUMNS, AND BEAMS. 0'M
m
PLAM PLASTIC LAMINATE 4. FINISHED FLOORING SHALL EXTEND UNDER THE COUNTER TO THE WALL AT EACH
F.B.O. FURNITURE BY OWNER CUT LINE 5. CLEAR FLOOR SPACE. 8. SHADED AREAS ON THE RELECTED CEILING PLAN INDICATE AREA WHERE EXISTING
F. D. FLOOR DRAIN PLAS PLASTER 6. PROVIDE LEVER HARDWARE AT KITCHEN FAUCET. CEILING GRID IS TO BE REMOVED AND REPLACED.
F. E. FIRE EXTINGUISHER PNL PANEL 7. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED TO PROTECT AGAINST 19-016
F. R. FIRE RESISTIVE PNTD PAINTED CONTACT. 9. ALL INCIDENTAL ITEMS NOT CONSISTENT WITH NEW WORK SHALL BE REMOVED
PLAN MATCH LINE 8. A DISHWASHER SHALL BE PROVIDED TO ACCOMMODATE 34" COUNTER IN THE 2- FROM WALLS AND CEILINGS RECEIVING NEW FINISH. SEE DEMOLITION PLANS FOR
F.R.T. FIRE RETARDANT TREATED PR. PAIR BDRM UNIT SPECIFIC INFORMATION. SHEET NO.
FACP FIRE ALARM CONTROL PANEL PROJ PROJECT 9. CONTROLS FOR THE RANGE SHALL NOT REQUIRE REACHING ACROSS BURNERS.
FAS. FASTEN(ER) PSF POUNDS PER SQUARE FOOT 10. BOTTOM OF WALL CABINETS SHALL NOT EXCEED 48" A.F.F. 10. ALL EXISTING CONCRETE SLAB TO BE REMOVED SHALL BE SAW CUT.
FDN FOUNDATION PSI POUNDS PER SQUARE INCH A3-002
FEC FIRE EXTINGUISHER CABINET PT. PAINT or PAPER TOWEL CLOSETS: 11. REFERENCE ARCHITECTURAL DRAWINGS FOR ADDITITIONAL DEMOLITION
FFL FINISHED FLOOR LINE PTN. PARTITION 1CLOSET SHELVING SHALL BE MOUNTED AT A MAXIMUM OF 54" A.F.F. INFORMATION ON EXISTING BUILDING NOT INDICATED ON DEMOLITION DRAWINGS.
.
2 MINIMUM 20" DOOR AT ALL CLOSETS 24" DEEP OR SHALLOWER. 12. VERIFY IN FIELD: DRAINS OPERATING AND NOT CLOGGED BY DEBRIS, ETC.
a
N
(`�
O
N
O
N
r
N
V
I r_ tel- n 11 i
A3-401
EXISTING LEVEL 2 FLOOR PLAN u
1/811 = 1'-0"
A3-401
I
EXISTING LEVEL 1 FLOOR PLAN
1/811 = 1'-0"
!Y
!Y
<2 3-401
hK Cp�o
ERIC C o
L
U)
0
C)
0
LU
Q
0
a
N
O
N
74
PLAN DATES
/ Pbbott Asso
6�9� caeN\
/
O
C
\an9 DN`s•
a
a
�
,Q0
J
W
(�-
o0
Q
Z 0 �o
OJ
M
oo
O
O
L N
00
LL
[��y
V
w
" w0
z
OM
0
C /wT
�I J
/LLJ
(D
V
X
/ Pbbott Asso
6�9� caeN\
/
O
C
\an9 DN`s•
19-016
69:Igamr►C•a
A3-101
C/)
�
J
W
Q
M
oo
O
O
00
LL
[��y
V
LU
O
z
>Q
1:
/LLJ
(D
V
X
Q
00
Lu
W
�Q
M
Q
rn=
LLJ
0
19-016
69:Igamr►C•a
A3-101
a
0
N
N
(`�
O
N
O
N
r
N
V
ROOF DEMOLITION PLAN
1/16" = T-0"
UNIT 116
IIIT7 � R
1111 1
UNIT 115
CORRIDORS:
FLOORING:
REMOVE CARPET & PADDING.
ELECTRICAL:
REMOVE EXISTING LIGHT FIXTURES
STAIRS:
REMOVE CARPET & PADDING,
O
REMOVE HANDRAILS
DOORS:
REMOVE EXISTING UNIT ENTRY DOORS
I
REMOVE EXISTING EXTERIOR BUILDING
W
ENTRY DOORS
UNITS:
REFER TO ENLARGED UNIT DEMOLITION PLANS
UNIT 119 UNIT 120
UNIT 117 UNIT 11188 F9 — ==...� L
UNIT 114 UNIT 113 UNIT 112
T
"UNIT 111
T 1� r 7T I 7Ft
LEVEL 2 DEMOLITION FLOOR PLAN
1/16" = T-0"
1ri1»_A
ALL DRYWALL TO BE REMOVED
THROUGHOUT ENTIRE UNIT. REFER TO
ENLARGED UNIT DEMOLITION PLANS FOR
FURTHER DETAILS AND INFORMATION.
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR WALL
LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF RECORD IN ORDER TO
DETERMINE IF IT IS PART OFA FIRE RATED SYSTEM. IF IT IS DETERMINED TO BE
PART OFA FIRE RATED SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN
APPROPRIATE REPAIR.
FLOORING:
REMOVE CARPET & PADDING.
ELECTRICAL:
REMOVE EXISTING LIGHT FIXTURES
STAIRS:
REMOVE CARPET & PADDING,
O
REMOVE HANDRAILS
DOORS:
REMOVE EXISTING UNIT ENTRY DOORS
I
REMOVE EXISTING EXTERIOR BUILDING
W
ENTRY DOORS
REFER TO ENLARGED UNIT DEMOLITION PLANS
UNIT 106 UNIT 107 UNIT 108` UNIT 109
.� �
ILL
'r O�-
C as �
UNIT 105UNIT 104 UNIT 103 UNIT 102
L L
LEVEL 1 FLOOR DEMOLITION PLAN
Iriill-BIQe➢
:7g9q iEelq►1/_VZelgo1l1►11297:1LA[e]III[07►INI_U61
FLOORING:
REMOVE CARPET & PADDING.
ELECTRICAL:
REMOVE EXISTING LIGHT FIXTURES
STAIRS:
REMOVE CARPET & PADDING,
O
REMOVE HANDRAILS
DOORS:
REMOVE EXISTING UNIT ENTRY DOORS
I
REMOVE EXISTING EXTERIOR BUILDING
W
ENTRY DOORS
BASEMENT DEMOLITION FLOOR PLAN
1/16" = T-0"
UNIT 110
UNIT 101 J��
' TT
w�
F
UNIT B1
00
UNIT B2
� o
a
E
hK Cp�o
ERIC C o
F --
Lu
U)
n
O
0
Lu
a
N
O
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
0
c
\an9 DN`s•
��
V
Z
a
O
U
J
O
Q
O
a
M�
W
`Q0(
I
O
W
-
00
M O
W
zcl�c(o
0 Lu
Do 0
W 0 N
�
W
(D w M
V M
O
°) o
T
N.
J
/ pbotl Asso
6�9� caeN\
0
c
\an9 DN`s•
��
V
Z
Q
ry
O
U
J
O
Q
O
0�
M�
W
LL
z
I
O
W
J
M O
W
�Q
0 Lu
Do 0
19-016
69:Igilr►C.l
A3-103
Lu
O
U
J
Q
LLJ
0�
QDo
(D
Lu
>
W
�Q
co
�
N
19-016
69:Igilr►C.l
A3-103
a
N
N
N
(`�
O
N
O
N
r
N
V
(N) WALL (TYPI)�
A2
PROPOSED LEVEL 2 FLOOR PLAN u
J 1/8" = T-0"
(N) CONC. RAMP TO I
FOLLOW ADA STANDARDS=_
(E) CONC. STOOP &
BRICK HANDRAIL WALLS
TO BE DEMOLISHED &
REBUILT NO LESS THAN _
1/2" BELOW FINISH FLOOR i
1
3-604
(N) MTL. GUARD RAIL (TYP.) I- PATIO I
3 / Aic
ATI(CON( STOOP A 2 (N) WINDOW WELL COVERS TO BE PROVIDED
ATIO (TYP.) � AT ALL WINDOW WELLS DEEPER THAN 30"
PATIO \s/ PATIO PATIO AND WHERE A SIDEWALK IS WITHIN 36" OF
MTL. HAND RAIL (TYP.) - - - - - THE EDGE OF THE WINDOW WELL.
JI, I III
EXTERIOR LIGHT FIXTURE
LL LEVEL 1 PATIOS (TYP.)�`A/C A/C A/C '-T 7 \ fT 7 j --T -T
// t A/C i
!Y
!Y
4'-0"
41- 0111
101
UNIT 103
UNIT 105
UNIT 107
Z
UNIT 109
0
J_
o
J
I
UNIT TYPE: 3-2.4
UNIT TYPE: 3-2.1
UNIT TYPE: 3-2.1
W
UNIT TYPE: 3-1.1
o
UNIT TYPE: 3-2.5
M
O
Q
3
/TYPE A/Z
° O RE: 3 /A3-303
° 0
RE: 3 /A3-303 O o
0 0Ll
RE: 3 /A3-301
0
(�
w
RE: 3 /A3-308
PATIO
��v//��
U) J
Q
RE: 2 /A3-307
LLI
O
a
O
Q
~
c
0
Q�
a
W<
co
Q
LO
0)
Lu
-r
0
C.)
19-016
SHEET
NO.
00 2 o O
, 5' _ 0^ I ��LINE OF CORRIDOR *--(N) COMMERCIAL CPT. TILES
UP FLR. ABOVE �� 3-60
00
° O DN
o °
I
,UNIT 102/ Eo UNIT 104 UNIT 106 UNIT 108 UNIT 110
C UNIT TYPE: 3-2.4 UNIT TYPE: 3-2.1 UNIT TYPE: 3-2.1 0 0 UNIT TYPE: 3-2.1F700-00F]UNIT TYPE: 3-2.5 PATIO
�ET2 E 307 RE: 3 /A3-303 RE: 3 /A3-303 RE: 3 /A3-303
a o v RE: 3 /A3-308
0 A/C % A/C
PATIO I A/C A/C A/C
(N) MTL. GUARD RAIL (TYP.) — — _ _ = PATIO
TIO
3-604 PATIO PATIO
PATIO A3-402
Cz
PROPOSED LEVEL 1 FLOOR PLAN
1/8" = 1'-0"
<2 3-402
<2 3-402
m
z Z
w w
Lu
O U OF ��
a Lu aco wco
LU co m
0uio cD�U�
W a 00
D comN co m
N N
O N O
N O N
W � N
H " N
O O
PLAN DATES
a
a
00
z0�
oJ W OJ N
U O0co
w " w0
OM
O
C /wT
�I J
es Abbott Asso
6�9� caeN\
e��7aipa D``1`�`oc
c' J
Z
J_
J
I
�
W
o
M
O
Q
O
U-
co
0
(�
w
O
LU
��v//��
U) J
Q
O
LLI
O
a
O
Q
~
c
0
Q�
a
W<
co
Q
LO
0)
Lu
-r
0
C.)
19-016
SHEET
NO.
A3-105
a
M
N
N
(`�
O
N
O
N
r
N
V
CPT. FL
SHT. VI
FLOOR
UNIT 3-1.1 - EXISTING FLOOR PLAN
1/4" = 1'-0"
LIVING ROOM BEDROOM
SD
CLO
SD
LIN
BATH
KITCHEN &
DINING
O T
FLOOR/CEILING ASSEMBLY TO
FOLLOW RATING AND DETAILS
ON SHEET A3-605
UNIT 3-1.1 - REFLECTED CEILING PLAN
1/4" = 1'-0"
REMOVE AT UN -SHADED AR
-CARPET FLOORING
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
REMOVE AT SHADED AREA:
-CABINETS
-COUNTERTOPS
-APPLIANCES
-SHEET VINYL FLOORING
-PLUMBING FIXTURES
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
-TUB AND SHOWER SURROL
-DASHED ITEMS
OVE DRYWALL @
LS IN BATHROOM
O WALL
=MBLY AT
BROOM AT
RIDOR WALLS.
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
UNIT 3-1.1 - DEMO FLOOR PLAN REPAIR.
1/4" = T-0"
E407
E435
E434_
E401_
E401
E436
UNIT 3-1.1 - PROPOSED FINISH PLAN
1/4" = 1'-0"
.]aIIIG1IwKelQG9:ImIa/GBE1-161
424
❑ UNIT 3-1.1 (LEVEL 1 ONLY)
KEY PLAN
WALL TYPES LEGEND
EXISTING PARTITION TO REMAIN
®DN6911►[H�G1:�111[•]►�CH:3�:7q� [�DIq�]
NEW PARTITION
ELECTRICAL SYMBOLS
EXHAUST FAN
SMOKE/ CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
GENERAL UNIT PLAN NOTES:
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
422
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
NEW VANITY LIGHT FIXTURE
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
437
ADD EXTERIOR LIGHT FIXTURE AT GROUND FLOOR PATIO
WHERE NOTED ON OVERALL PLANS.
hK Cp�o
ERIC C o
Lu
U)
0
0
0
Lu
a
N
0
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
a
Q
a
J_
z
W
na/
O0
z 0 �D
OJ
o
W N
r
M
0.
co
L:
Ow o
\,/
~
V M
O
O) o
11 ,,
T
M
VJ
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
Q
a
J_
z
W
a
WL
r
M
0.
co
L:
M
o
M
0
W
U)
;O �
Q
Lu (D
J
Q
�
co
0
Z
W
W
�a
co
�2
0
19-016
69:Igilr►C•a
A3-301
UNIT 3-1.2 - EXISTING FLOOR PLAN
1/4" = 1'-0"
FLOOR/CEILING ASSEMBLY TO -
FOLLOW RATING AND DETAILS
ON SHEET A3-605
UNIT 3-1.2 - REFLECTED CEILING PLAN
1/4" = T-0"
REMOVE AT UN-SHAC
-CARPET FLOORING
-ELECTRICAL SWITCH
-ELECTRICAL OUTLET
-ELECTRICAL FIXTURE
REMOVE AT SHADED
-CABINETS
-COUNTERTOPS
-APPLIANCES
-SHEET VINYL FLOORI
-PLUMBING FIXTURES
-ELECTRICAL SWITCH
-ELECTRICAL OUTLET
-ELECTRICAL FIXTURE
-TUB AND SHOWER SI
-DASHED ITEMS
UNIT 3-1.2 - DEMO FLOOR PLAN
1/4" = 1'-0"
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
UNIT 3-1.2 - PROPOSED FINISH PLAN
1/4" = 1'-0"
.]aIIF-AIwY•]►G9:IgarGvi11.1 7
WALL @
HROOM
ASSEMBLY
M AT
ALLS.
❑ UNIT 3-1.2 (LEVEL 2 ONLY)
KEY PLAN
WALL TYPES LEGEND I
EXISTING PARTITION TO REMAIN
®DN6911Q[el�G1:�111[�]Q�CU:3�:7q� �[�DI q�]
NEW PARTITION
ELECTRICAL SYMBOLS
O EXHAUST FAN
SMOKE / CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
GENERAL UNIT PLAN NOTES: I
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
402
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
410
REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS.
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
422
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
NEW VANITY LIGHT FIXTURE
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
hK Cp�o
ERIC C o
Lu
U)
0
0
0
Lu
a
N
0
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
V
Z
a
Z
J
Z
Q
W
r
n_/
O0
Z 0 (D
o
Lu W 0 N
M
co
W
O w o
F-�---I
M
O
v O
T
M
VJ
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
V
Z
Z
J
Z
Q
W
r
W
�
N
WI
M
co
L:
Q
o
M
D
W
U)
;O �
Q
Lu (D
J
Q
Dp
p
Z
W
Lu
Q
co
�2
D
U
(3
19-016
69:Igilr►E.]
A3-302
SHT. VIN
FLOORI(
CPT. FLOORIP
UNIT 3-2.1 - EXISTING FLOOR PLAN
1/4" = 1'-0"
FLOOR/CEILING ASSEMBLY TO
FOLLOW RATING AND DETAILS
ON SHEET A3-605 LIGHT PUFF PER SPECS
'..
O
BATH
D
LIN
CLO
O
SD
BEDROOM1
Op LIVING ROOM
CLO
BEDROOM1
O
SD
UNIT 3-2.1 - REFLECTED CEILING PLAN
00
O
O
SD
LIVING ROOM
DEMO WALL ASSEMBL"
AT BATHROOM AT
CORRIDOR WALLS.
REMOVE DRYWALL @
WALLS IN BATHROOM
WALL F
FOLLO
DETAIL
UNIT 3-2.1 - DEMO FLOOR PLAN
1/4" = 1'-0"
REMOVE AT SHADED AREA:
-CABINETS
-COUNTERTOPS
-APPLIANCES
-SHEET VINYL FLOORING
-PLUMBING FIXTURES
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
-TUB AND SHOWER SURROUND
-DASHED ITEMS
REMOVE AT UN -SHADED AREA:
-CARPET FLOORING
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
UNIT 3-2.1 - FINISH PLAN
1/4" = 1'-0"
UNIT 3-2.1 (LEVEL 1 ONLY)
KEY PLAN
WALL TYPES LEGEND
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
EXHAUST FAN
SMOKE/ CARBON MONOXIDE DETECTOR
SURFACE MOUNTED LIGHT FIXTURE
EMMA10L A[oil]QllgelI[c3:129K411117q
UIgIII►Eel yGUI
GENERAL UNIT PLAN NOTES:
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
402
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
412
ADD HEADER AT ALL CLOSET DOORS. HEAD HEIGHT @ 6-8".
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
YL
G-
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
a
REPLACE ALL PLUMBING SHUT-OFF VALVES @ KITCHEN
SINK, BATH SINK, TOILET W/ NEW 1/4 TURN VALVES.
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
434
REPLACE ALL LIGHT FIXTURES
435
C O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
603
CORRIDOR WALLS TO BE REPAINTED WITH ACCENT COLOR,
PT -7. RE: INTERIOR PAINT SCHEDULE. (TYP.)
Q
Dp
p
Z
W
C^
W
144-
�a
L
co
Lo
LLJ2
D
Uco')�m
o O
O
IG—
GBEDROOM1
_CLO.
CLO.
BEDROOM1BEDROOM 2 LIVING ROOM
UNIT 3-2.1 - EXISTING FLOOR PLAN
1/4" = 1'-0"
FLOOR/CEILING ASSEMBLY TO
FOLLOW RATING AND DETAILS
ON SHEET A3-605 LIGHT PUFF PER SPECS
'..
O
BATH
D
LIN
CLO
O
SD
BEDROOM1
Op LIVING ROOM
CLO
BEDROOM1
O
SD
UNIT 3-2.1 - REFLECTED CEILING PLAN
00
O
O
SD
LIVING ROOM
DEMO WALL ASSEMBL"
AT BATHROOM AT
CORRIDOR WALLS.
REMOVE DRYWALL @
WALLS IN BATHROOM
WALL F
FOLLO
DETAIL
UNIT 3-2.1 - DEMO FLOOR PLAN
1/4" = 1'-0"
REMOVE AT SHADED AREA:
-CABINETS
-COUNTERTOPS
-APPLIANCES
-SHEET VINYL FLOORING
-PLUMBING FIXTURES
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
-TUB AND SHOWER SURROUND
-DASHED ITEMS
REMOVE AT UN -SHADED AREA:
-CARPET FLOORING
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
UNIT 3-2.1 - FINISH PLAN
1/4" = 1'-0"
UNIT 3-2.1 (LEVEL 1 ONLY)
KEY PLAN
WALL TYPES LEGEND
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
EXHAUST FAN
SMOKE/ CARBON MONOXIDE DETECTOR
SURFACE MOUNTED LIGHT FIXTURE
EMMA10L A[oil]QllgelI[c3:129K411117q
UIgIII►Eel yGUI
GENERAL UNIT PLAN NOTES:
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
402
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
412
ADD HEADER AT ALL CLOSET DOORS. HEAD HEIGHT @ 6-8".
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
430
REPLACE ALL PLUMBING SHUT-OFF VALVES @ KITCHEN
SINK, BATH SINK, TOILET W/ NEW 1/4 TURN VALVES.
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
603
CORRIDOR WALLS TO BE REPAINTED WITH ACCENT COLOR,
PT -7. RE: INTERIOR PAINT SCHEDULE. (TYP.)
h�pF Cp�o
ERIC C o
Lu
Lu
0
0
0
Lu
0
a
N
0
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
V
Z
a
Q
a
J_
z
W
r
W
O o
zcl�c(o
�
W
W 0 N
N
M
co
WO
w
o
F—�---I
OM
0
v O
Lo 0
M
VJ
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
V
Z
Q
a
J_
z
W
r
W
�
W
N
M
co
~
o
M
D
W
U)
;O �
Q
Lu (�
J
Q
Dp
p
Z
W
C^
W
144-
�a
L
co
Lo
LLJ2
D
Uco')�m
19-016
69:Iq011r►[•a
A3-303
L
CPT.
UNIT 3-2.2 - EXISTING FLOOR PLAN
1/4" = 1'-0"
FLOOR/CEILING ASSEMBLY TO
FOLLOW RATING AND DETAILS
ON SHEET A3-605 LIGHT PUFF PER SPECS
UNIT 3-2.2 - REFLECTED CEILING PLAN
1/411 = 1'-0"
DEMO WALL ASSEMB' 11
AT BATHROOM AT
CORRIDOR WALLS.
REMOVE DRYWALL Ca
WALLS IN BATHROOM
UNIT 3-2.2 - DEMO FLOOR PLAN
1/4" = 1'-0"
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
UNIT 3-2.2 - FINISH PLAN
1/4" = 1'-0"
AT SHADED AREA:
-S
RTOPS
ICES
IINYL FLOORING
JG FIXTURES
ICAL SWITCHES
ICAL OUTLETS
ICAL FIXTURES
)SHOWER SURROUND
ITEMS
AT UN -SHADED AREA:
FLOORING
ICAL SWITCHES
ICAL OUTLETS
ICAL FIXTURES
❑ UNIT 3-2.2 (LEVEL 2 ONLY)
KEY PLAN
WALL TYPES LEGEND I
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
D EXHAUST FAN
SMOKE / CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
I GENERAL UNIT PLAN NOTES: I
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
412
ADD HEADER AT ALL CLOSET DOORS. HEAD HEIGHT @ 6-8".
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
417
NEW BLACKTOP -FREEZER REFRIDGERATOR
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
hK Cp�o
ERIC C o
Lu
U)
0
0
0
Lu
a
N
0
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
a
Q
a
J_
z
W
r
na/
O0
z�c(D
WL
W 0 N
N
M
0.
co
L:
Ow o
--
0 M
v O
T
M
VJ
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
Q
a
J_
z
W
r
W
N
WL
N
M
0.
co
L:
M
o
M
D
W
U)
;O E
Q
Lu (D
J
Q
H
Dp
p
Z
W
Lu
a
co
Qrn
=
(D
0
U��m
19-016
69:Igamr►C•a
A3-304
UNIT 3-2.3 - EXISTING FLOOR PLAN
1/4" = 1'-0"
UNIT 3-2.3 - REFLECTED CEILING PLAN
irzl I ISl➢
J
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
III
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
404
A/C
BEDROOM 1
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
LIVING ROOM
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
UNIT 3-2.3 - DEMO FLOOR PLAN
1/4" = 1'-0"
DRYWALL @
JBATHROOM
AT UN -SHADED AREA:
FLOORING
ICAL SWITCHES
ICAL OUTLETS
ICAL FIXTURES
AT SHADED AREA:
FS
=RTOPS
ICES
IINYL FLOORING
JG FIXTURES
ICAL SWITCHES
ICAL OUTLETS
ICAL FIXTURES
D SHOWER SURROUND
ITEMS
UNIT 3-2.3 - PROPOSED FINISH PLAN
❑ UNIT 3-2.3 (LEVEL 2 ONLY)
KEY PLAN
WALL TYPES LEGEND I
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
0 EXHAUST FAN
SMOKE / CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
I GENERAL UNIT PLAN NOTES: I
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
422
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
428
REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING
TUB WHERE REQ'D.
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
NEW VANITY LIGHT FIXTURE
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
hK Cp�o
ERIC C o
Lu
U)
0
0
0
Lu
a
N
0
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
a
Q
a
J_
z
W
r
na/
O0
z 0 (D
OJ
o
Lu N
W
N
M
0.
co
L:
Ow o
--
0 M
v O
T
M
VJ
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
Q
a
J_
z
W
r
CIOW
�
WI
N
M
0.
co
L:
M
o
M
D
W
U)
;O �
Q
Lu (D
J
Q
H
Dp
p
Z
W
ui
Q
co
LJJ
2
(D�
D
Um�m
19-016
69:Igilr►Ce]
A3-305
a
0
M
M
0
N
O
N
r
N
V
a
68 1/2"
FUR 2x6 WALL OUT AT
EXTERIOR FOR ADDITIONAL
PLUMBING & INSULATION
REFER TO ROLL -IN
SHOWER DETAILS
ON SHEET A3-606
VANITY WITH REMOVABLE
CABINET & PIPE PROTECTION
AT SINK. PAINT WALL BEHIND
CABINET & EXTEND FLOORING
BENEATH CABINET.
NEW FLOORING MATERIAL TO
BE SMALL -FORMAT TILE, SPEC,
TBD BY ARCHITECT. SLOPE
TILE TOWARDS FLOOR DRAIN &
SHOWER THRESHOLD.
ADD BLOCKING FOR GRAB
BARS THESE LOCATIONS.
REFER TO DETAILS ON SHEET
A3-606.
UNIT 3-2.4 TYPE A - ENLARGED BATHROOM
1/211 = 1'-0"
BEDROOM 1
CLO.
Sp
BEDROOM 2
GENERAL UNIT PLAN NOTES:
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT 3-2.4 TYPE A - FINISH PLAN
1/411 = 1'-0"
7' - 8" 1 12'- 1 3/4"
5 I (N) BLOCKING TO BE
3-307 I INSTALLED
D
LIVING ROOM BEDROOM 1 i f<6
,BATHLIVING ROOM
FLOOR/CEILING ASSEMBLY TO 3-80 4>
11 BATH FOLLOW RATING AND DETAILS (E) RADIANT BASE BOARD
a ON SHEET A3-605 HEATING ELEMENT TO BE
RELOCATED TO NEW WALL
22 21 (N) BLOCKING TO BE
INSTALLED
N CLO.
SD J
ALIGN WALLS 22 KITCHEN &
z 1 CLO. DINING
CLO. ALIGN WALLS A3-80 2> -
� I of
KITCHEN &
DININGV r r��
V BEDROOM 2 \I
i
18" � _
MIN. L L O L
o
$
o
NEW WALLS TO FOLLOW RATING
AND DETAILS FOR CORRIDOR WALL 7 1/2"
ASSEMBLY. RE: A3-605
12" MIN.
UNIT 3-2.4 - TYPE A - REFLECTED CEILING PLAN
1/4" = 1'-0"
UNIT 3-2.4 TYPE A - PROPOSED FLOOR PLAN
1/4" = 1'-0"
11m
❑ UNIT 3-2.4 TYPE A (LEVEL 1 ONLY)
KEY PLAN
WALL TYPES LEGEND
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
O EXHAUST FAN
SMOKE / CARBON MONOXIDE DETECTOR
SID
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
410
REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS.
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
422
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
NEW GARBAGE DISPOSAL
428
REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING
TUB WHERE REQ'D.
431
NEW CHROME BATH ACCESSORIES
433
NEW VANITY LIGHT FIXTURE
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
439
SIDE-BY-SIDE REFRIDGERATOR/FREEZER W/ WATER & ICE
DISPENSER @ ALL TYPE 'A' UNITS.
440
30" MIN. CLEAR WORKSPACE REQ'D IN TYPE W UNITS.
PROVIDE REMOVABLE CABINET FACE & EXTEND FINISH
FLOOR TO FACE OF WALL. PAINT WALL BEHIND CABINET.
441
PROVIDE REMOVABLE CABINET FACE @ SINK CABINET &
EXTEND FINISH FLOOR TO FACE OF WALL BEYOND. PAINT
WALL BEHIND.
443
MICROWAVE TO BE MOUNTED UNDER 34" COUNTER TOP @
ALL TYPE 'A' UNITS.
444
ADA COMPLIANT DISHWASHER TO FIT UNDER 34" COUNTER
AT ALL TYPE 'A' UNITS.
446
RECESS GARBAGE DISPOSAL AIR SWITCH INTO
COUNTERTOP WITHIN ADA REACH RANGES @ ALL TYPE 'A'
UNITS.
449
PROVIDE REINFORCEMENT FOR WALL MOUNTED GRAB
BARS.
W=
w
2
Lu 2J
U O F
0 a2
Lu Lu
�5
¢ j co
00
mm
0 0
N
PLAN DATES
a
a
00
z12�c(o
W 0 N
• r� U
o
O
o O o
W O w
O o
M
— x LoO � cD
s pbotl gsso
a
v�9� ca�w�
0
eG�� 2\c
a�p9 p� J
c n) (D
V C/)
Z =
a
J_ Q
W
a
� N
W
M
0. co M L:
o
M D
W
U) ;
UNIT 3-2.5 - EXISTING FLOOR PLAN
1/4" = 1'-0"
0
KITCHEN &
DINING
7:S
FLOOR/CEILING ASSEMBLY TO
FOLLOW RATING AND DETAILS
ON SHEET A3-605
LIVING ROOM
CLO B ROOM 1
O�
CLO
❑
BATH
0
O"
CLO
�;oou
UNIT 3-2.5 - REFLECTED CEILING PLAN
1/411 = 1'-0"
REMOVE AT SHADED
-CABINETS
-COUNTERTOPS
-APPLIANCES
-SHEET VINYL FLOOR
-PLUMBING FIXTURES
-ELECTRICAL SWITCH
-ELECTRICAL OUTLET
-ELECTRICAL FIXTURE
-TUB AND SHOWER SI
-DASHED ITEMS
REMOVE AT UN-SHAE
-CARPET FLOORING
-ELECTRICAL SWITCH
-ELECTRICAL OUTLET
-ELECTRICAL FIXTURE
REMOVE DRYWALL Ca
WALLS IN BATHROOM
UNIT 3-2.5 - DEMO FLOOR PLAN
1/4" = 1'-0"
FILING OR
ITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OFA FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
UNIT 3-2.5 - PROPOSED FINISH PLAN
1/4" = 1'-0"
❑ UNIT 3-2.5
KEY PLAN
WALL TYPES LEGEND I
DyN6911►[el�G1:�111[•]►�C•7:7q� G11Q
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
O EXHAUST FAN
SMOKE / CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
I GENERAL UNIT PLAN NOTES: I
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
402
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
404
REPAINT ALL WINDOW SILLS
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
422
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
424
NEW PORCELAIN TOILET, WHITE
428
REPLACE ALL WALL TILE IN SHOWER. REFINISH EXISTING
TUB WHERE REQ'D.
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
NEW VANITY LIGHT FIXTURE
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
436
REPLACE ALL CEILING FANS IN BEDROOMS
hK Cp�o
ERIC C o
Lu
U)
0
0
0
Lu
a
N
0
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
a
Q
a
J_
z
C7
r
n_/
O0
z�c(D
WL
W 0 N
N
M
0.
co
W
O w o
F-�---I
M
O
v O
T
M
0
LLJ
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
cy)
(D
Z
Q
a
J_
z
C7
r
LoW
WL
N
M
0.
co
L:
o
M
0
LLJ
O
W
(D
U)
'
Q
Lu (D
J
Q
Dp
0
Z
W
Lu
a
co
�
LLJ
2
0
Urn�m
19-016
69:Igamr►C•a
A3-308
UNIT 3-2.6 - EXISTING FLOOR PLAN
1/4" = 1'-0"
UNIT 3-2.6 - REFLECTED CEILING PLAN
1/4" = 1'-0"
REMOVE DRYWALL @
WALLS IN BATHROOM
REMOVE AT UN -SHADED AF
-CARPET FLOORING
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
REMOVE AT SHADED AREA:
-CABINETS
-COUNTERTOPS
-APPLIANCES
-SHEET VINYL FLOORING
-PLUMBING FIXTURES
-ELECTRICAL SWITCHES
-ELECTRICAL OUTLETS
-ELECTRICAL FIXTURES
-TUB AND SHOWER SURROI
-DASHED ITEMS
UNIT 3-2.6 - DEMO FLOOR PLAN
1/4" = 1'-0"
J
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
429
lf==F �427]
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
431
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
410
REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS.
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
LIVING ROOM BEDROOM 1
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
403
:B:P TH
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
fT
/
414
NEW PORCELAIN TOILET, WHITE
425
426
EA:
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
425
x
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
>f7
432
4 3-80 DBEDROOM 1
435
CTO CTO
Lu
a
=433
3
�2
407
0
G')
410
I
=402
BEDROOM 2
JND
435=
401
—CLO
WIC/ -
414
I
OO �—
415
416
O O
=420
W
A3-80 2
=422
421
1 BEDROOM 2
UNIT 3-2.6 - DEMO FLOOR PLAN
1/4" = 1'-0"
J
NOTE: IN THE EVENT DRYWALL IS REMOVED AT ANY CEILING OR
WALL LOCATION, IT MUST BE EVALUATED BY THE ARCHITECT OF
RECORD IN ORDER TO DETERMINE IF IT IS PART OF A FIRE RATED
SYSTEM. IF IT IS DETERMINED TO BE PART OFA FIRE RATED
SYSTEM, THEN THE ARCHITECT WILL SPECIFY AN APPROPRIATE
REPAIR.
429
lf==F �427]
UNIT 3-2.6 - PROPOSED FINISH PLAN
1/4" = 1'-0"
❑ UNIT 3-2.6 (BASEMENT ONLY)
KEY PLAN
I WALL TYPES LEGEND I
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
D EXHAUST FAN
SMOKE/ CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
I GENERAL UNIT PLAN NOTES: I
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
431
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
410
REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS.
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
403
:B:P TH
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
NEW GARBAGE DISPOSAL
414
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
415
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
425
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
434
432
4 3-80 DBEDROOM 1
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
Lu
a
=433
3
�2
407
0
G')
410
I
=402
435=
401
—CLO
405=
414
I
415
416
=420
W
A3-80 2
=422
421
1 BEDROOM 2
a?'I
418
� o
°
419
000
UNIT 3-2.6 - PROPOSED FINISH PLAN
1/4" = 1'-0"
❑ UNIT 3-2.6 (BASEMENT ONLY)
KEY PLAN
I WALL TYPES LEGEND I
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
NEW PARTITION
ELECTRICAL SYMBOLS
D EXHAUST FAN
SMOKE/ CARBON MONOXIDE DETECTOR
SD
SURFACE MOUNTED LIGHT FIXTURE
Q WALL MOUNTED LIGHT FIXTURE
CEILING FAN
I GENERAL UNIT PLAN NOTES: I
1. IF EXISTING UNIT CONDITIONS VARY FROM WHAT IS SHOWN ON ARCHITECTURAL
DRAWINGS, CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO SHEET A3-800 FOR OVERALL UNIT FINISHES AND UNIT FINISH PLAN NOTES.
3. EXISTING UNIT LIGHTING CONDITIONS, FIXTURE TYPES, AND LOCATIONS MAY VARY.
FIELD VERIFY LOCATIONS AND FIXTURE TYPES.
4. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND DOOR SIZES.
5. GC TO PROVIDE UNIT PRICING FOR BASEBOARD HEATER COVER REPLACEMENT.
6. GC TO REPLACE ALL CEILING FANS AT KITCHENS/DINING ROOMS WITH SURFACE
MOUNTED LIGHT FIXTURE U.N.O.
UNIT INTERIORS - SCHEDULE
NO. DESCRIPTION
401
LUXURY VINYL TILE FLOORING, ASHLAR INSTALLATION. ADD
1/4 ROUND RUBBER BASE AT ALL LOCATIONS WHERE CPT.
WAS DEMOLISHED (TYP.)
402
CARPET FLOORING W/ RUBBER TRANSITION STRIPS.
403
RUBBER BASE, SQUARE PROFILE (@ KITCHEN AND BATH)
405
REPAINT ALL CLOSET SHELVES
407
PAINT WALLS AND CEILING
410
REPLACE ALL THRESHOLDS AT UNIT ENTRY DOORS.
414
PLASTIC LAMINATED COUNTER TOPS
415
NEW BASE CABINETS W/ CABINET PULLS
416
NEW UPPER CABINETS W/ CABINET PULLS
418
NEW BLACK ELECTRIC RANGE
419
NEW BLACK OVER -RANGE MICROWAVE
420
NEW BLACK DISHWASHER
421
NEW STAINLESS STEEL DROP-IN SINGLE -BOWL SINK W/
SINGLE FAUCET HOLE
422
REPLACE W/ NEW S.S. ONE -HANDLE, PULL DOWN FAUCET
423
NEW GARBAGE DISPOSAL
424
NEW PORCELAIN TOILET, WHITE
425
NEW DROP-IN PORCELAIN SINK BOWL, WHITE
426
NEW CHROME SINK FAUCET
427
NEW MULTI -PIECE FIBERGLASS TUB & SHOWER SURROUND
429
NEW CHROME BATH/SHOWER TRIM & SHOWER VALVE
431
NEW CHROME BATH ACCESSORIES
432
NEW FRAMELESS, MIRRORED MEDICINE CABINETS.
433
NEW VANITY LIGHT FIXTURE
434
REPLACE ALL LIGHT FIXTURES
435
REPLACE ALL LIGHT SWITCHES AND OUTLETS. EXISTING
WIRING TO REMAIN U.N.O.
hK Cp�o
ERIC C o
Lu
U)
0
0
0
L
a
0
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
0
c
\an9 DN`s•
r�
V
Z
a
Q
a
J_
a
z
W
W
00
z a c(D
�
WL
U
L 0 N
• �--�
0.
o °co
M
W
O w o
F-�---I
OM
v O
T
D
0
C)
/ pbotl Asso
6�9� caeN\
0
c
\an9 DN`s•
r�
V
Z
Q
a
J_
z
W
W
�
WL
N
M
0.
M
~
Q
o
D
0
C)
0
W
/1
�
Q
W
(D
Q
J
Q
H
Dp
p
Z
W
Lu
a
co
�2
D
0
G')
19-016
69:Igilr►C•a
A3-309
SOUTH - EXISTING
J 1/8" = 1'-0"
ROOF
116' - 9
LEVEL 2
108'- "
LEVEL
100' - 0"
BASEMENT
92' - 0"
BEAST - EXISTING
v % 1/8" = 1'-0"
BASEMEN
92' - 0"
1
9..
2
9
NORTH - EXISTING
1/8" = 1'-0"
�z -u Y
WEST - EXISTING
1/8" = 1'-0"
EXTERIOR MATERIAL SCHEDULE
NO. DESCRIPTION
211
EXISTING DOORS (AND WINDOWS, WHERE OCCURS)
AT BUILDING ENTRIES TO BE DEMOLISHED (TYP.)
214
EXISTING BRICK WALLS AT BUILDING ENTRY STOOPS
TO BE REPAIRED, V.I.F. IF NECESSARY (TYP.)
217
ALL EXTERIOR UNIT STOOPS & PATIOS TO BE
DEMOLISHED (TYP.)
219
EXISTING BALCONY GUARDRAILS TO BE
DEMOLISHED (TYP.)
222
EXISTING LIGHT FIXTURE AT BALCONIES TO BE
REPLACED (TYP.) RE: FINISH SCHEDULE
224
EXISTING BUILDING ADDRESS NUMBERS TO BE
DEMOLISHED (TYP.)
228
EXISTING METAL GUARDRAIL AT EXTERIOR
BASEMENT STAIRS TO BE DEMOLISHED.
F --
Lu
U)
Z p
O O
� 0
aW
UQ
C)o
Lu a_
o�
N
0
N
W
0
PLAN DATES
a
a
00
z�c(o
W 0 N
• 0co
WO w
Oo00
M
- LoO
11 ,, x � cD
T
V J
es pbotl Asso
6�9� caeN\
/
e��7aipa D``1`�`oc
r�
V
Z
c/)
z
0
J
Q
Lu
J
W
W
0
0.
M
CIOLu
�
O
w
LU
0
Z
Qw
Q
�p
X
w
co
W<
co
cD
Qrn
Lu
=
0
C)
19-016
SHEET
NO.
A3-401
NEW LIGHT
NEW ALUM.
FRONT ENTI
1►1��1�11d1�:
LEVEL 1
100' - 0"
ENLARGED EAST BUILDING ENTRY
1/411 = 1'-0"
6'-0"VIF
EXISTING R.O.
ROOF
116' - 9"
NEW METAL ROOFING
NEW TRIM BOARD, PTD.
w/ ACCENT COLOR
ALUMINUM STOREFRONT
ENTRY
1181.9 Lel
NEW BUILDING
ENTRY LIGHTING
NEW EXTERIOR
ARYLIC BUILDING
SIGNAGE
ADA PUSH -ASSIST \
DOOR OPEN BUTTON
NEW MTL. WIRE
MESH HANDRAIL
LEVEL 1
1001-0 "
ENLARGED NORTH BUILDING ENTRY
1/4" = 1'-0"
5
NORTH - PROPOSED ELEVATION
1/8" = 1'-0"
IrPM&I
E223]
z�i_2_1
LEVEL
loo. -O.-
210 -
209
00'-0"210-
209 1
SOUTH - PROPOSED ELEVATION
2 % 1/8" = 1'-0"
ROOF
116' - 9"
LEVEL 2
108'
_9 9"
LEVEL0
" 1
100' -
WEST -PROPOSED
4 % 1/8" = 1'-0"
ROOF
116' - 9"
EVEL 2
108' - 9"
EVEL1
100' - 0"
GENERAL EXTERIOR RENOVATION NOTES:
1. EXISTING CONDITIONS OF EXTERIOR MAY VARY - IF EXTERIOR
CONDITIONS VARY FROM WHAT IS SHOWN IN ARCHITECTURAL DRAWINGS,
CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO EXTERIOR PAINT SCHEDULE FOR SPECIFIC PAINT TYPES AND
LOCATIONS.
3. REPAIR OR REPLACE ANY DAMAGED MATERIALS THAT HAVE BEEN NOTED
TO REMAIN ON PLANS. V.I.F. IF NECESSARY.
EXTERIOR PAINT SCHEDULE
NO. MANUFACTURER MODEL COLOR COMMENTS
PT -1
n
SW 7045
'INTELLECT
SIDING PAINT COLOR
BERRIDGE 'DEEP DECK' VERTICAL METAL PANEL, "DARK
BRONZE" COLOR, TO BE INSTALLED ON ALL MANSARDS.
UAL GREY'
INSTALL OVER #30 FELT OVER THE TOP OF EXISTING
PT -2
SHERWIN WILLIAMS
NORTH - PROPOSED ELEVATION
1/8" = 1'-0"
IrPM&I
E223]
z�i_2_1
LEVEL
loo. -O.-
210 -
209
00'-0"210-
209 1
SOUTH - PROPOSED ELEVATION
2 % 1/8" = 1'-0"
ROOF
116' - 9"
LEVEL 2
108'
_9 9"
LEVEL0
" 1
100' -
WEST -PROPOSED
4 % 1/8" = 1'-0"
ROOF
116' - 9"
EVEL 2
108' - 9"
EVEL1
100' - 0"
GENERAL EXTERIOR RENOVATION NOTES:
1. EXISTING CONDITIONS OF EXTERIOR MAY VARY - IF EXTERIOR
CONDITIONS VARY FROM WHAT IS SHOWN IN ARCHITECTURAL DRAWINGS,
CONTACT ARCHITECT FOR FURTHER CLARIFICATION & SCOPE.
2. REFER TO EXTERIOR PAINT SCHEDULE FOR SPECIFIC PAINT TYPES AND
LOCATIONS.
3. REPAIR OR REPLACE ANY DAMAGED MATERIALS THAT HAVE BEEN NOTED
TO REMAIN ON PLANS. V.I.F. IF NECESSARY.
EXTERIOR PAINT SCHEDULE
NO. MANUFACTURER MODEL COLOR COMMENTS
PT -1
SHERWIN WILLIAMS
SW 7045
'INTELLECT
SIDING PAINT COLOR
BERRIDGE 'DEEP DECK' VERTICAL METAL PANEL, "DARK
BRONZE" COLOR, TO BE INSTALLED ON ALL MANSARDS.
UAL GREY'
INSTALL OVER #30 FELT OVER THE TOP OF EXISTING
PT -2
SHERWIN WILLIAMS
SW 7645
'THUNDER
EXTERIOR TRIM
COLOR, TO BE INSTALLED AS FASCIA PANEL AT TOP OF
��
��//J
V
W
MANSARDS. INSTALL OVER EXISTING CONDITIONS
GREY'
(TYP.)
PT -3
SHERWIN WILLIAMS
SW 7645
'THUNDER
GUTTERS &
EXISTING BRICKVENEER TO REMAIN (TYP.)
210
EXISTING BRICK ROWLOCK SILL TO REMAIN (TYP.)
GREY'
DOWNSPOUTS
PT -4
SHERWIN WILLIAMS
SW 6424
'TANSY
SOFFITS & MANSARD
WINDOW SCHEDULE.
213
EXISTING ENTRY STOOPS TO BE DEMOLISHED &
GREEN'
COLOR
PT -5
SHERWIN WILLIAMS
SW 6258
'TRICORN
EXTERIOR METALS
RAIL AT BOTH SIDES OF STAIRS & PAINTED, PT -5. RE:
EXTERIOR PAINT SCHEDULE. (TYP.)
BLACK'
NEW METAL GUARDRAIL TO BE INSTALLED AT ALL
EXTERIOR MATERIAL SCHEDULE
NO. DESCRIPTION
201
NEW PRE -FINISHED GUTTERS & DOWN SPOUTS, (TYP.)
a
PT -3. RE: EXTERIOR PAINT SCHEDULE.
202
BERRIDGE 'DEEP DECK' VERTICAL METAL PANEL, "DARK
BRONZE" COLOR, TO BE INSTALLED ON ALL MANSARDS.
a
INSTALL OVER #30 FELT OVER THE TOP OF EXISTING
`Q0(
ASPHALT SHINGLES (TYP.)
203
BERRIDGE FASCIA METAL PANEL, "DARK BRONZE"
-
COLOR, TO BE INSTALLED AS FASCIA PANEL AT TOP OF
��
��//J
V
W
MANSARDS. INSTALL OVER EXISTING CONDITIONS
z�c(o
(TYP.)
208
EXISTING VERTICAL SIDING TO BE REPAINTED, PT -1.
• �--�
RE: EXTERIOR PAINT SCHEDULE.
209
EXISTING BRICKVENEER TO REMAIN (TYP.)
210
EXISTING BRICK ROWLOCK SILL TO REMAIN (TYP.)
212
NEW ALUM. STOREFRONT SYSTEM TO BE INSTALLED
M
O
°) o
WITHIN EXISTING ROUGH OPENING OF ENTRY DOOR
(AND WINDOW, WHERE OCCURS). RE: ARCH DOOR &
WINDOW SCHEDULE.
213
EXISTING ENTRY STOOPS TO BE DEMOLISHED &
REBUILT (TYP.)
218
NEW CONCRETE STOOPS & PATIOS TO BE INSTALLED
AT ALL 1 ST FLOOR UNITS. PROVIDE +36" MTL. HAND
RAIL AT BOTH SIDES OF STAIRS & PAINTED, PT -5. RE:
EXTERIOR PAINT SCHEDULE. (TYP.)
220
NEW METAL GUARDRAIL TO BE INSTALLED AT ALL
SECOND FLOOR BALCONIES & PAINTED, PT -5. RE:
EXTERIOR PAINT SCHEDULE.
221
ADDITIONAL EXTERIOR PATIO LIGHT TO BE INSTALLED
AT ALL EXTERIOR UNIT PATIO DOORS (TYP.)
223
NEW WALL MTD. EXTERIOR LIGHT FIXTURES TO BE
INSTALLED AT ALL BUILDING ENTRIES (TYP.)
225
NEW TWO -TONED EXTERIOR ACRYLIC BUILDING
SIGNAGE. RE: ENLARGED EXTERIOR ENTRY FOR
DETAILS
257
NEW WHITE VINYL CASEMENT WINDOW AT TYPE 'A'
UNITS (TYP.)
258
NEW CONCRETE PATIO & RAILING AT TYPE 'A' UNITS.
RE: A3-604 FOR DETAILS.
V V Y V V V
A 12 3/4"
6 1/2" CL6 1/4"
1" BREVIA
FONT, COLOR -1
31/2"HELVETICA 0
FONT, COLOR -2
1" BREVIA
FONT, COLOR -1
EXTERIOR BUILDING SIGNAGE
1 1/2" = 1'-0"
�yyw
SO
W=
Lu
U)
0
O
0
Lu
a
PLAN DATES
0
Q
>
a
LU
W
Q
LuJ
a
0
`Q0(
W
Q
co M X
-
00
��
��//J
V
W
�
�Q
z�c(o
L
co
U
W 0 N
• �--�
0
o °co
WE_qO
w 0
V x
M
O
°) o
/ pbotl Asso
6�9� caeN\
i
0
c
\an9 DN`s•
V C7
Z
0
Q
>
J
LU
W
Q
LuJ
I
0
Lu
W
Q
co M X
Q
0 W
co 0
19-016
69:Igilr►C•]
A3-402
W
o
LU
��v//��
VJ
Q
O
Lu
CD
a
0
Q
~
c
0
�
a
��
��//J
V
W
�
�Q
L
co
0
19-016
69:Igilr►C•]
A3-402
2x4 STL. ANGLED TOP RAIL
1 1/2" 0 STD STL. PIPE HANDRAIL. WELD
ALL JOINTS AND GRIND SMOOTH (PAINT)
STL. WIRE MESH WITH 1x2 OPENINGS
2x2 STL. TUBE BALUSTERS WITH 1
1/2 x 1 1/2 STL. ANGLE WELDED (w/
WIRE MESH PANELS.) ALL JOINTS TO
BE GRIND SMOOTH (PAINT)
I
x
D
Z
I
T.O. SLAB
ELEV. VARIES
CONCRETE SLAB RE:
STRUCTURAL PLANS
1 1/2',, 2", T1 1/2"
01 nil nnInI
RAMP AND GUARDRAIL SECTION DETAIL
1" = 1'-0"
5'-4"
1 1/2 2", T1 1/2"
RAMP GUARDRAIL ELEVATION DETAIL
1" = 1'-0"
3
5' - 4"
001
STL. ANGLED TOP RAIL
?" 0 STD STL. PIPE HANDRAIL WELD
JOINTS & GRIND SMOOTH (PAINT)
WIRE MESH WITH 1x2 OPENINGS
STL. TUBE BALUSTERS WITH 1 1/2x1
3TL. ANGLE WELDED (w/ WIRE
3H PANELS.) ALL JOINTS TO BE
VD SMOOTH (PAINT)
T.O. SLAB
ELEV. VARIES
JCRETE WALL RE:
UCTURAL PLANS
1 1/2 2 1 1/2"
I III III 'III- ii1—' 1 I -r- I 1 1-1 1 1
1 1/2" 0 STD STL. PIPE HAN
ALL JOINTS & GRIND SMO(
of nil 7i - nil
ENLARGED RAMP PLAN
1/2" = 1'-0"
F --
Lu
J)
0
O
0
Lu
a
PLAN DATES
a
(D
a
00
J_
zcl�((o
OJ
a
U
L N
q
o °co
W
O w o
M
O
O
Lu
W
C /wT
�I J
o
O.
co
Oo
Z
co
J_
Q
C)0
0�
U)
;
y
SIDE STAIR RAILING DETAIL
1" = 1'-0"
?" 0 STD STEEL
HANDRAIL
WIRE MESH WITH
OPENINGS
?x STL. TUBE
LISTER
?" x 1 1/2" STL. ANGLE
USTERS (W/ WIRE
3H PANELS) WELDED
XISTING STL.
.UMNS. ALL JOINTS TO
GRIND SMOOTH (PAINT)
'E: FIELD PAINT ALL
EL RAILINGS & POSTS
LEVI
ELEVATION V
LEVI
ELEVATION V.I.F
STAIR RAILING DETAIL
1" = 1'-0"
2" 0 STD STEEL PIPE HANDRAIL
3'-0" ABOVE TREADS
WIRE MESH WITH 1x2 OPENINGS
2x STL. TUBE BALUSTER
2" x 1 1/2" STL. ANGLE BALUSTERS
WIRE MESH PANELS) WELDED TO
STING STL. COLUMNS. ALL JOINTS
BE GRIND SMOOTH (PAINT)
fE: FIELD PAINT ALL
EL RAILINGS & POSTS
hK Cp�o
ERIC C o
74
J)
p OF
U FF
LU co
W
H 0 Z)
Q U M
a 0z
co N
N �
O N
N O
� N
� Ln
PLAN DATES
/ Pbbott Asso
6�9� caeN\
0
c
\an9 DN`s•
co
V
Z
W
VJ
19-016
69:IqM11r►C6]
A3-602
a
a
,Qo
00
z 0 (D
OJ
o
Lu N
W
w
"wo
O � M
v O
C /wT
�I J
/ Pbbott Asso
6�9� caeN\
0
c
\an9 DN`s•
co
V
Z
W
VJ
19-016
69:IqM11r►C6]
A3-602
0
PATIO FLUSH AT DOOR
FINISH FLOOR
LEVEL 1
100' - 0"
d -
CONC. PATIO8- w
SLOPE AT 1/4" PER FOOT AWAY FROM BUILDING—
;_, e
-CONC. PATIO W/ TURNDOWN EDGE
RE:1/S3 101 SIMILAR
CONC. HAUNCH TO CONNECT
TO EXISTING BUILDING FOUNDATI
RE:3/S3-100SIMILAFZ
i it l li�i i it 1 1
TYPE W PATIO SECTION
1" = 1'-0"
J_
U
Lu
m
M
w
691�G1Q[e3��C•]���G\Iq
7 GAUGE (3/16") STL. WIRE
MESH WITH 1x2 OPENINGS
3X3 STL. TUBE POST
ATTACH TO CONC.
PATIO W/ STL. PLATE
2x2 STL. ANGLE FRAME w/ 1x2 WIRE MESH
WELDED TO 3x3 STL. BALUSTERS. ALL
JOINTS TO BE GRIND SMOOTH (PAINT)
NOTE: FIELD PAINT ALL
STEEL RAILINGS & POSTS
NOTE: FIELD PAINT ALL
STEEL RAILINGS & POSTS
3X3 STL. TUBE POST
ATTACH TO CONC.
PATIO W/ STL. PLATE
2x2 STL. ANGLE FRAME w/ 1x2
WIRE MESH WELDED TO 3x3
STL. TUBE POST. ALL JOINTS
TO BE GRIND SMOOTH (PAINT)
7 GAUGE (3/16") STL. WIRE
MESH WITH 1x2 OPENINGS
ALL RAILINGS AT TYPE W PATIOS
TO BE +42" ABOVE FINISH PATIO
SURFACE
(N) CONC.
E
41 - 011
4'-0"
64
a
8
J
a
Q
,Q0
M
O
U
p
mt
zcl�c(o
o
0
F
O
o 0 co
W
vil
LLQ
0
/
�/1
W
V M
O
� CD
1 ,
T
L
co
Q
w
m
Lu
A d-,
p
-
�
J_
U
Lu
m
M
w
691�G1Q[e3��C•]���G\Iq
7 GAUGE (3/16") STL. WIRE
MESH WITH 1x2 OPENINGS
3X3 STL. TUBE POST
ATTACH TO CONC.
PATIO W/ STL. PLATE
2x2 STL. ANGLE FRAME w/ 1x2 WIRE MESH
WELDED TO 3x3 STL. BALUSTERS. ALL
JOINTS TO BE GRIND SMOOTH (PAINT)
NOTE: FIELD PAINT ALL
STEEL RAILINGS & POSTS
NOTE: FIELD PAINT ALL
STEEL RAILINGS & POSTS
3X3 STL. TUBE POST
ATTACH TO CONC.
PATIO W/ STL. PLATE
2x2 STL. ANGLE FRAME w/ 1x2
WIRE MESH WELDED TO 3x3
STL. TUBE POST. ALL JOINTS
TO BE GRIND SMOOTH (PAINT)
7 GAUGE (3/16") STL. WIRE
MESH WITH 1x2 OPENINGS
ALL RAILINGS AT TYPE W PATIOS
TO BE +42" ABOVE FINISH PATIO
SURFACE
(N) CONC.
E
41 - 011
4'-0"
64
PATIO FLUSH J
AT DOOR
THRESHOLD
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN LIVING ROOM
UNIT TYPE 3-2.4 - TYPE A PATIO DETAIL
1" = 1'-0"
I
hK Cp�o
ERIC C o
74
Lu
a
J
a
Q
,Q0
M
O
U
p
mt
zcl�c(o
o
U
F
O
o 0 co
W
d
LLQ
0
/
�/1
W
V M
O
� CD
1 ,
T
L
co
Q
w
m
Lu
A d-,
p
-
�
¢
W
M
0
o
o
¢
co
N
a
e.
4°
-
.dtfi-
n.
14
=
a;
-. °
-d `
'PATIO d
-
a d:._
o
44-a:a
Lu.e�.
d' e
d.
d
d
O
a ,
d
u)
d,e
.d
d
-
n d
d `
8
PATIO FLUSH J
AT DOOR
THRESHOLD
EXISTING WALL TO REMAIN
EXISTING DOOR TO REMAIN LIVING ROOM
UNIT TYPE 3-2.4 - TYPE A PATIO DETAIL
1" = 1'-0"
I
hK Cp�o
ERIC C o
74
Lu
a
J
a
Q
,Q0
M
O
U
p
0
zcl�c(o
o
U
F
O
o 0 co
W
(j W 0
LLQ
0
/
�/1
W
V M
O
� CD
1 ,
T
L
co
Q
w
m
Lu
p
�
¢
W
M
0
o
o
¢
co
N
PLAN DATES
/ Pbbott Asso
6�9� caeN\
0
C
\ana 500
W
a
M
a
Q
,Q0
M
O
00
0
zcl�c(o
U
W 0 N
• 1--�
o 0 co
W
(j W 0
LLQ
0
/
�/1
W
V M
O
� CD
1 ,
T
L
co
Q
rn=
LU
cD
0
/ Pbbott Asso
6�9� caeN\
0
C
\ana 500
W
M
Q
M
O
00
0
;J
I..L
CD
0
�
LLQ
0
/
�/1
W
�
�Q
L
co
Q
rn=
LU
cD
0
19-016
A3-604
SECTION AT TYPICAL ROLL -IN SHOWER
1 112" = 1'-U"
ROD TO BE
D AT ALL
SHOWERS
WINATION BAR
TRIP AT ALL EXPOSED
ES ON WALLS (TYP.)
SURROUND TO BE TILE AT
LOCATIONS W/ WINDOW. IF
OW, SHOWER SURROUND TO
1ANUFACTURED FIBER GLASS.
ADDITIONAL LAYER OF
'X' GYP. BIRD. AT ALL
(ALL ASSEMBLIES. RE:
=D PLANS FOR DETAILS
TIOUS BACKER
O SIT ON FLANGE
/ER SURROUND (TYP.)
UFACTURED SHOWER PAN.
RGED PLANS FOR SIZE
DRAIN, RE: PLUMBING
ATION & SIZE
.00R MATERIAL TO BE SLOPED
- OF SHOWER PAN AT 1/4" PER
FOOT. 5/8" TILE ON 1/4" MORTAR BED
ON 1/8" DECOUPLING MEMBRANE
42" MIN
6" 36" MIN
MINIMUM
REINFORCED AREA
EVEN LARGER REINFORCING r///
PREFERRED FOR L�
GREATER EASE WHEN �1-
ADDITIONAL 2" MIN.
EACH SIDE AND
BOTTOM RECOMMENDED
TO MOUNT 24" LONG
STANDARD GRAB BAR
MINIMUM REINFORCING BEHIND TOILETS
LOCATED BESIDE A WALL
IF THIS DIMENSION IS LESS
THAN 12", THEN THE 42" MIN.
MUST BE CORRESPONDINGLY
LONGER
TO ACCOMMODATE A 24"
BAR, THE REINFORCED AREA
SHOULD BE 28" TO 32" LONG
TO PROVIDE FULL SUPPORT
FOR THE MOUNTING PLATES
MINIMUM
REINFORCED AREA
2"- 4" ADDITIONAL
REINFOREING AT SIDES
AND BOTTOM RECOMMENDER
W
>
0-
0 -
LU
0
Lu
Lu
O
x
m
54" MIN
12" 42" MIN
MAX
3911-4111
z
ro
MINIMUM REINFORCING ADJACENT TO TOILETS
LOCATED BESIDE A WALL
MIN. REINFORCING AT TOILETS
1/2"
GENERAL ACCESSIBLE SHOWER NOTES:
1. ADD WATER DIVERTER CONTROL FOR USE BETWEEN
BOTH FIXED AND HAND-HELD SHOWER HEADS.
2. ALL SHOWER CONTROLS SHALL BE OPERABLE WITH
ONE HAND AND SHALL NOT REQUIRE TIGHT GRAPSING,
PINCHING, OR TWISTING OF THE WRIST.
3. SHOWER PAN THRESHOLDS CANNOT EXCEED 1/2"
TRANSITION AT FINISH FLOOR MATERIAL.
4. PROVIDE SHOWER CURTAIN ROD AT ALL ROLL -IN SHOWERS.
SHOWER PAN WIDTH VARIES
RE: UNIT PLANS
HAND-HELD SHOWER & CONTROLS
16" - 27" FROM EDGE OF SEAT WALL
2 1/2" 15" - 16"
MAX.
SHOWER SEAT 4
ml�g
STANDARD ROLL IN SHOWER PLAN
STANDARD ROLL -IN ACCESSIBLE SHOWER
REMOVABLE BATHROOM CABINET ISOMETRIC
TROL WALL
o
0
F W
F - - -- -1
U
z
0
V)W
�
¢
>
m
z
O
STANDARD ROLL IN SHOWER PLAN
STANDARD ROLL -IN ACCESSIBLE SHOWER
REMOVABLE BATHROOM CABINET ISOMETRIC
o
0
F W
F - - -- -1
U
z
PLAN DATES
�
¢
>
m
z
O
I
Lu
W
=
Lu
W
=
O
o
Z
O
¢
J
LL
F
¢
z
a
Lux
-
Z
m
w
cC
w
3:z
=
U
w
x
W
W
W
O
w
F
z
w
U
L J
z 0 (D
OJ
60" MIN. FLOOR CLEARANCE AT SHOWER
o�
STANDARD ROLL IN SHOWER PLAN
STANDARD ROLL -IN ACCESSIBLE SHOWER
REMOVABLE BATHROOM CABINET ISOMETRIC
EQ t EQ
1 1/2" CURTAIN ROD
SHOWER DEPTH VARIES
RE: UNIT PLANS
END WALL ELEVATION
z
z
O U
z
O
Z
O w
Z m
Lu
m m
m
¢ Q
m
m c(9
(� <
z
0
ch
x
W
x
0
O
z
Z)
U
m
Lu
O
2
m
K
Lu
0
O
2
m
K
O
m
J
O
m
f -
Z
O
U
O
O
W
Lu
Lu
0
O
2
Lu
>
O
m
M
v
ro
m
co
K
U0
OLL
=: =
Urnw
Z—
Lu
FSO
Z ,n
HAND-HELD SHOWER & CONTROLS
16" - 27" FROM EDGE OF SEAT WALL
4
LU
m
m
LU
O
x
m
DOORS.
rm
o
0
F - - -- -1
W
PLAN DATES
�
¢
>
m
z
O
I
� U
W
=
Lu
J
w
W
=
Lu
C/)
Z
O
¢
X
CL
Z)
0
mz
Z)
m
m
Lu
_
U
a
Lux
-
Z
m
w
cC
w
3:z
=
U
w
x
W
W
W
O
w
F
z
w
U
z 0 (D
OJ
COORDINATE WATER FEED
o�
¢
HOSE LOCATION WITH WINDOW
io
w
EQ t EQ
1 1/2" CURTAIN ROD
SHOWER DEPTH VARIES
RE: UNIT PLANS
END WALL ELEVATION
z
z
O U
z
O
Z
O w
Z m
Lu
m m
m
¢ Q
m
m c(9
(� <
z
0
ch
x
W
x
0
O
z
Z)
U
m
Lu
O
2
m
K
Lu
0
O
2
m
K
O
m
J
O
m
f -
Z
O
U
O
O
W
Lu
Lu
0
O
2
Lu
>
O
m
M
v
ro
m
co
K
U0
OLL
=: =
Urnw
Z—
Lu
FSO
Z ,n
HAND-HELD SHOWER & CONTROLS
16" - 27" FROM EDGE OF SEAT WALL
4
LU
m
m
LU
O
x
m
DOORS.
rm
o
0
F - - -- -1
PLAN DATES
- - - -----------J
J_
I
� U
J
uj
a
C/)
JT
;ABINETo
D
W
WINDOW, WHERE OCCURS.
z 0 (D
OJ
COORDINATE WATER FEED
Lu W N
HOSE LOCATION WITH WINDOW
C
w
"wmO
ADD BLOCKING THIS LOCATION
Q
� M
FOR FUTURE INSTALLATION OF
x
LQ
0)()
SHOWER SEAT
11
SHOWER WIDTH VARIES
RE: UNIT PLANS
CONTROL WALL ELEVATION
hK Cp�o
ERIC C o
E
4? 174
W=
Lu
Lu
0
O
0
Lu
a
JT
CTION
o
0
W
PLAN DATES
RANCE
J_
I
� U
S
uj
a
C/)
JT
;ABINETo
`� W
O
z 0 (D
OJ
Q
Lu W N
LU0
w
"wmO
Q
� M
w
x
LQ
0)()
11
W<
T,,
coLo
V J
z
z
O U
-z
O
m Z
O w
Z m
E] m
m
mm
¢ Q
m
m c�9
(7 2
z
_o
ch
/ pbott Asso
6�9� caeN\
0
c
\an9 DN`s•
J
0
W
J_
I
m
uj
C/)
co
Lij
O
co
Q
LU0
Q
LLJ
w
co
z
W<
coLo
0
U(�:m
19-016
69:Iq011r►Co]
A3-606
a
0
N
(`�
(`�
O
N
O
N
r
N
V
a
N
(`�
(`�
O
N
O
N
r
N
V
Q
N
N
M
M
O
r
r
N
O
N
ti
N
I
LEVEL 2 - PROPOSED FINISH PLAN
1/811 = 1'-0"
CORRIDOR FLOORING SCHEDULE
ey Description Manufacture Series Pattern Color Size Comments
1
OVERALL ACCENT
SHAW CONTRACT
ACTIVE
ADVANCE TILE
'ABILITY'
12" x 48"
a
O
FLOORING
O
—
00
2
UNIT ENTRY
SHAW CONTRACT
ACTIVE
DASH TILE
'ABILITY'
12" x 48"
TILE TO BE CUT
ACCENT COLOR 2
O w M
OM
v O
DOWN TO 12" x 24"
3
UNIT ENTRY
SHAW CONTRACT
ACTIVE
TRACK TILE
'ABILITY'
12" x 48"
TILE TO BE CUT
c
ACCENT COLOR 2
W
U)
DOWN TO 12" x 36"
JY
JY
LEVEL 1 - PROPOSED FINISH PLAN
1/811 = 1'-0"
CPT -1
5' - 4"
NIT ENTRY ACC T FLOOR PATTERN
ALIGN TO EDGE DOOR FRAME
3'-4" 1 2'-0"
CPT -1
CPT -1 —F
PT
CPT -1
CPT -2
CPT -1
CPT -1
UNIT ENTRY ACCENT
FLOOR PATTERN
OVERALL ACCENT
FLOORING PATTERN
CPT -1
UNIT ENTRY - TYPICAL FLOOR PATTERN
1/2" = 1'-0"
hK Cp�o
ERIC C o
F --
LU
J)
0
O
0
LU
0
a
0
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
/
O
C
\an9 DN`s•
��
V
Z
a
Z
.1
n
J
a
O
O
—
00
z�(D
M�
W
U
W 0 N
• �--�
I
o °co
W
O w M
OM
v O
r ^T
V J
Q
/ pbotl Asso
6�9� caeN\
/
O
C
\an9 DN`s•
��
V
Z
Z
.1
n
J
O
O
—
J
M�
W
Illy
I
O
W
Illy
Q
00
O
0
U
c
D
W
U)
;O �
Q
LU (D
J
�
co
i]
FyW
Z
W<
co
Qrn
=
(D
0
19-016
69:IqM11r►C•a
A3-801
PENDATNT ACCENT
LIGHT TO REPLACE
EXISTING FIXTURE
AT ATRIUM
BALCONY BALCONY
(N) CELING MOUNTED
LIGHT (TYP.)
LEVEL 2 RCP
1/811 = 1'-0"
BALCONY BALCON�
WALL MOUNTED
LIGHT (TYP.)
BALCONY
Mo _< WALL MOUNTED
LIGHT TYP s°`
(TYP.)
,sD- - - -- - - - - - - - - - - - - - - -TTI- - - -
LEVEL 1 RCP
1/811 = 1'-0"
Te
0
DUPLEX OUTLET
SINGLE POLE LIGHT SWITCH
O•
SMOKE DETECTOR
SD
`Q0(
O•
TT
CMD
-
00
UNIT 102
SURFACE MOUNTED LIGHT FIXTURE
UNIT 104
UNIT 106
3:- PL
PENDANT LIGHT FIXTURE
IT"108-
"UNIT
UNIT 110. .
WO
w
UNIT TYPE 3 2.4 -
00
Oo M
Loo
T
UNIT TYPE: 3-2.1
UNIT TYPE: 3 2.1
V J
UNIT TYPE: 3 2.1
O
UNIT TYPE:
/1
TYPE A'
QW
-.
RE: 4 /A3 303 ,'
0
-
„ RE: 4 /A3-303308
/1
Lu
Q
I
co
RE: 3 /A3-307 ;;'
W
0
U��m
it
17
LEVEL 1 RCP
1/811 = 1'-0"
hK Cp�o
ERIC C o
IT -
Lu
U)
0
0
0
Lu
¢
0
a
N
O
N
74
PLAN DATES
ELECTRICAL SYMBOLS
0
DUPLEX OUTLET
SINGLE POLE LIGHT SWITCH
O•
SMOKE DETECTOR
SD
`Q0(
O•
CARBON MONOXIDE DETECTOR
CMD
-
00
WALL MOUNTED EXIT SIGN
SURFACE MOUNTED LIGHT FIXTURE
o
WALL MOUNTED LIGHT FIXTURE
3:- PL
PENDANT LIGHT FIXTURE
hK Cp�o
ERIC C o
IT -
Lu
U)
0
0
0
Lu
¢
0
a
N
O
N
74
PLAN DATES
/ pbotl Asso
6�9� caeN\
/
O
C
\an9 DN`s•
)
c
Z
a
c/)V Q
a
z
a
Lu
U
`Q0(
m
-
00
z 0 �D
OJ
o
W N
n/
N
M
WO
w
M
O
00
Oo M
Loo
T
M
V J
/ pbotl Asso
6�9� caeN\
/
O
C
\an9 DN`s•
)
c
Z
c/)V Q
a
z
Lu
U
m
ry
i
O
n/
N
M
LL
M
O
O
U
M
D
O
W
/1
I..L
QW
Q
J
0
-
z
W
/1
Lu
Q
I
co
ui
W
0
U��m
19-016
69:Iq�r►C•]
A3-802
Q
N
M
CM
M
O
r
N
O
N
I -
C14
rLHJ I IU LHIVIINH I ED
COUNTER TOPS
NEW BLACK DISHWASHER
TUB/SHOWER W/ TILE
/A
lon
J
Ill
NEW STAINLESS STEEL
SURROUND W/
Luo
/
/
A
/
A
/
CEMENTITIOUS BACKER
DROP-IN SINGLE -BOWL SINK
�/ /
Q LU
I
BOARD AT TUB/SHOWER
QF CD(
NEW STAINLESS STEEL
DROP-IN SINGLE -BOWL SINK
W/ SINGLE FAUCET HOLE
w�
�
NEW PORCELAIN TOILET,
W/ SINGLE FAUCET HOLE
OP
/
WHITE
NEW BLACK ELECTRIC
RANGE
PLAN
DATES
U
I-�
BLIND CORNER CABINET
NEW CHROME TOILET PAPER
c� ERIC C o
FL
HOLDER
REQ'D IN TYPE'A' UNITS.
E
1
NEW FRAMELESS, MIRRORED
MEDICINE CABINETS.
4 174
NEW VANITY LIGHT FIXTURE
NEW CHROME SHOWER ROD
NEW DROP-IN PORCELAIN
D A
SINK BOWL, WHITE
NEW CHROME ROBE HOOK
a
NEW CHROME TOWEL BAR
TUB/SHOWER W/ TILE
NEW CHROME HAND TOWEL
,' NEW CHROME HAND
TOWEL
z
SURROUND W/
AR
BAR
>_
CEMENTITIOUS BACKER
LHSTIC LAMINATED
=r
BOARD AT TUB/SHOWER
C DOUNTER TOPS
oQ
o TUB/SHOWER W/ TILE
SURROUND W/
00
CEMENTITIOUS BACKER
,x
BOARD AT TUB/SHOWER
3' 2' - 6" 3'
I
5' -0"
♦'
UNIT 3-2.5 - BATHROOM 4
UNIT 3-2.5 - BATHROOM 3
UNIT 3-2.5
- BATHROOM 2
UNIT 3-2.5
-BATHROOM 1
Lu
1/4" = 1'-0"
1/4" = 1'-0"
1/4" = 1'-0"
�`JJ 1/4" = 1'-0"
PROVIDE 6" TRIM BOARD TO
COVER GAP BETWEEN TOP
OF CABINET AND CEILING
w
J)
FILLER
PROVIDE 6" TRIM BOARD TOO
NEW BLACKTOP -FREEZER
REFRIDGERATOR
Z0
O
CORNER 2' - 3" 2' - 0' 2' -
COVER GAP BETWEEN TOP
3" FI
3' - 3" 21-
6" 21- 6" 1' - 7 1/ '
NEW BLACK OVER -RANGE
a
w
w
C;ARINFT
OF CABINET AND CEILING
,,,,,_,,,.,., ,-
-
rLHJ I IU LHIVIINH I ED
COUNTER TOPS
NEW BLACK DISHWASHER
/A
lon
J
Ill
NEW STAINLESS STEEL
Luo
/
/
A
/
A
/
DROP-IN SINGLE -BOWL SINK
�/ /
Q LU
I
NEW STAINLESS STEEL
DROP-IN SINGLE -BOWL SINK
W/ SINGLE FAUCET HOLE
w�
�
o
o
W/ SINGLE FAUCET HOLE
V
/
NEW BLACK ELECTRIC
RANGE
PLAN
DATES
U
I-�
rLHJ I IU LHIVIINH I ED
COUNTER TOPS
NEW BLACK DISHWASHER
2' _6 1�-71/ 1-1
<0
I--
00
UNIT 3-2.5 - KITCHEN 2 UNIT 3-2.5 - KITCHEN 1 � wo8(D
1/4" = 1'-0" 1/4" = 1'-0"
• r� U 0000
W O w
O o
M
3-2.5 INTERIOR UNIT ELEVATIONS x O
v J Qtl
es pbotl Asso
6�9� caeN\
NEW CHROME SHOWER ROD NEW VANITY LIGHT FIXTURE
NEW CHROME TOWEL BAR NEW FRAMELESS, MIRRORED �''7diry9
REPLACE ALL WALL TILE IN MEDICINE CABINETS.
SHOWER. REFINISH EXISTING REPLACE ALL WALL TILE IN M
TUB WHERE REQ'D. SHOWER. REFINISH EXISTING
SEE FINISH SCHEDULES FOR TUB WHERE REQ'D.
Inr
TUB AND SHOWER GRAB BAR ° 7
LOCATION SEE FINISH SCHEDULES FOR f
� Z
TUB AND SHOWER GRAB BAR r<F
HEW CHROME TOILET PAPER _
LOCATION
ER
NEW PORCELAIN TOILET,
WHITE J
z
6 UNIT 3-2.4 (TYPE A) - BATHROOM 4 5UNIT 3-2.4 (TYPE A) - BATHROOM 3 UNIT 3-2.4 (TYPE A) - BATHROOM 2 UNIT 3-2.4 (TYPE A) - BATHROOM 1 D O_
1/411=11-011 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
Q
I
PROVIDE 6" TRIM BOARD TO Lu
COVER GAP BETWEEN TOP w J
PROVIDE 6" TRIM BOARD TO OF CABINET AND CEILING w
COVER GAP BETWEEN TOP SIDE-BY-SIDE M
OF CABINET AND CEILING REFRIDGERATOR/FREEZER O O
NEW STAINLESS STEEL W/ WATER & ICE DISPENSER
DROP-IN SINGLE -BOWL SINK @ ALL TYPE'A' UNITS. 0
FILLER W/ SINGLE FAUCET HOLE MICROWAVE TO BE
6" 2' - 0" 2' 6" 2' - 6" ORNE MOUNTED UNDER 34" 1' -L21-611L112 0
COUNTER TOP @ ALL TYPE 'A' in ' U z
D
/A
lon
J
Ill
L
Luo
/
/
/
v
/ �
o
�/ /
Q LU
I
2' _6 1�-71/ 1-1
<0
I--
00
UNIT 3-2.5 - KITCHEN 2 UNIT 3-2.5 - KITCHEN 1 � wo8(D
1/4" = 1'-0" 1/4" = 1'-0"
• r� U 0000
W O w
O o
M
3-2.5 INTERIOR UNIT ELEVATIONS x O
v J Qtl
es pbotl Asso
6�9� caeN\
NEW CHROME SHOWER ROD NEW VANITY LIGHT FIXTURE
NEW CHROME TOWEL BAR NEW FRAMELESS, MIRRORED �''7diry9
REPLACE ALL WALL TILE IN MEDICINE CABINETS.
SHOWER. REFINISH EXISTING REPLACE ALL WALL TILE IN M
TUB WHERE REQ'D. SHOWER. REFINISH EXISTING
SEE FINISH SCHEDULES FOR TUB WHERE REQ'D.
Inr
TUB AND SHOWER GRAB BAR ° 7
LOCATION SEE FINISH SCHEDULES FOR f
� Z
TUB AND SHOWER GRAB BAR r<F
HEW CHROME TOILET PAPER _
LOCATION
ER
NEW PORCELAIN TOILET,
WHITE J
z
6 UNIT 3-2.4 (TYPE A) - BATHROOM 4 5UNIT 3-2.4 (TYPE A) - BATHROOM 3 UNIT 3-2.4 (TYPE A) - BATHROOM 2 UNIT 3-2.4 (TYPE A) - BATHROOM 1 D O_
1/411=11-011 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
Q
I
PROVIDE 6" TRIM BOARD TO Lu
COVER GAP BETWEEN TOP w J
PROVIDE 6" TRIM BOARD TO OF CABINET AND CEILING w
COVER GAP BETWEEN TOP SIDE-BY-SIDE M
OF CABINET AND CEILING REFRIDGERATOR/FREEZER O O
NEW STAINLESS STEEL W/ WATER & ICE DISPENSER
DROP-IN SINGLE -BOWL SINK @ ALL TYPE'A' UNITS. 0
FILLER W/ SINGLE FAUCET HOLE MICROWAVE TO BE
6" 2' - 0" 2' 6" 2' - 6" ORNE MOUNTED UNDER 34" 1' -L21-611L112 0
COUNTER TOP @ ALL TYPE 'A' in ' U z
D
/A
/AIll
Ill
11rv7o, i� "vm"' w •• •,.
COUNTER TOPS DROP-IN RANGE W/ FRONT
CONTROLS & HOOD ABOVE
Luo
/
/
/
v
/ �
o
�/ /
Q LU
I
NEW STAINLESS STEEL
DROP-IN SINGLE -BOWL SINK
W/ SINGLE FAUCET HOLE
w�
�
o
o
V
/
NEW BLACK ELECTRIC
RANGE
PLAN
DATES
U
I-�
BLIND CORNER CABINET
2' _6 1�-71/ 1-1
<0
I--
00
UNIT 3-2.5 - KITCHEN 2 UNIT 3-2.5 - KITCHEN 1 � wo8(D
1/4" = 1'-0" 1/4" = 1'-0"
• r� U 0000
W O w
O o
M
3-2.5 INTERIOR UNIT ELEVATIONS x O
v J Qtl
es pbotl Asso
6�9� caeN\
NEW CHROME SHOWER ROD NEW VANITY LIGHT FIXTURE
NEW CHROME TOWEL BAR NEW FRAMELESS, MIRRORED �''7diry9
REPLACE ALL WALL TILE IN MEDICINE CABINETS.
SHOWER. REFINISH EXISTING REPLACE ALL WALL TILE IN M
TUB WHERE REQ'D. SHOWER. REFINISH EXISTING
SEE FINISH SCHEDULES FOR TUB WHERE REQ'D.
Inr
TUB AND SHOWER GRAB BAR ° 7
LOCATION SEE FINISH SCHEDULES FOR f
� Z
TUB AND SHOWER GRAB BAR r<F
HEW CHROME TOILET PAPER _
LOCATION
ER
NEW PORCELAIN TOILET,
WHITE J
z
6 UNIT 3-2.4 (TYPE A) - BATHROOM 4 5UNIT 3-2.4 (TYPE A) - BATHROOM 3 UNIT 3-2.4 (TYPE A) - BATHROOM 2 UNIT 3-2.4 (TYPE A) - BATHROOM 1 D O_
1/411=11-011 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"
Q
I
PROVIDE 6" TRIM BOARD TO Lu
COVER GAP BETWEEN TOP w J
PROVIDE 6" TRIM BOARD TO OF CABINET AND CEILING w
COVER GAP BETWEEN TOP SIDE-BY-SIDE M
OF CABINET AND CEILING REFRIDGERATOR/FREEZER O O
NEW STAINLESS STEEL W/ WATER & ICE DISPENSER
DROP-IN SINGLE -BOWL SINK @ ALL TYPE'A' UNITS. 0
FILLER W/ SINGLE FAUCET HOLE MICROWAVE TO BE
6" 2' - 0" 2' 6" 2' - 6" ORNE MOUNTED UNDER 34" 1' -L21-611L112 0
COUNTER TOP @ ALL TYPE 'A' in ' U z
D
/A
/AIll
Ill
11rv7o, i� "vm"' w •• •,.
COUNTER TOPS DROP-IN RANGE W/ FRONT
CONTROLS & HOOD ABOVE
/
/
/
v
/ �
o
�/ /
Q LU
I
30" MIN. CLEAR WORKSPACE ALL TYPE W UNITS.
V
/
,'
e
LO
FL
REQ'D IN TYPE'A' UNITS.
1
PROVIDE REMOVABLE BLIND CORNER CABINET
CABINET FACE & EXTEND
" _ w �a M
FINISH FLOOR TO FACE OF PROVIDE SINK DRAIN ON
oC �jC�� WALL. PAINT WALL BEHIND LEFT-HAND SIDE AT KITCHEN
F/T\�F\ I� CABINET. SINK @ALL TYPE UNITS.F7 Lo LLQ 0
PROVIDE REMOVABLE RECESS GARBAGE DISPOSAL U m m
CABINET FACE SINK AIR SWITCH INTO
6" 2' - 0" 2' -A 2' - 6' CABINET & EXTEND FINISH COUNTERTREACH RANOGES @ AL P WITHINLTD PE
REMOVABL REMOVABLE FLOOR TO FACE OF WALL
BEYOND. PAINT WALL A UNITS. 1 9-01 6
BEHIND.
SHEET NO.
UNIT 3-2.4 (TYPE A) - KITCHEN 2 UNIT 3-2.4 (TYPE A) - KITCHEN 1 A3-804
2 1/4" = 1'-0" �� 1/4" = 1'-0"
3-2.4 (TYPE A) INTERIOR UNIT ELEVATIONS
REPLACE ALL WALL TILE IN
SHOWER. REFINISH EXISTING pF C of
TUB WHERE REQ'D. �F �9
REPLACE ALL WALL TILE IN 90
SHOWER. REFINISH EXISTING NEW VANITY LIGHT FIXTURE ERIC C
TUB WHERE REQ'D.
NEW FRAMELESS, MIRRORED - 'E
MEDICINE CABINETS. ° NEW FRAMELESS, MIRRORED 4 174
NEW CHROME TOWEL BAR MEDICINE CABINETS.I:]- NEW
l V�
PLASTIC LAMINATED BAR CHROME HAND TOWEL 0 A
COUNTERTOPS
NEW PORCELAIN TOILET, 0 _
NEW BASE CABINETS W/
WHITE HOLDER NEW CHROME TOILET PAPER 0� e o
CABINET PULLS
i� NEW CHROME TOILET PAPER
NEW PORCELAIN TOILET, HOLDER
oQ
WHITE 3' - 0" ' oz
4'_6"7 71
�v
w�
�o
,x
UNIT 3-2.3 - BATHROOM ELEVATION 3 UNIT 3-2.3 - BATHROOM ELEVATION 2 UNIT 3-2.3 - BATHROOM ELEVATION 1 aI
1/4" = 1'-0" 1/4" = 1'-0" �1/4" = 1'-0" V I
Lu
IrLu
FILLER 2' - 6" 2' - 6" 2' - 9" 3' - 0" FILLER
1' - 6" 2' - 0" 2' - 6" 2' - 0" PROVIDE 6" TRIM BOARD TO z0 U
COVER GAP BETWEEN TOP
NEW UPPER CABINETS W/ OF CABINET AND CEILING NEW BLACK OVER -RANGE a Lu
CABINET PULLS MICROWAVE Y I-
NEW STAINLESS STEEL > o NEW UPPER CABINETS W/ o NEW BLACK TOP -FREEZER U) o
DROP-IN SINGLE -BOWL SINK CABINET PULLS o REFRIDGERATOR p a_
W/ SINGLE FAUCET HOLE / / 0 TILE BACKSPLASH AT
KITCHEN
PLASTIC LAMINATED oN
COUNTERTOPS L7 PLASTIC LAMINATED L
COUNTER TOPS Q No
NEW BASE CABINETS W/ o
RANGNEW BASE CABINETS W/ CABINET PULLS
CABINET PULLS \ j e j PLAN DATES
NEW BLACK DISHWASHER ° h BLACK ELECTRIC r 1
6"� 2' - 0" � 2' - 6" ' - 311 FILLER�� � 2'-6" 2- - 9" 3--l"
w
UNIT 3-2.3 - KITCHEN ELEVATION 2 R UNIT 3-2.3 - KITCHEN ELEVATION 1 00
zO�
-011
• rIU O6.0
V W O w o
O � M
3-2.3 INTERIOR UNIT ELEVATIONS x Lo o
4-j
v J Qtl
es pbotl Asso
6�9� caeN\
NEW VANITY LIGHT FIXTURE
e c
i
i
NEW MULTI -PIECE
FIBERGLASS TUB & SHOWER
SURROUND
NEW MULTI -PIECE
FIBERGLASS TUB & SHOWER
SURROUND
[JF--�*
WHITE z
MD O
W
7 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 4 6 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 3 5 UNIT 3-2.1 and 3-2.2 -BATHROOM ELEVATION 2 Q
4 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 1 ,
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" >
Lu
W J
Lu
Q Mo O
D 0
LU
NEW UPPER CABINETS W/ 2'-6" 2'-6" 1'-6" 3'-0" 3'-0" y 3'-0" y2'-0" y1'-6" �f w O
CABINET PULLS
niMni ❑i nnu n%/I=D onnin_I= SO FIT NEW UPPER CABINETS W/
MICROWAVE
V J
NEW FRAMELESS, MIRRORED
MEDICINE CABINETS
`
i
i
i
U
9 DS.o
Lu
(D z
NEW CHROME SHOWER ROD—
WHITE z
MD O
W
7 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 4 6 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 3 5 UNIT 3-2.1 and 3-2.2 -BATHROOM ELEVATION 2 Q
4 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 1 ,
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" >
Lu
W J
Lu
Q Mo O
D 0
LU
NEW UPPER CABINETS W/ 2'-6" 2'-6" 1'-6" 3'-0" 3'-0" y 3'-0" y2'-0" y1'-6" �f w O
CABINET PULLS
niMni ❑i nnu n%/I=D onnin_I= SO FIT NEW UPPER CABINETS W/
MICROWAVE
V J
NEW FRAMELESS, MIRRORED
MEDICINE CABINETS
`
CABINET PULLS
NEW STAINLESS STEEL
9 DS.o
Lu
(D z
NEW CHROME SHOWER ROD—
N
BAR CHROME HAND TOWEL
i
DROP-IN SINGLE BOWL' SINK—
tnu cinir_i rni ir�T uni �
III
U ^
vw,
"ITI
> Q co
Q
N = D
NEW CHROME TOWEL BAR
N
r n
WINES
PLASTIC LAMINATED
V
COUNTER TOPS
7
NEW MULTI -PIECE
NEW DROP-IN PORCELAIN
FIBERGLASS TUB & SHOWER
SINK BOWL, WHITE
h
Q
SURROUND
NEW PORCELAIN TOILET,
WHITE z
MD O
W
7 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 4 6 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 3 5 UNIT 3-2.1 and 3-2.2 -BATHROOM ELEVATION 2 Q
4 UNIT 3-2.1 and 3-2.2 - BATHROOM ELEVATION 1 ,
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" >
Lu
W J
Lu
Q Mo O
D 0
LU
NEW UPPER CABINETS W/ 2'-6" 2'-6" 1'-6" 3'-0" 3'-0" y 3'-0" y2'-0" y1'-6" �f w O
CABINET PULLS
niMni ❑i nnu n%/I=D onnin_I= SO FIT NEW UPPER CABINETS W/
MICROWAVE
V J
z
Q
`
CABINET PULLS
NEW STAINLESS STEEL
Lu
(D z
NEW BLACK TOP -FREEZER v
REFRIDGERATOR
N
o
i
DROP-IN SINGLE BOWL' SINK—
tnu cinir_i rni ir�T uni �
III
U ^
vw,
N
PLASTIC LAMINATED PLASTIC LAMINATED v"
COUNTER TOPS00 COUNTER TOPS
NEW BLACK ELECTRIC \ NEW BLACK DISHWASHER
RANGE L/JM7D NEW BASE CABINETS W/
NEW BASE CABINETS W/ CABINET PULLS
CABINET PULLS
��1'_6"
���� 19-016
SHEET NO.
UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 3 UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 1
31/4" = 1'-0=1'-°" A3-805
3-2.1 and 3-2.2 INTERIOR UNIT ELEVATIONS
V J
z
Q
Lu
(D z
o
N
<
0 �_
n
U ^
vw,
"ITI
> Q co
Q
N = D
WINES
���� 19-016
SHEET NO.
UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 3 UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 1
31/4" = 1'-0=1'-°" A3-805
3-2.1 and 3-2.2 INTERIOR UNIT ELEVATIONS
V J
z
Q
Lu
(D z
o
N
<
0 �_
n
U ^
vw,
"ITI
> Q co
Q
N = D
���� 19-016
SHEET NO.
UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 3 UNIT 3-2.1 and 3-2.2 - KITCHEN ELEVATION 1
31/4" = 1'-0=1'-°" A3-805
3-2.1 and 3-2.2 INTERIOR UNIT ELEVATIONS
NEW UPPER CABINETS W/
CABINET PULLS
NEW STAINLESS STEEL
DROP-IN SINGLE -BOWL SINK
W/ SINGLE FAUCET HOLE
PLASTIC LAMINATED
COUNTER TOPS
NEW BLACK DISHWASHER
NEW BASE CABINETS W/
CABINET PULLS
' Iln'
5' - 0"
CD�olp
11111■III■III,,
I
i
p
W
LLI
b
�■■.
NEW BLACK TOP -FREEZER
�
h��pF
REFRIDGERATOR
o
c� ERIC C o
PLASTIC LAMINATED
O
E
COUNTERTOPS O
' A
U)
NEW VANITY LIGHT FIXTURE4
NEW UPPER CABINETS W/ �� _
L
174
NEW CHROME HAND TOWEL
NEW FRAMELESS, MIRRORED
_
NEW VANITY LIGHT FIXTURE
D A
NEW CHROME TOWEL BAR
BAR
MEDICINE CABINETS.
RANGE
0
e
0
PLAN DATES
NEW BASE CABINETS W/
NEW FRAMELESS, MIRRORED
i
NEW CHROME TOILET PAPER
NEW CHROME TOWEL BAR
PLASTIC LAMINATED
MEDICINE CABINETS.
U
HOLDER
COUNTERTOPS
N
i
o
NEW PORCELAIN TOILET,
i
o
ro
z
_
WHITE
NEW DROP-IN PORCELAIN
e e
W/ SINGLE FAUCET HOLE
NEW MULTI -PIECE
SINK BOWL, WHITE
e
i
NEW MULTI -PIECE
FIBERGLASS TUB & SHOWER
FIBERGLASS TUB & SHOWER
NEW BASE CABINETS W/
e
��_
NEW MULTI PIECE
FIBERGLASS TUB &SHOWER
oz
oz
SURROUND
SURROUND
CABINET PULLS
SURROUND
�o
00 N
,x
3 2 6 1 3
I
S
VI
—'
UNIT 3-1.2 — BATHROOM ELEVATION 4
UNIT 3-1.2 — BATHROOM ELEVATION 3
UNIT 3-1.2 —
BATHROOM ELEVATION 2
)UNIT 3-1.2 — BATHROOM ELEVATION 1
11.1 io
>
1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" U�%� 1/4" = 1'-0"
Lu
FILLER
FILLER
2'-0" 3'-0"
2'-0"
3'-0" 2'_3" 2'-6" 2'-3" 2'-0"
w
U)
NEW UPPER CABINETS W/
z0
w
O
CABINET PULLS
NEW UPPER CABINETS W/
CABINET PULLS
NEW STAINLESS STEEL
DROP-IN SINGLE -BOWL SINK
W/ SINGLE FAUCET HOLE
PLASTIC LAMINATED
COUNTER TOPS
NEW BLACK DISHWASHER
NEW BASE CABINETS W/
CABINET PULLS
' Iln'
5' - 0"
MICROWAVE
11111■III■III,,
I
i
p
W
LLI
b
�■■.
NEW BLACK TOP -FREEZER
�
REFRIDGERATOR
o
O O
PLASTIC LAMINATED
O
_
N
NN
COUNTERTOPS O
' A
U)
NEW BLACK OVER-RANGELu
5' - 0"
MICROWAVE
I
i
p
W
LLI
b
LLj
NEW BLACK TOP -FREEZER
�
REFRIDGERATOR
o
O O
PLASTIC LAMINATED
O
_
N
NN
COUNTERTOPS O
' A
U)
; U z
NEW UPPER CABINETS W/ �� _
L
r
0 o
NEW BLACK ELECTRIC
D
RANGE
0
e
0
PLAN DATES
NEW BASE CABINETS W/
°
i
CABINET PULLS
U
FILLER
3-0" � 2'-3" � 2'-6" �1'-3'� 3'-25/8" a
2'-0" 3' - 0" 2' - 0"
00
Q lUNIT 3-1.2 — KITCHEN ELEVATION 2 UNIT 3-1.2 — KITCHEN ELEVATION 1 z�(D
�V/ 1/4" = 1'_0.. , % 1/4.. = 1'_0.. w OJ N
�/ • r� U O 00 co
WO w
E -IO� o
M
3-1.2 INTERIOR UNIT ELEVATIONS x O
4-j
v J Qtl
es pbotl Asso
6�9� caeN\
NEW MULTI -PIECE
FIBERGLASS TUB & SHOWER
SURROUND
NEW PORCELAIN TOILET,
WHITE
NEW VANITY LIGHT FIXTURE
NEW VANITY LIGHT FIXTURE
NEW FRAMELESS, MIRRORED
MEDICINE CABINETS.
NEW DROP-IN PORCELAIN
SINK BOWL, WHITE
NEW BASE CABINETS W/
CABINET PULLS NEW MULTI -PIECE
FIBERGLASS TUB & SHOWER
NEW FRAMELESS, MIRRORED = '
MEDICINE CABINETS. V
NEW DROP-IN PORCELAIN v 7
SINK BOWL, WHITE v L
PLASTIC LAMINATED Q
COUNTERTOPS _
NEW MULTI -PIECE NEW BASE CABINETS W/ O e z
FIBERGLASS TUB & SHOWER CABINET PULLS O
SURROUND
-3' 2'-6" 1'-3' —
SURROUND
5' - 0"
a
I
i
UNIT 3-1.1 —BATHROOM ELEVATION 4 UNIT 3-1.1 —BATHROOM ELEVATION 3 UNIT 3-1.1 — BATHROOM ELEVATION 2 3 UNIT 3-1.1 — BATHROOM ELEVATION 1
W
LLI
b
LLj
1/4" = 1'-0" J 1/4" = 1'-0" J 1/4" = 1'-0" 1/4" = 1'-0"M
�
Q
O O
NEW STAINLESS STEEL
FILLER FILLER00
ORNE 3'-0" 2'-0" 3'-0" 2'-9" 2'-6" 3'-0" ORNE
Q LU
NEW UPPER CABINETS W/
ABINE CABINET PULLS ABINE
' A
U)
; U z
NEW UPPER CABINETS W/ �� _
NEW BLACK TOP -FREEZER
� ..:' —
0
0
i
h
REFRIDGERATOR
i
o
i
i
W/ SINGLE FAUCET HOLE
pp
i
NEW FRAMELESS, MIRRORED = '
MEDICINE CABINETS. V
NEW DROP-IN PORCELAIN v 7
SINK BOWL, WHITE v L
PLASTIC LAMINATED Q
COUNTERTOPS _
NEW MULTI -PIECE NEW BASE CABINETS W/ O e z
FIBERGLASS TUB & SHOWER CABINET PULLS O
SURROUND
-3' 2'-6" 1'-3' —
SURROUND
5' - 0"
a
I
i
UNIT 3-1.1 —BATHROOM ELEVATION 4 UNIT 3-1.1 —BATHROOM ELEVATION 3 UNIT 3-1.1 — BATHROOM ELEVATION 2 3 UNIT 3-1.1 — BATHROOM ELEVATION 1
W
LLI
b
LLj
1/4" = 1'-0" J 1/4" = 1'-0" J 1/4" = 1'-0" 1/4" = 1'-0"M
�
Q
O O
NEW STAINLESS STEEL
FILLER FILLER00
ORNE 3'-0" 2'-0" 3'-0" 2'-9" 2'-6" 3'-0" ORNE
Q LU
NEW UPPER CABINETS W/
ABINE CABINET PULLS ABINE
' A
U)
; U z
NEW UPPER CABINETS W/ �� _
NEW BLACK TOP -FREEZER
� ..:' —
CABINET PULLS
i
/
NEW BLACKOVcn-m/AlTI
MICROWAVE
�
�
i�
�
'J� LU
NEW STAINLESS STEEL
o
NEW BLACK TOP -FREEZER
j
Z
DROP-IN SINGLE -BOWL SINK
h
REFRIDGERATOR
i
o
i
W/ SINGLE FAUCET HOLE
pp
T
Ld
00 N
PLASTIC LAMINATED i
PLASTIC LAMINATED COUNTER TOPS W Q M
COUNTER TOPS
0 NEW BLACK ELECTRIC io 00 LLI (D
NEW BLACK DISHWASHER RANGE i i o = 0
o e �n
NEW BASE CABINETS W/ NEW BASE CABINETS W/ � N � m
CABINET PULLS CABINET PULLS
2'-3" 3'-0" 2'-0"
3'-0" 2'-9" 2'-6" 1'-6" 3'-75/8" -
016
�UNIT 3-1.1 — KITCHEN ELEVATION 2 UNIT 3-1.1 — KITCHEN ELEVATION 1 SHEET NO.
A3-806
3-1.1 INTERIOR UNIT ELEVATIONS /I\\—
a
M
M
M
0
N
O
N
r
N
V
24
iA
O
O
N
O
N
N
T
GENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
A. ROOF 30 PSF (35 PSF GROUND)
B. TYPICAL FLOOR 40 PSF (RESIDENTIAL)
100 PSF COMMON AREAS AND EXIT FACILITIES
C. WIND
3 SECOND GUST 115 MPH (ULT)
EXPOSURE B
E. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
F. CODE USED IN DESIGN: 2012 IBC.
2. FOUNDATIONS
A. MAXIMUM SOIL DESIGN PRESSURE 3000 PSF.
MINIMUM SOIL DESIGN PRESSURE 1000 PSF.
B. CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS IN SOILS REPORT NO.25195383
BY TERRACON DATED JANUARY 22, 2020.
C. ALL FOOTING BEARING ELEVATIONS SHOW AR ASUMED. EXACT BEARING ELEVATIONS
SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY CONTRACTOR WITH
APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS SHALL BE A MINIMUM
OF 36" BELOW EXTERIOR GRADE.
D. ALL FOOTINGS ARE TO PLACED ON FIRM, UNDISTURBED, NATURAL SOIL OR PROPERLY COMPACTED
BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL SHALL BE COMPACTED TO 95%
(MINIMUM) MODIFIED PROCTOR DENSITY PER ATSM D1557 UNLESS OTHERWISE RECOMMENDED IN T
SOILS REPORT. IF SOFT SPATS ARE ENCOUNTERED REMOVED SOIL AND RECOMPACT WITH THE
APPORVED FILL (RE: SOIL REPORT FOR DESCRIPTION OF BEARING SOIL.)
E. CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRID LINES UNLESS NOTED OTHERWISE
ON PLANS.
F. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TEST ON COMPACTED FILL
UNDER FOOTINGS AND INTERIOR SLABS -ON -GRADE.
G. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETE SO THAT CONDITIONS MAY BE
INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.
3. SLAB ON GRADE
A. THE PREPARATION OF THE SUBGRADE FOR THE SLAB ON GRADE SHALL BE IN STRICT
ACCORDANCE WITH THE PROJECT SOILS REPORT REFERENCED ABOVE. THE
CONTRACTOR SHALL DIRECT QUESTIONS REGARDING THE SUBGRADE PREPARATION
REQUIREMENTS TO THE GEOTECHNICAL ENGINEER.
4. CONCRETE
A. ALL CAST -IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT,
STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:
CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.
FOOTINGS 3000 psi STD --- ---
FOUNDATION WALLS 3000 psi STD --- ---
INTERIOR SLABS ON GRADE 3000 psi STD 0.50 ---
EXTERIOR CONCRETE (++) 4500 psi STD 0.45 6%-8%
++ MAXIMUM SLUMP SHALL NOT EXCEED 4".
B. IF CONCRETE SUPPLIER PROPOSES USE OF FLYASH HE SHALL PROVIDE OWNER WITH
LETTER INDICATING COST REDUCTION AT TIME OF BID. THE MODULUS OF ELASTICITY
OF ALL CONCRETE SHALL EXCEED WC1.5 33 F'C (OR 57,000 F'C NORMAL WEIGHT
CONCRETE).
C. CONTRACTOR SHALL SAWCUT OR TROWELCUT JOINTS IN SLABS ON GRADE. JOINTS
SHALL BE SPACED 15 FEET AND SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X 3/16"
WIDE WITHIN 12 HOURS AFTER POURING. CARRY ALL SLAB REINFORCEMENT THROUGH
JOINT.
D. SLABS, TOPPING, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A
HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF
SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE
SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE
ENGINEER.
E. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE
WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE
STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OF
CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.
5. REINFORCEMENT
A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM
A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE
DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60.
B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BE
LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER.
C. REINFORCEMENT PROTECTION UNLESS NOTED OTHERWISE:
1. CONCRETE POURED AGAINST EARTH 3"
2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH) 2"
3. COLUMNS AND BEAMS (TIE BARS) 1-1/2"
4. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4"
D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH
SECTIONS 7.5, 7.6 AND 7.7 OF ACI 318, LATEST EDITION.
E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR
AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL
BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND SHALL BE A
MINIMUM OF 80 BAR DIAMETERS FOR #7 AND #8 REINFORCEMENT UNLESS NOTED
OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
F. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS IN
CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY AT
EACH CORNER.
G. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED AS
FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS.
6. STRUCTURAL STEEL
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS
WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICH
SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B. LATEST
EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
MISCELLANEOUS EMBEDDED ITEMS SHALL BE A36 STEEL.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307 UNLESS NOTED
OTHERWISE.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. EXCEPT WHERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL
CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A
AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED
EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. WHEN
LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM
LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM
AND SPAN FOR NON -COMPOSITE MEMBERS.
E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS -D1.1.
F. MINIMUM WELDS TO BE PER AISC TABLE 32.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
G. FOR ALL BEAM/COLUMN OR BEAM/BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORT
SLOTS IN CONNECTION MEMBER ONLY (WT -SECTIONS, ANGLES OR SHEAR PLATES).
7. NON -SHRINK GROUT
A. NON -SHRINK GROUT SHALL BE PROVIDED:
1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS.
2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRY
SUPPORTS.
3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH
OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE.
8. WOOD
A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY HEM FIR GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 675 PSI
2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 850 PSI
5" THICK - 5" AND WIDER NO. 1 Fb = 1050 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITIVE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLEDIPPED OR BETTER).
C. TREATED SILL PLATE LUMBER MAY BE HEM -FIR, STRUCTURAL #1 GRADE.
D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X WOOD JOISTS.
SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS
IS REQUIRED.
E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304-9.1 UNLESS NOTED OTHERWISE.
HE F. LAMINATED BEAMS
1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH AT 12
PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL SIZES SHOWN
ARE NET.
2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCE
WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF
STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AITC.
3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUS
MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS.
MEMBERS SHALL BE DESIGNED WITH ZERO CAMBER WITH TOP SURFACE
CLEARLY STAMPED ON EACH MEMBER.
G. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE -TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE.
3. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED
WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
4. FOR ROOF USE 7/16" (24/16 SPAN RATING) EXPOSURE I SHEATHING NAILED
WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 7/16" EXPOSURE I PLYWOOD OR
OSB SHEATHING NAILED WITH 8d NAILS AT 3" ON CENTER ALONG PANEL
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
SHALL BE BLOCKED.
6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
H. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS AND
SHALL BE "BCI JOIST" AS MANUFACTURED BY BOISE CORPORATION.
ALTERNATES SHALL BE REVIEWED BY THE ENGINEER. TO BE CONSIDERED,
ALTERNATES SHALL HAVE A LOAD CAPACITY IN BENDING, SHEAR AND DEFLECTION
EQUAL TO OR GREATER THAN THE SIZE SHOWN ON THE DRAWINGS. WEB BLOCKING
AND BRIDGING TO BE AS REQUIRED BY THE JOIST MANUFACTURER.
I. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS
CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI.
BUILT UP MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS
RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR
5 1/4" WIDE MEMBERS.
J. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO FULFILL STRESS
REQUIREMENTS AND/OR LOADS NOTED ON DRAWINGS. SHOP DRAWINGS SHALL
INCLUDE CALCULATIONS AND BEAR THE STAMP OF A REGISTERED ENGINEER. PROVIDE
BRIDGING AND BLOCKING PER MANUFACTURER'S RECOMMENDATIONS UNLESS
OTHERWISE NOTED. PROVIDE CONSTRUCTION BRACING AS REQUIRED ERECTION NOTE:
CENTER WALL STUDS UNDER CENTER OF TRUSS LOCATIONS.
9. NON-STRUCTURAL ELEMENTS
A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
OTHER STRUCTURAL MOVEMENTS.
B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED UNLESS NOTED OTHERWISE.
10. MASONRY
A. ALL MASONRY CONSTRUCTION REQUIRES SPECIAL INSPECTIONS PER CHAPTER 17 OF
THE INTERNATIONAL BUILDING CODE.
B. CONCRETE BLOCK UNITS SHALL CONFORM TO ASTM C90, GRADE N. BRICK SHALL
FULFILL ASTM C62, C216 OR C652. MORTAR SHALL BE ASTM C270 TYPE S OR M.
C. MASONRY SHALL CONSIST OF CONCRETE BLOCK WITH A MINIMUM COMPRESSIVE
STRENGTH OF F'm OF 1500 PSI BASED ON NET AREA.
D. WALLS SHALL BE REINFORCED HORIZONTALLY AT 16" ON CENTER WITH 9 GAGE
MINIMUM LADDER -TYPE REINFORCEMENT MEETING ASTM A82 MASONRY WALL
REINFORCEMENT. HORIZONTAL REINFORCING SHALL BE CONTINUOUS AROUND
CORNERS.
E. UNLESS NOTED OTHERWISE, MASONRY WALLS SHALL ALSO BE REINFORCED WITH
ONE #5 VERTICALLY AT WALL ENDS, CORNERS, EACH SIDE OF DOOR OR WINDOW
OPENINGS AND AT NOT OVER 4'-0" FEET ON CENTER TYPICALLY. REINFORCEMENT
SHALL BE FULLY GROUTED IN PLACE. GROUT SHALL DEVELOP 3000 PSI IN 28 DAYS
AND MEET ASTM C476.
F. ALL CMU WALLS REQUIRE A MINIMUM OF 2-#5 IN BOND BEAM ABOVE ALL DOORS AND
WINDOWS, AT FLOOR AND ROOF LINES, AND TOP OF PARAPETS UNLESS OTHERWISE
NOTED.
G. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION JOINT LOCATIONS.
H. FILL ALL VOIDS AND BLOCK CELLS SOLIDLY WITH ASTM C476 GROUT FOR A DISTANCE
OF 24" BENEATH AND A MINIMUM OF 16" EACH SIDE OF ALL BEAM REACTIONS OR
OTHER CONCENTRATED LOADS UNLESS NOTED OTHERWISE.
I. CMU SHALL BE FULLY GROUTED BELOW GRADE.
J. PROVIDE A THICKENED CONCRETE SLAB UNDER ALL MASONRY PARTITION WALLS. SEE
ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF WALLS AND FOR
OPENINGS, ALL OF WHICH REQUIRE LINTELS. SEE LOOSE LINTEL SCHEDULE FOR
FRAMING OVER NON-BEARING OPENINGS IF NOT SHOWN ON STRUCTURAL DRAWINGS.
SEE MECHANICAL DRAWINGS FOR THOSE OPENINGS WHICH REQUIRE LINTELS.
K. ALL MULTIPLE WYTHE MASONRY WALLS SHALL BE GROUTED SOLID BETWEEN EACH
WYTHE WITH ASTM C476 GROUT.
L. WHERE MASONRY LINTELS CROSS EXPANSION CONTROL JOINTS IN MASONRY, INSTALL
LINTELS SO THAT THE LINTEL MAY SLIDE ON ONE END.
M. PROVIDE MASONRY TIES WHERE MASONRY ABUTS CONCRETE.
11. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND
ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND
REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY.
C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER
ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS
AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON
ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR
SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF
HIS ITEMS.
D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL,
MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDED
ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLED
BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36.
E. PROVIDE ASPHALTIC MASTIC -COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH.
F. SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL
STRUCTURAL STEEL, WOOD TRUSSES.
THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TO WRITTEN REVIEW OF
SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE CONTRACTOR.
G. WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
H. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR
WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE.
I. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD AND
ARCHITECTURAL DRAWINGS.
J. PRE -MANUFACTURED STAIRS, HANDRAILS, AND GUARDRAILS NOTED ON PLAN SHALL
HAVE ALL ENGINEERING, DESIGN AND DETAILING PROVIDED BY STAIR DESIGNER AND
SHALL BE SUBMITTED FOR ARCHITECTS REVIEW BEARING THE SEAL OF A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO. STAIRS SHALL
BE DESIGNED TO SUPPORT A LIVE LOAD OF 100 PSF. SEE ARCHITECTURAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS AND CRITERIA.
(E) 2X1(
JOISTS
(E) STE��
SECTION 3
314" = 1'-0"
SECTION 4
3/4" = 1'-0"
I I I
I I
I I
I I
(E) BEARING WALL
TO REMOVE I I
I I
I I
I I
I v
SECTION 5
3/4" = 1'-0"
(E) BEARING WALL
(E) FLOOR JOIST WITH
U28 HANGER (SHORE AS
REQUIRED)
NEW STEEL BEAM
BLOCK WEB SOLID
Y
L
i
L
c
3/16" MAX X T/4 DEEP _
3/4" MIN. SAW CUT
NOTE: RE: PLANS AND
GENERAL NOTES FOR
SPACING OF CONTROL
JOINTS
ss-
NOTE:
RE: SOILS REPORT FOR OVER
EXCAVATION REQUIRED BELOW
INTERIOR SLAB -ON -GRADE.
5/8"0 X 18" SMOOTH
ROD AT 12". GREASE
ONE END - TYPICAL
SAW CUT
N
H
DOWELED
SLAB JOINT DETAIL 1
3/4" = 1'-0"
#5 VERTICAL (TYP.)
DEVELOPMENT
LAP LENGTH
ea
a °
•d
= HORIZONTAI
REINFORCEI
w (TYP.)
J
#5 VERTICAL (TYP.)
ol DEVELOPMENT
10
LAP LENGTH
#5 VERTICAL (TYP.) OR
MATCH VERTICAL WALL
REINFORCING
LAP LENGTH
it =
0
90 HOOK
`w
=
1 C7
O
0
a
�
C7
W
U
O
W
L
a
Z
O
U
°
a
W
>
a
a
°
CORNER INTERSECTION
CORNER DETAIL 2
314" = 1'-0"
RE: PLAN
PROVIDE STANDARD
HOOK
e
a' d 1I -
e e .
de•
TYPICAL FOOTING
REINFORCEMENT
No ' II
LAP LENGTH
RE: GENERAL NOTES
ih
TYPICAL STEPPED
FOOTING DETAIL
3/4" = 1'-0"
BARS TO MATCH
TYPICAL FOOTING
REINFORCEMENT
W d
U
M
W
z*�
u
M
(DZ
U)
Z
O
U
rw
V
0
z
'Q
V )
w
O
M Z
O J
c
w
Lu OZ
>v w
Q rwn 0
�V 1
0 M
L.L V
Z
Q
L0 w
S"') 2 -
W
19-016
SHEET NO.
S3-100
0
O
0
U
O
Z
O
U
w
U
cma
o
a
Z
CD
0
O
0001
N
N
N
N
0
O
O
PLAN DATES
'*..0
U
'..j
F-=1
O 0
D
Ix9
O
[
T
L
DO04
0000N
W
O W o
0O M
0
F--�1
x
O
Lo C9
U
Lo
�
VJ
r
x
w
CAA
0
M
(DZ
U)
Z
O
U
rw
V
0
z
'Q
V )
w
O
M Z
O J
c
w
Lu OZ
>v w
Q rwn 0
�V 1
0 M
L.L V
Z
Q
L0 w
S"') 2 -
W
19-016
SHEET NO.
S3-100
VAF
24
Lo
0
CD
O
N
O
N
N
T
SECTION 1
3/4" = 1'-0"
IES
LEVEL 2 FRAMING PLAN
1/811=11-01,
11"rr vwrn 1 -uI-uw k i i 1 .)
LtVtL "I/I-UUNUA I IUIN FLAIN
I JQ'. - 1,-n,.
= U k•.
N W
Z
0
0
ui
U
O
0
Z O
O w U
a 2
U o U)
a Z
w 0 O
OIL) U
04 04
IN IN
w �t to
H N N
o O O
PLAN DATES
Lo2r.n.-
00
9CD
Q O T
00 00
N
W O
o0
M
�O
L�
O�
CAA
061 5/2uz0
M
(DZ
J
m
w
M
M
O
z
�
c
Q
�
U)
w0
>
U
aw
0
Q
ooh
C/)
w
�<
Q�
=
o
CU
�
3:
19-016
SHEET NO.
S3-101
24
iA
0
0
N
0
N
rn
N
T
LEVEL 2 DEMO PLAN
1/811=11-01,
\ (E) STOOP AND STAIRS
LEVEL 1 DEMO PLAN TO REMOVE (TYP.)
1/81, =1'-0"
= U k•.
N W
Z
0
0
C6
U
O
Q
Z O
O w U
a 2
U o U)
a Z
C/) Q O
OIL) U
04 04
W co
0 o o
PLAN DATES
Lo2r.n.-
00
9CD
0 O T
00 00
N
oU W O
Q M
�O
L
G` r
CAA
M
0
Z
J
m
W
co
O
U)
CIDZ
CY0
�U
Qw
0
Q
�C�
p
W
p
ooh
w
<
�
Q
Lo=
p
19-016
SHEET NO.
S3 -101D
HVAC, PLUMBING, ELECTRICAL, AND GENERAL CONTRACTOR COORDINATION SCHEDULE
CATEGORY
DESCRIPTION OF WORK
FURNISHED BY
MOUNTED BY
WIRED BY
NOTES
LOCATING
EXISTING UTILITIES
EXTERIOR
G.C.
- - -HW UF-
HOT WATER, UNDER FLOOR
- - HW(E)
INTERIOR
P.C. AND E.C.
<1
1 TO <1-1/2
EACH TRADE RESPONSIBLE FOR LOCATING THEIR RESPECTIVE SYSTEMS.
TEMPORARY
UTILITIES
TEMPORARY HEAT
G.C.
SERVICE HOT WATER (WITH HEAT TRACE)
0.27 MAX
-
TEMPORARY ELECTRICAL SERVICE
E.C.
E.C.
E.C.
R(E)D
WATER AND TOILET AND FACILITIES
G.C.
0.27 MAX
-
1"
CONCRETE
M/E EQUIPMENT PADS, HOUSEKEEPING PADS,
CONCRETE SAWING, PATCHING, CORE DRILLING, AND
REPAIR.
G.C.
EXIST. SANITARY SEWER ABOVE FLOOR
1"
SERVICE HOT WATER (FIRST 8' OF NON -CIRCULATION
EXCAVATION
EXCAVATION, BACKFILL, AND CONCRETE OR ASPHALT
PAVING FOR UTILITIES OR OTHER M/E EQUIPMENT.
G.C.
0.5"
0.5"
0.5"
HVAC ROOF TOP
EQUIPMENT,
FIELD BUILT ROOF
CURBS/PLATFORMS,
AND DUCT CURBS.
FOR ALL ROOF
CONSTRUCTION
EXCEPT METAL
ROOFS.
STRUCTURAL FRAMING FOR SUPPORT.
G.C.
SAND/OIL INTERCEPTOR LINE ABOVE FLOOR
S/0
G.C. ALSO TO PROVIDE FRAMING FOR PENETRATIONS.
FIELD BUILT EQUIPMENT PLATFORMS AND DUCT CURBS,
TOP MINIMUM 9" ABOVE FINISHED ROOF.
G.C.
---------S/0(E)---
EXISTING SAND/OIL INTERCEPTOR LINE UNDER FLOOR
G.C. TO CONSTRUCT PLATFORM/CURB FROM 2X10'S AS REQ'D AND CAP
WITH 3/4" PLYWOOD AND 40# COATED FELT.
FLASHING OVER THE TOP OF PLATFORMS AND
DUCT CURBS.
H.C.
250
4.5"
H.C. TO PROVIDE 26 GA. G.S. METAL TOP EXTENDING 3' DOWN SIDES.
ALL JOINTS SOLDERED WATERTIGHT.
ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM
G.C.
-•-•-•-•-•-•- OD -•-•-
5"
MECHANICAL SYSTEM PIPING 251-350
WAC ROOF TOP
EQUIPMENT,
FIELD BUILT ROOF
CURBS/PLATFORMS,
AND DUCT CURBS.
METAL ROOFS ONLY.
STRUCTURAL FRAMING FOR SUPPORT.
G.C.
4.0"
4.5"
G.C. ALSO TO PROVIDE FRAMING FOR PENETRATIONS.
EQUIPMENT CURBS, PLATFORMS, AND DUCT CURBS.
G.C.
MECHANICAL SYSTEM PIPING 201-250
0.27-0.30
G.C. TO OBTAIN ROOF CURBS FROM BUILDING MANUFACTURER ON NEW
CONSTRUCTION PROJECTS.
FLASHING OVER THE TOP OF PLATFORMS AND
DUCT CURBS.
H.C.
2.5"
3"
H.C. TO PROVIDE 26 GA. G.S. METAL TOP EXTENDING 3' DOWN SIDES.
ALL JOINTS SOLDERED WATERTIGHT.
ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM
G.C.
0.25-0.29
125
1.5"
MECH/ELEC
EQUIPMENT AND
FIXTURE MOUNTING
STRUCTURAL FRAMING FOR SUPPORT.
G.C.
PVC COMBUSTION AIR
2.0"
MECHANICAL SYSTEM PIPING 105-140
HANGERS, MOUNTING HARDWARE, ANCHORS,
PIPING STANDS, AND EQUIPMENT LEGS.
H.C. P.C. E.C.
H.C. P.C. E.C.
1.0"
EACH TRADE RESPONSIBLE FOR MOUNTING THEIR RESPECTIVE EQUIPMENT.
ROOFING AND
ROOF
PENETRATIONS
PIPE AND ROUND DUCT/VENT ROOFJACKS.
H.C. P.C. E.C.
H.C. P.C. E.C.
0.21-0.27
G.C. TO PROVIDE ROOFJACKS AND FLASHING ON METAL ROOF SYSTEMS.
PITCH PANS FOR EQUIPMENT LEGS OR PIPE STANDS.
H.C. P.C. E.C.
H.C. P.C. E.C.
1.0"
EACH TRADE RESPONSIBLE FOR PITCH PANS REQ'D FOR THEIR EQUIPMENT.
DRAIN, OVERFLOW SCUPPERS, AND GUTTERS.
G.C.
0.20-0.26
75
0.5"
ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM
G.C.
1.0"
1.5"
PATCH/REPAIR
PATCHING AND REPAIRING OF EXISTING CONSTRUCTION.
G.C.
0.5"
0.5"
0.5"
PAINTING
EQUIPMENT, DUCTS, PIPES, LOUVERS, AND ETC.
G.C.
FOOTNOTES:
NOT IN CAVITIES
(A) FOR PIPING SMALLER THAN 11/2 INCH (38 MM) AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH (25 MM) SHALL
ACCESS DOORS
FOR M/E EQUIPMENT REQUIRING ACCESS.
H.C. P.C. EC.
G.C.
EACH TRADE TO FURNISH ACCESS DOORS AS REQ'D FOR THEIR EQUIP.
FIRE RATED CHASES
FOR GREASE DUCTS, FLUES, DUCTS, AND ETC.
G.C.
2. FACTORY -INSTALLED PIPING WITHIN ROOM FAN -COILS AND UNIT VENTILATORS TESTED AND RATED ACCORDING TO AHRI 440 (EXCEPT THAT THE SAMPLING AND VARIATION
ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA
PROVISIONS OF SECTION 6.5 SHALL NOT APPLY) AND 840, RESPECTIVELY.
ELECTRICAL
CONTROL TRANSFORMERS FOR HVAC EQUIPMENT
H.C.
E.C.
E.C.
5. STRAINERS, CONTROL VALVES, AND BALANCING VALVES ASSOCIATED WITH PIPING 1 INCH (25 MM) OR LESS IN DIAMETER.
HVAC CONTROL WIRING 48 VOLTS AND LESS.
H.C.
H.C.
HVAC CONTROL WIRING GREATER THAN 48 VOLTS.
E.C.
E.C.
INCLUDING
HVAC EQUIP. INTERLOCK WIRING HIGH AND LOW VOLTAGE.
E.C.
WELL AS GROUP R-2, R-3 AND R-4 BUILDINGS THREE STORIES OR LESS IN HEIGHT
E.C.
ABOVE GRADE PLANE.
CONDUIT FOR ALL WIRING.
E.C.
EC.
DISCONNECT SWITCHES.
E.C.
E.C.
E.C.
MOTOR STARTERS TO INCLUDE THERMAL OVERLOADS.
H.C. AND P.C.
EC.
E.C.
EACH TRADE TO FURNISH STARTERS AS REQ'D FOR THEIR EQUIP.
DUCT MOUNTED
SMOKE DETECTORS
INTERFACED WITH BUILDING FIRE ALARM SYSTEM.
F.A.C. OR E.C.
H.C.
FAC. OR E.C.
H.C. TO PROVIDE ACTUAL DUCT SIZE MEASUREMENTS.
IN BUILDING W/O FIRE ALARM/DETECTION SYSTEM.
H.C.
H.C.
E.C.
INTERLOCKS W/HVAC SYSTEM FANS.
E.C.
ABBREVIATIONS: E.C.-ELECTRICAL CONTRACTOR, F.A.C.-FIRE ALARM CONTRACTOR, G.C.-GENERAL CONTRACTOR, H.C.-HVAC CONTRACTOR, M/E-MECHANICAL/ELECTRICAL, P.C.-PLUMBING CONTRACTOR
COMMERCIAL PIPING INSULATION SCHEDULE 2018 IECC
COLD WATER
- - ------ CW UF-
THICKNESS OF INSULATION (INCHES) (A)
- CW(E)
EXISTING COLD WATER
INSULATION CONDUCTIVITY
NOMINAL PIPE OR TUBE SIZE (INCHES)
- - -HW
SERVICE
FLUID OPERATING TEMPERATURE RANGE
- - -HW UF-
HOT WATER, UNDER FLOOR
- - HW(E)
CONDUCTIVITY (B)
* r
MEAN RATING
TEMPERATURE,
<1
1 TO <1-1/2
1-1/2 TO <4
4 TO <8
TEMPERED WATER, TEMP NOTED, BELOW FLOOR
-<8
SERVICE HOT WATER (WITH HEAT TRACE)
0.27 MAX
-
1"
1"
1'
1"
R(E)D
1"
SERVICE HOT WATER (RE-CIRULATING)
0.27 MAX
-
1"
1"
1'
1"
EXIST. SANITARY SEWER ABOVE FLOOR
1"
SERVICE HOT WATER (FIRST 8' OF NON -CIRCULATION
0.27 MAX
-
0.5"
0.5"
0.5"
0.5"
---------GI(E)----
0.5"
SYSTEMS AT EQUIPMENT WITHOUT HEAT TRAPS)
SAND/OIL INTERCEPTOR LINE ABOVE FLOOR
S/0
SAND/OIL INTERCEPTOR LINE UNDER FLOOR
---------S/0(E)---
EXISTING SAND/OIL INTERCEPTOR LINE ABOVE FLOOR
---------S/0(E)---
EXISTING SAND/OIL INTERCEPTOR LINE UNDER FLOOR
-•-•-•-•-•-•- RD -•-•-
MECHANICAL SYSTEM PIPING >3517F
0.32-0.34
250
4.5"
5"
5"
5"
-•-•-•-•-•-•- OD -•-•-
5"
MECHANICAL SYSTEM PIPING 251-350
0.29-0.32
200
3"
4.0"
4.5"
4.5"
SEWER VENT ABOVE FLOOR
4.5"
MECHANICAL SYSTEM PIPING 201-250
0.27-0.30
150
2.5"
2.5"
2.5"
3"
®D UF®
3 -
MECHANICAL SYSTEM PIPING 141-200
0.25-0.29
125
1.5"
1.5"
2.0'
2.0"
PVC COMBUSTION AIR
2.0"
MECHANICAL SYSTEM PIPING 105-140
0.21-0.27
100
1.0"
1.0"
1.5'
1.5'
G(E)
1.5'
MECHANICAL SYSTEM PIPING 40-60
0.21-0.27
75
0.5"
0.5"
1.0'
1.0"
OXYGEN
1.0"
MECHANICAL SYSTEM PIPING <40
0.20-0.26
75
0.5"
1.0"
1.0'
1.0"
1.5"
ROOF DRAIN (HORIZONTAL OR UNHEATED AREAS) (C)
0.27
-
0.5"
0.5"
0.5"
0.5
0.5"
FOOTNOTES:
NOT IN CAVITIES
(A) FOR PIPING SMALLER THAN 11/2 INCH (38 MM) AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES, REDUCTION OF THESE THICKNESSES BY 1 INCH (25 MM) SHALL
BE PERMITTED (BEFORE THICKNESS ADJUSTMENT REQUIRED IN FOOTNOTE B) BUT NOT TO A THICKNESS LESS THAN 1 INCH (25 MM).
SOLID WALL
(B) FOR INSULATION OUTSIDE THE STATED CONDUCTIVITY RANGE, THE MINIMUM THICKNESS (T) SHALL BE DETERMINED USING THE EQUATION IN THE 2015 IECC SECTION C403.2.1.
(C) IECC DOES NOT REQUIRE ROOF DRAINS TO BE INSULATED. INSULATION IS REQUIRED AS GOOD DESIGN PRACTICE.
EXCEPTIONS:
AIR PLENUM
1. FACTORY -INSTALLED PIPING WITHIN HVAC EQUIPMENT TESTED AND RATED IN ACCORDANCE WITH A TEST PROCEDURE REFERENCED BY THIS CODE.
F493, SOLVENT CEMENT MUST BE YELLOW, LIMITED TO 1/2" THROUGH 2" PIPE SIZES,
2. FACTORY -INSTALLED PIPING WITHIN ROOM FAN -COILS AND UNIT VENTILATORS TESTED AND RATED ACCORDING TO AHRI 440 (EXCEPT THAT THE SAMPLING AND VARIATION
ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA
PROVISIONS OF SECTION 6.5 SHALL NOT APPLY) AND 840, RESPECTIVELY.
3. PIPING THAT CONVEYS FLUIDS THAT HAVE A DESIGN OPERATING TEMPERATURE RANGE BETWEEN 60•F (15'C) AND 105'F (41'C).
4. PIPING THAT CONVEYS FLUIDS THAT HAVE NOT BEEN HEATED OR COOLED THROUGH THE USE OF FOSSIL FUELS OR ELECTRIC POWER.
5. STRAINERS, CONTROL VALVES, AND BALANCING VALVES ASSOCIATED WITH PIPING 1 INCH (25 MM) OR LESS IN DIAMETER.
6. DIRECT BURIED PIPING THAT CONVEYS FLUIDS AT OR BELOW 60-F (15'C).
GENERAL NOTES:
- 2018 IECC SECTIONS C403.2.10, C403.2.1 AND C404.4. - INSULATION EXPOSED TO WEATHER SHALL BE JACKETED WITH .016" THICK
- 2018 IECC COMMERCIAL SECTION APPLIES TO ALL BUILDINGS THAT ARE NOT CONSIDERED ALUMINUM.
"RESIDENTIAL BUILDINGS". "RESIDENTIAL BUILDINGS" ARE DETACHED ONE- AND - INSULATION ON COLD PIPES SHALL HAVE A VAPOR BARRIER APPLIED
INCLUDING
TWO-FAMILY DWELLINGS AND MULTIPLE SINGLE-FAMILY DWELLINGS (TOWNHOUSES) AS ALL JOINTS AND TERMINATIONS.
WELL AS GROUP R-2, R-3 AND R-4 BUILDINGS THREE STORIES OR LESS IN HEIGHT
ABOVE GRADE PLANE.
I GENERAL PLUMBING PROVISIONS I
1. WORK INCLUDED.
PROVIDE COMPLETE AND OPERATING PLUMBING SYSTEMS. THE WORK ALSO INCLUDES THE
COMPLETION OF DETAILS NOT MENTIONED OR SHOWN WHICH ARE NECESSARY FOR THE
SUCCESSFUL OPERATION OF ALL SYSTEMS. SEE 'HVAC, PLUMBING, ELECTRICAL AND GENERAL
CONTRACTOR COORDINATION SCHEDULE' FOR DIVISION OF WORK.
2. PLUMBING DRAWINGS.
PLUMBING DRAWINGS ARE DIAGRAMMATIC AND ARE NOT TO BE SCALED FOR DIMENSIONS.
TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS
AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK. VERIFY SPACE
REQUIREMENTS, COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE
SPACE PROVIDED WITHOUT VIOLATION OF APPLICABLE CODES, STANDARDS, SPECIFICATION
REQUIREMENTS, OR EXTRA CHARGES TO THE OWNER.
3. VERIFICATION OF FIELD CONDITIONS.
BEFORE UNDERTAKING EACH PART OF THE WORK, CAREFULLY STUDY AND COMPARE THE
CONTRACT DOCUMENTS WITH FIELD MEASUREMENTS. PROMPTLY REPORT IN WRITING TO THE
MECHANICAL ENGINEER ANY CONFLICT, ERROR OR DISCREPANCY.
4. EQUIPMENT AND FIXTURES FURNISHED BY OTHERS.
COORDINATE EXACT REQUIREMENTS OF EQUIPMENT AND FIXTURES FURNISHED BY OTHERS
BEFORE PERFORMING ANY WORK.
5. PERMITS.
APPLY FOR AND PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS
DIVISION OF WORK.
6. CODES.
COMPLY WITH ALL APPLICABLE CODES AND UTILITY COMPANY REGULATIONS. IN CASE OF
CONFLICT WITH THE CONTRACT DOCUMENTS THE MOST STRINGENT SHALL GOVERN.
7. ACCESS DOORS.
FURNISH ACCESS DOORS TO PROVIDE ACCESS TO ALL FIRE DAMPERS, VALVES, BALANCING
DAMPERS, AND OTHER EQUIPMENT REQUIRING ACCESS. ACCESS DOORS FOR INSTALLATION
IN FIRE RATED CONSTRUCTION SHALL HAVE APPROPRIATE FIRE RATING.
8. SPECIFIED MANUFACTURERS AND ALTERNATES.
AN ACCEPTABLE MANUFACTURER'S NAME AND MODEL NUMBER OF A PRODUCT MAY BE GIVEN
FOR AN EXAMPLE. THIS IS THE EQUIPMENT CONTEMPLATED DURING THE DESIGN PROCESS
AND FORMS THE BASIS OF A STANDARD OF QUALITY. VERIFY THE MODEL NUMBER IS STILL
ACCURATE AND MEETS ALL THE REQUIREMENTS AS SHOWN ON THE DRAWINGS. IF THERE
IS A DISCREPANCY BETWEEN THE REQUIREMENTS OF THE DRAWINGS AND THE MODEL NUMBER,
THE REQUIREMENTS OF THE DRAWINGS SHALL GOVERN. APPROVED EQUALS SHALL BE
ALLOWED UNLESS OTHERWISE NOTED.
9. SUBMITTALS.
A. REQUIRED SUBMITTALS.
SUBMIT ELECTRONIC COPIES OF THE FOLLOWING INFORMATION FOR APPROVAL ORDER
NO MATERIALS OR BEGIN NO WORK UNTIL ALL SUBMITTALS ARE RETURNED APPROVED.
1.) ALL SCHEDULED FIXTURES AND EQUIPMENT.
2.) CONTROLS AND CONTROL DIAGRAMS.
3.) SHOP DRAWINGS REQUIRED TO BE SUBMITTED FOR APPROVAL
4.) OTHER INFORMATION SPECIFICALLY REQUIRED TO BE SUBMITTED FOR APPROVAL.
B. REVIEW TIME.
ALLOW 5 WORKING DAYS FOR REVIEW OF SUBMITTALS.
C. RESUBMISSION.
MAKE ALL REVISIONS REQUIRED AND RESUBMIT AS REQUIRED FOR INITIAL SUBMITTAL
10. WARRANTIES.
GUARANTEE ALL WORKMANSHIP, MATERIAL AND EQUIPMENT AND REPLACE ANY FOUND
DEFECTIVE WORK WITHOUT COST TO THE OWNER, FOR A PERIOD OF ONE YEAR AFTER
FINAL ACCEPTANCE.
11. OPERATION AND MAINTENANCE MANUALS.
SUBMIT 3 COPIES BOUND IN 8-1/2" X 11" THREE RING, LOOSE LEAF BINDERS.
12. MATERIALS.
ALL MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE SPECIFIED.
A ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA
REDUCTION OF LEAD IN DRINKING WATER ACT OF 2011.
13. INSTALLATION OF EQUIPMENT.
A GENERAL
B. SPACE PREFERENCE.
WHERE CONFLICTS OCCUR THE FOLLOWING PREFERENCE SCHEDULE SHALL BE USED:
1. RECESSED ELECTRICAL LIGHT FIXTURES.
2. DUCTWORK.
3. SPRINKLER PIPING.
4. SOIL, WASTE, VENT AND STORM PIPING.
5. LIQUID HEAT TRANSFER AND REFRIGERANT PIPING.
6. DOMESTIC WATER PIPING.
7. ELECTRICAL CONDUITS.
ITEMS /2 SWILL NOT HAVE PREFERENCE OVER ITEM #4 BELOW PLUMBING
FIXTURES, OR OVER ITEM #7 ABOVE OR BELOW ELECTRIC SWITCH GEAR AND PANELS.
NO PIPING CONVEYING FLUIDS SHALL BE INSTALLED DIRECTLY OVER ELECTRICAL
EQUIPMENT.
14. PIPE INSULATION.
SEE EITHER THE COMMERCIAL OR RESIDENTIAL PIPE INSULATION SCHEDULE FOR WHERE
PIPE INSULATION IS REQUIRED. OTHER INSULATION MAY BE REQUIRED IF R IS SPECIFICALLY
CALLED OUT ON THE PLANS.
I PLUMBING LEGEND I
SYMBOL DESCRIPTION
- ------- CW
COLD WATER
- - ------ CW UF-
COLD WATER, UNDER FLOOR
- CW(E)
EXISTING COLD WATER
- CW(E) OF
EXISTING COLD WATER, UNDER FLOOR
- - -HW
HOT WATER
- - -HW UF-
HOT WATER, UNDER FLOOR
- - HW(E)
EXISTING HOT WATER
- - HW(E) OF
EXISTING HOT WATER, UNDER FLOOR
- - - 105'-
TEMPERED WATER, TEMPERATURE NOTED (FAHRENHEIT)
- - -105' UF-
TEMPERED WATER, TEMP NOTED, BELOW FLOOR
- - 105'(E)
EXISTING TEMPERED WATER, TEMP NOTED (FAHRENHEIT)
- - 105'(E) OF
EXISTING TEMPERED WATER, TEMP NOTED, UNDER FLOOR
-•-R In
HOT WATER CIRCULATION RETURN WITH FLOW ARROW
-•- UFS
HOT WATER CIRCULATION RETURN, UNDER FLOOR
R(E)D
EXISTING HOT WATER CIRC. RETURN WITH FLOW ARROW
- - - -00--R(E) OF
EXISTING HOT WATER CIRC. RETURN, UNDER FLOOR
SS-
SANITARY SEWER ABOVE FLOOR
-SS-
SANITARY SEWER UNDER FLOOR
SS(E)
EXIST. SANITARY SEWER ABOVE FLOOR
- -SS(E)
EXIST. SANITARY SEWER UNDER FLOOR
----------GI----
GREASE INTERCEPTOR LINE ABOVE FLOOR
GI
GREASE INTERCEPTOR UNE UNDER FLOOR
- - - - - - - --GI(E)- - - -
EXISTING GREASE INTERCEPTOR LINE ABOVE FLOOR
---------GI(E)----
EXISTING GREASE INTERCEPTOR UNE UNDER FLOOR
---------S/0----
SAND/OIL INTERCEPTOR LINE ABOVE FLOOR
S/0
SAND/OIL INTERCEPTOR LINE UNDER FLOOR
---------S/0(E)---
EXISTING SAND/OIL INTERCEPTOR LINE ABOVE FLOOR
---------S/0(E)---
EXISTING SAND/OIL INTERCEPTOR LINE UNDER FLOOR
-•-•-•-•-•-•- RD -•-•-
ROOF DRAIN ABOVE FLOOR
RD
ROOF DRAIN UNDER FLOOR
-- - - ---RD(E)-.- -
EXISTING ROOF DRAIN ABOVE FLOOR
------.-RD(E)�
EXISTING ROOF DRAIN UNDER FLOOR
-•-•-•-•-•-•- OD -•-•-
ROOF OVERFLOW DRAIN ABOVE FLOOR
OD
ROOF OVERFLOW DRAIN UNDER FLOOR
-------OD(E)-.- -
EXISTING ROOF OVERFLOW DRAIN ABOVE FLOOR
.......... --OD(E)---
EXISTING ROOF OVERFLOW DRAIN UNDER FLOOR
-V- -
SEWER VENT ABOVE FLOOR
- - - - -V UF--
SEWER VENT UNDER FLOOR
V(E)
EXISTING SEWER VENT ABOVE FLOOR
V(E) UF- -
EXISTING SEWER VENT UNDER FLOOR
-••-••-••-••-••-D-••-••-
EQUIPMENT DRAIN ABOVE FLOOR
®D UF®
EQUIPMENT DRAIN BELOW FLOOR
- - - - --D(E)..
EXISTING EQUIP. DRAIN ABOVE FLOOR
- - - - -D(E) UF-
EXISTING EQUIP. DRAIN BELOW FLOOR
- - -CV- -
PVC COMBUSTION VENT
--C/1 -
PVC COMBUSTION AIR
- -CV(E)
EXISTING PVC COMBUSTION VENT
- -CA(E)
EXISTING PVC COMBUSTION AIR
G
NATURAL GAS ABOVE FLOOR
G UF-
NATURAL GAS UNDER FLOOR
G(E)
EXISTING NAT. GAS ABOVE FLOOR
G(E) OF
EXISTING NAT. GAS UNDER FLOOR
A
COMPRESSED AIR
NO
NITROUS OXIDE
0
OXYGEN
VAC-
VACUUM
C
ELBOW DOWN
0
ELBOW UP
TEE DOWN
TEE UP
-ili-
UNION
HOSE BIBB
-►� GATE VALVE, NORMALLY OPEN
-D4- GATE VALVE, NORMALLY CLOSED
BALL VALVE, NORMALLY OPEN
BALL VALVE. NORMALLY CLOSED
n SOLENOID VALVE NORMALLY OPEN
ACCUSETTER VALVE FOR RECIRCULATING SYSTEMS
Nc c 3 -WAY MOTORIZED VALVE
No
--
CENTRIFUGAL PUMP
PIPE
GAS COCK
PROTECTION
LOG LIGHTER VALVE
®
AIR ADMITTANCE VALVE (STUDOR VENT)
SCH. 40 BLACK
GAS REGULATOR
c
LOCATION OF COLD WATER ROUGH -IN.
•
LOCATION OF HOT WATER ROUGH -IN.
CONNECTION TO EXIST. WORK, SEE CONNECTION
1 NOTE #1 FOR EXPLANATION IF APPLICABLE
XX- PLAN CODE FOR EQUIPMENT FURNISHED BY OTHERS.
PLUMBER TO PROVIDE ROUGH -IN AND FINAL
CONNECTION. REFER TO FIXTURES/EQUIPMENT
FURNISHED BY OTHERS SCHEDULE COORDINATE
WITH SUPPLIER TO DETERMINE EXACT REQUIREMENTS
BEFORE PERFORMING ANY WORK.
GAS PIPING SCHEDULE
SERVICE
PIPE
FITTINGS
PROTECTION
COVER
REMARKS
WROUGHT COPPER
SCH. 40 BLACK
150# MALLEABLE
APPROVED PROTECTIVE COATING EITHER
AT LEAST 12" OF
FUEL GAS PIPING.
BLACK IRON.
IRON WELDED.
FIELD OR FACTORY APPLIED.
EARTH COVER.
•
NATURAL GAS)
OUTSIDE BUILDING.
TYPE "K" SOFT
FLARED TYPE
0zr
two
Om
DRAWN COPPER.
O 0
O
� C7
4_j
COLD WATER AND
TYPE "K" COPPER
BURIED)*
POLYETHYLENE
POLYETHYLENE
PIPE SHALL HAVE THE WORD "GAS"
AT LEAST 18" OF
1/2"0 PIPE SHALL BE
WITHIN BUILDING.
(PE 2406)
(PE 2406)
MARKED ON IT AND A TRACER WIRE
EARTH COVER.
SDR 9. PIPE >1/2"0
WROUGHT COPPER
ASTM D 2513
ASTM D 2513, ASTM
SHALL BE ATTACHED TO PIPE.**
SWEAT TYPE
SHALL BE SDR 11.
TYPE "M" COPPER
D 2683, AND/OR
COLD WATER AND
ASTM D 3261
CROSS-LINKED
POLYETHYLENE (PEX)
DRY FIT
INSTALL IN
ACCORDANCE WITH
FUEL GAS PIPING.
SCH. 40 BLACK
150# MALLEABLE
G.C. TO PAINT PIPING EXPOSED TO
NOT APPLICABLE
PLASTIC TUBING
NATURAL GAS)
BLACK IRON.
IRON THREADED
THE WEATHER.
ABOVE GROUND)
POLYVINYL CHLORIDE
OR WELDED.
(CPVC) PLASTIC
* - GAS PIPING SHALL NOT BE INSTALLED UNDER ANY BLDG. OR SLAB AND SHALL ENTER BUILDING ABOVE GRADE. RISERS TO ABOVE GRADE SHALL BE
METALLIC AND COATED WITH APPROVED COATING TO A POINT AT LEAST 6" ABOVE FINISHED GRADE.
** - TRACER WIRE SHALL BE #18 AWG COPPER (OR OTHER APPROVED MATERIALS) AND SHALL RUN THE FULL LENGTH OF BELOW GRADE PIPE AND
TERMINATE ABOVE GRADE AT ONE END.
I ABBREVIATION LEGEND I
A - COMPRESSED AIR
AFC - ABOVE FINISH CEILING
AFF - ABOVE FINISH FLOOR
BFC - BELOW FINISH CEILING
BFF - BELOW FINISH FLOOR
Co - CLEANOUT
CW - COLD WATER
D - EQUIPMENT DRAIN
DN - DOWN
EA - EACH
E.C. - ELECTRICAL CONTRACTOR
FOO - FLOOR CLEANOUT
G - GAS (NATURAL)
G.C. - GENERAL CONTRACTOR
GI - GREASE INTERCEPTOR UNE
GM - GAS METER
GW - GRAY WATER
H.C. - HVAC CONTRACTOR
HW - HOT WATER
ID - INSIDE DIMENSIONS
RY - INDIRECT WASTE
MAX - MAXIMUM
MIN - MINIMUM
MPG - MEDIUM PRESSURE GAS
NO - NITROUS OXIDE
NO. - NUMBER
0 - OXYGEN
OD - OVERFLOW DRAIN
P.C. - PLUMBING CONTRACTOR
PD - PUMPED DISCHARGE
PRESS. - PRESSURE
R - HOT WATER RECIRCULATION LINE
RD - ROOF DRAIN
REQ'D - REQUIRED
S/0 - SAND/OIL INTERCEPTOR LINE
SS - SANITARY SOIL
ST - STORM SEWER
TDH - TOTAL DYNAMIC HEAD PRESSURE
TYP. - TYPICAL
UG - UNDERGROUND
OF - UNDER FLOOR
U.O.N. - UNLESS OTHERWISE NOTED
V - VENT
VAC - VACUUM
VTR - VENT THRU ROOF
WCO - WALL CLEANOUT
WM - WATER METER
WT - WEIGHT
I UNITS LEGEND I
LF - LINEAR FEET
SF - SQUARE FEET
CF - CUBIC FEET
CFM - CUBIC FEET PER MINUTE
GPM - GALLONS PER MINUTE
GPH - GALLONS PER HOUR
GAL - GALLONS
FPM - FEET PER MINUTE
BTU/HR - BRITISH THERMAL UNITS PER HOUR
MBH - BTU/HR X 1000
IN WG - INCHES OF WATER GAUGE PRESSURE
FT WG - FEET OF WATER GAUGE PRESSURE
PSI - POUNDS PER SQUARE INCH
LB - POUNDS
V - VOLTS
A - AMPS
W - WATTS
KW - KILOWATTS
HP - HORSE POWER
HZ - HERTZ
RPM - REVOLUTIONS PER MINUTE
PLUMBING PIPING SCHEDULE
SERVICE
PIPE
FITTINGS
REMARKS
TYPE "K" HARD
WROUGHT COPPER
CU -PH SOLDER
COLD WATER AND
DRAWN COPPER.
SWEAT TYPE
HOT WATER BURIED
O
< o
o
Lu
•
U
OUTSIDE BUILDING.
TYPE "K" SOFT
FLARED TYPE
0zr
two
Om
DRAWN COPPER.
O 0
O
� C7
4_j
COLD WATER AND
TYPE "K" COPPER
CU -PH SOLDER
HOT WATER BURIED
OR
WROUGHT COPPER
OR
WITHIN BUILDING.
TYPE "L" COPPER
SWEAT TYPE
<.2% LEAD SOLDER
TYPE "L" COPPER
WROUGHT COPPER
<.2% LEAD SOLDER
OR
SWEAT TYPE
TYPE "M" COPPER
COLD WATER AND
HOT WATER ABOVE
CROSS-LINKED
POLYETHYLENE (PEX)
DRY FIT
INSTALL IN
ACCORDANCE WITH
GROUND.
PLASTIC TUBING
MFG. INSTRUCTIONS
SCH 80 CHLORINATED
GLUE JOINTS
POLYVINYL CHLORIDE
SOLVENT WELD)
(
(CPVC) PLASTIC
CAST IRON
CAST IRON
STAINLESS STEEL
SANITARY SOIL
HUBLESS
HUBLESS
HARDWARE
BURIED.
SCH 40 PVC DWV
SCH 40 PVC DWV
SOLID WALL
SOLID WALL
CAST IRON
CAST IRON
STAINLESS STEEL
HUBLESS
HUBLESS
HARDWARE
SCH. 40 GALVANIZED.
SCH. 40 GALVANIZED.
2" AND SMALLER
SANITARY SOIL AND
VENT ABOVE GROUND.
ROOF DRAINS.
DWV COPPER.
DWV COPPER SWEAT
CONNECTIONS.
SCH 40 PVC DWV
SCH 40 PVC DWV
NOT IN CAVITIES
SOLID WALL
SOLID WALL
USED AS A RETURN
AIR PLENUM
NOTES: SOLVENT CEMENT MUST BE THIRD -PARTY CERTIFIED AS CONFORMING TO ASTM
F493, SOLVENT CEMENT MUST BE YELLOW, LIMITED TO 1/2" THROUGH 2" PIPE SIZES,
AND PIPE FITTINGS MUST MEET ASTM D2846.
ALL DOMESTIC WATER PIPE, FITTINGS AND FIXTURES MUST COMPLY WITH THE EPA
REDUCTION OF LEAD IN DRINKING WATER ACT OF 2011.
DESIGN SUMMARY FOR PLAN REVIEWER I
GOVERNING CODES: 2018 IPC, 2018 IFGC, 2012 IECC
COMCHECK:
ENVELOPE COMCHECK - YES - ON PLANS/NOT REQUIRED/PROVIDED BY ARCH.
EQUIPMENT COMCHECK - YES - ON PLANS/NOT REQUIRED
GIS APPLIANCE LABEL INFORMATION
EXAMPLE: WH -1
40 MBH (32 MBH)
38 CFH
WH -1 HAS A SEA LEVEL INPUT OF 40 MBH.
WH -1 HAS AN ALTITUDE INPUT OF 32 MBH.
WH -1 HAS AN ALTITUDE FLOWRATE OF 38 CFH.
2"G (100')
38 CFH
GAS PIPE SHOWN HAS AN INSIDE DIAMETER OF
2" & SUPPLIES A FLOWRATE OF 38 CU.FT./HR.
THE LENGTH INDICATES THE MAX DISTANCE
(FROM APPLIANCE TO METER) THAT THIS PIPE
SUPPLIES.
Oe r]r]7(1C T
co co
I- I -
z z
Lu Lu
O O
0 0
0
N
I PLAN DATES I
m
V
Z
Pbbo�l Fs,�.
�"5 00
1�x
w
dc
Ci
W
�
0�/�
VJ
M
M
O
00
W O
�U
Q Lu
00
Q
Lo LU
N
19-016
SHEET NO.
P3-000
a
O
< o
o
Lu
•
U
p 0
0
W
0zr
two
Om
H�
O 0
O
� C7
4_j
m
V
Z
Pbbo�l Fs,�.
�"5 00
1�x
w
dc
Ci
W
�
0�/�
VJ
M
M
O
00
W O
�U
Q Lu
00
Q
Lo LU
N
19-016
SHEET NO.
P3-000
HVAC, PLUMBING, ELECTRICAL, AND GENERAL CONTRACTOR
COORDINATION SCHEDULE
CATEGORY
DESCRIPTION OF WORK
FURNISHED BY
MOUNTED BY
WIRED BY
CONDUCTORS IN 3" CONDUIT.
LOCATING EXISTING
UTILITIES
EXTERIOR.
G.C.
SINGLE PHASE
TRANSFORMERS
INTERIOR.
P.C./E.C.
m'i°.ewn.
PAD UTILITY
TRANSFORMER
EACH TRADE RESPONSIBLE FOR LOCATING
THEIR RESPECTIVE SYSTEMS.
TEMPORARY UTILITIES
TEMPORARY HEAT.
G.C.
^
DELTA -DELTA 30
,a
TEMPORARY ELECTRICAL SERVICE.
E.C.
E.C.
E.C.
CABINET
WATER AND TOILET AND FACILITIES.
G.C.
UNDERCABINET LINEAR FIXTURE.
BUSSED
WEATHERHEAD
I °Fl
CONCRETE
M/E EQUIPMENT PADS, HOUSEKEEPING PADS, CONCRETE
SAWING, PATCHING, CORE DRILLING, AND REPAIR.
G.C.
RECESSED TROFFERS.
WITH
FAULTGROUND CURR NT
STRIP/WRAP FIXTURE.
EXCAVATION
EXCAVATION, BACKFILL, AND CONCRETE OR ASPHAULT
PAVING FOR UTILITIES OR OTHER M/E EQUIPMENT.
G.C.
SURFACE/SUSPENDED FIXTURE.
CURRENT
An
ROOF TOP, FIELD BUILT
EQUIPMENT PLATFORMS
AND DUCT CURBS.
STRUCTURAL FRAMING FOR SUPPORT.
G.C.
BOLLARD FIXTURE.
WITH ADJUSTABLE
FIXTURE.
FIELD BUILT EQUIPMENT PLATFORMS AND DUCT CURBS,
TOP MINIMUM 9" ABOVE FINISHED ROOF.
G.C.
TRIP SETTINGS
O
G.C. TO CONSTRUCT PLATFORM/CURB
FROM 2X10'S AS REQ'D AND CAP WITH
3/4" PLYWOOD AND 40# COATED FELT.
FLASHING OVER THE TOP OF PLATFORMS AND CURBS.H
C
SINGLE FACE WITH INDICATION ARROW
H.C. TO PROVIDE 26 GA. G.S. METAL TOP
EXTENDING 3" DOWN SIDES. ALL JOINTS
SOLDERED WATERTIGHT.
ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM.
G.C.
FUSED
SWITCH
® Q
DIESEL/NATURAL
GAS GENERATOR
EQUIPMENT AND FIXTURE
MOUNTING
STRUCTURAL FRAMING FOR SUPPORT.
G.C.
HANGERS, MOUNTING HARDWARE, ANCHORS, PIPING
STANDS, AND EQUIPMENT LEGS.THEIR
H.C./P.C./E.C.EACH
flY6 A
NEW/EXISTING
TRADE RESPONSIBLE FOR MOUNTING
RESPECTIVE EQUIPMENT.
ROOFING AND ROOFING
PENETRATIONS
PIPE AND ROUND DUCT/VENT ROOFJACKS.
H.C./P.C./E.C.
EACH TRADE RESPONSIBLE FOR
ROOFJACKS REQ'D FOR THEIR EQUIPMENT.
PITCH PANS FOR EQUIPMENT LEGS OR PIPE STANDS.
H.C./P.C./E.C.
vwn A
EACH TRADE RESPONSIBLE FOR PITCH
PANS REQ'D FOR THEIR EQUIPMENT.
DRAIN, OVERFLOW SCUPPERS, AND GUTTERS.
G.C.
WITH MAIN
ROOFING REPAIR AND/OR SEALING OF ROOFING SYSTEM.
G.C.
SYSTEM
CIRCUIT BREAKER
IW6A
PAINTING
EQUIPMENT, DUCTS, PIPES, LOUVERS, AND ETC.
G.C.
BOARD
WITH MAIN
WITH MAIN AND
ACCESS DOORS
FOR M/E EQUIPMENT REQUIRING ACCESS.
H.C./P.C./E.C.
G.C.
EACH TRADE TO FURNISH ACCESS DOORS
AS REQ'D FOR THEIR EQUIP.
FIRE RATED CHASES
FOR GREASE DUCTS, FLUES, DUCTS, AND ETC.
G.C.
I A
ELECTRICAL
CONTROL TRANSFORMERS FOR HVAC EQUIPMENT.
H.C.
E.C.
E.C.
HVAC CONTROL WIRING 48 VOLTS AND LESS.
H.C.
H.C.
WITH FEEDTHRU
HVAC CONTROL WIRING GREATER THAN 48 VOLTS.
E.C.
E.C.
PIPE STEEL
HVAC EQUIP. INTERLOCK WIRING HIGH AND LOW VOLTAGE
E.C.
E.C.
CONDUIT FOR ALL WIRING.
E.C.
E.C.
DISCONNECT SWITCHES.
E.C.
E.C.
E.C.
MOTOR STARTERS TO INCLUDE THERMAL OVERLOADS.
H.C./P.C.
E.C.
E.C.
EACH TRADE TO FURNISH STARTERS AS
REQ'D FOR THEIR EQUIP.
DUCT MOUNTED SMOKE
DETECTORS
INTERFACED WITH BUILDING FIRE ALARM SYSTEM.
F.A.C./E.C.
H.C.
F.A.C./E.C.
H.C. TO PROVIDE ACTUAL DUCT SIZE
MEASUREMENTS.
IN BUILDING W/O FIRE ALARM/DETECTION SYSTEM.
H.C.
H.C.
E.C.
INTERLOCKS W/HVAC SYSTEM FANS.
E.C.
ABBREVIATIONS: E.C.-ELECTRICAL CONTRACTOR, F.A.C.-FIRE ALARM CONTRACTOR, G.C.-GENERAL CONTRACTOR, H.C.-HVAC CONTRACTOR, P.C.-PLUMBING CONTRACTOR
GENERAL ELECTRICAL PROVISIONS
ONE LINE DIAGRAM LEGEND
2(4-250 MCM XHHW AL. - (2)
PARALLEL RUNS CONSISTING
#3 CU GND)3" C. OF
(4) 250 MCM
XHHW ALUMINUM
NUMERICAL ONLY = CIRCUIT
CONDUCTORS IN 3" CONDUIT.
d*
OVERHEAD UTILITY
NL = NIGHT LIGHT (24 HOUR)
SINGLE PHASE
TRANSFORMERS
LINE/LOW VOLTAGE SWITCH
TRANSFORMER
m'i°.ewn.
PAD UTILITY
TRANSFORMER
DIMMER SWITCH
DELTA -WYE 30
TRANSFORMER
RECESSED CAN FIXTURE.
SECONDARY
^
DELTA -DELTA 30
,a
CONNECTION
WALL MOUNTED/VANITY FIXTURE.
TRANSFORMER
CABINET
PENDANT FIXTURE.
>=�
UNDERCABINET LINEAR FIXTURE.
BUSSED
WEATHERHEAD
I °Fl
FUSED SWITCH
�7
�✓
WEATHERHEAD(S)
RECESSED TROFFERS.
WITH
FAULTGROUND CURR NT
STRIP/WRAP FIXTURE.
10/30
RECESSED LINEAR FIXTURE.
INTERRUPTER
SURFACE/SUSPENDED FIXTURE.
CURRENT
An
CIRCUIT BREAKER
FLOOD LIGHT/ACCENT FIXTURE.
TRANSFORMER
BOLLARD FIXTURE.
WITH ADJUSTABLE
FIXTURE.
WITH METER
POLE FIXTURE.
TRIP SETTINGS
O
METER
�.
AUTOMATIC
TRANSFER SWITCH
SINGLE FACE WITH INDICATION ARROW
DUAL FACES EXIT SIGN
(ATS)
COMBO EXIT SIGN AND FROG EYES.
FUSED
SWITCH
® Q
DIESEL/NATURAL
GAS GENERATOR
REMOTE LANDING FIXTURE.
CIRCUIT BREAKER
GROUND
flY6 A
NEW/EXISTING
X 1
FAULT POINT
❑
PANELBOARD
(MAIN LUG ONLY)
vwn A
NEW/EXISTING
PANELBOARD
WITH MAIN
GROUNDING
SYSTEM
CIRCUIT BREAKER
IW6A
NEW/EXISTING
BOARD
WITH MAIN
WITH MAIN AND
UP
SUBFEED CIRCUIT
BREAKERS
I A
(2) 42 SPACE
PANELBOARDS
[ail
WITH FEEDTHRU
WATER BLDG
LIFER DRIVEN
LUGS KIT
PIPE STEEL
ROD
1. ELECTRICAL DRAWINGS
ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND ARE NOT TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM
THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK. VERIFY SPACE REQUIREMENTS, COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE SPACE PROVIDED WITHOUT
VIOLATION OF APPLICABLE CODES, STANDARDS, SPECIFICATION REQUIREMENTS, OR EXTRA CHARGES TO THE OWNER.
BELFAY ENGINEERING WILL OCCASIONALLY PROVIDE PERFORMANCE SPECIFICATIONS FOR CERTAIN SUB—SYSTEMS OF THE DESIGN. ESPECIALLY SYSTEMS THAT RELY ON PROPRIETARY PARTS. IN
SUCH CASES, IT IS TO BE UNDERSTOOD THAT BELFAY ENGINEERING IS RESPONSIBLE FOR A THOROUGH AND COHESIVE PERFORMANCE SPEC AND REVIEW OF SHOP DRAWINGS. THE
CONTRACTOR IS RESPONSIBLE FOR FURNISHING SHOP DRAWINGS AND INSTALLING A WORKING SYSTEM CONSISTENT WITH THE PERFORMANCE SPEC.
2. VERIFICATION OF FIELD CONDITIONS — BEFORE UNDERTAKING EACH PART OF THE WORK, CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH FIELD MEASUREMENTS.
PROMPTLY REPORT IN WRITING TO THE ELECTRICAL ENGINEER ANY CONFLICT, ERROR OR DISCREPANCY.
3. EQUIPMENT FURNISHED BY OTHERS — COORDINATE EXACT ELECTRICAL REQUIREMENTS (VOLTAGE, PHASE, AMPS, AND ETC.) OF EQUIPMENT FURNISHED BY OTHERS BEFORE PERFORMING WORK.
4. PERMITS — APPLY FOR AND PAY FOR ALL PERMITS, FEES, LICENSES AND INSPECTIONS FOR THIS DIVISION OF WORK.
5. CODES — COMPLY WITH ALL APPLICABLE CODES AND UTILITY COMPANY REGULATIONS. IN CASE OF CONFLICT WITH THE CONTRACT DOCUMENTS THE MOST STRINGENT SHALL GOVERN.
6. ACCESS DOORS — FURNISH ACCESS DOORS TO PROVIDE ACCESS TO ALL J—BOXES, PULL BOXES, AND OTHER EQUIPMENT AS REQUIRED. ACCESS DOORS FOR INSTALLATION IN FIRE RATED
CONSTRUCTION SHALL HAVE APPROPRIATE FIRE RATING.
7. ADDING LOADS — BEFORE ADDING ANY LOAD NOT SHOWN ON THE PLANS, TO THE ELECTRICAL SYSTEM, SUBMIT REQUEST IN WRITING TO THE ELECTRICAL ENGINEER FOR APPROVAL.
8. SPECIFIED MANUFACTURERS
AN ACCEPTABLE MANUFACTURER'S NAME AND MODEL NUMBER OF A PRODUCT MAY BE GIVEN FOR AN EXAMPLE. THIS IS THE EQUIPMENT CONTEMPLATED DURING THE DESIGN PROCESS AND
FORMS THE BASIS OF A STANDARD OF QUALITY. VERIFY THE MODEL NUMBER IS STILL ACCURATE AND MEETS ALL THE REQUIREMENTS AS SHOWN ON THE DRAWINGS. IF THERE IS A
DISCREPANCY BETWEEN THE REQUIREMENTS OF THE DRAWINGS AND THE MODEL NUMBER, THE REQUIREMENTS OF THE DRAWINGS SHALL GOVERN. APPROVED EQUALS SHALL BE ALLOWED
UNLESS OTHERWISE NOTED.
9. SUBMITTALS
A. REQUIRED SUBMITTALS — SUBMIT ELECTRONIC COPIES OF THE FOLLOWING INFORMATION FOR APPROVAL
1.) SERVICE EQUIPMENT, PANELBOARDS, LOAD CENTERS, SWITCHES, FUSES, AND CIRCUIT BREAKERS.
2.) LIGHTING FIXTURES.
3.) WIRING DEVICES AND DEVICE PLATES.
B. REVIEW TIME — ALLOW 5 WORKING DAYS FOR REVIEW OF SUBMITTALS. ORDER NO MATERIALS OR BEGIN NO WORK UNTIL ALL SUBMITTALS ARE RETURNED APPROVED.
C. RESUBMISSION — MAKE ALL REVISIONS REQUIRED AND RESUBMIT AS REQUIRED FOR INITIAL SUBMITTAL
10. MISCELLANEOUS MATERIALS — THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS HARDWARE AND MATERIAL NOT SPECIFIED BUT NECESSARY TO PROVIDE A COMPLETE AND
WORKING ELECTRICAL SYSTEM. THIS HARDWARE SHALL INCLUDE, BUT NOT BE LIMITED TO, ALL MISCELLANEOUS CONDUIT FITTINGS AND MOUNTING HARDWARE,
LIGHT FIXTURE MOUNTING HARDWARE, BRACKETS, CONNECTORS, CORDS AND PLUGS.
11. WARRANTIES — GUARANTEE ALL WORKMANSHIP, MATERIAL AND EQUIPMENT AND REPLACE ANY FOUND DEFECTIVE WORK WITHOUT COST TO THE OWNER, FOR A PERIOD OF ONE YEAR AFTER
FINAL ACCEPTANCE.
POWER PLAN LEGEND
_�A (1) 1 -POLE HOME RUN; PANEL A, CIRCUIT #2.
2,4A (1) 2 -POLE HOME RUN; PANEL A, CIRCUIT #2,4.
1,3_5
_ A (3) 1 -POLE HOME RUNS; PANEL A. CKT #1,3,5.
— — — CONDUIT CONCEALED IN WALL OR CEILING.
— — — PVC CONDUIT UNDERGROUND USE.
—USE— USE CABLE; SUITABLE FOR UNDERGROUND USE.
CAPPED CONDUIT.
OJ JUNCTION -BOX.
®v WALL TELEPHONE/DATA/TV OUTLET, 18" AFF UNLESS OTHERWISE NOTED.
3/4" CONDUIT STUBBED UP WALL TERMINATING ABOVE CLG.
0 COMPUTER DATA OUTLET. 3/4" CONDUIT STUBBED UP WALL TERMINATING ABOVE CLG.
AC DUPLEX RECEPTACLE, 18" AFF UNLESS OTHERWISE NOTED; CIRCUIT #5.
WP o5 GF] = GROUNDABOVE/BELOW
TB COUNTER
INTERRUPTER
IG WP = WEATHERPROOF
USB IG = ISOLATED GROUND
USB = USB PORT(S)
0 DOUBLE DUPLEX RECEPTACLE, 18" AFF.
0a SWITCHED RECEPTACLE; SWITCH LEG = a.
® CEILING RECEPTACLE.
® ® FLOOR DUPLEX/D. DUPLEX RECEPTACLE.
® ® FLOOR COMBO DUPLEX/D. DUPLEX RECEPTACLE AND TELE./DATA/TV. SEE NOTE ABOVE.
® SPECIAL RECEPTACLE, REFER TO PANEL SCHEDULE FOR DETAILS.
MULTI -OUTLET ASSEMBLY OR PLUGMOLD.
SENSORS:
OS = OCCUPANCY SENSOR (DUAL TECHNOLOGY)
®®® VS = VACANCY SENSOR (DUAL TECHNOLOGY)
PE
®OO ® DH = DAYYLIGHTLTAIC HARVESTINGRSENSOR
OssmoeE S = SMOKE DETECTOR
CO = CARBON MONOXIDE
S/STROBE = SMOKE WITH STROBE
ELECTRONIC HORN AND STROBE.
TELEPHONE BACKBOARD. (TBB)
NON—FUSED SWITCH; FUSED SWITCH; COMBO MOTOR STARTER; MAGNETIC MOTOR STARTER.
G gg� NEW/EXISTING PANELBOARD.
SCSB = STRUCTURED CABLE SERVICE BOX;
sccsssB PROVIDE (1)120V RECEPTACLE IN SCSB.
® PLUG FUSE SWITCH, 120V 15/20A.
AlCy MOTOR EQUIPMENT.
EF -1 EQUIPMENT BY OTHERS; "EF -1" = PLAN CODE.
TC TIME—CLOCK, 7—DAY, ASTRONOMICAL TIME—KEEPING WITH BATTERY BACK—UP.
cB CARD—READER, +48" AFF UNLESS OTHERWISE NOTED. 3/4" CONDUIT
STUBBED UP WALL TERMINATING ABOVE CLG.
ELECTRICAL MATERIALS AND METHODS
LIGHTING PLAN LEGEND
Al c
ALPHANUMERIC = PLAN CODE
�ZZ.
Q� v 01 ro
LOWERCASE LETTERS = SWITCH LEG
. 2
NUMERICAL ONLY = CIRCUIT
WM
HATCH FILL = EGRESS
Z a) c �
NL = NIGHT LIGHT (24 HOUR)
a a
LINE/LOW VOLTAGE SWITCH
3 -WAY SWITCH
DIMMER SWITCH
RECESSED CAN FIXTURE.
RECESSED DIRECTIONAL WALL FIXTURE.
J®
{ }
CEILING MOUNTED FIXTURE.
y
WALL MOUNTED/VANITY FIXTURE.
PENDANT FIXTURE.
>=�
UNDERCABINET LINEAR FIXTURE.
�
TAPE/ROPE/FESTOON FIXTURE.
Q,,Q
X
CEILING FAN WITH LIGHT KIT.
El E;:]2'X2'/2'X4'
RECESSED TROFFERS.
I--
STRIP/WRAP FIXTURE.
m
RECESSED LINEAR FIXTURE.
0
SURFACE/SUSPENDED FIXTURE.
TRACK FIXTURE.
OQ
FLOOD LIGHT/ACCENT FIXTURE.
0
BOLLARD FIXTURE.
OPEDESTRIAN
FIXTURE.
0-0
POLE FIXTURE.
E
STEP FIXTURE.
Q
i T Ip
EXIT SIGNS:
SINGLE FACE EXIT SIGN
SINGLE FACE WITH INDICATION ARROW
DUAL FACES EXIT SIGN
COMBO EXIT SIGN AND FROG EYES.
BATTERY POWERED FROG EYES.
REMOTE LANDING FIXTURE.
PART 1 GENERAL - THIS SECTION DESCRIBES THE MATERIALS AND METHODS COMMON TO THE ELECTRICAL DIVISION OF WORK.
PART 2 PRODUCTS
2.1 RACEWAY SYSTEMS
A. ABOVE GROUND INTERIOR - HOT DIP GALVANIZED AS REQUIRED BY CODE OF EMT, IMC, OR RMC.
B. BURIED AND UNDER CONCRETE SLABS - SCHEDULE 80 PVC W/ASPHALT COATED RMC ELBOWS WHERE PENETRATING SURFACE.
2.2 CABLE SYSTEMS - CONCEALED SPACES ONLY, TYPE AC OR MC CABLE AS ALLOWED BY CODE.
2.3 CONDUCTORS
A. CONDUCTORS SHALL BE COPPER AND MINIMUM SIZE SHALL BE #12 AWG (20A MOCP) OR #14 (15A MOCP) EXCEPT AS OTHERWISE NOTED.
B. INSULATION SHALL BE THWN-THHN EXCEPT AS OTHERWISE NOTED.
C. ALL CIRCUIT CONDUCTORS SHALL BE RUN WITH EQUIPMENT GROUNDING AND WILL USE CONDUIT UNLESS OTHERWISE NOTED IN ACCORDANCE WITH NEC 250.122.
2.4 PANELBOARDS - PROVIDE PANELBOARDS W/BOLT-ON CIRCUIT BREAKERS EXCEPT AS OTHERWISE NOTED. SEE PANEL SCHEDULE FOR CAPACITY, RATINGS, SPACES, VOLTAGE, PHASE,
MOUNTING, AND OTHER OPTIONS TO BE PROVIDED.
2.5 LOAD CENTERS - PROVIDE LOAD CENTERS W/PUSH-ON CIRCUIT BREAKER EXCEPT AS OTHERWISE NOTED. SEE PANEL SCHEDULE FOR CAPACITY, RATINGS, SPACES, VOLTAGE, PHASE,
MOUNTING, AND OTHER OPTIONS TO BE PROVIDED.
2.6 GFCI - ALL GFCI SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION PER NEC 210.8.
2.7 ALL CONNECTED TERMINATIONS, CONDUCTORS, AND DEVICES SHALL HAVE A MINIMUM TEMPERATURE RATING OF 75'C, UNLESS OTHERWISE NOTED.
PART 3 EXECUTION.
3.1 RACEWAY SYSTEMS
A. RUN CONDUIT PARALLEL WITH AND AT RIGHT ANGLES TO BUILDING LINES.
B. PROVIDE 1 EMPTY 3/4" CONDUIT FOR EVERY 3 UNUSED SPACES IN FLUSH MOUNTED PANELBOARDS OR LOAD CENTERS.
C. PROVIDE FLEXIBLE CONDUIT ON CONNECTIONS TO VIBRATING EQUIPMENT. CONDUIT AND GROUNDING MEANS SHALL BE PER NEC.
3.2 IDENTIFICATION OF EQUIPMENT
A. IDENTIFY EACH DISCONNECT SWITCH, TRANSFORMER, PANELBOARD, LOAD CENTER, AND ALL OTHER ELECTRICAL EQUIPMENT IDENTIFIED BY A PLAN CODE ON THE DRAWINGS.
B. NAMEPLATES SHALL BE ENGRAVED IN LAMINATED PLASTIC, 3/8" HIGH AND ATTACHED WITH SCREWS.
C. ALL PANELBOARDS AND LOAD CENTERS SHALL HAVE TYPE -WRITTEN DIRECTORIES INSERTED ON THE INSIDE FACE OF THE DOOR IDENTIFYING EACH CIRCUIT.
D. ALL COMPONENTS OF EMERGENCY CIRCUITS SHALL BE PAINTED RED.
3.3 LIGHTING
A. ALL EGRESS LIGHTING AND EXIT SIGNS SHALL BE PROVIDED WITH A CONSTANT HOT PER EACH CIRCUIT THAT IS INDICATED PER PLAN.
DESIGN SUMMARY FOR PLAN REVIEWER
GOVERNING CODES: 2017 NEC, 2018 IECC
COMCHECK:
LIGHTING COMCHECK — YES — ON PLANS
�,w o
v V � N
v
iN N
�ZZ.
Q� v 01 ro
W We M
W
JLu
Z
WM
c� LL
Z a) c �
XY W 2uu M.
z z
w w
0 0
I au.II_var:&�
�m
V
Z
C7
C7
O
O
co
w0
�U
Q Lu
�-- 0
c
Q
Lo LU
0)
N
19-016
SHEET NO.
E3-000
..............
TtUG%
"i
227 5
� IIIIIIIIIIIINU\\\
�v V� N
F=
N
ZiN N
oQ
Q� NOI M
�Wi � M
W
Z
JW mol g
LL
w
IZw .�Y
Lu
a00W2um
STORAGE
CH
UNIT—"
TYPICAL URE 1&2
EXIIMM
UNITTYP
REPLACEMENT SHOWN E3-201
11p REMAN
802:
FOR THIS UNIT.
z
z
z
z
LAUNDRY []
w
w D
Z
UO
>
O
Ll o O
o O
U
co
N
co
„
Cr'I
w
D
O
U
LL
K
O
U
{`Il'}
0 0
Ll 0 0
0
N
0
N
0
N
O
N
O
N
O
N
Wo
NN
0
O O
O
PLAN DATES
MECHANICAL
W
UNIT B2
W
UNIT TYPE: 3-2.6
802 S.F.
W
o
H—
0 0
of Of m
C
O
0o�
• �--� U
O U N
W
�Lu
C
0
H�
�
O 0
O
7
UP
1 ,
VJ
UNIT
NOTES (2 UNITS IN BASEMENT)
COMMON AREA NOTES
v
1.
BRANCH CIRCUIT TERMINATION POINTS DO NOT MOVE, BUT ALL FIXTURES
WILL BE
1. REPLACE EXISTING CORRIDOR LIGHTS
WITH LED FIXTURES.
ATTACH CU PIGTAILS TO AL WIRING AS
+
REPLACED/UPGRADED.
DONE FOR UNIT WIRING.
,
2.
ATTACH CU PIGTAILS TO ALL ALUMINUM BRANCH CIRCUIT WIRING AT EVERY OUTLET AND SPLICE BOX
FOR WIRE SIZE #8 AND SMALLER CONDUCTORS. USE ONLY COPALUM OR ALUMICONN CONNECTORS.
BASEMENT.
2. REPLACE EXISTING EXIT LIGHTING WITH NEW FIXTURES WITH EM LIGHTING
WHERE APPROPRIATE.
/051' p���4\c�'
!
3. REPLACE EMERGENCY EXIT LIGHTING.
M
� � J
3.
GFCI RECEPTACLES TO BE USED IN ALL LOCATIONS SPECIFIED IN NEC 210.8
II��
4.
RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE TAMPER—RESISTANT PER 2017 NEC
`J
406.12 REQUIREMENTS.
Z
5.
REPLACE OR ADD SMOKE ALARMS.
0
6.
REPLACE ZINSCO BRAND ELECTRICAL PANELS, IN UNITS THAT HAVE THEM.
J
7.
A MAXIMUM OF 12 UNITS IN BUILDING MAY HAVE THEIR EXISTING RANGE
HOOD REPLACED WITH A
MICROWAVE.
M
W
I
W
0L
C`7
O
n(
O
`J
00
Lu
vJ
Q W
� D
CO
H
LU
QLo
O) 2
U��
19-016
SHEET NO.
®Norm
BLDG 3 BASEMENT
E3-100
SCALE: 1/8" = 1 0"
DEMO
HAL
FLOOD
CIF
(N) CONC. RAMP TO EXTI
FOLLOW ADA STANDARDS
(E) CONC. STOOP &
BRICK HAND RAIL WALLS
TO BE DEMOLISHED &
REBUILT NO LESS THAN
1/2" BELOW FINISH FLOOR
UNIT NOTES (10 UNITS ON FIRST FLOOR
1. BUILDING 3 LEVEL 1 HAS 2 UNITS CONVERTED TO BE ADA COMPLIANT. THESE WILL REQUIRE ALL NEW
CIRCUITING INCLUDING NEW PANEL.
2. FOR REMAINING 8 UNITS BRANCH CIRCUIT TERMINATION POINTS DO NOT MOVE, BUT ALL FIXTURES WILL
BE REPLACED/UPGRADED.
3. ATTACH CU PIGTAILS TO ALL ALUMINUM BRANCH CIRCUIT WIRING AT EVERY OUTLET AND SPLICE BOX
FOR WIRE SIZE #8 AND SMALLER CONDUCTORS. USE ONLY COPALUM OR ALUMICONN CONNECTORS.
4. GFCI RECEPTACLES TO BE USED IN ALL LOCATIONS SPECIFIED IN NEC 210.8
5. RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE TAMPER—RESISTANT PER 2017 NEC
406.12 REQUIREMENTS.
6. REPLACE OR ADD SMOKE ALARMS.
7. EXTERIOR PATIO LIGHTS — ADD NEW 'DG' FIXTURES AT PATIOS. USE HOUSE PANEL CIRCUIT, AND
CONTROL WITH PHOTO SENSOR.
8. REPLACE ZINSCO BRAND ELECTRICAL PANELS, IN UNITS THAT HAVE THEM.
9. A MAXIMUM OF 12 UNITS IN BUILDING MAY HAVE THEIR EXISTING RANGE HOOD REPLACED WITH A
MICROWAVE.
I ST FLOOR
BLDG 3 1 ST FLOOR
SCALE: 1/8" = 1' — 0"
COMMON AREA NOTES
1. FOR ALL FIXTURE REPLACEMENT WHERE EXISTING WIRING IS AL, ATTACH CU PIGTAILS AS DONE
FOR UNIT WIRING.
2. REPLACE EXISTING CORRIDOR LIGHTS WITH NEW (TYPE 'CD') FIXTURES. USE BATTERY BACKUP
(TYPE 'CD—EM') WHERE SHOWN.
3. REPLACE EXISTING SIDE EXIT LIGHT WITH NEW FIXTURE (1—TYPE 'CG3').
4. ADD NEW EXTERIOR EXIT LIGHTING (2—TYPE 'CG').
5. REPLACE EXIT LIGHTS (TYPE 'X1').
6. REPLACE HALLWAY RECEPTACLES WITH NEW DECORA TYPE RECEPTACLES.
7. DEMO EXISTING ROOF MOUNTED PARKING FLOOD LIGHT AND RE—USE CIRCUIT FOR NEW EXTERIOR
LIGHTING.
gEL
v
�Z v
� V
N o1
W We
W
JW -Fuo,
c
mZ vC
Lu 2u
F
z
w
Z
O 0
d p
K c o
U Z N
W O T
p U K
0 0
N N
O O
N N
O r
W O N
QV V
O O
I PLAN DATES I
a
a
P4
fm
V
Z
00
�a�
af
w��
poro
0U
Zm
W o
� p m
O 0
V O
LL 0
LW
LL
V J
Y)
Q
W
Q
U
C`7
C`7
O
O
00
w0
�U
Q Lu
=U
�o
00 Fy
�Q
Lo W
rn=
N
19-016
SHEET NO.
E3-101
eIEREe FT:9R`a_
�O�PPO
V V� N
_
N
Zyc q
Z. V._ M
49
BALCO LCONY
Z
W W W M
mol g
LL
JW
.�Y
IZw
W 2c m
CE
•
UNIT 120
UNIT TYPE: 3-2.5
W
UNIT 116
UNIT 117 UNIT 118
UNIT 119
698 S.F.
NIT TYPE: 3-2.3
UNIT TYPE: 3-2.2 UNIT TYPE: 3-2.2
UNITTYPE:3- 2
DEMO EXISTING 8OW
698 S.F.
806S- --- S.F.
❑ 806 S.F.
��
FLUORESCENT FIXTURES
o REPLACE EXISTING CORRIDOR WALL o
o
z
z
REPLACE WIT
SCONCE WITH NEW LED WALL SCONCE.
LED PENDANT LI
O jEXISTING CIRCUITING TO REMAIN.
/
O
El
G3
�
�
13'- 10"
0 0
(TYPICAL OF ALL)
0 0
E
(�
0
Q
Oo
Q
0
00
//
O o
�J
®
BA CO Y
-
a
TO CD
CD CD
CD
00
Of
F
O
F
BEL
X CD
CD CORRIDOR
Cp
Cp
o
o
o
Lx_
X2
X1
Ll
o O
° °
af
00
Fi
CO Y
O
O
D
Ll
❑_0
0rel_Q
�l
0
W
O
O
NN
O
O
®
®
®
0
PLAN DATES
0 0 0
° O 0
0
°
0
0
0
0
UNIT 11
UNIT 114 UNIT 113
UNIT 112
a
UNIT TYPE: 3-2.3
UNIT TYPE: 3-2.2 UNIT TYPE: 3-2.2
4
UNIT TYPE: 3-2.2
698 S.F.TYPICAL
FIXTURE -5 S.F. F.
611 S.F.
UNIT 111
REPLACEMENT SHOWN 3&4
UNIT TYPE: 3-2.5
` ^ W o
FOR THIS UNIT. E3-ZO1
698 S.F.
®
�v O o
O
z f
O Lu 0 �
c'
00ro
�I
N
0zm
W O
00 m
�lE=
O 0
O
BALCO LCONY
BALCON �G
+�
UNIT
NOTES (10 UNITS ON SECOND FLOOR)
COMMON AREA NOTES
v
1.
BRANCH CIRCUIT TERMINATION POINTS DO NOT MOVE, BUT ALL
FIXTURES AND DEVICES WILL BE
1.
FOR ALL FIXTURE REPLACEMENT WHERE EXISTING WIRING IS
AL, ATTACH CU
PIGTAILS
AS DONE
, �402
REPLACED/UPGRADED.
FOR UNIT WIRING.
D=y.
2.
ATTACH CU PIGTAILS TO ALL ALUMINUM BRANCH CIRCUIT WIRING
AT EVERY OUTLET AND SPLICE BOX 2NDFLOOR
2.
REPLACE EXISTING CORRIDOR LIGHTS
'CD—EM')
WITH NEW (TYPE 'CD')
FIXTURES. USE
BATTERY BACKUP
M
J
FOR WIRE SIZE #8 AND SMALLER CONDUCTORS. USE ONLY COPALUM OR ALUMICONN CONNECTORS.
(TYPE WHERE SHOWN.
3.
GFCI RECEPTACLES TO BE USED IN ALL LOCATIONS SPECIFIED
IN NEC 210.8
3.
REPLACE EXIT LIGHTS (TYPE 'X1')
�
4.
RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL
BE TAMPER—RESISTANT PER 2017 NEC
4.
REPLACE HALLWAY RECEPTACLES WITH NEW DECORA TYPE RECEPTACLES.
Z
406.12 REQUIREMENTS.
5.
DEMO EXISTING FLUORESCENT FIXTURE AT HALLWAY END AND REPLACE WITH
LED
PENDANT
Q
5.
REPLACE OR ADD SMOKE ALARMS.
LIGHT.
J
6.
REPLACE THE 5 EXTERIOR BALCONY LIGHTS WITH NEW (TYPE 'DG')
FIXTURES.
�M�•y•�
7.
REPLACE ZINSCO BRAND ELECTRICAL PANELS IN UNITS THAT HAVE THEM.
W
8.
A MAXIMUM OF 12 UNITS IN BUILDING MAY HAVE THEIR EXISTING
RANGE HOOD REPLACED WITH A
MICROWAVE.
I
W
0L
C`7
O
n( O
LJ 00
Lu
Y)
Q W
� D
Co
H
UJ
QLo
rn 2
U��
19-016
®NoRTH BLDG 3 2ND FLOOR
SHEET NO.
SCALE: 1/8"
= 1'
0"
E3-102
UNIT DIAMOND NOTES
1O (NOT USED)
O PROVIDE A GFCI DUPLEX RECEPTACLE LOCATED BELOW KITCHEN SINK FOR CONNECTION
OF GARBAGE DISPOSAL AND DISHWASHER. PROVIDE AN AIR -SWITCH FOR DISPOSAL
CONTROL, AS REQUIRED.
O3 (NOT USED)
O4 1 SWITCH FOR FAN CONTROL, 1 SWITCH FOR LIGHT CONTROL.
ACCESSIBLE UNITS GENERAL NOTES
1. CONTROLS, OPERATING MECHANISMS AND HARWARE INTENDED FOR OPERATING BY
THE OCCUPANT INCLUDING SWITCHES THAT CONTROL LIGHT AND VENTILATION AND
ELECTRICAL CONVENIENCE OUTLETS IN ACCESSIBLE SPACES, ALONG ACCESSIBLE
ROUTES OR AS PARTS OF ACCESSIBLE ELEMENTS SHALL BE ACCESSIBLE. (IBC
1109.13)
2. ALARM SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISIBLE ALARMS (HARD -WIRE
EQUIPMENT) AND COMPLY WITH IBC 907.9.1 TABLE 907.9.1.3.
3. LIGHT SWITCHES IN ACCESSIBLE UNITS SHALL BE LOCATED AT +38" AFF UNLESS
NOTED OTHERWISE.
4. CONVENIENCE RECEPTACLES SHALL BE LOCATED AT +18" AFF UNLESS NOTED
OTHERWISE.
5. TYPICAL UNIT GENERAL NOTES AND SHEET NOTES ON THIS SHEET ALSO APPLY TO
ACCESSIBLE UNITS.
6. ACCESSIBLE UNITS SHALL COMPLY WITH ANSI -A117.1. RE: GENERAL NOTES ON
THIS SHEET FOR ADDITIONAL ACCESSIBLE UNIT INFORMATION AND REQUIREMENTS.
7. COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE OPTIONAL REMOTE
ACCESSIBLE CONTROLS FOR RANGE HOOD/LIGHTS PRIOR TO ORDERING OR
INSTALLING HOOD EQUIPMENT.
8. PROVIDE REMOTE SPST TOGGLE SWITCH FOR CONTROL OF RANGE HOOD VENT/LIGHT
AT COUNTER HEIGHT. VERIFY EXACT LOCATION WITH MILLWORK
DRAWINGS/ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH -IN.
9. ACCESSIBLE SLEEPING ACCOMMODATIONS SHALL HAVE A VISUAL ALARM CONNECTED
TO THE BUILDING EMERGENCY ALARM SYSTEM OR SHALL HAVE A STANDARD 110V
ELECTRICAL RECEPTACLE INTO WHICH SUCH AN ALARM COULD BE CONNECTED.
INSTRUCTIONS FOR USE OF THE AUXILIARY ALARM OR CONNECTION SHALL BE
PROVIDED.
TYPICAL UNIT GENERAL NOTES
1. COORDINATE ALL LUMINAIRE LOCATIONS WITH GENERAL CONTRACTOR AND ALL
OTHER TRADES PRIOR TO ROUGH -IN AND LOCATE ALL LUMINAIRES TO AVOID
DUCTWORK, DEVICES, ETC. TO SUIT FIELD CONDITIONS.
2. DWELLING UNIT CONVENIENCE RECEPTACLE OUTLETS SHALL BE PROVIDED AS
INDICATED ON THE DRAWINGS AND SHALL ALSO COMPLY WITH NEC 210.52
REQUIREMENTS. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE
AND LOCATE ALL GENERAL PURPOSE CONVENIENCE OUTLETS AS REQUIRED PER
CODE WHETHER INDICATED ON THE DRAWINGS OR NOT. MOUNT AT +18" AFF
UNLESS NOTED OTHERWISE. THE BOTTOM OF RECEPTACLE SHALL BE A MINIMUM
OF 15" AFF. ABOVE COUNTER RECEPTACLES SHALL NOT EXCEED 46" AFF
MEASURED TO THE CENTERLINE OF THE HIGHEST RECEPTACLE.
3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE PROPER BRANCH
CIRCUITING AND COMPLIANT DEVICES THROUGHOUT ALL DWELLING UNITS PER NEC
210 REQUIREMENTS.
4. ALL 120V SINGLE PHASE, 15 AND 20A BRANCH CIRCUITS SUPPLYING OUTLETS
INSTALLED IN ALL ROOMS SPECIFIED IN 2017 NEC 210.12(A) SHALL BE
PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE,
INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.
5. 120 VOLT SMOKE ALARMS SHALL BE PROVIDED AND INSTALLED ON THE CEILING
OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY
OF BEDROOMS AND IN EACH ROOM USED FOR SLEEPING PURPOSES IN
ACCORDANCE WITH IBC 907.2.10.1.2.
6. PENETRATIONS IN FIRE RATED ASSEMBLIES SHALL COMPLY WITH IBC 712.3.2
REQUIREMENTS.
7. LIGHT SWITCHES SHALL BE LOCATED AT +48" AFF TO THE TOP OF TOGGLE IN ON
POSITION UNLESS NOTED OTHERWISE.
8. REFER TO ACCESSIBLE UNIT NOTES FOR ADDITIONAL INFORMATION AND
REQUIREMENTS FOR ACCESSIBLE UNITS. ACCESSIBLE UNITS ARE IDENTIFIED AS
TYPE "A" UNITS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND
ADDITIONAL INFORMATION AND REQUIREMENTS.
9. APARTMENT WIRING AND DEVICE LAYOUTS ARE TYPICAL FOR ALL SIMILAR DWELLING
UNIT TYPES UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR SHALL BE
RESPONSIBLE TO ADAPT LAYOUT(S) INDICATED FOR ALL SIMILAR UNITS AS
REQUIRED.
10. COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE REMOTE ACCESSIBLE
CONTROLS FOR RANGE HOOD/LIGHTS PRIOR TO ORDERING OR INSTALLING HOOD
EQUIPMENT.
11. RECEPTACLES IN ALL AREAS SPECIFIED IN NEC 210.52 SHALL BE
TAMPER-RESISTANT PER 2017 NEC 406.12 REQUIREMENTS.
12. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL BRANCH CIRCUIT WIRING WITHIN
DWELLING UNITS PER 2017 NEC 210.52 REQUIREMENTS. REFER TO TYPICAL UNIT
PANEL SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS NOT
INDICATED HEREON.
13. PROVIDE SWITCHED 20A 120V RECEPTACLE UNDER COUNTER FOR GARBAGE
DISPOSAL. VERIFY LOCATION WITH PLUMBING CONTRACTOR PRIOR TO ROUGH -IN.
1/2 -HOT 20A 120V RECEPTACLE UNDER COUNTER FOR DISHWASHER (BREAK
STRAP ON RECEPTACLE FOR DUAL -CIRCUIT CONFIGURATION. RE: PROVIDE
2 -POLE CIRCUIT BREAKER PER CODE REQUIREMENTS).
14. PROVIDE SINGLE -STATION 120V COMBINATION SMOKE ALARM/ CO SENSOR WITH
BATTERY BACKUP PER IBC 907.2.10.1.2 AND 907.2.10.2. WHERE MORE THAN
ONE ALARM IS REQUIRED WITHIN AN INDIVIDUAL DWELLING UNIT, THE ALARMS
SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE
ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE DWELLING UNIT.
15. DUPLEX RECEPTACLES MOUNTED ABOVE COUNTER TOPS SHALL BE MOUNTED SUCH
THAT THE TOP OF THE RECEPTACLE DOES NOT EXCEED 46" AFF.
16. UNDER -COUNTERTOP RECEPTACLES SHALL BE MOUNTED NO MORE THAN 12
INCHES BELOW THE COUNTERTOP AND SHALL NOT BE LOCATED WHERE THE
COUNTERTOP EXTENDS MORE THAN 6 INCHES BEYOND ITS SUPPORT BASE.
REFER TO NEC 210.52(C)(5) EXCEPTION TO (5).
17. ALL KITCHEN COUNTER -TOP RECEPTACLES SHALL SHALL COMPLY WITH ALL FHA
REQUIREMENTS.
18. EXISTING HVAC EQUIPMENT TO BE RECONNECTED TO NEW UNIT LOAD CENTER.
STROBEO
RS
STROBE
STROBEO
LINE OF
FLR. ABOVE
DF
q,r
DF
n,p
ro
LINE OF
FLR. ABOVE
O
WP
UNIT 105
z
NIT TYPE: 3- MIQRQ
698 S.F. AFI
TYPE A AFI
W
2
DISH.
HOOD DISP.
RANGE
-� REAC
+414„ GFS 84F.
AC
" GF6 GFI
BLDG 3 ADA
D�k
PAINT ALL WALL
-(#8-3 CU)NM
REPLACE ALL W
UNIT POWER
SCALE: 1/4" = 1' - 0
+84"
5
r
DA
DA
°'L UNIT 105
NIT TYPE: 3-2.
698 S.F. DA�
TYPE A
110
PAINT ALL WALL
REPLACE ALL W
LIGHTING
1/4" = 1' - 0"
. �a,
0
0
00
Lu
O
LU
Q Lu
_ Q
�-- 0
00 -
Q
Lo W_
N
0)
19-016
SHEET NO.
E3-200
z
z
W
W
Z
>
a
C,cl
U
co
N
co
(n
WOE:
Z
Z
O
D
U
K
U
0
N
0
N
0
N
W
F__
O
N
N
0
0
0
PLAN DATES
a
Oo
zOf m
O
C,
0
• P�1
U
OUN
W
O w o
E-
U Q
H�
O 0
O
�O
r^
/1
0
0
00
Lu
O
LU
Q Lu
_ Q
�-- 0
00 -
Q
Lo W_
N
0)
19-016
SHEET NO.
E3-200
````PPO ..E......
rT
�9
`O •c tog
REPLACE EXISTING SWITCHES
�� ^
WITH NEW (TYPICAL OF ALL SHOWN).
REPLACE EXISTING LIGHT FIXTURES
WITH NEW. ALL LOCATIONS AND
OF
49� uc
1% WaWITH
REPLACE EXISTING RECEPTACES
WIRING IS EXISTING TO REMAIN.
D O
-g
NEW (TYPICAL OF ALL
SHOWN). ALL LOCATIONS AND
10a
Lu
JZ `-'� c
ACS
WIRING IS EXISTING TO REMAIN.
i
��UNIT
B1
GFI
u,41T B1
'1
mW2s mUNIT
TYPE: 3-2.6
UI41T TYPE: 3-2.6�
1
802 S.F.
� 02 S.F.
W
AC
GFI
i
z
z
z
z
AC
DE
`
w
�
w
�
GFI
O
O
O
a
o
cl
DISP.
10
DH DF
r
C)
�
co
N
�
co
DISH. GFI
1
DA 0
00
Z
Of0
Z
O AC
0
N
0
N
0
N
REF.AC HOOD AC GFI
OIL:
W
O
N
N
GFI GFI
Q�
O
0
0
0
0
PLAN DATES
RANGE
� a
F-1 o o n o o UNIT FIXTURE REPLACEMENT DIAMOND NOTES
OADD GFCI RECEPTACLE BELOW KITCHEN SINK FOR CONNECTION OF DISHWASHER IF
mtzt a
CURRENTLY HARD -WIRED.
` ^ jT4 '0
UNIT3-2.6
P0WER
UNIT
3-2.6 LIGHTING
O ADD FAN SUPPORT BAR IF NOT CURRENTLY INSTALLED.
P4 0
0,
1SCALE
1/4" = 1' - 0"
%
SCALE 1/4" = 1' - 0"
O WITH UP TO A MAXIMUM OF 12 UNITS, CONVERT HARD -WIRED HOOD FAN TO
RECEPTACLE FOR MICROWAVE. ENSURE MICROWAVE IS ON DEDICATED CIRCUIT. IF
O U O p
• rj
UNABLE TO SUPPLY DEDICATED CIRCUIT, REPLACE EXISTING RANGE HOOD WITH NEW
W O z m
RANGE HOOD.
o
OIF EXISTING UNIT PANEL IS ZINSCO BRAND, REPLACE WITH NEW 100A PANEL.
x °� 0
VJ
DISP.
DISH.
v
0
1
♦
o o
�Gi/pyo
ACAC o GFI
ac
AC
®
`y y`
GFI GFI
GFI
DEF__DB
g .
DF �
M
O
4DD
AC
Z
GFIREF. AC O
GFO3
HOOD
O0
RANGE
UNIT 114
DCUNIT
114
4
UNIT TYPE: 3-2.2
UI
-
-----IT TYPE: 3-2.2 UI806
NIRING
S.F.
""' `' rEPLACE EXISTING SWITCHESREPLACE
EXISTING RECEPTACES
/
ITH NEW (TYPICAL OF ALL SHOWN).
WITH NEW (TYPICAL OF ALL
EPLACE EXISTING LIGHT FIXTURES
uiITH
HOWN). ALL LOCATIONS AND
WIRING IS EXISTING TO REMAIN.
NEW. ALL LOCATIONS AND
IS EXISTING TO REMAIN.
Cy)
DF i
DF
O
00
O
O
0
W
Q Lu
� 0
0
Q�
A/C
00 -
W � Q
Lo LLJ
BALCONYGFl
E
BALCON E
U
19-016
SHEET NO.
UNIT 3-2.2
POWER
UNIT
3-2.2 LIGHTING
3
SCALE: 1/4" = 1' - 0"
SCALE: 1/4" = 1' - 0"
E3-201
PARTNER
Engineering and Science, Inc.
ASBESTOS & LEAD-BASED
PAINT SURVEY REPORT
Caesar's Square Apartments
9235-9355 West 48th Avenue
Wheat Ridge, Colorado 80033
o¢ober 2,2019
Partner Project No. 19-258685.2
Prepared for'.
1" Bank
4350 Waaswonb BoweoaN
Wheat Ridge, CO 80033
PARTNER
Engineering and Science, Inc:
October 2, 2019
David Schafer
1st Bank
4350 Wadsworth Boulevard
Wheat Ridge, CO 80033
303-456-2182
david.schaferCcbefirstbank.co m
Subject: Asbestos and Lead-based Paint Survey Report
Caesar's Square Apartments
9235-9355 West 48th Avenue
Wheat Ridge, Colorado 80033
Partner Project No. 19-258685.2
Dear Mr. Schafer:
Partner Engineering and Science, Inc. (Partner) is pleased to provide the results of the Asbestos &
Lead-based Paint Survey of the abovementioned address (the "subject property'. This survey was
performed in general conformance with the scope and limitations as detailed in our fee proposal.
This survey included a site reconnaissance as well as sampling and analysis. An assessment was
conducted, conclusions stated, and recommendations outlined, as necessary.
We appreciate the opportunity to provide environmental services to 1' Bank. If you have any
questions concerning this report, or if we can assist you in any other matter, please contact me at
(715) 572-1408.
Sincerely,
Partner Engineering and Science, Inc.
.
AJ Nosekk
National Client Manager
2154 Torrance Blvd., Suite 200, Torrance, CA 90501 0 Phone 800-419-4923 0 Fax 866-928-7418
TABLE OF CONTENTS
1.0
INTRODUCTION ...................................................................................................................................................
I
1.1
Property Description .........................................................................................................................................
1
1.2
Purpose and Scope ...........................................................................................................................................
1
1.3
Methodology ......................................................................................................................................................
1
2.0
ASBESTOS/LEAD SURVEY ...............................................................................................................................
4
2.1
Visual Inspection ................................................................................................................................................
4
2.2
Testing Results ....................................................................................................................................................
4
3.0
CONCLUSION ........................................................................................................................................................
9
4.0
LIMITATIONS ......................................................................................................................................................
11
5.0
SIGNATURES OF PROFESSIONALS ...........................................................................................................
12
Appendices
Appendix A
Laboratory Analysis and Chain -of -Custody
Appendix B
Sample Locations
Appendix C
Certifications
Appendix D
Photographic Documentation
Asbestos and Lead-based Paint Survey
Project No. 19-258685.2
October 2, 2019 PARTNER
Page i
1.0 INTRODUCTION
1.1 Property Description
1.2 Purpose and Scope
The purpose of this asbestos survey and lead-based paint inspection (survey) was to sample and
analyze suspect asbestos -containing materials (ACM) and suspect lead-based paint (LBP) which
could present an exposure risk during potential renovation activities. The suspect materials
sampled during the survey were limited to accessible areas within the interior and exterior of the
building. No renovation scope was provided to Partner prior to conducting the survey.
Twenty-six (26) units were accessed at the site to evaluate the presence of suspect ACM and LBP.
1.3 Methodology
ASBESTOS
Suspect ACM were sampled according to the guidelines set forth in 40 CFR Part 763, and later
analyzed using the Polarized Light Microscopy (PLM) method in accordance with the EPA
reference method 600/R-93/116 for Determination of Asbestos in Bulk Building Materials.
The United States Environmental Protection Agency (USEPA) as set forth in 40 CFR 763, defines a
homogeneous area as "an area of surfacing material, thermal system insulation material, or
miscellaneous material that is uniform in color and texture." The regulation requires that a
minimum number of representative samples be collected from each homogeneous area to
confirm that the material is not an ACM. If asbestos is identified in any samples from a
homogeneous area, the entire homogeneous area is considered to contain asbestos.
The aforementioned testing and analytical constraints can affect the findings and
recommendations of this survey. Specifically, no assurance is given regarding the asbestos
content of the samples beyond these parameters.
The ACM most likely to release asbestos fibers are those which are in a friable state. Friability
describes the condition of asbestos. The definition of friable is any material, when dry, that is
capable of being crumbled, pulverized or reduced to powder by hand pressure (40 CFR 763).
Non -friable sources of asbestos are materials containing cement or asphalt binder which may
become friable and release fibers if the sources are exposed to actions such as abrasion, drilling,
Asbestos and Lead-based Paint Survey PARTNER
Project19-258685.2
Octoberr 2, 2, 2019
Page 1
cutting, fracturing or hammering. Non -friable sources of asbestos do not typically pose a
significant exposure risk if they remain in good condition and are not disturbed. During
renovation or demolition activities, non -friable sources may become friable and thus may pose an
exposure risk.
The PLM method is the most commonly used method to analyze building materials for the
presence of asbestos. This method utilizes the optical properties of minerals to identify the
selected constituent. The use of this method enables identification of the type and the
percentage of asbestos in a given sample. The detection limit of the PLM method for asbestos
identification is typically one percent (1%) asbestos. The Colorado Department of Public Health
and Environment regulations define an ACM as any material which contains greater than one
percent (1 %) asbestos.
LEAD-BASED PAINT
A lead-based paint inspection is a surface -by -surface investigation to determine the presence of
lead-based paint and the provision of a report explaining the results of the investigation. Partner
utilized a Niton XLP-300A (serial no. 94979) X -Ray Fluorescence (XRF) analyzer to conduct this
survey. The XRF uses a Cadmium 109 (Cd) isotope radioactive source to 'excite' the atomic
structure of painted surfaces. Once 'excited, lead (Pb) atoms emit unique x-ray emission. The
radiation detector within the XRF then translates these x-rays into a quantitative measure of lead
concentration. If present, the XRF will determine the amount of lead in paint with a 95%
confidence level. The lead concentrations are reported in milligrams per square centimeter
(mg/cmc).
Measurements were taken at locations representative of all painted or varnished surfaces for each
different testing combination in the areas inspected. In order to obtain a reading, the XRF
analyzer is placed with the face of the instrument flush against the surface to be tested. Itis then
held in place for the duration of the sample, approximately 4 to 16 source seconds, or until the
measurement has reached the acceptable range of accuracy. The sampling time is dependent on
the age of the radioactive source inside the XRF.
XRF analysis yields the total lead content of a painted surface, and not distinguishing between
individual concentrations of painted layers. The XRF was calibrated with a National Institute of
Standards and Testing (NIST) calibration surface priorto and post analysis of painted surfaces.
The subject property's orientation is described using HUD's recommended guidelines, assigning
the letters A, B, C and D to each side. Side A corresponds to the main entrance of each building.
The remaining side identifications are assigned in a clock -wise manner. Each tested component
location is identified using the building's assigned letter as a reference point.
The Colorado Department of Public Health and Environment Regulation 19 defines LBP as paint
or other surface coating that contains any amount of lead equal to or in excess of 1.0 mg/cmc or
more than 0.5% by weight.
Asbestos and Lead-based Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page 2
Lead-based paint may be present in buildings constructed in 1978 and earlier. In general, there
are many other building materials which can contain lead in the average building. When
conducting construction or demolition activities which disturb lead in any amount or create an
exposure to workers, the employer is required to provide worker protection and conduct
exposure assessments. Employers should consult Federal OSHA Regulations at 29 CFR 1926.62,
"Lead in Construction" standards for complete requirements prior to construction or demolition
activities. Notification must be given to all other contractors at the work site prior to the start of
activities that may create a lead hazard. Characterization and disposal of lead -containing waste
materials (LCWMs) must comply with federal, state and local authorities. Contractors must
maintain current licenses as required by applicable state or local jurisdictions for the removal,
transport, disposal of LCWMs, or other regulated lead-based paint activities.
Asbestos and Lead- based Paint Survey PARTNER
Project19-258685.2
Octoberr 2, 2, 2019
Page
2.0 ASBESTOS/LEAD SURVEY
2.1 Visual Inspection
During the course of the property visit, John Burnside, performed a review of accessible areas of
the subject building for the presence of suspect ACM and LBP. The purpose of this assessment is
for renovation purposes only, therefore, additional suspect ACM and/or LBP could be present. No
renovation scope was provided to Partner prior to conducting the survey.
Partner did not attempt to disassemble mechanical equipment, open pipe chases, or assess
materials within wall voids. Regardless of the thoroughness of a survey, the possibility exists that
some areas containing ACM and/or LBP were not identified, inaccessible, or different from those
materials at specific locations.
Caesar's Square Apartments consists of five apartment buildings constructed of brick and
concrete. 9235 & 9265 West 481h Avenue have exterior metal stairs for external access to each
apartment unit. 9295, 9325 and 9355 West 48th Avenue have interior hallways and stairs to allow
access to each apartment unit. Buildings 9235, 9265 and 9295 had heavy textured ceilings
(popcorn) and Buildings 9325 and 9355 had ceilings with finishes similar to the sprayed texture
present on the drywall walls. Floors were typically carpet or vinyl.
ASBESTOS
Suspect asbestos -containing materials observed at the time of the inspection were sampled and
analyzed for asbestos content. The survey also established whether any of the substrates
sampled could be considered friable and/or significantly damaged or capable of immediate
worker exposure.
LEAD-BASED PAINT— XRF TESTING PROTOCOL
During the course of the property visit, John Burnside, performed a review of accessible areas of
the subject building for the presence of suspect LBP. The painted/finished surfaces containing
suspect LBP were analyzed and the data was recorded using an XRF.
2.2 Testing Results
ASBESTOS
Twenty-six (26) units were accessed at the site to evaluate the presence of suspect ACM. A total of
eighty (80) bulk samples of suspect ACM were collected for analysis. The samples were grouped
into homogeneous categories, assigned individual sample numbers, sealed in plastic bags, and
transported under proper chain -of -custody documentation to LA Testing. LA Testing is
accredited by the National Voluntary Laboratory Accreditation Program (NVLAP No. 200232-0) for
the analysis of asbestos bulk samples. Refer to Appendix A for analytical data. The analytical
results are summarized in the table below:
Asbestos and Lead-based Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page4
Bulk Sample Analytical Results for Analysis of Asbestos Content
Sample No. Location Description Asbestos
Content
1C01 Unit 9235- Office Ceiling texture 5% Chrysotile
1CO2
Unit 9235- Office
Ceiling texture
5% Chrysotile
1CO3
Unit 9235-06
Ceiling texture
5% Chrysotile
1C04
Unit 9235-19
Ceiling texture
5% Chrysotile
1C05
Unit 9235-19
Ceiling texture
5% Chrysotile
1C06
Unit 9235-20
Ceiling texture
5% Chrysotile
1C07
Unit 9235-11
Ceiling texture
5% Chrysotile
1W01
Unit 9235 -Office
Drywall system w/ texture
2% Chrysotile
1W02
Unit 9235 -Office
Drywall system w/ texture
2% Chrysotile
1W03
Unit 9235-06
Drywall system w/ texture
2% Chrysotile
1W04
Unit 9235 -Laundry
Drywall system w/ texture
ND
1W05
Unit 9235-19
Drywall system w/ texture
2% Chrysotile
1W06
Unit 9235-20
Drywall system w/ texture
2% Chrysotile
1W07
Unit 9235-11
Drywall system w/ texture
2% Chrysotile
1WVBA01
Unit 9235 -Office
Vinyl base adhesive
ND
1WVBA02
Unit 9235-06
Vinyl base adhesive
ND
1F01
Unit 9235 -Office
Vinyl flooring
ND
1F02
Unit 9235-06
Vinyl flooring
ND
1F03
Unit 9235 -Laundry
Vinyl flooring
2% Chrysotile
1F04
Unit 9235-19
Vinyl flooring
ND
2C01
Unit 9265-12
Ceiling texture
5% Chrysotile
2CO2
Unit 9265-12
Ceiling texture
5% Chrysotile
2CO3
Unit 9265-01
Ceiling texture
5% Chrysotile
2C04
Unit 9265-04
Ceiling texture
5% Chrysotile
Asbestos and Lead-based Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page 5
Sample No. Location Description
Content
2C05 Unit 9265-06 Ceiling texture 5% Chrysotile
2C06
Unit 9265-18
Ceiling texture
5% Chrysotile
2C07
Unit 9265-13
Ceiling texture
5% Chrysotile
2W01
Unit 9265-12
Drywall system w/ texture
2% Chrysotile
2W02
Unit 9265-12
Drywall system w/ texture
2% Chrysotile
2W03
Unit 9265-01
Drywall system w/ texture
2% Chrysotile
2W04
Unit 9265-04
Drywall system w/ texture
2% Chrysotile
2W05
Unit 9265-06
Drywall system w/ texture
2% Chrysotile
2W06
Unit 9265 -Laundry
Drywall system w/ texture
2% Chrysotile
2W07
Unit 9265-13
Drywall system w/ texture
2% Chrysotile
2%Chrysotile —
2WVBA01
Unit 9265-12
Vinyl base adhesive
Note 1
2WVBA02
Unit 9265-04
Vinyl base adhesive
ND
2F01
Unit 9265-12
Vinyl flooring
ND
2F02
Unit 9265-01
Vinyl flooring
ND
2F03
Unit 9265-04
Vinyl flooring
ND
3C01
Unit 9295-103
Ceiling texture
5% Chrysotile
3CO2
Unit 9295-107
Ceiling texture
5% Chrysotile
3CO3
Unit 9295-101
Ceiling texture
5% Chrysotile
Unit 92951" floor SE
5% Chrysotile
3C04
Ceiling texture
Hall
3C05
Unit 9295-102
Ceiling texture
5% Chrysotile
3C06
Unit 9295-205
Ceiling texture
5% Chrysotile
3C07
Unit 9295-205
Ceiling texture
5% Chrysotile
3W01
Unit 9295-103
Drywa II system w/texture
2% Chrysotile
3W02
Unit 9295-107
Drywall system w/ texture
2% Chrysotile
3W03
Unit 9295-101
Drywall system w/ texture
2% Chrysotile
Asbestos Nand -258685.2 Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page 6
Sample No. Location Description
Content
3W04 Unit 9295 -Laundry Drywall system w/ texture 2% Chrysotile
Unit 92951" floor SE
2% Chrysotile
3W05
Drywa II system w/texture
Hall
3W06
Unit 9295-102
Drywall system w/ texture
2% Chrysotile
3W07
Unit 9295-205
Drywall system w/ texture
2% Chrysotile
2%Chrysotile —
3WVBA01
Unit 9295-103
Vinyl base adhesive
Note 1
3WVBA02
Unit 9295-101
Vinyl base adhesive
ND
3F01
Unit 9295-101
Vinyl flooring
ND
3F02
Unit 9295-101
Vinyl flooring
ND
4W01
Unit 9325-08
Drywall system w/ texture
2% Chrysotile
4W02
Unit 9325-08
Drywall system w/ texture
2% Chrysotile
4W03
Unit 9325-17
Drywall system w/ texture
2% Chrysotile
4W04
Unit 9325-17
Drywall system w/ texture
2% Chrysotile
4W05
Unit 9325-18
Drywall system w/ texture
2% Chrysotile
4W06
Unit 9325-20
Drywall system w/ texture
2% Chrysotile
4W07
Unit 9325-12
Drywall system w/ texture
2% Chrysotile
4WVBA01
Unit 9325-08
Vinyl base adhesive
ND
4WVBA02
Unit 9325-17
Vinyl base adhesive
ND
4F01
Unit 9325-08
Vinyl flooring
ND
4F02
Unit 9325-17
Vinyl flooring
ND
4F03
Unit 9325-18
Vinyl flooring
ND
SW01
Unit 9355-10
Drywa II system w/texture
2% Chrysotile
SW02
Unit 9355-10
Drywall system w/ texture
2% Chrysotile
SW03
Unit 9355-03
Drywall system w/ texture
2% Chrysotile
SW04
Unit 9355-06
Drywall system w/ texture
2% Chrysotile
SWO5
Unit 9355-21
Drywall system w/ texture
2% Chrysotile
Asbestos Nand -258685.2 Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page 7
Sample No. Location Description
Content
SW06 Unit 9355-21 Drywall system w/ texture 2% Chrysotile
SW07
Unit 9355-13
Drywall system w/ texture
2% Chrysotile
2%Chrysotile —
SWVBA01
Unit 9355-10
Vinyl base adhesive
Note 1
SWVBA02
Unit 9355-03
Vinyl base adhesive
ND
SF01
Unit 9355-10
Vinyl flooring
ND
SF02
Unit 9355-03
Vinyl flooring
ND
Note 1 — Some of the vinyl base adhesive samples had drywall texture included with the
sample as drywall texture was adhered to the adhesive and came off with the vinyl base
adhesive when sampled.
Documentation of the laboratory results should be retained as a reference for future renovation/
demolition activities.
LEAD-BASED PAINT
Twenty-six (26) units were accessed at the site to evaluate the presence of suspect LBP. A
representative number of interior/exterior painted surfaces/components were tested for LBP at
the subject properties.
A total of 448 XRF readings (including 9 calibration readings) were collected throughout the
subject property. No readings indicated a lead content greater than 1.0 or greater mg/cmc, which
is the current regulatory threshold for the requirement of lead -safe work practices in the
Colorado, as assessed using an XRF instrument. Additional readings confirmed detectable levels
of lead in paint (less than 1.0 mg/cmc). Please see Appendix E for Suspect Lead -Based Paint
Inspection Results.
Analytical Results (LBP)
No lead-based paint was detected during the sampling of the apartment units. The XRF results
are available in Appendix E.
LBP is defined under the US Department of Housing and Urban Development (HUD) and the
Environmental Protection Agency (EPA) as paint or other surface coating with lead content equal
to or greater than 1.0 mgl of surface area by XRF or 0.5% by weight (5,000 parts per million
(ppm)) by paint chip analysis.
Asbestos and Lead-based Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page 8
3.0 CONCLUSION
ASBESTOS
The following building materials were confirmed to contain asbestos
• Heavy textured drywall ceilings in Building 1 (9235), Building 2 (9265) and Building 3
(9295)
• Drywall wall systems in all buildings
• Drywall ceilings in Building 4 (9325) and Building 5 (9355)
• Vinyl flooring in the laundry rooms
• Drywall texture attached to the vinyl base adhesive
An Operations and Maintenance program should be prepared to provide for the proper training
and appropriate work practices requires for employees to replace ceiling fixtures during current
rehabilitation plans. A comprehensive and thorough inspection is required for a major renovation
or demolition project in accordance with the EPA NESHAP (Asbestos). The roofs) appeared to be
in good overall condition and were not sampled as a part of the survey.
The EPA recommends that all ACM be removed by a certified asbestos contractor prior to any
renovation or demolition activities that may impact the material. In the absence of planned
renovation/demolition activities, the EPA recommends that ACMs be managed in-place whenever
asbestos is identified in a building. Any damaged asbestos materials should be removed,
repaired, encapsulated, or enclosed. Asbestos materials that are not damaged may be managed
in place in accordance with a written Operations and Maintenance Program.
Federal, state and local laws require building owners and/or their representatives, prior to any
demolition and/or renovation operations which may disturb any asbestos -containing materials in
their buildings, to meet the following requirements:
• Notifications,
• Remova l tech n iques(such as wetti ng)for asbestos-contai n i ng materials,
• Clean-up procedures,
• Waste storage and disposal requirements.
The potential exists for additional suspect ACM to be exposed during demolition and/or
renovation activities. Such materials should be sampled and analyzed for asbestos content prior
to any renovation and/or demolition activities that could impactthese materials.
LEAD-BASED PAINT
During the inspection LBP was not identified at the subject building. Some of the samples
contained detectable concentrations of lead below the threshold for LBP. Please note that OSHA
does not recognize XRF results as a determination that lead is not present in surface coatings.
Work activities impacting lead containing coatings pose a potential exposure risk for workers
and/or building occupants. Workers trained in proper safety and respiratory techniques should
Asbestos and Lead-based Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page
perform renovation activities that may impact the lead containing coatings. All construction work
where an employee may be occupationally exposed to lead must comply with OSHA
requirements set forth in 29 CFR 1926.62. This regulation requires initial employee exposure
monitoring to evaluate worker exposure during work that disturbs lead -containing materials (lead
present in detectable levels). Partner recommends that representative coated surfaces be
sampled via the paint chip method and analyzed via flame atomic absorption.
Waste items generated during an abatement or demolition project should be properly sampled
and profiled to determine the final disposition of the waste.
The potential exists for additional suspect lead -containing materials to be exposed during
demolition and/or renovation activities. Such materials should be sampled and analyzed for lead
content priorto any renovation and/or demolition activities that could impact these materials.
Asbestos and Lead-based Paint Survey PARTNER
Project No. 19-258685.2
October 2, 2019
Page 10
4.0 LIMITATIONS
Partner subcontracted with Eurofins — EMLab P&K to perform the asbestos analysis. No
warranties expressed or implied, are made by Partner or its subcontractor Eurofins — EMLab P&K,
or their employees as to the use of any information, apparatus, product or process disclosed in
this report Every reasonable effort has been made to assure correctness. If an Asbestos and/or
Lead Abatement Contractor or other Demolition/Construction Contractor is employed, such
contractor should bring any discrepancies found in this report as it relates to current site
conditions or newly discovered site conditions to the immediate attention of Partner.
State-of-the-art practices have been employed to perform this asbestos and lead survey. The
scope of this evaluation was severely limited to areas which were considered reasonably
accessible (i.e., less than 15 feet from the floor), or within range of a visual inspection through
reasonable means. No demolition or product research was performed in attempts to reveal
material compositions. The services consist of professional opinions and recommendations made
in accordance with generally accepted engineering principles/practices. These services are
designed to provide an analytical tool to assist the client. Partner and its subcontractor Eurofins
— EMLab P&K and their employees/representatives bear no responsibility for the actual condition
of the structure or safety of this site pertaining to asbestos and/or lead contamination regardless
of the actions taken by the survey team or the client.
Any quantities of ACM/LBP listed are estimates only and not meant to be used to solicit
abatement quotations. These quantities should be confirmed by abatement contractors prior to
submitting bids for abatement.
Asbestos and Lead-based Paint Survey PARTNER
Project19-258685.2
Octoberr 2, 2, 2019
Page 11
5.0 SIGNATURES OF PROFESSIONALS
Partner has performed a limited asbestos and LBP survey on the property at 9235-9355 West 48`h
Avenue, Wheat Ridge, Colorado 80033 in general conformance with the scope and limitations of the
protocol and the limitations stated earlier in this report Exceptions to or deletions from this protocol
are discussed earlier in this report.
Prepared By:
Partner Engineering and Science, Inc.
John Burnside
Colorado Asbestos Building Inspector#21520
Colorado Lead -Based Paint Risk Assessor 11786
?effre�Lger Jr.
Project Manager — Industrial Hygiene Services
Asbestos and Lead-based Paint Survey PARTNER
Project19-258685.2
Octoberr 2, 2, 2019
Page 12
APPENDIX A: LABORATORY ANALYSIS AND CHAIN OF CUSTODY
PARTNER
CHAIN OF CUSTODY WEASHEn I Ind off. Jr. Cure LIS
whow. EMLaEPK. wm en REQUESTED SERVICES f�aohae
m II NJ Cast bull n lnot 871-19841 � E
Pli What reuoxn Does Pnrcmu�AZ 85027 -Mass 651 4k tltltl Roberts
S San FaA2e CAMi rowk
OVISE Of Ste 203 S.So, FUri CA 9400 - (656)fiSeE653
Panner EntmeeMg BSagncs all Acd 9 Thei 1544 ALI did SWI, 160, RmevAu, CA H 5E61
rim. Me,, wAmg so,mn le"N'n, 2 day TAT requested
mnmlo 19-251
iolap Daae. wheal Ridge Co
a.6WC DM fl TIM, slang 09: e0
D NATO,
STEP
xQ.,uatl
s0
wH.w
. COLLINS(DEFAULT)
Eo,in„a D,r
same fivamea Day xu ,
x°llday
Ruenm rerelved after 2Pm or
On meexendi m1i be c°n9dere
rved the nel Imma qday
Pkeee Wont ua In advance or
whakend analyse creme.
smq.lo
peanpnm
Se,xaner TAT
Type (AREAS
p1
v um✓l
xmEs
SW so
Sir/
ealowl 1
(as
1Tune of Tame, RH al
avoe
u9web
/Ca/ Ce4c/uc re..✓f(
D
2
DA4
By "i W this
�Go3
loft
roue bound IS the aenoml el one, 11l,dolr wmmarms mml
v a
/CO(
C°er she 12002200 SOLVE Phe
/LOS
/�q
n�.,m,m n.r,d
L. IAl I.„.I.11ahn
/La 6
/co>
✓ALL CO.ae/p✓MD
/uif
yea✓OL
ST
T
D -
°1
Jabn BumeW
912712019019 9 W
:
mer
SW so
Sir/
r
avoe
u9web
By "i W this
Chain of Custody
loft
roue bound IS the aenoml el one, 11l,dolr wmmarms mml
v a
C°er she 12002200 SOLVE Phe
/�q
n�.,m,m n.r,d
L. IAl I.„.I.11ahn
CHAIN OF CUSTODY WETTHEN FW mir SM. Why, Code
roarer .EMLabPK.c[Im Noun REQUESTED&ERVII Neva,)
MrXOM1 NJ Was Lurcrin Drive
BAR,DrysMPM1YNoZ NJ lial0 100051-Jel 11 PU Nov _ -
Pulassix el
Frimo 501Weal Xn0ven 0llve.PMann, P205@) '10001851de01)
6000SF fv)CA re
SnanmeQ are 303, s. sen Franuam. CP 9<OBO ' 1&661000609
Planar Enpineering &Stroll, 11, Am p 1564D 1544 drove Road Sure 180, Rival So95661
mm. Samurai Suisse rmamne 2 day TAT requested
oia ID. u2sal
al
StradJQDEEAULTI
Rushes nadeve0 after darn or
m U
d
Joel Dam.
wtaRAN,
NO -Neq
Ouain„a Day
vseason0l will be CoConsulOei
N
Q Q
pliq
ecelved lbe nod business day,
f
do
End Can 0009
od
Dale S Time. SISSON 0900
ED -Sam,
Bay,eaa Day Ruan
Please aled us In ssbaW a of
Jcold
UNJ
Ni
PD :
VON
w.
wea
edend napais needs.
o
o e”
N m
_
p
Seplae
m
[Insulation
TressNavy,
vdumdPm
NOTES
n
a e
ffi
Ieabrvl )
Pe
(Tri Rally TamP, All
a
at
a
/WO
�,E/q�L orooa✓✓D
S Tg1y
//vO�
y
/✓9A0/
V✓✓c 9affjr Avii
/✓9
/o/ S,
% ✓c rcOOR,✓S
IY0IWf�,I�irVP�
/ /W
0022602263/63
/vi
/fel
LE�t�✓f %Er(n
za-d,
Zcoa
�/
1fOL
sT-Non,Raper a -ia erSIR SO soul L
S Bu
p, D Dan John armade 971 Pyy`��
No -
By morsern0rule Chun of Cliltiody. g... 1, Meouno JV To Terms end ¢mmsa
mns l loon al wm'embopeMml
your MOnpy00M G 20T? SOTS P1WO Psx
// U, amu., IRS, vn in, uurm Paovmu. om
CHAIN OF CUSTODY
WWw.EMLabPKcom BEwesreo sEBvmEs (v eoxe.l
m.rbn rvi 8000 L"<mnD,we East Sued a M.ntonX, OeooB r0661 e7t-,day) Di
e,SKnudsen DPenX. Az 85027 (800)65,48071
SSam F...m sales(ineb
d, CA Make
SOUP SAmlme At Ste 20A S San fivnmseo. CA 9000 ' Iaft 880E69
Paul, Engine eMpfl suenm ln[- root tlS05el ev o T80 Roseville
Mal New Cause sPe�una
a,a,ana 2 day TAT requested
put l0. 19 AN6053
11 SrO.@zma,a
REFA0T)
Nuaees recewea after arm or
d
Ppae Seed
Wheat Norge, CO
ND
NextBusiness Day
Onweekends, will Ce conedere0
w
Sampling
eat nets us ass eav_
s
o
Code : Way Date Time . sI S 09: 00
SID
Baine 8.11111, Oay Rase
Please elan ae In aeoeRed of
U
u
WN
W Y
w"kene able $,a nesse.
_
A
BiY Ple,iar
BBE
IT
O
S��Ple lO
geoeprbn
q
(oboe
Xol Marta
X07E4
n
ti_
(Below(
1
(as
Rine oldav, ism s. RR. at,
O
a umbel
sit
f f
Zm5
CAll u•Af Y£x��e'
r'j 2PAY
ZGO L
RCO �
I
Zwoi
L(/,ICG Cn./i"Ki
Zmoal
Z✓O�
I
I
0 02 2 63 16
002265FA,
3
takZAeylgs
A'/(J
I.
2Ve
V,wrat BesF All day
,
ST srobµm S rape o. ,bnEe,.de anawrl7:a0 1
sW-swao so"se,l
P od
PNo,Palms Wall 00 -Arps.
BY Sol by Cham o, Call 0, a are, to be hound by the linins Onocondrold At fent mv
I wemlebok mmam
ue e,ml
Oersot 0300b20e9 EMMb p6µ
5/7 un..o, In 1w,4o,..,.,„. n a,ew.
CHAIN OF CUSTODY
vrvrvu.EMLabi mm
Sol ,NR 00 NJ M53 1abal671-real
rvc Pr 1501 boostnSo rte Cane nPnnenu. AS 66097 -Mol 65116021
Pi
San France"". e
6000 Snor6ne C1 61e903, s. San Fnnmcr, On ACRES - mall AM6 653
Pe M er Eeni 6Sci lnn-Am 93MAS 1 are Eureka Read
roarevily, CA 96661
Jim Kamm Willi" sel ln,library 2day TAT requested
Sol ID
Domil enTyq
IB•Inwl
amore
VoIwW
as
warImbean
N
acme If wy.*eme, PR, Viol
=Fo{
Vial FKoo.o��G
ae 90-5"0
2! Poll
ZFvl
�J \i
1p
L
ZFOD
a-Du6t
2{0<
No
ISM-Picabla War
yTGo /
Gfe</✓fI fCK/1146
6yeuom 11,191Me
Cnam of Ccmy.
602
3
o<
Dopygm C p00]-3009 Sol V6x
i
F�7
aL
."...m.A a
Op
REQUESTED SERVICES IJ aenel
9n
spentPotable
uum1
John Bum•Ida 911).00
ae 90-5"0
�J \i
L
water ae,
a-Du6t
No
ISM-Picabla War
OWOlner
6yeuom 11,191Me
Cnam of Ccmy.
me, as,, to be bi by In, term, an0ian eel loch at wwwmla
.eopt cpnNnms Nor
Dopygm C p00]-3009 Sol V6x
F�7
."...m.A a
I in n,,.mn
CHAIN OF CUSTODY I WEATHER
WWon NJ board
K-nom Hi
OVESTEDBaavicE9 N6°..•I
Po Lincoln wEast 6NbPRound b NJ06655 I isLabol rp D855
broadly AS SO Waal Mnuaeen Dlrve, Plwem.,R05@1'16W16E1<BOb MWemie
CA Hery :7
W00 6nonine C161a 30], 6. Ben Frenorom CA 94W Inc318086659 _
rer Eng rnenryou of Bmnoe illAll016543 1 Sw flout, Road Suite 100 Bmevin,. CR 95661
Road wear 'epaauunnhorled, 2 day TAT requested
Roieu Is 1925058E 2
pgld Es", wheal Rlf9ec
Sampling
ZIP Clyde 80033 mu 8mme: 9,27119 W'. 66
Oel
u_w
STIR
No-Nenlisn
SD.
WN
Bl.nmNIOEFAV5T1
sDzv
Esme Bvsmeaaoay Bam
rHa
Rushes renewed after zpm or
on wreki vellbe Randalla
receivedt oen buamass aay.
Pleeee 6letl us in vi of
'weekend Sol sional
F
JPC
u
M
o
u
BampleTATy
on,
o
y
B.npro M
p.enpllo^
hw
tAs
vmu
NOTES
eewm
I
mabro
IT.namd, Tamp, IN ekl
FmI�
app
a
f
3 Zayi
v..d
g
ZPAY
O3
&0
002263763
05
OL
i
yon
3venor. v,,, v[
d
qViabRost.
3Fa/ Vi✓rte
<ou,✓f
F01
V
P zearodal
STSporeTrap• e D -C°el John Myraloe 9/P¢919
1]90
BWBury °h 6C-6oJ
-a•er
BP None sok Was OC1Mr:
By Whood,19 the Chain ofCvelWy,you agree lode bound by the ells and mnJAlons eel bno at way, emlaopkcon naav nuns
Copyapbl W 200E Jjq�o9 Chirac, Phi
CHAIN OF CUSTODY
www. EMLII tole @ REQUESTED SERVICES (Uah..q
filliell NJ so able Di smi A Menson. NJ 08053 usi 571195p
K(y
Phimalli 1501 what Nwesen Choy. Pnn.nN, As 85027 -Isom 551-nmzl
a
ab,CA
WBB ShohimCt Sle ]O0. S San Fmntlw CA 9W00 - 10%10009050
Inc Acct 0 M ly ureaa W
Iy, Be 951
scemeunmmmnny Sl
day TAT requested
'ro•[1 to ID-zs¢saE]
STO.
Standard(DEFAULT)
Rushes rec¢IVM after 2pm or
ta
v9¢h¢Otls. wlll be tOnsltbrpy
a
mwm Beee.:
ween Pop eouD.
s.mpunp
u•n e11a1nye °ay
e�mee me ren h0hm¢aa ear.
f
-�
o
IF CORE ti
Dale S nme 9CE190900
SD -Came Business Oay Ruin
PI¢¢¢al¢11 u91n etiv¢n[¢OI
U
is
be
_
weehenG enalVsls neetic
ty
t
V NumMr.
wN
w eeand Houdey
b
_
_
d
SmpM
vnwlasram
NOTES
rdRD
a
BemgelD
penlptlan
Type (curve
(sae urear. temp. rex. lettJay
(Below) 1
a ¢ eIS
Q
2.
J
IIPC,O
//AG[ so eD
N Ippy,
J7
m➢IMI�WIN�IIII'��I61V'
JOCA
�L
oo22e37e3
O1
211
di'eb/
Vi 6.eri /JOOfSa✓f
at
L
fFo/
V,vvc F.vu..�a
y Ono—
w VCporeirap. T. rupee D. un Jonn Bilrzoten
Swab 50 -Sou
othabu
No, PILlus Vital 0 Other
By ynemul p this Cham o(Dusady you aymto be Lound by the See ARE mrshans authors s iveavhmlaepe.vnmhermh The
Copyrlphl m 2002-x009 EML. PON
G/-7 a..aanls ni. aaam e..1a,. dah
CHAIN OF CUSTODY
wWw EMLfr com
Bi
e St One A Notion, N 66l llet
bn. NJ 3020Imestn udeE 1888 6
me PZ 1501 West Knudsen ems, PhOr PZ 8589 5)BOOj 651 Mewl
A SO' Ful CA
68085nanineP An J03. 5 Sen inncem. CP Al ' (866)688.665)
Pauper EnBlneal d 5wnce Inc- Acct 036543
120."ten Willing
19-2586852
80833 Card Tlmx L9/1909 OD
SOmpb ID I Cnor"i
ne 180, RouWIb, CA 93661
fail Inmeelanx.2 day TAT requested
NO - and Beane.. Day modencyleved Me e
ED- Rame Deamese Davmtm I+lesseelee�s
}�A?5
/.vi.Icc
c fes,.. -o i4 2DM
ob
oS
OL
07
SVBAO/
1/iNYc
9ASf iCgfiS�4F
Fe/oL
Viu vc
l�l//
Fob<iuq
S Fva
JI
NOTES
(Time Of day, Temp, RK el
REQUESTED SERVICES (in'BCA")
AT. Spore nap. tape u -es Jpnn Bdu,nker W27RI1911 SO
SaoSend Sofail
It Paul water 8 Bul
aR- Non.Peleme wale 0. Cither
By submitting this Chain 0 Custody. hill 19111 Ic 4 pound by the term. and COrdenl aelmy an f,s Annual wait dill
pYnl9n102002-2009 Eirt V6K
7�17 e,..2a„e ae.i.em,tman,ta.a
tiff eurofins
i EMLab P&K
Report for:
Karen Willing
Partner Engineering & Science Inc. NorCal
1544 Eureka Road, Suite 180
Roseville, CA 95661
Regarding: Project: 19-258685.2; Wheat Ridge, CO
EML ID: 2263763
Approved by:
Approved Signatory
Noah Lazarte
Dates of Analysis:
Asbestos PLM: 09-30-2019 and 10-01-2019
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM -AS -S-1267)
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The
results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with
estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1 % asbestos
concentration can be provided when requested.
Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or
recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result
of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for
the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential
damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been
advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the
Test Results exceed the amount paid to the Company by the client therefor.
EMLab P&K, LLC EMLab ID: 2263763, Page 1 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 1C01, Ceiling Texture
Total Samples Submitted: 81
Total Samples Analyzed: 80
Total Samples with Layer Asbestos Content> 1%: 59
Lab ID -Version$: 10765072-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: ICO2, Ceiling Texture
Lab ID -Version$: 10765073-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: IC03, Ceiling Texture
Lab ID -Version$: 10765074-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: IC04, Ceiling Texture
Lab ID -Version$: 10765075-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sam IeCom ositeHomo enei
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 2 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: IC05, Ceiling Texture
Lab ID -Version$: 10765076-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: IC06, Ceiling Texture
Lab ID -Version$: 10765077-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: IC07, Ceiling Texture
Lab ID -Version$: 10765078-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 1W01, Wall Compound
Lab ID -Version$: 10765079-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 3 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: IW02, Wall Compound
Lab ID -Version$: 10765080-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: IW03, Wall Compound
Lab ID -Version$: 10765081-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: IW04, Wall Compound
Lab ID -Version$: 10765082-1
Sample Layers
Asbestos Content
Beige Floor Tile
ND
Multicolored Mastic
ND
Sample Composite Homogeneity:
Poor
Location: IW05, Wall Compound
Lab ID -Version$: 10765083-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 4 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: IW06, Wall Compound
Lab ID -Version$: 10765084-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: IW07, Wall Compound
Lab ID -Version$: 10765085-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 1VBA01, Vinyl Base Adhesive
Lab ID -Version$: 10765086-1
Sample Layers
Asbestos Content
White Baseboard
ND
Brown Mastic
ND
Sample Composite Homogeneity:
Moderate
Location: IVBA02, Vinyl Base Adhesive
Lab ID -Version$: 10765087-1
Sample Layers
Asbestos Content
Gray Baseboard
ND
Cream Mastic
ND
Sample Composite Homogeneity:
Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 5 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 1F01, Vinyl Flooring
Lab ID -Version$: 10765088-1
Sample Layers
Asbestos Content
Brown Sheet Flooring
ND
Sample Composite Homogeneity:
Good
Location: 1F02, Vinyl Flooring
Lab ID -Version$: 10765089-1
Sample Layers
Asbestos Content
Gray Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Composite Non -Asbestos Content:
20% Cellulose
10% Glass Fibers
Sample ComositeHomogeneity:
Moderate
Location: 1F03, Vinyl Flooring
Lab ID -Version$: 10765090-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 1F04, Vinyl Flooring
Lab ID -Version$: 10765091-1
Sample Layers
Asbestos Content
Gray Sheet Flooring with Fibrous Backing
ND
Composite Non -Asbestos Content:
20% Cellulose
10% Glass Fibers
Sample Composite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 6 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 2C01, Ceiling Texture
Lab ID -Version$: 10765092-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2CO2, Ceiling Texture
Lab ID -Version$: 10765093-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 2CO3, Ceiling Texture
Lab ID -Version$: 10765094-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2C04, Ceiling Texture
Lab ID -Version$: 10765095-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 7 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 2C05, Ceiling Texture
Lab ID -Version$: 10765096-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2C06, Ceiling Texture
Lab ID -Version$: 10765097-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 2C07, Ceiling Texture
Lab ID -Version$: 10765098-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2W01, Wall Compound
Lab ID -Version$: 10765099-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 8 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 2W02, Wall Compound
Lab ID -Version$: 10765100-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2W03, Wall Compound
Lab ID -Version$: 10765101-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 2W04, Wall Compound
Lab ID -Version$: 10765102-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2W05, Wall Compound
Lab ID -Version$: 10765103-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 9 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 2W06, Wall Compound
Lab ID -Version$: 10765104-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 2W07, Wall Compound
Lab ID -Version$: 10765105-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 2VBA01, Vinyl Base Adhesive
Lab ID -Version$: 10765106-1
Sample Layers
Asbestos Content
Beige Baseboard
ND
Cream Mastic
ND
Off -White Leveling Compound
2% Chrysotile
Sample ComositeHomogeneity:
Poor
Location: 2VBA02, Vinyl Base Adhesive
Lab ID -Version$: 10765107-1
Sample Layers
Asbestos Content
Beige Baseboard
ND
Cream Mastic
ND
Sample Composite Homogeneity:
Moderate
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 10 of 21
EuroTms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 2F01, Vinyl Flooring
Lab ID -Version$: 10765108-1
Sample Layers
Asbestos Content
Beige Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Composite Non -Asbestos Content:
20% Cellulose
10% Glass Fibers
Sample Composite Homogeneity:
Moderate
Location: 2F02, Vinyl Flooring
Lab ID -Version$: 10765109-1
Sample Layers
Asbestos Content
Beige Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Composite Non -Asbestos Content:
20% Cellulose
10% Glass Fibers
Sample Composite Homogeneity:
Moderate
Location: 2F03, Vinyl Flooring
Lab ID -Version$: 10765110-1
Sample Layers
Asbestos Content
Brown Sheet Flooring
ND
Semi -Transparent Mastic
ND
Sample ComositeHomogeneity:
Moderate
Location: 3C01, Ceiling Texture
Lab ID -Version$: 10765112-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 11 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 3CO2, Ceiling Texture
Lab ID -Version$: 10765113-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3CO3, Ceiling Texture
Lab ID -Version$: 10765114-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 3C04, Ceiling Texture
Lab ID -Version$: 10765115-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3C05, Ceiling Texture
Lab ID -Version$: 10765116-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 12 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 3C06, Ceiling Texture
Lab ID -Version$: 10765117-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3C07, Ceiling Texture
Lab ID -Version$: 10765118-1
Sample Layers
Asbestos Content
White Ceiling Texture with Paint
5% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 3W01, Wall Compound
Lab ID -Version$: 10765119-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3W02, Wall Compound
Lab ID -Version$: 10765120-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 13 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 3W03, Wall Compound
Lab ID -Version$: 10765121-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3W04, Wall Compound
Lab ID -Version$: 10765122-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 3W05, Wall Compound
Lab ID -Version$: 10765123-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3W06, Wall Compound
Lab ID -Version$: 10765124-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 14 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 3W07, Wall Compound
Lab ID -Version$: 10765125-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 3VBA01, Vinyl Base Adhesive
Lab ID -Version$: 10765126-1
Sample Layers
Asbestos Content
Off -White Baseboard
ND
Cream Mastic
ND
Off -White Compound
2% Chrysotile
Sample ComositeHomogeneity:
Poor
Location: 3VBA02, Vinyl Base Adhesive
Lab ID -Version$: 10765127-1
Sample Layers
Asbestos Content
Beige Baseboard
ND
Cream Mastic
ND
Sample ComositeHomogeneity:
Poor
Location: 3F01, Vinyl Flooring
Lab ID -Version$: 10765128-1
Sample Layers
Asbestos Content
Brown Sheet Flooring
ND
Semi -Transparent Mastic
ND
Brown Wood
ND
Composite Non -Asbestos Content:
10% Cellulose
Sample ComositeHomogeneity:
Poor
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 15 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 3F02, Vinyl Flooring
Lab ID -Version$: 10765129-1
Sample Layers
Asbestos Content
Brown Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Beige Sheet Flooring with Fibrous Backing
ND
Composite Non -Asbestos Content:
30% Cellulose
10% Glass Fibers
Sample ComositeHomogeneity:
Poor
Location: 4W01, Wall Compound
Lab ID -Version$: 10765130-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 4W02, Wall Compound
Lab ID -Version$: 10765131-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 4W03, Wall Compound
Lab ID -Version$: 10765132-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 16 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 4W04, Wall Compound
Lab ID -Version$: 10765133-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 4W05, Wall Compound
Lab ID -Version$: 10765134-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 4W06, Wall Compound
Lab ID -Version$: 10765135-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 4W07, Wall Compound
Lab ID -Version$: 10765136-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 17 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 4VBA01, Vinyl Base Adhesive
Lab ID -Version$: 10765137-1
Sample Layers
Asbestos Content
Beige Baseboard
ND
Cream Mastic
ND
Sample Composite Homogeneity:
Moderate
Location: 4VBA02, Vinyl Base Adhesive
Lab ID -Version$: 10765138-1
Sample Layers
Asbestos Content
Gray Baseboard
ND
Cream Mastic
ND
Sample ComositeHomogeneity:
Moderate
Location: 4F01, Vinyl Flooring
Lab ID -Version$: 10765139-1
Sample Layers
Asbestos Content
Brown Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Beige Sheet Flooring with Fibrous Backing
ND
Composite Non -Asbestos Content:
30% Cellulose
10% Glass Fibers
Sample ComositeHomogeneity:
Poor
Location: 4F02, Vinyl Flooring
Lab ID -Version$: 10765140-1
Sample Layers
Asbestos Content
Brown Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Beige Sheet Flooring with Fibrous Backing
ND
Semi -Transparent Mastic
ND
Composite Non -Asbestos Content:
30% Cellulose
10% Glass Fibers
Sample ComositeHomo enei
Poor
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 18 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 4F03, Vinyl Flooring
Lab ID -Version$: 10765141-1
Sample Layers
Asbestos Content
Brown Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Composite Non -Asbestos Content:
20% Cellulose
10% Glass Fibers
Sample Composite Homogeneity:
Moderate
Location: 5W01, Wall Compound
Lab ID -Version$: 10765142-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 5W02, Wall Compound
Lab ID -Version$: 10765143-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 5W03, Wall Compound
Lab ID -Version$: 10765144-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of t urty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 19 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 5W04, Wall Compound
Lab ID -Version$: 10765145-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 5W05, Wall Compound
Lab ID -Version$: 10765146-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
Location: 5W06, Wall Compound
Lab ID -Version$: 10765147-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Composite Homogeneity:
Good
Location: 5W07, Wall Compound
Lab ID -Version$: 10765148-1
Sample Layers
Asbestos Content
Off -White Compound with Paint
2% Chrysotile
Sample Comosite Homogeneity:
Good
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater titan 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 20 of 21
Eurorms EMLab P&K
4955 Yarrow Street, Arvada, CO 80002
(800) 651-4802 Fax (623) 780-7695 www.emlab.com
Client: Partner Engineering & Science Inc. NorCal
C/O: Karen Willing Date of Receipt: 09-27-2019
Re: 19-258685.2; Wheat Ridge, CO Date of Report: 10-01-2019
ASBESTOS PLM REPORT
Location: 5VBA01, Vinyl Base Adhesive
Lab ID -Version$: 10765149-1
Sample Layers
Asbestos Content
Off -White Baseboard
ND
Cream Mastic
ND
Off -White Compound
2% Chrysotile
Sample Composite Homogeneity:
Poor
Location: 5VBA02, Vinyl Base Adhesive
Lab ID -Version$: 10765150-1
Sample Layers
Asbestos Content
Off -White Baseboard
ND
Cream Mastic
ND
Sample Composite Homogeneity:
Moderate
Location: 5F01, Vinyl Flooring
Lab ID -Version$: 10765151-1
Sample Layers
Asbestos Content
Tan Sheet Flooring with Fibrous Backing
ND
Yellow Mastic
ND
Composite Non -Asbestos Content:
20% Cellulose
10% Glass Fibers
Sample ComositeHomogeneity:
Moderate
Location: 5F02, Vinyl Flooring
Lab ID -Version$: 10765152-1
Sample Layers
Asbestos Content
Brown Sheet Flooring
ND
Semi -Transparent Mastic
ND
Gray Leveling Compound
ND
Yellow Mastic
ND
Sample ComositeHomogeneity:
Poor
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to
claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to
dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When
detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor file samples may contain large
amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection
limit and to aid in asbestos identification.
$ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
reflected by the value of "x".
EMLab P&K, LLC EMLab ID: 2263763, Page 21 of 21
No
Site
Results
P6C
1
Calibrate
Positive
1 mg/cm2
0.1
2
Calibrate
Positive
1 mg/cm2
0.1
3
Calibrate
Positive
1 mg/cm2
0.1
4
923506
Rm.
01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
5
923506
Rm.
01
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
6
923506
Rm.
01
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
7
923506
Rm.
01
C
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/cm2
0.02
S
923506
Rm.
02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
9
923506
Rm.
02
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
10
923506
Rm.
02
A
Wall
Radiator
Metal
White
Intact
Negative
0 mg/cm2
0.02
11
923506
Rm.
02
A
Door
Casing
Wood
Black
Intact
Negative
0.02 mg/cm2
0.04
12
923506
Rm.
02
A
Door
Wood
Stained
Intact
Negative
0.03 mg/cm2
0.05
13
923506
Rm.
03
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
14
923506
Rm.
03
A
Closet
Door
Wood
Brown
Intact
Negative
0 mg/cm2
0.02
15
923506
Rm.
03
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
16
923506
Rm.
04
D
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
17
923506
Rm.
04
D
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
16
923506
Rm.
04
D
Cabinet
Door
Wood
White
Intact
Negative
0 mg/cm2
0.02
19
923506
Rm.
05
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
20
923506
Rm.
05
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
21
923506
Rm.
05
B
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
22
923506
Rm.
05
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
23
923511
Rm.
01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
24
923511
Rm.
01
D
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
25
923511
Rm.
01
D
Wall
Radiator
Metal
White
Intact
Negative
0 mg/cm2
0.02
26
923511
Rm.
02
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
27
923511
Rm.
02
A
Door
Casing
Wood
Brown
Intact
Negative
0 mg/cm2
0.02
26
923511
Rm.
02
A
Door
Wood
Brown
Intact
Negative
0 mg/cm2
0.02
29
923511
Rm.
03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
30
923511
Rm.
03
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
31
923511
Rm.
03
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
32
923511
Rm.
04
C
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
33
923511
Rm.
04
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
34
923511
Rm.
05
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
35
923511
Rm.
05
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/cm2
0.02
36
923519
Rm.
01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
37
923519
Rm.
01
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
36
923519
Rm.
01
D
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
39
923519
Rm.
02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
40
923519
Rm.
02
D
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
41
923519
Rm.
03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
42
923519
Rm.
03
D
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
43
923519
Rm.
03
D
Wall
Radiator
Metal
White
Intact
Negative
0.02 mg/cm2
0.1
44
923519
Rm.
03
D
Door
Jamb
Wood
Brown
Intact
Negative
0.2 mg/cm2
0.22
45
923519
Rm.
03
D
Door
Wood
Brown
Intact
Negative
0 mg/cm2
0.02
46
923519
Rm.
04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
47
923519
Rm.
04
B
Wall
Drywall
White
Intact
Negative
0.05 mg/cm2
0.9
48
923519
Rm.
04
B
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
49 923520
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
50 923520
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
51 923520
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
52 923520
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0 mg/cm2
0.02
53 923520
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
54 923520
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
55923520
Rm. 02
D
Door
Jamb
Wood
White
Intact
Negative
0.03 mg/cm2
0.05
56 923520
Rm. 02
D
Door
Wood
White
Intact
Negative
0 mg/cm2
0.02
57 923520
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
56923520
Rm. 03
A
Door
Jamb
Wood
White
Intact
Negative
0.12 mg/cm2
0.22
59 923520
Rm. 03
A
Door
Wood
White
Intact
Negative
0 mg/cm2
0.02
60 923520
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
61 923520
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0.01 mg/cm2
0.06
62 923520
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
63 923520
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
64 9235 Laundry
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
65 9235 Laundry
Rm. 01
A
Wall
Drywall
Green
Intact
Negative
0 mg/cm2
0.02
66 9235 Laundry
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
67 9235 Laundry
Rm. 01
A
Door
Casing
Wood
Brown
Intact
Negative
0.01 mg/cm2
0.03
66 9235 Laundry
Rm. 01
A
Door
Wood
Brown
Intact
Negative
0.02 mg/cm2
0.06
69 9235 Office
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
70 9235 Office
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
71 9235 Office
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
72 9235 Office
Rm. 01
C
Cabinet
Door
Wood
Stained
Intact
Negative
0.03 mg/cm2
0.06
73 9235 Office
Rm. 01
A
Wall
Drywall
Tan
Intact
Negative
0 mg/cm2
0.02
74 9235 Office
Rm. 01
B
Wall
Drywall
Tan
Intact
Negative
0 mg/cm2
0.02
759235 Office
Rm. 01
B
Wall
Chair Rail
Wood
White
Intact
Negative
0Mg/cm2
0.02
76 9235 Office
Rm. 03
A
Wall
Drywall
Tan
Intact
Negative
0 mg/cm2
0.02
77 9235 Office
Rm. 03
D
Door
Jamb
Wood
Stained
Intact
Negative
0.13 mg/cm2
0.14
76 9235 Office
Rm. 03
D
Door
Wood
Stained
Intact
Negative
0 mg/cm2
0.02
79 9235 Office
Rm. 03
D
Closet
Door
Wood
White
Intact
Negative
0 mg/cm2
0.02
SO 9235 Office
Rm. 03
D
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
81 9235 Office
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
82 9235 Office
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
83 9235 Office
Rm. 04
D
Cabinet
Frame
Wood
Stained
Intact
Negative
0.05 mg/cm2
0.09
84 9235 Office
Rm. 05
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
85 9235 Office
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/cm2
0.02
86 926501
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
87 926501
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
SS 926501
Rm. 02
C
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
89 926501
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
90 926501
Rm. 02
A
Door
Casing
Wood
Stained
Intact
Negative
0.04 mg/cm2
0.06
91 926501
Rm. 02
A
Door
Wood
Stained
Intact
Negative
0.05 mg/cm2
0.14
92 926501
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
93 926501
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0.04 mg/cm2
0.64
94 926501
Rm. 03
D
Closet
Shelf
Wood
White
Intact
Negative
0 mg/cm2
0.02
95 926501
Rm. 04
B
Ceiling
Drywall
White
Intact
Negative
0 mg/cm2
0.02
96 926501
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0 mg/cm2
0.02
97 926501
Rm. 04
B
Wall
Radiator
Metal
White
Intact
Negative
0 mg/cm2
0.02
98 926501
Rm. 04
B
Door
Casing
Wood
White
Intact
Negative
0 mg/Cm2
0.02
99 926501
Rm. 04
B
Door
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
100 926504
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
101 926504
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
102 926504
Rm. 01
D
Wall
Baseboard
Wood
White
Intact
Negative
0.01 mg/Cm2
0.04
103 926504
Rm. 01
B
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
104 926504
Rm. 01
B
Cabinet
Frame
Wood
White
Intact
Negative
0.24 mg/Cm2
0.23
105 926504
Rm. 02
B
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
106 926504
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
107 926504
Rm. 02
D
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
108 926504
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
109 926504
Rm. 03
B
Door
Jamb
Wood
Stained
Intact
Negative
0.16 mg/Cm2
0.18
110 926504
Rm. 03
B
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
111 926504
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
112 926504
Rm. 04
A
Door
Casing
Wood
White
Intact
Negative
0 mg/Cm2
0.02
113 926504
Rm. 04
A
Door
Metal
White
Intact
Negative
0 mg/Cm2
0.02
114 926506
Rm. 01
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
115 926506
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
116 926506
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0.01 mg/Cm2
0.03
117 926506
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
118 926506
Rm. 02
D
Door
Jamb
Metal
White
Intact
Negative
0.05 mg/Cm2
0.08
119 926506
Rm. 02
D
Door
Metal
White
Intact
Negative
0 mg/Cm2
0.02
120 926506
Rm. 02
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
121 926506
Rm. 03
A
Door
Jamb
Wood
White
Intact
Negative
0.07 mg/Cm2
0.09
122 926506
Rm. 03
A
Door
Wood
White
Intact
Negative
0.05 mg/Cm2
0.07
123 926506
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
124 926506
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
125 926506
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
126 926506
Rm. 04
B
Door
Jamb
Wood
White
Intact
Negative
0.06 mg/Cm2
0.09
127 926506
Rm. 04
B
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
128 926506
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
129 926506
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
130 926506
Rm. 05
A
Door
Casing
Wood
White
Intact
Negative
0 mg/Cm2
0.02
131 926506
Rm. 05
A
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
132 926512
Rm. 01
D
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
133 926512
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
134 926512
Rm. 01
D
Wall
Shelf
Wood
White
Intact
Negative
0.02 mg/Cm2
0.07
135 926512
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
136 926512
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
137 926512
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
138 926512
Rm. 02
D
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
139 926512
Rm. 02
D
Door
Casing
Wood
Brown
Intact
Negative
0.28 mg/Cm2
0.22
140 926512
Rm. 02
D
Door
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
141 926512
Rm. 03
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
142 926512
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
143 926512
Rm. 03
B
Closet
Door
Wood
Brown
Intact
Negative
0.08 mg/Cm2
0.1
144 926512
Rm. 03
B
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
145 926512
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
146 926512
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
147 926512
Rm. 04
A
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
148 926512
Rm. 04
A
Door
Casing
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
149 926512
Rm. 04
A
Door
Wood
Brown
Intact
Negative
0.01 mg/Cm2
0.03
150 926513
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
151 926513
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
152 926513
Rm. 01
D
Cabinet
Door
Wood
White
Intact
Negative
0.01 mg/Cm2
0.03
153 926513
Rm. 01
D
Cabinet
Frame
Wood
White
Intact
Negative
0 mg/Cm2
0.02
154 926513
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
155 926513
Rm. 02
A
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
156 926513
Rm. 02
A
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
157 926513
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
158 926513
Rm. 03
B
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
159 926513
Rm. 04
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
160 926513
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
161 926513
Rm. 04
B
Wall
Radiator
Metal
White
Intact
Negative
0.01 mg/Cm2
0.05
162 926513
Rm. 04
D
Cabinet
Door
Wood
White
Intact
Negative
0.01 mg/Cm2
0.04
163 926513
Rm. 04
D
Cabinet
Frame
Wood
White
Intact
Negative
0.28 mg/Cm2
0.2
164 926518
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
165 926518
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
166 926518
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
167 926518
Rm. 01
B
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
168 926518
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
169 926518
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
170 926518
Rm. 02
A
Wall
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
171 926518
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
172 926518
Rm. 03
B
Cabinet
Door
Wood
White
Intact
Negative
0.01 mg/Cm2
0.03
173 926518
Rm. 03
B
Cabinet
Frame
Wood
White
Intact
Negative
0 mg/Cm2
0.02
174 926518
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
175 926518
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
176 926518
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
177 926518
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
178 926518
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
179 926518
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
180 926518
Rm. 05
A
Door
Casing
Wood
Stained
Intact
Negative
0.01 mg/Cm2
0.05
181 926518
Rm. 05
A
Door
Wood
Stained
Intact
Negative
0.02 mg/Cm2
0.07
182 9265 Laundry
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
183 9265 Laundry
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
184 9265 Laundry
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
185 9265 Laundry
Rm. 01
A
Door
Jamb
Wood
Brown
Intact
Negative
0.01 mg/Cm2
0.03
186 9265 Laundry
Rm. 01
A
Door
Wood
Brown
Intact
Negative
0.1 mg/Cm2
0.21
187 9265 Laundry
Rm. 01
B
Wall
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
188 9295101
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
189 9295101
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
190 9295101
Rm. 02
A
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
191 9295101
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
192 9295101
Rm. 02
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
193 9295101
Rm. 02
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
194 9295101
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
195 9295101
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
196 9295101
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
197 9295101
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
198 9295101
Rm. 03
B
Cabinet
Door
Wood
White
Intact
Negative
0.27 mg/Cm2
0.2
199 9295101
Rm. 05
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
200 9295101
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
201 9295101
Rm. 05
C
Door
Jamb
Wood
Brown
Intact
Negative
0.11 mg/Cm2
0.13
202 9295101
Rm. 05
B
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.03
203 9295102
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
204 9295102
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
205 9295102
Rm. 01
B
Cabinet
Door
Wood
White
Intact
Negative
0.3 mg/Cm2
0.25
206 9295102
Rm. 01
C
Wall
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
207 9295102
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
208 9295102
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
209 9295102
Rm. 03
A
Door
Jamb
Wood
Brown
Intact
Negative
0.11 mg/Cm2
0.14
210 9295102
Rm. 03
A
Door
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
211 9295102
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
212 9295102
Rm. 03
A
Closet
Door
Metal
White
Intact
Negative
0 mg/Cm2
0.02
213 9295102
Rm. 04
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
214 9295102
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
215 9295102
Rm. 04
B
Wall
Radiator
Metal
White
Intact
Negative
0.06 mg/Cm2
0.11
216 9295102
Rm. 04
B
Door
Casing
Wood
Brown
Intact
Negative
0.09 mg/Cm2
0.1
217 9295103
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
218 9295103
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
219 9295103
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
220 9295103
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0.02 mg/Cm2
0.12
221 9295103
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
222 9295103
Rm. 02
A
Closet
Door
Metal
White
Intact
Negative
0 mg/Cm2
0.02
223 9295103
Rm. 02
A
Closet
Shelf
Wood
White
Intact
Negative
0.01 mg/Cm2
0.04
224 9295103
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
225 9295103
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
226 9295103
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
227 9295103
Rm. 05
B
Cabinet
Door
Wood
Stained
Intact
Negative
0.4 mg/Cm2
0.3
228 9295103
Rm. 05
C
Door
Jamb
Wood
Brown
Intact
Negative
0.4 mg/Cm2
0.4
229 9295103
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
230 9295103
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
231 9295107
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
232 9295107
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
233 9295107
Rm. 01
A
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
234 9295107
Rm. 02
D
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
235 9295107
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
236 9295107
Rm. 02
D
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
237 9295107
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
238 9295107
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
239 9295107
Rm. 04
A
Door
Jamb
Wood
Brown
Intact
Negative
0.16 mg/Cm2
0.17
240 9295107
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
241 9295107
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
242 9295107
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
243 9295107
Rm. 05
A
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
244 9295107
Rm. 05
D
Cabinet
Frame
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
245 9295205
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
246 9295205
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
247 9295205
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
248 9295205
Rm. 01
A
Door
Jamb
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
249 9295205
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
250 9295205
Rm. 02
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
251 9295205
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
252 9295205
Rm. 03
D
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
253 9295205
Rm. 03
D
Wall
Drywall
White
Intact
Negative
0.01 mg/Cm2
0.02
2549295205
Rm. 03
D
Cabinet
Door
Wood
White
Intact
Negative
0.3 mg/Cm2
0.22
255 9295205
Rm. 04
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
256 9295205
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
257 9295205
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
-0.08 mg/Cm2
0.93
2589295205
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0.01 mg/Cm2
0.02
259 9295205
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
260 9295 Laundry
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
261 9295 Laundry
Rm. 01
C
Wall
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
262
Calibrate
Positive
1 mg/Cm2
0.1
263
Calibrate
Positive
1 mg/Cm2
0.1
264
Calibrate
Positive
1 mg/Cm2
0.1
265 932508
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
266 932508
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
267 932508
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0.4 mg/Cm2
0.4
268 932508
Rm. 02
B
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
269 932508
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
270932508
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0.01 mg/Cm2
0.06
271 932508
Rm. 02
A
Door
Wood
Brown
Intact
Negative
0.21 mg/Cm2
0.15
272 932508
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
273 932508
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
274 932508
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
275 932508
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
276 932508
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
277 932508
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
278932508
Rm. 04
A
Door
Jamb
Wood
White
Intact
Negative
0.19 mg/Cm2
0.19
279 932508
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
280 932508
Rm. 05
B
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
281 932508
Rm. 05
D
Closet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
282 932508
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
283 932508
Rm. 05
C
Door
Jamb
Wood
White
Intact
Negative
0 mg/Cm2
0.02
284 932517
Rm. 01
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
285 932517
Rm. 01
C
Cabinet
Door
Wood
White
Intact
Negative
0.07 mg/Cm2
0.18
286 932517
Rm. 02
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
287 932517
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
288 932517
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
289 932517
Rm. 02
A
Door
Casing
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
290 932517
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
291 932517
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
292 932517
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
293 932517
Rm. 03
A
Door
Jamb
Wood
Stained
Intact
Negative
0.27 mg/Cm2
0.21
294 932517
Rm. 03
A
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
295 932517
Rm. 05
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
296 932517
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
297 932517
Rm. 05
B
Cabinet
Frame
Wood
White
Intact
Negative
0.26 mg/Cm2
0.21
298 932515
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0.02 mg/Cm2
0.09
299 932518
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
300 932518
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0.18 mg/Cm2
0.23
301 932518
Rm. 01
A
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.03
302 932518
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
303 932518
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0.03 mg/Cm2
0.11
304 932518
Rm. 02
A
Door
Casing
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
305 932518
Rm. 02
A
Door
Wood
Stained
Intact
Negative
0.17 mg/Cm2
0.17
306 932518
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
307 932518
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
308 932518
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
309 932518
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
310 932518
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
311 932518
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
312 932518
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
313 932518
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
314 932520
Rm. 01
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
315 932520
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
316 932520
Rm. 01
A
Door
Jamb
Wood
Brown
Intact
Negative
0.01 mg/Cm2
0.05
317 932520
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
318 932520
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0 mg/Cm2
0.02
319 932520
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
320 932520
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
321 932520
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
322 932520
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
323 932520
Rm. 04
A
Door
Jamb
Wood
Stained
Intact
Negative
0.28 mg/Cm2
0.22
324 932520
Rm. 04
A
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
325 932520
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
326 932520
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
327 932520
Rm. 05
B
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
328 932520
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
329 932520
Rm. 12
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
330 932520
Rm. 12
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
331 932520
Rm. 12
A
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
332 932520
Rm. 02
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
333 932520
Rm. 02
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
334 932520
Rm. 02
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
335 932520
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
336 932520
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
337 932520
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
338932520
Rm. 03
A
Door
Jamb
Wood
Stained
Intact
Negative
0.21 mg/Cm2
0.17
339 932520
Rm. 03
A
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
340 932520
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
341 932520
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
342 932520
Rm. 03
B
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
343 932520
Rm. 04
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
344 932520
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
345 932520
Rm. 04
C
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
346 932520
Rm. 04
D
Door
Casing
Wood
Stained
Intact
Negative
0.4 mg/Cm2
0.3
347 932520
Rm. 04
D
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
348 935503
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
349 935503
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
350 935503
Rm. 01
A
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
351 935503
Rm. 02
A
Door
Casing
Wood
Brown
Intact
Negative
0 mg/Cm2
0.02
352 935503
Rm. 02
A
Door
Wood
Brown
Intact
Negative
0.03 mg/Cm2
0.07
353 935503
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
354 935503
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
355 935503
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
356 935503
Rm. 03
A
Wall
Drywall
White
Intact
Negative
-0.13 mg/Cm2
0.81
357 935503
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
358 935503
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
359 935503
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
360 935503
Rm. 03
A
Closet
Jamb
Wood
White
Intact
Negative
0 mg/Cm2
0.02
361 935503
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
362 935503
Rm. 03
A
Door
Jamb
Wood
White
Intact
Negative
0.4 mg/Cm2
0.5
363 935503
Rm. 04
A
Door
Casing
Wood
White
Intact
Negative
0.28 mg/Cm2
0.43
364 935503
Rm. 04
A
Closet
Jamb
Wood
White
Intact
Negative
0 mg/Cm2
0.02
365 935503
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
366 935503
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
367 935503
Rm. 05
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
368 935503
Rm. 05
D
Closet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
369 935503
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
370 935503
Rm. 05
B
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
371 935503
Rm. 05
C
Door
Jamb
Wood
White
Intact
Negative
0.17 mg/Cm2
0.2
372 935503
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
373 935506
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
374 935506
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
375 935506
Rm. 01
A
Door
Casing
Wood
Stained
Intact
Negative
0.4 mg/Cm2
0.3
376 935506
Rm. 01
A
Door
Wood
Stained
Intact
Negative
0.08 mg/Cm2
0.1
377 935506
Rm. 02
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
378 935506
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
379 935506
Rm. 03
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
380 935506
Rm. 03
D
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
381 935506
Rm. 03
D
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
382 935506
Rm. 03
B
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
383 935506
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
384 935506
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
385 935506
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
386 935506
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0.02 mg/Cm2
0.09
387 935506
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
388 935506
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
389 935506
Rm. 05
B
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
390 935510
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
391 935510
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
392 935510
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
393 935510
Rm. 01
B
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
394 935510
Rm. 01
B
Cabinet
Frame
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
395 935510
Rm. 02
C
Ceiling
Drywall
Stained
Intact
Negative
0 mg/Cm2
0.02
396 935510
Rm. 02
C
Wall
Drywall
Stained
Intact
Negative
0 mg/Cm2
0.02
397 935510
Rm. 02
C
Door
Casing
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
398 935510
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
399 935510
Rm. 03
B
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
400 935510
Rm. 03
B
Door
Wood
Stained
Intact
Negative
0.26 mg/Cm2
0.2
401 935510
Rm. 03
B
Door
Wood
Stained
Intact
Negative
0.11 mg/Cm2
0.12
402 935510
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
403 935510
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
404 935510
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
405 935510
Rm. 05
D
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
406 935510
Rm. 05
D
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
407 935510
Rm. 05
D
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
408 935513
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
409 935513
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
410 935513
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0.4 mg/Cm2
0.3
411 935513
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
412 935513
Rm. 02
C
Door
Casing
Wood
White
Intact
Negative
0 mg/Cm2
0.02
413 935513
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
414 935513
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
415 935513
Rm. 04
A
Door
Jamb
Wood
Stained
Intact
Negative
0.23 mg/Cm2
0.18
416 935513
Rm. 04
A
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
417 935513
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0 mg/Cm2
0.02
418 935513
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
419 935513
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
420 935513
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
421 935513
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
422 935513
Rm. 05
B
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
423 935513
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
424 935521
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
425 935521
Rm. 04
C
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
426 935521
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
427 935521
Rm. 04
C
Wall
Baseboard
Wood
White
Intact
Negative
0 mg/Cm2
0.02
428 935521
Rm. 04
C
Door
Jamb
Wood
White
Intact
Negative
0 mg/Cm2
0.02
429 935521
Rm. 04
C
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
430 935521
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
431 935521
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
432 935521
Rm. 05
B
Cabinet
Frame
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
433 935521
Rm. 05
B
Cabinet
Door
Wood
Stained
Intact
Negative
0 mg/Cm2
0.02
434 935521
Rm. 07
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
435 935521
Rm. 07
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
436 935521
Rm. 07
A
Cabinet
Door
Wood
White
Intact
Negative
0 mg/Cm2
0.02
437 935521
Rm. 07
B
Door
Jamb
Wood
Brown
Intact
Negative
0.4 mg/Cm2
0.2
438935521
Rm. 07
B
Door
Wood
Stained
Intact
Negative
0.26 mg/Cm2
0.25
439 935521
Rm. 09
A
Ceiling
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
440 935521
Rm. 09
A
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
441 935521
Rm. 09
B
Wall
Drywall
White
Intact
Negative
0 mg/Cm2
0.02
442 935521
Rm. 09
B
Closet
Shelf
Wood
White
Intact
Negative
0 mg/Cm2
0.02
443 935521
Rm. 09
C
Window
Sill
Wood
White
Intact
Negative
0 mg/Cm2
0.02
444 935521
Rm. 09
C
Window
Casing
Wood
White
Intact
Negative
0 mg/Cm2
0.02
445 935521
Rm. 09
D
Door
Jamb
Wood
White
Intact
Negative
0 mg/Cm2
0.02
446
Calibrate
Positive
1 mg/Cm2
0.1
447
Calibrate
Positive
1 mg/Cm2
0.1
448
Calibrate
Positive
1.1 mg/Cm2
0.1
APPENDIX B: SAMPLE LOCATIONS
PARTNER
Side C
Rm 4
Bath
RM 5
Rut 3
Bedroom
Bedroom
1VBA02
SideSide
�j
-B
1W03 1CO3
"
Rm 2
Living
Rut 1
Kitchen
1 F02
Unit 9235-06
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 4
Bath
RM 5
Rut 3
Bedroom
Bedroom
Side
1W07 Side
B
Rm 2 1C07
Living
Rut 1
Kitchen
Unit 9235-11
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 2 1co5
Bath Rm 3
Bedroom
Side
Side 1W05 D
1F04
Rm 1
Kitchen R1114
1C04 Living
Unit 9235=19
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 3
2 Bath Rm 4
Bedroom Bedroom
Side 1W06 Side
1 C0
Rm 1 Rm 5
Kitchen Living
Unit 9235-20
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 4
Bath Rm 5
Rm 3
Bedroom Bedroom
1CO2
Side 1102 Spe
1 W01
Rm 2 1
LiOg Rm
1VBA01 Kitchen
1C01 1F01
Unit 9235=Office
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 3 Rm 4
Bath
Bedroom
2W0
Side
Side D
B 1F02
Rm 1
Rm 2 2CO3 Kitchen
Living
Unit 9265-01
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rs h Rm 3
2WO4 Bedroom
2VBA02
Side
Side 2F03 D
Rm 1
Kitchen RM 4
2CO4 Living
Unit 9265-04
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rill 3
Bath RM 4
RM 2
Bedroom Bedroom
Side 2WO5 Side
2CO5
RM 1 RM 5
Kltcher Living
Unit 9265-06
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Ba2
Bath 1W02 Rm 3
Bedroom
1CO2
1F01 Me
Side 1W01 D
B 1VBA01
Rm 1 1C01
Kitchen RM 4
Living
Unit 9265=12
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 4
Rm 3 Bath
Kitchen
Living
Bedroom
2C07
Side
BF
Side
D
Rm 1
RM
Unit 9265-13
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM
19-258685 2
Project No. PARTNER
2
Kitchen
Living
2C07
2W07
Side C
Rm 3
Bath RITZ 4
RM 2
Bedroom Bedroom
Se Side
2CO6
Rm 1 Rm 5
Kitchen Living
Unit 9265=18
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX H: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Re C
RM 3
Bath
Rm 4
Rm 2 4VBA0
Bedroom
4FO2
Living
SB e
Side
RM 5
4003
1
Bedroom
Kitchen
4WO3
Unit 9295-101
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm2 Rm3
Living
Bedroom
3C05 Side
Side
B
Rm 1
Kitchen
Rm 4
3W06 Bath
Unit 9295-102
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 2 RM 3 RM 4
Living
Bedroom Bedroom
&de 3W01 Side
B
RM 1 3F01 3VBAO1
RM 5
Kltcher Bath
3C01
Unit 9295-103
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 4 Rm 3
Bedroom Bedroom
Side 3W02B Rm2 Snide
3CO2 Living
Rm 5 Rm 1
Bath Kitchen
Unit 9295-107
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
3C06
Rm 4 Rm 3 Rm 2
Bedroom Bath
Lyng
3C07
Side
Side D
B
Rm 5 Rm 1
Bedroom Kitchen
3W07
Unit 9295=205
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 2 Rm 3 Rm 4
Bedroom Bedroom
Living
Side
4WO2
Side
4FO1
Rm 1 Rm 5
Kitchen Bath
4WO1 4VBAO
Unit 9325=08
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 3 Rm 2
Bedroom Living
Side
B Side
D
Rm 4 Rm 1
Unit 9325-12
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM
No. 19-258685 2
Project PARTNER
Bath
4W07
Kitchen
a
Side C
Unit 9325-17
Side A
Caesar's Square Apartments
Not To Scale
Side
D
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Rm 2 Rm 3
Bedroom
Living
Rm 4
Bedroom
4W04
Rll1 1 4F02
RM 5
Kitchen
Bath
4W03
Unit 9325-17
Side A
Caesar's Square Apartments
Not To Scale
Side
D
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Living
Bedroom
Rm 2 Rm 3 Rm 4
4W05
Side
Rm 5
Side
B
Bath
4F03
Unit 9325=18
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM
2
Project No. 19-258685 PARTNER
Living
Bedroom
Bedroom
4W05
Rm 1
Rm 5
Kitchen
Bath
4F03
5ide
Rm4 Bm3 Rm2
Bedroom
Living
Side Side
4W06
Rm 5 Rm 1
Bedroom Kitchen
Unit 9325=20
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX H: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 2 Rm 3 Rm 4
Living
Bedroom Bedroom
Side Side
B
5VBA02 5W03
Rm 1 5F02 Rm 5
Kitchen Bath
Unit 9355-03
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 4 Rm 3
Bedroom Bath Rm 2
Living
Side Side
B D
Rm 5 Rm 1
Bedroom Kitchen
5WO4
Unit 9355-06
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
&de C
Rm 3
Bath Rm 4
Rm 2 5W02 Bedroom
Living Side
SB e p
5WO1
5VBAO1 Rm 5
Rin 1 Bedroom
Kitchen
5FO1
Unit 9355-10
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm 2 Rm 3 Rm 4
Bedroom Bedroom
Living
Side
Side
5W07
Rm 1 Rm 5
Kitchen Bath
Unit 9355-13
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
Side C
Rm8
Bedroom
Rm 10
Rm 9
Bedroom
Bedroom
Rm 7
Side
Bath
B
Rm 3
Hall 5W06
Side
D
5W05
Rm 2 trM I
Entry
Rm 4 Rm 5
Rm 6
Utility
Den Kitchen
Living
Unit 9355-21
Side A
Caesar's Square Apartments
Not To Scale
APPENDIX B: SAMPLE LOCATION DIAGRAM PARTNER
Project No. 19-258685 2
APPENDIX C: CERTIFICATIONS
PARTNER
Colorado Department
of Public Health
and Environment
LEAD-BASED PAINT
CERTIFICATION*
This certifies that
John Burnside
Certification No.: 11876
has met the requirements of 25-7-1104, C.R.S. and Air Quality Control
Commission Regulation No. 19, and is hereby certified by the state of
Colorado in the following discipline:
Risk Assessor*
Issued: November 06, 2018
Expires: December 09, 2019
`This certificate is valid only with the possession of a valid
lead-based paint training certificate in the discipline specified
above, issued by either a Colorado approved training provider,
an EPA approved training provider, or a training provider
approved by another EPA authorized program.
APM Representative
SEAL
APPENDIX D: PHOTOGRAPHIC DOCUMENTATION
PARTNER
AmaD°STTEP"oToG�s PARTNER
Project No. 19-258685 2
AmaD°STTEP"oToG�s PARTNER
Project No. 19-258685 2
AmaD°STTEP"oToG�s PARTNER
Project No. 19-258685 2
AmaD°STTEP"oToG�s PARTNER
Project No. 19-258685 2
APPENDIX E: XRF SAMPLING RESULTS
PARTNER
I
Calibrate
Positive
1
mg/cm2
0.1
2
Calibrate
Positive
1
mg/cm2
0.1
3
Calibrate
Positive
1
mg/cm2
0.1
4
923506
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
5
923506
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
6
923506
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
7
923506
Rm. 01
C
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
S
923506
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
9
923506
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
10
923506
Rm. 02
A
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
11
923506
Rm. 02
A
Door
Casing
Wood
Black
Intact
Negative
0.02
mg/cm2
0.04
12
923506
Rm. 02
A
Door
Wood
Stained
Intact
Negative
0.03
mg/cm2
0.05
13
923506
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
14
923506
Rm. 03
A
Closet
Door
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
15
923506
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
16
923506
Rm. 04
D
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
17
923506
Rm. 04
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
16
923506
Rm. 04
D
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
19
923506
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
20
923506
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
21
923506
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
22
923506
Rm. 05
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
23
923511
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
24
923511
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
25
923511
Rm. 01
D
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
26
923511
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cmc
0.02
27
923511
Rm. 02
A
Door
Casing
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
26
923511
Rm. 02
A
Door
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
29
923511
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
30
923511
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
31
923511
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
32
923511
Rm. 04
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
33
923511
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
34
923511
Rm. 05
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
35
923511
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
36
923519
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
37
923519
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
36
923519
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
39
923519
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
40
923519
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
41
923519
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
42
923519
Rm. 03
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
43
923519
Rm. 03
D
Wall
Radiator
Metal
White
Intact
Negative
0.02
mg/cm2
0.1
44
923519
Rm. 03
D
Door
Jamb
Wood
Brown
Intact
Negative
0.2
mg/cm2
0.22
45
923519
Rm. 03
D
Door
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
46
923519
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
47
923519
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0.05
mg/cm2
0.9
46
923519
Rm. 04
B
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
49
923520
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
50
923520
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
51
923520
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
52
923520
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
53
923520
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cmc
0.02
54
923520
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
55
923520
Rm. 02
D
Door
Jamb
Wood
White
Intact
Negative
0.03
mg/cm2
0.05
56
923520
Rm. 02
D
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
57
923520
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
56
923520
Rm. 03
A
Door
Jamb
Wood
White
Intact
Negative
0.12
mg/cm2
0.22
59
923520
Rm. 03
A
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
60
923520
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
61
923520
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0.01
mg/cm2
0.06
62
923520
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
63
923520
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
64
9235
Laundry
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
65
9235
Laundry
Rm. 01
A
Wall
Drywall
Green
Intact
Negative
0
mg/cm2
0.02
66
9235
Laundry
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
67
9235
Laundry
Rm. 01
A
Door
Casing
Wood
Brown
Intact
Negative
0.01
mg/cm2
0.03
66
9235
Laundry
Rm. 01
A
Door
Wood
Brown
Intact
Negative
0.02
mg/cm2
0.06
69
9235
Office
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
70
9235
Office
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
71
9235
Office
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
72
9235
Office
Rm. 01
C
Cabinet
Door
Wood
Stained
Intact
Negative
0.03
mg/cm2
0.06
73
9235
Office
Rm. 01
A
Wall
Drywall
Tan
Intact
Negative
0
mg/cm2
0.02
74
9235
Office
Rm. 01
B
Wall
Drywall
Tan
Intact
Negative
0
mg/cm2
0.02
75
9235
Office
Rm. 01
B
Wall
Chair Rail
Wood
White
Intact
Negative
0
1 mg/cm2
0.02
76
9235
Office
Rm. 03
A
Wall
Drywall
Tan
Intact
Negative
0
mg/cm2
0.02
77
9235
Office
Rm. 03
D
Door
Jamb
Wood
Stained
Intact
Negative
0.13
mg/cm2
0.14
76
9235
Office
Rm. 03
D
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
79
9235
Office
Rm. 03
D
Closet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
SO
9235
Office
Rm. 03
D
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
81
9235
Office
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
82
9235
Office
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
83
9235
Office
Rm. 04
D
Cabinet
Frame
Wood
Stained
Intact
Negative
0.05
mg/cm2
0.09
84
9235
Office
Rm. 05
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
85
9235
Office
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
86
926501
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
87
926501
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
SS
926501
Rm. 02
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
89
926501
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
90
926501
Rm. 02
A
Door
Casing
Wood
Stained
Intact
Negative
0.04
mg/cm2
0.06
91
926501
Rm. 02
A
Door
Wood
Stained
Intact
Negative
0.05
mg/cm2
0.14
92
926501
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
93
926501
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0.04
mg/cm2
0.64
94
926501
Rm. 03
D
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
95
926501
Rm. 04
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
96
926501
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
97
926501
Rm. 04
B
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
98
926501
Rm. 04
B
Door
Casing
Wood
White
Intact
Negative
0
mg/cm2
0.02
99
926501
Rm. 04
B
Door
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
100
926504
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
101
926504
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
102
926504
Rm. 01
D
Wall
Baseboard
Wood
White
Intact
Negative
0.01
mg/cm2
0.04
103
926504
Rm. 01
B
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
104
926504
Rm. 01
B
Cabinet
Frame
Wood
White
Intact
Negative
0.24
mg/cm2
0.23
105
926504
Rm. 02
B
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
106
926504
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
107
926504
Rm. 02
D
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
108
926504
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
109
926504
Rm. 03
B
Door
Jamb
Wood
Stained
Intact
Negative
0.16
mg/cm2
0.18
110
926504
Rm. 03
B
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
111
926504
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
112
926504
Rm. 04
A
Door
Casing
Wood
White
Intact
Negative
0
mg/cm2
0.02
113
926504
Rm. 04
A
Door
Metal
White
Intact
Negative
0
mg/cm2
0.02
114
926506
Rm. 01
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
115
926506
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
116
926506
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0.01
mg/cm2
0.03
117
926506
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
118
926506
Rm. 02
D
Door
Jamb
Metal
White
Intact
Negative
0.05
mg/cm2
0.08
119
926506
Rm. 02
D
Door
Metal
White
Intact
Negative
0
mg/cm2
0.02
120
926506
Rm. 02
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
121
926506
Rm. 03
A
Door
Jamb
Wood
White
Intact
Negative
0.07
mg/cm2
0.09
122
926506
Rm. 03
A
Door
Wood
White
Intact
Negative
0.05
mg/cm2
0.07
123
926506
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0
mg/cmc
0.02
124
926506
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
125
926506
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
126
926506
Rm. 04
B
Door
Jamb
Wood
White
Intact
Negative
0.06
mg/cm2
0.09
127
926506
Rm. 04
B
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
128
926506
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
129
926506
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
130
926506
Rm. 05
A
Door
Casing
Wood
White
Intact
Negative
0
mg/cm2
0.02
131
926506
Rm. 05
A
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
132
926512
Rm. 01
D
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
133
926512
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
134
926512
Rm. 01
D
Wall
Shelf
Wood
White
Intact
Negative
0.02
mg/cm2
0.07
135
926512
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
136
926512
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
137
926512
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
138
926512
Rm. 02
D
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
139
926512
Rm. 02
D
Door
Casing
Wood
Brown
Intact
Negative
0.28
mg/cm2
0.22
140
926512
Rm. 02
D
Door
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
141
926512
Rm. 03
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
142
926512
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
143
926512
Rm. 03
B
Closet
Door
Wood
Brown
Intact
Negative
0.08
mg/cm2
0.1
144
926512
Rm. 03
B
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
145
926512
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
146
926512
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
147
926512
Rm. 04
A
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
148
926512
Rm. 04
A
Door
Casing
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
149
926512
Rm. 04
A
Door
Wood
Brown
Intact
Negative
0.01
mg/cm2
0.03
150
926513
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cmc
0.02
151
926513
Rm. 01
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
152
926513
Rm. 01
D
Cabinet
Door
Wood
White
Intact
Negative
0.01
mg/cm2
0.03
153
926513
Rm. 01
D
Cabinet
Frame
Wood
White
Intact
Negative
0
mg/cm2
0.02
154
926513
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
155
926513
Rm. 02
A
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
156
926513
Rm. 02
A
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
157
926513
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
158
926513
Rm. 03
B
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
159
926513
Rm. 04
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
160
926513
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
161
926513
Rm. 04
B
Wall
Radiator
Metal
White
Intact
Negative
0.01
mg/cm2
0.05
162
926513
Rm. 04
D
Cabinet
Door
Wood
White
Intact
Negative
0.01
mg/cm2
0.04
163
926513
Rm. 04
D
Cabinet
Frame
Wood
White
Intact
Negative
0.28
mg/cm2
0.2
164
926518
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
165
926518
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
166
926518
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
167
926518
Rm. 01
B
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
168
926518
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
169
926518
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
170
926518
Rm. 02
A
Wall
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
171
926518
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
172
926518
Rm. 03
B
Cabinet
Door
Wood
White
Intact
Negative
0.01
mg/cm2
0.03
173
926518
Rm. 03
B
Cabinet
Frame
Wood
White
Intact
Negative
0
mg/cm2
0.02
174
926518
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
175
926518
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
176
926518
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
177
926518
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cmc
0.02
178
926518
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
179
926515
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
180
926515
Rm. 05
A
Door
Casing
Wood
Stained
Intact
Negative
0.01
mg/cm2
0.05
181
926518
Rm. 05
A
Door
Wood
Stained
Intact
Negative
0.02
mg/cm2
0.07
182
9265
Laundry
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
183
9265
Laundry
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
184
9265
Laundry
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
185
9265
Laundry
Rm. 01
A
Door
Jamb
Wood
Brown
Intact
Negative
0.01
mg/cm2
0.03
186
9265
Laundry
Rm. 01
A
Door
Wood
Brown
Intact
Negative
0.1
mg/cm2
0.21
187
9265
Laundry
Rm. 01
B
Wall
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
188
9295101
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
189
9295101
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
190
9295101
Rm. 02
A
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
191
9295101
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
192
9295101
Rm. 02
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
193
9295101
Rm. 02
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
194
9295101
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
195
9295101
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
196
9295101
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
197
9295101
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
198
9295101
Rm. 03
B
Cabinet
Door
Wood
White
Intact
Negative
0.27
mg/cm2
0.2
199
9295101
Rm. 05
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
200
9295101
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
201
9295101
Rm. 05
C
Door
Jamb
Wood
Brown
Intact
Negative
0.11
mg/cm2
0.13
202
9295101
Rm.05
B
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.03
203
9295102
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
204
9295102
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
205
9295102
Rm. 01
B
Cabinet
Door
Wood
White
Intact
Negative
0.3
mg/cm2
0.25
206
9295102
Rm. 01
C
Wall
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
207
9295102
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
208
9295102
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
209
9295102
Rm. 03
A
Door
Jamb
Wood
Brown
Intact
Negative
0.11
mg/cm2
0.14
210
9295102
Rm. 03
A
Door
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
211
9295102
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
212
9295102
Rm. 03
A
Closet
Door
Metal
White
Intact
Negative
0
mg/cm2
0.02
213
9295102
Rm. 04
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
214
9295102
Rm. 04
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
215
9295102
Rm. 04
B
Wall
Radiator
Metal
White
Intact
Negative
0.06
mg/cm2
0.11
216
9295102
Rm. 04
B
Door
Casing
Wood
Brown
Intact
Negative
0.09
mg/cm2
0.1
217
9295103
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
218
9295103
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
219
9295103
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
220
9295103
Rm. 01
B
Wall
Radiator
Metal
White
Intact
Negative
0.02
mg/cm2
0.12
221
9295103
Rm. 02
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
222
9295103
Rm. 02
A
Closet
Door
Metal
White
Intact
Negative
0
mg/cm2
0.02
223
9295103
Rm. 02
A
Closet
Shelf
Wood
White
Intact
Negative
0.01
mg/cm2
0.04
224
9295103
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
225
9295103
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
226
9295103
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
227
9295103
Rm. 05
B
Cabinet
Door
Wood
Stained
Intact
Negative
0.4
mg/cm2
0.3
228
9295103
Rm.05
C
Door
Jamb
Wood
Brown
Intact
Negative
0.4
mg/cmc
0.4
229
9295103
Rm.04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
230
9295103
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
231
9295107
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
232
9295107
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
233
9295107
Rm. 01
A
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
234
9295107
Rm. 02
D
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
235
9295107
Rm. 02
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
236
9295107
Rm. 02
D
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
237
9295107
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
238
9295107
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
239
9295107
Rm. 04
A
Door
Jamb
Wood
Brown
Intact
Negative
0.16
mg/cm2
0.17
240
9295107
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
241
9295107
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
242
9295107
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
243
9295107
Rm. 05
A
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
244
9295107
Rm. 05
D
Cabinet
Frame
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
245
9295205
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
246
9295205
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
247
9295205
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
248
9295205
Rm. 01
A
Door
Jamb
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
249
9295205
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
250
9295205
Rm. 02
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
251
9295205
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
252
9295205
Rm. 03
D
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
253
9295205
Rm. 03
D
Wall
Drywall
White
Intact
Negative
0.01
mg/cm2
0.02
254
9295205
Rm. 03
D
Cabinet
Door
Wood
White
Intact
Negative
0.3
mg/cm2
0.22
255
9295205
Rm.04
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cmc
0.02
256
9295205
Rm.04
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
257
9295205
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
-0.1
mg/cm2
0.93
258
9295205
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0.01
mg/cm2
0.02
259
9295205
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
260
9295
Laundry
Rm. 01
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
261
9295
Laundry
Rm. 01
C
Wall
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
262
Calibrate
Positive
1
mg/cm2
0.1
263
Calibrate
Positive
1
mg/cm2
0.1
264
Calibrate
Positive
1
mg/cm2
0.1
265
932508
Rm. 01 A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
266
932508
Rm. 01 A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
267
932508
Rm. 01 A
Cabinet
Frame
Wood
White
Intact
Negative
0.4
mg/cm2
0.4
268
932508
Rm. 02 B
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
269
932508
Rm. 02 B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
270
932508
Rm. 02 B
Wall
Radiator
Metal
White
Intact
Negative
0.01
mg/cm2
0.06
271
932508
Rm. 02 A
Door
Wood
Brown
Intact
Negative
0.21
mg/cm2
0.15
272
932508
Rm. 03 A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
273
932508
Rm. 03 A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
274
932508
Rm. 03 C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
275
932508
Rm. 03 C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
276
932508
Rm. 03 C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
277
932508
Rm. 04 A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
278
932508
Rm. 04 A
Door
Jamb
Wood
White
Intact
Negative
0.19
mg/cm2
0.19
279
932508
Rm. 05 B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
280
932508
Rm. 05 B
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
281
932508
Rm. 05 D
Closet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
282
932508
Rm. 05 D
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
283
932505
Rm. 05
C
Door
Jamb
Wood
White
Intact
Negative
0
mg/cm2
0.02
284
932517
Rm. 01
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
285
932517
Rm. 01
C
Cabinet
Door
Wood
White
Intact
Negative
0.07
mg/cm2
0.18
286
932517
Rm. 02
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
287
932517
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
288
932517
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
289
932517
Rm. 02
A
Door
Casing
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
290
932517
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
291
932517
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
292
932517
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
293
932517
Rm. 03
A
Door
Jamb
Wood
Stained
Intact
Negative
0.27
mg/cm2
0.21
294
932517
Rm. 03
A
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
295
932517
Rm. 05
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
296
932517
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
297
932517
Rm. 05
B
Cabinet
Frame
Wood
White
Intact
Negative
0.26
mg/cm2
0.21
298
932518
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0.02
mg/cm2
0.09
299
932518
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
300
932518
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0.18
mg/cm2
0.23
301
932518
Rm. 01
A
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.03
302
932518
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
303
932518
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0.03
mg/cm2
0.11
304
932518
Rm. 02
A
Door
Casing
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
305
932518
Rm. 02
A
Door
Wood
Stained
Intact
Negative
0.17
mg/cm2
0.17
306
932518
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
307
932518
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
308
932518
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cmc
0.02
309
932518
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
310
932515
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
311
932515
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
312
932515
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
313
932515
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
314
932520
Rm. 01
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
315
932520
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
316
932520
Rm. 01
A
Door
Jamb
Wood
Brown
Intact
Negative
0.01
mg/cm2
0.05
317
932520
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
318
932520
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0
mg/cm2
0.02
319
932520
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
320
932520
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
321
932520
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
322
932520
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
323
932520
Rm. 04
A
Door
Jamb
Wood
Stained
Intact
Negative
0.28
mg/cm2
0.22
324
932520
Rm. 04
A
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
325
932520
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
326
932520
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
327
932520
Rm. 05
B
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
328
932520
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
329
932520
Rm. 12
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
330
932520
Rm. 12
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
331
932520
Rm. 12
A
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
332
932520
Rm. 02
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
333
932520
Rm. 02
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
334
932520
Rm. 02
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
335
932520
Rm. 02
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cmc
0.02
336
932520
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
337
932520
Rm. 03
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
338
932520
Rm. 03
A
Door
Jamb
Wood
Stained
Intact
Negative
0.21
mg/cm2
0.17
339
932520
Rm. 03
A
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
340
932520
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
341
932520
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
342
932520
Rm. 03
B
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
343
932520
Rm. 04
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
344
932520
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
345
932520
Rm. 04
C
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
346
932520
Rm. 04
D
Door
Casing
Wood
Stained
Intact
Negative
0.4
mg/cm2
0.3
347
932520
Rm. 04
D
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
348
935503
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
349
935503
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
350
935503
Rm. 01
A
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
351
935503
Rm. 02
A
Door
Casing
Wood
Brown
Intact
Negative
0
mg/cm2
0.02
352
935503
Rm. 02
A
Door
Wood
Brown
Intact
Negative
0.03
mg/cm2
0.07
353
935503
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
354
935503
Rm. 02
B
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
355
935503
Rm. 03
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
356
935503
Rm. 03
A
Wall
Drywall
White
Intact
Negative
-0.1
mg/cm2
0.81
357
935503
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
358
935503
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
359
935503
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
360
935503
Rm. 03
A
Closet
Jamb
Wood
White
Intact
Negative
0
mg/cm2
0.02
361
935503
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
362
935503
Rm. 03
A
Door
Jamb
Wood
White
Intact
Negative
0.4
mg/cmc
0.5
363
935503
Rm. 04
A
Door
Casing
Wood
White
Intact
Negative
0.28
mg/cm2
0.43
364
935503
Rm. 04
A
Closet
Jamb
Wood
White
Intact
Negative
0
mg/cm2
0.02
365
935503
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
366
935503
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
367
935503
Rm. 05
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
368
935503
Rm. 05
D
Closet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
369
935503
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
370
935503
Rm. 05
B
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
371
935503
Rm. 05
C
Door
Jamb
Wood
White
Intact
Negative
0.17
mg/cm2
0.2
372
935503
Rm. 05
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
373
935506
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
374
935506
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
375
935506
Rm. 01
A
Door
Casing
Wood
Stained
Intact
Negative
0.4
mg/cm2
0.3
376
935506
Rm. 01
A
Door
Wood
Stained
Intact
Negative
0.08
mg/cm2
0.1
377
935506
Rm. 02
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
378
935506
Rm. 02
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
379
935506
Rm. 03
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
380
935506
Rm. 03
D
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
381
935506
Rm. 03
D
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
382
935506
Rm. 03
B
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
383
935506
Rm. 03
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
384
935506
Rm. 03
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
385
935506
Rm. 03
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
386
935506
Rm. 03
A
Closet
Shelf
Wood
White
Intact
Negative
0.02
mg/cm2
0.09
387
935506
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
388
935506
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
389
935506
Rm. 05
B
Window
Sill
Wood
White
Intact
Negative
0
mg/cmc
0.02
390
935510
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
391
935510
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
392
935510
Rm. 01
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
393
935510
Rm. 01
B
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
394
935510
Rm. 01
B
Cabinet
Frame
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
395
935510
Rm. 02
C
Ceiling
Drywall
Stained
Intact
Negative
0
mg/cm2
0.02
396
935510
Rm. 02
C
Wall
Drywall
Stained
Intact
Negative
0
mg/cm2
0.02
397
935510
Rm. 02
C
Door
Casing
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
398
935510
Rm. 03
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
399
935510
Rm. 03
B
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
400
935510
Rm. 03
B
Door
Wood
Stained
Intact
Negative
0.26
mg/cm2
0.2
401
935510
Rm. 03
B
Door
Wood
Stained
Intact
Negative
0.11
mg/cm2
0.12
402
935510
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
403
935510
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
404
935510
Rm. 04
A
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
405
935510
Rm. 05
D
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
406
935510
Rm. 05
D
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
407
935510
Rm. 05
D
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
408
935513
Rm. 01
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
409
935513
Rm. 01
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
410
935513
Rm. 01
A
Cabinet
Frame
Wood
White
Intact
Negative
0.4
mg/cm2
0.3
411
935513
Rm. 01
A
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
412
935513
Rm. 02
C
Door
Casing
Wood
White
Intact
Negative
0
mg/cm2
0.02
413
935513
Rm. 04
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
414
935513
Rm. 04
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
415
935513
Rm. 04
A
Door
Jamb
Wood
Stained
Intact
Negative
0.23
mg/cm2
0.18
416
935513
Rm. 04
A
Door
Wood
Stained
Intact
Negative
0
mg/cmc
0.02
417
935513
Rm. 04
C
Wall
Radiator
Metal
White
Intact
Negative
0
mg/cm2
0.02
418
935513
Rm. 04
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cm2
0.02
419
935513
Rm. 05
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
420
935513
Rm. 05
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
421
935513
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
422
935513
Rm. 05
B
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
423
935513
Rm. 05
D
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
424
935521
Rm. 02
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
425
935521
Rm. 04
C
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
426
935521
Rm. 04
C
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
427
935521
Rm. 04
C
Wall
Baseboard
Wood
White
Intact
Negative
0
mg/cm2
0.02
428
935521
Rm. 04
C
Door
Jamb
Wood
White
Intact
Negative
0
mg/cm2
0.02
429
935521
Rm. 04
C
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
430
935521
Rm. 05
B
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
431
935521
Rm. 05
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
432
935521
Rm. 05
B
Cabinet
Frame
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
433
935521
Rm. 05
B
Cabinet
Door
Wood
Stained
Intact
Negative
0
mg/cm2
0.02
434
935521
Rm. 07
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
435
935521
Rm. 07
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
436
935521
Rm. 07
A
Cabinet
Door
Wood
White
Intact
Negative
0
mg/cm2
0.02
437
935521
Rm. 07
B
Door
Jamb
Wood
Brown
Intact
Negative
0.4
mg/cm2
0.2
438
935521
Rm. 07
B
Door
Wood
Stained
Intact
Negative
0.26
mg/cm2
0.25
439
935521
Rm. 09
A
Ceiling
Drywall
White
Intact
Negative
0
mg/cm2
0.02
440
935521
Rm. 09
A
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
441
935521
Rm. 09
B
Wall
Drywall
White
Intact
Negative
0
mg/cm2
0.02
442
935521
Rm. 09
B
Closet
Shelf
Wood
White
Intact
Negative
0
mg/cm2
0.02
443
935521
Rm. 09
C
Window
Sill
Wood
White
Intact
Negative
0
mg/cmc
0.02
444
935521
Rm. 09
C
Window
Casing
Wood
White
Intact
Negative
0
mg/cm2
0.02
0611612015 13:15 f P.0041004
i
Date.
plall
`
P&t
6 oral, Plumbing:
Litt m # City U.i
d
c4 A. R
a % i
OWNEWCONTRACTOR SIGNATIVRE Of UNDEMANDING AND AGREEMENT
,. ` t b .: t 4: is w i t h ♦• ` 4 t A t • •.. t t. t♦ t z: '. A t 5 R :: t t �i.:.
B i t
" t't t t i i. - :4M .t. i.. - si, '..t t t tr. % ! : • : i • t....t i
Mt t.. i ': *. .: t ♦' ♦... s ,I♦ t ! - a`;., t i... � t ii= 3 aR R : i ,:: t..' R b t
°i;,. `4 s t t. ^k •P=! ( '% S tk ": ftA : t % : f *"e.Ai �'. t
=♦ 4 Jmlz
Rovifte
%. ■ M t OOi tib i t
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: 44Ji r/,7 uviiu.� .JS
Job Address: 9 5;0,5
Permit Number: lO >32o
E7G7 aY S f A Tex wAVg;o " i; ?,lt " f-'>i/2 tdsL✓t�a�JS
❑ No one available for inspection: Time :S AM M
Re- Inspection required: E R No
* When corrections have been made, Gaff for re inspection at 303
Date: 7 is Inspector
7
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
r4000r uilding Inspection Division
(303) 234 -5933 Inspection line
235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: /3�� c /cri�a/ra�uo5
Job Address: >��ZS ,y, yFStrf /�yf sr0
Permit Number: f011®
❑ No one available for inspection: Time ff, A PM
Re- inspection required: Yes N '
"When corrections have been made, call for re- Inspection at 303- 234 -5933
Date: f/ /® Inspector:
DO NOT REMOVE THIS NOTICE
Cit �f
Y
COMMUNITY DEVELOPMEN
I
Building & Inspection Services Division
7500 W. 29 Wheat Ridge, CO 80033
Office: 303 -235 -2855 * Fax: 303 - 237 -8929
Inspection Line: 303 - 234 -5933
Building Permit Application
Property Address_ !• 29 5 W l /'� ✓{
Property Owner (please print) J C H f Phone
Mailing Address; (if different than property address)
Address:
City, State, Zip:
9000 ctor: W l evo 0 rN5 r'r^ Ctir L ✓I
Contractors City License #: Phone:
S Wli Contractors:
Electrical: Plumbing: Mechanical:
City License # /0-0140 City License # City License #
T3 o k i / 7 L„rnl0aw5
t`EQ(/jGE 5(NGt e AwAt t/.'s- 64**" c- Contract Value:
W wi jj'L_ birao L ¢
ir�Gaw Vf FrLs e -lev4GCY Gt rlfcievur
Review Fee (due at time of submittal):
Squares BTU's Gallons Amps Sq Ft: $
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants; easements or restrictions of record; that all measurements shown and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with applicable City of Wheat Ridge . codes and ordinances for work under any permit issued based on
this application; than am the legal owner or have been authorized by the legal owner of the property to perform the described work
and am also authorized by the legal owner of any entity included on this application to list that entity . on this application.
CIRCLEONE.' (OWNER) (CONTRACTOR). or (AUTHORLZEDREPRESE)Y TIVE) of (OWNER) (CONTRACTOR)
PRINT NAME: e4 a. L{/yVQf fli SIGNATURE: r DATE:
. � � ✓ , +� � ` ` " �� y „ ° d .
ZONING COMN(ENTS f . r- - a -.=-s -"a 'a. ✓—. ,..r`��✓ —✓ ,,-. ✓ r _ ✓ ,✓ ,_ '.
✓ z zO.JJ}n.9 "��j. `� �t� ✓' r a ��r ✓� `. ✓' ' ✓i✓✓ > .',.✓�✓ a� r_ i '�✓�,� rf? ;1 ay,+u'✓;
� � ReU10W2Y � s � i � h '�," ,✓� ✓�� � n 9 � e �� � r � y : ✓ � I
� j e r l / . yrs � � � ✓ e � �� � �✓ " ✓✓+' ��� � i�d� y ��� �� ri 4 �� ✓a✓
r $UILPING DEPART(�IEN7 COMM) =NTS �/ i : `"%" ✓ i � : j i ✓ ` z `' -
ReY18WeP ✓ �. ,,✓ � ✓ ✓ � . ,�" i al '✓ '`� � T �✓ P »yv v � ✓ l>
✓ ", /✓ � i ✓ do- j . r c� ✓ � !' , ✓ �, � ✓ +-. -.
r -c �. t. _✓ a ✓.. 1j -S �'F a } 4„" !
tPU6LIC WORKS COry7MEpTS. ✓' ^"" r -r �`✓ r ssyz � 1 4CCUPANCY
� ReVlewer �� . l ,✓i :. A � % ✓�'� � / �� �`° a y sv ¢ :�,
'FIRE REPARTMENT" ❑ approYe�ivl comments fi7 �ISapproved D J19 rewew,�Ye�Glred ; Bldg Valuation $
e ® ! s CITY OF WHEAT RIDGE
Building Inspection Division
d (303) 234 -5933 Inspection tine
(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: sue.
Job Address:
Permit Number: /D tJ <°
7
❑ No one available for inspection: Time AM /PM
Re- Inspection required: Yes No
,a
When corrections have been made, call for re-inspection at 303 -234 -5933
Date: z O Inspector:
DO NOT REMOVE THIS NOTICE
City of
Wheat idle Date:
~MU.NiTY DEVELOPMENT ~~jjj Pennrt j C~~~
Building Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 " Fax: 303-237-8929
Inspection Line: 303-234-5933
Facsimile, Building Permit Application
Property Address; gQgS (,v, 4h Avio
Property Owner (please print): ~t is(►1Q `~1 (-f j, Phone.
Mailing Addrr~~ss: (if different than mperty address)
Address:Ilai2ir) t,-% fl~1ti W,,,o.
Contractor:
License#: (-)I f `X%SS - Phone: ~j~ 11 cJd -
Sub Contractors:
Company Nome; License M Expiration Pate: Trade/Profession: Approval:
Use of sppace (description): Mno J K.,,T l~1;rb
Description oTw``ork:
Nu, ('ePl0.C4h•ev~k' . Plan Review (due at time of subm0aq: S
Sq. Ft./L Ft added' Squares BTU's 143-46-N Gallons Amps
OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (La.C) and all other applicable Wheat Ridge ordinances, for work
under this permit. Plane subjectto field Inspection.
C/RLCEONE;: (OWNER) CONTRACTOR or PERSONAL RE SEN TI i(OWNER) (CONTRATOR)
PRINT NAME: ar1tmi SIGNATU Date; q-as-lc
ZONING COMMENTS:
Zoning;
Reviewer.
PUBLIC WORKS COMMENTS:
Reviewer;
DEPARTMENT USE`BNLY
BUILDING DEPARTMENT COMMENTS: OCCUPANCY:
Reviewer.
FIRE DEPARTMENT.; O approved w/ comments ❑ disapproved in no review required- Bldg Valuation: $
Credit Card P yment: Use credit card listed on file% Da _ -lC7
Print name: ,-e I_C4rrl~LgyL Signaturqi,_
♦ 4 i CITY OF WHEAT RIDGE
"~-j Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 235-2857 Fax
INSPECTION NOTICE
Inspection Type: M-R7?,*1 A-Q~o IIV. _2P
Job Address: 1,-.1 ~V;-/a , ~
Permit Number: _'~6559'7
2
❑ No one available for inspection: Time AM/PM
Re-Inspection required: Yes No
When corrections have been made, call for re-inspection at 303-234-5933
Date: Inspector:
DO NOT REMOVE THIS NOTICE
0
3
a
0
yoH
~ ^OZ
o mom
mm 300y u
m~ ma
x~ naa~ 'm
my o3md
n mcR $
oa D as o
a6 my Sry
n~ yV N O J
P3 <
ymmN <
3 O- Om c
m °00?1~ o
7
y ?L7c3 d
al gF o
n osm 0
C Ury j
< A-w o
N
H~o
N
1n'a.d N
3m° oW
j dGz
T,~m rv
m
o>fyr
R-
.0-'3
°0F3
o.ss
niON~
ws~~
m~.0
zo
3y,m
m w~
II
0 ^c
m°pm
yF j~
~N w^
dm0y
°2 T16
6S n
wTT3~
o
w_O
9192 S
o2Km
vem3
m s w.
mm y?.
0000
Q 'aF
dn~3.
O
oa=
g=.
S
ma;cm
,~som
w~a
Oy10
~
Od0 _w
Gay
o^w>>
~m5
W N MR,
FPmdom3n~ O3c w" C1
Oc d
o no Fnm~mo`0 rvmm
nv~~ro.~n_ omw_.
w _
m m3,o m~'g°i'o'd- 0-0
x
om° m ¢mwF"m<.m E 3 Z
aOl
mII w~..ym^ msm W.
mo nFy~amo ~6~,~m9
3xam d,nob 5Z0
vOZ czn
3 wN PmII~°°~ w3~ ~0+~
'J d~m~Ny~C.nC YmiyN HOC
9 NO=F O'mFN w.~ ;m
d'°=mc mn°-tn'o m mD
o^ro w'.0g-s om. 0c 0 m
yo3a.9.t^3m Via. ~
=~c°o~D
nOm O~° d m
T
m a
3 Pm^
n c'0^^>0o $ P
n ~O
F~m,0OTmo ny `G
v y~xo
y ~c't7oo mw0
m
131 ~O~yO-~ yd
NOmC^N G10 J O
n mQSoE~nv ~P
u cQs'i t001pN ].0-.
0 o<o n~oo o'y 1no
O
3 n
J OJ J T A q
0--0J OK> NO O.S 4y
m. p<,w 4o
1 p, ~.~0 NNW ~ wlwO^m
1 Pjyd Jdy y ~ d
i .9O o nF mm o-
ma~.o Sao o Tc cs
I ~mO
amro `pow m pm oN
f F~'dP Om O m m
a oo P g
m» mn n m
d 6» p~
d°O d O N
OR y w J
n y0 O N
c M.z v~ v
yF oG c
SO
j 190 ) 3
nDw OD v
S~F mo° o.
E a
^m
X
IIN
mm
sm
~m
m
0
ma m
mO r
N
^ c
o
'
mmny
a'
,vy
m
mdm
nm
m
9
@
s
w
Acp
s
x
9
o
=
=oMc
cma
o
np`ma
m
o=O
m
ov
GAZ
C
w3
do
m
m
.:Em
OR
00
w-y
3m
3m
mdm
On
at
6
dry
Ln
N
'
E3m
6
a
-
my
m
ma
y
j"'O.
sn
w41
m
mew
oP
m II
yd
do
n6
sw
n1
°m
yZ
m
m
BE
~my
R
,g
H3. e~
-
mm
c
J y`
y
iG0
~6
N 3
N
~w
O&M
0w
p~
.6-
off=
QN
EP3
mw
-RI
o
m
m
Om
°v
c
Dom
~m
m
wto
ca
3
NP~l
~m
NS
qa
mm
O
mm
p
»s
O
F
m10
Jy
fD
ON
m N
fpm
w
n
m
a-.
ma
d
n
OA
~d
3y
~o
>
m~
HN
m
o n
r0
9
mm
o
S
m
O
o
r
n
mo
o
m
-Jlpp.W SNm -1 n a v o
D ~I [Am ZO sm = m a m o
n=wwm's msz m 0 m m T m
y mw Nio <°oG1 a O o i m
3 mac~0 _.w D~ p m
m ~
m
w T
m
O
O
m
N
o m, n
m m0TD
DO 000
D
3m ooh
De xv Zo
dNL)
03D
II VT
s
m mc
neaw
063
NN
9:9 Om
006
N O
m mn
:ma >m
0
DQN 230:
n=. w-
3-
0 O
o
c SOO
:oy .00-
am mo9
y m
w t.P
2 0c
'0- m
'2 y°2
oc "Ps
c_ .9.
1nN .c
.MF
oa ~SO
u_,O Oda
3
0O r z"
HO
^.m 0Fm
~3 "
cw5
o~ w°w
yF
w
m yNz0 D
~T
na o
mo0
9x ss~.
mm
m
0
0
T
z
c~
n
O
0
z
m
O
z
'D
Gl
z
m
a
y
y
t
O
I
z
o
m
s
m
i
Z
O
N
O
b
m o
a
y w
N
N
pppq~L
m
y
g
8
g
W
a
m
z
0
m
O
0
m0
m
a
O
D
m
9
D
H
3
m
H
V!
F
z
m
m
m
y
0
0
yC
C
O
N
e
0
mm
C
a
O
O
09
a~
O
mm
~D
O
ZN
7}
Cl
^'V
Z
N
O
O
A
♦ A ♦ CITY OF WHEAT RIDGE
,-V,
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 235-2857 Fax
INSPECTION NOTICE
Inspection Type: Pali d°'
Job Address: 7,?YS k,+. Yg'5, w.rel
Permit Number: r9?n 5'9;r
r ArP c ti 10t4) nsair, . ~e saae~ l=
a1e11 770nj ,Peg ee/e9
.fig i 4-av sd 4w or ~?f~ 6?Gn_.~aa> s uar!/
anarea~ ssrme~F cs~ l~s ~~nr3~E~
~r
_<040 49C7-
AQ2.2 14d /41 , 7
❑ No one available for inspection: Time AM/PM
Re-Inspection required: No
"When corrections have been made, call for re-inspection at 303-234-5933
Date: /✓e%'9' Inspector:
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
r Building Inspection Division
1 (303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 235-2857 Fax
INSPECTION NOTICE
d ✓n1S6?
Inspection Type: F4AR7"1,4'1
Job Address: 7;27,` Et,, ~9711 fcrs6 .SAW
Permit Number: 417~c 5P7
m eF_ f w fps/>'~ iacd jew &,4*0
rz~¢ u~~ co al ~a r~ i JL &Ye.
g.
t, ❑ No one available for inspection: Time 11,,7P AM/PM
r-
y Re-Inspection required: Yes No - Es rid,~smJ
When corrections have been made, call for re-inspection at 303-234-5933
~I ~
j Date: 6,1571091 Inspector: 1~/°
i
DO NOT REMOVE THIS NOTICE
t;
City of Wheat Ridge
`
Commercial
Roofing PERMIT -
090587
s
PERMIT NO: 090587
, ISSUED:
06/02/2009
'
JOB ADDRESS: 9295 W 48TH AVE N
zEXPIRES:
11/29/2009
DESCRIPTION:... T/0
resheath, 4 plies
of fiberglass felt & gravel
CONTACTS
owner 303/422 8600
Jeffco Housing Authority
sub 303/295-77G9 Robert Tichy
01-7911 Alpine Roofing Co.,.:: Inc.
x
P
PARCEL INFO
ZONE :CODE: UA
'USE: UA
SUBDIVISION: 0044
`BLOCK/LOT#: 0/
FEE SUMMARY
ESTIMATED PROJECT VALUATION: 60,275.00.
u,
FEES
Permit Fee !
937.05
-
Total Valuation
.00 L~h{"LY7IF
Use -Tax
-
1,084.95
TOTAL
2,022.00
~y
Conditions:
r
Subject to field inspections.
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable
"
ordinances, rules or regulations of the City of Wheat
Ridge or covenants, easements or restrictions of record; that all
measurements shown, and allegations made are accurate
; that I have read and agree to abide. by all conditions printed on this
gnature of contractor/owner
e
t forth in your
and is subject to the. laws of the
orado or any'. other applicable
be received :prior to expiration
normally required, provided no
pension or. abandonment has not
ne (1) year,t full fees shall
a drainage problem.
11 inspections and shall receive
b`.
date
~oF W"s^^qo City of Wheat Ridge Building Division
~m 7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 " Fax: 303-235-2857
c o inspection Line: 303-234-5933
OLORP~
Building Permit Application
Date:
Plan
Permit CI Pr
Property Address; 9295 West 48th Ave., Wheat Ridge CO
Property Owner (please print): Jefferson County Housing Authority Phone: 303-422-8600
Mailing Address: (if different than property address)
Address: 7490 W 45th Ave
City, State, Zip: Wheat Ridge CO 80033
~ontracto: ALPINE ROOFING CO., INC
Contractor License 17911 Phone: 303-295-7769
Su6Contraefbrs
Electrical City License Plumbing City License Mechanical City License
Company: Company Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
Use Off s ace (descrtion): Apartment Bldg Construction Value: $60,275.00
'~@SCTIPOn_Of W07, 95 Squares -Tear off the exising roofing (as calculated per the Building Valuation Data sheet)
install tapered insulation, 1/2" cover board, 4 plies of fiberglass Plan Review (due at time. ofsubmittaq: $
felt, and. gravel, including misc sheet metal
Sq. Ft./L. Ft added: Squares "I v,l . BTU's Gallons Amps
OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I. hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances;
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to field inspection.
CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR)
PRINT NAME: ROBERT D. TICHY, PRESIDENT. SIGNATURE: Date: 611/09
Z. qrtlcle Number
or
7160 3407, 9644 2844 2813
3. Service Type CERTIFIED MAIL
4. Resirictetl Delivery? (EMre Fee) 1. Anicle Atldressetl to: ~~Yes
Re: 9295 W. 48th Ave.
X ~W j~v"z
u. is tlalivery atltlrass tliflerent irom den
I~ YES, enter delivery atltlresy pelm¢
Jefferson County Housing Authority 6025 W. 38th Ave.
Wheat Ridge, CO 80033
l ~ ~oOs
\ .
917, July 2001 Domestic Return Receipt
- • A ~ .
aF WHEql 7160 3901 9844 2844 2813
0
o m SENDERS • ' .
~~l ORA~
NOTICE AND ORDER
To
PROPERTY OWNER AND ALL CURRENT OCCUPANTS
Pursuant to the 1997 Edition and the Uniform Code for the Abatement of Dangerous
Buildings, the 1997 Uniform Housing Code and the 2003 International Property
Maintenance Code, the following property is in violation. According to County Records
you are the property owner of the described property in violation.
Apri15, 2005
Property Owner: Attn: Jefferson County Housing Authority
6025 W. 38`h Ave.
Wheat Ridge CO, 80033
Property Description: 243800 F'ICCO SUB or commonly known as: 9295 W. 48th v`
Stfeet.
Unit B-2, Wheat Ridge Colorado 80033
NOTICE
The property owner, and all current occupants, are hereby notified that the undersigned
Building Official of Wheat Ridge, Colorado, has found the building located on the above
described real property to be a Dangerous Building within the meaning of Section 302 of
the Uniform Code for the Abatement of Dangerous Buildings, 1997 edition, as adopted
by the City of Wheat Ridge, Colorado ("Code"), as more particularly set out below:
The building is being used for dwelling purposes and is in violation of the Uniform Code
for the Abatement of Dangerous Buildings, sections in bold are the sections that this
property is in violation of.
SECTION 301- GENERAL
For the purpose of this code, certain terms, phrases, words and their derivatives shall be construed as
specified in either this chapter or as specified in the Building Code or the Housing Code. Where terms are
not defined, they shall have their ordinazy accepted meanings within the context with which they are used.
We6ster's Therd new International Dictionary of the English Language, (Inabridge, copyright 1986, shall
be construed as providing ordinary accepted meanings. Words used in the singular masculine gender
include the feminine and the feminine the masculine.
BUILDING CODE is the /nternational Code Council, as adopted by this jurisdiction.
DANGEROUS BUILDING is any building or structure deemed to be dangerous under the provisions of
Section 302 of this code.
HOUSING CODE is the Uniform Housing Code promulgated by the In[erna[ional Conference of building
Officials, as adopted by fhis jurisdiction.
INTERNATIONAL PROPERTY MAINTENANCE CODE is the 2003 International Property
Maintenance Code promulgated by [he International Code Council, as adopted by this jurisdiction.
SECTION 302 - DANGEROUS BUILDING
For the purpose of [his code, any building or struc[ure which has any or all of [he conditions or defects
hereinafrer described shall be deemed [o be a dangerous building, provided [hat such conditions or defects
exist to the extent [hat the life, health, property or safety of the public or i[s occupants are endangered.
1. Whenever any door, aisle, passageway, stairway or other means of exit is not of sufficient width or
size or is not so artanged as to provide safe and adequa[e means of exit in case of fire or panic.
2. Whenever the walking surface of any aisle, passageway, s[airway or other means of exit is so
warped, worn. Loose, [orn or otherwise unsafe as [o no[ provide safe andadequate means of exit in
case of fire or panic.
3. Whenever the svess in any ma[erials, member or portion thereof, due to all dead and life loads, is
more than one and one half times the working stress or svesses allowed in the Building Code for
new buildings of similar structure, purpose or location.
4. Whenever any portion thereof has been damaged by fire, ear[hquake, wind, flood or by any other
cause, to such an ex[ent [hat [he sUuctwal sVeng[h or s[ability [hereof is ma[erialty less than it was
before such catastrophe and is less than [he minimum requirements of [he Building Code for new
buildings of similar struc[ure, purpose or location.
5. Whenever any portion or member or appurtenance thereof is likety to fail, or co become detached
or dislodged, or to collapse and thereby injure persons or damage property.
6. Whenever any poRion of a building, or any member, appurtenance or ornamentation on the
exterior thereof is not of sufficien[ svength or stability, or is not so anchored, attached or fastened
in place so as to be capable of resis[ing a wind pressure of one half of that specified in [he building
Code for new buildings of similar struc[ure, purpose or location wi[hou[ exceeding the working
sVessed permitted in the Building Code for such buildings.
7. Whenever any portion thereof has wracked, warped, buckled or settled to such an extent that walls
or other svuctural portions have materially less resistance to winds or earthquakes than is required
in the case of similar new consVUCtion.
8. Whenever the building or structure, or any portion thereof, because of (i) dilapidation,
deterioration or decay; (ii)faulry construction; (iii) the removal, movement or instability of any
portion of the ground necessary for the purpose of supporting such buildings; (iv) the
deteriora[ion, decay or inadequacy of its foundation; or (v) any o[her cause, is likely [o partially or
completely collapse.
9. Whenever, for any reason, the building or structure, or any portion thereof, is manifestly
unsafe for purpose of which it is being used.
10. Whenever the exterior walls or other vertical svuctwal members list, lean or buckle to such an
extent that a plumb line passing through [he cen[er of gravi[y does no[ fall inside the middle on
third of the base.
11. Whenever the building or strucmre, exclusive of the foundation, shows 33 percent or more damage
or deterioration of its supporting member or members, or 50 percen[ damage or de[erioration of i[s
non-supporting members, enclosing or ou[side walls or coverings.
12. Whenever the building or structure has been so damaged by fire, wind, earthquake or flood, or has
become so dilapidated or deteriorated as ro become (i) an attractive nuisance ro children; (ii) a
harbor for vagrants, criminals or immoral persons; or as to (iii) enable persons to resort thereto for
[he purpose of commi[ting unlawful or immotal acts.
13. Whenever any building or structure has been coustructed, exists or is maintained in
violation of any specific requirement or prohibition applicable to such building or structure
provided by the building regulations of this jurisdiction, as specified in the Building Code or
Housing Code, or of any law or ordinance of this state or jurisdiction relating to the
condition, location or structure of buildings.
14. Whenever any building or s[ruc[ure which, whether or not erected in accordance with a alI
applicable laws and ordinances, has in any non-supporting part, member or portion less than 50
percen[, or in any supporting pazt, member or portion less [he 66 percent or the (i) strength, (ii)
fire-resisting quali[ies or characteristics, or (iii) wea[her-resis[ing qualities or characteristics
required by law in the case of a newly constructed building of like azea, height and ocwpancy in
the same location.
15. Whenever a building or sVUCture, used or intended ro be used for dwelling purposes, because of
inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangemen[,
inadequate light, air or sanitation facilities, or otherwise, is determined by the health officer to be
unsanitary, unfit for human habitation or in such a condi[ion that is likely ro cause sickness or
disease.
16. Whenever any building or structure, because of obsolescence, dilapidated condition, deterioration,
damage, inadequate exists, lack of sufficient fire-resistive cons[ruction, faulty elecVic wiring, gas
connections or heating appaza[us, or other cause, is de[ermined by [he fire marshal ro be a fire
hazard.
17. Whenever any building or structure is in such a condition as ro cons[itute a public nuisance known
to [he common law or in equity jurisprudence.
18. Whenever any por[ion or a building or shacture remains on a site after the demoli[ion or
destruction of the building or sVUCture or whenever any building or s[ruc[ure is abandoned for a
period in excess of six mon[hs so as to consti[u[e such building or portion thereof an attractive
nuisance or hazazd [o [he public.
The 1997 Uniform Housing Codes states;
SECTION 1001 -DEFINITIONS
1001.1 General. Any building or portion thereof that is de[ermined ro be an unsafe building in accordance
with Section 102 of the Building Code, or any building or portion thereof, including any dwe]ling unit,
gues[ room or suite or rooms, or the premises on which the same is located, in which there exists any of the
conditions referenced in this section ro an extent that endangers the life, limb, health, property, safety or
welfaze of the public or the occupants thereof, shall be deemed and hereby are dulared ro be substandard
buildings.
1001.2 Inadequate Sanitation. Buildings or portions thereof shall be deemed substandazd when they are
when they are in sanitary. Inadequate sanitation shall include, but not be limited to, the following:
1. Lack of or improper water closet, lavatory, bathtub or shower in a dwelling unit or lodging house.
2. Lack of or improper water close[s, lavatories, and ba[htubs or showers per number or guests in a
hotel.
3. Lack of or improper kitchen sinlc in a dwelling uni[.
4. Lack of hot or cold running water [o plumbing fixtures in a ho[eI
5. Lack of hot or cold running water [o plumbing 5xtures in a dwelling uni[ or lodging house.
6. Lack of adequate heating facilities.
7. Lack of or improper operation or required ventilating equipmen[. 8. Lack of minimum amounts of natural light and ven[ila[ion require by this code.
9. Room and space dimensions ]ess [han required by this code.
10. Lack of required elecvical lighting.
11. Dampness of habitable rooms.
12. Infestation of insec[s, vermin or roden[s as determined by the health officer.
13. General dilapidation or improper maintenance.
14. Lack of connection to required sewage disposal system.
15. Lack of adequate garbage and rubbish s[orage and removal facilities as determined by the health
officer.
1001.3 Structural Hazards. Buildings or portions thereof shall be deemed substandard when they are or
contain structural hazards. Structural hazazds shall include, but not be limited to, the following:
1. Deteriorated or inadequate foundations.
2. Defective or deteriorated flooring or floor suppor[s.
3. Flooring or floor supports of insufficient size to carry imposed loads with safety.
4. Members of walls, partitions or other vertical suppor[s that spli[, lean, lis[ or buckle du ro defective
material or deteriorations.
5. Members of walls, paRitions or other vertical supports that are of insufficient size [o carry
imposed loads with safety.
6. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that sag, split
or buckle due to defec[ive material or deterioration.
7. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members that are of
insufficien[ size to carry imposed lads with safety.
8. Fireplaces or chimneys that list, bulge o settle due to defective material or deterioration.
9. Fireplaces or chimneys that aze of insufficient size or sVength to carry imposed loads wi[h safety.
1001.4 Nuisance. Buildings or portions thereof in which there exists any nuisance as defined in this code
aze deemed substandard buildings.
1001.5 Hazardous ElecVical Wiring. Electrical wiring that was ins[alled in viota[ion of code requirements
in effec[ at [he time of installation or elec[rical wiring not ins[alled in accordance wi[h generalty accepted
consvuction practices in areas where no codes were in effect or that has not been maintained in good
condition or that is no[ being used in a safe manner shall be considered substandard.
1001.6 Hazazdous Plumbing. Plumbing that was installed in viola[ion of code requirements in effect a[ the
time of installation or plumbing not installed in accordance with generally accepted construction practices
in ueas where no codes were in effect or that has no[ been maintained in good condition or that is not being
used in a safe manner shall be considered substandard.
1001.7 Hazardous MechanicaL Mechanical equipment that was installed in viola[ion of code requirements
in effect at the time of installation or mechanical equipment not installed in accordance with generally
accepted construction practices in areas where no codes were in effect or that has not been maintained in
good condition or that is not being used in a saFe manner shall be considered substandard.
1001.8 Faulty Weather Protections. Buildings or portions thereof shall be considered substandard when
they have faulty weather protections, which shall include, but not be limited to, the following:
1. Deteriorated, crumbling or loose plas[er.
2. De[eriorated or ineffective waterproofing or exterior walls, roof, founda[ions or floors, including
broken windows or doors.
3. Defective or lack of weather protec[ion for exterior wall coverings, including lack of paint, or
wea[hering due to lack of paint or other approved protec[ive covering.
4. Broken, rotted, split or buckied exterior wall coverings or roof coverings.
1001.9 Fire Hazard. Any building or por[ion thereof, device, appaza[us, equipment, combustible was[e, or
vegetation [hat, in the opinion of the chief of the fire department, is in such a condition as ro cause a fire or
explosion or provide a ready fuel [o augment the spread and intensity of fire or explosion azising from any
cause shall be considered substandard.
1001.10 Faulty Materials of Construction. The use of materials of consvuction, except those that aze
specifically allowed or approved by [his wde and the Building Code, and [hat have been adequately
maintained in good and safe conditions, shall cause a building to be substandard.
1001.11 Hazardous or Insanitary Premises. The acwmulation of weeds, vegetation, junk, dead organic
matter, debris, garbage, offal, rat hazborages, stagnant water, combustible materials, and similar materials
or conditions on a premises constitutes fire, health or safety hazards that shall be abated in accordance with
the procedures specified in Chapter 11 of this code.
100112 Inadequate Exits. Except for those buildings or portions thereof that have been provided with
adequate exit facili[ies conforming to the provisions of this code, buildings or portions thereof whose exit
facilities were installed in violation of wde requiremen[s in effect a[ [he time of [heir construction or whose
exit facilities have not been increased in number or width in relations ro any increase in occupan[ load due
to alterations, additions or change in use or ocwpancy subsequen[ ro the time of construction shall be
considered substandard.
Notwithstanding compliance with code requirements in effect at the time of their consvuction,
buildings or portions thereof shall be considered substandard when the building official finds that an unsafe
condition exists through an improper location of exi[s, a lack of an adequate number or width of exi[s, or
when other condi[ions exist [ha[ are dangerous to human life.
1001.13 Inadequate Fire-Protection or Fire-Fighting Equipment. Buildings or portions there of shall
be considered substandard when they aze not provided with the fire-resistive construction or fire-
extinguishing systems or equipment required by this code, except those buildings or portions thereof that
conformed with all applicable laws at [he time of their construction and whose fire-resis[ive in[egrity and
fire-extinguishing sys[ems or equipment has been adequately maintained and improved in relation ro any
increase in occupant load, alteration or addition, or any change in occupancy.
100114 Improper Occupancy. All buildings or portions thereof occupied for living, sleeping, cooking or
dining purposes that were not designed or intended ro be used for such ocwpancies shall be considered
substandard.
The following is a list of items that shall be fixed to meet code:
✓ The apartment unit shall be gutted to get out the smell of smoke.
✓ If sheet rock is removed then wiring and plumbing that is exposed shall be
brought up to code.
✓ All items that have been modified shall meet code 2003 IBC.
✓ Smoke detectors shall be hardwired in with battery back up.
✓ City of Wheat Ridge Building permit shall be pulled before any demolition
begins.
ORDER
The City of Wheat Ridge Building Official has determined the building referenced above
to be a Dangerous Building and to constitute a health hazard if not fixed. The owners are
ordered to pull a building permit to fix the deficient items. Pursuant to Code tenants shal]
not be permitted to occupy this units until all issues are brought up to code and are
inspected by the City of Wheat Ridge Building Department. This is therefore required in
order to protect life, health and safety of the public.
The property owner and all future occupants are hereby ORDERED TO CEASE
AND DESIST occupancy and use of the above described building. The Building
Official shall cause the property to be posted with the attached Notice and shall take
action to remove a11 future occupants from the building.
REMEDIAL ACTION
1. The property owner must apply for and obtain a City of Wheat Ridge building permit
to correct the following deficiencies.
1. All deficiencies shall be fixed but aze not limited to the items on this list.
APPEAL OF THIS NOTICE AND ORDER
Any person having record title or other legal interest in the above described premises may
appeal this Notice and Order or any action of the Building Official to the Board of
Appeals pursuant to section 205 of the Code, provided that the appeal is made in writing
as provided in the Code and filed with the Building Official within ten (10) days from the
date of service of this Notice and Order. Failure to appeal will constitute a waiver of all
rights to an administrative hearing and determination oF this matter. FILING OF AN
APPEAL SHALL NOT STAY THE EFFECTIVENESS OF THIS NOTICE AND
ORDER.
It is a misdemeanor to occupy this building, or to remove or deface this notice.
BY ORDER OF THE CITY OF WHEAT RIDGE'S BUILDING OFFICIAL
303-235-2853
303-570-7510
Chadley Root, Building Official
Property appraisal system
Previous 5 OF 24 Next
Page 1 of 1
IISch:085144 Parcel ID:39-153-16-005 Status:Exemnt Pronertv Tvne:Exemrotl I
W 48TH AVE
kT RIDGE CO 80033
W 38TH AVE
kT RIDGE CO 80033
Name
COUNTY HOUSING
sion Name: 243800
Date
Location Map/Additional Information
Send mnil to nssessoi@cajeCferson.co.us with questions or wmments about this Web site.
Copyright @ 2004, Jefferson County, Colorado. All righ[s reserved.
A Map of Ho_w to Get to Our Office
Web site infolmation current through:04-0?-?005
Version 322 - Release Dare: Dec 2004
http://wwl4.co.jefferson.co.us/ats/displaygeneral.do?sch=085144&offset=4 4/5/2005
Home C:eneral
prop9fty, Ft~~r~ds Iaiform.~i#it~n
Y.`Building Permit
CITY OF WHEAT RIDGE
7500 West 29TH Avenue
. Wheatridge, CO 80033
, 303-235-2855
Cilyo(VMzattuye
Permi[ Number
18972
7/13/2005
r Inspection Line
303-234-5933
Residential Miscellaneous
!PROPERTY 9295 48th AV Ullll: pJ 1
QWNER: Jefferson County Housing Authority (303) 422-8600
:Deseriptiou
Fice ROStocation: replace drywall, repair elect., repair plumbing, ceplace 1 heat register, replaee 1 window.
_ I..
Due
_ ~$.00
I$.00 _
[Paid _I
tS
~Uaiht~Occupancy: Walls: Roof: Stories: SqFeet: 0
[ hbabymlify Nrt Ne setback Jislnnccs propased by Ihis permil appLcatlon ere aaunt4 antl da nol violale appYCable oNmances, rvkv or regula4om o(fhe Gry af
I WYUtRiB[toreoveomm, e.xmente or rnln<aon. ofrcrord, [hat all mevsunmenls showq vnd allegafons made nre aauratt.luet 1 ha.'e revtl and+grn la abide by
1tl {oMltlppe prinhd on tM1is appLwfbw, and eM1nl l nssume full respnnsibllily for cumpllaocc mth ihe WM1em RiJge BuJdmg Cada (U.B C.) nnd nll olher apPlicable
~ Whep rdinmca,forwarkun ' ermtl. s
o sIcrvEn nare
1 7ys permHwanesuedinvmorJancewtlM1thaprovtsionsx1 furthinyourapplicvtlonandissubject roIM1ebwsoftheSmaeo(ColondaenArodoeZoning
IqeditlonemJfluikingCOdeo(WhealRidge,ColarvtloornnyolhvapphcableordmencevofdM1eCiry.
' 3 ,1%1epermitsha0<xyirei[(A)theworkeuthodu0ienalcommeneedwhM1insixty(60) tlaysfromissuetlehor(B)IM1ebuildingnutborizeJBSUSpmdedor
.:`.d+naoomm, .n<.maon:oaays.
D .IhWpermitexpiref.anewpermummbeacquireJfar. feeofoneM1nl(1heamounlnormvllyrtqukeJ,providednochangeshnvebnnorwNbemadcmMe
oel(4ulpluwandspecNuhoneantlnnymsprnslo^orabvnJanmenthesmtexceedeeone(1)yenelfchnngesarematleonfsuspensiooorabvn0onmmt
eseeed, om (q yevq PoII fees shall bc paiJ far a new permit.
4.No MOrkohnymmnersM1allbeJOmthat wNahangethenvNnlOOwafwattra.usingvdrallnvgeproblem
S CMtraftor fhW mlify the Bu110ing Insyeawr Iwmry-four (24) honrs m advnnce for all iveyeatlons vnd shnll recdve wntlen npprovvl on inspecuon wN be6re
p(uudin hmacoerve eua[t~Jab.
~
6 af ~carlbeapP~^velaf ingsvndspeci0evliansfhvllsmlbeeonsvuMlobeayenm[far,noranapprovalof,nnyvlolationoftM1e
ml~od olherordmance,law ruleorregulaUUn
C61ef]olWio( Wpector $IGNED DATE
,:WedneYday, 7uly 13, 2005 Page 1 of 1
Building Permit
CITY OF WHEAT RIDGE
7500 Weat 29TFI Avenue
Wheatridge, CO 80033
303-235-2855
Cily af 4iheat F3dge~ I
Permit Number
18972
7/13/2005
Inspection Line
303-234-5933
Residential Miscellaneous
PROPERTY 9295 48th Av Unit:
owNea: Jefferson County Housing Authority (303) 422-8600
Description
Fire Restoration: replace drywall, repair elect., repair plumbing replace 1 heaY register, replace 1 window.
Authorized By guilding Approval Zoning
Authorized On Approved By CR
Must meet 2003 IBC, 2002 NEC
Wednesday, July 13, 2005 Page 1 of 1
COMMUNITY DEVELOPMENT DEPARTMENT Building Pertnit Number:
a'""f+T BUILOING INSPECTION UNE - 303-234-5933 Date:
° °a CITV OF WHEAT RIDGE
~ ^ 7500 WEST 29TH AVENUE
WHEAT RJDGE, CO 60033 - (303-235-2855)
~o~«~.~ APPLICATION
- rroperrY owner: .
rnoot: 3cie AfzX-BGCnntxs
PropcrtY wadress: g
Conaactor Liccnse No.:
Pbone' ~03 yJ37 -07/~(l~.Z! t
~~y:
co
pWNEWCONTiUCTOR SIG7UTURE OF UNDERSTANOING AND AGREEMENT Buildina Dept Valuation Figure:
1 hereby ceAifY that the SetDack distances MWoSOO bY Mis Pemit appfication are
accurate. ard do rwt violate aPWicaDk aanances, rules a repuWtions of the Ciry ot
Wheat Ri(ipe a oovenants. easertients a restricGOns of record: Cwt all meawremd"
shown. ard aNeflauons made are aau2le: tlwt 1 have read and aGree to abide bY all
conditions Mi^ted on this appliwtion and that I aswme wu resv«+siaxry ta
compiiance with the W heat Ridpe &ri1d+rW CoOe (I.B.C) an0 aN Wher aPPlicable Wheat
Ridpe Ordinances, for work un0a this permil. Plans subject to fieW inspec0on.
DATE7"~
(OW NFRNGONTRACTOR). SIG
Onh
(OW NEi1)(GONTfiACTOR):P1iNRED
Value:5 ~a
/
Permit Fee:$ ~ ~
Plan Reviewce Tee:S~~° ~
Total:$
lfse of Space (description): Desc_ ^ ~pticnif~ q~p77 ~,~i~~~ ~w~~mcFiA'u~t~'a~' `u~uii t~P"c~
it~aor~a`~u. - ' l
V
SQ.Ft.added r' 0
BUII.DING DEPARTMEI`17' USE ONLY SIC: Sq.FI:
WING COIMAENTS:
qpproval:
Zoniry:
Cify vf Wheat Rid e PRESCRIPTiVE ENER Y t~ 200§
maNCCOw+ewTS.
BOILERS : FURNACES A MINIMUM OF 90% FUE
Mu~~~ Qp$ WATER HEATERS A MINIMUM OF.60 ENER- _
a
LECTRIC WATER HEATERS A DAINIMUM OF.93 ENERGY FACTOR
SFG
~
3
+eNTS:
Cau
~
$ETBACK THERMOS'CAT REQUIRED (EXCEPT HYDRONIC HEAT)
.
aKs
jeucwo
Approval:
R.21 yypLl.S • R-38 CEILINGS • R•19 CRAWISPACES
Deo,wnWM CawMENrS:
qpppvai:
yyalls; Roof:
t~i t~~ ~ Plumbing License
EfectncaI L'wense C~ Grt~. °
Company. A Company.
Expiration Date: Exp~p~ir~aytion Oate:
w.....ma~l• ' T~' _ _ _ .
Stories: Residentiai Units:
Mechanical L'icense
' Company.
~
~
Expiration Date:
dsnoe wM the P~^~^s ~ IoM in your appGraUOn arW is wbjea b the laws ot tne State of
(1) 7Tis P~ was iuued in xaor
Cp1"dp and b Mx ZaWq Repulsoaa ard BuiW'mG Codes d Wheat RiOpe. Cdaado a anY otlw oVdicable ord'mances of
Me CeY• atuY e~ro d(A) G~e work auUwrmed is nd commenoeC ~hv~ sintY (90) 0aYs fia" issue date a(8) the building
{2) Thau~ a wpsnded a ypyKiybp for a Geriod of 180 days.
(3) If tltia P~~ ~roE. a new D~^K ~^aY b° 1or a fee o1 ons-haM 1M arnourn normagN ro0uiieC. pwided no dha^9es
nave ceen wwiM De maas in n» oripinal WYW wo p°Otimcons arw anr wa0ermo^ °f oba'xw'mw" nas not exceeeed one
(1) Yege. H chypey havs bsen a H swDons°^ °f °bww0rwnwd O1ceeds one (1) Y'ear. tuB fees shall bs Daw iv a new Demril-
(4) No wak d anY ^urwW sha W Oais Uul vA d+rqs IM ruWrallbw d wabr mdrW a drairupe po61eni.
IM &idrq knD~ t+'~Y~r (24) ~m in advarws lor 91 ~ and aheR recerve writlen
ConVacbw (5) appmval Y~i~ps ~ db^ cord baiors Woopedr'0 wih wcosseiw Whass+ d IM job.
16) The is,uanw d a Dw" ar sw &vRoval ddr""""o° and °p°dkobons " na be ca,atrued m be a vwma tor. rwr an
appwal d. anY vblmlio^ d 1M Wovbb^° of tlw buNdmp ooEes w anY oCw adnanoe. Uw. mb v rePtlaOO^- N1 Wn rwMw
b wblect lo }Mid Mupw-Uom•
Chief BuiWing Official
Disaster Solutions
7130 West 16th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
Client: JCHA-Henry Wehrdt
Cellulaz: (303) 994-3034
Fax: (303) 422-8600
Property: 7490 W 45th Avenue
Businesx (303) 422-8600
Wheatridge, CO 80033
Operator Info:
Operator. DENNIS
Estimator: Dennis Newell Business: (303) 937-0717 x 1
r oi ~nea~ n '_"R~RIPTIVE ~NERGY
Business: 7130 West 16th Avenue gpILERS 1 FURNACES A MINIMUM OP 90% AFUE
Lakewood, CO 80214 a" yyATER HENTERS A MINIMUM OF.i0 ENERGY FACTOR
~ yyATER HEATERS A MINIMUM OF.89 ENERGY FACTOR
Type of Estimate: Fire ~ CK THERW sTAT REQUIRED (EXCEPT HYDRONIC FIEAT)
Dates: R-21 yALI,s . p41 CHIJM65 • R•19 CRAYrLfPAM
Date Entered: 04/29/05 Date Assigned: 04/06/05
Price List: MARCH2005
Restoration/Service/Remodel with Service Chazges
Factored In
Estimate: JCHACAESARSQUARE
File Number: 9295W48THAVE
Claim#A6TR8 ON SITE PLANS
Eagle Adjusting Services, Inc.
Adj: Brian Kramp
P. B°X'Z'° MUST BE ON SITE
Pazker, CO 80134
P,-,:303_805_1205
FOR INSPECTION
~WH~•>,,, CHIEF BUILDING OFFICIAL
Wheat Ridge BuildinqyDepartment
f ~,,./T • a
L
J LDING OFFI IAi. - DA1'E
validity of perm0: 76 iewanoe d a penmit a aDproval c( Plans, speaficatw^s
3nd tampulations shaN ial be a permit tor, a en approvel d, airy vblation to
any d Ihe provisions oi the ddldrg oode or d any City ordnances.
PBrmMs Oresuming Io give aulhaNy to vblale or cancel the provisians dtBe -
Iwildij wdes or other wdinances d the Ciry shaN not be valid.
Disaster Solutions
7130 West 16th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
Room: Living Room
JCHACAESARSQUARE
LxWxH 14'6" x 12'2" x 7'4"
R&R Door opening (jamb & casing) - 32"to36"wide - paint grade
1.00 EA
Interior door - Detach & rese[ - slab only
1.00 EA
R&R Carpet - Standard grade
176.42 SF
R&R Carpet pad
176.42 SF
R&R Carpet - metal transition strip
6.00 LF
R&R Acoustic ceiling (popcorn) texture
176.42 SF
Clean the walls - Heavy
301.89 SF
SeaVprime the walls - one coat (white pigmented shellac)
301.89 SF
Paint the walls - two coats
301.89 SF
Mask the walls per squaze foot
301.89 SF
Clean window unit (per side) 10 - 20 SF
1.00 EA
Clean baseboard heater
12.00 LF
Paint baseboard heater
12.00 LF
Clean exterior door (per side)
2.00 EA
Clean door / window opening (per side)
1.00 EA
Clean outlet or switch
6.00 EA
Clean thertnostat
1.00 EA
R&R Window screen, 1- 9 sf
1.00 EA
Clean and deodorize building - Ozone treatment
150.00 CF
R&R Smoke detector - High gade
1.00 EA
Waste Item - Carpet - Standazd grade
44.83 SF
Waste Xpert - Carpet Waste: The following cuts will produce the specified line item prices:
Cut #1 Room Name: Living Room Dimensions 14'9" X 12'0"
Cut #2 Room Name: Living Room D'unensions: 3'8" X 1'8"
Room: Kitchen
LxWxH 12'2" x 11'0" x 7'4"
Clean floor, strip & wax
R&R Fluorescent light fixture
R&R Ceiling fan & light
Clean cabinetry - upper - inside and out
Clean cabinetry - lower - inside and out
133.83 SF
1.00 EA
1.00 EA
20.00 LF
15.00 LF
JCHACAESARSQUARE 07/05/2005 Page: 2
Disaster Solutions
7130 Westl6th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
CONTINUED - Kitchen
R&R Coun[ertop - post formed plastic laminate
12.50 LF
Clean range hood
1.00 EA
Clean dishwasher
1.00 EA
Clean the walls and ceiling - Heavy
384.39 SF
Seal/prime the walls and ceiling - one coat (white pigmented shellac)
38439 SF
Paint the walls and ceiling - two coats
38439 SF
Mask the walls per square foot
250.56 SF
Sink - double - Detach & reset
1.00 EA
Clean sink
1.00 EA
Clean sink faucet
1.00 EA
Clean outlet or switch
6.00 EA
Clean kitchen accessory
1.00 EA
Clean range - Heavy
1.00 EA
R&R Refrigentor - 14 cf
1.00 EA
Clean and deodorize building - Ozone treahnent
150.00 CF
R&R Smoke detector
1.00 EA
Room: Hallway
Subroom 1: Closet
LxWxH 97" x 3'4" x 7'4"
LxWxH 5'6" x 2'3" x 7'4"
R&R Carpet
R&R Cazpet pad
R&R Carpet - metal transition strip
R&R Acoustic ceiling (popcorn) texture
Clean the walls - Heary
SeaVprime the walls - one coat (white pigmen[ed shellac)
Paint the walls - two coats
Mask the walls per square foot
R&R Smoke detector
4432 SF
44.32 SF
6.00 LF
4432 SF
198.00 SF
198.00 SF
198.00 SF
198.00 SF
1.00 EA
JCHACAESARSQUARE 07/05/2005 Page: 3
Disaster Solutions
7130 West 16th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
CONTINUED - Hallway
R&R Bifold door set - Birch veneer - Double
1.00 EA
Stain & finish bifold door set - slab only -(per side)
2.00 EA
R&R Interior door - lauan/mahogany - pre-hung unit-for both bedrooms
2.00 EA
R&R Door lockse[ - interior-both bedrooms
1.00 EA
Stain and finish door slab only (per side)
6.00 EA
1.00 EA
Clean light fixhue
28.00 LF
Clean shelving - wood
Seal & paint wood shelving 12"- 24" width
28.00 LF
Clean and deodorize building - Ozone treatrnent
150.00 CF
Room: Bathroom (full)
LxWxH 8'6" x 5'6" x 7'4"
.75 SF
46
Clean floor, strip & wac
1.00 EA
R&R Light baz - 3 lights
5.00 LF
Clean vaniry - inside and out
R&R Countertop - post formed plastic laminate
5.00 LF
252.08 SF
Clean the walls and ceiling - Heavy
Seal/prime the walls and ceiling - one coat (white pigmented sheliac)
252.08 SF
252.08 SF
Paint the walls and ceiling - rivo coats
20533 SF
Mask the walls per squaze foot
1.00 EA
Sink - single - Detach & reset
1.00 EA
Clean sink
3.00 EA
Clean sink faucet
2.00 EA
Clean outlet or switch
4.00 EA
Clean bath accessory
1.00 EA
Clean medicine cabinet - Large
R&R Interior door - lauan/mahogany - pre-hung unit
2.00 EA
1.00 EA
R&R Door lockset - interior
Stain and fnish door slab only (per side)
2.00 EA
1.00 EA
Clean toilet
JCHACAESARSQUARE 07/05/2005 Page: 4
Disaster Solutions
7130 West 16th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
CONTINUED - Bathroom (full)
R&R Toilet seat
1.00 EA
Clean baseboazd heater
5.00 LF
Paint baseboazd heater
5.00 LF
Clean ceramic tile
50.00 SF
Scrape and regrout tile
50.00 SF
Clean window unit (per side) 10 - 20 SF
1.00 EA
Clean door / window opening (per side)
1.00 EA
Clean shower door
2.00 EA
Shower door - slab only - Detach & reset
1.00 EA
Clean and deodorize building - Ozone treatment
150.00 CF
Room: Bedroom-1
Subroom 1: Closet
LxWxH 12'0" x 10'10" x 8'0"
LxWxH 8'6" x 2'3" z 7'4"
R&R 5/8" drywall - hung, taped, floated, ready for paint
Acoustic ceiling (popcom) texture
Texture drywall - machine
Seal then paint the walls and ceiling twice (3 coats)
Seal stud wall for odor control
Mask the walls per square foot
Rewire - Bid Item
R&R Interior door - lauan/mahogany - pre-hung unit
R&R Door lockset - interior
Stain and finish door slab only (per side)
R&R Light fixture - High grade
R&R Bifold door set - lauan/mahogany - Double
Stain & finish bifold door set - slab only -(per side)
Stain & finish door/window trim & jamb - Large (per side)
R&R Light fixture
JCHACAESARSQUARE
574.13 SF
149.13 SF
425.00 SF
574.13 SF
425.00 SF
425.00 SF
1.00 EA
1.00 EA
1.00 EA
2.00 EA
1.00 EA
1.00 EA
2.00 EA
2.00 EA
1.00 EA
07/05/2005 Page: 5
Disaster Solutions
7130 West 16th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
CONTINUED - Bedroom-1
R&R Aluminwn window, horiz. slider 12-23 sf (2 pane) 1.00 EA
R&R Baseboazd heat - steam or hot water 12.00 LF
R&R Closet shelf and rod package 8.50 LF
Paint - closet package (shelf, jamb & casing) 1.00 EA
R&R Carpet 149.13 SF
R&R Carpet pad 149.13 SF
R&R Smoke detector - High grade 1.00 EA
Clean and deodorize building - Ozone treahnent 150.00 CF
Waste Item - Carpet 51.06 SF
Waste Xpert - Cazpet Waste: The following cuts will produce the specified line item prices:
Cut 41 Room Name: Bedroom-1 Dimensions: 11'1" X 12'0"
Cut 42 Room Name: Closet & Closet Dimensions: 4'5" X 10'0"
Cut #3 Room Name: Hallway Dimensions: 4'11" X 7'2"
Room: Bedroom-2
Subroom 1: Cbset
General clean - up
Clean and deodorize building - Ozone treahnent
R&R Interior door - lauan/mahogany - pre-hung unit
R&R Door lockset - interior
Stain and finish door slab only (per side)
LxWxH 12'0" x 10'10" x 8'0"
LxWxH 8'6" x 2'3" x 7'4"
1.00 HR
150.00 CF
1.00 EA
1.00 EA
2.00 EA
JCHACAESARSQl1ARE 07/05/2005 Page: 6
Disaster
7130 West 16th Avenue
Lakewood, CO 80214
PH303-937-0717
FAX-303-922-6902
R&R Smoke detector - High gade 1.00 EA
Room: Hallway LxWxH 30'0" x 8'0" x 8'0"
Subroom 1: Offset LxWxH 9'0" x 3'0" x 8'0"
Clean and deodorize carpet - heavy staining 267.00 SF
R&R Stud wall - 2" x 4" - 16" oc 64.00 SF
R&R 5/8" drywall - hung & fire taped only 128.00 SF
Room: General
Dumpster load - Approx. 30 yards, 5-7 tons of debris 1.00 EA
Taaces, insurance, permits & fees (Bid item) 1.00 EA
Grand Total
`iFr3.4#2 47
Dennis Newell
JCHACAESARSQUARE 07/05/2005 Page: 7
~
a
w
=
5.2
~ y
V
Z >
W Q
~
~
a
~W)
Z
O
~N
~
W
~M
O
W
~N
No
oV)
~
F
V
L
4)
_
V
~
N
0
U
~
N
N
d
~
V
Q
~
O
~
L
R
0
%P
a
N
C
~
w
~
~
~
~
~
c
a
>
m
t
c
c
w
c
a
~
C
C
L M R