Loading...
HomeMy WebLinkAbout6650 W 47th AvenuePERMIT NO: JC -3 ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201705311 201705311 6650 W 47th AVE Residential Re -roof DECKING - 31 sq. ISSUED: 08/02/2017 EXPIRES: 08/02/2018 --e install Atlas Pinnacle asphalt shingles with ROOF *** CONTACTS *** OWNER (720)317-1269 BRUNING GARCIA LISA M SUB (720)643-5033 David Scheck 170158 Watershed Roofing & Restoratn *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT*: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,388.88 FEES Total Valuation 0.00 Use Tax 218.17 Permit Fee 220.15 ** TOTAL ** 4-38.32 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. 10/"34S'/ (0F Y�Nwl •o�� INSCORD upancv/Twe INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter uo Not Pour concrete Prior To Approval Of The Ahove Inman-tlnnc Underground/Slab Inspections Date Inspector Initials Comments Electrical Wall Sheathing Sewer Service Mid -Roof Plumbing uo Not Cover underground or Below/in-Slab Work Prior To Approval Of Tho Ohnva Incnad-finny Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof 3 Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather 0 A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: o Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Y se 3W When corrections have been made, call for re -inspection at 303-234- Date:- / 1=41 , � Inspecto�-_�' DO NOT REMOVE THIS NOTICE o City of Wheat Ridge Residential Roofing PERMIT - 201705311 PERMIT NO: 201705311 ISSUED: 08/02/2017 JOB ADDRESS: 6650 W 47th AVE EXPIRES: 08/02/2018 JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles with ROOF DECKING - 31 sq. *** CONTACTS *** OWNER (720)317-1269 BRUNING GARCIA LISA M SUB (720)643-5033 David Scheck 170158 Watershed Roofing & Restoratn *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,388.88 FEES Total Valuation 0.00 PAID Use Tax 218.17 Permit Fee 220.15` ** TOTAL ** 438.32 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201705311 PERMIT NO: 201705311 ISSUED: 08/02/2017 JOB ADDRESS: 6650 W 47th AVE EXPIRES: 08/02/2018 JOB DESCRIPTION: Residential Re—roof to install Atlas Pinnacle asphalt shingles with ROOF DECKING — 31 sq. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,�ppermrt. I rther attest that I am legally authorized to include all entities named within this document as parties to the work to be performed a that all work to be performed is disclosed in this docu ent and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTO (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official V.0 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dan Schultz L �� From: no-reply@ci.wheat ridge.co.us Sent: Monday, July 24, 2017 12:00 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Gina Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION 0J___ Property Address 6650 W 47th Ave Wheat Ridge 80033 Property Owner Name Lisa Brunning Property Owner Phone 720-317-1269 Number Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (for the City of Wheat Ridge) Contractor Phone Number Watershed Roofing and Restoration 170158 3034894198 Contractor Email Address maria@watershedroofs.com Retype Contractor Email maria@watershedroofs.com Address DESCRIPTION OF WORK Are you re -decking the Yes roof? Description of Roofing Atlas Pinnacle Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 31 material selected above? Does any portion of the No ✓ property include a flat roof? If yes, how many squares Field not completed. on the flat roof? TOTAL SQUARES 31 (pitched + flat) of all roofing material for this project z Provide additional detail tear off 1 layer, re deck, re roof 5/12 pitch here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract --T7,9- (0 -z, value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Maria Leyba Email not displaying correctly? View it in your browser. 3 Customer Payment Schedule Job #: 17-138 FtOO"FING Arl0 RESTORATION Carrier: State Farm Claim#: 06160701-17 Customer: Lisa Bruning Date of Loss: 5/8/2017 Address: 6650 W 4th Ave Wheat Ridge CO 80033 Project Manager: Dan Lephardt The following payment schedule is based on your carrier's approval of damages, taxes, coverage and deductible. The payment schedule may also reflect any cash payments you have chosen to have performed that are not qulaified under your claim's scope of damages. FINAL INSURANCE APPROVED FOR ALL DAMAGES: $ 21,711.60 Scope Performed by Watershed Roofing $21,105.09 Work Not Performed by Watershed Roofm; $ 606.51 Roof (house), gutters/downspouts (house), root (garage), gutters/downspouts (garage), paint (right elevation house), Water pressure valve, hardboard siding (right elevation stain (wood fence), paint (right elevation garage), windows garage) screens and units Initial Payment at Material Drop ACV $ 19,433.33 $ - Remaining Code Permit Fee as Final Payment when Work Completed payment Compliance incurred $1,671.76 $ - $ - Describe Cash Upgrade: $ 19,433.33 $ 1,671.76 Note that the estimate did NOT include the required plywood decking for the house and garage. This is required by code. This will be billed to State Farm as a supplemental item. Watershed will collect this amount when paid by State Farm. Estimated value of $5,339 (3,051 SF x $1.75 / SF) Cash Upgrade Cash Upgrade Cash Upgrade Paint Shingle Gutter System $ - $ - $ - $ - $0.00 Total Owed by Homeowner $21,105.09 TA :r Signature: D ate: Make Check Payable to: Watershed Roofing and Restoration 1360 S Wadsworth Blvd., Suite 116, Lakewood, CO 80232 Inspector Must Sign ALL Spaces pertinent to this project .- 7 Foundation Inspections I Ilia a .• Footing/Stemwall P.E. Letter Rough Inspections Date Inspector Comments Initials Wall Sheathing Roof Sheathing Lath / Wall Tie Rough Electric Rough P Rough Mech anical C&as Piping D o Not Proceed W ithout A roval Of Above Rough Framing TTY OF WHE RI t 1 48 AN c Insu lation - Drywall Screw t Pail Darcy Tokrak RECEIPT , NO-00008146 pSp R Tice �t� ANOUNT �T Final Inspections Gate Inspector I nitials ;�;� Final Elec trical Permit F ee Use Tax 40.88 Final Plumbing 1 Mechanical PAYMENT RECEIVED VS 2667 AMOUNT _Final Roof Auth Code: 56.7 #11995 F inal Building 1 Frame T T i. 56. 2 Rough Mechanical ----- ��---- ���.�------- -.�- -- � -- Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather K74 WSM NOZZI • 0 * . * Sub Contmctom: Exgl�tjonDate- Trade/Professlon: Ag royal: p_ VMI 19%x M W,?* 4 W- IN DEPARTMENT USE ONLY ZONfN0 COMMENTS Zoning: Reviewer PUGLIC WORKS COMMENTS: RevIewer BUILDING DePARTMONT COMMENTS: OCCUPANCY FIRE bZPARTMENY:: Q approved wl comments 0 disapproved 0 no review required M �UU7- INSPECTION RECORD Occnnancv /T INSPECTION REQUEST LINE: (303) 234 -5933 Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 3:00 p.m. to receive an inspection the following business day. Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Monolithic Slab Reinforcement Caissons Concrete Encased Ground (CEG) Footing /Stemwall P.E. Letter Do Not Pour Concrete Prior To Annroval Of The Above Insnections Underground /Slab Inspections Date Inspector Initials Comments Electrical (Underground) Sewer Service (Underground) Water Service (Underground) Plumbing (Below / In -slab) Date Inspector Initials Comments Heating (Below/ In -slab) Do Not Cover Underaround or Below /In -Slab Work Prior To Annroval Of The Above Insnections Rough Inspections Date Inspector Initials Comments Wall Sheathing Roof Sheathing Lath / Wall Tie Rough Electric Date Inspector Initials Comments Rough Plumbing Rough Mechanical Gas Piping Do Not Proceed Without Approval Of Above Rouah Inspections Rough Framing Insulation Drywall Screw / Nail Final Inspections Date Inspector Initials Comments Final Electrical Final Plumbing Final Mechanical Roof Final Building / Frame 4 CITY OF WHEAT RIDGE opt Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office - (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type <' Job Address ` A'� Permit Number ❑ No one available for inspection: Time A PM c Re- Inspection required: Yes No When corrections have been made, call for re- inspect' at 303 - 234 -5933 Date: Inspector: DO NOT REMOVE THIS NOTICE TICE ,PP,%1,09 So Ar VSv7S I AA ;F m TZ 15 ft ❑ No one available for inspection: Time AMAW Re-Inspection required: 4 �r No *when corrections have been made, call for re-inspection at 303-234 Date: '112 lnspector..', .mac DO NOT REMOVE THIS NOTICE * ** CONTACTS * ** owner 720/317 -1269 Lisa Bruning sub 303/945 -4457 Waltor McClendon 11 -0160 The Roof Doctor LLC ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: 0373 USE: UA BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 8,635.20 FEES' ' Permit Fee 188.45 Total Valuation .00 Use Tax 155.43�o ** TOTAL ** 343.88 . Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities amed within this document as parties to the work to be performed and that all work to be performed is disclosed in d cp j rent and /qX� XV accompanying approved plans and specifications. or CONTRACTOR (Circle one) Date 1. 2. 3. 4. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to afee equal to one- half of the original permit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed . or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Building Date T LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Residential Roofing PERMIT - 110851 PERMIT NO: 110851 ISSUED: 07/20/2011 JOB ADDRESS: 6650 W 47TH AVE EXPIRES: 07/19/2012 DESCRIPTION: Reroof 33.60 sqs of IKO 30 yr shingles * ** CONTACTS * ** owner 720/317 -1269 Lisa Bruning sub 303/945 -4457 Waltor McClendon 11 -0160 The Roof Doctor LLC ** PARCEL INFO ** ZONE CODE: UA SUBDIVISION: 0373 USE: UA BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 8,635.20 FEES' ' Permit Fee 188.45 Total Valuation .00 Use Tax 155.43�o ** TOTAL ** 343.88 . Conditions: 6 nails per shingle is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. Subject to field inspection. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities amed within this document as parties to the work to be performed and that all work to be performed is disclosed in d cp j rent and /qX� XV accompanying approved plans and specifications. or CONTRACTOR (Circle one) Date 1. 2. 3. 4. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to afee equal to one- half of the original permit fee. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed . or conceal work without written approval of such work from the Building and Inspection Services Division. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Building Date T LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. b City Of WheatR,�Oge COMMUNITY DEVELOPMENT Building 6 Inspection Services Division 7500 W. 29 Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 Inspection Line: 303 - 234 -5933 Date. 7 -Zp - )I Plan # Permit # 9,51 PiopertyAritlress} 6�,S0 Nt� , 17 k 1\\ie- Property Owner (please print) L, y ,,,P U1 n , a Phone: Mailing Address: (if different than property address) Address: City, State, Zip: CoMracto�: \ 11f_ �jmF �c�c,�n t �� C Contractors City License #: Electrical: City License # D"crioti6w work:? S(! e< s Building Permit Application Plumbing: e City License # i0 OQc.�C `o Cat 4 co et N� BTU's Gallons _ Amps Sq Ft. Mechanical: City License # Contra $ V alue• (�tIU Review Fee (due at time of submittal): s OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CLRCLEONE: (OWNER) (CONTRACTOR) or THORLZED REPRESENTA of (OWNER) (CONTRACTOR) PRINT NAM AIS l', Ml1e1A.0 CZZ SIGNATURE:, Bldg Valuation: N L 0 a w r W P 0 o d H V = i W'>p~ ~ ~ aU)o Z ~ ❑ O v c-Ln V!Lo L t U W ~ C N 00 O ~ N M O LL UI ❑ 1 ~ 19 F-I F' V N O LL. fl ❑ ~ u~i Q ` o a V ❑ U \oGE A ooa ~ N i o ; o I__I ~ ~lp V N N ~ ~ ~ Q ~ 0 ~ A C O U N ~ d CL ~ o Q 0 n ~ m a ~ E ~ N ~ 7 rC C i O N CL N I U C N ~ ~ o ~ N (O O V j U Q (Q tn N C ~ V O 'y O O K ro Z ❑ ❑ ❑ ~ ~ ~ w N ❑ City of Wheat Ridge Residential Electric PERMIT - 070611 PERMIT NO: 070611 . ISSIIED: 06/21/2007 JOB ADDRESS: 6650 W 47TH AVE EXPIRES: 12/18/2007 DESCRIP't20N: 200 amp aervice change . CONTACTS *•w . gc 303/296-7476 Michael Quigley 01-8644 Mercury Electric Co., Inc. owner 303/991-6204 Paul Tamburello ' PARCEL INFO . ZONE CODE: UA USE: UA SUBDIVISION: 0373 . BLOCK/LOT#: 0/ FEE`SUMMARY ESTIMATED PROJECT VALUATION: 2,300.00 - FEES I , PermitFee . 108.30 I Total Valuation .00 ' . . Use Tax 41.40 L;3 **.TOTAL 149.70 ' Com ments: . . Must meet 2005NEC . Subject to field inspection Ihereby certiEy that Che seCL dietancee propoeed by thie permit aPPlica[ion are accurate, and do not violate applicable ordinancea, rules or regulat a of the City of Wheat Ridge or wvenante, eaeemente or reetrictiona of rewrd; that all measuremenCe e5own,. all are accurate; that I have re and agree to abide by all coxtditione printed on thie applicatlon anQ t a spon bility for complia the Wheat Ridge euilding Code (I.s.C) and all other appllcahle wh for wor under i. Plan 'eubject [o field inepection. 07 Signare of ntrac r/o r . date . 1. Th1e pezmitwae eeue in ccordance ith the provieione eet forth in youx application and ie eubject to the lawe of the State of Colora o to he Zonin Regulatione and Building Codee of Wheat Ridge, Colorado or any other applicable ordinancee of t ~ ~ ity~. . 2. Thie pemit ehall enpire ys from the iseue date. Requeete fbr an extenaion muet be received prior to expiration flate. An.exteneion may be.granted at the diecretion oE Che Build;ing OfficiaL 3.if thie pexmit expiree, anew pemit may be acquired for a fee of'.one-half the amount normally required, provided no changgb have been or will be made in the original plane and epeci!fications and any auspeneion or abandonment hae not exceefled one (1) year. If cnangee have been or if euapeneion or abandonment exceede one (1) year, full feee ehall be paid for a new pexmit. 4. No vork of any maxvier ehall be done that will change the natural flow of water caueing a drainage problem. 5. Contr&ctor ehallnotify the Building Inepector twenty-fouz (24) hours in advance for all inepectiona and shall receive written apptoval on inapection card before proceeding with aucceseive phaeee of the job. 6. The ieeuance oE a pexmitor the approval of awinge and epecificstione ehall not be conatrued to be a pemit for, nor. an approval of,any violation of the pro ei ~of the building codee or any other ordinance; law, rule or regulation. All plan revieubjectto field in ect n Signatureof CJtW4*sftng 0~,/~~L / aate , - 4A4~_ IN3P8CTION REQII83T LINSe (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST B& MADE BY 3PM ANY BUSINESS DAY FOR'INSPECTION THE FOLLOWING BUSINSSS DAY. COMMUNITY DEVELOPMENT DEPARTMENT or pF WMEATP gUILDING INSPECTION LINE - 303•234-5933 ~i116~}5 _ 'o CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPLICA Property (7wner Property Address: Convactor License No.: O'NMERICCNTRACTOR SIGNATURE OF UNDERSTANOING AND AGREEMENT Building Permd Number: Dffie: Phone: ~ 3 ( ' 6 Lu ~ Phone: 3o3-Z46"~17~ Bulldfna Deot ValuaNon Figure: $ I hereby certiTy that the aetbaelc distances propoaed by Mie Pertnit applicatfon are accurale, and do nd vidate applk;able ordinences, rules w regulatbns of the City M Wheet Ridge or eovenaMs, easemerts a restrictions of reeord; that all measuremerrts shown, and allepatbns made are eccurate; Mat I have read end agree to ebWe by all condftions pAMed on Mis applkation and Mat I asaume tull responsiWlitY for comqle^ce o eo;e r~or wRO~~~,de~linia ~~i~~~) all fiother eW applicable Wh~l RMge (OYJNER)(GOf4TRAGTOR): _ . - L~ Use of Space (descripGon): Zo~ 441° ~V« pescription of work: Sq. Ft, added USE pnu~TnMeua~~n 64'50 W 4~ A~`~'ur bl $6qq Company: pnc'YLC,a2y L-vcT2ic COMMEMS: Approval: Zoning: CAMMENTS: Approval: WORK3 COMMENTS: Approval: DEPARTMENT COMMENiS: Approval: Value:$ Permit Fee:$ Plan Review Fee:$ se Tax:$ TOtsl:$ Efectrical License No: Piumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expiration Date: Ecpiration Date: Approval: Approval: _ Approval: _ (7 ) T his pertntt was issued in accordance `Nith the Provisions aet torth in your app~ic~ation and ia subJect to tha faws of the State ot r,oloredo and to the 2oning Reguletions and Buiidinp Codes of Whwt Ridpe, Cobrado a any dher applicabie ordinancee of ihe Cily. (2) Thfs permit shall expire if (A) lFie vrork authorized is not eommenced Wilhin saRy (90) days from issue dffie or (B) the build ng aNhorized ia suspendeA or abandoned fm a Period of 180 Aeys. (3) It this permit expires, a new Dermit meY be acquired trn e fee ot onahetl the artrouM rannaly reQuired. Providad rro ehangss have been or will be made in ihe original plans and specifroatbns and any suepensbn or abendonrtent has rwt exceeded °ne (1) Yew. If ohanges ryave been or if suepension w ebendonmeM exceads o^e (1) yenr, tull tees shall be peid ta a rxw permR. (4) No work of any manner ahall be cbne that will chanpe the nntural flow of water pusing e drainage problem. (5) CoMractor ahall rrotity the Building Inspectw lwantY-four (24) hours~ ~ tor ell Inspectiais end sMll receive wrKEen eppm+al ors inspedion card belore proceedirg with successrve phases o (g) 7he isstrence of a permit or the approval of drawings and specifications Shell not be construed to be a permft tor, noran apprwd of, any violation ot the prwisions of Me buildfng codes or any other wdinance, lew, rule or reguhation. All pian revfew is subject to fleld inspecllons.