HomeMy WebLinkAbout6650 W 47th AvenuePERMIT NO:
JC -3 ADDRESS:
JOB DESCRIPTION
City of Wheat Ridge
Residential Roofing PERMIT - 201705311
201705311
6650 W 47th AVE
Residential Re -roof
DECKING - 31 sq.
ISSUED: 08/02/2017
EXPIRES: 08/02/2018
--e install Atlas Pinnacle asphalt shingles with ROOF
*** CONTACTS ***
OWNER (720)317-1269 BRUNING GARCIA LISA M
SUB (720)643-5033 David Scheck 170158 Watershed Roofing & Restoratn
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT*: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,388.88
FEES
Total Valuation 0.00
Use Tax 218.17
Permit Fee 220.15
** TOTAL ** 4-38.32
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
10/"34S'/ (0F Y�Nwl •o��
INSCORD upancv/Twe
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site.
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date Inspector Comments
Initials
Pier
Concrete Encased Ground (CEG)
Foundation / P.E. Letter
uo Not Pour concrete Prior To Approval Of The Ahove Inman-tlnnc
Underground/Slab Inspections
Date Inspector
Initials
Comments
Electrical
Wall Sheathing
Sewer Service
Mid -Roof
Plumbing
uo Not Cover underground or Below/in-Slab Work Prior To Approval Of Tho Ohnva Incnad-finny
Rough Inspections
Date
Inspector
Initials
Comments
Wall Sheathing
Mid -Roof
3
Lath / Wall Tie
Rough Electric
Rough Plumbing/Gas Line
Rough Mechanical
Rough Framing
Rough Grading
Insulation
Drywall Screw/ Nail
Final Inspections Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage / Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof
Final Window/Doors
Final Building
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
0
A i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: o
Job Address:
Permit Number:
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Y se 3W
When corrections have been made, call for re -inspection at 303-234-
Date:- / 1=41 , � Inspecto�-_�'
DO NOT REMOVE THIS NOTICE
o City of Wheat Ridge
Residential Roofing PERMIT - 201705311
PERMIT NO: 201705311 ISSUED: 08/02/2017
JOB ADDRESS: 6650 W 47th AVE EXPIRES: 08/02/2018
JOB DESCRIPTION: Residential Re -roof to install Atlas Pinnacle asphalt shingles with ROOF
DECKING - 31 sq.
*** CONTACTS ***
OWNER (720)317-1269 BRUNING GARCIA LISA M
SUB (720)643-5033 David Scheck 170158 Watershed Roofing & Restoratn
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,388.88
FEES
Total Valuation 0.00 PAID Use Tax 218.17
Permit Fee 220.15`
** TOTAL ** 438.32
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
City of Wheat Ridge
Residential Roofing PERMIT - 201705311
PERMIT NO: 201705311 ISSUED: 08/02/2017
JOB ADDRESS: 6650 W 47th AVE EXPIRES: 08/02/2018
JOB DESCRIPTION: Residential Re—roof to install Atlas Pinnacle asphalt shingles with ROOF
DECKING — 31 sq.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this,�ppermrt. I rther attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed a that all work to be performed is disclosed in this docu ent and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTO (Circle one) Date
I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official V.0 Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dan Schultz L ��
From: no-reply@ci.wheat ridge.co.us
Sent: Monday, July 24, 2017 12:00 PM
To: CommDev Permits
Subject: Online Form Submittal: Residential Roofing Permit Application
Categories: Gina
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION 0J___ Property Address 6650 W 47th Ave Wheat Ridge 80033 Property Owner Name Lisa Brunning
Property Owner Phone 720-317-1269
Number
Property Owner Email Field not completed.
Address
Do you have a signed Yes
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
CONTRACTOR INFORMATION
Contractor Business
Name
Contractor's License
Number (for the City of
Wheat Ridge)
Contractor Phone
Number
Watershed Roofing and Restoration
170158
3034894198
Contractor Email Address maria@watershedroofs.com
Retype Contractor Email maria@watershedroofs.com
Address
DESCRIPTION OF WORK
Are you re -decking the Yes
roof?
Description of Roofing Atlas Pinnacle
Material
Select Type of Material: Asphalt
If "Other" is selected Field not completed.
above, describe here:
How many squares of the 31
material selected above?
Does any portion of the No ✓
property include a flat
roof?
If yes, how many squares Field not completed.
on the flat roof?
TOTAL SQUARES 31
(pitched + flat) of all
roofing material for this
project
z
Provide additional detail tear off 1 layer, re deck, re roof 5/12 pitch
here on the description of
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract --T7,9- (0 -z,
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Maria Leyba
Email not displaying correctly? View it in your browser.
3
Customer Payment Schedule
Job #: 17-138
FtOO"FING Arl0 RESTORATION
Carrier:
State Farm
Claim#:
06160701-17
Customer:
Lisa Bruning
Date of Loss:
5/8/2017
Address:
6650 W 4th Ave Wheat Ridge CO 80033
Project Manager:
Dan Lephardt
The following payment schedule is based on your carrier's approval of damages, taxes, coverage and deductible. The payment schedule may also reflect
any cash payments you have chosen to have performed that are not qulaified under your claim's scope of damages.
FINAL INSURANCE APPROVED FOR ALL DAMAGES: $ 21,711.60
Scope Performed by Watershed Roofing $21,105.09 Work Not Performed by Watershed Roofm; $ 606.51
Roof (house), gutters/downspouts (house), root (garage),
gutters/downspouts (garage), paint (right elevation house), Water pressure valve, hardboard siding (right elevation
stain (wood fence), paint (right elevation garage), windows garage)
screens and units
Initial Payment at Material Drop ACV
$ 19,433.33 $ -
Remaining Code Permit Fee as
Final Payment when Work Completed payment Compliance incurred
$1,671.76 $ - $ -
Describe Cash Upgrade:
$ 19,433.33
$ 1,671.76
Note that the estimate did NOT include the required plywood decking for the house and garage. This is required by code. This will be billed
to State Farm as a supplemental item. Watershed will collect this amount when paid by State Farm. Estimated value of $5,339 (3,051 SF x
$1.75 / SF)
Cash Upgrade Cash Upgrade
Cash Upgrade Paint Shingle Gutter System
$ - $ - $ - $ - $0.00
Total Owed by Homeowner $21,105.09
TA
:r Signature: D ate:
Make Check Payable to: Watershed Roofing and Restoration
1360 S Wadsworth Blvd., Suite 116, Lakewood, CO 80232
Inspector Must Sign ALL Spaces pertinent to this project
.- 7 Foundation Inspections
I Ilia
a .•
Footing/Stemwall P.E. Letter
Rough Inspections
Date
Inspector
Comments
Initials
Wall Sheathing
Roof Sheathing
Lath / Wall Tie
Rough Electric
Rough P
Rough Mech anical
C&as Piping
D o Not Proceed W ithout A roval Of
Above
Rough Framing
TTY OF WHE RI
t 1 48 AN c
Insu lation
- Drywall Screw t Pail
Darcy Tokrak
RECEIPT , NO-00008146
pSp R Tice �t�
ANOUNT
�T
Final Inspections
Gate
Inspector
I nitials
;�;�
Final Elec trical
Permit F ee
Use Tax
40.88
Final Plumbing
1
Mechanical
PAYMENT RECEIVED
VS 2667
AMOUNT
_Final
Roof
Auth Code:
56.7
#11995
F inal Building 1 Frame
T T i.
56. 2
Rough Mechanical
----- ��---- ���.�------- -.�- --
� --
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
K74
WSM
NOZZI
• 0 * . *
Sub Contmctom:
Exgl�tjonDate- Trade/Professlon: Ag royal:
p_
VMI
19%x
M W,?*
4 W-
IN
DEPARTMENT USE ONLY
ZONfN0 COMMENTS
Zoning:
Reviewer
PUGLIC WORKS COMMENTS:
RevIewer
BUILDING DePARTMONT COMMENTS: OCCUPANCY
FIRE bZPARTMENY:: Q approved wl comments 0 disapproved 0 no review required
M
�UU7-
INSPECTION RECORD Occnnancv /T
INSPECTION REQUEST LINE: (303) 234 -5933
Inspections will not be performed unless this card is posted on the project site.
Call the inspection request line before 3:00 p.m. to receive an inspection the following business day.
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date Inspector Comments
Initials
Monolithic Slab Reinforcement
Caissons
Concrete Encased Ground (CEG)
Footing /Stemwall P.E. Letter
Do Not Pour Concrete Prior To Annroval Of The Above Insnections
Underground /Slab Inspections
Date
Inspector
Initials
Comments
Electrical (Underground)
Sewer Service (Underground)
Water Service (Underground)
Plumbing (Below / In -slab)
Date
Inspector
Initials
Comments
Heating (Below/ In -slab)
Do Not Cover Underaround or Below /In -Slab Work Prior To Annroval Of The Above Insnections
Rough Inspections
Date
Inspector
Initials
Comments
Wall Sheathing
Roof Sheathing
Lath / Wall Tie
Rough Electric
Date
Inspector
Initials
Comments
Rough Plumbing
Rough Mechanical
Gas Piping
Do Not Proceed Without Approval Of Above Rouah Inspections
Rough Framing
Insulation
Drywall Screw / Nail
Final Inspections
Date
Inspector
Initials
Comments
Final Electrical
Final Plumbing
Final Mechanical
Roof
Final Building / Frame
4
CITY OF WHEAT RIDGE
opt Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office - (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type <'
Job Address ` A'�
Permit Number
❑ No one available for inspection: Time A PM
c Re- Inspection required: Yes No
When corrections have been made, call for re- inspect' at 303 - 234 -5933
Date: Inspector:
DO NOT REMOVE THIS NOTICE
TICE
,PP,%1,09 So Ar VSv7S
I AA ;F m
TZ
15
ft
❑ No one available for inspection: Time AMAW
Re-Inspection required: 4 �r No
*when corrections have been made, call for re-inspection at 303-234
Date: '112 lnspector..', .mac
DO NOT REMOVE THIS NOTICE
* ** CONTACTS * **
owner 720/317 -1269 Lisa Bruning
sub 303/945 -4457 Waltor McClendon 11 -0160 The Roof Doctor LLC
** PARCEL INFO **
ZONE CODE: UA
SUBDIVISION: 0373
USE: UA
BLOCK /LOT #: 0/
** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 8,635.20
FEES' '
Permit Fee 188.45
Total Valuation .00
Use Tax 155.43�o
** TOTAL ** 343.88 .
Conditions:
6 nails per shingle is required. Ice dam membrane is required from eave edge to
2' inside exterior walls. Board sheathing with any gap greater than 1/2"
requires panel sheathing overlay on entire roof. Sheathing inspection is
required prior to covering. Contractor shall provide ladder for inspections.
Scheduled inspections that cannot be performed due to inclement weather must be
cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee
will be assessed. Subject to field inspection.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and
specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the
legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform
the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all
entities amed within this document as parties to the work to be performed and that all work to be performed is disclosed in
d cp j rent and /qX� XV accompanying approved plans and specifications.
or CONTRACTOR (Circle one) Date
1.
2.
3.
4.
This permit was issued based on the information provided in the permit application and accompanying plans and
specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances,
regulations, policies and procedures.
This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must
be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted
at the discretion of the Chief Building Official and may be subject to afee equal to one- half of the original permit fee.
If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to
the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired
permits is at the sole discretion of the Chief Building Official and is not guaranteed.
No work of any manner shall be performed that shall results in a change of the natural flow of water without prior
and specific approval.
The permit holder shall notify the Building and Inspection Services Division in accordance with established policy
of all required inspections and shall not proceed . or conceal work without written approval of such work from the
Building and Inspection Services Division.
The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of
any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject
to field inspection.
Building
Date
T LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855
MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of Wheat Ridge
Residential
Roofing PERMIT
- 110851
PERMIT NO:
110851
ISSUED:
07/20/2011
JOB ADDRESS:
6650 W 47TH AVE
EXPIRES:
07/19/2012
DESCRIPTION:
Reroof 33.60 sqs of
IKO 30 yr shingles
* ** CONTACTS * **
owner 720/317 -1269 Lisa Bruning
sub 303/945 -4457 Waltor McClendon 11 -0160 The Roof Doctor LLC
** PARCEL INFO **
ZONE CODE: UA
SUBDIVISION: 0373
USE: UA
BLOCK /LOT #: 0/
** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 8,635.20
FEES' '
Permit Fee 188.45
Total Valuation .00
Use Tax 155.43�o
** TOTAL ** 343.88 .
Conditions:
6 nails per shingle is required. Ice dam membrane is required from eave edge to
2' inside exterior walls. Board sheathing with any gap greater than 1/2"
requires panel sheathing overlay on entire roof. Sheathing inspection is
required prior to covering. Contractor shall provide ladder for inspections.
Scheduled inspections that cannot be performed due to inclement weather must be
cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee
will be assessed. Subject to field inspection.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and
specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the
legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform
the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all
entities amed within this document as parties to the work to be performed and that all work to be performed is disclosed in
d cp j rent and /qX� XV accompanying approved plans and specifications.
or CONTRACTOR (Circle one) Date
1.
2.
3.
4.
This permit was issued based on the information provided in the permit application and accompanying plans and
specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances,
regulations, policies and procedures.
This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must
be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted
at the discretion of the Chief Building Official and may be subject to afee equal to one- half of the original permit fee.
If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to
the standard requirements, fees and procedures for approval of any new permit. Re- issuance or extension of expired
permits is at the sole discretion of the Chief Building Official and is not guaranteed.
No work of any manner shall be performed that shall results in a change of the natural flow of water without prior
and specific approval.
The permit holder shall notify the Building and Inspection Services Division in accordance with established policy
of all required inspections and shall not proceed . or conceal work without written approval of such work from the
Building and Inspection Services Division.
The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of
any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject
to field inspection.
Building
Date
T LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855
MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
b
City Of
WheatR,�Oge
COMMUNITY DEVELOPMENT
Building 6 Inspection Services Division
7500 W. 29 Ave., Wheat Ridge, CO 80033
Office: 303 - 235 -2855 * Fax: 303 - 237 -8929
Inspection Line: 303 - 234 -5933
Date. 7 -Zp - )I
Plan #
Permit # 9,51
PiopertyAritlress} 6�,S0 Nt� , 17 k 1\\ie-
Property Owner (please print) L, y ,,,P U1 n , a Phone:
Mailing Address: (if different than property address)
Address:
City, State, Zip:
CoMracto�: \ 11f_ �jmF �c�c,�n t �� C
Contractors City License #:
Electrical:
City License #
D"crioti6w work:?
S(! e< s
Building Permit Application
Plumbing:
e City License #
i0 OQc.�C
`o Cat 4 co et N�
BTU's Gallons _ Amps Sq Ft.
Mechanical:
City License #
Contra
$ V alue•
(�tIU
Review Fee (due at time of submittal):
s
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances,
rules or regulations of the City of wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on
this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work
and am also authorized by the legal owner of any entity included on this application to list that entity on this application.
CLRCLEONE: (OWNER) (CONTRACTOR) or THORLZED REPRESENTA of (OWNER) (CONTRACTOR)
PRINT NAM AIS l', Ml1e1A.0 CZZ SIGNATURE:,
Bldg Valuation:
N
L
0
a
w r
W
P
0 o d
H
V
=
i
W'>p~
~
~
aU)o
Z
~
❑
O v c-Ln
V!Lo
L
t
U
W ~ C N 00
O
~
N
M O
LL UI
❑
1
~
19
F-I
F' V N O
LL.
fl
❑
~ u~i Q
`
o
a
V
❑
U \oGE
A ooa
~
N
i
o
;
o
I__I
~
~lp
V
N
N
~
~
~
Q
~
0
~
A
C
O
U
N ~
d CL
~
o Q
0
n
~
m
a
~ E
~
N ~
7
rC C
i O
N
CL
N
I U
C
N ~
~
o ~
N (O
O V j
U Q (Q
tn N C
~ V O
'y O O
K ro Z
❑ ❑ ❑
~
~
~
w
N
❑
City of Wheat Ridge
Residential Electric PERMIT - 070611
PERMIT NO: 070611 . ISSIIED: 06/21/2007
JOB ADDRESS: 6650 W 47TH AVE EXPIRES: 12/18/2007
DESCRIP't20N: 200 amp aervice change .
CONTACTS *•w .
gc 303/296-7476 Michael Quigley 01-8644 Mercury Electric Co., Inc.
owner 303/991-6204 Paul Tamburello '
PARCEL INFO .
ZONE CODE: UA USE: UA
SUBDIVISION: 0373 . BLOCK/LOT#: 0/
FEE`SUMMARY ESTIMATED PROJECT VALUATION: 2,300.00
- FEES I ,
PermitFee . 108.30 I
Total Valuation .00 ' .
.
Use Tax 41.40 L;3
**.TOTAL 149.70 ' Com
ments: . .
Must meet 2005NEC .
Subject to field inspection
Ihereby certiEy that Che seCL dietancee propoeed by thie permit aPPlica[ion are accurate, and do not violate applicable
ordinancea, rules or regulat a of the City of Wheat Ridge or wvenante, eaeemente or reetrictiona of rewrd; that all
measuremenCe e5own,. all are accurate; that I have re and agree to abide by all coxtditione printed on thie
applicatlon anQ t a spon bility for complia the Wheat Ridge euilding Code (I.s.C) and all other
appllcahle wh for wor under i. Plan 'eubject [o field inepection.
07
Signare of ntrac r/o r . date .
1. Th1e pezmitwae eeue in ccordance ith the provieione eet forth in youx application and ie eubject to the lawe of the
State of Colora o to he Zonin Regulatione and Building Codee of Wheat Ridge, Colorado or any other applicable
ordinancee of t ~ ~ ity~. .
2. Thie pemit ehall enpire ys from the iseue date. Requeete fbr an extenaion muet be received prior to expiration
flate. An.exteneion may be.granted at the diecretion oE Che Build;ing OfficiaL 3.if thie pexmit expiree, anew pemit may be acquired for a fee of'.one-half the amount normally required, provided no
changgb have been or will be made in the original plane and epeci!fications and any auspeneion or abandonment hae not
exceefled one (1) year. If cnangee have been or if euapeneion or abandonment exceede one (1) year, full feee ehall
be paid for a new pexmit. 4. No vork of any maxvier ehall be done that will change the natural flow of water caueing a drainage problem.
5. Contr&ctor ehallnotify the Building Inepector twenty-fouz (24) hours in advance for all inepectiona and shall receive
written apptoval on inapection card before proceeding with aucceseive phaeee of the job.
6. The ieeuance oE a pexmitor the approval of awinge and epecificstione ehall not be conatrued to be a pemit for, nor.
an approval of,any violation of the pro ei ~of the building codee or any other ordinance; law, rule or regulation.
All plan revieubjectto field in ect n Signatureof CJtW4*sftng 0~,/~~L / aate , -
4A4~_
IN3P8CTION REQII83T LINSe (303)234-5933 BUILDING OFFICE: (303)235-2855
REQUESTS MUST B& MADE BY 3PM ANY BUSINESS DAY FOR'INSPECTION THE FOLLOWING BUSINSSS DAY.
COMMUNITY DEVELOPMENT DEPARTMENT
or pF WMEATP gUILDING INSPECTION LINE - 303•234-5933
~i116~}5 _ 'o CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80033 - (303-235-2855)
APPLICA
Property (7wner
Property Address:
Convactor License No.:
O'NMERICCNTRACTOR SIGNATURE OF UNDERSTANOING AND AGREEMENT
Building Permd Number:
Dffie:
Phone: ~ 3 ( ' 6 Lu ~
Phone: 3o3-Z46"~17~
Bulldfna Deot ValuaNon Figure: $ I hereby certiTy that the aetbaelc distances propoaed by Mie Pertnit applicatfon are
accurale, and do nd vidate applk;able ordinences, rules w regulatbns of the City M
Wheet Ridge or eovenaMs, easemerts a restrictions of reeord; that all measuremerrts
shown, and allepatbns made are eccurate; Mat I have read end agree to ebWe by all
condftions pAMed on Mis applkation and Mat I asaume tull responsiWlitY for comqle^ce
o eo;e r~or wRO~~~,de~linia ~~i~~~) all fiother eW applicable Wh~l RMge
(OYJNER)(GOf4TRAGTOR):
_ . - L~
Use of Space (descripGon): Zo~ 441° ~V«
pescription of work:
Sq. Ft, added
USE
pnu~TnMeua~~n
64'50 W 4~ A~`~'ur
bl $6qq
Company: pnc'YLC,a2y L-vcT2ic
COMMEMS:
Approval:
Zoning:
CAMMENTS:
Approval:
WORK3 COMMENTS:
Approval:
DEPARTMENT COMMENiS:
Approval:
Value:$
Permit Fee:$
Plan Review Fee:$
se Tax:$
TOtsl:$
Efectrical License No: Piumbing License No: Mechanical License No:
Company: Company:
Company:
Expiration Date: Expiration Date: Ecpiration Date:
Approval: Approval: _ Approval: _
(7 ) T his pertntt was issued in accordance `Nith the Provisions aet torth in your app~ic~ation and ia subJect to tha faws of the State ot
r,oloredo and to the 2oning Reguletions and Buiidinp Codes of Whwt Ridpe, Cobrado a any dher applicabie ordinancee of ihe
Cily.
(2) Thfs permit shall expire if (A) lFie vrork authorized is not eommenced Wilhin saRy (90) days from issue dffie or (B) the build ng
aNhorized ia suspendeA or abandoned fm a Period of 180 Aeys.
(3) It this permit expires, a new Dermit meY be acquired trn e fee ot onahetl the artrouM rannaly reQuired. Providad rro ehangss have
been or will be made in ihe original plans and specifroatbns and any suepensbn or abendonrtent has rwt exceeded °ne (1) Yew. If
ohanges ryave been or if suepension w ebendonmeM exceads o^e (1) yenr, tull tees shall be peid ta a rxw permR.
(4) No work of any manner ahall be cbne that will chanpe the nntural flow of water pusing e drainage problem.
(5) CoMractor ahall rrotity the Building Inspectw lwantY-four (24) hours~ ~ tor ell Inspectiais end sMll receive wrKEen eppm+al
ors inspedion card belore proceedirg with successrve phases o
(g) 7he isstrence of a permit or the approval of drawings and specifications Shell not be construed to be a permft tor, noran apprwd of,
any violation ot the prwisions of Me buildfng codes or any other wdinance, lew, rule or reguhation. All pian revfew is subject to
fleld inspecllons.