HomeMy WebLinkAbout7879 W 46th Avenue0
i CITY OF WHEAT RIDGE
Building -Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: 14017- a ! P o o-4
Job Address: -7 G -7 1"l W Ll L �b A �e
Permit Number: -�) C /S o a r 41 o
❑ No one available for inspection: Time = 3 _-_? A M
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date: ,�-6 / 7 b '3 Inspector: T b
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
Residential Roofing PERMIT - 201802140
PERMIT NO: 201802140 ISSUED: 07/31/2018
JOB ADDRESS: 7879 W 46th Ave EXPIRES: 07/31/2019
JOB DESCRIPTION: Reroof remove and install Dimensional Malarkey Legacy Asphalt Shingles with
24 squares. Pitch 4/12.
**Revision Add Redecking 16 squares only required****
*** CONTACTS ***
OWNER (303)278-1988 BAILLIE BRIAN H
SUB (303)501-0605 Daniel Sarabia 170502 Golden Roofing, Inc
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,620.00
FEES
Total Valuation 0.00
Use Tax 286.02
Permit Fee 267.70
** TOTAL ** 553.72
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201802140
PERMIT NO: 201802140 ISSUED: 07/31/2018
JOB ADDRESS: 7879 W 46th Ave EXPIRES: 07/31/2019
JOB DESCRIPTION: Reroof remove and install Dimensional Malarkey Legacy Asphalt Shingles with
24 squares. Pitch 4/12.
"Revision Add Redecking 16 squares only required""
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this ermit. I fu a hat I am le ally authorized to include alI entities named within this document as parties to the work to be
performed and hat all work o be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of r0JffJ& or CONTRACTOR (Circle one) Date
I. This perms was issued based on the information provided in thepermit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or grantinga permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicabjpxzoode or any or r ince or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
`1 `I heat �idge
COMMUNITY DEVELOPMENT
Building & Inspection Services Division
7500 W. 291h Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: permits(a)ci.wheatridge.co.us
FOR OFFICE USE ONLY
Date: (71, � I
Add to Permit #
Building Permit Revision/Amendment Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address:
Property Owner (please print): r/a4 Phone: g. Z 2�.Zkkg
Property Owner Email:
Mailing Address: (if different than property address)
Address:
City, State, Zip:
Contact Person: I: Cis d )-rl) �C412_) c{ Phone: D O I U �� D
Contractor:
4 -
Contractors City License #:�_�_ Phone: 3 0 2 1:7 O f D �., 0 S
Contractor E-mail Address: ,
Please Note: Additional valuation must include all general and subcontracted work to be performed
related to the revisions and/or amendments declared in the description of work and which were not
included in the original permit valuation.
If revisions or amendments increase the original valuation, additional fees will be due at the time of
approval. Depending on the scope of work, additional plan review fees may be due upon approval
($60.00 an hour — 2 hour minimum).
Description of revised/amended work:
b -sy w r�s
Sq. FL/LF
Amps
a n ly
Btu's
Gallons
Squares Other
Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above)
$ 1-52-o a'
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application.
CIRCLE ONE: (OWNER)( -(CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
PRINT NAME: /us l[tr_h___2 a xa L SIGNATURE:
ZONING COMMMENTS:
Reviewer.
BUILDING DEPARTMENT COMMENTS:
Reviewer:
PUBLIC WORKS COMMENTS:
Reviewer:
PROOF OF SUBMISSION FORMS
Fire Department ❑ Received ❑ Not Required
Water District ❑ Received ❑ Not Required
Sanitation District ❑ Received ❑ Not Required
DEPARTMENT USE ONLY
DATE:
OCCUPANCY CLASSIFICATION:
Building Division Valuation: $
c4
xa i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office - (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: L1 Oct - t , n c; (
Job Address: -7153 -7 f ' w `-J �, = h v�
Permit Number: -;) p j S 9 ) y am
c
P)e(5�Ge f`CSC t,J in i`-, L/
❑ No one available for inspection: Time % (QPM
Re -Inspection required: 6s No
When corrections have been made, call for re -inspection at 303 -234 -
Date: $/ / 1g Inspector: --T- fl
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
_��9�Building Ir pection'0�vision
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSP0:3 IONS . <2F� n9
Inspection Type: 304, - 131
Job Address: -7 S '7 9 L✓ �-� '�
Permit Number: Go 0 J Z-) D
he
❑ No one available for inspection: Time 11= 3 1 tQPM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date: is /'9 //g Inspector: _TL
DO NOT REMOVE THIS NOTICE
A 41 City of Wheat Ridge
�. V-
'� Residential Roofing PERMIT - 201802140
PERMIT NO: 201802140 ISSUED: 07/31/2018
JOB ADDRESS: 7879 W 46th Ave EXPIRES: 07/31/2019
JOB DESCRIPTION: Reroof remove and install Dimensional Malarkey Legacy Asphalt Shingles with
24 squares. Pitch 4/12.
*** CONTACTS ***
OWNER (303)278-1988 BAILLIE BRIAN H
SUB (303)501-0605 Daniel Sarabia 170502 Golden Roofing, Inc
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,100.00
FEES
Total Valuation 0.00
Use Tax 254.10
Permit Fee 251.85
** TOTAL ** 505.95
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle.. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201802140
PERMIT NO: 201802140 ISSUED: 07/31/2018
JOB ADDRESS: 7879 W 46th Ave EXPIRES: 07/31/2019
JOB DESCRIPTION: Reroof remove and install Dimensional Malarkey Legacy Asphalt Shingles with
24 squares. Pitch 4/12.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I , the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performe
d
and work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
`3
cr
l.�l' ,Iy//,-2/ .7 yi rc/
Signature off= VWNER or CONTRACTOR (Circle one) Date
I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original ermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issuance r granting of rmit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable o or ny ordi ce or regulation of this jurisdiction. Approval of work is subject to f any
inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
La enia Reimer
From: no-reply@ci.wheatridge.co.us
Sent: Tuesday, July 31, 2018 12:44 PM
To: CommDev Permits
Subject: Online Form Submittal:. Residential Roofing Permit Application
Categories: Gina
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. The Building Division permit counter is open from
7:30 am to 3:30 pm, Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home �p
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
7879 W 46av Wheat Ridge, CO
Brain Kelley
Property Owner Phone 303-278-1988
Number (enter WITH
dashes, eg 303-123-4567) �—�
both? (check all that
apply)
What is the specific pitch ! 4:12
of the PITCHED roof?
How many squares are
part of the PITCHED
roof?
Describe the roofing
materials for the
PITCHED roof.
Type of material for the
PITCHED roof:
Provide any additional
detail here on the
description of work. (Is
this for a house or
garage? Etc)
24
Dimensional Asphalt shingles, malaky
i
Asphalt <%
tear off to the deck
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
3
~
m
-
zr
a
c
d o
-i
~ e
~
3a
0
a
o
C1
CL o
~
m
d~
=
oV
(D
0
(D
~o
.
W h
<
!
$ .i ~
m
m.>
p
~
_
«
~
Q
~
o (D
o
3
aq
a
^
~a
~
,
~
to
~ a
~
o?
~
*~CW
<
o
N
*rn
~
D
0
m
ri
~
o
m
3
~
~
Z
co 3
"I
o+
~ A
N w
a
~
` DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number 13780
BUILDING INSPECTION LINE - 303-234-5933
Date 4/30/02
:
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Property Owner: DALE DAVIS
Property Address: 7879 W 46TH AVE
Phone: 940-7760
Contractor License No. :
Company :
Phone :
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value : $1,800.00
I hereby certify that the setback distances proposed by this permit application are accurate, and
Permit Fee : $63.15
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
Plan Review Fee : $41
05
covenants, easements or restrictions of record; that all measurements shown, and allegations
.
made are accurate; that I have read and agree to abide by all conditions printed on this
US2 T8X : $36.00
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
.
.
Code (U.B.C.) and all other applicable W~ t idge ordi A~,-for work under this permit.
_
.
_ _
_
TOtal : $14020
(OWNER)(CONTRACTOR) SIGNED ATE S'O
Use:
Description : DECK WITH TWO STORY CROWS NEST
Please Note:
for locatiI property
I `'m••••,•••... : _ - . . __.........,,.r~ srrnrd:n2 to tn'J
Approval : MLC
Zoning : R-2
Approval: BG
BUILDWG DEPARTMENT USE
d
covok~n ~e~~`~ecuate irf rm.
app d lot an aud cesponsibreyuireL~#~~F~? .
The Cit
COMPLIES W/ R-2 REGS. su?~mitted ~vithin :he 4ilan st und any ccasl«.ot,
~rors resultl;,g Crot~~ inacr~;~'.~ lr.:`orr.4:::iun.
4/30/02. ACCESS TO CROWS NEXT WILL BE FIELD VERIFIED.
Approval :
Occupancy : Walls
Roof : Stories : Residential Units :
Electrical License No :
Company :
Plumbing License No :
Company :
Mechanical License No :
Company
Expiration Date :
Approval:
Expiration Date :
Approval :
Expiration Date :
Approval :
(1) 7his permit was issuetl in accordance with the provisions set forth in yopur application and is subjeci to ihe laws of ihe State ot Colorade and ro me Zoninq
Regulations and Building Code of Wheat Ridge, Coloratlo or any other applicable ortlinances ot Ihe City.
(2) This permit shall expire if (A) the work authorizetl is not commencetl within sixry (60) tlays from issue date or (6) the builtling authorized is suspended or
abandoned for a penod of 120 days.
(3) If this permit expires, a new pertnit may be acquired for a fee of one-half lhe amount normally required, provided no changes have been or will be made in the
original plans and specifications antl any suspension or abantlonment has not exceetletl one (1) year. If changes are made or if suspension or abantlonment
exceeds one (1) year, full fees shali be paitl For a new permit.
(4) No work of any manner shall be tlone that will change the natural flow of water causing a dreinage problem.
(5) Conlractor shall notify the Building Inspector hventy-four (24) hours in advance for all inspections and shall receive written approval on inspection cartl before
proceediing with successive phases of the job.
(6) The issu f a p~ermiyt (ihe approval of drawings antl specifcations shali not be construed to be a permit For, nor an appmval of, any violation of the
pro' ' s o h~~~fyqyy~odes or any other ordinance, law, rule or re9ulation.
L
Chief Building In 6ector
oF wHE4T DEPARTMENT OF PLANNING AND DEVELOPMENT
n BUILDING INSPECTION LINE - 303-234-5933
~ ° CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
~O~oRAO~ WHEATRIDGE,C080215-(303-235-2855)
. t~-d
Property Owner:
.-Bvitding PermiTdJumber:
' Date:
\
"
ii
A~f i i r.' . _
~ _1
PropertyAddress: 7 SS ? 9 c~y~' t 4
Contractor License No.:
, Company: 4-C/ /1 f r-
Phone :3G i,."-'945';10?74'C
,f /S
OWNER/CONTRACTORSIGNA7UREOFIINDERSTANDINGANDACREEMENT
I hereby cerfify thatthe se[back distances proposed by this pemit application are awurate,
md do no[violate applicable ordinances, rules or regulations of Ihe City of Whea[ Ridge or
wvenants, easements or restric[ions ofrecord; that alf ineasurements showq and allegations
made are accurate; that I have read and agree to a6ide by aIl condi[ions printed on [his
epplication and that I assume fiill responsibility for wmpliance witlh tlie Whcat Ridgc
Building Code (U.B.C) and all other applicable Wheat Ridge Ordinances, for work under
this permit.
(OWNER)(CONTRACTOR):SIGNED DATE t"bQ
Consnuction Value:$ ( $~Jo , ~
Permit Fee:$
P1an Review Fee:$
Use lax:$
TOt31:$
' Description: 016e le, i °i `f Gt~CS, .°iioVy ~4'G3~S i'L[o s "7L
ZONING COMMENTS:
Approval: ~ e-
ZOR1Ilg:
BUILDING COMMENTS:
Approval: 14 C
PUBLIC WORKS COMMENTS:
Approval:
Occupancy:
BUILDING DEPARTMENT USE ONLY
.~~+~.i~o2 A~~tss fo e'ro s r,
w: Le ~:s/~ves
Walls: Roof: Stories:
t! / S
.~..7
J ~----.i `
Residential Units:
Elechical License No: Plumbing License No: Mechanical License No:
Company: Company: ComPan
Y
Expfration Date: Expiration Date: Expiration Date:
Approval: Approval: Approval:
(1) This pemit was issued in accordance witli the provisions set forth in your applicatiou and is subject ro the laws of Nie State of Colorxdo and m Hie Zoning
Regidatlovs end Building Codes of Wheat Ridgq Colorado or any othu applicable ordinances af tlm City.
(2) This pemit shall expire if (A) the work aatlmnzed is not commenred wi[liin sixty (60) days Gom issue dzte or (B) tlie building au[horized is suspenAed or
abandoned for a period of 120 days.
(3) if Chis pemit exp'ves, a vew permit may be acquired for a fee of one-half the amount nortnally requireA, proviAed no chan¢es have been ar will be made in
Ne original plans and specificafions and any snspevsion or zbandonment hu not exceeded one (I ) year. ifchanees have been or if suspension nr ahanAnnmenr
exceeds one (1) yeaz, full fees shall be paid for a new permit.
(4) No work of any maouer shall be done tlhat will change the nahval flow of water causing a drainage pro6lem.
(5) ConhactorshallvotlfytheBuildinglvspectorlwe¢Ty-Fonr(24)hoursinadvanreforallinspectionsandshallreceivewrittenapprovzloninspectioncm'dbefore
proceediag witli successive phases of tUe job.
(6) 17ie issaance of a pemit or t6e appioval of drawings and specificatlons shall noc be consmied ro be a pennit foq nor an apprwal of, any violation of the
provisions of the uilding codes or any other ardinavice, law, mIe or regulafion.
Chief Building Insp tor
Da ~30 ~o oMpIRodEMENT LOCaTuoH c ERTFoCQTE
LOT 15 LEGAL DESCRIPTION:
LOT 2, BLOCK 2,
8O~ HILLCREST HEIGHTS,
COUNTY OF JEFFERSON,
3' UTILTIY AND DRAINAGE EASEMENT 8530 P93 STATE OF COLORADO.
I ~
I ~
WI LOT 2 W
~i i~ LOT 3
~I I~
Z' I Z
a~ ~a
ol o
0 0
}I CRAWL I}
~ F- SPACE ~
.
~ r , DOOR `
F-
O ] j CONC. PATIO
~
I 55.2' I
I i, 1 STORY i- I
O FRAME & STUCCO O
I N #7II79 N I
1 Ei.S' 6.3'
22.1 ' 14. 5'
I ZD '0 I
~ 06 16.6' °0 ~
~ DECK
I 0 20
I I ~
I I I I ~
w
' iW i 03 o I Scale: 1" = 20'
I d I
I Z I
I ~ 0 ~ I
I I U I I FOUND 4" WATER
PIPE IN CONC.
I I
FOUND #5 REBAR ~
W/ ALLOY CAP $Q
WEST 46TH AVENUE 50' R.O.W.
THE LOCATION OF THE IMPROVEMENTS SHOWN WERE DETERMINED UTILIZING FENCES AND ROADWAYS.
FENCES AND/OR OTHER LINES OF OCCUPATION ARE NOT SHOWN, UNLESS OTHERWISE INDICATED.
THE LEGAL DESCRIPTION WAS PROVIDED BY DALE DAVIS. THERE ARE NO EASEMENTS ON THIS
PROPERTY ACCORDING TO THE RECORDED PLAT. NO TITLE COMMITMENT WAS PROVIDED.
I HEREBY STATE THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED FOR DALE DAVIS THAT IT IS NOT
A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR
ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT LINES. I FURTHER STATE THAT THE
IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE 4-26-02, EXCEPT UTILI71' CONNECTIONS, ARE
ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS
UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND
THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID
PARCEL, EXCEPT AS NOTED. JcA
FOR AND ON BEHALF OF D.R.A,*SIfRV~IN G, INC. NOIICE: AmNing b Cobrvtla ww you uusr comm~ any ipai acuon nm.a on wy aefect in w. i.Lc.
2484 KIPLING STREET t~CEWOOQ~COC.DfiApO rRNn Nm yaan afGr you tirt Olamver wN Aefact In na went may wy actbn bmM upon arty Mect
in W. I.LC. W comm~nwtl mon Man len yean /~om Lw uk Eak ot Na caNflmWn Nown Mnon.
~ CLIENT: DALE DAVIS
s i~ADDRESS: 7f379 WEST 46TH AVENUE
crzecoav ~,wes Ke~ryq DATE: 4-26-02 DRA N0. 85069
COLORADQ PROFESSIOt~pL 14RVET6f2'Np' 16461
Directlons
Fill in the blanks on pages 2 and 3 with dimensions
and materials which will be used to build the
structure. Please printlegibly.
2. Indicate in the check box which detail from page 3 will be used.
lx or
1 x
decking
Existing bldg. 36 inch high guardrail with
-
pickets or intermediate rails
~
spaced so that a 4 inch diameter
sphere cannot pass through
c
E
Nail decking to joists with
/
w
d
~
galvanized deck nails or screw
~
,
to joists with non-corrosive
B
etail ~e PaBe A
U3 Detall B
❑ Alternate Detail B7
❑ Alternate Detail B2
(see pege 3)
a
d
~
~
c
~
LL
~
Detail C
(see pege s)
Finished
Note: If an exit or egress from the existing
~
building passes under the proposed deck, or if
there is an existing patio under the proposed
~
d
deck, a minimum clear headroom of not less
~
than 6ft. 8in. must be maintained under the
~
beam. Please indicate openings in existing walL
~
71?7q
Cd O S'SOO~ j
t"
J
2x_':9' joists
spaced 1f apart
*empe:2x 10•sPecea24-eaa.q
('z1 Z x -9L-beam
/exemple: (2)2x ro - see deran e/
2x_ rim joist
(ezempe: z x to- see attemffie et s e2)
xgr ' posts
spaced /W_ apart
(ezamp/e: 4 x 4 posts spacetl B'apart)
Span (o -.0"
(aremple: 13'-4')
Note: A floor plan (plan view) showing the dimensions of your project or additions and its relationships to existing buildings or
structures on the property must be included. In addition to project dimensions, your floor plan must also show other details such
as post locations and spacing, joist and beam spans, and any other pertinent information not shown on the section drawing.
This handout was developed by the Colorado Chapter of the InternaUonal
Conference of Building Officials as a basic plan submittal under the
1994 Uniform Codes. It is not intended to cover all circumstances.
Check with your Building Department for additional requirements.
~
n
S
T
~
)
~J
~
1 ;
1
~I
n
~ i
~
I
~
_
~ I
~
I I
~
I ~
~
~
-o '
ti
I ~
(o
I `Cl
C_
ti
~ ~ pt
7 ry
ro
~
-
~
_
-
~
G`
ss '
1
.,`'FNOV`t"La
...Gl 3~10 z
-
L
~
-
~K
i
3
\
~
-
-
- -
IrJ
TJ
(
~
vn
1
/
~
► ,
N ~
~
a
~
~
~
-i-
n
ro
~
~
~r
\V
~y}
~
c
~
~
`Z;
~
n
~
~
r~
~
~
7
~
~
~
~
C
:::Z
~
~
~
~
~i-
l
rU
~ U
S GJ
_
G
~
1
fc ~
~
~
~
ti
C'
-b
O
~
<
~
\
-
4 ~
\ri ~
a
iE_
N ~
I
~ ~
~
~
~
,n.
~
~J J
~
1
o~
4
~
~
~
t~
i
~
~
~
~
~
[s F`~
~ ~ rJ
w
C',fi-
6-
I I I
v~~iT -F •S ~ 7 ~ K N
y
%o
L~
7
~
~4-
0
~
o'
c~
~
DEPAF`TMENT OF PLANNING AND DEVELOPMENT
BUIcDING INSPECTION LINE - 303-234-5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303-235-2855)
Building Permit Number
Date
12723
8/31 /01
Property Owner :
Property Address : 7879 W. 46TH aVE
Contractor License No. :
Phone: 303-940-7760
Company : Phone :
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, a
do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restridions of record; that all measurements shown, antl allegation
made are acwrate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (II.B.C.) and all other applicable Wheat Ridge r~ ances, for work under this permit.
(OWNER)(CONTRACTOR) SIGNED DATEJA/J~
Construction Value : $$00.00
nd
Permit Fee : $32.65
Plan Review Fee : $0.00
Use Tax : $20.00
s
Total: $52.65
Use:
Description : SERVICE IN KITCHEN. NEW SERVICE PANEL AND METER.
BUILDING DEPARTMENT USE ONLY
SA- W~ SIC : Sq. Ft. :
Approval :
Zoning :
IM .~o°,,'ng
Approval :
Approval:
Occupancy : Walls : Roof : Stories : Residential Units :
Electrical License No :
Company:
Expiration Date :
Approval :
Plumbing License No :
Company:
Expiration Date :
Approval :
Mechanical License No :
Company:
Expiration Date :
Approval :
(1) This permit was issuetl in accortlance with the provisions set forth in yopur application antl is sub1ecl to ihe laws of the State of Colorado antl to lhe Zoning
Regulations and Building Code ot VJheat Ridge, Coioratlo or any other applicable ordinances of the City.
(2) This permit shall expire if (A) the work authorized is not commenced within siMy (60) days trom issue date or (B) the builtling authonzed is suspended or
abantlonetl for a periotl of 120 days.
(3) If this permit expires, a new permR may be acquired for a fee of one-half the amount normalry required provitled no changes have been or will be matle in the
original plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are matle or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new pertnit.
(4) No work of any manner shall be tlone that will change the natural Flow of water causing a drainage problem.
(5) Coniractor shall notify the Building Inspector lwenty-four (24) hours in advance For ail inspec6ons antl shall receive written approval on inspection card bePore
proceediing wi[h succ e phases ot the1'ob.
(6) The issuance of. it r the I ot drawings and specifcalions shall not be construed to be a permit For, nor an approval of, any violation oFthe provisions
ot the builtling co or y ance, law, rule or regula6on.
~
Chief Building Inspector
oF WHE.qr DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number:
{ 1.po BUII.DING INSPECTION LINE - 303-234-5933 Date:
~ m GTTY OF WHEAT RIDGE
7500 WEST 29TH AVE1ViJE
WHEAT RIDGE, CO 80215 - (303-235-2855)
cOCORAO~
4jl ,y-Pi"H~.1pp CATdpO7~~
~l
Froperty Owner: ~
Properry Address: G (
Contractor License No.: ~ ~ Phone
:-7;'o~' ~ yO 77,~ U
Company: {,o14 Phone:
OWNER/CONTRACPOR SIGNATURE OF
AGREEIIEKNT
Construction Value:
I hereby ceRify that the setback distances proposed by tlils pamii applicatioa aze
accurate, md do not violate applicable ordinances, niles or regulafions of the City of
WheazRidge or covenantr, easemen4 or restrictioas ofrecocd; that aIl meesurements
shown, aad allcgatioas made are accurate; thaz I have road md agree tn abide by afl
conditions printed o¢ this application md flut I assume fiill responsibility-for
compliaaci; with thc Wheat Ridge Buiiding Codc (UB.G) aad all other applicable
Wheat Ridge Ordinancos, for work undcr ttus petmit ~ . .
(OF'NER)((ANIRACT0R):
Permit Fee:
Plan Review Fee:
Use Tax:
TOt31:
Description: 5 e f✓,fC~ , G 4 P
~'1 Osi .7/et'IJ nat) I~'LETf{/`
BUII.DING DEPARTMENT USE ONLY
SIC: Sq.Ft.:
ZONING COMMENTS: -
Approval:
Zoning:
BUILOING COMMENTS:
Approval:
PUBLIC WORKS COMMENTS:
Approval:
Occupancy: Walls: Roof. Stories: Residenrial Units:
Electrical License No: Plumbing License No: Mechanical License No:
Company: Company: Company:
Expiration Date: Expiration Date: Expiration Date:
Approval: Approval: Approval:
(1) Tltis petmit was issued in accordance witL the provisioas set foefh i¢ your applicaROn and is subject to the laws of the State of Colondo md to the Zoning
Regulations a¢d Building Codes of Wheat Ridgq Colocado ar any other applicaWe ord'wances of tlw City.
(2) This pecmit shall ezpire if (A) the work authoriud is not commwced within sixty (60) days from issue daie or (B) the building authorized is suspmded or
abandoued for a pcriod of 120 days. ,
(3) if this pecmit arpires, a new pecmit may be acquired fox a fr< of one-half tlie amount no:melly mquiced, provided no changes have bee¢ or Will be made in
the original plans md specifications md a¢y suspensio¢ar abandoumenthu ¢oc ezceededone (1) yeat. Ifchanges have been oxifsutpeasion orabandonment
ezeeeds o¢e (1) year, full fres shaLL be paid fot a new peimit
(A) No work of any memer shall be do¢e that witl change the natueal flow ofwata causi¢g a drainage problem.
(5) Contracror shallnoRfyt6eBuildingSaspectorhvmty-FOw(24)howsinadvaneefwallinspectonsandshall aceivewritte¢approvalonmspec¢oncardbefwe
proceedi¢g with succesaive phases of the job. (6) Tne issnance of a pecmit or the approval of dvawings md specificafions shall not be construed to be a pecmit for, ¢or an approval of, any violation of the
proviuous of tLe build'mg eodes or aay other ocdinance, law, nile or reguLation.
Chief Building Inspector
DEP,A 7WENT t)IF PI,ANN1NQ AI!D DEYEI.OPMfNT Building Permit Number : 95-2076
CiW tNSPECTIGN DNIS#C#NN - 235-2855
CIl"Y CF YVHHAT.RfDGE Date :10118/85
750 YIE$T 29TFF AVENtJE
VYHEAT RIDOE, CO 8fi216
PropeAy Owner : MACDONAI,D BARBARA ANN
Pr4perty Address : 7879 46TH AV Phone :
Conhadqr License Na : 18588
CompBng Golumbirte Electric Co. Phone : 904 3262
OWNER/CONTRAGTbR Sf6NATURE OF UNDERS7ANDING AND AGREEMENT CpnstruCtion Value : 8150•00
1 nwoipv o+rtMr aw ahe esmack eiahusoes aroowe4 br tlda aamA aoak.non are aaurau, Permk Fee . S25.00
(tlYVP1ER)(CONTRAC7oR) 3-~-
Dsecnipqon : REPLAGE METER BASE AND RISER
BUILDING DEPARTMENT USE ONLY
rcppmrai :
Zaning :
~
: Approval :
npprovaa :
O¢cupsncy :
E1eCtrica0 Licena8 No
Corvahy ;
. ~.(8)
(Sl
(e) '
Chjl
WaNs : Roof
Plumbirrp Lkense No :
Gompany :
Expiration Date :
Approvat :
~ r 10~
1nd y
iwra
Stories
Pian Review Fea :
$OAD
Use Tax :
$2.25
Total s
$2726
Residential Units;
Mechanical4k:ense No :
Company :
Expiradon Date : ,
Approval : ~
m aa u wdea Eo Ifre uws am. StO. af caaaao ma ro ab zmxq beworv dws fmm a~ua°s me «(s) ns adft .imarizaar w.parwea «mrmelH ~e4WsM, ttdwqe~ = a~tt Mppruipn a WM~an~me~nt
Mstl ane (9) Yer•
N^f~°t and Y~iNNA iecetra wAtlan approvM on kepecdon cuE 6elbro conetrued Oo be a pemdt fw. nu an aqprovv wrY vklMbn ot the provitlana
THIS PERMR YALID ONLY WO1EN SKiNEC BY THE CMIEF BiJ14DIN0' INSPECTOR
CALL: 234-8933 24 HOtfRS PRIOR TO iNSPECTtON
mm
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION DIVISION - 235-2855
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Building Permit Number :
Date : -`~S-
Property Owner
Property Address
Contractor License No.
Company
79 7
ColuM ~ n.~
(10
~
00
Phone : 21 "5 S 0 ~
Phone : 90 v 3 Z(' z
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Construction Value : i S~
I hereby certify that the setback distances proposad by this pertnit application are accurate, pgrmlt FEE :
and do not vlolate appliwble ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easaments or restrietions of reeorcl; that all measurements shown. and allegatlans
matle are accurate: that 1 hava read and agree to abide by all wnditions printed on this USB TaX :
application, and that 1 assume full responsibility for eompliance with the Wheat Ridge Builtling
Code (U.B.C.) and all other appliwble W Rid e or a s, for work untler this permrt.
J ToWI : ~ ~J•~ ~
(04NNER)(CONTRACTOR) SIGNED DATE/
Description :RE,PI+?-('e
BUILDING DEPARTMENT USE ONLY
Approval :
Zoning :
Approval :
Approval :
Occupancy : Walls : Roof : Stories : Residential Units :
Electrical License No 7 Plumbmg License No Mechanical License No :
Company dae'lp'J6/,(e Company : Company :
Expiration Date :/ag7 Expiration Date : Expiration Date :
Approval: Approval: Approval:
_j . Pfans,IT~quf[ad_°,:'1 Pfiths Required _l 'A ! PINWARW
;17 This pertnrt was issuetl m accortlance with the provisions set forth in yopur apP~ication and is subjec[ ro Ihe laws of the Sla[e of Colora0o and to the Zoning
Regulations and BuiiEing CoAe of Wheat Ridge, Colordtlo or any other applicable ordinances of the City.
(2) This permrt shall expue d(A) ihe work authonzed is not wmmencetl within sixry (60) tlays hom issue tlate or (B) lhe builtling authonzed is suspended or
abantlone0 for a penotl of 120 days.
(3) If this permR explres, a new pertnit may be acquiretl for a fee o/ one-0alf the amount normalry reqmred, provided no changes have bean or will be matle in the
original plans and specifiw6ons and any suspension or abantlonment has not exceetletl one (1) year. If changes are matle or if suspenslon or abantlonment
e:ceetls one (1) year, full fees shall he paiC for a new permit.
(4) No work ol any manner shall be done lhat will change tne naNral Flow of water causing a tlraina9e pro0lem.
(5) Contracror shall noliry the Builtling Inspector lwenry-four (24) hours in atlvance for all inspecnons and snall receive written appmval on inspection wrtl belore
pmcee0iin with successrve phases of the job.
(6) The issu of a permit or the approval of drawings and speci(cations snall not be construea to be a permrt for, nor an approval of. any violanon of the provisions
of the b i~ ing CAdES or any Oth2f Oftlin3nCR. Idw. fUle of feguldtion.
;
c,
Chie ilding Inspector For Mayor
HIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR