Loading...
HomeMy WebLinkAbout5855 W. 39th AvenueINSPECTION RECORD L Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection c Z Inspections will not be performed unless this card is posted on the project site Request an inspection, before MIDNIGHT (11:59 Pc/M) to receive an inspection the following business delay PERMIT: �b l b � �� 0 ADDRESS: � �" S W , tl At JOB CODE: PJ6'5- --sk C,A 2 44 Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underaround or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS -P, PERMIT:yk f gU �y%� ADDRESS: %SS WJqg44Vt-'JOB CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 401 Gasline 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. The City of Wheat Ridge _Third Party Form Check List Property Address" Permit Number_ Permit Issued Date Owner Information Property Owner Information Property Owner Address Inspector Information Inspection Company Inspector Name Inspector Contact info. r' 1 - cwt t,.�• 1 Gary Manlove �5A�5ff� P0, PAY 213 EM lulespx. C0 0'JI IB Cc" 7M.443.8280 FinaS oyymanleve£J,J,;,n,a coT. Inspector Statement and Acknowlednement f I hearby acknowledge the roof I am inspecting is 6.� 12 or over. All roofs that are under 6112 must be inspected by the City of Wheat Ridge Buiding Dept. y I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as a ty of Wheat Ri ge Policies and Procedure and Manufacturer's recommendati and sp ti ns_ Inspector: Date: �-- Page 1 of 2 Property Owner Statement of Acknowledgement I hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection n lieu of the City of Wheat Ridge Building Division inspection. ropery Owner/Agent: Ago, Date. May 23,2018 This original document and permit card, as Vtell as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W_ 29th Ave Wheat Ridge CO 80033 Draft Date= 7:26;17 The, City of Wheat Ridge Page 2 of 2 Ins p flan Chec c ist Vow The City of Wheat Ridge MID -ROOF Inspection C otes � FINAL itci[;rf Ins ectiotra r7 s.; -A Ej Fail ? 3 pvik' t'"= '-� El Fal( Structural roof components -' N'A F-1 Fai3 p$` Ve~rri#9f that no more than 2 layers of shingles exist Flashing for roof and Walls il-n} Fail If now sheathing is installed verify that it is listed in the ElE]d' Fats permit description (Valuation Must be adjusted) Verify sheathing mail pattern. (See Policy & Procedures) Lam'' L E rel? Crickets and saddles Where needed ^� L-1 KAr E] Fa;R Verify B vent must have Foot same gauge as pipe £� €a;? Verify vent ea *t1:A � rail pS Verify no flashings are damaged or rusted 3 ra;a Fai? Step flashingshall be mind_ of 4X4 �•a._�k-- �'���3 � rat; piece lees- shingle r rte- Verffy scuppers aliok■i for proper drainage Ice and Water shield 2' in heated Wall spaces �s 3 ,- Underlayments must foiloW 2012 IRC 12012 IBC El Fail Verify roof slope for proper drainage d F-1 res; Dripedge shall have Erin of 2" overlap El fVA ` ' " Q Fail Dripedge should extend dozen train 2" past roof deck .:; ,.: } r,sr Dripedge shaft be mechanicaly fastened 12" OC ta:,� .tea n l� Fair gD LB roll roofing shalt not be applied to roof slopes Tess than 2:1.2 slope Exception, detached garages, patios, carp �1 -12 orts, opera on three sides Wily rein. slope of ' ' rata, .6a�--i . E71 Fai? Modified Bitumen, EPC3M, TPO train slope 114--12 slope LJ r w, Above roof insulation R-25 jai? Below roof residential R-38 ?=l raii Below roof Commercial R-32 Cl [71, Fxi? Modified Bitumen: EPDM, TPO min slope 114.:12 slope Must be installed in accordance Wilts the manufacturers specifications- Must have manufactures letter of warranty v� the address on the letter for final inspection Illl t l Roof les Re uiir€*rrden Imetal roof shingles shall not be installed on slope less 3.12 Metal valley flashing Slialf be the sande material as roof .ta _ vEJ ,; Metal valley flashing shalt extend a Min of 81' froln the enterfine .Vith a min_ of 3i4 " high splash divefter rib built-in at the flow line with sections overlapping a. _ue R Re ui fs r a inin_ of �� rats Fail Clay concrete file shall have a train. 2-1/2-12 slope Slopes 4:12 and under require double underla* yment Company Name: JBANSUL ING Company Name: JBA C UL77 G Inspector Signature: Inspector Signature: Date of MID -ROOF Inspection: `Z Date of FINAL Inspection: a L I City of Wheat Ridge l Residential Roofing PERMIT - 201801410 PERMIT NO: 201801410 ISSUED: 05/16/2018 JOB ADDRESS: 5855 W 39th AVE EXPIRES: 05/16/2019 JOB DESCRIPTION: Reroof and Redeck remove and install Owens Corning Duration estate Gray Asphalt Shingles with 11 squares. Pitch 6/12.** Third Party Inspector Required for Mid -Roof and Final.** *** CONTACTS *** OWNER (303)330-8155 WOLAVER ANDREW SUB (303)296-0361 Randy Brothers/Cody Hayes 130240 Elite Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4,070.89 FEES Total Valuation 0.00 Use Tax 85.49 Permit Fee 125.05 ** TOTAL ** 210.54 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved mdroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201801410 PERMIT NO: 201801410 ISSUED: 05/16/2018 JOB ADDRESS: 5855 W 39th AVE EXPIRES: 05/16/2019 JOB DESCRIPTION: Reroof and Redeck remove and install Owens Corning Duration estate Gray Asphalt Shingles with 11 squares. Pitch 6/12.** Third Party Inspector Required for Mid -Roof and Final.** I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorize? to obtain this permit and perform the work described and approved in conjunction with this_permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed a � ,,,that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. .., lt�ClCS Signature -6f OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing, and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and� �pprocedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or gra ntin f a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applic,041 code or any mance or regulation of this jurisdiction. Approval of work is subject to field inspection. h"/ j, Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Lagenia Reimer From: no-reply@ci.wheatridge.co.us Sent: Tuesday, May 15, 2018 1:37 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 5855 W 39th Ave Property Owner Name Andrew Wolaver - Property Owner Phone 303-330-8155 Number (enter WITH dashes, eg 303-123-4567) Property Owner Email andrew.wolaver@gmail.com Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Yes F. Wolaver Contract.pd CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Elite Roofing 130240 303-296-0361 5475 Peoria St., Unit 4-106 kathy@elite-roofs.com kathy@elite-roofs.com TOTAL SQUARES 0f„11 the entire scope of work: `- Project Value (contra(t 4070.89 value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) Yes Pitched roof (2:12 pitch or greater) z ) 3vj-va:� What is the specificitch 6/12 of the PITCHED roo : How many squares are 11 1 part of the PITCHED roof? Describe the roofing Dimensional/Architectural materials for the PITCHED roof: Type of material for the Asphalt PITCHED roof. Provide any additionalRemove composition shingles to deck. Redeck. Replace with detail here on the Owens Corning Duration Estate Gray shingles.�"� description of work. (Is this for a house or garage? Etc) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application 9 and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Kathy Cunningham Email not displaying correctly? View it in your browser. ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234 -5933 Inspection line (303) 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: /:� - Job Address: 1 Permit Number: ❑ No one available for inspection: Time AM/ j M Re- Inspection required: Yes No v �� When corrections have been made, call for re- inspection at 303 -234 -5933 Date: G_- _Inspector: �- DO NOT REMOVE THIS NOTICE INSPECTION RECORD Occupancy /Type 'INSPECTION LINE (303) 234- 5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. tj . C/ r INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIACS COMMENTS: Footings /Caissons Plumbing (Underground) Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service. Lines Water Service Lines r' CONCRETE SLAB FLOOR '- Electrical (Underground) Plumbing (Underground) POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED A:"I1 li nu rMWIVI 1:nc YYLHi OCIC CITY OF WHEAT RIDGE i �97( 303) Building Inspection Division (303) 234 -5933 Inspection line 235 -2855 Office • (303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: L sky !L Job Address: S h : Permit Number: 10 , �wy7 ❑ No one available for inspection: Time 5� AM! Re- Inspection required: Yes DNo When corrections have been made, call for re- inspection at 303 -234 -5933 Date: /h Inspector L i i, X/ DO NOT REMOVE THIS NOTICE e a CITY OF WHEAT RIDGE f Building Inspection Division (303) 234-5933 Inspection line 303) 237-8929 Fax (303) 235-2855 Office INSPECTION NOTICE Inspection Type- job Address: I Permit Number: n,01711)A;/c / AM/PM - No one available for inspection: Time 1 P NO Re-Inspection required: Yes action at 303 5933 * When corrections have been made, calf for re-insp Inspector'. Date: 3 THIS NOTICE DO NOT REMOVE " : City of Wheat Ridge or' Residential Remodel PERMIT - r4oo 100897 PERMIT NO: 100897 ISSUED: 04/09/2010 JOB ADDRESS::: 5855 W39TH AVE EXPIRES: 10/06/2010 s; DESCRIPTION::: -Bathroom remodel CONTACTS owner 720/201-4947 Britta Fisher gc 303/421-8711 Gerard/James Nealon 01-9764 Cress Kitchen & Bath sub 303/232-8650 Jimmie A. Gill 01-8958 Edgewater Electric. sub ' 303/455-4307 Greg Barbero 01-.7178 Good Plumbing Service Co.,.'. Inc PARCEL -INFO ZONE - CODE : UA USE : UA SUBDIVISION:. 0428 BLOCK/LOT#: `0/ r FEE SUMMARY ESTIMATED PR CT'V ON: 10,587.0.0 FEES Permit Fee 253.90 Plan Review Fee 165.04 Total Valuation .00 TOTAL 418.94 Conditions: KC: Approved. per plans and notes onplans. Must comply with 2003 TRC, 2005 NEC, x and all applicable City of 'Wheat Ridge Municipal Codes. Subject to field: inspection. 1;- I hereby certify. that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of. Wheat Ridge or covenants,. easements or restrictions of record;`. that all. z; measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this 1 application and that I assume full'. responsibility for compliance with the Wheat Ridge Building Code (I.B.C). and all other.. g" applicable Wheat R I dg Ordinances, for work under this permit. Plans subject to, field inspection. i~. ~ ~9YrLr7 ~~3~i ' Signature of contractor/owner . date 1. This permit was issued in accordance with the. provisions set forth in your application and is subject to the. laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado orl any other applicable ordinances ofi. the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration u'. date. An extension may.. be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of. one-half the amount normally required, provided no K- changes have been or will be madein the original plans and specifications and any suspension or °abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. ' P 4. No :work of any manner shall be done that will change the natural flow of water causing ;a drainage: problem. 5. Contractor shall notify the Building inspector twenty-four (24) hours in advance for all inspections and shall receive. az written approval on inspection card before proceeding with successive phases of the job. 6 The issuance of wr Y ontheoapp the roval of drawings and specifications shall not beconstrued tobe a permit for, nor FFINSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855,'REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY110 1 iprovisions of the buildmg codes or any other ordinance, law; rule or regulation.Allplan review to field inspections. asapproval of, Signature of Chiefs Building Official date W=t 1 Cig Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Building Permit Application Date: Plan# Permit # RIP Property Address: ,78~J A Property Owner (please print): 2)R 1 7-rA Phone:72-0 -z0/- 19 47 Mailing Address: (if different than property address) Address: 38ty A City, State, Zip: Contractor: [ i j G~ Iq ) i7~ Contractors City License / Phone: Sub Contractors: Electrical: up~ ~ IZ )~Z-FG Plumbing: ,.~-77OoD PyJMt3lrl6 Mechanical: City License # City License # O l7 I 8 City License # Description of work: ~`1 I'Vz/-hDI~L Contract Value: $ 208`2 Squares BTU's Gallons _ Amps Sq Ft. OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: 6aQ-A(R-)7 SIGNATURE: Z-/L DATE: ZONING COMMENTS: Zoning: Reviewer: DEPARTMENT USE ONLY BUILDING DEPARTMENT OWENTS: 4 a-P ))EA P14WS C9oV Reviewer. Gfgj-`o PUBLIC WORKS COMMENTS: OCCUPANCY: Reviewer. FIRE DEPARTMENT:: ❑ approved w/ Comments ❑ disapproved U no review required Bldg Valuation: $ ®fi ✓~"~~100 19,07 00 Review Fee (due at time of submittal): O ~ o o < o rn ~ ~ o 0 o ~ O W ~ ~ fN9 W w ry~yy ~l u. N ~ N G 00 W 9 OWO G ro7 O N W rr W a ~ o CCD N a h O ~ N O O CD 0 ° a ~ P- • w tC N m ti ~~yy N a C-D o a n o o - C 5 Ro CD E a ~w ~ o _ 3L 0 0 c y w ti S. ~ 1 co' f R r w 7 m -r F N O O r~yC~y a O R7 O y lc~ o~ O N O O w Since 19481 GS VOICE (303) 421-8711 www.CressKitchenBath.com kit en & ath FAX (303) 423-3827 Cabinets - Vinyl Floors - Carpet - Ceramic - Counter Tops • Plumbing Fixtures 6770 W. 38th AVE. **PROPOSAL** Job Number: 36342 HALL BATHROOM #2 Job Site: WHEAT RIDGE, CO 80033 Prepared for. BRITTA & RYAN FISHER 5855 W. 39TH AVE. WHEAT RIDGE, CO 80033 (H) (720) 201-4947 (F) (w) (720) 259-1030 (0) (720) 201-4947 CELL Style name Quote Date: 4/7/2010 Good Until: 5/7/2010 BRITTA FISHER 5855 W. 39TH AVE. WHEAT RIDGE, CO 80033 (H) (720) 201-4947 (F) (w) (303) 263-5496 (O) Color name Units Price Estimate LR REMOVAL 6.00 0.00 0.00 Tff CUST^MERWILL REMOVE THE EXISTING TILE FLOOR, TUB, TILE, VANITY, C-TOP, MIRROR, LIGHT, TOILET WALL BOARD AND CABINET DOOR W/CASING. SALVAGE THE EXISTING TOILET FOR RE- INSTALLATION, THE EXHAUST FAN, THE WINDOW SILL, THE WINDOW AND THE DOOR. CUSTOMER WILL DISPOSE OF THE OLD MATERIALS. THEY MAY USE OUR DUMPSTER FOR THE TUB IF BROKENon,. DOWN. "BRING IN A PC. OF THE OLD DOOR CASING TO HAVE IT MATCHED- 2X4 3.00 6.99 20.97 INSTALL BLOCKING FOR A GRAB BAR FOR IN THE FUTURE. SEE IF THERE IS A PLACE TO FRAME IN A RECESSED SHAMPOO SHELF ON THE WET WALL AND FRAME IT IN. CUSTOMER WILL MAP OUT WHERE BLOCKING IS TO BE INSTALLED FOR THE PAPER HOLDER, TOWEL BAR, TOWEL RING AND THE ROBE HOOK. 1X8 CLEAR PINE S4S 8.00 4.99 39.92 FILL IN THE RECESSED AREA IN THE LINEN CLOSET TO BLOCK OFF FROM THE HALL CLOSET AND INSTALL A SHELF ON THE BATH SIDE AT THE SAME HEIGHT AS THE EXISTING SHELF, EXTEND TO THE DOOR OPENING. EXTEND THE TOP SHELF TO THE DOOR OPENING ALSO. BUILDING MATERIALS 1.00 5.00 5.00 USE STOCK PLY OR PART. BOARD. FRAME IN A RECESS AREA IN THE BATH SIDE OF THE LINEN CLOSET APPROX. 8" DEEP TO THE THIRD SHELF- LABOR ELECTRICAL 0.13 595.00 77.35 INSTALL AN OUTLET IN THE 8" RECESSED AREA OF THE BATH SIDE OF THE LINEN CLOSET FOR RECHARGEABLE ITEMS. IF POSSIBLE, PLEASE INSTALL A TOTAL OF 2 OUTLETS, ONE ON THE BOTTOM SHELF AND ONE ON THE SECOND SHELF AREA. LIGHT FIXTURE 1.00 259.00 259.00 #6463-NI STRUCTURES, INSTALL A NEW LIGHT OVER THE LAV. LABOR PLUMBING RAISE THE SHR. HEAD OUTLET APPROX. 6". MISC. PLUMBING MATERIALS SHUT OFFS STRAIGHT 1/2" X 1/2" 114 TURN BALL VALVE WITH A BLEEDER. IN THE CEILING OF THE BSMT_ BATH. 2.00 595.00 1,190.00 1.00 59.00 59.00 1.00 16.95 16.95 REPLACE THE STOP TO THE EXTERIOR SILL COCK Page 1 of 4 **PROPOSAL** Job Number. 36342 Quote Date: 4/7/2010 Style name Color name units Price Estimate DELTA VALVE BODY SCREWDRI NOT APPLICABLE 1.00 59.95 b9.9b ROUGH IN THE NEW TUB/SHR. VALVE FOR THE TUB. LAHARA, MONITOR 17 VALVE T CHROME 1.00 117.20 11720 INSTALL NEW TUB/SHR. VALVE TRIM THREE FUNCTION HAND HELD CHROME 1.00 176.80 176.80 INSTALL A NEW HAND HELD SHR_ WALL ELBOW CHROME 1.00 36.95 36.95 INSTALL THE HAND HELD AS THE ONLY SHR. HEAD. TUB SPOUT, W/DIVERTER CHROME 1.00 45.45 45.45 ENAMELD STEEL TUB 60X30X15 WHITE 1.00 219.00 219.00 INSTALL A NEW BATH TUB. DRAIN & OVERFLOW STD TUB CHROME 1.00 59.49 59.49 ABS TRAP AND WASTE 1.00 32.34 32.34 REMOVE THE LEAD WASTE AND THE DRUM TRAP. TIE IN TO THE EXISTING CAST IRON WASTE BELOW. EXISTING COPPER SUPPLY LINES. 0.01 0.00 0.00 s` CUSTOMER WILL INSTALL NEW SHEET ROCK ON THE WALLS THE BATH, AND WILL REPAIR THE : E ge~o CEILING IN THE BSMT. BATH AS NEEDED AT THE OLD DRUM TRAP. LABOR DRYWALL 0.01 0.00 0.00 CUSTOMER WILL TAPE, FINISH AND RE-TEXTURE THE WALLS AND THE CEILING, AND WILL REPAIR THE CEILING IN THE BSMT. BATH BELOW- CUSTOMER WILL PRIME AND WILL PAINT 5e'v , 6,& ULTRA-BOARD 4.00 19.95 79.80 CASH SALE, THEY ONLY NEED 2 SHEETS. CUSTOMER WILL INSTALL AROUND THE BOTTOM OF THE TUB/SHR AREA AFTER SETTING THE BATH TUB_ CASING SOLID PINE 24.00 0.00 0.00 RE CASE THE BATH SIDE OF THE BATH DOOR. TRY TO MATCH THE CASING AS CLOSE AS POSS IBLE, WITH STOCK MOLDING. JEFF H. BROUGHT IN A PC. STO MATCH. LABOR STAINING 0.01 0.00 0.00 STAIN AND FINISH TO BLEND WITH THE NEW CABINETS- MEDALLION, CHERRY, CHESTNUT. US E STOCK CHESTNUT STAIN. CABINETS, MEDALLION 1.00 1,448.00 1,448.00 VENICE, CHERRY, CHESTNUT. INSTALL A NEW VANITY CABINET AS PER DRAWING. ADULT HEIGHT AHCVSB36, MIRROR MOLDING, FACE FRAME AND DOOR AND DOOR PROFILE FOR THE LINEN CLOSET. MIRROR, PENCIL EDGE 7.50 14.95 112.12 INSTALL ABOVE THE LAV. TO BE FRAMED TO MATCH THE VANTIY CABINET HARDWARE 6.00 9.95 59.70 GALLERIA, #24002-SN, INSTALL HARDWARE ON THE CABINETRY MYSTERA COUNTERTOPS 1.00 619.00 619.00 COLOR= BUCKSKIN, INSTALL ANEW COUNTER TOP WITH INTEGRAL BOWL. TOP SET THE LOOSE BACK SPLASH. Page 2 of 4 **PROPOSAL** Job Number. 36342 Quote Date: 4/7/2010 Style name Color name Units Price Estimate LAHARA PAPER HOLDER CHROME 1.00 34.65 34.65 INSTALL A NEW TOILET PAPER HOLDER LAHARA 24" TOWEL BAR CHROME 1.00 39.75 39.75 INSTALL A NEW TOWEL BAR. RE-INSTALL THE EXISTIGN ROBE HOOK THAT IS ON THE JOB. LAHARA TOWEL RING CHROME 1.00 24.20 24.20 INSTALL A TOWEL RING AT THE VANITY CURVED SHOWER ROD 5' CHROME 1.00 69.95 69.95 INSTALL A CURVED CURTAIN ROD. LABOR 11.00 2,996.00 2,996.00 MISC. NON TAX 96.00 4.89 469.44 SEALER, GROUT PINT 1.00 0.00 0.00 PLEASE LET THE CUSTOMER USE AN OPEN CONTAINER TO SEAL THE FLOOR GROUT. N/C. Product 5,440.74 Sales Tax 413.50 Labor 473279 ~ otal 10,587.03 } Payments Received -3,500.00 Balance Due 7,087.03 Any changes from the above involving extra cost of material andfor labor will become an extra charge over the above sum. If the Contract is not paid within 30 days of invoice date customer agrees t0 pay all collection costs and attorney fees to secure payment, and carrying charges of 1.5% of the unpaid balance per month, which is 18% per annum. Payment terms-- 113 deposit, 1/3 at start date, 113 upon completion. Permits are not included in this Contract unless otherwise specified. It is further agreed that The Finn shatfnot be liable for any delays occasioned by elements, strikes, fire, inclemency of weather, acts of commission of any persons, or other causes beyond the control of The Fmw Accepted by: Approved by: Jerry Date: Page 4 of 4 4 o`` WHE4rq. City of Wheat Ridge °o~oRa~° Residential Mechanic PERMIT - 071050 PERMIT NO: 071050 ISSIIED: 09/26/2007 JOB ADDRESS: 5855 W 39TH AVE EXPIRES: 03/24/2008 DESCRIPTION: RPELACE 40 GALLON GAS WATER HEATER - CONTACTS GC 303/430-1911 Felipe Ramos 02-1881 Plumb Pros OWNER 303/463-4653 RYAN FISHER PARCEL INFO ZONE CODE: UA SUBDIVISION: 0428 USE: UA BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 975.00 FEES Permit Fee 50.40 Total Valuation •00 Use Tax 17.55 TOTAL 67.95 Comments: SUBJECT TO FIELD INSPECTION I hereby certify that the setback distances propoeed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this applicatioa and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.H.C) and all other applicable wheat Ridge Ordinances, for work under this permit. Plans subject to Eield inspection. Signature of contractor/owner date 1. This permit was issued in acwrdance with the prwisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issve date. Requests for an extension must be received prior to expiration date. z+n extension may be granted at the discretion of the Building Official. 3. If this permit expixes, a new permit may be acquired £or a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and speciEications and any suspension or abandonment has not exceeded one (i) year. If changes have 6een or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases oE the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Signature of Chief Building Offi date INSPECTION REQUEST L2~ : 03)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. OF V'HEqTA ~ ~m City of Wheat Ridge . COtORPQO Residential Roofing PERMIT - 070616 PERMIT NO: 070616 ISSUED: 06/22/2007 r JOB.ADDRESS: 5855 W 39TH AVE EXPIRES: 12/19/2007 f,' DESCRIPTION: T/0 2 layers; Install Cer t. 30yr Landmark, Ice/Water shield. z ^as;. l*** CONTACTS . ~ V owner 720/201-4947 Britta Eisher gc 303/425-1083 Matthew Rock 01-7908 Rock's Roofing F', PARCEL INFO ; ZONE CODE: UA USE: r-3 ~'SUBDIVISION: 0428 ~ BLOCK/LOT#: 0/ FEE SUMMARY ESTIMATED PROJECT VALUATION: 3,.025.00 FEES ~ :Permit Fee 126.50 . Total Valuation .00 (~~19.2dzJ Use Tax 54.45 TOTAL 180.95 ~ Comments: . menfs from fhe m~~~ hnstalfed o pocu ~ that roofn9 mal~flals hame ust shaU be econd ~ BC ~ meet 900 mph three-s onsite for finaf roof inspectt I herebY certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; Chat I have read and agree to abide by all conditions printed on this applicat' riat I assume full responsibility for compliance with the Wheat Ridge Huilding Code (I.s.C) and all other a cable Wh,~idge Or~1f~p~EOr work under this pesmit /Plans subject to field inspection. T 1~permit was issued in accordance with the provisions set.foxth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. This pesmit shall expire 180 days from the issue date. Requests Eor an extension must be received prior to expiration date. An extension may be granted at the discretion oE the Building Official. If this permit expires, a new permit may be acguired for a£ee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specificaCions and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, £ull fees sha11 be paid for a new pesmit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit Eor, nor an appr v of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All eview is subgect to field inspections. of Chie£ date N REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. DEPARTMENT OF PLANNING AND DEVELOPMENT Building Pennit Number: DF WHEqT ~ BUILDING INSPECTION LINE - 303-234-5933 Date: CITY OF WHEAT RIDGE U m 7500 WEST 29TH AVENUE WIIEAT RIDGE, CO 50215 - (303-235-2855) COCORA00 ~~~"CATION Property Owner: -6rL1"kGC, TvsL'z.t- PropertyAddress: $S'5z5- Phone:74~) .ZO Coniractor License No.: soFP Company: Phone: 3c~3 L/25 /O $3 AND AGREEMENT I hereby ceRify thatthe setback distances proposed by this pemit appiication aze accurate, and do notviolate applicable otdinances, rules or regulations ofthe City of Wheat Ridge or wvenants, easements orresViclions ofrecord; that all measurements shown, and ailegations made aze accurate; that I have read and agree [o abide by all conditions printed on this application and [hat I assume full responsibility for compliance with the Wheqt Rid?e Building Code (U.B.C) and all other applicable Wliea[ Ridge Ordinances, for work under this peimit. I , - /I (OWNER)(WNTRACTOR): Construction Value:$ Lic~, ZS- Pernut Fee:$ Plan Review Fee:$ Use Tax:$ TOt&l: $ Description:'R~evl~ove. 2 exi~ltincJl (~,q C5 Gex-%0Z4tke<'-d !~)-~fc-~Q-+~~"^~ k L1 ~ BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONING COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: Elechical License No: Plumbing License No: Mechanical License No: Company: Company: Company: Expiration Date: Expirarion Date: Expiration Date: Approval: Approval: Approval: (1) This pemit was issued iu accordance witli fhe provisiws set forth in yoiv application mmd is subject ro Flie laws of fhe State of Colorado and ro Hie Zoning Regulafions and Buildivg Codes of Wheat Ridgy Colorado or mmy otlier applicable ordinavces of ihe City. (2) Tltis pemit shall expire if (A) tLe work authodzed is not commeuced vriUiin sixty (60) days from issue date or (B) tlie builNng authorized is suspended or abandoned for a period of 120 days. (3) II this pemit exp'ves, a new pemit may be acquired for a fee of oue-lialf the amount normatly required, provided no changes have been or will be made in tUe origi¢al plans andspecificafions aud any suspension or abandonment hu no[ exceedeA one Q) year. Ifchanees have been or ifsuspension or ahanAnnmenl exceeds one (1) yeaz, full fees shall be paid for a new pemi[. (4) No work of any mauner shall he doue that wID change ihe nahvat flow of water causing a drainage problem. (5) ContractorshallnotifytheBuildingluspectorN+enty-foiir(24)lionrsinadvanceforatlinspecfionsandshallreceivewrittenzpprovaloninspecrioncard6efore proceedi¢g wiih successive phases of the job. (6) The issuance of a peimit or the approval of drawings end specifications shall not be conshued to 6e a pemit for, nor an approval of, any violation of the provisions of the building codes or any otlier ordinance, law, rvle or regulafion. Chief Building Inspector ^r , vEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 6494 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner : Property Address: 5855 W.39th Avenue Phone: 420-9146 Contractor License No. : 19475 Company : NIETO'S ELECTRIC, CO Phone : 455-1714 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT . I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all contlitions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building . Code (U.B.C J and all other applicable W at Ridqe ord/i~7ync~esfor work under this permit. ' . , . ~ tipr....:C.~~t':YJ1~JI Description : Upgrade serufc2 tY1 ~DO~m~s Construction Value : $$50.00 Permit Fee : $45.00 Plan Review Fee : $0.00 Use Tax : $12.75 Totai : $57.75 Use: BUILDING DEPARTMENT USE ONLY Approval: Zoning : Approval: SIC _ . _ ~ _ . . . Sq. Ft. : Approvai: Occupancy : Walls : R,oof~, Stories : Residential Units : Electrical License No : Plumbing Lieense No : Mechanical License No : Company: Company: Company: Expiration Date : Expiration Date Expiration Date : Approval : ApprovaL Approval : (1) This permit was issuetl in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Code of Wheat Ritlge, Colorado or any other applicable ordinances of the Ciry. (2) This permit shall ezpire if (A) the work authonzed is not commencetl within sixty (60) days from issue da[e or (B) the builtling au[horized is suspendetl or abantlonetl for a period of 120 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amounl normally required, provided no changes have 6een or will be made in the original plans and specifications and any su5pension or abantlonment has not ezceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notiy the Builtling Inspector hventy-four (24) houre in advance for all inspeclions and shall rewive written approval on inspection card before proceediing with successive phases of ihejob. (6) The issuance of a permit or the approval of drawin9s and specificaUOns shall not be wnsUUed to be a pertnit for, nor an approval of, any violation of the provisions of the building wtles or any other ordinance, law, rule or regulatioa ~ .I( ~ ~ ~ n _ Chief Building Inspector THIS PERMIT VALID ONLY WHEN SIGNEU BY THE GHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION : ~ . , DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : / : /9g, Property Owner : ~~j~J ~/U z~'-G (f '-&''S PropertyAddress: Contractor License No. q47~- CompanY : /v / &j-p i1 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this appliration, and that I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Whe t Ridge ordmances, for work untler this pertnit. (OWNER)(CONTRACTOR) SIGNED ~A ~~DATEJ/~/1 Description: _ „~~e' -y u-~ K ~ / Phone : Y z0 -,7/ 7' 6, Phone ; ~ Ts~ - Construction Value : gp V-~)' Permit Fee : Use Tax : Total: $0.00 Use: BUILDING DEPARTMENT USE ONLY SIC : Sq. Ft. : Approval: Zoning : Approval: Approvai : Occupancy: Eiectrical License No : Company : Expiration Date : Approval: Walis : Roof Plumbing License No : Company : Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval: (1) This pemit was issued in accordance wifh the provisions set forth in yopur applica6on and is subject lo the laws of the State of Colorado and to the Zoning Regulatlons and Building Code of Wheat Ritlge, Coloratlo or any oNer applicable oNinances of the Ciry. (2) This pemit shall erzpire if (A) the work authonzed is not commenced within sixty (60) days from issue date or (8) ihe Duilding authorized is suspended or abantlonetl for a period of 720 days. (3) If this pemit expires, a new pemit may be acquiretl for a fee of one-half the amount noimally required, pmvided no changes have been or will ha made in the original plans anC speci(ca6ons and any suspension or abandonment has not exceeded one (1) year. If changes are made or H suspension or abantlonment exceeds one (1) year, (ull fees shall he paid for a new permit. (4 No work of any manner shall be done that will change fhe natural tlow ot water causing a drainage problem. (5 Contreclor shall notiry the Building Inspector twenry•four (24) hours In advance for all inspec6ons and shall receive written approval on Inspeclion card before proceediing with suaessive phases otNe1ob. (e) The issuance ofa pemit or the approval of tlrawings antl specifiwtions shall not be constNed to be a pemit for, nor an approval ot, any vlolation of Ne provisions of the 6vilding codes or any other ordinance, law, nile or regula6on. Chief Building Inspector For Mayor THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Stories : Residential Units :