Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6895 W 46th Place
City of Wheat Ridge Residential Roofing PERMIT - 201700919 PERMIT NO: 201700919 ISSUED: 05/26/2017 JOB ADDRESS: 6895 W 46th PL EXPIRES: 05/26/2018 JOB DESCRIPTION: Reroof - 34 squares - Atlas Stormmaster Dimensional (DUPLEX) **REVISION** Adding redecking 7/16 in OSB overlay on existing space deck planks; Additional Value: $2,000.00 *** CONTACTS *** OWNER (303)423-6538 KAMIONKA GWENDOLYN K SUB (720)203-2900 Don Dimig 150136 1st American Roofing Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 11,900.00 FEES Total Valuation 0.00 Use Tax 249.90 Permit Fee 236.00 ** TOTAL ** 485.90 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A1/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€ms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Residential Roofing PERMIT - 201700919 201700919 ISSUED: 05/26/2017 6895 W 46th PL EXPIRES: 05/26/2018 Reroof - 34 squares - Atlas Stormmaster Dimensional (DUPLEX) **REVISION** Adding redecking 7/16 in OSB overlay on existing space deck planks; Additional Value: $2,000.00 I, b� my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, app tca le building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this permit.,I-further a that I am legally authorized to include ali entities named within this document as parties to the work to be perfore and that workup be perfo mrmed is disclosed in this document and/or its' accompanying approved plans and specifications. y _1 Signature of OWNER ,,dr CONTRACTOR (Circle one) Date I . This permit was issued -based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or gfarithig of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or finance �latio of his jurisdiction. Approval of work is subject to field inspection. 1 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City Of �Wheat j�id�-e MUNITy DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(a)ci.wheatridge.co.us FOR OFFICE USE ONLY I Date: Add to Permit # a 01 � , 1 (! Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Owner 6S��GVVb, , Property Owner Email: /tin l�2 m ©ti k4- Phone: W-' ' Mailing Address: (if different than property address) Address: 5 -id'" City, State, Zip: r Contact Person: a Phone: Contractor: Contractors City License #: ,� �,/0 Phone: 7 2d -- D3 Contractor E-mail Address:// rz` ,iy ,' 12 &m, o / %1L Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour - 2 hour minimum). Description of revised/amended work: P e, L Sq. Ft./LF Amps Btu's Gallons Squares Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) C(CONTr (AUTHORIZED R ESENTA�TIV\E) of (OWNER) (CONTRACTOR) PRINT NAME: ZONING COMMMENTS- Reviewer: BUILDING DEPARTMENT COMMENTS. Reviewer: PUBLIC WORKS COMMENTS: Reviewer: SIGNATURE: DEPARTMENT USE ONLY PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required DATE: 62 — G z' --Il OCCUPANCY CLASSIFICATION: Building Division Valuation: $ - , City of Wheat Ridge Residential Roofing PERMIT - 201700919 PERMIT NO: 201700919 ISSUED: 05/26/2017 JOB ADDRESS: 6895 W 46th PL EXPIRES: 05/26/2018 JOB DESCRIPTION: Reroof - 34 squares - Atlas Stormmaster Dimensional (DUPLEX) *** CONTACTS *** OWNER (303)423-6538 KAMIONKA GWENDOLYN K SUB (720)203-2900 Don Dimig 150136 1st American Roofing Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,900.00 FEES Total Valuation 0.00 Use Tax 178.20 Permit Fee 204.30 ** TOTAL ** 382.50 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding Al/z-inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturerioms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201700919 PERMIT NO: 201700919 ISSUED: 05/26/2017 JOB ADDRESS: 6895 W 46th PL EXPIRES: 05/26/2018 JOB DESCRIPTION: Reroof - 34 squares - Atlas Stormmaster Dimensional (DUPLEX) I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further a -sS that I am le ally authorized to include alI entities named within this document as parties to the work to be perform and that work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWN o CONTRACTOR (Circle one) Date I _ This permit was i sue ased on the information provided in thepermit application and accompanying plans and specifications and is subject to the cont nce with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief wilding Official `.1 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. City of WheatAe COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(cDci.wheatridge.co.us FOR OFFICE USE ONLY Date:/� l fi '� J Add to Permit # f q, Qo� I', '(( Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Owner Property Owner Email: 'Pla�6 4- 410 rvev rCf6;qi©vi Mailing Address: (if different than property address) Address: 97,02, �Y'�r ; rGle- , State, Zip: ��� �/�l i SIS 7�'�'' K06 2— 33 Phone:.-3"�(23- 6 Contact Person: Unn H l M it q Phone: :2,20 `111v S "��� Contractor:�V� l I Contractors City License #: Contractor E-mail Address: /T Phone: -12-94::�6 Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour - 2 hour minimum). Description of revised/amended work: Sq. FULF Amps las S�ormrnus� ��%�, Btu's Gallons Squares _� Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE. (OWNER) (CONTRACTOR) or (AUTHORIZED _ RESEN ) of (OWNER) (CONTRACTOR) PRINT NAME: , / SIGNATURE: DATE: . ZONING COMMMENTS: Reviewer BUILDING DEPARTMENT COMMENTS: Reviewer PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Requirec Sanitation District ❑ Received ❑ Not Required DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ CITY OF WHEAT RIDGE Building Inspection Division r� (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Y" f 0 Job Address: 6175 IV 96L' rL Permit Number: 2 01 ?®U !/ % �«�1 Ul ZzP _ Ii" -M 4219 ALL -j SP_/I'nLING- `TD eaCo rC tet` ❑ No one available for inspection: Time AM OP Re -Inspection required: Yes No *When corrections have been made, call for re -inspection at 392-234-5933 Date: Inspector: DO NOT REMOVE THIS N ICE i CITY OF WHEAT RIDGE -ABuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Por L �%`� L Ac A F Job Address:LT J yd Permit Number: 20 1�'(90 XIR ❑ No one available for inspection: Times . �> AM/PM Re-Inspection required: Yes f No When corrections have been made, call for re-insrpection at 303-234-5933 ri Date:f fir:- � `' Inspector: DO NOT REMOVE"'THIS NOTICE 1* � 4 CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: A� )1) Job Address: 6895 W Permit Number: 20+ 1 UCS ,�� �'�,' ❑ No one available for inspection: Time 6 Z AM PM Re -Inspection required: Ye( e rNo * When corrections have been made, call for re -inspection at 303-234-5933 Date:L'2 II-) Inspector:ti rb � DO NOT REMOVE THIS NOTICE DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 14782 BUILDING INSPECTION LINE - 303-234-5933 Date : 11/13/02 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) Property Owner: KAMCONKA Property Address : 6895 W 46TH PL Contractor License No. : 19402 Phone : 423-6538 Company : Aaark Heating & Air Conditioning Phone : 431 8015 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby cedify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Ridge or covenants, easements or restrictions of record; thal all measurements shown, and allegations made are accurete; that I have read and. agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the W heat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit. (OW N ER)(CONTRACTOR) Description : REPLACE FURNACE Construction Value : $1,810.00 Permit Fee : $66.20 Plan Review Fee : $0.00 Use Tax : $21.72 Total : $$7 92 Use : jita BUILDING DEPARTMENT USE ONLY ZQnfng Ctfi~►imeqtst! SIC : Sq. Ft. : Approval : Zoning : Biail41ngt~4mmeats: Approval : Publid Wor'ks Coa6 ents: APProval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : 19402 Company : Company : Company : Aaark Heating & Air Conditioning Expiration Date : Expiration Date : Expiration Date : 11/15/02 Approval : Approval : Approval : OK/KS (7) This permit was issued in accordance with the provisions set forth in yopur application and is subjecl to the laws of the State of Colorado and to the Zoning Regulations and Building Code of W heat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authonzed is not commencetl within sizty (60) days from issue date or (0) the building authorized is suspended or abandoned Por a period of 120 days. (3) It this permit expires, a new permit may be acquired for a fee of one-hal( the amount normally required, provided no changes have been or will be made in the original plans and specifcations and any suspension or abantlonment has not exceeded one ('I) yeac It changes are made or if suspension or abandonment exceeds one (1) year, full (ees shall be paid for a new permit. (4) No work o( any mannar shall be done that will changa the nalural flow of water causing a drainage problem. (5) Contractor shall noti(y the Building Inspector hventy-four (24) hours in advance for all inspections and shall receive wrinen approval on inspection card be(ore proceediing with successive phases of the job. (6) Th i9s ance of a uwmit or the approval of drewings and specifications shall not be consimed to ba a permit for, wr an approval of, any violation of the ws~n ding codes or any other ordinance, law, rule or re9ulation. ~ Chief Buildi Inspector DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Property Owner: Property Address : Contractor License No. : Company ~_•,q~. 68 r 5-&1/ 1? 4,C) -2-- ~ ~6,*T l/-12-OL Phone : 4712,3 6,~3g, Phone : ~/5/ l OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, ruies or regulations of the City of Wheat Ridge or covenants, easements or restrictions of recortl; that all measurements shown, and allegation made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility qr compliaace W the Wheat Ridge Builtling Code (U.6.C.) and all omer appiicable"'~Ife dge ance or work under inis permit. (OWNER)(CONTRACTOR) SIGN ~ Description : v ConstructionValue:l U Permit Fee : ':16 ? s Use Tax : ~ 7 L Totai : BUILDING DEPARTMENT USE ONLY Approval : Zoning : ~Ildl° i~' df~!~~ Approval: ~11#lxlt~`ritd~lt§~i~o entsi Approval : Occupancy : Walls Roof : Stories : Residential Units : Electrical License No : Plumbing License No : Mechanical License No : Company: Company: Company: Expiration Date : Exoiration Date : Exoiration Date : Approval : Approval : Approval : ~P_,,' t j m,wir~4~°: 1 I { Pl~ns"R~quired~t, 1 ~ , (1) This permit was issuetl in aaordance with the provisions set fotlh in yopur appliwtion and is subject to itle laws of Ihe Stale of Coloratlo and to the Zoning Regulations and Building Code of Wheat Ridge, Coloredo or any other apDlicable ortlinances of the Ciry. (2) This permlt shall expire if (A) Ue work authonzed is not wmmencetl within sixty (60) days from issue date or (B) the building authonzetl is suspentletl or abandoned for a penotl of '.20 days. (3) If ihis pertni[ expires, a new ~ertnit may be acquired for a fee of one-half the amount normally required. provitletl no changes have been or will be matle in the original plans and specifiwt ms and any suspension or a0antlonment has not exceetletl one (1) year. I( changes are matle or if suspension or abantlonment exceetls one (1) year, (ull fees shall be paitl fora new pertnit. (4) No work of any manner shall be tlone that will change the naturel 8ow of water causing a tlreinage problem. (5) Coniractor shall notify the 3uiltling Inspector twenry-four (24) hours in atlvance for all inspections and shall receive written approval on inspection carA before proceetliing with successive phases of the job. . (6) The issuance of a permit or ihe approval cf tlrawings and specifcations shall not Oe wnsVUetl to be a pertnit for, nor an approval of, any vioiatlon of ihe provisians of the buildinp cotles or any other ortlinance, law. rule or regulation. Chief Building Inspector For Mayor THIS PERNIIT VALID ONLY INHEN <IGNED P; THE CHIEF BUII DING INSPECTOR AND MAYOR CALL: 234-51•33 24 H jURS PRIOR TO IN5'ECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : BUILDING INSPECTION LINE - 303-234-5933 Date : CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) 13318 1 /7/02 Property Owner: Property Address : 6895 W. 46th PI Contractor License No. : 18091 Phone: 303-423-6558 Company : Sin Jac Electric Phone : 424 3898 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby ceAify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are acwrete; that I have read and agree to abide by all conditions printed on this application, and thal I assume full responsibility for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable Wheat Ridg%ordinances, for work under this permit. 1 (OWNER)(CONTRACTOR) SIGNED ~~C'~~ DATE /-J- 6' Description : Service change-125 amp on duplex ConstructionValue: $1,095.00 Permit Fee : $41.80 Plan Review Fee : $0.00 Use Tax : $16.43 Total: $58.22 Use BUILDING DEPARTMENT USE ONLY AIN"A SIC : Sq. Ft. : Approval : Zoning : Approval: " elo :~MON:.:_.. W Approval : Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Company : Expiration Date : Approval : Plumbing License No : Company: Expiration Date : Approval : Mechanical License No : Company : Expiration Date : Approval (1) This permit was issuetl in accordance with the pmvisions set fotlh in yopur applicalion and is subject to the laws of the State of Colorado antl to the Zoninq Regulations and 8uilding Code of Wheat Ridge, Colorado or any other applicable ortlinances of the Ciry. (2) This permit shall expire if (A) the work authorized is nol wmmenced within sixry (60) days from issue tlate or (B) the builtling authorized is suspendetl or abandoned for a period of 120 days. (3) If this permit expires, a new permit may be arquired for a fee oF one-half the amount normally required, provided no chanqes have been or will be made in the original plans antl specifcations and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work ot any manner shall be done that will change the naNral flow of water causing a tlrainage problem. (5) Contrector shall notiy the Building Inspeclor hventy-four (24) hours in advance far all inspections and sha0 receive written approval on inspection cartl before proCeediing with successive phases of the job. (6) The issuance of a permit or the approval of drawings antl specifcations shall not be consimetl to be a permit for, nor an approval of, any violation of the provision f the bwdes or any other ordinance, law, mle or regulation. C U I I DEPARTMENT OF PLANrIING AND DEVELOPMENT Building Permit Number: BUILDING INSPECTION LINE - 303-234-5933 Date: ~ CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 - (303-235-2855) ~~CORADO 1~p APP~~d i ON Property Owner: G' (4)C AJ KA mi a Iv kA Property Address: (o p 9'~- GJ ~/G PG W 2 phone :,T ' YZ 3- 6SS~ Contractor License No.: Company: .5,nI J/k ~ ~t- ercT. Phone: .j -5`7-41-2 PIP OWNER/CONTRACTOR SIGNANRE OF UNDERSTANDING AND AGREEMENT I heroby certify that the setback distances proposed by this permit applica[ion aze accurate, CORSYSACYlOII V 31U0:$ Ai~ md do notviolate applicable ordinanas, rules or mgulations of the City of Wheat Ridge or . PeTIIllt Fee:$ covenants, euements or resVic[ions ofrecord; that all measurements shown, md atlegations made aze accurate; that I have read md agree to abide by all condibons printed on this P11II RCV10W F00:$ application and thaz I assume full responsibiliTy for compliance with the Wheat Ridge Building Code (U.B.C) md all other applicable Whea[ Ridge Ordinances, for work under USe TdX:$ thispermit. / / / TOtal:$ (OWNER)(CONIRACCOR):SIGNED w ~ LAle~I 7 Descriprion: O N A BUILDING DEPARTMENT USE ONLY SIC: Sq.Ft.: ZONIN6 COMMENTS: Approval: Zoning: BUILDING COMMENTS: Approval: PUBLIC WORKS COMMENTS: . Approval: Occupancy: Walls: Roof: Stories: Residential Units: Electrical License No: Plumbing License No: Mechanical License No: Company: Si N J.qr- FL ~fc r. Company: Company: Expiration Date: Expiration Date: Expirarion Date: Approval: Approval: Approval: (1) 11tis permi[ was issued in acwrdance witli the provisiovs set forth ia your applicaUOn md is subject to the laws of the S[aro of Colorado and to the ZoNng Regula4ous md Hwlding Codes of Wheat Ridgq Colorado or any otYer applicable ordinavices of the Ciry. (2) T1us pelmit shall up'se if (A) Nie work aut6oriud is not commmced within sirzty (60) days from issue date or (H) the building authorized is suspended or aba¢doued for a period of 120 days. (3) If this pelmit enpires, a new permit may be acqused for a fee of ono-lulf the amouut noimally required, provided ¢o chauges have been or will be made ia the originalplans and specificatiaas md my suspeusiov or abandoument has natexce<ded om (1)year. If chauges have bee¢ ar ifsuspevsion orabandomient exceeds one (1) yeaz, full fees shall be paid for a new permit. (4) No work of auy manner shail be done thac will change the nanual flow of water causing a drainage pmblem. (5) Conhacrors5allvo¢fytheBuild'wglvspectortwenTy-fow(24)howsinadvmceforallinspectionsa¢dshallmceivevrtittenapprovalmi¢spectioncazdbeforc pmceeding with successive pUazes of the jdb. (6) 1'he issuauce of a pamit oc ihe approval of drewings md speci$ca4ons shall not be constcued m Le a pecmit for, am an approval of, any violatiou of the provisions of the bwlding codes or any other ordiaance, law, rule or regulafion. Chief BuIlding Inspector 7ALL 3 TAB ~'12 P17GH ElUilQiMG :t7EPAKt Mtr ~ ~ 1 ~~C . . . ~ . . . . Wgqg ; Rt~Of : Plumbing;Licxns6 No : CampanY :I Expiration Date : Approvsh:' ~ Petmit F8e : Stories : con1PsMY : Expiretion Data a APPtrnral : ~~Nroaw~ea.~aAd~~a~d~eno~sh.wiar~a~+ deaonsN)r~. n~arMm~psauw,~?~ ~ .IOt~pe~iO~iuend~ahaHiecsM1ee'luenapprovVAhkuiW ponaWeC to be a POM*fOr, Iqr mOPpwM d: Ovl vW DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number : Date : Property Owner Property Address Contractor License No. Company r Kq ~o89s-,,° y~ ~~'1 1-7 8~ r-~ -~~o~ OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pertnit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; ihat all measurements shown, and allegations made are accurate; that I have read and agree to abide by all tonditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Builtling Code (U.B.C.) and all other applicable Wheat Ridge ordinances, rk under this pertnit. (OWNER)(CONTRACTOR) SIGNED DATE 1I 179 Description : :Z"5 k-~-<< c .'}u~ 2 ! BUILDING DEPARTMENT USE ONLY ZSIC : Sq. Ft. : Approval : Zoning : Bu-lfd n_, kdft- Approval : PQbI Approval: Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Piumbing License No : Mechanical License No : Company : Company : Company : Expiretion Date : Expiration Date : Expiretion Date : Approval: Approval: Approval: IN [P.I32~~ m ~tl~l 0 ~IafJ~3B8'Q~1LBtlm (t) TTis permit was IssueC in aaoNaxe wilh the praWsiona aet kM in yopur apqiotlon anE is wEject to the laws o( the Stale of CobraCO anC W tM Zoning Requlaliont and BuiWinq Code o1 VMeal Ritlga, Colontlo w any oNtt appirade aNinances ol tlie Ciry. (2) Tliis permit slull expi'e if (A) IAe vrork suUionzed is not commenced wiNin sizty (60) Oays hom issue Aaie M(B) the EuilEing auNWiZed Is SuspenEed or awndoneC (or a period o( 120 Eaya. (3) II Ihia permit enpiies, a new pertnil may Oe acquireE !w a lee o( one-half Ue amount nortnalty repuired, provided no Uanges hava Eeen or will Ee made in the ai9lnal W na arM apadfiwtlons and am suspension w aOanAOnmenl nas iwl ezceetled ona (t) year. tf chanqes are rtutle or il suspension w aCarWOnment ezceeCa ane (1) year. NII (xa shall Oe paiE for a new pertnil. a) No work af etry manner SAall Ee Cone Ilwt will Uanqe the aaNral Ilow o/ water nusirg a Eninage proElem. 5) Contncior slwll rrolify the Building Inspador Nrenly-lour (24) houn in atlvance for all inspections and shall receive wntten aDP(oval on inspection wM Eetwe pocee0iinq wiN auaesaive vhases Of Ihe 7~o0. (e) 7Te luuante ol a permit w it~e aOProva10( Eravnnga and specitwGons sAall rwt Oe conetrutd Io De a pertnil far, nor an approval o( any violalion of the provisions of Na EuilCinq codaf or any oMer oitlinance, law, rule or regulation. Chief Building Inspector For Mayor Phone : '(3 / Q6 s- Phone : ~-2-3 ( s`8 Construction Value : ~a9a Permit Fee : Plan Review Fee : Use Tax : Total : THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION .J1/ i 1 .y ty A g~ ~.ay#~ v y m~~ . . ~i•.. K ~ K;ryY, 7$ 1rNSitNtf~ YtH! ICF:I.~ -r ~ ~ ._.~y{s `^~'-+-...~y"...~• F a.atNI N uFik~u R( PER~~;,` gy i ' p. . ~ ~ ~J~-+C/..~"' $PEGFV NORTN a . ~ ~ G1~ Y f '1• O ( FRONT PROPERIY~.LlNE ..y~.~. t . . . STREET NAMF~___ . ~ (CIRCLE FROYT) N E 5 W ~ St10W DiSTANCES FROM 7HE MAIN 9UILDMG i0 AWOtNING MOUSES, STREETS, OND?ROpER?Y UNES fk! 480VE SNETCH; ~ . SHOW LEAST DISTANCE TO PR07ERTY LINES, NJT MAXIMUM OR MRAGE DISTANCE'"• OWf1EPS NAME ~:I~.!~_ ~I'L IEGAL~0E5CRIP7i0N . COkTHACTOR LIC N0.¢ MEiF.S AND BOUNDS DESCRIPTION ATTA;.HED ~ - . ApDRE PHONEAJDRESS ~•rr - CITY_. ZIPCOD`..WT N0.- -_-_.--BLACK NO _ LOTWIDTN__ DEPTHAREA_SUBOIVISt(NJ____-.---FlUNG . IIi01CATE TNOSE OF THE FOLLOWIN6 OFF-$ITE IMPROVEA5EN7S NOK E%IS71NGCurb N Cwtter__ Str"t Paefnp.__Nbfer_ Sewsr_Stam Ra1rwe- NdVE ARRANGEMENTS BEEN MADE~TO PRCVIDE FOR TF16SE NUT NOW E%ISTING YF.S_!10- ~ ARE THERE ANY S?ECIAL ASSESSMEN75 dGAMST TNIS PROPERTY: YF_S_Np__ QCCUPANCY . z - ,.h,< E%tERIOH MATEA AtWALLS FOOF_ LMi'fS . c~. co~uTr r., e,c n ~~n, of uND r, rn%o Nc ahD acRI[M[Nr PERMI7 FEE R"~,'f ? :4 d~.s'9rr , , .an r ! is p9rm d oOCIICOhCn ara otLUrdto. (Ind dJ n01 viO"C%Ll , , . . . . ~ . . 1 F.. . . . -l ' ~ . , . ~a o: fA . ) 0 li i:I l G~.:YCpUMu.lOBJi1`9pifi Qf lBStmllpll: 0) fJ Is nmf f hore rood ond oqrae fu obiae by ofl ~U1ra' . ~ ] o:~ I'l a 1 .t I n il r apm .Ni~ty tor CompNance wtn fn9 Wnpai Ri40e JB ! rd al r y b a~ T nt rJ o-qa~an ~ fa w,rk untle: Inis perm t ~ ~ , IsWr R) S . . . . . _ ~ . _ _ , ~ . . . . ~ . Pf20 i.Rll' LC~ A i:f~ A(._ . . ' . „ ; PRE'c F.'dTLY 14 uSE is NOt) nc_ow J i .r p - ~ . ~ . _ . . . . . s.~~;:..c,'n.--. . J r, rnFA 9u1LUING COST S. zr- FLECTRICfaL FEI'"diT Pt.UMdW6 PF.RMIT I MECNANICAt PERMIT ci _ - Tr ao - _ _ srnrF rio ciTr uo _ - _ - - . , cirv No 41 nN AEViEH'c[. NOi OHl FI Ari; ki viFWC.L'__ ._l .._q(;(__NOT OY" 7LAN5 H/FJIFVPED_...- _(_,OK)(_._NQT OK)' NrFi;EO riq PI A'+; yEEDED___ ~ NO PLANS IIEECFD_____ . FD I 1, Pl AliS Hs.',pLU RRiO RTO tSSUANft OF I PLANS NCCDED PR;Cn TO ISSUANCE OF /F rA I :lII)NaINCFERMIT MFCNANIC4l PEr7MIT . Y . . . . . _ Ff RMIT 0*O ! 1 RMiI I$SUED 0__ _ _ - _ ' _ 1j i PF H 4tI.0Ur S'. A°i Pf_R Ft ANS NO PEH REQUES' e, r c R f LANi; Np t . .~,t.i.I,^. ;,.c 4uSVr:,ri'.iANDCN41'FIrJMYOf':IGF ~ ASl.Gti,.c_~NJ I_c';:6t5r i'F M CiY I M f UN7 I CI EdHED 8Y JO f 7T ESI I UYT I i' AR . ~ ❑;T qq".ucl~vCT0V ~ ,41 INSPECTI N ECORD INSPECTION REQUEST LINE: (303) 234-5933 Occupant /v Type Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** 17 inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector Comments Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter r i uo Not rour uoncrete rnor 1 o Approval UT i ne moove inspections Underground/Slab Inspections Date Inspector Comments Initials Electrical Sewer Service Plumbing Do Not Cover Underground or Belowlin-Slab Work Prior To Aoproval Of The Above Insnections Rough Inspections Date Inspector Initials Comments Wall Sheathing Mid -Roof r i x "vsC %xlx rT— r-O(L N"e_j Sli1'IC- Lath /Wall Tie to (Z 1 Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation Drywall Screw/ Nail Final Inspections Date Inspector Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof Final Window/Doors 5 L Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. "For low voltage permits - Hlease be sure that rough inspections are completea trom the Tire district and electrical low voltage by the Building Division. ""For Inspection Time Window — Please email insptimerequeSt@Ci.Wheatridge.CO.US by 8:00 A.M. the morning of the inspection with the property address in the subject line of the email. Time window is based on the inspector's route. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issw Protect This Card From The Weather ► ,� Citl .� of Wheat Ride- e .. k'esidential Roofilag prqMIT - 201700919 PERMIT NO: 201:700919 ISSUED: 05/26/2017 JOB ADDj,2SS: 6895 W 46th 1"L EXPIRES: 05/26/2018 JOB DESCRIPTION: Reroot_ 34 square; Atlas Stormmaster Dimensional (DUPLEX) *** CONTACTS *** OWNER (303)423-6538 KAMIONKA''.;..)OLYN K SUB (720).203-2900 Don Dimig 150136 1st American Roofing Co. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEF SUMMARY *** ESTIMATED PROJECT VALUATION: 91900.00 FEES Total Valuation 0.00 Use Tax 178.20 Permit Fee 204.30 ** TOTAL ** 382.50 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€-'s .installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer's technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection.