Loading...
HomeMy WebLinkAbout6260 W. 45th Placei A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Y' ir- -?549 Job Address:-� Permit Number:f ❑ No one available for inspection: Mme - � Re -Inspection required: Yes, No When corrections have been made, call for re -inspection at 303-234-5933 Date: & `�c - 6- Inspector: .1*1_� DO NOT REMOVE THIS NOTICE City of Wheat Ridge E -Res. Siding Replacement PERMIT - 201802447 PERMIT NO: 201802447 ISSUED: 09/05/2018 JOB ADDRESS: 6260 W 45th P1 EXPIRES: 09/05/2019 JOB DESCRIPTION: Replace 7 squares of steel siding on right elevation only per manufacturer&#39;s specifications. *** CONTACTS *** OWNER (303)521-3599 LINVILLE CAROLYN S SUB (303)776-5263 James Hooven 140187 Northern Lights Exteriors *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,000.00 FEES Total Valuation 0.00 Use Tax 105.00 Permit Fee 125.05 ** TOTAL ** 230.05 *** COMMENTS *** *** CONDITIONS *** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. Work shall comply with 2012 IRC & 2017 NEC. Per IRC Sec. R314, smoke detectors are required to be installed in every sleeping room, in hallways outside of sleeping rooms, and on every level of the structure. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further attest that I am legally authorized to include al entities named within this document as parties to the work toe performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying )Tans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting,of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applic code or any finance or regulation of this jurisdiction. Approval of work is subject to field inspection. �-11 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FOR OFF -ICE USE ONLY City, of Date: Wheat I 7TT7 �C.' NjgPMET Plan/Permit Building & Inspection Services Division 7500 W. 29t " Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Plan Review Fee: ! �� Inspection Line: 303-234-5933 �?Y Email permits a('_.ci.wheatridge co us Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ••' Property Address: _. 6260 West 45th Place Property Owner (please print}: Carolyn Linville Phone: Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: ArchitectlEnaineer: Architect/Engineer E-mail: Contractor: Northern Lights Exteriors Phone: Contractors City License #:/ u �U Phone: 303.776.5263 Contractor E-mail Address: NLE-Office@NorthernLightsExteriors.com Sub Contractors: Electrical. W.R City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ® RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION I RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION] WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYST /APP� �NC REPAIR Or REPLACE ENT [10THER (Describe):.,/;TFA , 18Z. ---� f � (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) oe Y Sq. FtAF Amps _._ Btu's Gallons Squares 7 Outer Project Value: (Contract value or the cost of all materials and labor included in the entire project) s 55,000 OWNER/CONTRACTOR SIGNATURE OF UNDEWSTANDINC, AND AGREEMENT I hereh% certifj that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or coxenants. easements or restrictions of record: that all measurements sho%%n and allegations made are accurate: that I have read and agree to abide b% all conditions printed on this application and that I assume full responsibility for compliance %%ith applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application: that'l am the legal o%%ner or have been authorized by the legal o%%ner of the propery to perform the described work and am also authorised b,% the legal owner of an% entity included on this application to list that entity on this application. I. the applicant fir this building permit application, warrant the truthfulness of the information pro%ided on the application. CIRCLE ONF. (AUT ORIZF.D R"E�f'7V' of(0WNER) (CTRACTO ► Electronic 5igw4ture (first and Fast nanx ): Anila Pete DEPARTM ZONING COMMMENTS Reviewer BUILDING DEPARTMENT COMMENTS Reviewer ONLY DATE: 8?/018 OCCUPANCY CLASSIFICATION' Building Division Valuation: $ INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request qn inspection before MIDNIGHT (11:59 PM) to receive an inspectlQnthe following business day PERMIT: ADDRESS: �� CJS JOB CODE: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. - 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground 1 Slab Inspections Date Inspector Initials Comments 201 Electrical/ Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. - 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground j Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing - 304 Sheer Inspection 305 Insulation 306 Mid -Roof j 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Sow err Pan h SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT:klj�)qCk-�ADDRESS:' N,, 44#Pb JOB CODE: Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous (ya Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof� (ya 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 'For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works' 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. The City of Wheat Ridge Third Party Form Check List Property Address Permit Number Permit Issued Date Owner Information Property Owner Information Property Owner Address inspector Information Inspection Company Inspector Name Inspector Contact info. Inspector Statement and Acknowledgement * I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommenda ' s specifications. Inspect �, k?C Date: — 4� Property Owner Statement of Acknowledgement *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Rid!EBding Di 'sion ' spection. Propery Owner/Agent:Date: This original document and perrd, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date: 7/26/17 Please add note to reverse side The City of Wheat Ridge inspection Check List notes Mid -Roof _Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A ❑ N/A A -Pass i4—Pass ❑ Fail ❑ Fail Verify that no more than 2 layers of shingles exist "ass ❑ Fail Flashing for roof and walls If new sheathing is installed verify that it is listed in the N/A ,Pass ❑ rail permit description (Valuation must be adjusted) ❑ N/A Pass F1Fail Verify sheathing nail pattern (Seo policy ,& Procedures) Crickets and saddles where needed ❑ N/A ❑ N/A ass ass ❑ Fail ❑ Fail Verify B vent must have boot same gauge as pipe Verify vent caps ❑ N/A El N/A 1 Pass O-Pa<s ❑ Fail El Verify no flashings are damaged or rusted ,�/A ❑ Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle Verify scuppers ❑ N/A OPass ❑ Fail allow for proper drainage Ice and water shield 2' in heated wall spaces ❑ N/A ,� Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A El N/A Pass ass ❑ Fail ❑Fail Verify roof slope for proper drainage ❑ N/A Pass ❑ Fait Dripedge shall have rein of 2" overlap Dripedge should extend down min 2" ❑ N/A gINIA Pass ❑ Pass ❑ Fail past roof eck Dripedge shall be mechanicaly fastened 12" OC ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of N/A N/A ❑ Pass ❑ Pass ❑ Fail ❑ Fail 1:12 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope N/A ❑ Pass ❑ Fail Above roof insulation R-25 Below roof residential R-38 N/A ❑ Pass [] Fail Below roof commercial R-32 N/A ❑ Pass ❑ Fail Modred Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the leiter for final inspection Metal Roof Shingles Requiremenis N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope Ie55 N/A EJPass ❑fail 3:12 Metal valley flashing shall be the N/A ElPass ❑ Fail same material as roof Metal valley flashing shall extend a min of 8" from th centerline with a min. of 3/4 " high splash diverter e rib built-in at the flow line with sections overlapping a Tile Roofs Requirea min. of 4" ments �,! �N/A EJ Pass ❑Fail Clay and concrete tile shall have a minl 12 slope Slopes 4:12 and under equ re d uble underla yment G The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes Company Name: Inspector signature: Date of Inspection: The City of Wheat Ridge Inspection Check List notes Final Roof Roof Inspection ❑ N/A ❑ Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A ass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A ass ❑ Fail Flashing for roof and walls ass ❑ Fail If new sheathing is installed verify that it is listed in the ❑ Pass ❑ permit description (Valuation must be adjusted) N/A Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/Apf"PEss ❑ Fail Crickets and saddles where needed ❑ N/A rzrpass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A 1`72Pass ❑ Fail Verify vent caps ❑ N/A Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A VrPass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle 10 N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A 9 —Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A `''Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A A Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A O -Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC jjN/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes i less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope N/A ❑ Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R-38 N/A ❑ Pass ❑ Fail Below roof commercial R-32 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less i 3:12 N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material N/A ❑ Pass ❑ Fail as roof Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" _Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double undedayment M* C% The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: C — cl e— Inspector signature: ®ate of Inspection: City of Wheat Ridge Residential Roofing PERMIT - 201709297 PERMIT NO: 201709297 ISSUED: 11/28/2017 JOB ADDRESS: 6260 W 45th PL EXPIRES: 11/28/2018 JOB DESCRIPTION: Residential Reroof: OC Duration asphalt; 5/12 pitch; 17.33 squares *REVISION: Add new sheathing inspection as space decking found prior to installation and after initial permit was submitted. Added valuation.** *** CONTACTS *** OWNER (303)521-3599 LINVILLE CAROLYN S SUB (303)776-5263 James Hooven 140187 Northern Lights Exteriors *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 10,342.61 FEES Total Valuation 0.00 Use Tax 217.19 Permit Fee 220.15 ** TOTAL ** 437.34 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201709297 PERMIT NO: 201709297 ISSUED: 11/28/2017 JOB ADDRESS: 6260 W 45th PL EXPIRES: 11/28/2018 JOB DESCRIPTION: Residential Reroof: OC Duration asphalt; 5/12 pitch; 17.33 squares *REVISION: Add new sheathing inspection as space decking found prior to installation and after initial permit was submitted. Added valuation.— I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specificationst applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermit. I further att st that I am leggally authorized to include all entities named within this document as parties to the work to be performed and that all �ork to beperformed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of P-tN-Eit or CONTIJCTOR (Circle one) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3, If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required mspectjons and shall not proceed "�conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance r gr ting a pe not be construed to be a permit for, or an approval of, any violation of any provision of any applicable �o e ory o antion of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat jdge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(cDci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: 3// Add to Permit # Building Permit Revision/Amendment Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Owner Property Owner Email: ✓� V 0 I dnViIle Mailing Address: (if different than property address) Address: 6� ilk f— ,- , State, 6_� C6MCgs Phone: '5d 3 5 Submitting Company: \� Contact Person: Phone: ';0'3 S3 Contractor: 1-j A'f' Contractors City License #: Contractor E-mail Address: 1�Ktevi0✓'S Phone: 3P 3 - _16111-) 6'Z& 3 CCS i, YI.0 r -F,P_. vim, I 6i i 'Is e X �e r +' D r �dlam-i Please Note: Additional valuation must include all general and subcontracted work to be performed related to the revisions and/or amendments declared in the description of work and which were not included in the original permit valuation. If revisions or amendments increase the original valuation, additional fees will be due at the time of approval. Depending on the scope of work, additional plan review fees may be due upon approval ($60.00 an hour — 2 hour minimum). Description of revised/amended work: Sq. Ft./LF Amps el/ I- cle SOL V-1 ked t-1, -33 S&-, Btu's Squares Gallons Other Additional Project Value: (Must include all general and subcontracted work to be performed related to revisions/amendments described above) $ S0a OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pennit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any pennit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perfonn the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) PRINT NAME: tF ttlEN�-s SIGNATURE: -4A ---Q % DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: PUBLIC WORKS COMMENTS: Reviewer: PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received ❑ Not Required Building Division Valuation: $ City of Wheat Ridge Residential Roofing PERMIT - 201709297 PERMIT NO: 201709297 ISSUED: 11/28/2017 JOB ADDRESS: 6260 W 45th PL EXPIRES: 11/28/2018 JOB DESCRIPTION: Residential Reroof: OC Duration asphalt; 5/12 pitch; 17.33 squares *** CONTACTS *** OWNER (303)521-3599 LINVILLE CAROLYN S SUB (303)776-5263 James Hooven 140187 Northern Lights Exteriors *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,342.61 FEES Total Valuation 0.00 Use Tax 154.19 Permit Fee 172.60 ** TOTAL ** 326.79 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge h Residential Roofing PERMIT - 201709297 PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: 201709297 6260 W 45th PL ISSUED: 11/28/2017 EXPIRES: 11/28/2018 Residential Reroof: OC Duration asphalt; 5/12 pitch; 17.33 squares I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I ame legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this e urther attest that I am legally authorized to include alI entities named ith' this document as parties to the work to be performed that all t;y to be performed is disclosed in this document and/or i acc mpanying approved plans and specifications. Signature of OWNER or LCOWRACTOR (Circle one) Date ! 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 1. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulat�cp f this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reply@ci.wheatridge.co.us Sent: Monday, November 27, 2017 6:27 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process �. varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if ^T your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: �— Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be r� completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a residential roof? How many dwelling units are on the property? Yes Single Family Home, Duplex PROPERTY INFORMATION Property Address 6260 WEST 45TH PLACE Property Owner Name CAROLYN-LI1WILLE Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) Property Owner Email Address 303-521-3599 carolyn.linville@comcast.net Do you have a signed Yes contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed 04 -Linville -WR Signed Agreement.pdf Contract CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Northern Lights Exteriors 140187 303-776-5263 11375 WCR 23, Fort Lupton, CO 80621 Contractor Email Address northernlightsexteriors@gmaiI.com Retype Contractor Email northernlightsexteriors@gmail.com Address DESCRIPTION OF WORK TOTAL SQUARES of the entire scope of work: Project Value (contract value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) 23.0 8500.00 M Pitched roof (2:12 pitch or greater) 2 What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 2/12 & 6/12 2/12: 4.66 SQ 6/12: 18.33 SQ EXISTING: 3 TAB, REPLACE: WITH ASPHALT LAMINATE (OWENS CORNING OAKRIDGE) Asphalt REMOVE AND REPLACE 23.0 SQ OF ASPHALT LAMINATE ROOF MATERIAL ON HOUSE, POTENTIAL RE -DECK SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application Yes Yes Yes Yes 3 and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Mack Yaughn Email not displaying correctly? View it in your browser. Shingle Grade Shingle Style Shingle Color Northern Lights Exteriors Insurance Customer Agreement 30 Yr. Laminate TBD per Homeowner Ridge Material Asphalt Valley O Open O Closed Re -Deck soffit O Open p Closed vents Replace Damaged Metal Edging 2x4 @ Eave/Rake Tear Off ® Layers: 3 Power Vent ❑ Felt 15LB (4sq) ice/Water Per Code Pitch 4/12 Stories 1 -------- -- ® Remove trash from roof, gutters and yard i� Protect landscaping where applicable ® Roll Yard and driveway with magnetic roller ® Furnish permit Prepared For: Carolyn Linville 6260 W. 45th Place Wheat Ridge CO 80033 303-521-3599 carolyn.linville@comcast.net #1) NLE has Permission to mediate with insurance Company all faxes, e-mails, phone calls, financial payments and insurance paperwork. #2) Ice & Water shield in all valleys around chimneys, skylights, vents, pipe jacks and any other roof penetrations. #3) Price done per final approved insurance scope; approval on all supplements prior to work starting. #4) 0% Down 100% upon completion of each trade per insurance paperwork. Company's Limited Warranty: Five years on replacement & one year on repairs Warranty Certificate & Waiver Issued Upon Final Agreement General Contractor: Homeowner acknowledges NL Exteriors as a general contractor and as such will be entitled to % overhead and % profit as allowed by insurance company standards. Insurance/ mortgage company note: I hereby authorize the F— Special Attention Areas insurance and/or mortgage company below to make any checks payable jointly. ❑ Skylights N/A Terms: This agrement does not obligate the homeowner or NL Exteriors in any way unless it is approved by the insurance ® Gutter Damage Replace Damaged company and accepted by NL Exteriors. When "price agreeable" -- is determined, it shall become the final contract price of $Per Final Approved Ins. Scope plus all supplementals and the ® Siding Damage Replace Damaged homeowner authorizes labor and material in accordance with the ,,price agreement' and the specifications set out herein and on ❑ Shutter Damage N/A the second page to accomplish the replacement or repair. ❑ Deck Damage N/A Accepted by the homeowner on: 11 /08/2017 By: Carolyn Linville ❑ windows N/A Payment Method: Pay upon completion of each trade. ® Paint Re -paint Damaged Siding/ Fascia_ ❑ Deck/Fence N/A ❑ A/C N/A ® Misr. Replace Damaged Gable Vent Insurance Information Insurance: State Farm Claim #: 0615608S6 Mortgage: Acct: Phone: v Address: /� Management Approval: Both sides of this document, including the terms and conditions below, and any agreement executed in writing, pursuant thereto, between NORTHERN LIGHTS EXTERIORS (the "Company") and the property owner(s) or property owners representative(s) Carolyn Linville, hereby referred to as the "customer, are subject to the law in effect in the State in which it has been signed and executed. ANY REPRESENTATION, STATEMENT, OR OTHER COMMUNICATIONS NOT WRITTEN IN THIS AGREEMENT, OR MADE IN WRITING PURSUANT THERETO, ARE AGREED TO BE INVALID, AND NOT RELIED ON B EITHER PARTY AND, DO NOT SURVIVE THE EXECUTION OF THIS AGREEMENT. 1. This agreement is subject to the credit and pricing approval of the management of Northern Lights Exteriors. 2 Payment is only due for materials when delivered on Cash Jobs. Payment is due for the remainder of the agreement with completion of each individual trade, including applicable overhead & profit, such as: Roofing, Siding & Trim, Gutters, Awnings & Carports, Interior Repairs, Punch list. In the event a final inspection is required before the "Customer' chooses to pay the "Customer" shall agree to pay the total balance due, less 10% as hold-back until the final inspection and any subsequent punch list is completed. 3 Should default be made in payment of this agreement, a lien will be placed on property and charges will be added from the date of substantial completion at the maximum allowed by law. If placed in the hands of an attorney for collection, the "Customer" will pay all attorney and legal fees. Colorado: Any person or company supplying labor or materials for this improvement to your property may file a lien against your property if that person or company is not paid for their contributions. 4 The "Company" and the "Customer" agree to settle all disputes in accordance with the laws of Colorado and the county in which the agreement is executed. 5. The full amount of all money as specified by an agreed price, or as specified by "Full Scope of Insurance Proceeds" does not include any extras such as carpentry repairs, or any other repairs not specified, and not covered b the "Full Scope of Insurance Proceeds", that is necessary to complete the repair process as required by local building codes, and building officials, or to satisfy cosmetically, the "Customer". 6. If the "Customer" chooses not to pay for a part of the scope of that agreement, an individual line item. Or a trade, the "Customer' releases the "Company" of it's obligations for the performance of that component with regard to the integrity of the building system as a whole. 7. The "Company" will not be responsible for damage below the roof due to leaks caused by excessive wind greater than 55mph, ice damming or hail, at any time during the construction process, or the warranty period 8. The "Company" will not be responsible for slight scratching and denting of gutters, oil droplets in driveways, hairline fractures in concrete, flowers, or minor broken branches on plants and shrubbery. 9. This agreement cannot be canceled once negotiations begin with your insurance company, and/or, material has been delivered to your job-site without written mutual agreement of both parties. 10. If this agreement is canceled by the customer later than three (3) days from execution, "Customer" agrees to pay to the "Company' 25% of the agreement price for. 1) Consulting Services Rendered, or 2) Liquidating fees. If materials have to be returned due to this cancellation, the "Customer" agrees to pay an additional fee of 25% for re-stocking fees. 11 The "Company" reserves the right to supplement the Insurance Company for increases in the "Full Scope of Work", and or, documented price increases. "Customer" agrees to allow these supplements to be paid directly to "Company". 12. All excess materials remain the property of the "Company". 13 "Full Scope of Insurance Proceeds" shall be defined as the full price for repairs and replacements allowed by the insurance company. 14. If any provisions of this agreement should be held invalid or unenforceable, the validity and enforceability of the remaining provisions shall not be affected thereby. WARRANTY OUR STANDARD WORKMANSHIP WARRANTY IS FOR FIVE (5) YEARS. IN ADDITION, WE WILL PROVIDE YOU A WRITTEN WARRANTY UPON RECEIPT AND VERIFICATION OF YOUR PAYMENT IN FULL FOR THIS AGREEMENT. COPIES ARE AVAILABLE FOR YOUR PERUSAL 15. We will not honor our warranty on agreements that are not paid in full PLEASE MA E ALL CHECKS PAYABLE TO: NORTHERN LIGHTS EXTERIORS. Customer Initials City of Wheat Ridge Community Development Department Memorandum TO: Accounting Department FROM: Kim Cook, Building Division SUBJECT: Refund for Permit DATE: December 6, 2017 Reason: Incorrect permit (201709297) was paid for by Contractor. Contractor needs full refund as he paid for someone else's permit. Please refund: Contractors License$ (acct 01-510-00-513) 100% permit fee: $ 172.60 (acct 01-510-00-516) 0% plan review $ (acct 01-550-05-551) 100 % use tax: $ 154.19 (acct 01-500-02-505) Total: $ 326.79 TO: Northwest Roofing 2755 S. Locust Street Denver CO 80222 Thank You! " COO4 Permit Technician ffi )�0S City of Wheat idge 1030 COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29`h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Refund Application Complete this application in its entirety, attach all copies of permits, permit cards (if issued) and receipts that were received at the time of permit issuance. Requests for more than 80 percent of the amount paid will not be approved without prior approval from the Building Official. The refund application must be received by the Wheat Ridge Building Division no later than 180 days after permit issuance. Applications received after 180 days of permit issuance will not be approved. You can mail or hand -deliver all required documents to: City of Wheat Ridge, Attn: Building Division, 7500 W. 29a' Ave., Wheat Ridge, CO 80033. Company Name/Name (to whom check should be made out to): / Y b% 1 �� 0 07 Address: JJCj l0 G_ ct City: t�" State: Phone:0� 'Fax: Permit #: �()J�O I �- Permit Address: Reason for request: Printed Name: Zip: Email: �l u N!I�leayz S� If D'�T �I.�LS "�Ki •Co �i �1L Date:&':�, For office use only /q/ This request has been: Approved Denied Refund Amount: $ \ J C/ Approved by: Date: www.d.w heatridge.co. u s 12/01/17 14:36 City of Wheat Ridge Valuation/Fee Money Postings Page 1 of 2 List/Update cr121_pg.php/Job No: 12256 USER: KCOOK In Update Mode Permit Receipt iNo Payment Fee Amount No Date Code Description Paid 201709297 CDBO18032 11/30/17 PRM Permit Fee 172.60- 201709297 CDBO18032 11/30/17 USE Use Tax 154.19- TOTAL 326.79- City of Wheat Ridge 12/01/17 14:36 Valuation/Fee Money Postings List/Update Page 2 of 2 cr121_pg.php/Job No: 12256 USER: KCOOK GL Posting Summary GL Account Description Debits Credits 01-101 BPS PERMIT PAYMENTS 326.79- 0.00 1ST WR/CK'G 01-500-02-505 BPS PERMIT PAYMENTS 0.00 154.19 USE TAX 3% 01-510-00-516 BPS PERMIT PAYMENTS 0.00 172.60 BUILDING PE] TOTAL 326.79- 326.79 * * . Correction Notice , $ Job Located at 4,6)~ ~ I have this day inspected this structure and these premises and ' have found the following violations of City and/or State laws gov- erning same: : --~v'~ J Z r ) ~ 7~ ~ / ~2c+~ ~ ' ~ You are hereby notified to correct the foregoing violations. : When corrections have been made, cail for inspection. Date '25F . . . . . . . . . . Inspector for Bullding Dept. . DO NOT REMOVE THIS TAG `.FORM WR6-22 DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number : 95-976 BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date :5/12/95 7500 WEST 29TH AVENUE WHEAT RID.GE, CO 80215 PropertyOwner. LINVILLE CAROLYN S Property Address : 6260 45TH PL Phone : 431-9525 Contractor License No. : 17661 Company : Bartels Heating & A/C Phone : 422 3589 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Constfuction Value : $1,250.00 I hereby certify that the setback distances proposed by this permit application are accurate, P8RT1it F22 : $31.00 and do not violate applicable oMinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations Use TaX : $18.75 made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibility for compliance with the Wheat Ridge Building : $49.75 Code (U.B.C.) and all other applicable heat Ridge ordfi ~nces, for work under this permit. TOt81 (OWNER)(CONTR4CTOR)SIGNED ! ~1J DATE~ Ia.I Description : EVAPORATIVE COOL R Electrical License No : Company: Plumbing License No : Company : Mechanical License No : Company : Expiration Date : Expiration Date : Expiration Date : Approval: Approval: Approval: NE ~mm'a lom (1) This permit was issued in accortlance wifh the provisions set forlh in yopur applica[ion and is subject to ihe laws of the State of Colorado and to the Zonin9 RequlaGOns and Buildiny Code of Wheat Rid9e, Coloratlo or any other applicable ordinances of the Ciry. (2) This permit shall expire if (A) the work auihorized is not commenced within siuly (60) days from issue tlate or (B) the building authorized is suspended or abandoned for a period of 120 days. (3) If this pertnit expires, a new permit may be acquired for a fee of one-half ihe amount normally requiretl, provided no changes have been or will be made in the original plans and specifications and any,suspension or abandonment has not exceeded one (1) year. If chan9es are matle or if suspension or abandonment exceetls one (7) year, Tull fees shall be paid for a new permit (4) No work of any manner shall be done that will change the natural flow of water causin9 a dreinage problem. (5) Contredor shall notify the Builtling Inspector hventy-four (24) hours in advance for all inspec[ions and shall receive written approval on inspec[ion carU before proceediing with successive phases of the job. (6) The issuance of a permit or the approval of tlrawings and specifications shall not be consVued to be a permit For, nor an approval of, any violation of the provisions of the builQ,ing codes oF3ny other prtlinan5e, law,-rule or regulafion. Building Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION zm DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT NO. 234.5933 P.O. BOX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. JOB ADDRESS 40t2& U) J -I- Li_. OWNER ~igJ(// F CONTRACTOR cjk#ls to Linc N /N L~/O 1 ADDRESS ~0.~0 GU/ ~f 5 P~- ADDRESS 14 PHONE 113/-Z;- ZIPCODE CITY h PHONE _Z12 ZIP CODE LICENSE NO. _Z2J ILA- CONTRACT PRICE $ DATE 5- 1. TYPE Ground❑ Woll❑ Proiecting❑ Other Sor D Face 2. MATERIAL Total Square Feet SIGNS 3. ILLUMINATION yes(] No❑ Type Elect. Permit No. 4. SET BACK FROM PROPERTY LINE N (Specify which is front) _ ❑ S_ E ❑ _ W ❑ ❑ Zone_ Approved, Zone Inspector Disapproved 1. TYPE Solid❑ More Than 80% Open❑ Less Than 80% Open MATERIAL Height FENCES 3. SET BACK FROM PROPERTY LINE N (Specify which is front) _ ❑ E ❑ _ W ❑ ❑ Zone_ ADDFOVed,Zone Inspector Disapproved I . 2 OTHER . 3. DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTHER STRUCTURE, GIVING DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) SPECIFY NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TO- ADJOINING HOUSES, STREETS, AND PROPERTY LINES;ON IRREGULAR LOTS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMITTO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE LICENSE NO. PLUMBING PERMIT STATE LICENSE NO. MECHANICAL PERMIT ALUMINUM WIRE UNDER SIZE 8 ILLEGAL FLOOR BSM IST 2ND 3RD 4TH NO. FUEL+CIrcls One Gas011Propone Cod Else Solor N0, WATER CLOSET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER BTU NEW SERVICE - AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK - OTHER _ - -Zy2C F- -HEATING GARBAGE DISP REFRIGERATION SYSTEM POWER SUB-CIRCUITS WATER HEATER Refrigerant Group UTILITY (RANGE, DISPOSER, ETC) AUTO. WASHER Pounds Charge FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS B CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL - TRANSFORMERS B RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS 6/i I hereby acknowledge that this opplica- tion is correct and understand that I cannot start this project until this appli- actlon U approved, I shall comply with the lows of the State of Colorado and to the Zoning Regulations and Building Code of the City of Wheat Ridge. Any vlolotlon f t is above terms will cause immedi a re ocation of this permit PERMIT FEE USE TAX TOTAL FEE '-3 /.dt~ /LIF ~'S__ $ Y' ~ , APPROVED DISAPPROVED CHIEF BUILDING INSPECTOR,Cityof Wheat Ridge CALL 2345933 24 HOURS IN ADVANCE FOR INSPECTIONS DEPARTMENT OF COMMUNITY DEVELOPMENT 7500 WEST 29th AVENUE BUILDING INSPECTION DIVISION PERMIT NO.MM92#4027 237-6944 EXT. 255 P.O. BOX 638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND RECEIPTED BELOW. JOB ADDRESS CONTRACTOR ADDRESS -Z CITY PHONE SIGNS FENCES OWNER ZIP CODE .01-LL3(-) LICENSE NO. OTHER 2' 3. DRAW SKETCH OR SHOW BELOW, THE FENCE, SIGN, OR OTHER STRUCTURE, GIVING DISTANCES FROM PROPERTY LINES. (SETBACKS OR PROJECTIONS INCLUDED) SPECIFY NORTH STREET NAME SHOW DISTANCES FROM THE MAIN BUILDING TO-ADJOINING HOUSES, STREETS, AND PROPERTY LINES;ON IRREGULAR LOTS, SHOW LEAST DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DISTANCE. APPLICATION FOR PLUMBING; ELECTRICAL; MECHANICAL PERMIT THIS APPLICATION WILL BECOME A PERMIT TO PERFORM THE INDICATED WORK ONLY UPON VALIDATION BY THE BUILDING INSPECTION DIVISION. PERMIT WILL EXPIRE 60 DAYS FROM DATE OF ISSUANCE IF WORK IS NOT STARTED WITHIN THAT TIME. ELECTRICAL PERMIT STATE LICENSE NO. ALUMINUM WIRE UNDER SIZE 8 ILLEGAL PLUMBING PERMIT STATE LICENSE NO. FLOOR BSM IST 2ND 3RD 4TH MECHANICAL PERMIT NO FVEL:CirdeOne Gap Oll Propane Cod Elec Solar NO. WATER CLOSET FORCED AIR - BTU TEMPORARY METER WASH BOWL HOT WATER - BTU NEW SERVICE AMPS BATH TUB STEAM - BTU CHANGE SERVICE-AMPS SHOWER AIR CONDITIONING-BTU LIGHTING SINK OTHER HEATING GARBAGE DISP. REFRIGERATION SYSTEM POWER SUB-CIRCUITS WATER HEATER Refrigerant Group UTILITY (RANGE, DISPOSER, ETC.) AUTO. WASHER Pounds Charge FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTORS B CONTROLS FLOOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS B RECTFIERS SEWERS ADDITION TO OLD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES REMARKS 1 hereby acknowledge that this applica- tion is correct and understand that I cannot start this project until this appli- cation is approved. I shall comply with the lows of the State of Colorado and to the Zoning Regulations and Building Code of the City of Wheat Ridge. Any violation of the above terms will cause immediate revocation of-this permit. PERMIT FEE USE TAX TOTAL FEE APPROVE[ 1. TYPE Ground❑ W0110 Proiecting❑ Other Sor D Face 2. MATERIAL Total Square Feet 3. ILLUMINATION Yes❑ No❑ Type Elect. Permit No. 4. SET BACK FROM PROPERTY LINE N _ S_ E _ W Zone_ Approved, Zone Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved 1. TYPE Soltd❑ More Than 80% Open❑ Lees Than 80% Open MATERIAL Height 3. SET BACK FROM PROPERTY LINE N _ S_ E _ W Zone_ Approved,Zons Inspector (Specify which is front) ❑ ❑ ❑ ❑ Disapproved CHIEF BUILDI INSPECTOR,City ZIP CODE 17r v 14 -CJ J" heat Ridge Date Issued / 6 -a 112 5 a PHONE o/ I J CONTRACT PRICE $ )T VALID UNLESS RECEIPTED f-ff '~-/a 7 9' l ~/97~7 5m- CALL 237-6944 EXT. 255 24 HOURS IN ADVANCE FOR INSPECTIONS oo<ent. slon 1