Loading...
HomeMy WebLinkAbout6690 W. 45th Place1* � � i City of Wheat Ridge �� E -Res. Sewer/Waterline Repair PERMIT - 202101570 PERMIT NO: 202101570 ISSUED: 07/21/2021 JOB ADDRESS: 6690 W 45th Pl EXPIRES: 07/21/2022 JOB DESCRIPTION: Repair 15 ft of sewer line in backyard *** CONTACTS *** OWNER (303)456-5822 DONEY BEN C SUB (720)296-7972 TREVOR HARVEY 130129 AFFORD A ROOTER *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 31000.00 FEES Total Valuation 0.00 Use Tax 63.00 Permit Fee 93.35 ** TOTAL ** 156.35 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge E -Res. Sewer/Waterline Repair PERMIT - 202101570 202101570 6690 W 45th Pl ISSUED: 07/21/2021 EXPIRES: 07/21/2022 Repair 15 ft of sewer line in backyard I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any pplicab e code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 07/21/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Sewer or Water Line Repair Permit Application Date: Tuesday, July 20, 20212:35: 10 PM Sewer or Water Line Repair Permit Application This application is exclusively for SEWER OR WATER LINE REPAIR - IN YARD Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Right of Way permits must be applied for with the Public Works Department. Is this application for Yes sewer line or water line repair - in yard only? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 6690 W 45th PI Property Owner Name Toney coney Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Field not completed. Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business Afford -A -Rooter Name Contractor's License 130129 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-296-7972 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email affordarooter99@gmail.com Address Retype Contractor affordarooter99@gmail.com Email Address DESCRIPTION OF WORK Is this a sewer line or sewer Line water line repair? Length of repair 15 feet Location of repair Backyard (backyard, frontyard, etc) Provide additional na details including installation of clean- o uts. Project Value (contract 3000 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Robin Fulton Permit Email not displaying correctly? View it in your browser. PERMIT:2U� ��%- ADDRESS: 1 INSPECTION RECORD JOB CODE: Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground lo _ i 'r o Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof lo _ i 'r o 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS GG9r t�`SPL Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning Inspections from these entities shall be requested one week in advance. For landscaping and parking inspections please call 303-235-2846 For ROW and drainage inspections please call 303-235-2861 For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works 413 Flood plain Inspection 414 Fire Insp. / Fire Protection 415 Public Works Final 416 Storm Water Mgmt. 417 Zoning Final Inspection 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. City of Wheat Ridge Residential Roofing PERMIT - 201707828 PERMIT NO: 201707828 ISSUED: 09/28/2017 JOB ADDRESS: 6690 W 45th PL EXPIRES: 09/28/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 22.33 sq Pitch = 5/12 *** CONTACTS *** OWNER (303)456-5822 DONEY BEN C SUB (303)452-8710 Jim Black 020245 Jim Black Construction, Inc SUB (30,3)870-8613 Jason Savage 080245 Savage Construction *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,302.44 FEES Total Valuation 0.00 Use Tax 384.35 " Permit Fee 346.95 ** TOTAL ** 731.30 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) rpof covering" is required to be on site at the time of final inspection. Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. City of Wheat Ridge ' Residential Roofing PERMIT - 201707828 PERMIT NO: 201707828 ISSUED: 09/28/2017 JOB ADDRESS: 6690 W 45th PL EXPIRES: 09/28/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 22.33 sq Pitch = 5/12 I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications. applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed a4thll work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signatur of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable'code or any ordinanceor regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Dane Lovett From: no-reply@ci.wheatridge.co.us Sent: Tuesday, September 26, 2017 3:13 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Follow Up Flag: Follow up Flag Status: Completed Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) n 6690 W 45th PI Wheat Ridge, CO 80033 Ben Doney 3034565822 189 Property Owner Email Address Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract thedoneys31 @msn.com Yes Signed Contract.pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Jim Black Construction (;20245 3034528710 Contractor Address 12279 Pennsylvania St Thornton, CO 80241 (Primary address of your business) Contractor Email Address aaragon@jimblackconstruction.com Retype Contractor Email aaragon@jimblackconstruction.com Address DESCRIPTION OF WORK TOTAL SQUARES of 22.33 the entire scope of work: Project Value (contract 18302.44 value or cost of ALL materials and labor) Are you re -decking the No roof? Is the permit for a flat Pitched roof (2:12 pitch or greater) roof, pitched roof, or 190 both? (check all that apply) What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 5 22.33 Asphalt Shingles Asphalt For house and shed, Sub contractor Savage Construction Inc. - 3038708613 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. 1 understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to 191 submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Adam Johnston Email not displaying correctly? View it in your browser. 192 PROPOSAL 12279 f 21id'i iYti.ikt 7d6i4 1 tIV s.. f r V,'...a- GE-NrR-41<CON Yw[SCTO W4 1CST03 tX10;N S.—ZC.2I! IS PROPOSAL SUBW11 it ED TO: Ben and Tonya Doney (Owner) ADDRESS: 6630 W 45th Place, Wheat Ridge, CO 80033-3710 JOB LOCATION: 6-6,00 W 45th Placa, Wheat Ridge, CO 80033-3710 – --- PHONE: (303) 456-5822 DATE: July 19, �: < _. __-. .z „:.: r',.:.r_7� i ._s-:. .. .. _ .__ :�,. .-... .... _.. ,'"•iw i. _ -. _. ... .,. -a. _ ��e.. d i" •.f a u . _ - s ax, s s _ ° -1 s, ly',_• f.�.- s.. h— Sc .,_ . cF Xork"}: A� a ....y tt71(]it5}7lete Any additional hai' r?lated ria_ no-rgE iS the- F€: ��r"i 2T?r.xdCy 4or ir. a.6 . v r:,as, r S I�Ci � ��:d:tcs :.� 4' _} Fdi >.i` t'� _ � a Wyrp P •^' G'E to rt,. - ... ! , dam.- e J Sc y t .�s. � h atE� '.���AyT��4y�4i l�i.C•[raT� iV �4t�E�r t"j�if Vias}""4Li36s. £i`�t1 d:.:^yi J� 1 Ct�.r:�.. °w[�ifvli 1Y&ilk EYeV v�.hi�'L �Y 4n�V�, SVr the sum of. As per final adlusted amount from Nat=ionwide Mutual insurance Company settlement Dollars $ Llhe"Contract Price") --- — --- – ---- --- ----- This Proposal is provided to Owner/Insured subject to the terms and conditions printed on the opposite side of this Proposal (the "Terrns arasR cro5tt t€r+ns"i Contractor Signature Note: This Proposal may be withdrawn by us if not accepted within 30 days. ACCEPTANCE OF The GvinedIa ored hereby Signature accepts this Proposal: Date of Acceptance Signature V Jim Black Construction 12It279 Pennsylvania St. Thornton, CO 80241 �f 303-452-8710 TIN - 84-1139625 Insured: BEN DONEY Property: 6690 W 45TH PL WHEAT RIDGE, CO 80033-3710 Home: 6690 W 45TH PL WHEAT RIDGE, CO 80033-3710 Claim Rep.: Allen Marquet Business: P.O. Box 182712, 3400 Southpark Place,Suite A DSPF-62 Grove City, OH 43123-4856 Estimator: Adam Johnston Company: Jim Black Construction Business: 12279 Pennsylvania St Thornton, CO 80241 Reference: Company: Nationwide Contractor: Company: Jim Black Construction Claim Number: 169539 -GF Date Contacted: 5/17/2017 9:27 AM Date of Loss: 5/8/2017 12:00 AM Date Inspected: 5/24/2017 9:00 AM Date Est. Completed: 5/26/2017 4:54 PM Policy Number: HON 0016883746 Price List: CODE8X MAY17 Restoration/Service/Remodel Estimate: BEN DONEY Home: (303) 456-5822 Business: (303) 289-4831 E-mail: thedoneys3l@msn.com Business: (855) 311-1048 x 138 Fax: (855)865-6590 Cellular: (610) 986-8777 E-mail: marquea@nationwide.com Business: (303) 552-6336 E-mail: ajohnston@jimblackconstruct ion.com Business: (303) 452-8710 Type of Loss: Hail Date Received: 5/9/2017 12:00 AM Date Entered: 5/12/2017 4:30 PM NIJ Jim Black Construction 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN - 84-1139625 Dear Valued Customer, Please refer to the enclosed itemized estimate. This estimate contains the valuation of the damages for this reported loss which we prepared using reasonable and customary prices for your geographic area. If any hidden, or additional damage, and/or damaged items are discovered, we will contact your Claims Representative immediately. Coverage for the hidden or additional damages and/or damaged items, will need to be determined by the Claims Representative and may require an inspection/re-inspection before any supplemental payment or repairs are authorized. Please do not destroy or discard any hidden, or additional damages, and/or damaged items until the Claims Representative is notified and provided an opportunity to review the hidden or additional damages and/or damaged items, and reached an agreement with you on any supplemental costs. Payments for the On Your Side Property Repair Network are not made until the work has been completed and you have signed a "Certificate of Satisfaction & Authorization to Pay" form. We will not ask you to, nor should you, sign the form until you are truly satisfied with the completed work. It is possible that your mortgage company will be included on the payment for repairs. If this occurs, please contact the mortgage company to discuss how to handle the proceeds of the payment. Please contact your Claims Representative at the number listed above if you have any questions regarding any matters pertaining to your claim. Thank you. It is unlawful to knowingly provide false, incomplete, or misleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the company. Penalties may include imprisonment, fines, denial of insurance, and civil damages. Any insurance company or agent of an insurance company who knowingly provides false, incomplete, or misleading faces or information to a policyholder or claimant for the purposes of defrauding or attempting to defraud the policyholder of claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado division of insurance within the department of regulatory agencies. BEN_DONEY 9/29/2017 Page:2 Jim Black Construction 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN -84-1139625 BEN_DONEY House House DESCRIPTION QTY UNIT PRICE TOTAL 1. Haul debris - per pickup truck load - including dump fees 1.00 EA @ 131.74 = 131.74 Debris removal for all non roof materials. Roof debris included in tear off. Roofl DESCRIPTION QTY UNIT PRICE TOTAL 2. Digital satellite system - Detach & reset 1.00 EA @ 36.26 = 36.26 3. Remove Tear off, haul and dispose of comp. shingles - 3 tab 17.43 SQ @ 49.03 = 854.59 4. Remove Add. layer of comp. shingles, remove & disp. - 3 tab 34.87 SQ @ 31.38 = 1,094.22 Note: There are 3 total layers 5. Drip edge 187.86 LF @ 1.98 = 371.96 This item replaces RFGFELT15 Roofing felt - 15 lb. or expands the scope of repairs, as required by current building codes Settlement is based on the associated item until the code upgrade cost is incurred, subject to limits. 7. Roofing felt - 15 lb. 7.07 SQ @ 27.99 = 197.89 8. Roofing felt - 15 lb. 10.36 SQ @ 27.99 = 289.98 9. 3 tab - 25 yr. - comp. shingle roofing - w/out felt 20.33 SQ @ 184.84 = 3,757.80 Includes an allowance for hip and ridge caps 10. Flashing - pipe jack - split boot 1.00 EA @ 63.09 = 63.09 11. Roof vent - turbine type 1.00 EA @ 99.50 = 99.50 12. Flashing -pipe jack 2.00 EA @ 34.13 = 68.26 13. Roofer -per hour 2.00 HR @ 115.02 = 230.04 Labor to work around undamaged exhaust vents 14. Roof vent - turtle type - Metal 1.00 EA @ 50.17 = 50.17 15. Exhaust cap - through roof - 6" to 8" 2.00 EA @ 73.89 = 147.78 Note: Caps have been damaged by hail see photos as reference 16. Exhaust cap - through roof - up to 4" 1.00 EA @ 67.64 = 67.64 Note: Caps have been damaged by hail see photos as reference Front Elevation DESCRIPTION 17. R&R Window screen, 1 - 9 SF 18. R&R Exterior post light fixture BEN_DONEY QTY UNIT PRICE TOTAL 1.00 EA @ 40.40 = 40.40 1.00 EA @ 214.96 = 214.96 9/29/2017 Page:3 Jim Black Construction 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN - 84-1139625 CONTINUED - Front Elevation DESCRIPTION QTY UNIT PRICE TOTAL 19. R&R Vinyl outside corner post 15.33 LF @ 6.15 = 94.28 Note: Hail hit 2 corners on front elevation see photos. 223.17 SF @ 1.07 = 238.80 20. Paint corner trim - one coat 15.33 LF @ 0.72 = 11.04 Note: Corner is currently painted and will need to be painted 2.00 EA @ 40.40 = 80.80 21. R&R Vinyl J trim 4.00 LF @ 3.90 = 15.60 22. Paint trim - one coat 4.00 LF @ 0.72 = 2.88 Note: trim is currently painted and will need to be painted 16.00 LF @ 0.72 = 11.52 Right Elevation Height: 4" DESCRIPTION QTY UNIT PRICE TOTAL 23. R&R Siding -vinyl 223.17 SF @ 3.91 = 872.59 24. R&R Rigid foam insulation board - 1/2" 223.17 SF @ 1.07 = 238.80 25. Seal & paint wood window (per side) 2.00 EA @ 41.53 = 83.06 26. R&R Window screen, 1 - 9 SF 2.00 EA @ 40.40 = 80.80 27. Paint trim - one coat 24.33 LF @ 0.72 = 17.52 Note: Trim is currently painted and will need to be painted QTY UNIT PRICE TOTAL 28. Paint corner trim - one coat 16.00 LF @ 0.72 = 11.52 Note: Comer is currently painted and will need to be painted Back Left Elevation Height: 4" DESCRIPTION QTY UNIT PRICE TOTAL 29. R&R Siding -vinyl 118.46 SF @ 3.91 = 463.18 30. R&R Rigid foam insulation board - 1/2" 118.46 SF @ 1.07 = 126.75 31. Paint door or window opening - 2 coats (per side) 1.00 EA @ 23.45 = 23.45 Gutters and Misc DESCRIPTION QTY UNIT PRICE TOTAL BEN DONEY 9/29/2017 Page: 4 Jim Black Construction 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN - 84-1139625 CONTINUED - Gutters and Misc DESCRIPTION QTY UNIT PRICE TOTAL 32. R&R Gutter / downspout - aluminum - up to 5" 217.17 LF @ 5.79 = 1,257.41 Gutters and downspouts Left Elevation Height: 4" DESCRIPTION QTY UNIT PRICE TOTAL 33. R&R Siding -vinyl 227.49 SF @ 3.91 = 889.48 34. R&R Rigid foam insulation board - 1/2" 227.49 SF @ 1.07 = 243.41 Shed Roofl DESCRIPTION QTY UNIT PRICE TOTAL 35. Remove Tear off, haul and dispose of comp. shingles - 3 tab 1.96 SQ @ 49.03 = 96.10 36. Drip edge 56.61 LF @ 1.98 = 112.09 37. Roofing felt - 15 lb. 1.96 SQ @ 27.99 = 54.86 38. 3 tab - 25 yr. - comp. shingle roofing - w/out felt 2.00 SQ @ 184.84 = 369.68 39. Material Only Sheathing - OSB - 1/2" 196.00 SF @ 0.48 = 94.08 40. Carpenter - General Framer - per hour 10.00 HR @ 58.04 = 580.40 Note: sheathing will need to be replace due to weathering. As the roof sits currently it is unsafe to place anyone on it. Shed Exterior Door DESCRIPTION Height: Peaked 4'X 6181# Opens into Exterior QTY UNIT PRICE TOTAL 41. R&R Sheathing - plywood - 1/2" CDX 32.00 SF @ 1.88 = 60.16 Replace damaged sheathing above door 42. Exterior - paint two coats 407.28 SF @ 0.87 = 354.33 BEN_DONEY 9/29/2017 Page:5 I Jim Black Construction (�W, 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN - 84-1139625 Labor Minimums Applied DESCRIPTION QTY UNIT PRICE TOTAL 43. Electrical labor minimum 1.00 EA @ 103.23 = 103.23 Grand Total Areas: 474.89 SF Walls 717.15 SF Floor 0.00 SF Long Wall 717.15 Floor Area 1,003.47 Exterior Wall Area 1,939.15 Surface Area 20.42 Total Ridge Length Coverage Dwelling Dwelling - Code Upgrade Other Structures Contents Total 797.55 SF Ceiling 79.68 SY Flooring 0.00 SF Short Wall 733.81 Total Area 254.17 Exterior Perimeter of 1,130.37 Walls 19.39 Number of Squares 101.97 Total Hip Length Item Total 1,272.44 SF Walls and Ceiling 247.50 LF Floor Perimeter 254.30 LF Ceil. Perimeter 474.89 Interior Wall Area 187.86 Total Perimeter Length % ACV Total % 12,925.76 92.51% 14,911.80 92.95% 0.00 0.00% 0.00 0.00% 1,047.22 7.49% 1,130.37 7.05% 0.00 0.00% 0.00 0.00% 13,972.98 100.00% 16,042.17 100.00% BEN DONEY 9/29/2017 . Page: 6 Jim Black Construction 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN - 84-1139625 Summary for Dwelling Line Item Total 12,925.76 Overhead 1,292.59 Profit 1,292.59 Material Sales Tax 326.05 Replacement Cost Value $15,836.99 Less Depreciation (925.19) Actual Cash Value $14,911.80 Less Deductible (1,000.00) Net Claim $13,911.80 Total Recoverable Depreciation 925.19 Net Claim if Depreciation is Recovered $14,836.99 Adam Johnston BEN_DONEY 9/29/2017 Page:7 Jim Black Construction (AZjj" 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN - 84-1139625 Summary for Dwelling - Code Upgrade Line Item Total 0.00 Replacement Cost Value $0.00 Net Claim $0.00 Dwelling - Code Upgrade Paid When Incurred Line Item Total 969.07 Overhead 96.91 Profit 96.91 Material Sales Tax 17.73 Replacement Cost Value $1,180.62 Total Paid When Incurred $1,180.62 Dwelling - Additional Coverage Limit Recap Description Single Item Limit Aggregate Limit RCV Overage Dwelling - Code Upgrade $18,510.00 $18,510.00 $1,180.62 $0.00 $1,180.62 $0.00 Adam Johnston BEN DONEY 9/29/2017 Page: 8 I � Jim Black Construction 12279 Pennsylvania St. Thornton, CO 80241 303-452-8710 TIN -84-1139625 Line Item Total Overhead Profit Material Sales Tax Replacement Cost Value Less Depreciation Actual Cash Value Net Claim Total Recoverable Depreciation Net Claim if Depreciation is Recovered Summary for Other Structures Adam Johnston 1,047.22 104.73 104.73 28.15 $1,284.83 (154.46) $1,130.37 $1,130.37 154.46 $1,284.83 BEN_DONEY 9/29/2017 Page:9 /O i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: (-/ 8 9- r r. a/ Job Address: (o (0 4 0 w (-/ s— i� 1 Permit Number: �D o I -70 7 S -a Q ( ❑ No one available for inspection: Time T = a$ QM/PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303 -234 - Date: 11 i /-7 Inspector: _Q> DO NOT REMOVE THIS NOTICE i CITY OF WHET RIDGE~ _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ! (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 C /o - "6.1"! Job Address: 1, 6 9 0 1,� -1 S `-4 its- I Permit Number: 20 1 -7 0 -7 8 a Fs i1t G� o v r�' pp 00VleC{ ❑ No one available for inspection: Time 11='IS-S7- 90M Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: / // /-7 Inspector: 7_6 DO NOT REMOVE THIS NOTICE i CITY OF WHET RIDGE~ _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office ! (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 C /o - "6.1"! Job Address: 1, 6 9 0 1,� -1 S `-4 its- I Permit Number: 20 1 -7 0 -7 8 a Fs i1t G� o v r�' pp 00VleC{ ❑ No one available for inspection: Time 11='IS-S7- 90M Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: / // /-7 Inspector: 7_6 DO NOT REMOVE THIS NOTICE DEPARTMENT OF COMMUNITY DEVELOPMENT 7500WEST29thAVENUE BUILDING INSPECTION DIVISION PERMIT NO.M93#18910 234-5933 P.O. BOX638 CITY OF WHEAT RIDGE, COLO. THIS PERMIT VALID ONLY WHEN SIGNED BY TFiE CHIE.F BUILDING INSPECTOR AND RECEIPTED 8EL7W /n A PLICATION FOR MISCELLANEOU~~~p; ~ERMIT JOB ADDRESS (Cl OWNER ~I k en-C Q CONTRACTOR ADDRE55 '7:)C~m Sl _ ADDRESS l -10~ - PHONE ZIPCODE 003 CITY 2 ~ ZIP CODE CONTRACT PRICE PHONE 42~ OO LICENSE NO. DATE g' 7 -(73 I. TYPE Ground❑ Woll❑ Proieetinq❑ Othsr SaDFOae , 2. MATERIAL To4al Squara Faat SIGNS 3. ILLUMINATION Yea❑ No❑ 7ype Eleef. Parmit No. 4. SET BACK FROM PROPERTY IINE N_ 5_ E_ 1Y ` Zone_ Apprwed,Zona Inapsetor 1. TYPE SolidLJ Moro Than BO% OpenU lass Thon 80% Open FENCES MATERIAL Hsiphf 3. SET BACK FROM PROPERTY LINE N_ S_ E_ W Zone_ Apprwed,Zons Inspsota (Specity whitA ie tront) ❑ ❑ Q ❑ DisnDDroved I. OTHER 2 -7"a R DRAW SKETCH OR SHOW BELOW, THE FENCE,SIGN,OR OTHER SYRUCTURE,GI\(SETBACKS OR PROJECTIONS INCLUDED) PERMIT FEE CC) JOB ADDRESS DATE: ll '(6 BLDG. PERMIT# 8qIb PERMIT# BLDG. CONTR STREET NAME SUBCONTRACTOR SHOW DISTANCES FROM 7HE MAIN BUILDING T6ADJOINWG HOUSES,STREETS,AI DATE INSP. REQ. ~J6 DISTANCE TO PROPERTY LINES, NOT MAXIMUM OR AVERAGE DI$TAN(:E. APPLICATION FOR PLUMBIfVG; ELECTRICA' TYPE OF INSP. THIS APPLICATION WILL BECOMEA PERMITTO PERFORM THE INDICATED WORK i l' /;3 PERMIT WILL EXPIRE 180 DAYS FROM THE DATE OF ISSUANCE INSPECTION MADE ~~lI V lY ELECTRICAL PERMIT STATE LICENSE N0. PLUMBIN6 PERMI REMARKS STATE IICENSE N0. ALUMINUM WIRE UNDERSIZE 81LLEGAL FLOOR BSM I5T 21 P10. WATER CIASET TEMPORARY METER _ WASH BOWL NEW SERVICE AMPS BATH TUB FORM 6-19 W R CHANGE SERVICE-AMPS SHOWER . . LIGHTING SINK / / HEATING GARBAGE DISP ~ POWER SUB-CIFCUITS WATER HEATER UTIUTY(RANGE,DISPOSER,ETC.) AUTO.WASHER FIXTURES DISH WASHER AUTOMATIC SPRINKLER SYSTEM WIRING MOTOF2S 9 CONTROIS FLfJOR DRAIN ELEVATOR SIGNS URINAL TRANSFORMERS 9 RELTFIERS SEWERS ADDITION TO OlD WORK OTHER MOTORS OVER I HP TOTAL FIXTURES I hareby acknowledqe that this applica- fion ia torreet and undersfand that I Connof sfarf this projett until ihis appli- cotion ia apDroved. I shall comply wifh ths lawa of Ihe Stote of Colorado and fo }hs Zoninq Repulntions and Buildinp Code of the City a! Wheat RidQe. Any violation of the above terme will cause immediate revocotion ot fhis permit ~ . „ ,71 4DOlicann 4iBn^lure USE TAX INSPECTION tICKET - ~ (/-V TOTAL FEE $ 0--ell APPROVED DISAPPROVED 44 CHIEF BUILDI INSPECTOR,City of Wheat Ridqe Date Issued~~'- NOT VALID UNLESS RECE ~a~s3 CALL 234-5933 24 HOURS IN ADVANCE FOR INSPECTIONS