Loading...
HomeMy WebLinkAbout7105 W 29th Placei CITY OF WHEAT RIDGE - Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. uslinspection Date: Inspector: DO NOT REMOVE THIS NOTICE 1* � � i City of Wheat Ridge �� E -Res. Sewer/Waterline Repair PERMIT - 202002332 PERMIT NO: 202002332 ISSUED: 11/12/2020 JOB ADDRESS: 7105 W 29th Pl EXPIRES: 11/12/2021 JOB DESCRIPTION: Sewer repair in front yard 30 feet, adding clean outs. *** CONTACTS *** OWNER (720)252-5522 TAVANO CHRISTOPHER P SUB (303)766-7500 ROBERT LOGAN 021818 PLUMBLINE SERVICES LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 41500.00 FEES Total Valuation 0.00 Use Tax 94.50 Permit Fee 125.05 ** TOTAL ** 219.55 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** Both the front and back of this permit are required to be posted on the job site at all times. If the complete permit is not present, inspections WILL NOT be performed. 1* � � i City of Wheat Ridge �� E -Res. Sewer/Waterline Repair PERMIT - 202002332 PERMIT NO: 202002332 ISSUED: 11/12/2020 JOB ADDRESS: 7105 W 29th Pl EXPIRES: 11/12/2021 JOB DESCRIPTION: Sewer repair in front yard 30 feet, adding clean outs. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Sewer or Water Line Repair Permit Application Date: Wednesday, November 11, 2020 7:55:21 AM Sewer or Water Line Repair Permit Application This application is exclusively for SEWER OR WATER LINE REPAIR - IN YARD Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Right of Way permits must be applied for with the Public Works Department. Is this application for Yes sewer line or water line repair - in yard only? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 7105 W. 29th PI Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Carly Tavanno r`18DPWzi%W Property Owner Email permits@plumblineservices.com Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business Plumbline Services Name Contractor's License 021818 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 3034348764 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email permits@plumblineservices.com Address Retype Contractor permits@plumblineservices.com Email Address DESCRIPTION OF WORK Is this a sewer line or Sewer Line water line repair? Length of repair 30' Location of repair Front (backyard, frontyard, etc) Provide additional Sewer repair in yard. Add clean outs. details including installation of clean- o uts. Project Value (contract 4500 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Scott cutting Permit Email not displaying correctly? View it in your browser. A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type:�-- Job Address: Vj ¢ - Permit Number: U 1 '71, ❑ No one available for inspection: Time ' AM/PM Re -Inspection required: Yes ;No When corrections have been made, schedule for re -inspection online at: h ttp://www. cL wheatridge. co. ushnspection Date: V c1 * l (' Inspector: DO NOT REMOVE THIS NOTICE o s CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: -'1 1 U `- 1 . (to,- Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: httpYlwww.ci. wheatridge.co, uslinspection Date:_'!) , Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Homeowner Basement Finish PERMIT - 201802433 PERMIT NO: 201802433 ISSUED: 09/10/2018 JOB ADDRESS: 7105 W 29th P1 EXPIRES: 12/09/2019 JOB DESCRIPTION: Install 1 egress window, vertical cuts only; add bedroom, bathroom and family room; move vent for hvac & water heater; electrical and plumbing; 900 sq ft total *** CONTACTS *** OWNER (720)227-1612 TAVANO CHRISTOPHER P SUB (303)419-0417 Jose Garcia 180225 Garcia Pluming LLC SUB (720)261-9491 Adam King 150050 A.R. King Air SUB (303)202-9836 Frank Anthony Jaime 130166 T.E.S. LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 31,750.00 FEES Total Valuation 0.00 Plan Review Fee 339.66 Use Tax 666.75 Permit Fee 522.55 Extend Expired Permi 120.00 ** TOTAL ** 1,648.96 *** COMMENTS *** *** CONDITIONS *** Homeowner performing all work without the assistance of subcontractors. All roughs to be done at Framing Inspection. I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. Consultations and inspections will only be performed with the homeowner of record present. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. City of Wheat Ridge Homeowner Basement Finish PERMIT - 201802433 PERMIT NO: 201802433 ISSUED: 09/10/2018 JOB ADDRESS: 7105 W 29th P1 EXPIRES: 12/09/2019 JOB DESCRIPTION: Install 1 egress window, vertical cuts only; add bedroom, bathroom and family room; move vent for hvac & water heater; electrical and plumbing; 900 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal ner of property and am authorized to obtain this permit and perform the work described and approved in conjunction with this'pern . I f rther test that I horized to include all entities named within this document as parties to the work to be perfor d an tha a 1 work to)Vee per ormed - is �n this document and/or Cits' accompanying approved plans and specifications. Signa re oP46NER or ONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6, The issuance or granting of a permit sh `11,,not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or a y rine or re tion of this jurisdiction. Approval of work is subject to field inspection. { Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wh6atpllg "" m ENT City of Wheat Ridge Municipal Building 7500 W. 291' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Permit Extension Request Form Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days may be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. Please complete this form in its entirety and submit to the Building Division at permits amci.wheatrid eg co.us or fax to 303-237-8929. Party requesting permit extension s PAZ p 0J Permit # L.0 i33 Property Address: 41 O 1,0, Z�� '�t_t► C Phone # 12-0 X7i%- l (p12, Email Address: G ���/ C" rvo Yvt.vl`, I . c -o Reason for extension request: r "i.' -Z 'T- lk-IC- 4;(2 2nLI s fji f�:�'7� Lt~'I byf i L+� �� %�1 JAZ _ ALt- ! f6ti; 15 L�1 i� IS A 4,JAh)1LA1 L Number of days requested �j c� Printed Name: G ets 1AVA4y Signature: Date: 2 / For office use only This request has been Approved by: J)e2o CXT �,_ AJs(O fJ pproved I Denied Extended until: C fvw w .ci.w heatridge.co.us Date: to i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 4 -,;?) LFT_ Job Address: �� iii �.A , �4 I Permit Number:, -y,' ❑ No one available for inspection: Timd--"' AM/PM Re -Inspection required: Yes No When corrections have been made, caLr nspection at 303-234-5933 ti { Date: Inspect. DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: £ � ' Y - i v w Job Address: Permit Number: �-i A�il�✓U� ! � ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: i j i Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: t-3 Job Address: I �, _1r �1 10 , Permit Number: CA -'P% CJ S^� ❑ No one available for inspection- imef A /PM 00- Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303 -234- Date: - 03 -234 - Date: Inspector: bc_- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: C'^� Job Address: Permit Number: `�k� .0 ❑ No one available for inspection: Time /PM Re -Inspection required: Yes filo �Z") When corrections have been made, call for re -inspection at 303-234-5933 Date: \c Inspector: - DO NOT REMOVE THIS NOTICE Aa CITY OF WHEAT RIDGE _��9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE•J � J Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time 1C� ``' `` AM/PM-) Re -Inspection required: YesNo When corrections have been made, call for re -inspection at 303 -234 - Date: �/ Inspector:J DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:--��^ �-."� 6 Job Address: Permit Number: t�_ L) No one available for inspection: Time AM/PM Re -Inspection required: Yee5;NZ----" When corrections have been made, call for re -inspection at 303-234-5933 Date:` '�nspecto .�--� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: v'—C�vc vnc y -4-)\,) C4 V, PWY. � Job Address: Permit Number: Z)©l% 0 ';) q 3 _i -- C% c) W ❑ No one available for inspection: Time _t6l A�/PM Re -Inspection required: Yes) No When corrections have been made, call for re -inspection at 303-234-5933 Date:—k q -A Inspector: Y� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (403) 234-5933 Inspection line _ (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 317 12, Inspection Type: 313- R ov+� v, 7L, Job Address:5 Permit Number: 'UNZ �3 3 LlNo one available for inspection: Time `',' AM/ M Re -Inspection required: When corrections have been made, call for re -inspection at 303 -234 - Date:. Z 1 / 10 inspector: bels -e L& ft DO NOT REMOVE THIS NOTICE City of Wheat �idge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM *This application must be signed by each sub -contractor confirming the same. Project Address: 'i/ C 60� '— p( � Permit v 3 3 General Contractor: 1 ,b"_eo�„�/� 3 , 'T Electrical Contractor - Wheat Ridge License # f 30) Cc C�—_ Company Name: T�`(-.s . Phone State License #: �''3 1 Master #: Signature of Authorized Agent Date Company Name: Phone #: State License #: Master #: Signature of Authorized Agent Date of Date *This application must be signed by each sub -contractor confirming the same. F i CITY OF WHEAT RIDGE ` Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 31 i— Job �✓`��ov. Job Address: 710 5 L/ 21r Permit Number: '2�3 , ❑ No one available for inspection: Time °'/{�" A/PM Re -Inspection required: Yes IVo When corrections have been made, call for re -inspection at 303-234-5933 Date: /1)5/) Inspector:DA9r1t- LO I, DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE �'(303) Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 21 S_ U0L::fr- pa.,l Job Address: ?. qjh Permit Number: `? dl Jfv 3; .. J1 0 //11 - t't t - ti Jam'- fre irlad ❑ No one available for insppeection: Time ; t? 0 Awpm i = A Re -Inspection required: &Y✓ No When corrections have been made, call for re -inspection at 303 -234 - Date: 11 % ! y /i qj Inspector: bane, L-ov c DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE _. i Inspection Type: �Li i �rl/i►.!i xi? )elo n�o� Job Address: 7%f L4/ Permit Number: 9-01f 0 ❑ No one available for inspection: Ti e AM/PM Re -Inspection required: Yes No When corrections have been made, chflfor re -inspection at 303-234-5933 r Date: [ Inspector:—,,)T/ DO NOT REMOVE THIS NOTICE City of Wh6atP. e COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM This form must be signed by each sub -contractor. This form will not be accepted with missing information. Subcontractor's City of Wheat Ridge License number must be provided in the applicable space. Subcontractor's insurance an licensq u bb up to date prior to permit issuance. Project Address: -7/ 0 � Per it #: General Contractor: (fh�S o b erY Electrical Sub -Contractor Company Name: State License #: Wheat Ridge License #: Phone #: Master #: (required field) Signature of Authorized Agent Date Plumbing Sub -Contractor Company Name:Z ZZ Phone #: '� 7 State License #: 3 Z 2 r Master #: 6 00 l S/ - Wheat Ridge License #: ` Mechanical Contractor Company Name: (required field) (a -3o -,W �g Date Phone: Wheat Ridge License #: (required field) Signature of Authorized Agent Date City of Wheat Ridge y: Homeowner Basement Finish PERMIT - 201802433 PERMIT NO: 201802433 ISSUED: 09/10/2018 JOB ADDRESS: 7105 W 29th P1 EXPIRES: 09/10/2019 JOB DESCRIPTION: Install 1 egress window, vertical cuts only; add bedroom, bathroom and family room; move vent for hvac & water heater; electrical and plumbing; 900 sq ft total *** CONTACTS *** OWNER (720)227-1612 TAVANO CHRISTOPHER P *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 31,750.00 FEES Total Valuation 0.00 Plan Review Fee 339.66 Use Tax 666.75 Permit Fee 522.55 ** TOTAL ** 1,528.96 *** COMMENTS *** *** CONDITIONS *** Homeowner performing all work without the assistance of subcontractors. All roughs to be done at Framing Inspection. I, the property owner, by my signature, attest that I currently reside at the project property, intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers. If professionals are hired, those contractors are licensed with the City of Wheat Ridge and are listed on the permit. Consultations and inspections will only be performed with the homeowner of record present. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. V ! t., City of Wheat Ridge Homeowner Basement Finish PERMIT - 201802433 PERMIT NO: 201802433 ISSUED: 09/10/2018 JOB ADDRESS: 7105 W 29th P1 EXPIRES: 09/10/2019 JOB DESCRIPTION: Install 1 egress window, vertical cuts only; add bedroom, bathroom and family room; move vent for hvac & water heater; electrical and plumbing; 900 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications; applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of e propert and am authorized to obtain this permit and perfonn the work described and approved in conjunction with this permit. rthe ttest th a le all authorized to include all entities named within this document as parties to the work to be performe th 1 r to rme disclosed in this document and/or its' accompanying approved plans and specifications. Signature of WNER or CONTRACTOR (Circle one) Date I . This pe it was issue aced on the information provided in the permit application and accompanying plans and specifications and is subject to lance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, anew permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of amanner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit ho lnyder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit hall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or^ordinance orlpulation of this jurisdiction. Approval of work is subject to f any inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of, W heat'1d e Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: oermit LI,y eatf'idgje_o.us I FOR OFFICE USE ONLY I Date: 9 I _ Plan/Permit # "j An / � V 33 Plan Review Fee: bJ)J, J Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: J�), Z�� �� A)HC tT Property Owner (please print): I S "-TA,1A1 ly Phone: Property Owner Email: C -P-" -itiV VV Tenant (Commercial Projects Only) Property Owner Mailing Address: (if different than property address) Address.- , ddress: , State, Z Architect/Engineer: Architect/Engineer E-mail: Contractor: City of Wheat Ridge License #: Contractor E-mail Address: For Plan Review Questions & Comments (please print): Phone: Phone: CONTACT NAME (please print): �otf iS ���A40 Phone: q2-0- t L,i Z_ CONTACT EMAIL(p/ease print): i:- etLlV4',v"-o tee- l Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑ COMMERCIAL RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. P�� /'lf►)ED J?Enrw 4 (,o t=e�E4T ' U N e r6Istt&-> PPL rT' IIM57-ALL 1 7()o S& P"r' 1 L:A-u It4� (F1_0,T-1l5D ` I � SiIL ATL ark 44 >PLUWler/�� MDye /VC�,-r 4-v AL. I*W Pr` Y"' ALL � �+&4� 1TAPZ Commercial Projects Only: Occupancy Type: Sq. Ft./LF q t C Amps BTUs Squares Construction Type: Gallons Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ 2G , '�;vv OWNERWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate:. that 1 have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application: that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. C/RCLEONE: (OWNER (CONTRACTOR) Lr (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) SiEnature (first and last name): f'!f';; d< DATE:- Printed Name: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Reviewer: BUILDING DEPARTMENT COMMENTS: O/C C' y X �� _ CJ i �v�g t4�Inc,) r/11�S�J G�reSJ Iii' i1dvLv = 3rS'tV, Reviewer. / 31) 75% PUBLIC WORKS COMMENTS: Reviewer. Building Division Valuation: —7 �� City of Wh6atPsjd•e COMMUNITY DEVELOPMENT g Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): Project Property:_ —7 Z: W. Z j'PL Project Type: _`�►''� t 11� S-1 �i c rfst o,� c L Notariz6d-st'goture of Applicant State of Colorado } County of ss The foregoing instrument was acknowledged by me this `7 day of 0 by TAMARA D ODEAN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20164015481 MY COMMISSION EXPIRES APRIL 22, 2020 \ My Commission Expires I/ ZZ/20�� Notary Public 1417 S. PITKIN CT. AURORA, CO 80017 JC OFFICE 303.755.4927 CELL 720.205.8776 Construction & Remodeling Inc. PROPOSAL & CONTRACT 25 years of Quality Craf tsmanship PROPOSAL NO. DATE PROPOSAL SUBMITTED TO: WORK TO BE PERFORMED AT: NAME - - CITY, STATE ADDRESS PHONE NO. r t b ( r { �t -, /.' 6u n : I,{(� "his 3 'l ; t` J I) ' ' All material is guaranteed to be as specified, and the above work to be performed in accordance with the drawings and specifications submitted for above work and completed in a substantial workmanlike manner for the sum of: AMOUNT _c 6. . j'{;, ; r %.i $DOLLARS$ �! C1c� �1 Ya�'�;t , WITH PAYMENTS TO BE AS FOLLOWS Any alteration or deviation from above speci- RESPECTFULLY i fications involving extra costs will be executed SUBMITTED li ; JI? -5 Yr rr ., only upon written order, and will become an t extra charge over and above the estimate. All ✓~� agreements contingent upon strikes, accidents, SIGNATURE- or delays beyond our control. � NOTE —This proposal maybe withdrawn by us if not accepted with days. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as specified. Payments will be made as outlined above. DATE SIGNATURE STARTING DATE SIGNATURE 1 rr City of ��qrWh6atp-j,d g� COMMUNITY DEVELOPMENT PROJECT ADDRESS: '9`-105 UJ, 7—,q4- PL How to Use this Guide Provide two 2 sets of plans and complete the following: 1. Review this Building Guide — Review the requirements set forth in this guide for submittal and compliance with applicable codes. 2. Provide 2 Floor Plans — one existing floor plan, one proposed, two copies of each, minimum 11" x 17" in size, drawn to scale, indicating room sizes and types. Identify furnace, water heater, plumbing fixtures, electrical outlets, lights, smoke and carbon monoxide detectors, and windows, including size and type, and any other pertinent information. 3. Fill out a Building Permit Application. The majority of permit applications are processed in 1 to 2 weeks. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. Reviewed and approved plans and permit must accompany this document on site throughout project J W heat idge> Wheat Ridge Building Department Approved BUILDING OFFICIAL DATE validity of permit_ me issuance of a permit or approval afplans, specifications and computations shall not be a permit for, or an approval of, any violation m any. of the provisions of the building code or of any city ordinances. Permits presuming to give authority to violate or cancel the provisions of the Bulldind codes or other ordinances of the City shall not be valid. This handout is intended to accommodate projects constructed under the 2012 International Residential Code. It is not intended to cover all code requirements or circumstances. Check with the City of Wheat Ridge Community Development Department for additional requirements. htto //www.ci.wheatridge.co.us Sample Floor Plan i -44N it Edo ac F'A;vt l t_y `tC a a M -L--- 6 I UNFIN L51iE STORaG� M 17,-0` R I C' =ao€i 1 + �-. FdN 6rI • $e.'o Reorn - i 1 PROJECT ADDRESS: *7 © 5 ✓ .. `l �'L. FLOOR PLAN REQUIREMENTS: 1. Submit two (2) complete sets of required information, including plans and equipment specifications. 2. Provide two (2) copies of floor plans, drawn to scale, a minimum of I1" x 17", with room dimensions and use indicated. For basements that are currently partially finished, provide two (2) copies each of floor plan showing current condition and proposed new or altered condition. 3. Plans must show the layout and type of electrical outlets, lighting, smoke alarms and carbon monoxide detectors. Smoke alarms are required to be hard -wired and interconnected in new and existing bedrooms, halls and each level of the house unless removal of interior wall or ceiling coverings would be required. If removal of interior wall or ceiling coverings would be required, battery operated devices may be substituted. Carbon monoxide detectors may be hard -wired or battery powered and are required to be installed within fifteen (15) feet of each bedroom door in the residence. 4. Plans must show the location and size of all windows and identify emergency escape and rescue windows, including accompanying wells. Window sill height, ladder dimensions and clear space dimensions of wells is required to be listed. 5. Plans must show plumbing isometric and fixture unit count, and location of cleanouts and fixtures, including fixture spacing. 6. Plans must identify any modifications to the existing structural components such as walls, beams, posts and floor joists. 7. Plans must show methods for heating, cooling and ventilation of spaces to be finished. 8. Plans must indicate any area in basement where finished ceiling height is less than 7 feet 0 inches. 9. Asbestos report: Single -Family residential dwellings ("SFRD") — the trigger levels are: 50 linear feet on pipes; 32 square feet on other surfaces; of the volume equivalent of a 55 -gallon drum. A sample floor plan is shown on Page 1. Specific code requirements can be found on Page 3 of this document. PROJECT ADDRESS: 1. Ceiling Heights: If the finished ceiling will be less than T, please consult your Building Department - 2. Emergency Escapes: It ba, -temems. and sleeping rooms must have an emergency escape window or exterior door. Errtergency escape windows with a sill height below grade must be provided with an emergency escape window well and ladder, (For emergency escape window and window well requirements, see page 4.) 3.5moke Alarms and Carbon Monoxide Detectors: Smoke alarms are required in all basernents- If the finished basement contains a sleeping room, a smoke alarm must r>e installed on the ceiling or wall in the steeping roorn and in the hallway or area immediately outside of the steeping room. Smoke alarn-is, added to satisfy the above requirements must be hard -waved with batteq-y back-up, and interconnected wth existing smoke alarms. Smoke alarms are required to be hardwired and interconnected in new and existing ia--droorns, halts and on each level unless removal of interior wall or ceiling finishes would be required- In this case, battery operated deices are acceptable- C.O. detectors are required within 15 ft outside of each bedroom. 4. Feel BUMIng Appliances: Furnaces and water heaters cannot be located in a bedroom or bathroom unless appliances are installed in a dedicated enclosure in which all combustion air is taken directly from outdoors, and a weather stripped solid door equipped with an approved self closing device is installed. If the furnace and water heater are being enclosed, adequate combustion air must be provided for these appliances to operate property. For maintenance purposes, a minimum of 30 inches clear working space must be provided in front of furnaces and water heaters. Maintenance or removal of each appliance must I-,-- possible without removing the other or disturting walls, piping, valves, wiring and junction boxes. 5. Floated Walls: In areas subject tafoor heaving, non-bearing walls on basement floor slabs should be built to accommodate not less than 1-112 inches of floor mavement. A detail of a typical floated wall is included on page 4 of this hand-out. Drywall should be held to a minimum of 1 inch above the stab to allow for movement. 8. Flpehlocklng: Fireblocking must be installed in concealed spaces of wood -furred walls at the ceiling level, at 10 -foot intervals along the tenth of the wall and at all interconnections of concealed vertical and horizontal spaces such as intersection of stud walls and soffits or dropped ceilings- A detail of typical fireblocking is included on the following page of this handout. Fireblocks may be constructed of 1-1f2 inch lumber, 314 inch plywood or particle board, 112 inch gypsum board or fiberglass insulation 16 inches minimum in heigth, securely fastened. 7. Ins[flatioll: A minimum of R-10 insulation is required on basement walls, A minimum of R-21 is required in floors above unconditioned spaces (crawl spaces, etc.). S. Space Under Stairs: If access to the area or space under the basement stairs is provided for storage or other uses, the walls and ceiling of this enclosed space rnust be protected on the im i€de. 9. Bathpoonts: toilets must be provided with a minimum of 21 inches in front of the toilet and 15 inches from the center of the toilet and any sidewall or other obstruction. Showers shall have a minimum inside dimension of 900 square inches, capable of encompassmg a 30 inch circle and be finished 72 inches abolve the floor with non-absorbent materials. See Exceptim Z r2708.1. A ventilation fan is required in toilet rooms and bathrooms with unopenable windows or windows with less than 1.5 SF of openable area. Fans must be vented to the exterior of the structure and may not terminate within 3 feet of an opening. 10. Lighting & Ventilation: Lighting and ventilation are required for any finished portion of the basement. Contact your Building Department for specific requirements The Building Department staff can help you deterntme what is necessary to meet mmimum safety requirements PROJECT ADDRESS:L,z, T to Kcrvidt g ;msdate f cc tWW Resdentat Codeor �� is aft r4mst$tu1 f + 4r dad wit? �rt�trEd ration � katirt : e�C� F heart F"r •, cxxwaleti t� fired ieatls arxt sus at 1S --- dx r, b", ned Ct ttert b'# nter-aks Abrgl tt d tie WAIN WIh ZA lumt$r. -- �— ce x g psavr bowl naltd r, era& s !*ld cva " " , at tom ttaa to ati3 v, mns og gap% as toss xKd r wrwil or { 5 =bt�g� s5 niuti ± 'X4 wa? -- ristin{t n wit — x -IJIN New 3e4 n*tct pat�scxn Wal LNSh MMP -rt 401 "ilil,er e+y 24 5 #eta b m� to alto °max c :t- ar T,ya.•.�.,... :.� ti's £*sitif�'.'t$3rrt� � 1: �'k'3� N� t{7 -�^L*f S:�'t �-.m ""�"`.--� Spacer - swme ft4rress as wall €ate: rrXe n _lee vol a mi rtex;r r err of M v d*s d Sul era V* z Wdor mm- a , ihr b&Wmistr ' ws c qovraw tttt* NN s a �s ~ A,t=y oWed to Kcrvidt g t of f is aft +• Re wit? �rt�trEd F katirt : e�C� ' dx r, t 8" or st petrr "*fit to ri b tw d .. . F-- t�y 3;* Ate Rfuu tv rwt N fWm4V � r� A soar" r Yta f Ss `than {+ sctx# A ^rIMr%r atm 0,04-. 4 tat x rk ttt«s ",:N, A na 3r.t . c mss s : Nt*s. . A s s4 trt � r�ct •s�zs ttaaes 4� names c+�x rti €aa of C t Width G " bo" 1 34 L*jr r t V, jqft G't s ar}3��J C e m . to earl easm w1doat14-, tet -sr- sat Wroo. tt hCity of SEE ATTCHED SHEETS FOR ADDITIONAL REQUIREMENTS COWeat f),' FOR THIS PROJECT -'MMUNITy DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Review is limited to the contents of the plans submitted and any errors or omissions contained herein shall not be construed as permission to allow any conditions to exist in violation of the codes of the City of Wheat Ridge Rough Framing and Wood Requirements 3 The complete rough inspection is to be made after the rough framing, rough electric, rough plumbing, and rough heat and ventilation are complete. The building should be fully enclosed with the roof covering and siding in place. 4 Protection from decay shall be provided in the following locations by the use of naturally durable wood or wood that is preservative treated in accordance with AWPA U1: (IRC R317) 5 Basements greater than 200 square feet and every sleeping room shall have at least one operable emergency and rescue opening or a door to the exterior. 6 Emergency escape and rescue openings shall meet the following requirements: A minimum clear width of 20 -inches, a minimum clear height of 24 -inches, with a total net clear opening of 5 square feet for grade level windows and 5.7 square feet for all others. A sill height of not more than 44 inches measured from the finished floor to the bottom of the clear opening. Window wells for emergency escape and rescue shall provide a minimum net area of 9 square feet with minimum horizontal projection and width of 36 -inches. The area of the widow well shall allow the emergency escape and rescue opening to fully open. (IRC R310) 7 Fire blocking shall be installed to cut off all concealed draft openings in the following locations: (IRC 302.11) A. In concealed spaces of stud walls and partitions, including furred spaces, vertically at the ceiling and floor levels, and at 10 -feet horizontal intervals. B, At interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings, and cove ceilings. C. In openings around vents, pipes, ducts, cable, wires, chimneys, fireplaces, and similar openings that afford a passage for fire at ceiling and floor levels. D. In concealed spaces between stair stringers at the top and bottom of the run, and between studs in line with the run of the stairs at unfinished walls. 8 Ceiling heights for habitable rooms, hallways, bathrooms, toilet rooms, laundry rooms, and basements shall be a minimum of 7 -feet measured from the finished floor to the lowest projection of the ceiling. Non - habitable basements may have a ceiling height of 6 -feet, 8 -inches with clearance below beams and ducts of 6 -feet, 4- inches. Bathroom.may have a ceiling height of 6 -feet, 8 -inches at the fixture front clearance area and over the fixture. (IRC R305.1) 9 All habitable rooms shall be provided with aggregate glazing area for natural light of not less than 8% of the floor area of such rooms. The glazed areas need not be installed in rooms where section (M1507) is 0W vi satisfied and artificial light is provided at an average of 6 foot candles at a height of 30 inches. wheat Ridge 10 Safety glazing shall be installed in the following hazardous locations and be permanently labeled as gudd!090N"sson safety or tempered glazing: glazing panels in doors; glazing enclosing spas, bathtubs or showers; glazing panels adjacent and within 24 -inches of the edge of a door; glazing panels greater than 9 square feet within 18 -inches of the floor; glazing used for railings; glazing used for barriers for swimming pools and spas; and glazing enclosing stairways, landings, and ramps within 36 -inches horizontally of a walking surface. See the Boulder County Land (IRC R308) Heating and Ventilation Requirements 11 A. Habitable rooms must be provided with outdoor openings for ventilation equal to at least 4% of the floor area and shall have heating facilities capable of maintaining 68' at 3 -feet above the floor and 2 -feet from exterior walls. B. The windows need not be openable in a room where an opening is not required to be an egress window and a mechanical ventilation system is capable of producing 0.35 air change per hour in that room, or a whole house mechanical ventilation system provides 15 cubic feet of outdoor air per minute. 12 Bathroom exhaust fans shall exhaust directly to the exterior and must be provided in bathrooms where windows of at least 3 square feet are not provided. The mechanical ventilation must be capable of providing an exhaust capacity of 50 cfm intermittent or 20 cfm continuous exhaust. (IRC R303.3, M1507.4) 13 Appliances and equipment shall be installed in accordance with the conditions of their listing. Manufacturer's installation instructions must be available at the time of the inspection. (IRC G2408.1, M1307.1, M1401.1,(M1902.2) 14 Appliances shall be accessible for inspection, service, repair and replacement without removing permanent construction. 30 -inches of working depth and width shall be provided in front of the control side of an appliance. (IRC M1305.1) 15 Combustion air is required for all liquid fuel, solid fuel and gas appliances. (IRC M1701.1, G2407) 16 Gas burning appliances may not be located in or obtain combustion air from: a sleeping room, bathroom, toilet room, or storage closet unless it is a direct vent appliance or installed in an enclosure that opens only into a bedroom or bathroom in and such enclosure is provided with a solid weather-stripped door, a self-closing device and all combustion air is taken from the outdoors. (IRC G2406.2) Electrical Requirements 17 All hot, neutral, and grounding conductors in electrical boxes shall be tied together with a mechanical connection at the time of rough inspection. City of 18 Recessed lighting fixtures must either be IC -rated or installed in a sealed box in which the insulation is at least 3 -inches from the light fixture. All recessed lights must be tightly sealed or gasketed to prevMti I t Ridge leakage through the fixture into the ceiling cavity. (IRC N 1102.4.5) Building Division 19 Tamper -resistant Receptacle outlets are required in every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room or similar dwelling areas spaced so that no point along the wall line exceeds 6 -feet from an outlet. (IRC E3901, E3902, and 4002.1-4002.14)A Counters 12 -inches in width or wider shall have receptacles placed no more than 20 -inches above the counter top and spaced so no point exceeds 24 -inches from an outlet. B. Island and peninsula counters with a length at least 24 -inches and a width of 12 -inches or greater must be equipped with at least one outlet. C. At least one receptacle shall be installed in a bathroom within 36 -inches of each basin. D. A least one receptacle outlet must be installed in each laundry, basement, attached garage and detached garage with power. F. At least one receptacle outlet that is accessible while standing at grade level and located not more than6- feet, 6 -inches (1981 -mm) above grade, shall be installed outdoors at the front and back of each dwelling unit having direct access to grade. Balconies, decks, and porches that are accessible from inside of the dwelling unit and that have a usable area of 20 square feet. F. Attics or crawlspaces containing equipment must be provided with at least one receptacle outlet within25-feet of the equipment. G. Hallways 10 -feet or more in length. 2,0 Two 20 -amp rated branch circuits shall serve receptacles in the kitchen, pantry, breakfast area, and dining area. At least one 20 -amp branch circuit shall supply bathroom receptacles and at least one 20 -amp branch circuit shall supply laundry. (IRC E3703.2, E3703.3, E3901) 21 Ground fault protection shall be provided on all 125 -volt, single phase, 15 and 20 -amp receptacles in the following locations: bathrooms, garages, unfinished grade level accessory buildings, at exterior locations, crawlspaces, unfinished basements, kitchen counters, within 6ft. of laundry, utility and wet bar sinks, boathouses, hydro massage, spa and hot tub locations. Receptacles must be in a readily accessible location. (IRCE3902, E3902.11) 22 Combination type Arc -Fault circuit interrupters must be installed on all 120 -volt 15 and 20 -amp branch circuit outlets in Receptacle outlets are required in every family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, hallway, closets, and similar dwelling areas. (IRC 3902.12) 23 Smoke alarms shall comply with UL 217. Smoke alarms are to be powered by the building's wiring operated light. (IRC E3903)with battery backup and shall be interconnected so the actuation of one alarm will activate all alarms in the dwelling unit. Smoke alarms shall be installed in the following locations: (IRC R314) A. In each sleeping room; B. Outside each sleeping area in the immediate vicinity of the bedrooms; and C. One on each additional story including basements. 24 Carbon Monoxide alarms are required in a single-family dwelling that has fuel -fired appliance(s), or a fireplace, or an attached garage. The alarm must be installed within 15 -feet of the entrance to each sleeping room. Must be listed by a nationally recognized, independent lab. Plugs into a dwelling's electrical outlet and has a battery backup. They may be combined with a smoke -detecting device if the combined device complies with applicable law. (IRC R315) cm 01 25 Working space must be provided around energized equipment for servicing and maintenance. The e minimum dimensions shall not be less than 36 -inches in depth and 30 -inches in width in front of the wheatRid9 equipment. Working space shall extend to at least 6 -feet, 6 -inches above the floor. (IRC E3405.2) Bt,jjd: go+�15`°n 26 Electrical fixtures installed in wet or damp locations shall be installed so that water cannot enter or accumulate n wiring compartments or other electrical parts. Fixtures installed in wet locations must be labeled "suitable for wet locations". Fixtures installed in damp locations must be labeled "suitable for damp locations" or "suitable for wet locations". Switches or circuit breakers located in wet locations or outdoors must be enclosed in a weatherproof enclosure. Outdoor receptacles must have a weatherproof enclosure and an in -use cover. Cord -connected fixtures, hanging fixtures, track lighting, pendants, and ceiling fans shall not be located within3-feet horizontally and 8 -feet vertically from the top of a tub or shower rim. (IRC E4003.9, E4002.8, E4002.9,(E4002.10, E4003.9, E4003.10,E4003.11) Plumbing Requirements 27 DWV systems shall be tested on compellation of the rough piping installation by water or for piping system other than plastic by air with no evidence of leakage. Either test shall be applied to the drainage system in its entirety or in sections after rough piping has been installed .1) Water test 10 feet above the highest fitting connection or to the highest point of the completed system. The system shall prove leak free for 15 minutes. 2) Air test shall maintain 51bs of pressure for 15 minutes. 28 All piping must be inspected and tested prior to concealing. It shall be protected against physical damage and it must be approved for use and bear the identification of the manufacturer. (IRC P2503, P2603, P2608.1) 29 Bathtubs, walls above bathtubs with shower heads, shower floors, and shower compartments shall be finished with a non-absorbent surface which extends to a height not less than 6' above the floor. Showers must have a minimum 900 square inches of interior area and a minimum dimension in each direction of 30 -inches. Shower valves must be pressure balance/thermostatic mixing valves. Shower receptors shall have a curb threshold not less than 1 -inch below the sides and back of the receptor. The curb shall measure a minimum of 2 -inches to a maximum of 9 -inches above the top of the drain. (IRC R307, P2708, P2709) 30 The centerline of toilets or bidets shall not be less than 15 -inches from adjacent walls or tub. Toilets, bidets, and lavatories must have a minimum clear space of 21 -inches in front of the fixture. Lavatories require a 4 -inch clearance to wall or to a toilet. (IRC P2705) 31 Showers and tub/shower combinations shall have control valves of the pressure balance, thermostatic mixing or combination pressure balance/thermostatic mixing valve types with high limit stop per ASSE 1016 or CSAB125.1. Tubs shall also have a control valve as listed for a shower or a water -temperature -limiting device that conforms to ASSE 1070. The high limit stop for a device shall be set to a maximum of 120°. (IRC P2708.3,P2713.3) 32 Shower doors shall have safety glazing; hinged show door shall open outward. (R308.4.5, P2708.1) ow of Wheat Ridge 13ui1din9 Division Insulation 65 R-20 Walls R-49 Ceiling R-19 Crawlspace Window U -Factor .32 Floor R-30 66 Supply Ducts in attics shall be insulated to a minimum of R-8. All other ducts shall be insulated to minimum R-6. ( N 1103.2. 1) 67 Combustible insulation shall be separated a minimum of 3 -inches from fan motors and heat -producing devices. Insulation shields must be provided where vents pass thorough insulated assemblies and must terminate at least 2 -inches above attic insulation materials. Can lights must be airtight if located in the building envelope. (G2426.4) 68 Class I or II vapor retarders are required on the interior side of the insulation in framed walls, floors and roof/ceilings of the building's thermal envelope. The vapor barrier is not required in construction where moisture or freezing will not damage the materials, or where the framed cavity (or space) is ventilated to allow moisture to escape. A vapor retarder is not recommended on a concrete basement foundation wall or in a shower /bath compartment (IRC 702.7, R702.7.1). Wallboard Requirements 69 Enclosed accessible space under stairs shall have walls, under stair surface and any soffits protected on the enclosed side with %-inch gypsum board (IRC R302.7). 70 Nail spacing for gypsum board % gypum board Ceiling 16oc, 7", nails 12", Type S screws '/z wall spacing 24"OC, 8" nail spacing. 12"OCscrews. 5/8 ceiling board 16"OC, 7"nails I 2"spacing, screws 240C 8". 72 Water-resistant gypsum backing board used as the base or backer for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178 or C1278. It is permitted on ceilings where framing spacing does not exceed 12 -inches o.c. for %-inch thick or 16 -inches o.c. for 5 8 -inch thick gypsum board. Water-resistant gypsum board shall not be installed over a vapor retarder in a shower or tub compartment and may not be used where there will be direct exposure to water, or in areas of continuous high humidity. All cut and exposed edges shall be sealed. (IRC R702.3.8) 73 Floor assemblies, not required elsewhere in this code to be fire resistance rated, shall be provided with a inch gypsum wall board membrane, 5/8 inch wood structural panel membrane, or equivalent on the underside of the floor framing member.(IRC 501.3) City of 7500 W. 29'x' Ave Wheat Ridge, Co 80033-8001 Wheat Ridge Building Division ANMOM Vo t� �7f w. ITT 6ity 4f - - -- -- - - - - taw - f__L 9P --- - ------- i q I ------ - -- -- 4p Z5 . . ...... ..... +'IT-,- Nf I N . il , loon - x INSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: --2 L)` ADDRESS: `7/r � � JOB CODE: Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers % 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit % 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector �nitiaLs Comments 301 Rough Framing % 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection '05 Insulation Mid -Roof Lath / Stucco -+Tical Residential Commercial 'dential -,cial -OR ADDITIONAL INSPECTIONS PERMIT: /, '3! (/ ADDRESS: "-,//c, JLL JOB CODE:` Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 403 Final Electrical Residential 317 Rough Mechanical Commercial 404 Final Electrical Commercial 318 Boiler / Furnace 406 Final Mechanical Commercial 319 Hot water tank 407 Final Plumbing Residential 320 Drywall screw and Nail 408 Final Plumbing Commercial 321 Moisture board / shower walls 410 Final Window/Door 322 Rough Grading 411 Landscape/Park/Planning* 323 Miscellaneous 412 Row/Drainage/Public Works** 413 Flood plain Inspection** Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential T7 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 "For ROW and drainage inspections please call 303-235-2861 'For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 0% l 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Wor s, Fire and Buildir before a Certificate of Occupancy is issued. Approval of the Final Building Inspection doeF- constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: q IFI Job Address: 10 S �,�, Z " 71 Permit Number: 'Z o l $ c)o _5 ! z- ❑ No one available for inspection: Time AMI(PM -- t Re -Inspection required: Yes -'No When corrections have been made, call for re -inspection at 303-234- Date:- Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 1-10-31floc+_ 21M'116�- Job Address: Permit Number: ILI ❑ No one available for inspection: Time C� Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: a? Inspector: )eAl alkr---- DO NOT REMOVE THIS NOTICE GAS ©4 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 0 3¢ E k q10 i t Job Address: 4 L / aqvi vL Permit Number: / 9 OG 3% ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes �N_O) When correct'ons have been made, call for re -inspection at 303-234-5933 Date: � M, Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:' >� Job Address: Permit Number: 061 � 3 ❑ No one available for inspection Time._. + t`AM/P Re -Inspection required: Yes CN22� When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: 307V > �� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ' 1r r"��f�' Job Address: 7An 004- Pr Permit Number: 3 L/ ❑ No one available for inspection: Time - W. `'AM%PM F Re -Inspection required: Yes/ No f. When corrections have been made, call for re -inspection at 303-234-5933 Date: c-,-?'` 'ice Inspector: DO NOT REMOVE THIS NOTICE � City of Wheat Ridge Residential Addition PERMIT - 201800314 PERMIT NO: 201800314 ISSUED: 02/08/2018 JOB ADDRESS: 7105 W 29th PL EXPIRES: 02/08/2019 JOB DESCRIPTION: Sun room replacement only. Existing foudations, planning. Site and floor plan already on file. Three season sun room. Unheated and replacement only. *** CONTACTS *** OWNER (720)252-5522 TAVANO CHRISTOPHER P SUB (720)447-1152 Thomas Stephen Wiles 160246 Modern Classic Remodelers Inc *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 15,500.00 FEES Total Valuation 0.00 Plan Review Fee 194.61 Use Tax 325.50 Permit Fee 299.40 ** TOTAL ** 819.51 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authoriAdd to obtain this permit and perform the work described and approved inconjunction with this ermit. I further attest that -1 --am ally a &rized to include 1 entities named within this document as parties to the work to be wo prfo ed and that all o per rm disclosed in this do ument and/or its' accomp nying approved plans and specifications. Sign tu'r"'Nof OWNER or CONTRACTOR (Circle one) 'Date c I I . This permit was issued based on the information provided in the pzrmit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2, This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and maybe subject to a fee equal to one-half of the originalpennit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5, The permit holder shall notify the Building _and ection Services Division in accordance with established policy of all required inspections and shall not proc Id or conceal worrwithout written approval of such work from the Building and Inspection Services Division. 6. The issuance orgranting of a rmit shall not be construed to be a permit for, or an approval of, an violation of any provision of any apphcab ode �an,irdm lation of this jurisdiction. Approval of work is subject to field inspection. ' Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City Of 1)9r" Wheat Rj,q� l l � COMMUNITY DEVELOPMENT Building & Inspection Services Division,(; 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 VRe r Inspection Line: 303-234-5933 Email: permits(a.ci.wheatridge.co.us I FOR OFFICE USE ONLY Date: /I 1 r + Plan/Permit # ;;�Ol 19 Doi �y Plan Review Fee: %w�9�i.b/ Building Permit Application Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: ( o S` L ,,2 `) ` P L L-% 1i aw it uo (u F p O j 3 Property Owner (please print): � �1�/ 7—,4✓t),jo Phone: Property Owner Email: L,o i A VA AJ 0 f� (v �i �+ �, cg M Mailing Address: (if different than property address) Address: f Architect/Engineer: `-T-eA l S /Zc�C_ JL'S L L/P* -- S ff o / 'foo Architect/Engineer E-mail: Phone: F"// (o Contractor: Aav`k1,-i z_l, le i Contractors City License #: — w h _ Tr 4t CIZC J Phone: ?J 0 S" 1 S ­ F 5`0 Contractor E-mail Address: L.v i � s 7-14a retia -s- JL 4 F%' (a m4 r 1. e c of For Plan Review Questions & Comments (please print): CONTACT NAME (please print): �i c k Li,4i1e-,,1 —Phone:�3 CONTACT EMAIL(p/ease print): _, � 4 o6 tk s Aid Sub Contractors: Electrical: Z, A L K— L Q i C_ Plumbing: Mechanical: W.R. City License #P �� W.R. City License # W.R. City License # iv wL r ic. Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION .. ❑ WINDOW REPLACEMENT ❑ C©Mf IER _ . I A C< $QRY STRUCTURE (Garage, shed, deck, etc.) xj-'RESIDEN`rLACCES ORY STRUCTURE (Garage, shed, deck, etc.) Q MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMET� OTHER (Describe)_ 3 L -A -S a ,%J (For LL projects, please provide a detailed description of work to be;performed, including Orrent use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) lo -e -,! J0rt <,VT eAJI S:1 nI1LpD ;i+�- 4P l✓ltc.ti p t 1�Xlyi c,v� r 41 i , J< Sq. FULF 16 s j-- Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) $ t!- C) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. `', 0. t-.. ; �. CIRCLE ONE: (OWNER) (CONTRACTOR) Sianature (first and last name): 1 10 REPRESENTATIVE) of (OWNER) (CONTRACTOR) DEPARTMENT USE ONLY DATE: G ZONING COMMMENTS:� 2 ,QJ�*"�f �� OCCUPANCY CLASSIFICATION: v Reviewer: - c r�1 BUILDING DEPARTMENT COMMENTS: ) � } h �X ` v t) - �� )2 Reviewer: Building Division Valuation: $. IS, 9:)D V RECEIVED JAN 3 1 2018 Per LEGEND: $ LIGHT SWITCH RECEPTACL �� FAN FRAME COLOR: WHITE FASCIA/TRIM: WHITE INTERIOR KP: WHITE EXTERIOR KP: WHITE SKIN TYPE: TEMKOR 4,IW ,IFT I 6' PATIO DOOR Reviewed for Zoning Compliance by the City of Wheat Ridge Planning Division APPROVED x By: SC: TZ DATE: 2 j c / q COMMENTS: EXISTING HOME 3 I i I 0 z z a 8, 8"A Z 1 � 3, WINDOW 36" WINDOW 36" WINDOW 36" WINDOW U Z 00 (n MO00. m I a00 I 0 p i N of Of � a00co J U ¢ 3 v n r O o w D1 - 0 5O ~ O J = Q N 0 d L, w —19'-90 $ Al J N FLOOR PLAN NOTE: ENCLOSURE NOT TO BE USED AS A PERMANENT LIVING AREA O a n N n rn to 3 Z 0 n .Q NOTE: THE SIDE WALL ATTACHMENT 0 i TO HOUSE IS A NON -LOAD O a BEARING CONNECTION. z Q m PROPERLY CAULK BOTH SIDES rc Q OF ALUMINUM EXTRUSION AT THIS CONNECTION. W ~ 0 0 3)q (City OfWheat Ridge uilding Divisc.r7 City of Wheat Ridge uilding Diviso #12 SMS @ 6"O.C. RAFTER CAP MAX. Z ROOF SEAL O onto O �04 Z p N SPLIT HANGING RAIL AS SHOWN a ROOF PANEL00 Co 3 ALONG THE THERMAL BREAK Oo = SPACE TO ALLOW RAFTER TO SLIDE 2 "ow w INTO PLACE z o X n m ROOF SEAL N a (2)—#14 WOOD LAG SCREWS @ 16" N O.C. TO PENETRATE SOLID SOLARIUM RAFTER WOOD 1 3/4" MINIMUM J Z HANGING RAIL SNAP W J Q U m CONTINUOUS HANGING RAIL a N rn 3 z 0 DETAIL'B' D � O =2 a (L z5.: z Q m � Q p ~ Q a City of Wheat Ridge uilding Diviso V SOLARIUM INSTALLERS LAYOUT SKETCH VERIFY ALL FILL MEASUREMENTS BEFORE CUTTING NOTICE: * DBL -CHECK B THIS JOB HAS NOT BEEN CONFIRME PLEASE FAX AN APPROVAL WHE�RORDIER. RELEASE APPROVED BY—ZL____ Fax: (586) 412-6090 (converts to email) CUSTOMER: NATIONWIDE SUNROOMS JOB NAME: (S) TAVANO 3 5/8" WALLS ALUM. HEADER w/ WOOD INSERT OVER DOOR M LO 104 A M �1 to W 36 C z Q z NOT TO SCALE Cagy of 1NY1eat Ridge ilding 71.625 36 [] 36 [] 36 [` LJ[� 1--- NO BOT RHO T —� 237 Al 104.0 87.0 --- L 17W6119 DETAILED BY: PHIL TARAVELLA on 12/12/17 M LO 104 A M �1 to W 36 C z Q z NOT TO SCALE Cagy of 1NY1eat Ridge ilding city ol \j%i r, e a t P. it 9p' wilding Giviso 4SOL3 SEE ATTACHMENT DETAIL 'B' SEI ""L " FIG. K RAL TEMO ALUMINUM CLAD STRUCTURAL UMI T EM ALUMINUM 7LS INSULATED ROOF GI ASS PANELS I S 0 T OC N rULA ED R EXISTING z 00 00 :7 cn 4SOL.3 4SOL3 STRUCTURE C6 00 2 ocol 7'--3" 0 Co C4 0 04 FIG. 13 ir Z co 00(D cc U) < 0 m z 0 0 L11 W 0 Z 't C 5< 0 J x: < 04 0 a. L� O RAO -Y.- ZEXISTING CONCRETE SLAB Z SECTION °A' WJ O0 Z f zM ROOF PANELS: 3", 0.019, 2 LB.#, ROOF LOAD: 30 P.S.F. city ol \j%i r, e a t P. it 9p' wilding Giviso co cd r) 5i o o c, co I (o 0 �t 'D I 0 w N Z oD ob U) O 2 0 C) �- 0 LJ U, z 4 o < NUD_ ti O A/I ALUM. HEADER ci ALL TEMO SUNROOMS ARE Al DESIGNED IN ACCORDAN e WITH THE12""C NOTE ALL OPERATINGTAfle 490NG PRODUCTS SUPPLIED BY TEMO SUNROOMS INCLUDE TEMPE RE ELEVATIONSHPG -2000 GLASS THAT CONFORMS W < WITH SECTION R308 OF THE IRC. 0 0 0 w • UL 58SL ' CALIFORNIA FACTORY BUILT HOUSING CMJ -TEM 1-4 • FLORIDA PRODUCT APPROVAL 5505 ' FLORIDA PRODUCT APPROVAL 3857-R1 ' FLORIDA PRODUCT APPROVAL 3521-R1 � h a ' FLORIDA PRODUCT APPROVAL 6391 • CITY OF LOS ANGELES STANDARD PLAN NUMBER 6 ' FLORIDA PRODUCT APPROVAL 7086 • FLORIDA PRODUCT APPROVAL 7062 O N M _ fL' [D W M N O tL ~ U � O O W W F Q W � O ~ W O Q N Q O d p U z = z i r 2 � Q o •Q se us a Q 3 SPECIFICATIONS FOR of 'K W DIeatR gge �MUNny mr -M Q PmENT . J SUNROOMS AND PATIO COVERS WITH APPROVED gusE Reoriented for Code Compliancelo m C3.625 INCH WALL MULLIONS ., a z U � i Pla Examiner Date „ • to O M PACE NUMBER yaiidity of oermil� The issuance of o perms w oDPraval a/pions specifications and computations shall not be a permit /or, or an approval of, any violation to Permit � < M i m rJC any of the provisions of the building code or o/ any City O'dinonces. presuming to give authority to violate of cancel the provisions of Nst Auifdirq o m COVER SHEET INDEX 0 F SHEETS codes o< other ord ponces of the City shah not b< valid. O o zo U a FLOOR PLANS, ELEVATIONS and ROOF PLANS r to m N 4TEM01 4TEM02 3.625" SUNROOM SYSTEM ROOF DETAILS and NOTES Q 4TEM03 3.625" SUNROOM SYSTEM WALL DETAILS 4TEM04 3.625 SUNROOM SYS EM CROSS SECTION and ATTACHMENT DETAILSo O N 4TEM05 3.625 SUNROOM SYSTEM WIND LOAD CALCULATIONS LLI w LICENSE Reviewed for Zoning Compliance by the ` o�P�p S ES/y 66 O City of Wheat Ridge Planning Division -,r/�" o .•'y vim. JP 0% APPROVED : 42005 DATE: MAY 2017 cc �• • �� 13 5� �(� 1 : LUAY ESH O, PE 20400 HALL RD [;LINTON 7N4, YI 48038PH: (10D) 344 -Bee• •• { • •/ L r S' ONp�, DATE: Z%1 / �g ,,,,, COMMENTS: �� � � �I PROF®ONAL ENG NEER CO Lk. /42005 DRAYN BY: CUSTOMER NATNVADE aN;�k i� 1`� l DWG. NO.: 4TEM01COVERCO COVER SHEET ROOF PROJECTION I F ROOF PANEL z 18" 12" TYPICAL MAX. ao D j pal o - O MULLION SPACING NOT TO EXCEED 8 FEET a A A,AesSION PATIO COVER END WALL ELEVATION ROOF PROJECTION COVER END WALL ELEVATION ALL SECTIONS & DETAILS REFERENCED HERE ARE SHOWN ON SHEETS 4TEMO2, 41-EM03 AND 4TEM04. 12" TYPICAL EXCEED 8 FEET ROOF PANEL SPACING NOT TO EXCEED 8 FEET PATIO COVER FRONT WALL ELEVATION ROOF PANEL MULLION SPACING NOT TO EXCEED 8 FEET PATIO COVER FRONT WALL ELEVATION w Z Q a C, O CD O m 0 Q Z Q N / EXISTING STRUCTURE 12" TYPICAL VARY TO SUIT r TYPICAL STUDIO ROOF PATIO COVER PLAN EXISTING STRUCTURE E Q E E m OPTIONAL DOOR w OPTIONAL DOOR C> m J Q C> O C, CD 0 O 12" TYPICAL VARY TO SUIT r TYPICAL STUDIO ROOF PATIO COVER PLAN EXISTING STRUCTURE E Q E m w OPTIONAL DOOR m J Q C> O N V) O O VARY TO SUIT ( 12" TYPICAL POSSIBLE L 0O PANEL PROJECTION TYPICAL GABLE ROOF PATIO COVER PLAN City of eatr ICR�1__ z a Q Z J O ft� F- 0 O0 J � W DATE MAY 03, 2017 WAY ESHO, PE 20400 HALL RD CUNTON R1P, MI 4803! PH: (800) 344-83H PROFESSONAL ENGINEER 00 U- {42005 DWG. NO.: 4TEM01NTCO 1 OF 5 ALUMINUM CAP FLASHING ALUMINUM SK INSTALL #6 SMS AT 4" ON CENTER a�. 0.032" ALUMINUM 0.032" ALUMINUM ROOF PANEL AT CATHEDRAL PEAK WITHOUT BEAM DETAIL ROOF HANGING RAIL MOUNT W1(1) 1/4' x 3' LAG SCREW 8 O.C. CAULK EXT. EDGES 18" METAL FLASHING (SCREW & CAULK) _ REMOVE EXISTING DRIP EDGE EXISTING TRUSS ROOF WITH SHINGLES OVER FELT PAPER TRUSS OR RAFTER AT 16" ON CENTER 1 INSTALL 7/16" OSB TO NEW 2X4 ATTACH NEW 2X6 FASCIA BOARD ADD 2 x 4'S WHERE REQUIRED USING (2) 1/4"X3' 0 12" 0/C ----- LAG SCREWS INTO EACH RAFTER OR TRUSS ===_ 18"---1 TEMO RECOMMENDED SUNROOM MAX EXISTING ROOF ATTACHMENT TO THE EXISTING EXTERIOR SOFFIT. SOFFIT REINFORCED AS SHOWN WALL ROOF TO OVERHANG REINFORCING AND ATTACHMENT DETAIL /8 SMS 0 6'O.C, MAX O.C. TO PENETRATE SOLID WOOD 1 3/4' MINIMUM ALUMINUM SKIN 0 z F En w UL APPROVED FIXTURE BOX CEILING FAN MOUNTING DETAIL APPUCATION OF SHINGLES TO THE TEMO ROOF SYSTEM AS SHOWN WILL NOT VOID THE TEMO SUNROOMS WARRANTY DOTER ALUM. ROOF CLEAT COVER EXISTING RESIDENCE OUTER ALUM. ROOF CLEAT 80/2' I.G. r=te SMS 0 6'O.C. 5 ROOF PANEL/WALL PANEL/WALL ATTACHMENT SHINGLES TO ROOF PANEL ATTACHMENT DETAIL INNER VINYL ROOF CLEAT LALAMINATED ROOF �PANEL ROOF PANEL SPLICE lul VGLES USING FIVE SHINGLE. NTINUOUS COVERAGE SNOW & ICE SHIELD MINIMUM 6" SEAM LAP )F PANELS GENERAL NOTES & SPECIFICATIONS 1. THIS ENCLOSURE SYSTEM IS TO BE INSTALLED UNDER THE ROOF PANEL SHOWN ON DRAWING NO. 4TEM04 OR UNDER A CODE -APPROVED EXISTING ROOF. 2. DESIGN LOADS: SEE TABLES FOR DESIGN LOADS AS SPECIFIED PER THE 2012 INTERNATIONAL RESIDENTIAL CODE AND THE 2012 INTERNATIONAL BUILDING CODE. 3. FASTENERS: SCREWS SHALL BE SIZES SHOWN AND SHALL BE STAINLESS STEEL, ZINC PLATED, GALVANIZED STEEL OR 2024-T4 ALUMINUM. DO NOT USE ALUMINUM FASTENERS INTO ACQ LUMBER. 4. ALL STRUCTURAL COMPONENTS OF THIS SUNR00M SYSTEM EXCEPT SOLID PANELS) ARE OF ALLOY & TEMPER 6063-T6 UNLESS SPECIFICALLY NOTED OTHERWISE. 5. ALL EXTERIOR PORTIONS OF THE SOLID WALL PANEL WHICH ARE SUBJECT TO WATER INTRUSION SHALL BE FULLY CAULKED. 6. OPENINGS IN THE WALL MAY BE COVERED WITH A WIND BREAK MADE OF TEMPERED GLASS WITH A MINIMUM THICKNESS OF 1/8 INCH THAT COMPLIES NTH THE CODE. 7. WHERE THE ROOF PANEL SPAN IS PARALLEL TO THE EXISTING WALL OF THE RESIDENCE THE ADEQUACY OF THE EXISTING WALL SUPPORT STRUCTURE (STUDS, HEADERS, BEAMS ETC.) SHALL BE VERIFIED BY AN INDEPENDENT SOURCE FOR THE ATTACHMENT OF THE RIDGE BEAM. THE ADEQUACY OF THE EXISTING FRAMING IS NOT A PART OF THIS DESIGN OR APPROVAL B. THE BEARING SYSTEM MULLIONS HAVE BEEN DESIGNED FOR LOAD COMBINATIONS REQUIRED BY THE 2012 INTERNATIONAL RESIDENTIAL CODE. 9. ALL ALUMINUM IN CONTACT WITH DISSIMILAR MATERIALS SHALL BE PROTECTED PER CODE. 10. EXPANSION ANCHORS SHALL BE "HILTI KWIK-BOLT II" ANCHORS, "TRU-FAST ZAMAC NAIUN', TAPCON FASTENERS OR EQUIVALENT. WOOD LAGS SHALL BE 1/4" BY 3' GALVANIZED LAG BOLTS. 11. ALL EXISTING WOOD SHALL HAVE A MINIMUM SPECIFIC GRAVITY OF 0.49. 12. SEE TABLES ON SHEET 4TEM05 FOR DESIGN WIND LOADS. 13. ASPHALT SHINGLES OR LIGHT WEIGHT TILE SHINGLES NOT EXCEEDING 7 POUNDS PER SQUARE FOOT MAY BE INSTALLED ON THE ROOF PANELS IN ACCORDANCE WITH TAS 100-95, TEST PROCEDURES FOR WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS, TEST REPORT DATED JUNE 5, 2006. 14. ALL OPERATING GLAZING PRODUCTS SUPPLIED BY TEMO, INC. INCLUDE TEMPERED HPG -2000 GLASS THAT CONFORMS WITH CHAPTER 24 OF THE BUILDING CODE. 15. WHERE SUPPORT PROVIDED BY A CONCRETE SLAB IS PERMITTED BY CODE, THE CONCRETE SLAB (NEW OR EXISTING) SHALL BE IN GOOD SOUND CONDITION, MEANING THE SLAB WILL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI, HAVE NO EVIDENCE OF EXTENSIVE CRACKING, WATER SEEPAGE, OR UNSTABLE FOUNDATION CHARACTERISTICS AND HAVE A MINIMUM THICKNESS OF 3.5 INCHES. TABLE "A": MAXIMUM ROOF PANEL SPANS* DESIGN PANEL DESIGNATION T-3-2-32 T-4.25-2-32 T-6-2-32 LOAD 20 PSF SNOW LOAD 14'-9" 17'-9" 22'-3" 120 MPH WIND 25 PSF SNOW LOAD 13'-0" 16'-6" 20'-3" 120 MPH WIND 30 PSF SNOW LOAD 12'-2" 15'-3" 18'-6" 120 MPH WIND 35 PSF SNOW LOAD 11'-6" 14'-4" 17'-3" A 120 MPH WIND �,,;,• r, 1; ," * MAXIMUM PANEL OVERHANG IS 1'-6" MINIMUM ROOF PANEL SLOPE IS 2% u� a o N CT F CT M� M Dm 0 I- L) 0 0 0 o H Z +� F W z Z a < Q a In a z 25 F5 W J W m a � a jB F - x � Z � Q J K N F v a 4J4 2 m M 0 U Z a r E� i 0 IDM 0. OD N "k Z M O 0 O z o Z m O z o J C) C) o I to m p N aI O a`0D �Ln a 0 0 0 N J a O O w cn 0 � Z L,_. O (� o z � o N Q Co LL I ri ~ r DATE: MAY 03, 2017 WAY ESHO, PE 20400 HALL RD CUNTON TMP, MI 46038 PH: (900) 314-113" PROFESSIONAL 04UNEER CO Ua 042005 DWG. NO.: 4TEM02NTCO 2 O 5 P00 U. VO�:P�S.E, :.J 42005 FULL HEIGHT MALE AND FEMALE #8 SMS 0 TOP, BOTTOM, & 0 24 O.C. BETWEEN Z#B SMS 0 TOP AND BOTTOM CHANNEL WINDOW JAMB FULL HEIGHT MALE AND FEMALE L#8 SMS 0 TOP Al BOTTOM CHANNEL TRANSOM JAMB — SOLID PANEL FULL HEIGHT MALE AND FEMALE L#B SMS 0 BASE AND TOP CHANNEL PANEL ADAPTER AT SOLID WALL PANEL O SLIDING WINDOW 0 AXED GLAZING MALE / FEMALE MULLIONS l�`J ;HT IND MALE #B SMS 0 TOP, BOTTOM, & 0 24' O.C. BETWEEN EIGHT AND MALE SOLID PANEL FULL HEIGHT MALE AND FEMALE L#8 SMS 0 BASE AND TOP CHANNEL PANEL ADAPTER AT� SOUR WALL PANEL rD FEMALE/WALL STUD/MALE l� J FULL HEIGHT FULL HEIGHT MALE FEMALE FULL HEIGHT FULL HEIGHT #8 SMS 0 TOP AND FULL HEIGHT MALE FEMALE BOTTOM CHANNEL RACEWAY CAP #8 SMS 0 TOP AND FULL HEIGHT BOTTOM CHANNEL C RACEWAY CAP #8 SMS 0 TOP, BOTTOM, & 0 O.C. BETWEEN L FULL HEIGHT RACEWAY WINDOW JAMB - LFULL HEIGHT RACEWAY TRANSOM JAMB - FULL HEIGHT FEMALE SOLID WALL PANEL OR MALE AND TOP CHANNEL CORNER D (14 WOOD SCREWS RESIDENCE OR TOGGLE BOLTS 0 16'O.C. CONNECTION ® HOUSE lCJ FULL HEIGHT FULL HEIGHT MALE#8 SMS 0 TOP AND FEMALE BOTTOM CHANNEL FULL HEIGHT \ � RACEWAY CAP FULL HEIGHT RACEWAY PANEL ADAPTER 1 0 SUDING VWNDOW 0 FlXED GLAZING L SOLID PANEL 0 SOLID WALT PANEL MALE/RACEWAY/FEMALE MULLIONS SIRS 0 TOP ) BOTTOM CHANNEL n a o O N O _ M M Um M m 0 L) U O O O ZZOFJ � Q Q Q a ? o N a o o F5 am��s5 az m a v5 c7 x � W Z W U la] 0 DD Va co Z U v.o co ,o M D- °0 = a N n M o I Oz 00 0 0 z o_ U 0 0 e 00 N I O00a�0 0 g 0 N m O O D_ a In Z J W Q F- W Ln V) N >- LD (n MAY 03, 2017 LUAY ESHO, PE 20400 HALL RD CUNTON TWP, MI 48038 PN: (800) 3M-/368 PROFESSIONAL ENGINEER CO Lk. #42005 DWG. NO.: 4TEM03NTCO 3OF5 u- ao � N O M 1/4' X 3" LONG LAG BOLTS DO � DO w 0 120 MPH WIND SPEEDS In o #12x4" SMS W/2" O.D. ALUMINUM WASHER LOCATE 1 -ANCHOR 4" EACH v & NEOPRENE INSERT SPACED ® 12" O.C. I SIDE M AND AT i6• D.C. o BETWEEE N EAACH CH MUWON. o BASE/WALL CAP SAME AS BEARING EXPANDER o w TO MULLION w O BASE SPLICE fv fo o o TO BE B" MINIMUM N FROM VERTICAL MULLION a� W 2-#8 TEK SCREWS INSULATED STRUCTURAL _ N F EACH SIDE OF MULLION DECK PANELS 120 MPH WIND SPEEDS ALUM. FLASHING J l m BEARING WALL SECTION ON TEMO NER APPROVED DECK PANELS CONTINUOUS PANEL GUTTER e=�z� T T}IRU o Z W/#8 SMS @ 12"O.C. TOP & /� Z a < 3 v BOTTOM TO ROOF PANEL / < 1/4" X 3' LONG LAG BOLTS 0 120 MPH WIND SPEEDS m a LOCATE 1 -ANCHOR 4' EACH < <� SIDE OF MULLION AND AT 16' O.C. 6 } WALL CAP SPLICE TO BELn 1'-6" MAX. OVERHANG BETWEEN EACH MULLION. 0 a e W OVER THE VERTICAL MULLION w� 0 a J BASE/WALL CAP SAME AS BEARING EXPANDER w TO MULLION TOP EXPANDER SHALL HEADER z BTO m BEAR FIRMLY ON MULLION z BESBUMINIMUM SECTION PRIOR TO INSTAL- z FROM VERTICAL MULLION LATION OF FASTENERS A THRU C a a EXIST. OR NEW WOOD DECK IN GOOD CONDITION �� _ m 1/4"0 EXPANSION ANCHORS D z ALUM. FLASHING v... 120 MPH WIND SPEEDS — CD m LOCATE 1 -ANCHOR 4" EACH z N a SIDE OF MULLION AND AT 16" O.C. - M BETWEEN EACH MULLION. SILL BEARING WALL SECTION J2 1 Z m O ON WOOD DECK Z BASE/WALL CAP o 'o - SAME AS BEARING EXPANDER SAME z N N TO MULLION 1/4.0 EXPANSION ANCHORS o w _w 0 120 MPH WIND SPEEDS N ` BASE SPLICE N LOCATE 1 -ANCHOR 4" EACH SIDE OF MULLION AND AT 16' O.C. [' 1 TO BE 8" MINIMUM w _ BETWEEN EACH MULLION. FROM VERTICAL MULLION o J w BASE/WALL CAP d N EXIST. OR NEW CONCRETE ¢ = SAME AS BEARING EXPANDER SLAB IN GOOD CONDITION TO MULLION Q J � BASE SPLICE O Q TO BE 8" MINIMUM Do FROM VERTICAL MULLION 0 ZO � EXIST. OR NEW CONCRETE e d c 1= F - SLAB IN GOOD CONDITION U) w W ,�,PpO Lic �_ z \ 4 (n N c S. Q • BEARING WALL SECTION J3 DA MAY 03, 2017 42005 ; ON CONCRETE SLAB of • 1" MIN. ®1/4"�A G,cy 2D400 HALL RD r • ANCHORS • •• f'1,.t\LAS" CUNTON TWP, MI 48038 ••• N Al- `n1 P.i�� V PROFESSONAL MNEER M LJc. 042005 DRAWN BY: BEARING WALL SECTION g °6'-a CUS WER: NAINWIDE DWG. NO.: 4TEM04NTCO 4 O 5 Wind Calculations for Standard Mullions (206 & 306) Wind Speed (80, 90, 100, 110, 120, 130, 140, 150) 120 Exposure (B, C, D) B Calculated Wind Pressure 24 W J W m Q K , z � a Male—Female Mullion Male—Stud—Female Mullion Male—Raceway—Female Mullion a Q o r m�Q33 CO I1 VZ_ (.0 UJ M I m I to 5L M I 0 DO Z LECO Z O J :� U O I m N O I a 2 O O a O N libel Ak- S ;—/ Section OK Section OK MAY 03, 2017 WAY ESHO, PE 20400 HALL RD CUNTON TNF, MI 48038 PH: (800) 344-M8 PROFESSIONAL ENGINEER CO U-' #42005 DWG. NO.: 4TEM05NTCO 5 O 5 Maximum Mullion Height(ft) 7 Maximum Mullion Height(ft) 10 Maximum Mullion Height(ft) 12 Centroid (in) 1.8282 Centroid (in) 1.8264 Centroid (in) 1.8502 Moment of Inertia (in�4) 1.3283 Moment of Inertia (in"4) 2.4763 Moment of Inertia (in^4) 3.7152 pp011�F �O�•.•••••.. NS ection Modulus (in�3) 0.7266 Section Modulus (in^3) 1.3558 Section Modulus (in^3) 2.0080 s. Esy':;cQ Iculated Moment (Ib*in) 8820 Calculated Moment (Ib*in) 18000 Calculated Moment (Ib*in) 25920 . °: A owable Fb (psi) 15000 Allowable Fb (psi) 15000 Allowable Fb (psi) 13500 42005 ,�'C culated fb 12138.73 Calculated fb 13276.29 Calculated fb 12908.37 libel Ak- S ;—/ Section OK Section OK MAY 03, 2017 WAY ESHO, PE 20400 HALL RD CUNTON TNF, MI 48038 PH: (800) 344-M8 PROFESSIONAL ENGINEER CO U-' #42005 DWG. NO.: 4TEM05NTCO 5 O 5 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: '>n 9 3I> ❑ No one available for inspection: Time ' AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 r Date: �� � ��ll Inspecto� % l�l� i DO NOT REMOVE THIS NOTICE " ® City of Wheat Ridge Residential Roofing PERMIT - 201709319 PERMIT NO: 201709319 ISSUED: 11/29/2017 JOB ADDRESS: 7105 W 29th PL EXPIRES: 11/29/2018 JOB DESCRIPTION: Permit for reroof: Install synthetic underlayment, 30 squares Owens Corning Asphalt shingles *** CONTACTS *** OWNER (720)252-5522 TAVANO CHRISTOPHER P SUB (720)690-1288 David Cole 090167 Mountain Range Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,710.00 FEES Total Valuation 0.00 Use Tax 161.91 Permit Fee 172.60 ** TOTAL ** 334.51 *** COMMENTS *** *** CONDITIONS *** midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. PERMIT NO: JOB ADDRESS: JOB DESCRIPTION City of Wheat Ridge Residential Roofing PERMIT - 201709319 201709319 7105 W 29th PL Permit for reroof ISSUED: 11/29/2017 EXPIRES: 11/29/2018 Install synthetic underlayment, 30 squares Owens Corning Asphalt shingles I, by my signature, do hereby attest that the work to be performed shall comply with al] accompanying approved plans and specifications= applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this_permit. I further attest that � am legally authorized to include all entities named within this document as parties to the work to be performed Orf Aat all work tWbe performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief REQUESTS NUST BE Date FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of ,�/ Wheat Midge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: I ( / - �Ii /,I Plan/Permit # ­U�) 110 C) CA Plan Review Fee: Building Permit Application ** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: ash Property Owner (please print): G % /S j �Uy Phone7� z 1,C12 Property Owner Email: Mailing Address: (if different than property address) Address City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Phone: Contractor: F'1�iT� (/�' �.CA/!i fr Re6r4-�&_ Contractors City License #: Phone: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form 0 ❑ COMMERCIAL r_6�RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE EICOMMERCIAL ROOFING ❑ COMMERCIAL ADDITION `RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 1 �J mil +3 ( ✓� v fit -1/C c� Sq. FULF Amps Btu's Squares Gallons Other Project Value: ( ntr t val or the cost of all materials and labor included in the entire project) Ica, OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) SiEnature (first and last narnoza:��A��� DATE r / ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: DEPARTMENT USE ONLY OCCUPANCY CLASSIFICATION: Building Division Valuation: $ Building Permit Application Complete all information on BOTH sides of this form Property Address: llu)5 Sq� t.lLll ttu' Gallons Amps Squarer- Other Page 1 of 1 Kristy Shutto -7l0 W. ~ d- . ~ From: Kristy Shutto Sent: Monday, December 11, 2006 9:05 AM To: 'hhhmeistr@aol.com' Subject: Extension for permit #060417 We will grant at 180 day extension from 11/30/06. Your permit, #060417, will expire on 5/30/07. Please call us if you have any questions. Thank you, KriSLy 5hutto Permit Technician 303-235-2855 k5huttoC~a.wheatridge.co u5 12/11/2006 Page 1 of 1 Kristy Shutto From: hhhmeistr@aol.com Sent: Thursday, November 30, 2006 3:17 PM To: Kristy Shutto Kristy, Please accept this as a notice to extend permit 44060417 for an additional 6 months. Our detached garage has been constructed, but not dried in. I travel extensively with my job which has slowed progress. Thanks in advance in this matter and contact us if need be. Robin and Kelly Hofineister 7105 W. 29th Place 303-433-1681 G o~. ' ~~6v , r-xw . ~ ^i CheE ~ut the new AOL. Most comprehensive set of free safety and security tools, free access to millions of high-quality videos from across the web, free AOL Mail and more. o~~ O% '\o~ 12/4/2006 n O 3 N n S1 ~ C ~ ~ ~ C~ cD N 0 fQ a ~ ~ O n N ~ rr n fp O ~ 0 o rt O ~ 0-0 A N m Q 0 a M W c t~. ~ IC N 9 O ~ ❑-rn 0 (O Q a oo~ N !~1 N ZZ. o ~ Z O c> s a ~ . ~ oto O 5 = d ~ O/ N (D ~ m CL n 3 A m • O 0 S (o m S ~ N N n <D (D ~ ~ y ~ Q ~ 0_ c a z O M ~ ❑ V1 ~ 0 m N ~ 7C' N ~ c. -n O ~ 2 m T 0 r O z ~ ~ C ~ 0 C/) m r m^ U! D r O m C/) C~ ~ -u ~ O z -0 A 0 0 m ~ ~ D ~ 0 X m cf) N W ~ ~ ~ Y -u rn ~ Z m x O Z m ;J X 0 W Z 2 O T ~ m ~ ~ m A D ~ ~ ~ m Cl) U) ti 0 (Jl N ~ x ~ D^ l♦ m ~ m ~ O_ 3 N CD C ~ aQO~i a(D m m ~ ~ m a~ oco 3 m N m -0 s ~o~ ~ m ~ y ~ CD ~ C- c m - ~ N a m n~ ~ ~ ao ouN m 2 (D f ~ n Q o ~ a y n (D oo ~ -3 ~ n~ (D 3 * c m v N ~ N O ~ ~ * o ~ , m a ~ FD. ~ o a~ ~ a o~ 5 m cr (D W C C, (D a(0 , ~o cp N CD n o 0 n IDa(D -o Nm o 3 y 7 CD N to d ~ > > nQ o m S 1 N EF CD N N d a- 0 o m -u m 3 Z c 3 0, m ~ 0 co A CJ7 V C." 0 o0 =r m m co O ~ D ~ (D < CD 2 ~ ~ ~ ~ ~ ;u a v O (,j co m 0 O ~ w~ w m ~ O N 3 cr W I N ~ N O 0 a) n ~ ~ ~ ~ m ~ C) n n Z \ . .~~\^..nn.i`.:~'~'✓`.~i 1'L^.'~.^.'..\1.nJ'.~.~^.1^~'~/~,Ml~r'~~~:'J:niJ•.^:~!'l~VJ~n.'.'W'~Vl'/'./V~.iV~.'..~ ` Date: l A Certificate of Occupancy 1 Completion s has been requested for: ; ~ AonREss: w. ; PllRPOSE OF STRUCTURf: i ` ~ Building DepartmentApproval: : ~ Remarks: ~ ~ Zoning ApprovaL• 1N`- ~ Remarks: ~ . : ; Public Wor4cs Approyal: l z Remarks: ~ ; Fire Marshall Approval: ; (If Applicable) S Remarks:- S ~ ; Sanita4ion District Apprc ~ (If Applicabie) ` ftemarks: : i Water District Approval: ~ (If Applicable) 1 ~ Remarks: ~ ! S i > < ; ; ; Z ~ : : , 1 < : < ~ ; ! i ZS } ~ S } < ~ 1~ .WY~ INSPECTION RECORD 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 (303) 235-W55 cv-/nsaectfon Line (30~) 5g3,3 ln$Pe~ons wiil not be made unless this card 1s posted on the bullding site ?4 Hours notice required for inspections Job Address -7 ( ~ S W42-~+~tpl ivl Building Permit No. Date Issued ( 0 Type Occupancy OWner i / Contractor Contractor Address I .r~ I.IUo I oiUrv MLL JrAC;tS f ERTAINING f0 THIS JOB FWNDATION INSPEC770NS DATE APPROVAL DISAPPROVAL INSPECTOR COMMENTS: Footings/Caissons . INITIALS Stemwall ~ ReiMorcing or Monolithic Weatherproof / French Drain Water/Sewer Service Lines - - vcc~v VIUIVCV CONCRETE SLAB FIOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) ^ ~I V6Nice - v Vl.ll~ VIVIY CU RoughElectric R<wgh Plumbing Ai Test Gas Piping Rough MBchanical L~ _ • ; 4 Framing i, , • , ~s> 7-~ cNo, . , Ire Roofing Insulation . Drywall Screw I ~ FiNALs , EWcbical o - -OL Plumbin9 /O ~ -od Mechanical p - 2 -GG .dr~- Frame / Interior Finish R.O.W & Drainage FFe Department Parlcing & Larniscaping "NOTE: ADDITIONAL INSPECTIONS / COMMENTS ON BACK OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER w~ 03 wcl) N 7 W n A p ~ f~0 N W 21 0 7 N S < N cr (D N =3 3 a~ a m k\ N , o ~ ~ ~ y ~ 0 3 Gf .t C- 0 Q D a C A N N ~ (D n ~ 0 7 0 ~ ~ ~ ~ ~ (D n = on w N W ~ N ~ ~ N n 0 ~ C Z --I ~ ~m ~m ~ (D O .D vm C Z 0 0 ~m a ~ To Building Dept City of Wheat Ridge This formally requests an eartension of permit 19445 for an additional 180 days. Thank f~~ ~ r Robin Hofineister 7105 W 29b Place 04/26/06 09:52:21 City oE Whea[ Ridge bp701-1s PERMIT INFORMI+TION - 019445 PERMIT INFORMATION: Pennitk: 019445 PeTmit Cd: ResideR[ial Remodel Permit DC: 10/20/2005 Expires: 10/15/2006 Address: 7105 29ch P1 Paicel Cd: 39-264-09-005 OWNER: Robin Hafineisten Address: City/St/Zip: LAND PARCEL INFORMATION: Zone Cd: Residen[ial - Duplex DU: 0 FUIICC U6¢: [].db&igREd La9t ZonC DC: Subdivisim: Unassigned nnnex Dc Cont 'lYpe: Unassigned Lot: ffiock No: 0 Legal: JOB DESCRIPTION: Ex[end kitchen in[o single qaiage & add laundcy, & ba[h. In[e FEES QTY DUE PAIO: eermit Fee .00 181.10 181.10 Plan Review Fee .00 119.02 110.72 Total Valuation 7,000.00 .oo .00 ❑se Tax .00 126.00 126.00 429.82 424.82 CONTACTS: OWNER Robin HoEmeisCei 3034 331681 GC CLS HOME OWNER PEAMIT NOTES: 11/02/05 ADDTN SQ FT: 0 11/02/05 NOTIFY COUNTY 11/02/OS Ok w/ no[es. See copy oE city founda[ion s[andard F-1 attached 30/27/05 APPROVEO BY 10/27/2005 0:00:00 10/27/05 No expansion beyond existing walls. INSPECTION INFORMATION: p TYPE CONTRk CALLED CNCL WNO 1 FOT 12/02/05 no BM 2 exi 04/14/06 no bm 3 mii 04/14/06 no bm n pri 04/14/06 no bm 5 fzi 04/14/06 no bm 6 eri 04/19/06 no ua 7 pri 04/17/06 no BM REQ DT INS OT STATUS 12/02/05 12/02/05 C 04/17/06 04/19/06 i 04/17/06 09/19/06 c 04/17/06 04/17/06 i 04/17/06 04/17/06 i 04/18/06 04/10/06 04/18/06 C S N (D .n. O , o~ w(D N ~ w0 A o t~0 N W n W = . 0 7 N S SII N Q m m m 3 v Q m ~ ~ ~ N a (D C'! O 7 ~ C- 0 Q D a Q N N N ~ ~ 7 " r~~ L-i MN Mi (D 0 O3 i, r ~ ~ l J 0 N ~ ~ C CD 0 Z ffl~ ~ O ' v ~ m ~ m r 00 c~ .o vm Z N~ o' v ~m -o ~ w 0 ~ N W N N co N N r, F WHE4T City of Wheat Ridge ~OLoRa~° Res. Add Structure PERMIT - 060417 PERMIT NO: 060417 ' ISSUED: 05/26/2006 JOB ADDRESS: 7105 29TH PL EXPIRES: 11/26/2007 DESCRIPTION: 22'X 30' DETACHED GARAGE CONTACTS OWNER 303/433-1681 R& K HOFMEISTER OWNER 303/521-5071 PARCEL INFO USE: UA ZONE CODE: UA . BLOCK/LOT#: 0/ SUBDIVISION: UA ESTIMATED PROSECT VALUATION: 5,000.00 FEE SUMMARY FEES 144.70 Permit Fee Plan Review Fee 94.06 Total Valuation .00 90.00 Use Tax 328.76 TOTAL L7oCUit7CtltS ~ t e man ~ oc ction which specify Comments : onsite for fnal roof inspe t 22X30 FOOT DETACHED GARAGE roofing materials have been installed to mee 110 MPFI th►+ae-second wi►+d 8uat'" IBC Must meet 2003 zxc Must meet 2002 NEC I hereby certify that the setback d istances proposed by this permit applicaCion are accura[e, and do not violate applicable easemenes or restrictioas of record; that all rules or regulations of ordinancee the City of wheat Ridge or covenants, ree to abide by all conditions printed on this a nd d , own, an allegations meaeurements /~/y g a rea made are accurate; that I have ( for compliance with the Wheat Ridge Building Code I.H.C) and a11 other ili , application yJoaS~Faeume full L[ ! S/nrAinances, ty responsib for work under this permit. elans subject to field inspection. date Signatu e of contractor/owner the 1. This pexmit wae issued in accordance with the provisions set forth in your applicatCOlorado lorfiany e[he o r applicablef the State of Colorado and to the zoning Regulations and avilding Codes of wheat aidge, ordinances of the City. 2. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (Bi t e building authorized is suapended or abandoned for a period of 180 days. rovided no If thie permit expires, a new permit may be acquired for a fee of one-half the amount normally required, P has changes have been or will be made in the original plans and specifications and any suspension abfualnfees shallot exceeded one (1) year. If changes have been or if suspension or abandonmen[ exceeds one (1) year be paid for a new pezmit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage pro em. 5. Contractor ehall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive wtitten approval on inspection card before pzoceeding with successive phases of the job. 6. The ieauance of a permit or the approval of drawings and specifications shall not be construedlaw,brule ormregslatioo an aPpnoval Of, any ~'a n ons of the building codes or any other o=dinance, All lan review 'ec o field in 'ons. ~ Si nature of ief Bui ding Of ical date 9 IN3PECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR ZNSPECTION THE FOLLOWING BUSINESS DAY. oF WHEAl City of Wheat Ridge Building Permit Number: ~ m Community Development Department Date: COLORPO~ ~ 4.~~.f.\"V~/ ~'j,LlrD T~6~ FAL6'.~1IL Y p C1 .A;~~ ILDLNl.E PliRM4. ~~PPLR. CA 4 .l. ON Phone: 303 `f33 I b8f g Property Owner: (1p&1J-t1; F ODRt' Property Address: 7(OS tA/ 2" PL • Conh'actor License No.: ~ Company: ~ Phone: '3D3'5Zr.507/ C OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Buildina Dept. Valuation Figure: $ I hereby certify that the setback distances proposed by this permit application are accurete, and do not violate applicable ordinances, rules or regulations of ihe City of W heat Ridge or covenants, easements or resirictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliancewith the Wheat Ridge Building Code (I.B.C) and all otherapplicable Wheat Ridge Ordinances, for work under t is permi . Plans subject to field inspection. s~s-~ (OWNER)(CONTR4CTOR):PRINTED DATE Value:$ 5 000, 00 Permit Fee:$ Plan Review Fee:$ se Tax: Totai:$ Use of Space (description): / Description of work: &u,ld 2Z , x 3a ' Plr 6AGgot~ Sq. Ft. added W BUILDING DEPARTMENT USE ONLY COMMENTS: rf Na W~'6 E7 -07 Approval: J~{ G•0 6' CR Zoning: A_Z - COMMENTS: Approval: WORKS COMMENTS: Approval: DEPARTMENT COMMENTS: Approval: Electrical License No: Company: R ~ MqFc~~~F K O <OV~ ~i Walls: Roof: Stories: Residential Units: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Expiration Date: Expiration Date: ApprovaP ApprovaP Approval: (1) This permit was issued in accordance with ihe provisions set forth in your appliwtion and is subject to the laws of the State of Colorado and to the Zoning Regulations and Bullding Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permii shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of'I80 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been orwill be made in the original plans and specifications and any suspension or abandonmenl has notexceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contraclor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and snall receive written approval on inspection card before proceeding with successive phases of the job. (6) T 'ssuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an rovalof, nyvolationoftheprovisionsofthebuildingcodesoranyotherordinance,law,ruleorregulalion.Allplanreview 6ject fi d i ections. lb'r Chief Building Official Legal Description Provided by CusWmer lOT 12 PALMYRA PARK SUBDIVISION COUNTY OF JEFFERSON STATE OF COLORADO 9I.68' _Q 5' .ESMT. ~o - ~ LOT I I I LOT 12 ~ ~ ; -U-, 6.2"' ' ~6.8" ° 21.1 ENCLOSED 1 w rZ , cc FI 207 u7105 ~ b> w 29-6 I STORY M ~ `n i~ BRICK M m #7135 N ~ 4.4' I 3. N N ~ ~ 15.0' o f-i ,l i COVIui~ 17.1. w > ~ 0 91.68' WEST 29TH PLACE COLUMBINE SURVEYING, INC. NO TA 7573 South Ames Way Littleton, CO 80728 (303) 972-8000 IMPROVEMENT LOCATION CERTIFICATE scale r"= 2' I hereby.cettify thffi this improvement bcation cert'rf'~caae wes.pMpgred tor. JUPI7ER MOI270AGE CORP(YRATION that Il le not a land eurvey plal or ImprooemeM survey plat, and ih8l It is not M be relfed upon for the eStablishmeM of fence, building, or oNer future imprrnementlines. . . . I Nrlhet ceNy thet ifie Improvemenb on tlie above described parcei, eucept Wilry connecGons, ire enthey wilhin the boundaries of the pamxl, except as ahown, thet there arc rw enCroeMmBnta upon Me descri6etl premisea Dy Improeements on any gdJoininp prEfnises,.ewcept as Indiwted, and that there is no apparent eNdence W sipn of ny eoBemem crossing or burdeninp any part M said parcel, excepi noletl. Notte: AtmdMn91o Calxe7o Mx pu mW commenue eny kgal aclpn Eesed upon anydoecl NOTE: All pletteil iM apperent ees6menis are shown. RetorE easements, if m b(s inqroyanmd bcalion tertiflCel9 wilhin IAre9 yeas afier you frst tliscovwed sucA defect eny, are located by informatiun.pmvided by the customer, unless otherwiae In m ~l, mey eny aclbn bmed upon erydelect m Ihis Improrement bcalbn ceAifpBla pe noted. ~..,.r commencetl imre fhen ten yearo Irdn th8 tlata of th9 certiACate shown hereon. ~c-C 1 ~ f r 17 > i~(~ ' . le S~✓-~ . 9uyer : VALDEZ/PAZ Michaei A Fvan6ks L:-.111191 Address : 7105 W. 29TH PL. Professj onalk'-aq.37~ ~g rv'eXpr, Title Co : Order : 31000083 p~~'• ,~<;r( i , di a/o2 m Chapter of the International How to Use this 6uide Provide two sets of plans and complete the following: 1 Complete this Building 6uide by filling in the blanks on page two and three, and indicating which construction details will be used. 2 Provide 2 Plot Plans (site plan) showing dimensions of your project or addition and its relationship to existing buildings or structures on the property and the distance to existing property lines, drawn to scale. 3 FII out a building permit application. The majority of permit applications are processed with little delay. The submitted documents will help determine if the project is in compliance with building safety codes, zoning ordinances and other applicable laws. The Colorado Chapter of the Intemational Code Council is a professional organization seeking to promote The puWic health, safety and welfare to building ' constniction. We appreciaie your feedbadc and suggestions. To obtain a master copy of this building guide, please write to the Cobrado Chapter d the Intemational Code Council, P.O. Box 961, Arvada, C080001. This handout was developed by the Colorado Chapter of the International Code Council as a basic plan submittal under the 2000 International Residential Code. It is not intended ta cover all circumstances. Check with your Department of Building Safety for additional requirements. City o 'Wheat ~(jQ'ge o~ w~cq, Bung ~Division "o TSOO 1N ?9i° f7ve. - m 4Vheat ~,uCge, CO 80033 (303)Z35-?855 ~o:oq~oo 11I Direcdons 1. Fill in the blanks on pages 2 and 3 with dunensions and materials which will be used to build the structuie. Please print legibly. 2. Indicate in the check boxes on page 3 which detail from page 4 will be used. Note: Heated garages may reguire special psovisions. Dimension 22 ' Lxate and Indicate ra(ter or detail bracing , . truss direction O,Garage is heated e7 Garage is not heated Show door and window header sizes and location and size of landing in iront of door N FlP°e Di 3m0ension ~3'/i minimum concrete slab Z x td_ header J~vis: (2) z, io 1 Note: If roof trusses or rafters bear on header, special header design may be required Double 2x4 or 2x6 trimmers each ~ end of overhead door header - Garage door opening Garage door opening width / 8, ~ i DimenSion' 2 " 2' 8" minimum, with plywood sheathing on outside of entire wall D'u[tension' Z with hold downs. I( less ihan 2' 8", engineering may be required. - This handout was devdoped by ttie Cobrado Chapter ot the International Code Council as a basic plan submilfal under the 2000 Intemational Residential Code. It is not intended to cover all circumstances. Check with your Deper6nent of Building Satery for addrtanal requirements. rri Minimum lx_ridge board of covering h~~ G~ 5~/~ s leremde: 7 x 721 111 Ro (e~mple: Ckss A 31eb shirrg/es/ J . itch _ ~ 12X 2 ~ lid eiling Insulation Provide roof tie downs and so ~n~t~_ a„ma, q_~) 2x blocking between rafters (2x12 or greater) cei ling jouu @ ~O.C. (e.~mpe:2,aee4 - o.c.) ~ Double 2x top plate - - - - ' (example: 2 x 6) LSpan 22 ' ~exemp1e:23' 5') Note: Pre-engineered roof husses ~ wftruss clips and hardened nails may be Ceiling height ~ used in lieu of roof shucture shown. „r,,,,la: e1 Diagonal wind bracing a plywood shear panels I Siding L~. -JLJ @ comers and each 25' of walL (eramde: wp w ri I t) Wall ' , ...F aX_~( -stuas @ O.C. (BxemWe:2x602d'O.C.) Cont. 2x ~ sill plate : B (exempb: 2 x 8J rf, Wall Insulation ' (tl heeted ~ erartple: fl-19 Fibe~glesa BettsJ Foundation Detail A ❑ foundation Detail B (see page a) Footing size x (BSemua: B' X tB~ This handout was developed by the Cdorado Chapter of ihe Internetionai Code Council as a basic plan submiltal under the 2000 International Residential Code. It is not intended to cover au circumsiances. Check with your Department of 8uilding Safety for additbnal requirements. Note: For roofs with slopes between 2:12•4:12, follow manufacturer's instrustions for low slope application of roofing material. Truss or 2x_rafters spaced Z4" O.C. Sheathing , 2 ~example:'R' ealenorplywaotl) le,,mp/e: Put checkmeAin Dar orv 2 x f 0 FeRers Speced 24' O.C.) ~ ~ oJ :r ~a IV ~ ~ ~ ~ ~ ~ p N ~V M t l~ b M O b O x • F ~ ~ 0 u C N ~ ~ R 4 ~ . e~, r~~ ^4fk~ ~Y.NO'k'Y?+Y.TE P~v.~~ R*AK"YW~&W + Building Permit C1TY OF WHEAT RIDGE 7500 Weet 29TH Avenue Wheatridgq CO 80033 303-235-2855 li~ rarorvrt,~raace k~ Permit Number 19445 r F r :y p ~ Residential Remodel 11/2/2005 Inspection Line 303-234-5933 PROPERTY 7105 29th PI Unit: owNER: Robin Hofineister (303) 433-1681 Description Extend kitchen into single garage & add laundry & bath. Interior remodel Units: Occupancy: Walls: Roof: Stories: SqFeet: `C ! 0 I hpsbY mh' tbat Ne nlbad dbtaoca proporzd bY thls psmlt applicatlon ore secuntq and do vot vblate apPitmbk oNivmea, rvln or reeehEOm of We City of . Wyeat BWpar wvauob, enemeob or mhlcllom of reaord; Wt W mwuremeob ehawn, mtl aikeoUOns mmtle an sauntq tbaf I M1rve rad uiA aCrent^ a61de by ~p wulltlop~ pd ed o applly~~ and Ou[ I.uume fWl reDOVWNty for compliance xith the Wheit Ridee Bu0tllne CoOe (1..B.C.) and J otCer appllubk . g'pa~t{IIE[r~tor oEu atnbvermit. uvv_.--rv4A413_,CONTRAGTOlk) SIGNmDATB I 7'Ws.peMl wu beeed In s«ordanee witb Ne provbboe u[ (orlh in your opplieatlan and tr sub)eat to tAe Iaws of the Stae of CobvAO *ed a Ne TndeC Aqdatlow aetl BuiIEWL C^de of Whot RIEgq Cobnao or any o[ha applicabk ordimom of tAe City. 2 &very permit IuuM tWII berome invtlid mkae We nork on Ns sim autborluN by such pemic b commenced weNin 180 Aays ~fler Ib ivwva, or IfMe worl, mt4odzd eo tEe dte by meh pennlt 6 mspeodW or abaodoncd 4r a period of 180 days after ILe fime of work b commenced. ) ((dpy psdmtl ezp4n, a vew permit eory be uquUed for a fa otono-h.V Ne amount norma% requlnd, pmNEed oo chmpa hrve bae or MY Ee wde In ehe oA'ladplan md ~pallkmtbo, and Doy awpenJOe or ~bmEOmmmt hn oot exeadM one (1) yev. if chmea erc euEe or IOuepuuloo or Waotlonmrnt . auseds one (1) rev, fuil Ro+hall be p+id for . nm permit. 4 Iio werk ofaoy m.onenholl be done tha[ rN ahante the nuNnl lbw of wmer caminy a dnina¢e Drobkm. ~ Covtrufar tlatl votlty the BWMin{ Ivapector twmty-four (20) houn lo aavmtt far dl lmpeetioos mtl eball recelve wtlnm .ppmval oe WryeeHan cW beton yroroWlnt wIW ~uttaNVe pAUa otthe job. ..6 tle iqwa of~ e~pPr^". =pKlOcatioouAall not be mmtrvM to be apermitfaq nor mapprovl of, my vloi~tloo of We pwvbbo~of n oNerordlou~ce,la korregulotbn. Wednesday, November 02, 2005 Page 1 of 1 ~ ~ N 7 w0 ~ A O i ~ w~ c i W O ~ `V 7 3 (D O ~ ~ 6 m m :3 3 m Q -(D ~ 0 ~ N N ~ a m 0 = ~ ~ 4) C- 0 c D a a a N ~ n 'Z ~ n ~ O:3 II 1-~, L~ Ml~ n (D 5 N 'a (D f~ ffl~ 0 n cn m :Z, 0 (D Cl) v O ~ W 0 ~ N W N N ~ N cn Q ~ ~ C Z -i v rn m r ~ m Z ~ m ~ ~ Building Permit CITY OF WHEAT RIDGE 7500 West 29TH Avenue ~ Wheah-idge, CO 80033 303-235-2855 Residential Remodel Permit Number 19445 11 /2/2005 Inspection Line 303-234-5933 PROPERTY 7105 29th PI unit: owNEx: Robin Hofineister (303) 433-1681 Descrip[ion Extend kitchen into single garage & add laundry & bath. Interior remodel Authorized By guilding Approval Authorized On Zoning Approved By Ok w/ notes. See copy of city foundation standard F-1 attached Authorized By Zoning Approval Zoning R-2 Authorized On 10/27/2005 Approved By MR No expansion beyond existing walls. Wednesday, November 02, 2005 Page 1 of 1 COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: oF w"E'°r,~ BUILDING INSPECTION LINE - 303-234-5933 Date: ~ g CITY OF WHEAT RIDGE " 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) ~~~oRPa~ APPI.TeA77C11V Property Owner: ?Gb1v rF 0 FMV tS TLY4 Properry Address: 71 oj w 2y Y~ ~L Phone: 303 ~33 I(~ E( Contractor License No.: pany: Phone: 3 S~' re L~~ Com OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT Buildina Deat. Va/uation Figu.re: $ I hereby certify that the setback distances proposed by this permit appliration are accurate, and do not violate applicable ordinances, rules or regulations of the City of W heat Rid9e or covenants, easements or restrictlons of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the W heat Ridge Building Code (I.B.C) and all other applicable W heat Ridge Ordinances, tor work under lhis permit. Plans subject to feld inspection. (O W NER)(CONTRACTOR): (OWNER)(CONTRACTOR):PRINTED DATE Value:$ Permit Fee:$ Plan Review Fee:$ e Tax: Total:$ %7, uco Use of Space (description): Description of work: ~~C'~2K K~ic(tPC{ i v64o G Sq. Ft. added (VL4e✓kJJ' V't ✓bl0 d COMMENTS: Approval: Zoning: C\ \1 rJ ~ ti (J~ G COMMENTS Approval: ~ Pl1BLIC WORKS COMMENTS: Approval: )RE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Electrical License No: Company: crl Roof: USE ONLY 1 - ~ 6_ « ~ , SIC: Sq.Ft.: cc~~ Stories: Plumbing License No: Company: Mechanical License No: Company: Expiration Date: Expiration Date: Expiration Date: Approval: Approval: Approval: (1) This permit was issued in accordance wiN lhe provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of ihe Ciry. (2) This permit shall expire if (A) the work authonzed is not commenced within sixty (90) days from issue date or (B) Ne building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the onginal plans and specifcations and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid fora new permit. (4) No work of any manner shall be done that will change the naturel flow of water causing a drainage problem. (5) Contractor shall notity the Building Inspector hventy-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a permit or the approval of drawings and specifcations shall not be construed to be a permit for, nor an approvalof,anyviolatio ftheprovlslonsofthebuildingcodesoranyotharordinance,law,ruleorregulation.Allplanreview is subje in ctlons. ief Building Official Residential Units: Z~ ~ Y~I BuildingPermit CITY OF WHEATRIDGE 7500 West 291T-I Avenue Wheatridge, CO 80033 303-235-2855 cnydvmexradge_ ~ Residential Electric Permi[ Number 18783 5/31/2005 Inspection Line 303-234-5933 PROPERTY 7105 29th pl ULLIt: OWNER: CIlY1S Va1C18S (720) 220-7912 Description Up grade elecfric service to 125 amp. FEES_ ~CONTRACTORS _ IName _ _License # N.S.E. INC. NIETO AND 20913 - jAUTHORIZATIONS ETYpe ]Notes - _ - LwldingApproval-__ ~ . _ - ~ _ _ 'Approyed - _ _ _ - Unifs: Occupancy: r-3 Walls: RooL• Stories: Sq Feet: 0 I Acreby eerlify chal the xtback d'ulanas propoasd by tM1ia permll apptintion arc aacuralq antl do nol vblcte appllaabk oNimmtta, rvlq or neWUlans of the City of Whevt Ridge or rovenmts, euemems or reetrieHOns of reooN; lhoc all meosuremmb ehoxn, ind tlke+llone mnJe are nccuotr, tAa, I M1ave reaa antl ayee m vbide Ly nll condiHOns prlnhd on Ihis applitalioq nnd Ihat Iaasume PoII respomibility for rompllma wllh the WFeaf Ridge BuilJing Code (U.B.C.) md .11 other .pplienble WAe t Ritlgeordinance;forworkunde [h' perjmi. /~z,~- L ~ r~ _ .__4~- 6'~ (OW YER)(CANTRACiOR) ' 61GNED DA'!E 1 ThispennitwasissuedinaceordancewitM1lheprovisionseclforthinyourappllcrtionandissubjealtolM1ehwsoftM1eSbteafColoradoandfofheZaoing Regulmionr anA euilding Cade af Wheat Ride<, folonJO or any olher appticable artllnances of the City. S This pemit shell expire if(A) the work au0orized is not rommeneN wichin aixty (60) tlays from iuue datt or (8) the bu0tling rvthorittd b auspmdeJ or .bvndoned far a periad af 120 daya. 3 If this yennit expires, v new parmil mny be ocquired for a fse of one-half iM1e amaunt normally rtqu'v¢d, pmvlJed na cM1ango have been or wN be made in the original phro nnd specificationa anA any euspenslon or abmdonmenl M1u me exceeJM ane (q ywrJlchanges m meJe or if suepcneion or abmJOnmmt ezceeda one (I) Ynr, full fees shall be paid (or x new permit. 1 No wur4 of nny mnnner sM1all be done tM1at will ohmpe lM1e natural lbw of water aausing a draiuage pmblem. 5 Convoamr shdl notify the Building Inspxmr ewenty-faur (14) M1oun In aJVOnce for all inspettiom mJ ehtll rereive wntten approval on Inspmfion nrd before pronetling wi1M1 mccueirc pM1Up of tM1e Job. b The ivuvna oh permit or the vpprovnl of anwinga md fpeai6caglans 9haH mt be com[med lo Le a yermit for, nor m npprovnl o(, sny vloblbn of the provtvionsafthe odevoran o rortlinnnce, orreguWtion. - - - Phone ] - - - 4350557 I 7'uesday, May 31, 2005 1 Page 1 of 1 COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Number: o~ W~E~l,p BUILDING tNSPECTION UNE - 303-234-5933 Date: ~ o CITY OF WHEAT RIDGE " ^ 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) APPLICATION Property Owner: C E4 IZ. I S LN~3 Property Address: r7 I OS w Z9 A el Phone: ~ ZO -2 20 Contractor Licente No.: N?,nyany A, TYt Pbooe: 3 0 3- 7io OWNER/CONTRP.CTOR SICNATURE OF UNOERSTANDING ANO AGREEMENT I BuiJdino Dept Valuation Figute: $ I hereby certify that the utbadc distances Droposed by this pertnit application are accurete, and do not violau applipble adinances, rules a repuWtions o( the City of W heat Ridge a covenants, easement5 a restrictions of record: Ciat aN meawrements shown, and aNeyaUOns made are accurate: Mal I luve read and agree b abide by all condiGOns printed on Mia application and thai I assume full responsibiNty (or compliance witti ihe W heat RiCye 8uilding CoOe (I.B.C) and all other applicable W heat Ridge Ordinances, for work uMer Mis pertnil. Plans subject W fie10 inspection. IOWNERMGONTiUGTORI:SIGNEO L, A) DATEJ Q (OWNER)(CONTRACTOR):PRIHiED DAif Value:$ Permit Fee:$ Plan Review Fee:$ UsTot l:$ Use of Space (description): Desc ~ion of_ worlc,C p Sq. Ft. adMd COAWENTS: ApprOVal: Zoning: Caar.Er+rS: AAProval: W onl(5 COrAWM5: Approval: BUILDING DEPARTMEIVT USE ONLY DEPMTMEM COMMENTS: AppfOVHI: Watis: Roof: Stories: Residential Units: Fl.: E1ecVicai License No: Plumbing License No: Mechanical License No: Company. Company: Company. Expirafan Date: Expiration Date: Expiration Date: qpprovyl: Approval: Approval: (1) This permit was issued in accadance wilh the provisiona set foM in your appliption and is suDject b IM laws of Vie SUte of Cobrado and to tlro Zanirg Reyulations and BuilOirg CoOea W Wheat Ridpe, CobraOO a arry oCm applicabb adinances of Ihe City. (2) T1+is permit shatl expiro N(A) the worle auborized'u ral oommencetl wMhin sixry (90) days hom issue date or (B) the building aWMrized is wapaWsd a abandone0 fa a period o(180 Eays. (3) If Nis pennN expirea. a new permd may be acyuireC ta a fee M one-haM tne amouM normaly mpuiro0, povideG ra dhanges have Deen w will be rtiWe in iM aipinal plana and spedfioUOns and arry wapensbn a aDandonmeM has nol exceeded one l+> rear. n awnyea nave eeen a if wapensia, «abandombnt exceeAs one (1) rear. mu rees snau oe wd rw a new ve+mil (a) No woAC of any manner shaY be done that witl dwge the na0ural fbw ot wabr ouafnp a drainape probbm. (5) Contracbr slw6 raHly ths BuYdvq Inapecfor twerrtY-far (24) lauia in ad+anos fa ap mspections an0 shall receive wririan spprevy on 4upeetlon rard befora Drocee0in0 wiM sucoeaivs Phases of tlis job. (6) The iasuanee of ! Pe^^K a tlm epproval ot drawin7s arW specffipdons shaM not Oe constnieC to De a Oermrt /or. nor an apprwal of. anY violadon of the Drovisione M tM bu'ASinp codes a xry other ordirranx, law, rub a repuWtlm. NI plan rsvMw b suDJect to MW InspocWns. Chief Building Official PERMRNUYlER 95-1206 a 3 $ 0 0 ~ 3 ~ ~ a m o y c a a I > > m o ~ 0 ~ Z 0 n m mm mm o o~ ~g 0 01 3 ' m m ~ n o m 3 ~ ~m m c n m ~ o 0 ~ w m c v a n ~ om mf 0 a O 0 0 m ~ a m E O 9 1 x m O r O ~ Z G) v c 9 8 m D 9 r m o I m 7~o O ~ m O y 2 tn v 0 ~ ~ N ~ ~ X 'U ~ w n CD 8 1 ~Y 9 O D o a ~ c Z $ m s F o m°a ~ a m ~m r W 2R Dm~ m m ~ m mc~ w ommm c ~ rt »m ° :3' m~m~ ~ ~ ~ s.. y ~mm~ ~ vpm m 0'3u n ~^c 0m~ ~ n tl > ~°g° m s n ~ r°mn~ nf o S. n~_ 0 m $~o ~ ° 1.~1 m w m ~ D a m ~ J n;t 0 0~ 9 C) c m °v mm°m ~ m ~ ~ m ~ Y ng m ci i i m n o mmo I'd O U O > ~ 3F~ C) ~o~ o z ~ F aE; m ao Q N ~3s v n ~ ~ ~ N m~ ~ ~ fo rt m r n ~m~ H N N ' -c ~ : N - , DATE: O A CERTIFICATE OF OCCUPANCY HAS BEEN REQtJESTED FOR: -2/0 5 CJ o? PURPOSE OF 8uild"ing Dept. approval: Remarks: C4r% Zoning 8pproval: Sk--- Remarks: _ INSPECTIONS WILL NOT BE MADE UNLESS ~ THIS CARD IS POSTED ON THE BUILDING SITE 24 HOURS NOTICE REQUIRED FOR INSPECTIONS WHEAT RIDGE, COLORADO 7500 WEST 29th AVENUE INS P ECTI O N R ECO R D►303) 234-5933 IOBAI~fuRESS7105 W. 29th Place BUILDINGPERMITqO. 95-1206 DATEISSUED 6/14/95 OWNER Goldie Barth CONTRACTOR Mike CriQ]er SETBACKS AtOM PROPERTY IINES: NORTH SOUTH EAST TYPE OCCUPANCY West INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB I NSPECTION DATE I NSPECTOR Foundations Footin s p.~ 5' ~ ( Caissons Reinforcin or Monolithic v. - G, Weather roofin POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED Concrete Siab Floor: Electrical Ground Work Plumbin Ground Work Heatin Ground Work DO NOT POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED Rou h Electrical Rou h Plumbin AirTestGasPi in Rou h Heatin & Ventilation (above must be signed prior to iraminp inspection) Framin Insulation Dr wall nailin Roofin Refri eration Electrical under round Final Electrical Fixtures Plumbin Fixtures Heatin 8 Ventilation , Landsca e & Parkin R.O.W.R Draina e Fire De artment ~ y Job Com leted OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER DEPARTMENT OF PLANNING AND DEVELOPMENT BUILDING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 Building Permit Number: 95-1206 Date :6/14/95 Property Owner: BARTH GOLDIE W Property Address : 7105 29TH PL Contractor License No. : 17856 Company : Mike Crigler Phone : 237-8245 Phone: 340 5770 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or wvenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application, and that I assume full responsibilr for compliance with the Wheat Ridge Building Code (U.B.C.) and all other applicable heat idge ordinances, for work under this permit. (OWNER)(CONTRACTOR) SIGNED ~~J DATE Description : GREENHOUSE ADD TION TO EXISTING HOUSE Electrical License No : `Plumbing License No : Mechanical License No : Company t,j'ii?,~ Company : Company : Expiration Date : Approval: a Expiration Date : Approval : 29r Construction Value : $9,000.00 Permit Fee : $108.00 Use Tax : $135.00 Total: $243.00 Expiration Date : Approval: ma (1) This pertnit was issued in accordance with the provisions set forth in yopur application and is sub'ect to the laws o/ the State ot Coloredo and to the Zoning Regulations and Building Code of Wheat Ridge, Coloredo or any other applicaGle ortlinances of [~e City. (2) This permit shall expire if (A) the work authonze0 is not commenced within SixTj (60) days from issue tlate or (B) ihe building authonzetl is suspended or abandoned for a period of 720 days. (3) If this permit expires, a new permit may be acquired !or a fee of one-half [he amount normally required, provided no changes have been or will be made in the onginal plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abantlonment exceetls one (i) year, full fees shall be paid for a new permit. (4) No work of any manner shall be done that will change the naturel Flow otwater causing a drainage proClem. (5) Contrector shall notify the Building Inspedor tventy-four (24) hours in advance for all inspeclions and shall receive written approval on inspection card before proceetliing with successive phases o! Ihe job. (6) The issuancey permit or the approval ot drawings and specifcations shall not be construetl to be a permit for, nor an approval of, any violalion of ihe provisions of the builtli g tles or ny other ordinanc , law, rule or regulation. ~j~. Chief Oilding Inspector THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION DEPARTMENT OF PLANNING AND DEVELOPMENT Buiiding Permit Number : BUILnING INSPECTION DIVISION - 235-2855 CITY OF WHEAT RIDGE Date : s-3 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80215 PropertyOwner: ~~~~if- PropertyAddress: ~t~~j ~ LatN ~,Jtk~A~¢4p~~GO. Phone: Z3Z-$Z4S Contractor License No. : µ ike, Ga-tq&4~--q- Company: ,7 W5~ Phone: 3c.(-o.S-776) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hemby certify that the setbadc tlistanees proposetl by this permrt appheation are accurate. and tlo not vlalate appliwble ominances. rules or regulaBOns of the Ciry af Whea[ Ridga or covenants. easements or restnetions of reeortl: that all measurements shown, antl allegations matle are accurete: that I have rcad antl agrce to abitle by all condRions pnnted on this appUCatwn, anc that 1 assume full responsibility for eomphance with the Wheat Ridge Builtling Code (U.B.C.) ana all other applieable Wheat Ritlge ortlmances. krwork under this pertnit. (OWNER)(CONTRACTOR) SIGNED 7 YM/~'JJ,DATE near.rmtinn Construction Value : ; cyy) . Pertnit Fee : ~ p 8.CY-d Use Tax : ~ 3 S- c"" Total : a c.1 3 Q-C) T~ t-X iS i i t vi!'[ (.~-o uSE BUILDING DEPARTMENT USE ONLY ~af Approval Zoning : 2-2 eewau~~=cam-m Approval : Pq61~~Wb1'k~s-~Ebinmsnts:! Approval Occupancy : Walls : Roof : Stories : Residential Units : Electrical License No : Plumbing License No : MechaNcal License No : Company Company ; Company : Expiretion Date : Expiration Date : Expiration Date : Approval: Approval: Approval: ~ ;~P,18ris ftf9utred.= ~ Fl,hs Re'~uL'ed:7 (1) This permit wae issueE in a¢OrOanCe wiN the provisiona Set forM in yopur epplice0on anC is suDjecl to the laws of the Stete of Cola2tlo entl t0 Ne Zoning Regulamns antl Builtlmg Cotle of VJheat Ritlge, Cc',ora0a or arry oNer applicable ominantea of the Ciry. (2) This permrt Shall expirc rt (A) the vrorK auNOn2etl is not tAmmenceu witlim sicly (60) tlaya hom is5ue tlate or (B) the huiltling auNOnZeG is su8pentletl a abantlonta for a penoG af 120 tlays. (3) It mis permn ezpiros. a new xrmit may oe acpwrea for a fee of ono-hatt the artwunt normalry required, proviaed no Uanges nave Deen or will oe meds in the ongmal Olane antl apecificaGOns anO any suapension or aDantlanmeM has not ezoee0e0 one (1) yeac If changes em matle w if suspennon or abantlonmeM eXCee75 One (1) yeac full kn ehell De paitl fOf a new oermh. (4) No worK o1 any manner snall bE tlone Nat will Ulanae Ne natu2l IIOw of water Wusing a arainage proolem. (5) Contrdaor shall nobry the Bwltling Insoector hvenry-rour (24) hours in aavance /or ai1 insDectlons antl shall recerve wntten approval on mspeclion Cam ONoro p ung wrth successrve pnases ot the pb. (6) T 1 suan of a Demmt or tne appmval o( tlrawmgs antl speufirations shall not be mnstruetl to Oe a pertn@ lor, nor an approval of. any violaGan of Ne pronsrons ( 1~ i~ g co des or any oth ardmance, law, ru,e or reguiauon. hief Building Inspector For Mayor THIS PERMIT VAI.ID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR CALL: 234-5933 24 HOURS PRIOR TO INSPECTION Recerded at........ o~f d'clock M... . Recorder. Rdception No......._--...._ . fiHI9 D$E1I, Made this 3! hVday of Octnber ,19 Flt.fgG 9TAMP ~ between mo c n C70 r-r.,~..~ y PS. i'LqRF.N(;14 P!~JRP. za o --i n:: - C ° ym ~ m m . <O _ . . rW ~ ~ of the County of ,TEFFEXSCAT and State of Colorado, of the first part, and + ~ " ~ ' U 'dU.LIAM E'1. 5APTP 1.0 cnt')ri! 11. PAC:rN ' O , of the County of P'rFrT`OT'! and State ~ ' t7 ~.j U of ColoraQo, of the second part: WITNESSET$, that the said party of the firat part, for and in consideration of the aum of EIGETTEEN TAOUSAPdD P'IVF 11IJ1TF)rrp .417n LIO/lnf) DOLLARS and other good and valuable considerations to the said patty of the first part in hand paid 6y tlie said partiea of tha second part, the receipt whereof ie hereby confessed and aeknowledged, has granted, bargained, sold and conveyed, and b9 these preaents does grant, bargain, sell, convey and confirm unto the said parties of second part, their heirs and ass9gna forever, mot in tenancy in common but in joint tenancy, all the following described lot^ or parcels of ]and, situste, 19ing and being in the County of J^ `(e•,^,.:)n and Stste of Colorado, to-wit: Lnt 12. rnr,ltYR~ rA^,r 0iJRpin71.!mpi rnrnt,-. of Jeffe,-=„n. c•aC.P .,r L•,1o-adc,, . P,~!.~¢ il(15 I,rrgf ~3tf! ^Ia.CE. t.~~io•...~.q~~ !.,.~l.n...t,~,., TOGETHER with all and aingular the herediWments and nppurtenances thereunto belonging, or in anywise appertaining and the reveraion and reversions, remainder and remaindera, rents, iasues and profita thexeof; and all the estate, right, title, interest, claim and demand whatsoever of the esid party of the first part, either in law or equity, of, In and to the above bargained premises, with the hereditaments and appurtenanees. TO HAVE AND TO HOLD the eaid premises above bargained and described, with the appvrtenances, unto the eaid pArttea of the second part, their heire and assigns forever. And the eaid part9 of the first part, for himaelf, his heir9, execators, and adminiatratora, does eovenant, grant, bargain and agree to and with the seid partiea of the second patt, their heirs and assigns, that at the time of the eneealing and delivery of these presents, he ia well seized of the premises above conveyed, as of good, sure, perfect, absolute and indefeasible estate of inheritance, in law, in fee aimple, and has good right, full power nnd ]awful authority to grant, bargain, sell and convey the same in manner and form aforesaid, and that the same are free and clear from all former and other grants, bargains, salea, liena, taxes, esseasments and incumbrancea of whatever kind ornature soever, nn!- 1"! ^:ir0 ^,+h-nnuer4Q taxes, re^,Crir;;.enF, re^er.,~ti~~vs *;ahts of nn-l if any and the above bargained premises in the quiet and peaceable poasession of the said paxties of the second pxrt, the avrvivor of them, their asaigna and the heirs and assigns of such aurvivor, against all and every person or persons lgwfully claiming or to claim the whole or any part thereof, the said paxt9 of the first part shall and will WARRANT AND FOREVER DEFEND. The singalar number ahall include the plural, the plural the singular, and the use of any gehder ehali be applicable to all gendera. IN WITNES3 W$EREOF the said party of the firat part has hereunto set hia hand and seal the day and year flret above written. Sf ed, Sealed and Delivered in the Fresence of ~ ~.L((.. '-~yd gr` 2.GZe[SEAL] i.f. 111i(+o [SEAL] [SEAL] STATF, OF COLORADO, 1 } ss. County of ,I?PFE7,90PI J The fotegoing instrument was acknowledged before me this "rl' day of bS" M. I'L,O.^,Ertrr? piCien My Comm3saion ezpires TT'''''h ?S ~ 19 Wrtness m9 ha rl~ . 1 .p~ 7 ] v~ ..-k p va, WARRANT4 DEF.D.-To Joint Tenante.--Rrndford-Robineov Pdnting Comnany, I829-46 Stout Street, ~ NO. 921A. •If by natural pereon or yereone here Inaert name or namea; if by Derson acting in representatlve or ol attorney-In-fact, then lnsert name of Dernon as ezecutor, at[orney-In-Yact oi other capacity or descriDtlon; netlon then Inaert name of euch offlcer or offlcere, ea the preaidmt or other ofticere of euch r,•~~•~ratlon, n ttowtedpmext,_ Sec._ 118-8-I Cotorado Revieed Btatntes. 19h3.. . . _'`InrP.7 M n n . Terfifiexte nf ~IuprnUetncnf ~urGeg Wm.11.6urq.in R Asmcialee,INC. Cansullin9 EnAinoars na oeuwnnc sr .wan cooe ooo. x:a.veav oiuvrn. wioneeo eoxw S' Eesement h Lo/ iZ ~---;zc `IL_ Can<. ns' ei. B' S6GvE~J^~ n ~/OS q z .a.' One $/e y ~ MG. e Rar.denc e zs• q ' f , 93 I 0 I ~ V q v N ~ z s. e' `l^l "I J ~ ~ ~ -I O S'D~ 49095 Your f1 402394 PAR1}{ Jeiferaon Sav. xavisad 10/9/68 ~ L 1 ~G cB I ~ I GVes~ ~9f/~. /~/a c e 1717Z oIZ' Ilf . ,O Q / !SV / a~myra / or,C ~v6~'ris.on Scale i•_W' om~ TLie cerllflce thnt thn xbme le o bue mtl currce< plnt of rnrveY ~'*ulc LY ~~~e Ihle I'th 11•~Y ot QrtOJei, 1i6ep oiinsmeo~~vuo.orixuw~Lot 12, PALFIYM PAt1Y SUd'JN7SIOf1, County oL Jetfercon, State of Colorado, and tFs! 1Le loe¢Ilon a Jlmannione ol np 4ullulng ImNOeamenM. e, cuq ol tlpLta.oba'ny ln evidence or kno~rn to mo, unU mefOwM1 !tlrCOhq Lb0 premleee nra vecnm(cly aM1Own. 21iia yl¢t mlmlo Im Imn purtwaea nnU xhouW nat be ueW fOr con.lrvetl oq~e~ ooN Im"evemmex. /~O, pt~~s<<•Sp~, ~,p Wm. IL ISOmmin ,h Asvociates, inc. S f a~ Cancu ing 13r / Fr~g' cc ' I ~jl , City of Wheat Ridge Res. Add Structure PERMIT - 060417 PER1+1IT;N06 060417 ISSUED: 05/26/2006 JO$ADDRESS: 7105 29TH PL EXPIRES: 07/30/2007 DSSGR3PTIpN: 22'X 30' DETACHED GARAGE . CONTACTS . pydNER..'..303/433-1681 R & K HOFMEISTER OWNSR 303/521-5071 . t r PARfL"EIa:~ INE'O * * . ZONfi COIIS: UA USE: UA SUBDIVISIbN: UA BLOCK/LOT#: 0/ ~~y ESTIMATED PROJECT VALUATION: 5,000.00 FEES gxtenct Slcpired Permi 6xt6nd. fficpired Per 2 72.35 permit Fee 144.70 Plan ktev'iew Fee . 94.06 8`3~ Totai Valuation .00 ps-r' Uae 'S'a7c'~ . 90.00 r a 'T'OTAIi ■ ~ C ( nsion granted from 5/30/07 work to be doneuntil inspectiona on previous work have been ibiect to field inspection I kSTeby ceztify that the eetback dietancee propoeed by this permit application are accurate, and do not violate applicable brdinebcee,rulee or regulationaof theCity of t4neat Aidge or covenante, easemente or reatrictione oY record; that all npayusemept ehown, and allegations made are accurate; that Z have read and a9ree to abide by all conditrone printed on thie appllceLi n t~L aJ eume full reaponaibility for compliance with the YEaeat Rid9e Huildin9 Code (I.e.C) and all other aooliCap~t 9~~rdinances, for work under this permit. Plane subject to field inapection. Sign W Ci contxactor/owner date 1. Thie pmmit was iseued in accordance with the provieione eet forth in your application and ie aubject to the lawe of the ~ 6Cate 4L Colorado.and.to the Zoning RegulatSOne and euilding Codee of wheat Ridge, Colorado or any other applicable os8iaawee of the City. 2.Th18.pe1^mit shall expire 180 daye from the iseue date. Requeets for an exteneion must be received prior to expiration . dat8. An exteneion may 6e granted at the diecretion of the Building Official. 3. If-titii9.'.permit expirea, a new permit may be acquired for a fee of one-half the amount normally required, provided no , cha5iges..have been or will be made in the original plane and epecificatione and any auepeneion or abandonment has noC ..2zceeddA one (1) year. If changee have been or if euepension or abandonment exceeds one (1) year, full Eeea shall 6t pai,¢for a new permit. 4. No voYk'of any mamer shall be done that will change the natural flow of water caueing a drainage problem. 5. ~CbntTactor shall notify the Huildin9 Inepector twenty-four (24) houre in advance for all inepectione and shall receive vzitteri.approval on inepection card before proceedin9 with eucceeaive phaees of the Job. fi. The.J'ssuance of a pexmit or the approval of drawinge and epecifications shall not be conetrued to be a permit for, nor aa.approval of, any violation of the provieions of Che building codee or any other ordinance, law, rule or ze9ula[ion. All~plan review ie e t to field inspectione. Slgnatute:of Chief fic date IN&'P$CTZON R84II8S7 LINBs (303) -5933 BUILDING OFFICE: (303)235-2855 RSQU'£STS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. s_... _ AOL Read 1~1~101 Reply Reply All Fonvard Unsend I Action Delete Permit Extension for Permit 60417 Hello Kristy, Page 1 of 1 Atld to: Blog, To Do, C I need to extend my permit again. No work was complete during the winter months and I have been extensively traveling with my job. The structure has been constructed, roofed, and gutters installed. Garage doors will be in week and I have begun preparing for stucco application, so we're real close. I dropped by today and Chris, I believe, informed me of another fee to pay which will not be an issue. I'll come back in to pay the fee and hopefully be granted the extension. Thanks, Robin Hofineister AOL now offers free email to everyone. Find out more about whaPs free from AOL at AOL,com. DQ9 ssu-caA- A)~ v01 ~n ~ - LAA `lwk Cr~ ~Asp c" v3t epe S a-✓wj ~j o J,6~S ~ http://webmail.aol.com/27618/aol/en-us/Mail/DisplayMessage.aspx 6/20/2007 (taE vu~ ~ L n }o oA~s~+~ a~ D. 4~~ - _ _ v,rp~' Iv ~ ` ~r -,r 3~D E~~~ ~ ~ d. _ _ ~ 5~,,~h _ 7,/05 M/ 2~ ~~g~~5 owk(¢F e~.~: r" ~9 - t~a~6a~ ~~sra~l _ _ _ _ ~,a ~ ~~y~ ~`4'y ~ N e , . I ^I ~pR~l~ ~ \ ~ ~ I - - ~ 1 o ~ 7ros w z9 a y~P~ Kur / U - sow: _s {~oFME~S~r~. oP~~~ ~~oat~ F- ! `?•ft ILIA.,. !I l,l ~*1 ~l I r s.i I _ lk a S'i{; 1! I ' I` ` , -a rf•A.. e U abl, tl .,a , j ~Jz'1 Y' ! q .F xt. lF~E`~',Lci t rpNi':~'• ' ' 1fi I11 i'?7~I I f°'7!, l q ~~1C_)'t`F. " C f i~i`.4. t , l i J-1 A yy p F;,i al AQQ y9 7r [~J_MAIN 9 AI. 3. rklr Yy iii;. \ w. r<-, e-la ~J ! ~_G ''d Ak r. L ' h S I[ D NAp A )~t X ~ P 4 n pS(,;. i ,A pF f,' f _ ~P A AID ~F f.i}N'?_ i 3 w i- w 1 ~ ~ naE R1, ~ re 1!A 0 ) 4A L b W"5 Nl;"W_~ sS~I r N" ~~lr v { NF)" r I: ,i L u hJY kli~ ~tl {Fe;~+~ 2t'a! - , AS{i it . 1 F, 1t w i r - u 1c~II1 iP`~ Ci';D NF t Jl C 14 t.Uf()'a+~[ 1 l f .PI ' i p(* OF l F t I' YPII~_1 ~(51.~ IIVZ.~ .,w' e*?+:4 I~„ +P iI1l C HCF` y~ ` 'rY ~M1I . 14 'if ~l III ~.iP.F 1 I :I U.. .~14" 0.. 1.. } ME H R T SIP I I l AN V 41' L it V r I ( o I C ~bAl f "Um IIiS . ) IA kAi h .r` ~l " ,E{FL Ut r M~N1M~l~< PEW r 14~i, t, ,I C c I 4r Jli ,f ~N~I . , NLI:f P ?THL!dI SE. mW__ m I'(pF.' A Ai_L V10P rRAM, iNF, SHAt! Nrlr~M (I TH"" NA t iNk [)EE.IvN 3E'EI:[I 1',,~ I`.!IW C1k_ WCIuI.J N' lC _ lltN , ~P ~i rD~l : d n1 i . , ~A l~,S . . , U - AS i ; r I l~ I z 'Nk . ~ f 10 I~ u u! i " Y , AL L R t _ uR S1, r C 5 1 'il~ .,,'.t. f.UNLIr..(0 1W HAVE • C illiNll ! l T I , I1F , Jf L ANA; HEK i)H " C`.CilU SUE i" ; E E3A, ~kL C311 ~tPIIR rIA PAR'rMFN,` RUN lJF.li,NV-' ~JTH 'H ASIUI~' i5N 1!~A 04 RU!RfNr SUIT, ARE WIN I ~JI1~ " AIi 41 1) F C d C r I iAiNINh `,1 TdF.AC f l1'rN~Ad ILlN1 E OF AN;1 OR jU (i dE ,C~t t C:~ AND ~it1`. C N07 ..t ( i BY A 1I~ T R IIt 'RI. tJy~TURAl f~:/!!~~ 117H7 r i F F - IVERIFIED, r + p pn I 6 E;k'r~~C !Jr I IzL,` ,1 1 ( IN ~ ~ ElF;S~>♦ N 1 v ~(IIl., iINI?'. ilfN~, ~1rr.~E~l1,A~ L0-_IfR~ RCt;Tt~f{A Z 5! i~ FOR 00 > F1C R LP NCEi 4• Nl7$CI~ N I CT 14 f UNIIIA I ~E l ~~,a X I~Ik ~A~ d )f11 i AC ~t1(f ! M- 1~riV5fIE GjJ„"' f r ?FL 1t ILI] AL AI 11 1 M1EN I tW`; t IN 'TRU"'TURAt. rPWd NC` IIAEC A~vGNI 1II"' D_C. I ;~w !':'~3EATION li. r;RCENHOUSE ~EFNJIOUSE FRAME n`A~ I r~ XIS' LAR T,0 F"EMAIN 1/2' Ac T IPr'RFi ~71J FE-1 CE FR-' E1 Rn, NW REQ'B Aief A 01 WN I A~-T E - A l { "FI UUtdE ? . #5 T ,s,If lE_ l L7 * . GR,,)tJNU C 0 N I I ._0 z - ~I !.U! CRC T GRADE BEAD r° 'jo1Cl I?; l 4N! A `X v"hs',A T ATH (!?UUJ[ N41;''! i;'.1N!J II ! I 9 xti' ';~m1 FS ° J ; 0 ~ 6 F ON $ 1 "se° 0 `ZQ \ 0 F C0 ` mnm, LXJ ' C> Imo; 3 W I W s DRAWNG - I a (~z A\T1►,~~b! 1 h s 1"-- 41 5/8' ,,-2" 41' REMOVE PORTION OF EXISTIW-s OVERNANGs AS REQUIRED 19'-5 5/8" 2 BAY5 0 41" 1'-10' FRONT ELEVATION 1/4"= 1 "_0n /E~ TING STRUCTURE UJINDOW , 7 41" I" ROOKS T FAN - EXISTING SLAB - TO RAMAM - CiREONI•IOUSE ENCLOSURE MULLION SPACING: REMOVE PORTION OF STOOP EXISTING SLAB AS REQUIRED 1" 41-5/8" 2' 41" 41' 4 BEAM i± 1X4 ALUM . ~N N ~ {i ~ 14LX`I~ki►9 OFJM PIE01'!~~ Ox - 240 0 i J I q a: A" n_ !y6 A Fow F- . W D A2 ow a EXISTING SLAB - TO REMAIN tt V N SEE STRUCTURAL. - DRALWWs fS-U FOR FOLNDATION e SLAB DETAILS P V-31/4't CROSS SECTION / 1/4"_ _O," A - - REMOVE EXISTING PATIO COVER 41" 41" in W N U co z U O L,J a ag to x 0 LJ o~i U N E- W I ' a: n W 4 M t\ PROJ No: vs5o5os Date: 5/23/95 DR: RR CH: DRAWING No. A-1 OF 2 NQ,1et COOKWWRW"U APOOR MNlflIL1M"MMt0"SAWO W"?i" MWM TO NIT V"VAON OR 0100ft 1/4' TEMPERED GLASS RUSSER SEAL GLAZNG BAR ,2-1 3/6' X 4' EXP. BOLTS ow Ojc. U Q NEW ccNr.. FOUNDATION 4 Q a n, Q 1 2 - Q 11- S19. CAP FLASWING - CARRY UNDER SWNGLES (MN. 89 ~n0 with aview 114' TEMPERED GLASS H -073 073DWG2 RUBBER UMATW SI SEAL STRIP i~ RUIMER GLAZING - N BLOCKS J ~I x~$ / AliACHM- UN y 3/8' X 3' LAG ON LiCM ba BOLTS • 8' O.C. dig WO NEW FRAMING W $ FRQMNG L 2X IBLOCKMG s 2.3/8'X4'LAG =e BOLTS 0 Ib' O,G. U4' TEMPERED GLASS _4 (NEW) 2X6 SEE DEL 12_, W 0 U 00 z ~0 GENERAL NOTE5 N = 0 N 1. Design, fabrication and construction of all structural elements to oubject to F, W the provisions of the Uniform Building Code, 1991 edition. = W O 2. Live loads used In design - sea structural notes. F- a oW 3. GLAZING FRAMES M n 3 A. All components and glass are supplied by ROOMS WITH A VIEW and certified to most the following requirements: 1991 USG 3403 fully tempered glass 1991 USG chapter 28 alum. components are 6063 T6 N-16 kof. Table 28-d, F,S.= 1.65. IOJ No: V950508 08: 5/23/95 RR CW: DRAWING No. A-2 OF 2