HomeMy WebLinkAbout7250 W 31st PlaceCity of Wheat Ridge
Residential Roofing PERMIT - 201704511
PERMIT NO: 201704511 ISSUED: 07/20/2017
JOB ADDRESS: 7250 W 31st PL EXPIRES: 07/20/2018
JOB DESCRIPTION: Residential Re -roof to install GAF Timberline ArmorShield II asphalt
shingles with 25 sq.
*** CONTACTS ***
OWNER (970)988-1473 JENSSEN CLAY
SUB (303)295-2220 Tomas Wofram 110052 Core Contractors, Inc.
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,500.00
FEES
Total Valuation 0.00
Use Tax 157.50
Permit Fee 172.60
** TOTAL ** 330.10
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are
required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and
water shield is required. Eave and rake metal is required. A ladder extending 3 feet above
the roof eave and secured in place is required to be provided for all roof inspections.
Roof ventilation is required to comply with applicable codes and/or manufacturer
installation instructions, whichever is more stringent. In order to pass a final inspection
of elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer technical representative stating that "the application of the roof at (project
address) has been applied in accordance with the installation instruction for (roof
material brand name) roof covering" is required to be on site at the time of final
inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
PERMIT NO:
JOB ADDRESS:
JOB DESCRIPTION:
City of Wheat Ridge
Residential Roofing PERMIT - 201704511
201704511 ISSUED: 07/20/2017
7250 W 31st PL EXPIRES: 07/20/2018
Residential Re—roof to install GAF Timberline ArmorShield II asphalt
shingles with 25 sq.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and maybe subject to a fee equal to one-half of the originalpermitfee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspectio Services Division in accordance with established policy of all required
inspections and shall not proceed or conceaumwk wi cut itten approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting o . not onstrue be a permit for, or an approval of, an violation of any provision of any
appli�,." code cyr�lly�or a egulation of this jurisdiction. Approval of work is subject to field inspection.
V/7
Signature of Chief Building Cwt, <al Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dan Schultz
I
From: no-reply@ci.wheatridge.co.us
Sent: Wednesday, July 12, 2017 12:27 PM
To: Permits CommDev
Subject: Online Form Submittal: Residential Roofing Permit Application
Categories: Danny
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
7250 West 31st Place
Clay Jessen
970-988-1473
Field not completed.
Do you have a signed
Yes
contract to reroof this
property?
25
It will need to be
provided at the time of
/
No
permit pick-up.
CONTRACTOR INFORMATION
Contractor Name
Core Contractors
Contractor's License
110052
Number (for the City of
25
Wheat Ridge)
Contractor Phone
303-295-2220
Number
house predominate pitch is 4/12 using GAF Timberline
Contractor Email Address
docs@coredoes.com
Retype Contractor Email
docs@coredoes.com
Address
DESCRIPTION OF WORK
Are you re -decking the No V
roof?
Description of Roofing GAF Timberline ArmorShield II
Material
Select Type of Material: Asphalt
If "Other" is selected
Field not completed.
above, describe here:
How many squares of the
25
material selected above?
Does any portion of the
/
No
property include a flat
roof?
If yes, how many squares
Field not completed.
on the flat roof?
TOTAL SQUARES of all
25
roofing material for this
project
Provide additional detail
house predominate pitch is 4/12 using GAF Timberline
here on the description of
2
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract
value or cost of ALL
materials and labor)
500.00
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant Karen Tobin
Email not displaying correctly? View it inyour browser.
3
11
CONTRACTORS
ROOFING SYSTEMS
Property Owner
Agreement
"Doing it right matters"
Effective Date
Clay Jessen 06/24/2017
Property Address
7250 W 31 st PI
City/State
Zip
4501 Logan St,
Denver, CO 80216
303.997.1559
Wheat Ridge, CO 80033
Primary Phone number Secondary Phone Number
9709881473
Email Address
clay.jessen@gmail.com
Terms:
By signing this agreement, the property owner authorizes CORE Contractors, Inc. ("CORE") to perform the work and supply the materials as
agreed upon by the property owner's insurance carrier. The homeowner agrees to use CORE exclusively, and authorizes CORE to obtain labor
and materials in accordance with the scope agreed to by the insurance company and the specifications set out in this agreement to accomplish the
replacement or repairs. The initial proposed scope of services is attached to this agreement. This agreement does not obligate the homeowner or
CORE in any way, tmless the damage is approved by homeowner's insurance carrier.
Roofing Scope:
The roofing system replacement includes all shingles,
underlayment, valley linings, and miscellaneous flashing,
per local applicable municipal code. This also includes full
clean-up of the property and a 5 year Roof Workmanship
Additional Rooting Scope Notes
Warranty (on full roof replacement only). A one year
workmanship warranty is included on all non -roof work-
performed
orkperformed by CORE.
Due to the nature of repairs related to insurance claims, this contract includes an estimated repair price of the roof system.
12500
Because the final scope has not been agreed upon with the insurer, this repair price may change. The amount of this
contract is for 100% of the replacement cost approved by the insurance company for the work to be completed by CORE.
Reaching agreement on the full scope of repairs involves considerable time on CORE's part and we will not proceed with
that phase unless you agree to allow us to do the work once the scope is agreed upon. By signing this contract, you
authorize CORE to reach an agreement on the scope of repairs on your behalf. CORE agrees to bid the work using the
primary insurance industry pricing database (Xactimate) based on the scope of work agreed upon with your insurer. You,
the homeowner, recognize CORE Contractors, Inc. as a general contractor and as such shall be entitled to overhead and
profit, at customary insurance industry rates (20% on Xactimate line items). Any substantial additions or deductions to
the scope of work will be handled on the Customer Verification Form. The property owner, you, must agree that, once a
scope of work and project cost is agreed between CORE and the insurance carrier, they are responsible to pay ONLY the
deductible amount per their replacement cost insurance policy. Any further changes, in addition to the insurance work,
POWERED BY C,i C8f1VdS�1, Cf= 1 i
must be requested in writing, by the property owner.
If, you, the property owner, plan to use the proceeds of a property and casualty insurance policy issued pursuant to Part 1
of Article 4 of Title 10, C.R.S. to pay for rooting work, pursuant to Section 6-22-105, C.R.S., THE ROOFING
CONTRACTOR CANNOT PAY, WAIVE, REBATE, OR PROMISE TO PAY, WAIVE, OR REBATE ALL OR PART
OF ANY INSURANCE DEDUCTIBLE APPLICABLE TO THE INSURANCE CLAIM FOR PAYMENT FOR
ROOFING WORK ON THE COVERED RESIDENTIAL PROPERTY.
PAYMENTS ARE TO BE MADE: HALF (OR FIRST INSURANCE CHECK RECEIVED — ACV CHECK) UPON
DELIVERY OF ROOFING MATERIALS, AND FINAL BALANCE UPON COMPLETION OF WORK. THE WORK
IS TO BE COMPLETED WITHIN APPROXIMATELY 90 DAYS OF EXECUTED CUSTOMER VERIFICATION
FORM. CORE SHALL HOLD IN TRUST ANY PAYMENT FROM THE PROPERTY OWNER UNTIL THE
ROOFING CONTRACTOR HAS DELIVERED ROOFING MATERIALS AT THE RESIDENTIAL PROPERTY SITE
OR HAS PERFORMED A MAJORITY OF THE ROOFING WORK ON THE RESIDENTIAL PROPERTY.
All estimates or contract amounts include a 3.5% discount for cash or check transactions.
Property Owner's Initials
Right to Cancel
You, the homeowner, have the right to rescind this agreement and obtain a frill refund of any deposit within 72 hours
after entering the agreement. If you plan to use the proceeds of a property and casualty insurance policy to pay for the
roofing work, you may rescind this contract within 72 hours after you receive written notice from the insurer that your
claim has been denied in whole or in part.
Property Owner
Clay Jessen
Property Owner Signature
Dale
06/24/2017
Insurance Company
State Farm
nwEacD BV canvas
i CITY OF WHEAT RIDGE
9r(303)
Building Inspection Division
_:�(303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: A)
Job Address: r'? U 0
Permit Number:
❑ No one available for inspection: Time /() /e,• AtPM
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
�\
Date: `" Inspector:'
DO NOT REMOVE THIS NOTICE
0
v
m
~
y
a
~ CD
0
O y ~
y
~ ~
~ a
o CD
~ o
0
o ~
N ~
y C
W Q
~
7
3 m
~
~
N
A
~
~
m
O
W
N
W
a
in
m
w
w
❑
Z
0
0
~
m
m
N
w
Q
fD
O
~
fn
7:3
~
0
~
~
~
m
~D
~
~
~
C-
0
a
a
a
a
I
(D
N
N
A
3 D
Z O
C 3
3a ~1
~ (D
Z
CO)
M
m
n
~
Z
Z
O
~
n
m
1(41
~
♦
w
Nwan
. 1
O
-n
m
en
~w~o m
V >
d ~
x
: ► ~ !City of V'Vheat Ridge
Residential Roofing PERMIT - 080672
PERMIT NO: ~ 080672 ~ . ISSUED: 06/18/~2008
JOB~ADDRESS.: 7250W 31ST;PL ~ . ~ EXPIRES: ~12/15/2008 ~
DESCRIPTION: Reroof T/O!replace w/ Elk 30yr24.5 eq
~ • s t CONTACTS x * . . . . . . . . . . . ~ .
owner 303J~526-8797~ ~ Helen and Don Basao
gc~ 303/425~-7531 John Borfitz 01-9983 J& K Roofing Inc.~
PARCEL ~INPtr
ZONE CODE:. UA . ~USE: UA.
SUBDSVISION: ~~.0584 ~ BLOCK/LOT#: .0/
FEE SUP4'QARY .~ESTIMATED~PROJECT VALUATiON:~ 5,267~:50
~FEES
Permit e'e ~ . : . . . 162.90
Total ~luatxon~. .00 .
Use ~Tax 94.82 ~ ~ . ~ .
TOTAL .x~~. ~ . ~ . ~ . 857.72 . . . . .
Conditionsf ,
6 nai2 installation 6 mid-roof inspection required.
I heroby Cert`fy ttraG tt}e eetback distancee propoeed by thispermit application are accurate, and do not violate appliCable
ordinance¢~ rJles or tegulatiorie of the City of Wheat Ridge or covenante, easemenee oz restrictions of record; Chat allmeaeuremente~ hown, and alleg ions made are accurate; that Y have read and a9ree to a6ide by all conditioneprinted on.this
applicat and tilat Ieu Fullreeponaibility for <pmp~ancewithfhe Wheat Ridge BuiPfling Code (I.H.C) and all oCrier
a db1E Wheat $jd4 ncee,Eor mOrk under thSe et t. _~lans~6ubje~t to field ine ection:
SSg ure oP.aontraccox/r er L/ .
1. Ths ermit wae ieaued inaccoidancewiththe provieione eet forth in your application and ie..eubjec[ to the lawe ofChe
State of CoIOradoandtothe Zoriing Regulationeand HuilQing Codee of Wheat aidge, Colorado or any othei applicable'..
ordinances of the City. ' z. Thle permtt ehal3expice 180 daya from the ieeue date. Requeata for an extenaion muat be receSved pxior to.expiration
date. An extaneion may be granted at the diacretion of the Huilding Official. . .
3. If thaepermlt enpiree, a new permit maybe aequired for a.fee ofone-half the amountnormallyreguared,psovided nochan9ee have been or will bemade in Che.original plane and epecificatione and any auapeneionbr abandonmenE Aaa not
.
. exceeded one (1) yeai. i€changee have beea.o;,iP suspension or abandonment exceedsone-(1) year• full'r,tSeee eUall
be paidfor a newpermit. - a, No work of. any me[mer ahall be-done that will change the na[ural £low of water causing a dzainage problem. .
5. Contractor`ahall.notiEy the'SUildingInspeetoz twenty-EOUr (24) houza in advance for all inapectione and shall receive
written dpproval on inspection card before proceog}" with eucceeaive phaeee of the job. .
6. The Saeuance of a permit or theapproval of dra a[E,Q,' pecificatione ahall not be construed to be a pemiit for, noz .
a[~ appzoval ot, any-violatio~Q of the provisions tilding codee -orany other ordanance, law, rule or reguiatnon.Al1 plan revyew Sa.gyb~t~flUd inepectione
~
Signature ofChief HuUellnZpit
f~
Lcial ~ . date
5:.~(303)234-5933 BUILDING OFFICE:~(30~3)235-2.Bb5
iY 3PM ANY BUSINESS DAY FOR~INSPECTION THE FOLLOWING BUSINESS DRY~. ~
K~a<
oe`""EqT,~ . City of Wheat Ridge Building Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-235-2857
" Inspection Line: 303-234-5933 "
Building Permit Application
OWW"'Ito Sil:
Property Owner (please print): "SA v\, ' "c v~-
Mailing Address: (if different than property address)
Address:
City, State,
~~,VN
Contractor License
Date: pU -
Plan
Pormit #:w(pj)-
Phone: 3 C-3 " 5
Phone:
go , m Electrical City License Plumbing City License Mechanical City License
Company: Company Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: Approval: Approval:
Use of s ace description): Construction Value: 3 S-a(~D -SC~
(as calculafed Uer the Building Valuatlon Data sheeU
Plan Review (due at time of submrttal): $
s-isA,,v~c
36 ~D
Sq. Ft./L.Ft added: Squares 34 -S BTU's Gallons Amps
OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulavons of the City of Wheat Ridge or covenants, easements or restrictions of record; lhat all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1•assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under Ihis pertnit. Plans subject to field inspectlon.
CIRLCE ONE::
PRINT NAME:
PERSONAI
Paesnauem
HIGH DEFINITIONm
Prestique Pius High Definition
Pmductsixe ..._...13%k399'
Expasure 53f
PieceNBundl¢ 18
BunGles/$puere . 1198.5sq.fl.
Squares/Peliet . ._11
T'resticyue I High DefiniHan
SPyeu fmitetl wemnry period
S)"Ners mnprareOVE cwerepe tor
shinples and ep0lin6on lebarwith
prorNeE covemge for mmainder of
limi[ad wemmy pedoq plus en
opGOn for tnnslembiliM. '+-Vear
IimitrE vnM wernmy'. Wind
Cawnpe: rtenderd BO mph, exlended
IIOmph"'.
ltaised C'rofile
Protluctsixe 131ik38X'
Esposure . 5%'
PieceS/BUnEIe 21
Bundles/Square _._31100sq.R
Squares/Paliet ifi
RAISED PROFILE°
36roer inima xenenN Pniod
S'/"yaen nmDraeleE wrerpe for
Ninples end applicsNOn Iahor with
pmmeE tommpe far remain0er oi
IimibE wermrty panod, plus an
opnan tor vanshn biYly'. 5-yeu
timidd winG wernmy'. WmE
Cwerape: shMard ID mph.
Pmductsi[a _-._.._i3;rx 39%'
Expwum _..5JC
PieceyBuMle _..Jfi
Buntlles/Squem .4198.5sq.R
Spuarea/Pallet . 14
1'resiique High De~'inition
"mr rmmew.rremwriand:
St"yeemnortprare[ed cwanAe br
shinples end applieelian Nbor xtltli
pmrHad covanqe br rameinEer af
limitetl wmeerty period. Wus en
optian br imeuPoObilily'. SWar
I rmBee wina w.moty'. Woa
Cowmpe: stenEerE AO mph, eztenEaE
< Nmphw'
PmEUCbke 13;tk38%'
Ewo:ure ._5%'
ViacayBwdle ....__.72
Bundies/Squere _ 31I00 sq.ft
Sauami/Pallat _IB
30,Yau Filed werremY Penod:
S]"p~nroirprqemtl cwxepe far
Wn8las enE eppYCHian lebar with
Monhd cwenpe br nmtlnErt ai
limimd wemmy perlotl, qus m opum
for tnnAereEility`. &ywr limrced
vnnd wernnty. Wind Cavenpe:
rtenderd BO mph.
ACCESSORIES
T.' Ridge
Si:e: 131tk 9%'
Espoaure: 5%'
Pieces/Bundle: 72
Coveraqa; 36undlss=
imrnaar tans
Elk Starter Strip
19 Piece4BUndle
i Bundle • 110 Oiwar teet
Vented RidgeCresY"
Sixe: 17x13%'
Exposure: 9'/:
PiecedBOx 28 -
Coverepe: 5 boxee • 70U linaarfeet
'V'on-Vented RidgcCres["
Size: 9fPx133C
Exposum: 91:
Piecac/BaF 32
Coverepe: 4bmes=t001iixarfeat
Available Colors ICheck Availabil"MY. AnGque Slete. Aspen Whrte, Barkwootl. Forert Green, Xickory, Sablewood, Shakaxrootl, Weetheradxrood.
GaileryCollection: Balaem kmsP,Sienna Sunae[', WeaMered Sape :
All Prea[ipue anJ Palsed Profile mofinq producu canuin ElX WinGGuard'seelant WintlGuerd acrivates wHh tAe sunb heat, banGin9 Mi"iw iMO e wind end
weaMer-re¢iabn[ cover Mat nsuts Glow-oHs anE leelw.
NI hm19w M PYwd hNPo Mliqlo, nwt UL•MIInE ileiwnlM g1/ASTM U 1f61 dm'PG ULUMM RwWrn Ia moo/esirM 0 L'fl cMr "X'1 aM Clw'a' M IhtlN M
]lWASfM El W. All Pmtlpw mtl MbN heBN sYlylse cowPh~ the "i~m N ~ 0]IBi s wYl a W MLCOwIm VYlaw OwNI1M Cauds. le ICC royoWoRMnv. YI
YmYqw ned PiW PMIe WrylwwMq. ue4wa eMW 0 11C tD.IY ICC [wluWx2rvla ytnN rWrbrMl hWVwwtl IYYtl PMN ~ieGim4LLw~rb ICF
Et 60.IOiYl Moapont xM Nixtl PMI. WplsmMrio pWYn iYWr4 NwGniw (CW COUEAIllS ud YnM Mylmenl MtlM Tuu MpaMontA Ymvro.
SPECIF'tChT10M15
Scops: Work includes furnishing sll la6or,
materiels and equipment necessary m complete
instella6on of the ahinglas specifed harein. Hip
and ridpe'rype W be Elk Z Ridpe. RidBeCres[
(vented w nonvenrted) anNor HighPoint ridge vents.
All eyrosad metel suAeces (nashing, venis, etc.)
m be painrted with me[ching Flk roof accessory peint
-Pnqntion of RoW DecC Rpot deck m be dry,
well-seesoned 1' x 6' (2+.4mm x 152.4mm) boerds;
exterior-grade plywood (exDOSUre. 1 rated
sheethinq) at least 3/8' (9.525mm) thick
coMorming to Me spBCifications uf Ne American
Plywootl Assoeiation; 7116' (11.074mm) orientee
s[rendboard; or chipboard. Mos[ fire retardent
plywood decks ere NOT apDrovad substrates for
Elk ahingles. Consult Elk Field Service for
eDPlicavon specifications over aNer decks and
other slopes.
Muwislc UMedeymem for sinnderd moF sbpes, 4'
per Poot U01.6/304.8mm1 or Braater. epply non-
perforoted No. 15 or 30 esphalasemreted telt
underlaymem for low sloDes per foot
(101.6/d04.8mm) W e minimum of 1' par.foot
(50.M.emm)1, use twa plies of undedeyment
ovarlapPed e minimum of 1Y. Fes[eners shell be of
sufificierrt IenpM antl hol0in0 D~r fDr securing
meterial as required by ihe epplicatian insVUClions
prin[ed an shingle wrapper.
Complete aDDlicatiw insvucuons are published hy
Elk and prifrted on Ne beck ot every shingle
bundle. All warrarroes ere contlnAeirt upon Me
correct ins[ellation as shown on Ne insVUCtions.
These instrucnons ere the minimum requiretl in
meet Elk applicanon requiremeMS. In same arees,
building codes mey require edditionel applkation
techniques or methods heyond our instructions In
Mesa ceses, the local code mus[ 6e followed.
Under no circumstances will Elk accept applicetion
requiremenu less ihen ihose conrteined on vs
applicationinstructions. , .
For spaci(cafions in CSI format call 800354.SPEC
(7732) or e-mail specinfoDalkcorD.cam.
MIDWESi OPFICE• WHST OPFICE CORPORATE HEAOQUApTE65
800.226.6111 800.791.8545 ' 600354752
SOUTHWEST OFFICE NOBiNmEST OFPICE PLANi LOCATION
888355.5882 877.840J635 800355.4966
Canfidence Builbia
www.clkcorp.com
>SO0l'I. i0j
k
d ~
W o :5 ~
~ y C N
0 > O ~
~ Q V N
C ~ M
Q 0 y ~
W p ~ +
~i y
LL S Lo ~
O 0)42
} C M N
H~1~
V'~ oN
m M, M
M
W
U
H
Z
Z
O
U
W
a
~
Z
a D
F E
O Z
M M
a £
d
c a
N
N
~
v`
a
a
a
0
ID
~
q
V~
~
~
~
H
0
N
a
~
c;
M
Q
~
O
'
C;
c
y
[
a)
m
£
H
`o
{
C
Q
o
U
~
n
n
o
-a
a
~
~
>
(0
N
6
N
C
O
~
=
C
O
Q
~
C
0
a)
p_
U
z°
~
=
t
a~
0
N
~
~
TAMKO' Elite Glass-Sear AR PRODUCT DATA
TBB6&+rAB IISPHAU! Sa1N66BS _
Manufactured in Frederick, MD
TAMKOO ELITE GIASS-SEALOAR self-sealing
3-tab shinglas are made with TAMKO fiberglass mat
coated on both sides with a thick layer of weathering-grade
asphalt and surfaced with ceramic granules.
For applicatlon to roof decks with inclines of not less than 2 inches per foot For slopes
between 2 inches and 4 inches per foot, refer to wrapper instructions.
ADYANTABES
• 25-year limited warranty, 3-year FULL 3TART, limited transferability, winds up to 60 MPH.
• Superior fire resistance compared to organic shingles.
• 10-year Algae-Relief (AR) limited warranty that provides for cleaning of discoloration
caused by certain algae growth that may occur in areas with high humidity.
C697IFICATIONS 9BP087'S
Listed by UL for: Tested in compliance wiih:
Class A Fire Rating UL 790/ASTM D 3018, Type I; ASTM E 108, Class A
Wind Resistance UL 9971ASTM D 3161, Type I, Class F(110 mph)
UL 2390/ASTM D 6381, Class H(150 mph)
ASTM D 3462 ASTM D 7158, Ciass H(150 mph)
Fed. spec.: exceeds ss-S-ooisaa, TAS 100-95 Wind and Wind Driven Rain
Class A, Type i
Miami Dade County Florida NOA 05-0371.03,
C0608S Expirafion Date 04111/2007
Colors:
• White • Weathered Wood • Rustic Cedar
• Grey Blend • Tweed 81end • Slatetone Grey
• Rustic Redwood • Pastel Green • Pastel Brown
• Pastel Red • Empire Green Blend • Tile Red Blend
PR0DUCT BATA* ' Antique Slate • Rustic Black •
Shingle size
Exposure
( Shingles per square
Bundles per square
'All values slated as nominai
12-1 /4" X 36"
5-1/8"
78
3
CAUTION: The National Institute for Occupational Safety and Health (NIOSH) has con-
cluded that fumes of heated asphalt are a potential occupational carcinogen.
Do not heat or burn this product.
8M6OING PRilnUCTS
TAMKO Lago, Rooler Lopo, Eltla Gless-SeeN
ene rAM1c0r are reglareretl o-atlemerks oi
TAMKO' flwfi`g Pratluct6. Inc.
FOr infOtmetlm regardng a mpy MTAMKO'S IlrttlteC wertan(y, mntect yow bt~al TAMKO repreaentatlve, vkM us oMine at
www.femko.wm, w cell us aI800d41d891.
082005
Central Distrid
220 West 4M St., Joplin, MO
64807
800-641d691
Northeast Distria
4500 7amko Dr., Frederick, MD
27701
800368-2055
SoNheast District
2300 35M St., Tuscaloosa, AL
35401
800-228-2656
Southwest Distriq
7910 S. Central Exp., Dallas, TX
75216
800-443-1834
Westam District
5300 East 43rd Ave., DenveG CO
80216
800-530-8868