Loading...
HomeMy WebLinkAbout11467 W I-70 Frontage Road NUSG Design Studio I UL U419 - Fire Resistant Assembly, Fire Rated Assembly, Fire Rat... Page 1 of 2 USG % DESIGN STUD10 I )) 4 � v -T—?O Frd.itceye— Zol6ol eb �7 Ilk 24 in 24 in [610 mm] [610 mm] UL U419 Interior Partitions -Steel Stud (Non -load-bearing) Fire Rating 2 hour System Thickness 4-1/8" Assembly Options Gypsum Board - Two layers of 1/2 in. or 5/8 in. thick gypsum board applied horizontally or vertically • USG Sheetrock@ Brand EcoSmart Panels Firecode@ X - 5/8" (UL Type ULIX� • USG Sheetrock@ Brand Firecode@ C Panels - 1/2" (UL Type Q • USG Sheetrock@ Brand EcoSmart Panels Mold Tough@ Firecode@ X - 5/8" (UL Type ULIX) • USG Sheetrock@ Brand Mold Tough@ Firecode@ C Panels - 1/2" (UL Type Q • USG Sheetrock@ Brand Gypsum Base Imperial@ Firecode@ C - 1/2" (UL Type IP -X2) • USG Sheetrock@ Brand Gypsum Panels AR Firecode@ X - 5/8" (UL Type AR) • USG Sheetrock@ Brand Mold Tough@ AR Firecode@ X Panels - 5/8" (UL Type AR) • USG Sheetrock@ Brand Glass -Mat Panels Mold Tough@ AR Firecode@ X - 5/8" (UL Type AR) • USG Sheetrock@ Brand Mold Tough@ VHI Firecode@ X Panels - 5/8" (UL Type AR) • USG Sheetrock@ Brand Glass -Mat Panels Mold Tough@ VHI Firecode@ X - 5/8"(UL Type AR) • USG Sheetrock@ Brand Firecode@ C Panels - 5/8" (UL Type C) • USG Sheetrock@ Brand Mold Touu h@ Firecode@ C Panels - 5/8" (UL Type Q • USG Fiberock@ Brand AR Interior Panels - 5/8" (UL Type FRX-G) • USG Fiberock@ Brand Agua-ToughTm AR Interior Panels - 5/8" (UL Type FRX-G) • USG Sheetrock@ Brand Gypsum Base Imperial@ Firecode@ X - 5/8" (UL Type IP-Xl) • USG Sheetrock@ Brand Gypsum Base Imperial@ Firecode@ C - 5/8" (UL Type IP -X2) • USG Sheetrock@ Brand Firecode@ X Panels - 5/8" (UL Type SCX) City ct • USG Sheetrock@ Brand Mold Tough@ Panels Firecode@ X - 5/8" (UL Type SCX) • USG Sheetrock@ Brand Glass -Mat Panels Mold Tough@ - 5/8" (UL Type SGX) wheat Ridge Building Divison. http://www. usgdesignstudio.com/assembly.asp?id=920617&assemblyCategory=921052 7/5/2018 SUBMITTAL SHEET USG SHEETROCKBRAND ECOSMART PANELS FIRECODE" X Highly sustainable and ultralightweight 5/81n. Type X wall and ceiling gypsum panels for Interior applications • Meet Architecture 2030 Challenge for Products — Up to 25% less global warming potential (GWP)' — Up to 25% less water used in the manufacturing process' — Up to 22% less weight reduces transportation fuel energy by up to 20%' • Living Building Challenge`" Compliant • Contains 100% USDA certified biobased content • Up to 94.6% recycled content (regionally available) • Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material (meets CA 01350) • USGBC" LEED° v4.0—may assist in achieving 1-1/2 additional credits (up to 10 total credits) • Underwriters Laboratories Inc. (UL) Classification as to fire resistance, surface -burning characteristics and noncombustibility • Comply with ASTM C1396 specification for 5/8 in. Type X gypsum wallboard • Offer comparable sound, strength, sag and impact resistance to standard 5/8 in. Type X • Listed by UL in the most widely specified wall, column, floor -ceiling and roof -ceiling assemblies (refer to specific UL designs for complete details) Note: 1. Compared to standard 5/8 in. Type X gypsum panels as presented in the Gypsum Association's 5/8 in. Type XEnvironmental Product Declaration (FPI/GA/01/2014) with fresh water usage updated to be in accordance with ISO 14046. DESCRIPTION USG Sheetrock` Brand EcoSmart Panels Firecode" X represent a revolution in wallboard manufacturing, significantly reducing the need for natural resources and impact on the environment. These 5/8 in. Type X lightweight gypsum panels have been formulated to achieve all of the strength and performance characteristics as standard 5/8 in. USG Sheetrock' Brand Firecode" X Panels at a significantly lower environmental impact and reduced weight. They feature an innovative noncombustible gypsum core encased in 100% recycled face and back papers that form a high strength -to -weight ratio composite design. The natural finish face paper is folded around the long edges to reinforce and protect the core, and the ends are cut square and even. The long edges of the panels are tapered, allowing joints to be reinforced and concealed with USG Sheetrock' Brand joint treatment systems. The panels are UL Classified for fire resistance and can be used in any UL design in which UltraLight Innovation Type X (ULIXTM) panels are listed. On the face along the long edge of each panel, the UL Type Designation is printed for easy identification after installation. INTENDED FOR Commercial or residential applications where 5/8 in. Type X panels are required • New or repair and remodel construction • Load-bearing and non -load-bearing wood- or steel -framed fire -rated walls • Wall, column, floor -ceiling and roof -ceiling assemblies (refer to specific UL designs for complete details) City C.j Wheat:;, tliG�NoIT'S YOUR WORLD. BUILD IT USG Design Studio I UL U419 - Fire Resistant Assembly, Fire Rated Assembly, Fire Rat... Page 2 of 2 • USG DurockTm Brand Glass -Mat Tile Backerboard - 5/8" (UL Type SGX) • USG Sheetrock@ Brand UltraLight Panels Firecode@ X - 5/8" (UL Type ULIX) • USG Sheetrock@ Brand UltraLight Panels Firecode@ X - 5/8" (UL Type ULX) Steel Studs - 2-1/2 in. deep, 25 ga. spaced max. 24 in. OC Gypsum Board - Two layers of 1/2 in. or 5/8 in. thick gypsum board applied horizontally or vertically • USG Sheetrock@ Brand EcoSmart Panels FirecodeS X - 5/8" (UL Type ULIX) • USG Sheetrock@ Brand Firecode@ C Panels - 1/2" (UL Type C) • USG Sheetrock@ Brand EcoSmart Panels Mold Tough@ Firecode@ X - 5/8" (UL Type ULIX) • USG SheetrockS Brand Mold Tough@ Firecode@ C Panels -1/2" (UL Type C) • USG SheetrockS Brand Gypsum Base Imperial@ Firecode@ C - 1/2" (UL Type IP -X2) • USG Sheetrock@ Brand Gypsum Panels AR FirecodeS X - 5/8" (UL TypeARS • USG SheetrockS Brand Mold Tough@ AR Firecode@ X Panels - 5/8" (UL Type AR) • USG SheetrockS Brand Glass -Mat Panels Mold Tough@ AR Firecode@ X - 5/8" (UL Type AR) • USG Sheetrock@ Brand Mold Tough@ VHI Firecode@ X Panels - 5/8" (UL Type AR) • USG SheetrockS Brand Glass -Mat Panels Mold Tough@ VHI Firecode@ X - 5/8" (UL Type AR) • USG Sheetrock@ Brand Firecode@ C Panels - 5/8" (UL Type C) • USG Sheetrock@ Brand Mold Tough@ Firecode@ C Panels - 5/8" (UL Type C) • USG Fiberock@ Brand AR Interior Panels - 5/8" (UL Type FRX-G) • USG Fiberock@ Brand Aqua-ToughTm AR Interior Panels - 5/8" (UL Type FRX-G) • USG Sheetrock@ Brand Gypsum Base Imperial@ Firecode@ X - 5/8" (UL Type IP -X1) • USG Sheetrock@ Brand Gypsum Base Imperial@ Firecode@ C - 5/8" (UL Type IP -X2) USG SheetrockS Brand Firecode@ X Panels - 5/8" (UL Type SCX) • USG Sheetrock@ Brand Mold Tough@ Panels Firecode@ X - 5/8" (UL Type SCX) USG SheetrockS Brand Glass -Mat Panels Mold Tough@ - 5/8" (UL Type SGX) • USG DurockTm Brand Glass -Mat Tile Backerboard - 5/8" (UL Type SGX) • USG SheetrockS Brand UltraLight Panels Firecode@ X - 5/8" (UL Type ULIX) USG Sheetrock@ Brand UltraLight Panels Firecode@ X - 5/8" (UL Type ULX) Remarks • Stud size is minimum unless otherwise stated in design. • For the most up-to-date information refer to the UL Fire resistance directory U419 2 • UL Type ULIXTm requires the use of insulation for single -layer, steel -framed UL fire - rated assemblies. http://www.usgdesignstudio.com/assembly.asp?id=920617&assemblyCategory=921052 7/5/2018 LIMITATIONS 1. Avoid exposure to sustained temperatures exceeding 125 *F (52 °C). 2. Avoid exposure to excessive, repetitive or continuous moisture before, during and after installation. Eliminate sources of moisture immediately. 3. Maximum frame spacing for walls is 24 in. OC. 4. UL Type ULIX'" requires the use of insulation for single -layer, steel -framed UL fire -rated assemblies. S. Must be stored off the ground and under cover in accordance with Gypsum Association's Handling and Storage of Gypsum Panel Products (GA -801). INTERIOR INSTALLATION, USG Sheetrock' Brand EcoSmart Panels Firecode" X install and finish just like standard 5/8 in. USG FINISHING AND DECORATING Sheetrock' Brand Firecode' X Panels. Fastener type and spacing requirements are the same as for INSTALLATION standard 5/8 in. Type X. FINISHING AND DECORATING For high-quality finishing results, USG recommends USG Sheetrock` Brand finishing products. Painting products and systems should be used that comply with recommendations and requirements in Appendices of ASTM C840. For priming and decorating with paint, texture or wall covering, follow manufacturer's directions for materials used. Gypsum Association's Recommended Specification for Levels of Gypsum Board Finish (GA -214) should be referred to in order to determine the level of finishing needed to ensure a surface properly prepared to accept the final decoration. All surfaces, including applied joint compound, must be thoroughly dry, dust -free and not glossy. Prime with USG Sheetrock* Brand First Coat'" Primer or with an undiluted, interior latex flat paint with high -solids content. Allow to dry before decorating. TEST DATA To improve fastener concealment where gypsum panel walls and ceilings will be subjected to critical artificial or natural lighting, or will be decorated with a gloss paint (eggshell, semigloss or gloss), the gypsum panel should be skim coated with joint compound. This equalizes suction and texture differences between the drywall face paper and the finished joint compound before painting. When a Level 5 finish is required, use USG Sheetrock' Brand Tuff -Hide'" Primer -Surfacer. See USG SheetrockeBrand Tuff-Hide'Primer-Surfacer Submittal Sheet (J1613) for limitations and application instructions. For more information, refer to USG literature Finishing & Decorating Gypsum Panels White Paper (J2010). Property ASTM Test Method ASTM C1396 Specification UL Type ULIx'" 5/8 In. Wallboard Noncombustibility E136 Pass Pass Surface -burning FlameSpread E84 Flame Spread Index, not 5 characteristics ................................. ..................................... greater than 25 ........................... ................... ...... I ......................... . Smoke Developed E84 Smoke Developed Index, 5 ..................................................................................................................................................... not greater than 450 Classification E84 Class A Core hardness (Ibf) Field ...................................................................................................................................................... C473 (B) Not less than 11 Meets or exceeds End ..................................................................................................................................................... C473 (B) Not less than 11 Meets or exceeds Edge C473 (B) Not less than 11 Meets or exceeds Flexural strength (Ibf) Parallel .................................................................................................................................................. C473 (B) Not less than 46 Meets or exceeds Perpendicular C473 (B) Not less than 147 Meets or exceeds Humidified deflection (in.) C473 Not greater than 5/8 in. Lessthan Nail pull resistance (Ibf) C473 (B) Not less than 87 Meets or exceeds Note: For more information on sound performance, see USG literature USG Sheetrock `Brand EcoSmart Panels Sound Performance Selector Guide (W82880). City, PRODUCT DATA Thickness Lengths Width' Weight', nominal Edges Packaging COMPLIANCE PRODUCT INFORMATION See usg.com for the most up-to-date product information. GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. For more information, visit ul.com/gg. CAUTION Dust may cause irritation to eyes, skin, nose, throat and upper respiratory tract. Cut and trim with a utility knife or hand saw to minimize dust levels. Power tools must be equipped with a dust collection system. Wear eye, skin and respiratory protection if necessary. If eye contact occurs, flush thoroughly with water for 15 minutes. If irritation persists, call a physician. Do not swallow. If swallowed, call a physician. For more information call Product Safety: 800 507-8899 or see the SDS at usg.com. KEEP OUT OF REACH OF CHILDREN TRADEMARKS The trademarks USG, FIRECODE, FIRST COAT, SHEETROCK, TUFF -HIDE, ULIx. IT'S YOUR WORLD. BUILD IT., the USG logo, the design elements and colors, and related marks are trademarks of USG Corporation or its affiliates. The trademarks IBC and INTERNATIONAL BUILDING CODE are trademarks of International Code Council, Inc. The trademarks LEED and USGBC are trademarks of U.S. Green Building Council. The trademark ARCHITECTURE 2030 is a trademark of Architecture 2030 Corporation. The trademarks DECLARE and LIVING BUILDING CHALLENGE are trademarks of INTERNATIONAL LIVING FUTURE INSTITUTE. USDA BIOPREFERRED is a trademark of United States Department of Agriculture. NOTE Products described here may not be available in all geographic markets. Consult your USG Company sales office or representative for information. The information in this document is subject to change without notice. USG Corporation assumes no responsibility for any errors that may inadvertently appear in this document. NOTICE We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered. SAFETY FIRSTI Follow good safety and industrial hygiene practices during handling and installation of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read Safety Data Sheets and related literature on products before specification and/ or installation. UL Type ULIX, 5/8 in. (15.9 mm) 8-16 ft. (2438-4877 mm) 4 ft. (1219 mm), 54 in. x 12 ft. (1372 mm x 3658 mm) 1.8lb./sq. ft. (8.8 kg/sq. m.) Tapered Two panels per bundle Notes: 2. Other sizes available by special order. Check with your local USG representative for availability. 3. Represents approximate weight for design and shipping purposes. For specific product weight in your area, contact your local USG representative or call the Customer Service Center at 800 950-3839. • Meet or exceed ASTM C1396 Section 5 for 5/8 in. gypsum wallboard, Type X • Classified as a Class A Interior Finish Material per Section 803.1 of the International Building Code' (IBC") • UL Classification as to fire resistance, surface -burning characteristics and core combustibility • Meet Architecture 2030 Challenge Criteria for Products • Living Building Challenge- Compliant • USDA Certified Biobased Product • Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material (meets CA 01350) SUBMITTAL APPROVALS Job Name Contractor Date 800 USG.4YOU 800 (874-4968) usg.com Manufactured by WB2859-USA-ENG/rev.5-18 United States Gypsum Company © 2018 USG Corporation and/or 550 West Adams Street its affiliates. All rights reserved. Chicago, IL 60661 Printed in U.S.A. City Wheat Ridge ITS YOUR WORLD. BUILD IT! i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE t \ �- • Inspection Type:_ Job Address: Permit Number: J ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: `!; r Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -7 o3 IE� FZ A I Job Address: / 7---76 l k�'� I v Permit Number: ❑ No one available for inspection: Tim - /PM Re -Inspection required: Yes �o When corrections have been made, ca(1.. re -inspection at 303-234-5933 Date ' "" t(D( lnspector. DO NOT REMO'f/E THIS NOTICE i CITY OF WHEAT RIDGE Buildingfinspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-89 Fax INSPECTION NOTI E Inspection Type: `T'p=a 'E`r -►=- /2�1 Job Address: 7 PermitNumber: ,moi 1 C 1 i if, Y( r-) C C i V� G G'r 1�- f F r 1 �1 r1a f ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes DO When corrections have been made, call for re -inspection at 303-234-5933 Date: % Inspector: --- DO NOT REMOVE THIS NOTICE 4, CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: E, A Job Address:;�' `fo-ALk1 tai Permit Number: Z + ❑ No one available for inspection: Ti M Re -Inspection required: Yes No When corrections have been made, Icaflor re -ins -ins at 303-~2334-5933 Date:"'- tnspec i CITY OF WHEAT RIDGE _:�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE j Inspection Type: 1 Uu r �' rrp e", ' Job Address: % i �-� w -J--- `70 f Permit Number:(>17 0 L�1 J ❑ No one available for inspection: Time ~' AM/PM Re -Inspection required: Yes f1-00 When corrections have been made, call for re -inspection at 303 -234 - Date: 2-`7 / Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE -1�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: ?C)'3 �0 Ft -61—^ Job Address: 1 I V 67 W ! --�O reENT Permit Number: 20 1 �130Zq q� ❑ No one available for inspection: Ti /PM Re -Inspection required: Yg� When corrections have been made, aU..for re-inspe�a# 33-234-5933 Date: s `` Inspector: f DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE - Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -3 b I- kc v 9 A ►' a m ('L? -1 Job Address: I) Ll & i VJ :7- -7D Permit Number: 'a o d R o c, L-1 Z-1 A ❑ No one available for inspection: Time 1 V = 39 AI'PM Re -Inspection required: es .No When corrections have been madel call for re -inspection at 303-234-5933 Date: 1 J -1D 1 Inspector: —T-6 DO NOT REMOVE THIS NOTICE �a i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 1-3 o u l ry l b n Job Address: (1 `J (o -7 W - 3-7o Permit Number: o 44 ROUQ/ 1T''IVh,,nn a,n ❑ No one available for inspection: Time - &/PM Re -Inspection required: No When corrections have been made, call for re -inspection at 303 -234 - Date: 1?111-5 / 9 Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Comm. Tenant Finish PERMIT - 201802944 PERMIT NO: 201802944 ISSUED: 11/29/2018 JOB ADDRESS: 11467 W I-70 Frontage Rd N EXPIRES: 11/29/2019 JOB DESCRIPTION: 1514 sq.ft., Tenant Rocky Mountain Barrel Co, existing tenant interior update. Non-structural improvements, electrical, and plumbing. *** CONTACTS *** OWNER SIX OAKS PARTNERSHIP GC (303)210-5991 Scott Falcone & Frank Walley 150181 SF Construction Inc SUB (720)601-6004 Andrew CoatarPeter 180111 Stellar Electrical Contractors SUB (321)624-0027 Richard E. Mecabe 160280 Mecabe Plumbing LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 420 / Storage Warehouse; 0 BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 33,093.00 FEES Total Valuation 0.00 Plan Review Fee 354.61 Use Tax 694.95 Permit Fee 545.55 ** TOTAL ** 1,595.11 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge Comm. Tenant Finish PERMIT - 201802944 PERMIT NO: 201802944 ISSUED: 11/29/2018 JOB ADDRESS: 11467 W I-70 Frontage Rd N EXPIRES: 11/29/2019 JOB DESCRIPTION: 1514 sq.ft., Tenant Rocky Mountain Barrel Co, existing tenant interior update. Non-structural improvements, electrical, and plumbing. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with thispermrt. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work tobeperrmeisdislsed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original ermrt fee. 3. if this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The pen -nit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuanc r granting ofermit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable od.0 or 4ny ordi ce or regulation of this jurisdiction. Approval of work is subiect to field insnection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY City Of W heat Ptjdgie comm UNiTy DEVELOPMENT Building & Inspection Services Division 7500 W. 2911' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cDci.wheatridge.co.us FOR OFFICE USE ONLY Date: V Plan/Permit #� p Plan Review Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Owner Property Owner Email Tenant (Commercial P Phone: '7 Z0-474 -6 (8S Property Owner Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Eng1neer E-mail: Phone: Contractor Name: City of Wheat Ridge License #: s n Phone: Z2 t 3 Contractor E-mail Address: ('3 Lf zLX cd C sm For Plan Review Questions & Comments (please print): CONTACT NAME (please print):("rN? �'_ Phone:_ 2-04:1 CONTACT EMAIL(p/ease print): f)W4CL OM t ✓1L CC -WL Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # ❑ COMMERCIAL ❑ RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. n` C6 o -n Q tlr1aV�4 v" ©oeote-v1t. ✓i `k K c c, -r tkf UYl J Sq. FULF l '5 ( Ll BTUs Gallons Amps Squares Commercial Projects Only: Occupancy Type: Construction Type: J j� Occupancy Load: j Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first andlastname): / c DATE: Printed Name: R! l�/l i yl—c DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: Reviewer: ls�u �� lob-Z9C�� BUILDING DEPARTMENT OMME TS: Reviewer: ttl►�L�� PUBLIC WORKS COMMENTS: Reviewer: Building Division Valuation: S City of W heat�idge COMMUNITY DEVELOPMENT SUB -CONTRACTOR AUTHORIZATION FORM *This application must be signed by each sub -contractor confirming the same.�� Project Address: i/g(&J LJ rev F=rmm &e cW tJ Permit General Contractor: S F +; o-vk Electrical Contractor - Wheat Ridge License # / ` 6J / II' i Company Name: State License # Signature of Authorized Agent Phone',,,f: 746, 60L(,;-0011 Master #: g M E C)&an Plumbing Contractor - Wheat Ridge License # ate Company Name: He(lt4ac P1CLM610,t_z Phone #: 3Z (-6Z_q -0OZ__V State License #: l�S(IS L( Master #: ()6 600 Signature of Authorized Agent Date Mechanical Contractor - Wheat Ridge License # Company Name: Signature of Authorized Agent Phone: Date *This application must be signed by each sub -contractor confirming the same. eN�s ZvlgpZ9M�i �V <NoReply@mobile-eyes.com> ' 1 , , Permit application accepted - Arvada Fire Protection District Nov 5, 2018 at 4.52:40 PM <blakeromineft mail. com> Your permit request for Rocky Mountain Barell at STE 11467,11457-11475 West Interstate 70 Frontage Road Wheat Ridge, CO 80033 has been accepted. Plans are reviewed in the order they are received. The approximate review turnaround time is 2 weeks, There are NO expedited reviews. The Job Number is: 181-10,50,02 Description: Removal and replacement of non structural walls Replace ceiling the Add cabinets New carpet and paint Randy Slusser From: blake romine <blakeromine@gmail.com> Sent: Thursday, November 15, 2018 11:49 AM To: Randy Slusser Subject: Re: Plan review for 11467 W-70 Frontage Road - 201802944 I dropped them off about a hr ago Sent from my iPhone On Nov 15, 2018, at 11:48 AM, Randy Slusser <rslusser@ci.wheatridge.co.us> wrote: When you drop off the plans, please let me know and we can modify the plan set here at the office. Randy Slusser, CBO Chief Building Official 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2803 www.ci.wheatridee.co.us <i mage001. j pg> CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. From: blake romine <blakeromine@gmail.com> Sent: Thursday, November 15, 2018 11:12 AM To: Randy Slusser <rslusser@ci.wheatridge.co.us> Subject: Re: Plan review for 11467 W-70 Frontage Road - 201802944 Hello, There is a small change in the stamped plans that the architect forgot to change. It shows 2 wall types. Our intention is to do all walls with wall type 1 "building standard interior tenant partition" And to do zero walls with wall type 2 "building standard acoustical tenant partition". The client was trying to cut some cost and redoing and re -stamping would take a week. Hoping that we don't have to have the architect redo plans for these small changes, as both types are shown. We really would appreciate your help in this matter. Thank you, Blake Romine SF construction Sent from my iPhone On Nov 15, 2018, at 10:18 AM, Randy Slusser <rslusser@ci.wheatridge. Co. us> wrote: Blake, Yes, that will be fine. Randy Slusser, CBO Chief Building Official 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2803 www.ci.wheatridge.co.us <image001.jpg> CONFIDENTIALITY NOTICE: This e-mail contains business -confidential information. It is intended only for the use of the individual or entity named above. If you are not the intended recipient, you are notified that any disclosure, copying, distribution, electronic storage or use of this communication is prohibited. If you received this communication in error, please notify us immediately by e-mail, attaching the original message, and delete the original message from your computer, and any network to which your computer is connected. Thank you. From: blake romine <blakeromine@gmail.com> Sent: Thursday, November 15, 2018 10:10 AM To: Randy Slusser <rslusser@ci.wheatridge.co.us> Subject: Re: Plan review for 11467 W-70 Frontage Road - 201802944 Hello randy, Will be dropping off stamped plans here within the hr. The asbestos report I will be receiving this afternoon. Would it be ok to email the asbestos report to you directly ? Thank you, Blake Romine SF construction Sent from my iPhone On Nov 13, 2018, at 8:32 AM, Randy Slusser <rslusser@ci.wheatridge.co.us> wrote: Good morning Blake, Please see attached document for comments from the Building Division on your project. Please contact me with any questions. Randy Slusser, CBO Chief Building Official Office Phone: 303-235-2803 <image001.jpg> Project Description Project Address: Permit App. Date: Applicant: Applicant email: Plan Checker: City 01 Y V he -at PLAN REVIEW COMMENTS Tenant Finish 11467 W 1-70 Frontage Rd 11/6/18 Blake Romine blakeromine@gmail.com Randy Slusser Plan Checker email: rslusser@ci.wheatridge.co.us Plan Check No.: 201802944 Phone: 206-422-8662 Phone: 303-235-2803 The project plans were reviewed for compliance with the following codes and standards: 2012 IBC, 2012 IRC, 2012 IMC, 2012 ECC, 2017 NEC, 2012 IPC, 2009 ANSI/ICC, City of Wheat Ridge Amendments • TO EXPEDITE PROJECT APPROVAL: Please provide a written response indicating how and where each comment was resolved on the plans. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • For clarification of any plan review comment, please call or email the plan checker listed above. r` tri° 0' �A/[d nl�mjmkfkjjl-y Dfvt vori kip Building Division Comments 11/13/18 1. The State of Colorado requires asbestos testing when certain thresholds of demolition are met. For Public and commercial buildings, the trigger levels are: 50 linear feet on pipes; 160 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. PLEASE PROVIDE AN ASBESTOS TEST REPORT FROM A CERTIFIED CDPHE ASBESTOS INSPECTION AGENCY. We will need this report prior to permit issuance. Please have all sheets wet stamped and signed by the licensed design professional. The architect �C may submit all new sheets or come into the office and stamp and sign the sheets we have in our office. zoi�oz9yy L&K Environmental Inc 1 ASBESTOS INSPECTION AND BULK SAMPLING REPORT Created For: Blake Romine SF Construction 7433 Indian Wells Cove Lone Tree, CO 80124 Project Name: Rocky Mountain Barrel Company 11467 West 170 Frontage Road North Wheat Ridge, CO 80033 Prepared By: Greg Bratton L&K Environmental Inc. Building Inspector# 23906 City of wheat Ridge Purpose of Inspection: On November 14, 2018 L&K Environmental had been contracted to perform a limited asbestos inspection and bulk sampling for suspect asbestos containing building material (ACBM). f the amount of ACM to be disturbed exceeds the following trigger levels, then an asbestos abatement contractor must remove the material: • Single -Family Residential Dwellings ("SFRD") - the trigger levels are: 50 linear feet on pipes; 32 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. • Public and Commercial Buildings (other than SFRDs) - the trigger levels are: 260 linear feet on pipes; 160 square feet on other surfaces; or the volume equivalent of a 55 -gallon drum. The purpose is to identify possible ACBM that is to be disturbed, determine the condition of suspect materials, and determine homogeneous areas where suspect materials are being tested. When sampling surfacing material, at least three samples must be collected for <1,OOOsq. ft., at least five samples for between 1,000 - 5,OOOsq. ft., and at least seven samples for >S,OOOsq. ft. When selecting sample locations, random sampling is done in accordance with the EPA pink book. Once samples have been collected they must be submitted for analysis. Exclusions: 1. A certified building inspector shall not be required to perform an inspection if based on prior records there has been sampling done and determined no ACM is present. 2. An architect or project engineer who was responsible for the construction of the building signs a statement stating that no ACM was used in any known building material. Laboratory Protocol: All bulk samples will be submitted to an independent NIST accredited NVLAP laboratory. Phase Light Microscopy will be used to analyze samples. All samples <1% will be point counted to determine exact asbestos composition. For each homogenous area samples containing <1% asbestos is considered not to contain asbestos if all samples collected show asbestos in this amount. If any samples within a homogeneous area are found to contain >1% the whole homogeneous area must be treated as asbestos containing. City of Wheat Ridge Lab Summary for Samples Collected on November 14, 2018: HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification Category 2 Main Room; CEO Office #7 —Any remaining friable ACM or friable suspected ACM. Classification HA in SF (Yes/No) Content Main Room; CEO Office SM 1-1 Drywall, Paint, Main Room, W Surfacing 880- Yes ND 1 Texture Facing Wall 900 SM 1-2 Drywall, Paint, CEO Office, S Surfacing 880- Yes ND Texture Facing Wall 900 SM 1-3 Drywall, Paint, CEO Office, N Surfacing 880- Yes ND Texture Facing Wall 900 HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) Content 2 MM 1-1 Drywall, Paint, CEO Office, N Misc. 880- Yes ND Texture, Joint Facing Wall 900 Compound (Corner) HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) Content 3 MM 2-1 Vinyl Cove Base, Main Room Misc. 80-90 No ND Mastic HA # Sample ID Material Description Sample Location Material Affected Friable Asbestos Classification HA in SF (Yes/No) Content 4 MM 3-1 Carpet, Mastic Main Room Misc. 500- No ND 600 Summary of Areas Included in HA & Classification Categories: HA # Included in HA Classification Category 1 Main Room; CEO Office #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 2 Main Room; CEO Office #7 —Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 3 Main Room; CEO Office #7 — Any remaining friable ACM or friable suspected ACM. HA # Included in HA Classification Category 4 Main Room; CEO Office #7 — Any remaining friable ACM or friable suspected ACM. Recommendations: All samples referenced above were collected on November 14, 2018. The materials/areas sampled on November 14, 2018 contained no asbestos. Removal of the suspect materials/areas may be done without abatement activities. _00 city of ' Wheat Ridge Signatory: Attached is the laboratory analysis report and technician certification(s). Please direct any questions or concerns regarding the information in this report to our office at 303-912-5016 and we will be happy to assist. Thank you for choosing L&K Environmental, Inc. Sincerely, Kevin Mackey L&K Environmental, Inc. Building Inspector# 13984 Attachments: Laboratory Analytical Data; Technician Certification(s) City of Wheat Ridge til eurofins CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for L&K Environmental CLIENT PROJECT: RMBC - 11467 W.I-70 Frontage Rd N Wheat Ridge, CO 80033 LAB CODE: Al 815142 TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORT DATE. 11/15/18 TOTAL SAMPLES ANALYZED: 6 # SAMPLES >1% ASBESTOS: City of Wheat Ridge tiff, eurofins CEI PROJECT: RM BC - 11467 W. 1-70 Frontage Rd N Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY Wheat Ridge, CO 80033 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 LAB CODE: A1815142 ASBESTOS Client ID Layer Lab ID Color Sample Description % SM1-1 Layer 1 A181265 White Texture/ Paint None Detected --------------------------------------------------------------- Layer 2 A181265 White,Tan Drywall None Detected SM1-2 Layer 1 A181266 White Texture/ Paint None Detected --------------------------------------------------------------- Layer 2 A181266 White,Tan Drywall None Detected SMI -3 Layer 1 A181267 White Texture/ Paint None Detected --------------------------------------------------------------- Layer 2 A181267 White,Tan Drywall None Detected MM1-1 Layer 1 A181268 White Texture None Detected --------------------------------------------------------------- Layer 2 A181268 White Joint Compound None Detected --------------------------------------------------------------- Layer 3 A181268 White,Tan Drywall None Detected MM2 -1 Al 81269A Black Covebase None Detected A181269B Tan Mastic None Detected MM3 -1 Layer 1 A181270 Gray Carpet None Detected --------------------------------------------------------------- Layer 2 A181270 Tan Mastic None Detected Cefyof W yi heat nl ✓tf�@ 1 of 1 eurofins ASBESTOS BULK ANALYSIS ti By: POLARIZING LIGHT MICROSCOPY r CEI Client: L&K Environmental Lab Code: Al 815142 9851 Castle Ridge Circle Date Received: 11-15-18 Littleton, CO 80129 Date Analyzed: 11-15-18 Date Reported: 11-15-18 Project: RMBC - 11467 W.I-70 Frontage Rd N Wheat Ridge, CO 80033 4SBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % SMI -1 Texture/ Paint Homogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A181265 Non-fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum None Detected A181265 White,Tan Fibrous Bound SMI -2 Texture/ Paint Homogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A181266 Non-fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum None Detected A181266 White,Tan Fibrous Bound SM1-3 Texture/ Paint Homogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A181267 Non-fibrous 5% Paint Bound ----------------------------------------------------------------- Layer 2 Drywall Heterogeneous 20% Cellulose 80% Gypsum None Detected A181267 White,Tan Fibrous Bound MMI -1 Texture Homogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A181268 Non-fibrous 5% Paint Bound City of Page 1 9t 3 e u rof i n s; ASBESTOS BULK ANALYSIS ti: By: POLARIZING LIGHT MICROSCOPY CEI Client: L&K Environmental Lab Code: Al 815142 9851 Castle Ridge Circle Date Received: 11-15-18 Littleton, CO 80129 Date Analyzed: 11-15-18 Date Reported: 11-15-18 Project: RMBC - 11467 W.I-70 Frontage Rd N Wheat Ridge, CO 80033 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % ---------------------------------------------------------------- Layer 2 Joint Compound Homogeneous 60% Binder None Detected A181268 White 40% Paint ------------------------------------------------------------------ Non-fibrous Layer 2 Mastic Homogeneous 100% Mastic None Detected Bound Tan -_--------w-----------------o-----------o---------------------- Layer 3 Drywall Heterogeneous 2010 Cellulose 80% Gypsum None Detected A181268 White,Tan Fibrous Bound MM2 -1 Covebase Homogeneous 100% Vinyl None Detected A181269A Black Non-fibrous Bound A181269B Mastic Homogeneous 100% Mastic None Detected Tan Non-fibrous Bound MM3 -1 Carpet Homogeneous 100% Synthetic Fiber None Detected Layer1 Gray A181270 Fibrous ------------------------------------------------------------------ Loosely Bound Layer 2 Mastic Homogeneous 100% Mastic None Detected A181270 Tan Non-fibrous Bound Oeurofins CEI LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORTING LIMIT: <1 % by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1 % by 1,000 Points REGULATORY LIMIT: >1 % by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBS) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling. ANALYST: i' APPROVED BY: Megan Fisher Tianbao Bai, Ph.D., CIH Laboratory Director NVkAo TES NVLAP LAB CODE 101768-0 City of eurofins 730 SE Maynard Road, Cary, NC 27511 Tel: 866-481-1412; Fax: 919-481-1442 CHAIN OF CUSTODY CEUP LAB USE ONLY. CEI Lab Code: M1 )'12' (1-1 .CEI Lab I.D. Range: Jq 11912 16 COMPANY INFORMATION PROJECT INFORMATION CEI CLIENT #: Job Contact: Kevin Mackey Company: L&K Environmental Email/ Tel: Lkenvironmental@gmail.com Address: 9851 Castle Ridge Cir Project Name:06�� -- )1" q&I& T-76 fi&11% Highlands Ranch, CO 80129 Project lD#: Email: Lkenvironmental@gmail.com PO Tel: 303-912-5016 Fax: STATE SAMPLES COLLECTED IN: CO IF TAT IS NOT MARKED STANDARD 3 DAY TAT APPLIES. ASBESTOS METHOD ULM- Accept Samples TURN AROUND TIME 4 HRI� 8 H I DAY 2 DAY 3 DAY 5 DAY PLM BULK EPA 600 ED" EJ 0 0 F-1 1:1 PLM POINT COUNT (400) EPA 600 0 1:1 1:1 D ID E] PLM POINT COUNT (1000) EPA 600 0 E] 0 0 EJ 0 PLM GRAV w POINT COUNT EPA 600 El El 0 ED 1:1 PLM BULK CARB 435 EJ Q 1:1 1-1 E] PCM AIR* NIOSH 7400 El 0 El Q D 0 TEM AIR EPA AHERA ED 1:1 1:1 El El EJ TEM AIR NIOSH 7402 1:1 11 ED El El 11 TEM AIR (PCME) ISO 10312 E] 1:1 El ID El Q TEM AIR ASTM 6281-15 1:1 El 0 1:1 TEM BULK CHATFIELD ❑ El 0 EJ E TEM DUST WIPE_ ASTM D6480-05 (2010) EJ El E] El D Q TEM DUST MICROVAC ASTM D5755-09 (2014) ❑ 0 Q El D E TEM SOIL ASTM D7521-16 E] EJ 0 El TEM VERMICULITE CINCINNATI METHOD 0 F-1 El D TEM QUALITATIVE IN-HOUSE METHOD EJ EJ 0 0 D OTHER: ❑ 0 0 F-1 D 0 *Blanks should be taken from the same sample lot as field samples. M, REMARKS / SPECIAL INSTRUCTIONS: ULM- Accept Samples E--] Reject Sa les 4 ciliz Relinquishqd By: Date/Time Received By: Dat 4Tiv).f,. 0, �"e ti is/ v k I Ing DivisonA (�//u ti eu rof i n s I SAMPLING FORM COMPANY CONTACT INFORMATION Company: Z-�G J—/ h�7/;r/,0)1;�/'f��tiv Job Contact: 2 Project Name: k—J' / C -1 �`� tU VT Project ID #: Tel: SAMPLE ID# DESCRIPTION / LOCATION VOLUME/ AREA TEST PLM TEM PLM E ' TEM 0 — - v PLM © TEM PLM TEM PLM TEM 0 l PLM TEM PLM 0 TEM PLM TEM 0 PLM TEM PLM TEM PLM 0 TEM PLM 0 TEM 0 PLM TEM PLM TEM 0 PLM TEM 0 PLM 0 TEM PLM TEM PLM 0 TEM PLM TEM 0 PLM TEM 0 PLM TEM PLM TEM PLM 0 TEM (� PLM TEM PLM TEM 0 PLM 0 TEM PLMTEM PLM 0 o f�. Page Version. CC0C.01. 3.L i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: I/M a F_T__ Job Address: / q� 7 t,// -7 �o Permit Number: �61Q, 0 / �/—7 ❑ No one available for inspectio Time I 0,/C1 AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 ff/ -1 Date: 7 �� / Inspector: DO NOT REMOVE THIS NOTICE �T� o ~CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: � q E F�lqlg u F �/ Job Address: 1067 �V _,T__'7o For! % /V Permit Number: ?o/ q ❑ No one available for inspection: Time,,) _�C__ AM/PM Re -Inspection required:Yes No When corrections have been made, call for re-inspelcctt-ion at 303-234-5933 Date: 7 �d 1 Inspector: ��t / / DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection 'Dfivision 3 (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:�i Job Address: d , V to % U) _Z_ `70 -r i? P46 IBJ Permit Number: ❑ No one available for inspection: TimeA/P Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: yam' l� Inspector: i3 DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE 10 Bailding Inspectior `Division TNk (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: TJINWO-11 '56.41((d Job Address: /1 Lf 47 W / - -7D r�-2 TcT w' 5,01-1 Permit Number: ZC511 '�-0l �-b % 1 ❑ No one available for inspection: Time ' gyp 1 � -� AM/PM .� Re -Inspection required:,,,/Yes, l No When corrections have been made, call for re -inspection at 303-234-5933 Date:_ 7`2q, 4 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: T4 c,\,j U 4 F_V-CA vkl Job Address: i I q (.o -7 W i - 7 0 (2d. Permit Number: 2 Cil F 1 '6 (-o 7 ❑ No one available for inspection: Time AMC Re -Inspection required: YesPN When corrections have been made, call for re -inspection at 303-234-5933 Date: —7, 10i A � Inspector: DO NOT REMOVE THIS NOTICE t i CITY OF WHEAT RIDGE Building -Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: (NSy (M ( Uyl Job Address: 1 14 (o UJ I - -7 C.) Permit Number: 201 �;y 1 irLo `7 ❑ No one available for inspection: Time `" A �M� Re -inspection required: Yes! I� When corrections have been made, call for re -inspection at 303-234- Date:- `7 ' (�f f k Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 DR - QOUfee-_ Cor, Job Address: 1)1-/4,-7- W =--7o Permit Number: 0 I 7 tW v Ll No one available for inspection: Time Z'q AWjM Re -Inspection required: Yes When corrections have been made, call for rye --inspection at 303-234- Date:- M %//a Inspector: 0-01 c4 DO NOT REMOVE THIS NOTICE City of Wheat Ridge Commercial Remodel PERMIT - 201801867 PERMIT NO: 201801867 ISSUED: 07/18/2018 JOB ADDRESS: 11467 W. I-70 Fr Rd N EXPIRES: 07/18/2019 JOB DESCRIPTION: Demo cold storage wall, install new 2x6 20 gauge steel wall; new wall, switching out lights, add drywall Type X on both sides of steel studs, add exits - 8,054 sq ft Tenant: The Barrel Company *** CONTACTS *** OWNER SIX OAKS PARTNERSHIP GC (303)888-2968 Mike Mueller 090040 Five Star Contracting LLC SUB (303)587-2049 Juell Seidel 110222 Seidel Electric LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 420 / Storage Warehouse; 0 BLOCK/LOT#: 0 / *** FEE SUMMARY *** Total Valuation Plan Review Fee Use Tax Permit Fee ** TOTAL ** *** COMMENTS *** ESTIMATED PROJECT VALUATION: FEES 0.00 112.19 159.64 172.60 444.43 7,602.00 *** CONDITIONS *** Approval from presiding fire department required prior to final building inspection sign -off. All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. City of Wheat Ridge ®- Commercial Remodel PERMIT - 201801867 PERMIT NO: 201801867 ISSUED: 07/18/2018 JOB ADDRESS: 11467 W. I-70 Fr Rd N EXPIRES: 07/18/2019 JOB DESCRIPTION: Demo cold storage wall, install new 2x6 20 gauge steel wall; new wall, switching out lights, add drywall Type X on both sides of steel studs, add exits - 8,054 sq ft Tenant: The Barrel Company I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable mun' i 1 codes, policies and procedures, and that I am the legal owner or have been authorized by the legal own of the prope and aut i to obtain this permit and perform the work described and approved in conjunction with this permit. ly t ized to include all entities named within this document as parties to the work to be perform a a r o isclosed in this document and/or its' accompanying approved plans and specifications. /7 Signature of OVINER r CONTRACTOR ( le one) Date I . This permit was issued fort a i rovided in thepermit application and accompanying Flans and specifications and is subject to the compliance wit a documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This, permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a perm t hall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code of o or finance egulation this jurisdiction. Approval of work is subject to f eld inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat icd �e COMMUNiTy DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its0ki.wheatridge co us FOR OFFICE USE ONLY Date: Plan/Permit # k 1 l % Plan Review Fee: ( �, Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: _ l 1 `16 % _LZ lis / l - ? 71�n (A Property Owner (please print): k [4,11,r_�e J I° f 4-i c-; / D PhoneJb_ (f 23 cl' Property Owner Email: Tenant (Commercial Projects Only) _ `//tt� hi�,��►t,Gt�=.� Property Owner Mailing Address: (if different than property address) Address: MG 7 jjz j � /-70 ) X11+4 cV 1,�,34r f 410 City, State, Zip: ��' . f j`< l p�G� 6, P-, [ Arch itect/Engineer: Pli/ s�-��� 1 /y •t LLQ Architect/Engineer E-mail: L-6 f;, i� fTA r co �?G` j Phone: (,j ,nom Contractor: �LLC, City of Wheat Ridge License #: ,_n� (000 ( v Phone: 303 ?'S Contractor E-mail Address: 1411 �C,2_Wt 1r_- 5",(A r' C0 C n 0 C p m For Plan Review Questions & Comments (please print): CONTACT NAME (please print): b�tl l ` - 14 l k F-- J J C (- Phone: -3 0 3 Z- 6 CONTACT EMAIL(p/ease print):__M1 LC Sub Contractors (Must provide Wheat Ridge License No.): Electrical: Plumbing: W.R. Cit License# W. R. City License# ,�---� 0cI, C,O.M Other City Licensed Sub: Other City Licensed Sub: City License # i 1 (:D �'� '2- City License # Mechanical: W. R. City License # ®'COMMERCIAL ❑ RESIDENTIAL Description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance, size and efficiency, type and amount of materials to be used, etc, S/It ��i r'% �rri // c>✓ z G Lfi:_s j!� _ffvt� G✓• l/ ��ry {k �J -�l behatee, . 4c,ti, `s �;.• GC �l<.3" l✓/� 7�-. t �', f�/ia [.f ;-7'Li+, �t � �( /� G` � f � �`� 9d ���e-mss i;�f y�"'�``Ll /Yp X S�o s� d f .ffzs -A Commercial Projects Only: Occupancy Type: Construction Type:_ Sq. Ft./LF J L S� BTUs Amps Squares Gallons Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided -on -the application. CIRCLE ONE: (OWNER) X M4rTAOR PRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first andlastnna e):W- DATE: Printed Name: !11ke ZONING COMMMENTS: Reviewer. BUILDING DEPARTMENTCO MENT Reviewer. t PUBLIC WORKS COMMENTS: Reviewer. DEPARTMENT USE ONLY '75v Sr Cx�`�10 I�( "x,�,T OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE:---. — -7/ 6oZ IBuilding Division Valuation: 7� 60-Z 1 Print Preview o!� Permit Application - Print Preview Addr/Street: 11467 West Interstate 70 Frontage Road City/State: Wheat Ridge CO Zip Code: 80033 First Name: Last Name: Business Name: Six Oak Limited Partnership Phone: 303 423 9700 Phone AH: Cell Phone: Fax: Addr: 11457 West 1-70 Frontage Road North Suite: City/State: Wheat Ridge CO Zip Code: 80033 Email: Kirbykunz@comcast.net Building: Occupant: The Barrell Company Suite: Property Use Type: Commercial Job Type: Tenant Finish/Remodel Sq Ft: 750.00 Cost: $7,000.00 Desc: Remove wall in the cold storage area at 11467 and combine it with the cold storage unit from unit 11457. Build a new 2x6 wall from the ground to the deck above to create a 2 hour separation. 2 layers of 5/8" type X rock on both sides taped and finished. No electrical in the new wall. Existing lights will be switched from the 11467 side. Insulate new wall. Add Emergency existing per drawing. Comments: https://www.mobile-eyes.com/PA_PrintPreview.a.sp Page 1 of 1 6/26/2018 Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 LIMITED ASBESTOS INSPECTION REPORT 11467 11467 170 Frontage Road North Wheat Ridge, CO 80033 0 Report Date: June 23, 2014 Inspection j Testing Date: June 19, 2014 Enviro File: 1406-24 Prepared by: Scott Pfeffer Colorado Certified Asbestos Building Inspector, 20333 Mold Assessor and Inspector Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 Limited Scope of Report The asbestos inspection performed for client was designed to identify suspect asbestos containing building materials in the affected areas of the above -referenced subject property as they existed at the time of the inspection. The inspection was limited to those areas that were visually and physically accessible. The inspection was not a risk assessment, physical inspection of systems, structure, or components of the subject property, as it relates to their serviceability. The inspection was performed in accordance with the Standards of Practice of the Colorado Regulation 8 Part B in effect at the time of this Inspection. This inspection is not intended to be technically exhaustive. The Inspector has prepared this written asbestos Inspection Report for the sole use and benefit of the client. The asbestos inspection report shall identify, report, and make recommendation for future evaluation. Client agrees to read the entire asbestos inspection report when received and shall promptly call the inspector with questions or concerns regarding the report. The use of this report and information contained herein by others, in whole or in part, is not authorized without the written mutual consent of the client and Enviro Excellence Consulting and Testing (Enviro Excellence). Purpose and Scope The purpose of this inspection was to conduct a visual asbestos inspection and to collect necessary samples in order to determine the presence or absence of asbestos within the subject property in the affected areas only. The scope of this report included a visual inspection of all affected rooms and/or areas throughout the subject property for visible suspect ACM (asbestos containing materials). This does not include any materials that were covered or hidden by walls, structures, carpeting, wood flooring, multiple layers, wallpaper, texturing, etc. However, the Inspector made every reasonable effort to access and identify all suspect ACM. Bulk asbestos samples were randomly collected from homogenous areas of suspect ACM by the above named Inspector, an EPA/State of Colorado Certified Asbestos Inspector. Homogenous areas are defined as any area with the same material, texture, and color. If any of these variables differs between materials or if for any reason the inspector feels the materials might be different in any respect (such as materials being installed at different times even though they appear similar), separate sets of samples must be taken from each homogenous area. Representative bulk samples were taken from similar materials but this does not guarantee that materials of similar appearance are of the same composition. Even similar materials are subject to uneven mixing and distribution and random sampling can miss ACM. Enviro Excellence used reasonable diligence and its professional judgment consistent with industry standards in order to identify all suspect ACM. Performance of this asbestos inspection is intended to reduce, but not eliminate, uncertainty regarding the presence of ACM in connection with the above referenced property. No guarantee expressed or implied. Enviro Excellence cannot be held accountable for restrictions placed on us by the client, conditions or information that remain unknown, or areas that were inaccessible at the time of the inspection. Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 Bulk Samples were analyzed by Polarized Light Microscopy (PLM) in general compliance with guidelines established by the US EPA (40 CFR Part 763, Subpart F, Appendix A). Asbestos concentrations were visually estimated and/or point counted by the laboratory and reported in percent for each layer of the sample. The assessment was executed in accordance with the authorized scope of work. If the scope of work is changed, the inspector must be informed and an addendum made to this report. This report is solely a record of activities, observations, analytical results, and recommendations performed to date. Regulatory Review EPA and the Colorado Department of Public Health and Environment (CDPHE) regulate all building materials that contain greater than 1% asbestos as determined through PLM Analysis. OSHA regulates all building materials that contain smaller amounts of asbestos (even trace concentration as determined by PLM analysis). EPA and CDPHE Regulation No. 8, Part B, requires that suspect ACM in buildings built prior to 1988 be assumed to be asbestos or an inspection be conducted prior to demolition or remodeling activities that could disturb ACM. However, with the North American Free Trade Agreement in effect and trade with countries such as Canada, Mexico, and China, it can never be determined that a material is not asbestos containing (even if it was produced after 1988) unless it is tested by a certified state inspector. The EPA and CDPHE require all friable and non -friable ACMs in the affected area(s) be removed prior to renovation activities that may disturb the ACM, and all friable ACM must be removed prior to demolition. Removal or management of regulated ACM is only required if they may be damaged or disturbed during remodeling, demolition, or burning. In some circumstances, "point count" analysis is required for bulk samples previously analyzed by PLM. Point counting is a more detailed means of analysis that standard PLM. Federal and State agencies define ACM as materials containing greater than 1% asbestos. The NESHAP regulation requires that if standard PLM analysis determines that a sample contains less than 10% asbestos, the material must be considered asbestos containing or be point counted. Even if the sample is less than 1% by standard PLM, the material either has to be assumed to be ACM or point counted. If the point counting analysis is different than the PLM analysis, the point counting results take precedence over the PLM. If standard PLM analysis determines that a material has no asbestos or that the material contains greater than 10% asbestos, point counting is not necessary. Background The inspector was called to the subject property by Kirby Kunz of five K. Investments Company/Six Oak Limited Partnership. Mr. Kunz was concerned about asbestos containing building materials in the affected areas of the building. Per Mr. Kyunz suspect asbestos containing building materials to be disturbed in the scope of work include: The affected materials sampled - Drywall - Ceiling Tile - Vinyl Cove Base - Vinyl Tile Flooring - Glue down Carpet Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 The affected areas include: - Front Offices - Warehouse The affected areas as defined by the scope of work are limited to those listed above. If the scope of work is to change at any point, the inspector must be called back to the property to do additional testing. Sampling The Inspector determined that it was necessary to collect 26 bulk sample(s) from the various homogenous areas (see the Asbestos Sampling below for exact areas). All samples were submitted to an accredited third party independent laboratory. The laboratory results are incorporated into this report. HOMOGENEOUS AREA LIST 7-- o Texture, Drywall Tape, Joint Compound, Drywall Surfacing- Friable- Not Damaged 1776sgft 02 Texture, Drywall Tape, Joint Compound, Drywall Wall Surfacing- Friable- Not Damaged 1300sgft 03 Ceiling Tile Painted Ceiling Misc.-Friable-Not Damaged 289sgft 04 Ceiling Tile White/Gray 7Wall Ceiling Misc.-Friable-Not Damaged 2508sgft OS Vinyl Cove Base, Mastic Wall Misc.-Not Friable -Not Damaged 7201f 09 Texture, Drywall Tape, Joint Compound, Drywall Wall Surfacing- Friable- Not Damaged 4560sgft 07 Texture, Drywall Tape, Joint Compound, Drywall Wall Surfacing- Friable- Not Damaged 1224sgft 08 Vinyl Flooring Tile, Mastic Floor Misc.-Not Friable -Not Damaged 102sgft Asbestos Testing Results (Samiples in RED are asbestos Containing) Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 24-1-01 1 01 A' � a Texture, white cream r r Office right hallway '� e• r ND 24-1-01 2 01 Drywall tape, beige Office right hallway ND 24-1-01 3 01 Joint compound, beige Office right hallway ND 24-1-01 4 01 Drywall, off white/brown Office right hallway ND 24-1-02 1 01 Texture, white cream Open area North end West wall ND 24-1-02 2 01 Drywall tape, beige Open area North end West wall ND 24-1-03 1 01 Texture, white cream Office North East comer East wall ND 24-1-03 2 O1 Drywall tape, beige Office North East corner East wall ND 24-1-03 3 01 Joint compound, beige Office North East comer East wall ND 24-1-03 4 01 Drywall, off white/brown Office North East comer East wall ND 24-1-04 1 01 Texture, white cream Large center office West wall ND 24-1-04 2 01 Drywall tape, beige Large center office West wall ND 24-1-04 3 01 Joint compound, beige Large center office West wall ND 24-1-04 4 01 Drywall, offwhite/brown Large center office West wall ND 24-1-05 1 01 Texture, white cream Large center office East wall ND 24-1-05 2 01 Drywall tape, beige Large center office East wall ND 24-2-06 1 02 Texture, white cream Left office with painted ceiling ND 24-2-06 2 02 Drywall tape, beige Left office with painted ceiling ND 24-2-07 1 02 Texture, white cream Men's room beside urinal ND 24-2-07 2 02 Drywall tape, beige Men's room beside urinal ND 24-2-08 1 02 Texture, white cream Women's room beside toilet ND 24-2-08 2 02 Drywall tape, beige Women's room beside toilet ND 24-2-08 3 02 Joint compound Women's room beside toilet ND 24-2-08 4 02 Drywall, off white/ brown Women's room beside toilet ND 24-2-09 1 02 Texture, white cream Small closet in left office with paint ceiling ND 24-2-09 2 02 Drywall tape, beige Small closet in left office with paint ceiling ND 24-2-09 3 02 Joint compound Small closet in left office with paint ceiling ND 24-2-09 4 02 Drywall, off white/ brown Small closet in left office with paint ceiling ND 24-2-10 1 02 Texture, white cream Left office with painted ceiling North wall ND 24-2-10 2 02 Drywall tape, beige Left office with painted ceiling North wall ND 24-3-11 2 03 2x4 Ceiling panel, white/ gray Painted blue Left office with painted ceiling ND 24-4-12 1 04 2x4 ceiling the 2x4 Ceiling panel, white/ gray Entry area ND 24-4-13 1 04 2x4 ceiling tile 2x4 Ceiling panel, white/ gray Open area offices center North ND 24-4-14 1 04 2x4 ceiling the 2x4 Ceiling panel, white/ gray Middle office East side North end ND 24-5-15 1 05 Cove base, it. gray Small closet in left office painted ceiling ND 24-5-15 2 05 Cove base mastic, beige Small closet in left office painted ceiling ND 24-5-16 1 05 Cove base, It. gray First office to the right in corner behind door ND 24-5-16 2 05 Cove base mastic, beige First office to the right in comer behind door ND 24-5-17 1 05 Cove base, It. gray North office East wall ND 24-5-17 2 05 Cove base mastic, beige North office East wall ND Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 24-6-18 1 06 Texture white Warehouse tall wall East wall left l i e ND 24-6-18 2 06 Drywall, off white/brown Warehouse tall wall East wall left ND 24-6-19 1 06 Texture white Warehouse tall wall East wall left ND 24-6-19 2 06 Drywall, off white/brown Warehouse tall wall East wall left ND 24-6-20 1 06 Texture white Warehouse tall wall South wall ND 24-6-20 2 06 Drywall, off white/brown Warehouse tall wall South wall ND 24-6-21 1 06 Texture white Warehouse tall wall North wall ND 24-6-21 2 06 Drywall, off white/brown Warehouse tall wall North wall ND 24-6-22 1 06 Texture white Warehouse tall wall North end East wall ND 24-6-22 2 06 Drywall tape, beige Warehouse tall wall North end East wall ND 24-6-22 3 06 Joint compound Warehouse tall wall North end East wall ND 24-6-22 4 06 Drywall, off white/brown Warehouse tall wall North end East wall ND 24-7-23 1 07 Texture, white/ cream Back wall short South end ND 24-7-23 2 07 Joint compound, beige Back wall short South end ND 24-7-23 3 07 Texture, white/ cream Back wall short South end ND 24-7-23 4 07 Drywall, off white/brown Back wall short South end ND 24-7-24 1 07 Texture, white/ cream Back wall short Middle ND 24-7-24 2 07 Joint compound, beige Back wall short Middle ND 24-7-24 3 07 Texture, white/ cream Back wall short Middle ND 24-7-24 4 07 Drywall, off white/brown Back wall short Middle ND 24-7-25 1 07 Texture, white/ cream Back wall short North end ND 24-7-25 2 07 Drywall, off white/brown Back wall short North end ND 24-8-26 1 08 Floor tile, white Warehouse closet ND 24-8-26 2 08 Floor tile mastic, yellow Warehouse closet ND Conclusion Asbestos containing building materials WERE NOT found in the samples analyzed by the laboratory. The affected building materials DO NOT need to be removed by a certified abatement company. Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 Enviro Excellence assumes no liability for any loss, injury, or claim for damages arising directly or indirectly from any use or reliance on this report or the opinions expressed herein. Enviro Excellence makes no risk assessment, warranty, guarantee or insurance policies of any kind, express or implied. This report is limited only to the samples taken and locations sampled. There are no risk assessments, warranties, guarantees, or insurance available or provided by Enviro Excellence. Additional sampling may be needed to further identify other pollutants, or other mold/fungus affected areas inside the subject property. This report was prepared pursuant to the contract Enviro Excellence has with the client. That contractual relationship included an exchange of information about the subject property that was unique and between Enviro Excellence and its client and serves as the basis upon which this report was prepared. Because of the importance of the communication between Enviro Excellence and it's client, reliance or any use of this report by anyone other than the client, for whom it was prepared, is prohibited and therefore not foreseeable to Enviro Excellence. No warranty is made. Enviro Excellence's liability and that of contractors and subcontractors arising from any service rendered hereunder shall not exceed the total fee paid by the client to Enviro Excellence. Thank you for the opportunity to work with you on this project. Please call at 303.589.2735 with any questions or concerns. Thank you. Sincerely, Scott Pfeffer Enviro Excellence Consulting and Testing Colorado State Certified Asbestos Inspector, 20333 Mold Assessor and Inspector Mitigation Specialist Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 Additional Risk Pictures HA 01 HA 02 Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 HA 04 HA 05 Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 HA 06 HA 07 Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 HA 08 Enviro Excellence Consulting and Testing 7241 Red Mesa Ct, Littleton, CO 80125 303.589.2735 OF co, fc 0 h �•, o • Colorado Department of Public Health and Environment ASBESTOS CERTIFICATION* This certifies that Scott Pfeffer Certification No.: 20333 has met the requirements of 25-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part 13, and is hereby certified by the state of Colorado in the following discipline: Building Inspector* Issued: Apra 05, 2014 Expires: April 05, 2015 -This eerlifirare is rrdid n i/y n•itlr the parsmhm nja enrrenr I)irision-apprnred rruiulug rnnrre rerriJlenriuu f _ . is rhe discipline speeifred alwre. A :noezed APCti Representative SEAL Enviro Excellence Consulting and Testing 7241 Red Mesa Ct. Littleton, CO 80125 303.589.2735 a, o, 44 b � m Enviro Excellence Consulting and Testing 7241 Red Mesa Ct Littleton, CO 80125 Bill To Five K. Investments CO Six Oak Limited Partnership t 1457 W. 1-70 Frontage Rd. North Wheat Ridge, CO 80033 Invoice Date Invoice # 6/23/2014 1406-18A-24 P.O. No. Terms Project Kirby K Due on receipt Quantity Description Rate Amount Units 11465/11467 30 samples in 11465 26 samples in 11467 Asbestos Inspection by certified building inspector includes three samples 400.00 400.00 53 Additional samples required to complete survey inspection 36.00 1,908.00 Any questions with this invoice please contact Scott PfefTer at 303.589.2735 Total $2,308.00 Certificate Of Completion Building Division 7500 W 29TH AVE WHEAT RIDGE CO 80033-8001 Permit#:201401023 Issued: 08/22/2014 Stipulations: Interior Remodel - Walls, Ceiling, Electrical, HVAC and Plumbing. This certificate verifies that the building constructed and/on the use proposed of the building and/or premises, under t above permit number and on property described below, does compl with the Wheat Ridge Building Code and development standards the zone district in which it is located and may be occupie All other licensing requirements for the City must be met. I Owner: SIX OAK LIMITED PARTNERSHIP 11467, W. 1-70 FR. RD. NORTH WHEAT RIDGE, CO 80033 Contractor: Mike Mueller 16935 W 48TH PL GOLDEN CO 80403-1620 For the Following Purpose: Comm. Tenant Finish Code 3-tions NO change shall be made in the USE of 2 ICC/2014 NEC this building without prior notice 2006 ICC/2011 NEC and a new Certificate Of Completion 2006 ICC/2005 NEC from the City of Wheat Ridge. Other Nil (Jtv of W h 61 at c 11 cyc 1 1111111 1 11111 1 11111 11 l I !!!!!I 7 A P�0 M� Addre ss.- 0 I t. Phone: 3 C) ElectIll - W R, City License Plumbill F N R W, R, City Ucense Mechanical: J !"B Kar,441 WR C4 Ucense # Other City Licensed Sub City License # Other City Ucensed Sub: City License # Complete all information on BOTH sides of this for -a- S% FULF !Z3L 4 Amps 2,0 0 §- 1 0' ,) A L l Squares Other Building Division Valuation: tits Wh6at R�� F OR OFFICE USE ONI, Y I Building Permit Application ii I iji 1 m 1 11 Address: 11q, tAj t� 4 trcl 2�11,d w I- U01Jv,�J111,1- I in Electrical: - k t d W.R. City License Other City Licensed Sub; City License # Plumbing: F tj W.R. City License Other City Licensed Sub: City License # Mechanical: T1,+ WR City License Complete all information on BOTH sides of this form A"Wo l NEW COMMERCIAL STRUCTURE SERVICE NEW RESIDENTIAL ROOFING OMMERCIAL ADDITION RESIDENTIAL ROOFING RESDENTIAL ADDITION H WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ACCESSORY RESIDENTIAL .r: shed, deck, MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYST e,, ` t f to Sq. FULF Amps Btu's Squa Buildin D ivision 11467 WEST 1-70 FRONTAGE ROAD NORTH. WHEAT RIDGE, COLORADO 80033 a s 0 Mv City of Wheat idge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033 -8001 P: 303.235.2846 F: 303.235.2857 May 8, 2014 OFFICIAL ADDRESS NOTIFICATION (ZIP CODE CORRECTION) NOTIFICATION is hereby given that the following address has been assigned to the property /properties as indicated below: PROPERTY OWNER(S): Six Oak Limited Partnership OLD ADDRESS: 11465 W. I -70 Frontage Rd. N. Wheat Ridge CO 80033 NEW ADDRESS: 11467 W.1 -70 Frontage Rd. N., Wheat Ridge CO 80033 (additional address) SUBDIVISION: Wheat Ridge Industrial Park LOT(s): 08 KEY: SECTION: 16 PARCEL NO: 39- 163 -03 -005 NOTES: This is a courtesy notification. AUTHORIZED BY: DATE: -is- g DISTRIBUTION: 1. Property Owner 2. Jefferson County Assessor, ATTN: Data Control, 100 Jefferson County Parkway, Golden, 80419 3. Jefferson County Mapping, ATTN: Addressing, 100 Jefferson County Parkway, Golden, 80419 4. Jefferson County Elections, ATTN: S. Stormer, 3500 Illinois Ave., Laramie Building, Suite 1100, Golden, CO 80401 5. Jefferson County Elections, ATTN: H. Roth, 3500 Illinois Ave., Laramie Building, Suite 1100, Golden, CO 80401 6. U.S. Post Office, 4210 Wadsworth Blvd., Wheat Ridge, CO 80033 7. Xcel Energy, ATTN: Correspondence, 1123 W. 3` Ave., Denver, CO 80223 8. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 9. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 10. Valley Water District 11. Fruitdale Sanitation District 12. Arvada Fire Department 13. Wheat Ridge Planning Division 14. Wheat Ridge Building Division 15. Wheat Ridge Police Department 16. GIS Specialist 17. Log File 18. Other: NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: DATE: www.d.wheatridge.coms Vicinity Map Site ti �4' r CITY OF WHEAT RIDGE Building Inspection Division (303),234-5933 Inspection line (303) 235 -2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type Rkr Job Address //W 7 ft,,. 7 7r� : �✓. Permit Number //_:z2 ;r q t s ❑ No ne available for inspection: Time :w MOW pection required: Yes ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: L7f/~tl~~ e~.z✓ Job Address: r`;'• RC>° t/' Permit Number: 070/ 1 ❑ No one available for inspection: Time AM/PM Re-Inspection required: Yes No "When corrections have been made, calf for re-inspection at 303-234-5933 Date: ✓s~Zr`~ Inspector: C~! DO NOT REMOVE THIS NOTICE 41 City of Wheat Ridge 1r- Commercial Demolitio PERMIT 090191 PERMIT NO: ' 090191 ISSUED: 03/10/2009 JOB ADDRESS:` 11467 W. I-70 Fr Rd N EXPIRES: 09/06/20.09 DESCRIPTION:: Remove walls for larger assembly ***:CONTACTS owner SixOak Limited gc 303/888 29:68 Mike Mueller 09-0040 Five Star Contracting LLC **.'PARCEL: INFO ZONE CODE: UA USE: UA SUBDIVISION: 0055 `BLOCK/LOT#: 0/ **iFEE SUMMARY ESTIMATED PRO MLATION: .00 . FEES Demolition Fee .5.0.00. **;TOTAL 50.00 Conditions: Subject to field inspections. Turn in plans to Arvada Fire. Approval required before final is passed. I hereby certify that the setback distances proposed by this permit application:. are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions.. of record;.;. that all measurements shown, and allegations made are accurate; that I have read and agree to abide: by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other.. applicable Wheat e O dinances,> rk under this permit Plans subject tofield inspection - ig 'l date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the city.;. 2. This permit shall expire 180 days from the issue date.. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires_a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year :If changes. have been or if suspension or abandonment' exceeds one (1) year, full fees shall be paid for a new permit 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify.. the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive:. written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor.'. an lapproval of, any violation of the provisions of the building codes or any other ordinance, law;.: rule or regulation. All plan review is subject o field inspections. Signature of Chief Bu' fficial ?date INSPECTION RE ST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REOUESTS MUST E.:MADE BY '3PM ANY RUSTNESS T)AY FOR TNSPF('TTON THE EOILOWTNG RiISINERS DAY. COMMUNITY DEVELOPMENT DEPARTMENT of wNegTP BUILDING INSPECTION LINE - 303.234-5933 o~ CITY OF WHEAT RIDGE m 7500 WEST 29TH AVENUE WHEAT RIDGE, CO 80033 - (303-235-2855) `t'~o??pO° APPLICA Property Owner: S,x 0r tr- f iM,t<k Property Address: / f q&,-7 P-1 r' 7 v n. < Contractor License No.: Company: 6.,_ r At r I OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I BI 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under thi~,~d. Plans sl~rjj,W to field inspection. (OWNER)(CONTRACTOR): SIGNED/y/• (OWNER)(CONTRACTOR):PMNTED ' ' ' /`T- /;;'/a ezll( DATE Building Permit Number: Date: Phone: Phone: 30 3- $8- 8.7-`)(, 8 Valuation Figure; $ - Value:$ Permit Fee:$ Plan Review Fee:$ Use Tax Total:$ Use of Space (description):_e Description of work: jZa o. cvl sr l~ ~yL ~sf. Sq. Ft. added Expiration Date; Expiration Date: :Expiration Date; A roval: A . roval: A roval: (1) This permit was issued in accordance with the{provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. (2) This permit shall expire if (A) the work authorized is not commenced within sixty (90) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. (3) If this permit expires, a new perk may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension orabandonment exceeds one (1) year, full fees shall be paid for anew permit. (4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem. (5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. (6) The issuance of a perk or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subject to field inspections. Chief Building Official Electrical License No: Plumbing License No: Mechanical License No: company: WIl\mc,- ~Ia cwc Company: Company: , ~I 7o FR 41V A 61£ ROAD Al ocK _I1 = ~~~fl~ 72s•~~;~ G 80033 i" i ~2 Li r; - ss LOADING DOCK ,a i u