Loading...
HomeMy WebLinkAbout2835 Ames Streeti CITY OF WHEAT RIDGE _:�9�Building Inspectiort Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE r Inspection Type: � n 1 - c�o v o g _- Job Address: "a S 3 s A ,n_lc_l 47 Permit Number: -P o 14i o -d S` -7 / N o Sg4-i e-- rC, I !nl o s- )c Cj e ne ❑ No one available for inspection: Time / 0 = 31(AM PM Re -Inspection required: Yes to When corrections have been made, call for re -inspection at 303-234-5933 Date:-/ q IV Ll / S Inspector: -T-b DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTIF_oc 4-! D 3- �— na I Inspection Type: -S/0- 'E) ec. dyl e lc r- k e tee -, f e Job Address: ' `a' 3S 8 rhes 4 - Permit Number: 2 0/ q 0 2 S" `7 I ❑ No one available for inspection: Time A PM Re -Inspection required: Yes `.,�) When corrections have been made, can fore -inspection, at 303-234>io_pq-5933 A Dat" Inspector: i DO NOT REMO E THIS NOTICE W City of Wheat Ridge Residential Solar PERMIT - 201802571 PERMIT NO. 201802571 ISSUED: 10/11/2018 JOB ADDRESS: 2835 Ames St EXPIRES: 10/11/2019 JOB DESCRIPTION: Residential solar-2.88kw solar PV roof mount system. *** CONTACTS *** OWNER (309)825-6536 KOSSMAN, NICK SUB (844)727-6527 :DaIMI Raichart 160040 Photon Brothers *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,000.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, appllicabble building codes, and all applicable munici al codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the pro erty and am aa�utizedoo tobtain this permit and perform the work described and approved in conjunction with this permit. I further attes at I a Bgally include all entities named within this document as parties to the work to be performed a at b ertorme losed in this document and/or it accompan ' g approved plans and specifications. Nis (.�� WAY -2, /�-0/'- Signature of ER r TRACTOR ( ' cle one) Date 1. This pe it was ' sue se ation provided in the permit application and accompanying plans and specifications and is subject to the Rance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit sha expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable � or any ordi*ice or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of RECEIVED Wheat Ridge COMMUNITY DEVELOPMENT SEP f 0 Building & Inspection Services Division Pe 7500 W. 29'h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 ' Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(cDci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: Plan/Permit # d -VI D / Plan Review Fee: Building Permit Application '*` Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ' Property Address: 2835 Ames St Property Owner (please print): Nick Kossman Phone: 309-825-6536 Property Owner Email: Mailing Address: (if different than property address) Address: 2835 Ames St City, State, Zip: Architect/Engineer, Arch itect/Eng1neer E-mail: Contractor: Photon Brothers Phone: Contractors City License #: � C (f)L( 6) Phone: 303-513-9269 Contractor E-mail Address: nick@photonbrothers.com e,0A-4 U/_ Sub Contractors: Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING RESDENTIAL ADDITION WINDOW REPLACEMENT COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 5�-6� i vnotihl SyS�ew. Sq. Ft./LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) S-UUd,cA:) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record: that all measurements shown and allegations made are accurate: that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application: that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. CIRCLE ONE. (OHINER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) ofOWNER) (CONTRACTOR) PRINT NAME: A y64n1%,A0 SIGNATURE: DATE: DEPARTMENT UW6Nt y ZONING COMMMENTS OCCUPANCY CLASSIFICATION Reviewer TYPE OF CONSTRUCTION BUILDING DEPARTMENT COMMENTS Reviewer PUBLIC WORKS COMMENTS Reviewer PROOF OF SUBMISSION FORMS Fire Department ❑ Received ❑ Not Required Water District ❑ Received ❑ Not Required Sanitation District ❑ Received 0 Not Required SPRINKLERED OCCUPANT LOAD Building Division Valuation: $ GODWIN ENGINEERING AND DESIGN, LLC 4732 Nichols Creek Road, Milton, FL 32583 1 (850)712-4219 1 chaditgodwineng.com September 18, 2018 To: City of Wheat Ridge Building Permits RECEIVED 7500 W. 29th Ave Wheat Ridge, CO 80033 SEP % 0 N I P, Ph: (303) 235-2876 F'e4� Re: Kossman Residence - Roof Mount PV Installation 2835 Ames Street Wheat Ridge, CO 80214 Plans Examiner, This letter is regarding the installation of a new roof mounted Solar PV system on the existing residential structure at the address above. I have analyzed/reviewed the attached plans and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the City of Wheat Ridge: 2012 International Building Code, IBC 2012 International Residential Code, IRC ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures 2017 National Electrical Code Per 2015 IBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V.it) - 110mph 3sec gust, Ground Snow load(P,) - 30psf, Exposure Category - C The PV System consist of PV modules, railing, and connection hardware. The system will add a dead load of approximately 3 psf to the roof. The existing roof structure consist of 2" x 6" rafters at 24" O.C. The existing structure will be adequate for supporting the additional PV dead load, snow and wind loads. The securement method of the PV system is to be flush mounted to the asphalt shingle roof with Sunpower Invisimount flashings/attachments. The flashings/attachments are the Sunmodo EZ Standoffs. The standoffs can be attached up to 72" apart and should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The standoffs shall be installed with a min. 5/16" lag screw with minimum 2-5/16" thread length. Please note that only a portion of the roof structure was reviewed. The engineer of responsible charge shall not be responsible for any existing flaws and/or defects that may currently exist or may be caused by the proposed installation. (',ity Oy Please contact me if you have any questions. Poo r,icF�s Com;\E C• Sincerely, 52767 Z' D. Chad Godwin, PE 52767 Exp. 10/31/2019 90 ;•� �SS�ONAL ENG Wheat Ridge Donnie C 0- Godwin G;101"09 M& 11:04:16 -05'00' F, LTJ C F G KOSSMAN PV PROJECT - 2.88 kWdc PROPERTY ASSESOR MAP - PROJECT LOCATION 1 NTS SCOPE OF WORK THESE PLANS ARE FOR THE INSTALLATION OF A ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM. THE PV SYSTEM WILL BE INTERCONNECTED WITH THE XCEL UTILITY GRID THROUGH EXISTING ELECTRICAL EQUIPMENT AND WILL OPERATE IN PARALLEL VIA LOAD SIDE CONNECTION WITH NET ENERGY METER. GOVERNING BUILDING CODES 1. 2012 INTERNATIONAL BUILDING CODE, IBC 2. 2012 INTERNATIONAL RESIDENTIAL CODE, IRC 3. 2012 INTERNATIONAL FIRE CODE, IFC 4. 2017 NATIONAL ELECTRICAL CODE, NEC 5. IEEE 1547 6. ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES 7. UL STANDARDS 7.1. RACKING - UL 2703 7.2. PV MODULE - UL 1703 7.3. INVERTER - UL 1741 DESIGN SPECIFICATIONS 1. AHJ - CITY OF WHEAT RIDGE 2. UTILITY - XCEL 3. BUILDING RISK CATEGORY II 4. DESIGN WIND SPEED (ULT) - 110 MPH 5. DESIGN SNOW LOAD - 30PSF 6. EXPOSURE CATEGORY - C 7. MEAN ROOF HEIGHT - 30 8. ROOF SLOPE - 23° f8 14, -:4-,,. W�xn .,.. BERKELEY W.,.A.< e Mountain - m View H t2) Wheat Ridge Olinger Crown 02835 Armes Street PV SYSTEM SPECIFICATIONS GLOSEVILLE W :.. A.. Co Forney M SUNNYSiDE of Transpc w+•;, a,. 8 RIVER NO ART DISTI HIGHLAND Hill Mortuary W.a^+>= ^"°•- '�F, Coors Field CURTIS Crown & Cemetery Hill Park w 1tat' A" Edgewater Downtown Aquarium � � rt D o s°•<FIVE P~ Pepsi Center - Sloan's Q t anmer Square take Park �y Mlle High Stadium Q�' r WEST COLFAX Denver i' J •€ .:aa a.. w:wn a.< - wino v.. � �`-� LINCOLN PARK u _ CAPITO I a,., n:, Denier Health (t } 6th Ave s}' Denver CC BAKER z � M>m data t20t8GoocN Unrced States=Terms SerM reedbatk 2 AERIAL MAP - PROJECT LOCATION L RTS RECEIVEI.- Sheet Index �f�1 1. PV MODULE: 9 xSPR-E18-320-DC; 2.88 kWdc SEP 2 0 Sheet Number 2. INVERTER: SOLAREDGE SE3000H-US PV01 3. RACKING: INVISIMOUNT BPV02 4. ROOF TYPE -SHINGLE 5. AZIMUTH:90,180 PV03 PV04 PV INSTALLATION OVERVIEW ELECTRICAL PV05 a. POINT OF CONNECTION: LOAD `� �� PV06 b. MAX INV OUTPUT CURRENT: 12A 11 l City of R01 c. PV AC DEDICATED OCP DEVICE RATING: 12A d. UTILITY AC DISCONNECT REQ'D: YES COMMUNITY DEVELOPMENT R02 STRUCTURAL APPROVED R03 a. MAX ALLOWABLE SPACING BETWEEN ATTACH R04 T&r Code Compliance b. MIN. NUMBER OF ATTACHMENT POINTS: 18 R05 c. WEIGHT PER ATTACHMENT POINT: 26LBS 1 R06 d. PV DEAD LOAD: 3.OPSF IA e. LENGTH OF RAIL REQUIRED: 64ft 0*1-s minerate R07 The issuance of a permtyor approval of plans speciijko wns ono c pf"puflsttons shah not be a permit JbrA or an approval of any Wolobon to any of the provlslons of the budding rode or of any City ordinances. Ptrrmns pmming to g4v authority to violate or cancel the provisions of the 9uilditsg codes or other ord--�nnces of the City shodf not be valid. Sheet Title COVER NOTES E_PV SITE PLAN LINE DIAGRAM S_PV SITE PLAN PV ATTACH PLAN MODULE DATASHEET INVISIMOUNT DATASHEET INVERTER DATASHEET OPTIMIZER DATASHEET INVISIMOUNT SPAN TABLE SUNMODO DATASHEET GROUNDING DATASHEET Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Proiect Tvoe - Photovoltaic Project Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC; 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING: INVISIMOUNT 4. ROOF TYPESHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23' File Name: 01_KOSSMAN_COVER. D WG Sheet Number and Title: PV01-COVER Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) 1 01 1 DCG 1 -- 13/6/18 1 Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com city of 4 Wheat Ridge O PV01 1 2 3 4 5 6 7 8 9 10 11 INSTALLATION NOTES ELECTRICAL NOTES STRUCTURAL NOTES Contractor Info 1. THE EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 1. INSTALLATION TO BE COMPLIANT WITH NFPA 1 & NFPA70 (NATIONAL 1. PV SYSTEM CONSIST OF THE PV MODULES, RAILING, AND PHOTON BROTHERS MANUFACTURES INSTALLATION INSTRUCTIONS. ELECTRICAL CODE) CONNECTION HARDWARE 7705 W 108th Ave A 2. THE ACTUAL LOCATION OF THE ARRAY AND PLACEMENT OF THE 2. THE INVERTER HAS INTEGRATED GROUND AND NO DC GEC IS 2. RACKING SYSTEM & PV ARRAY SHALL BE INSTALLED ACCORDING Westminster, CO 80021 MECHANICAL ANCHORS ARE SUBJECT TO VARIANCES DEPENDING ON REQUIRED. THE DC CIRCUIT IS ISOLATED AND INSULATED FROM TO CODE -COMPLIANT INSTALLATION MANUAL SITE CONDITIONS AND/OR ROOF OBSTRUCTIONS. THE CONTRACTOR GROUND AND MEETS THE REQUIREMENTS OF 690.35 (UNGROUNDED 3. THE ATTACHMENTS SHOULD BE STAGGERED, WHERE POSSIBLE, SHALL VERIFY ALL DIMENSIONS AND SPECIFICATIONS BEFORE PHOTOVOLTAIC POWER SYSTEMS) TO ALLOW DISTRIBUTION OF THE DESIGN LOADS EVENLY TO THE COMMENCING. 3. THE EXACT LOCATION OF NEW ELECTRICAL EQUIPMENT AND CONDUIT STRUCTURE. 3. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM RUN RELATING TO THIS PROJECT IS SUBJECT TO CHANGE AND WILL 4. ALL ROOF PENETRATIONS SHALL BE FLASHED AND SEALED BY NEMA3-R RATING. BE DETERMINED ON SITE BY THE CONTRACTOR APPROVED METHOD PER ROOF TYPE MANUFACTURE Project Type - Photovoltaic 4. ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4. THE PV SYSTEM IS EQUIPPED WITH A RAPID SHUTDOWN SYSTEM AND 5. TYP. ROOF SUPPORT STRUCTURE; 2" X 4", 24"O.C. 5. ALL WORK SHALL COMPLY WITH THE BUILDING CODES SET FORTH BY SATISFIES THE REQUIREMENTS OF THE NEC SEC. 690.12 6. REFER TO TABLE 1.1 FOR MAX OVERHANG FROM LAST Project Location: THE GOVERNING JURISDICTION. 5. ALL EQUIPMENT TO BE LISTED OR LABELED FOR ITS APPLICATION(UL ATTACHMENT. 6. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY THE OR OTHER APPROVED LISTINGS) 7. PV ARRAY SHALL BE A MINIMUM 3" ABOVE THE ROOFING KOSSMAN RESIDENCE NATIONAL FIRE CODE, NFC AND THE NATIONAL ELECTRICAL CODE, NEC. 5.1. PV MODULE - UL1703 MATERIAL. 2835 Ames St, 5.2. INVERTER - UL1741 GENERAL PV SITE NOTES 5.3. RACKING SYSTEM - UL2703 LOAD INFORMATION Wheat Ridge, CO 80214 1. PV ARRAY NOT TO DISRUPT ATTIC VENTS OR PLUMBING VENTS. ARRAY 6. GROUNDING 1. THE COMBINED LOADS WITH THE PV ROOF EQUIPMENT INSTALLED (309)825-6536 TO SPAN OR EXTEND TERMINATION PLUMBING VENTS WITHOUT ANY 6.1. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE ARE NOT LARGER THAN THE COMBINED LOADS AS REQUIRED BY Nickkossman@gmail.com IMPACT ON THEIR FUNCTIONALITY. REQUIREMENTS OF NEC ARTICLES 250 & 690 THE BUILDING CODE FOR THE ROOF WITHOUT PANELS. 2. PANELS WILL NOT EXCEED THE OVERALL HEIGHT OR ROOF PITCH OF 6.2. MODULE BONDING METHOD SHALL BE INTEGRATED GROUNDING 2. NUMBER OF ATTACHMENT POINTS: 18 Parcel Number: 39-254-16-007 THE EXISTING STRUCTURE. MID CLAPS. REFER TO MANUFACTURES SPECIFIC INSTRUCTIONS 3. WEIGHT PER ATTACHMENT POINT: 26LBS Assessor Phone # (303) 271-8260 FOR PROPER BONDING TECHNIQUES. 4. PV DEAD LOAD: 3.OPSF ABBREVIATIONS 6.3. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR 5. DESIGN SNOW LOAD (E) - EXISTING PURPOSE, AND GROUNDING DEVICES SHALL BE RATED FOR 5.1. GROUND SNOW LOAD - 30PSF PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC; 2.68 (N) -NEW DIRECT BURIAL 6. ALLOWABLE DESIGN LOADS FOR PV MODULE: C TYP - TYPICAL 6.4. EGC SHALL BE SIZED IN ACCORDACE WITH 250.122 AND ARRAY 6.1. WIND = 62PSF kWdc 2. INVERTER:SOLAREDGE SE3000H-US NTS - NOT TO SCALE EGC'S SMALLER THAN 6AWG SHALL COMPLY WITH 250.120(C) 6.2. SNOW= 125PSF 3. RACKING: INVISIMOUNT MIN - MINIMUM 7. ALL CONDUCTORS ARE COPPER, UNLESS SPECIFIED OTHERWISE 4. ROOF TYPE:SHINGLE MAX - MAXIMUM 8. ALL CONDUIT, RACEWAYS, AND JUNCTION BOXES SHALL BE SIZED 5. H:90,1 80 ROOF SLOPE: 23' 6. ROOF 23" AC -ALTERNATING CURRENT ACCORDING TO THE APPLICABLE CODE IF THE SIZE IS NOT SPECIFIED. DC - DIRECT CURRENT 9. SIGNAGE SHALL BE APPLIED ACCORDING TO GOVERNING BUILDING PV - PHOTOVOLTAIC CODES AND LOCAL JURISDICTIONS SPECIFIC REQUIREMENTS. File Name: MOD - PV MODULE 10. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR 02_KOSSMAN_NOTES.DWG INV - DC/AC PV INVERTER EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC. POC - POINT OF CONNECTION(PV) 11. CALCULATION OF MAXIMUM CIRCUIT CURRENT FOR THE SPECIFIC RSB - RAPID SHUTDOWN BOX CIRCUIT SHALL BE CALCULATED IN ACCORDANCE WITH 690.8(A)(1) Sheet Number and Title: D CB - CIRCUIT BREAKER (EX. 20A/2P CB - 20AMP 2 -POLE CIRCUIT BREAKER) THROUGH (A)(5). CONDUCTOR AMPACITY SHALL BE SIZED TO NOT PV02 - NOTES C - CONDUIT CARRY LESS THAN THE LARGER OF 690.(B)(1) OR (2) Sheet Size: OCP - OVERCURRENT PROTECTION 12. DC PV SOURCE AND DC OUTPUT CURRENT CIRCUITS ON OR INSIDE A OCPD- OVERCURRENT PROTECTION DEVICE BUILDING SHALL BE CONTAINED IN METAL RACEWAYS, TYPE MC ANSI full bleed B (17.00 x 11.00 Inches) MSD - MAIN SERVICE DISCONNECT METAL -CLAD CABLE THAT COMPLIES WITH 250.118(l 0), OR METAL DISC - DISCONNECT ENCLOSURES FROM THE POINT OF PENETRATION OF THE SURFACE Drawing history MSP - MAIN SERVICE PANEL OF THE BUILDING OR STRUCTURE TO THE FIRST READILY ACCESSIBLE no. drawn by revision date SP - SUB PANEL DISCONNECTING MEANS.(690.31(G)) 01 DCG - 3/6/16 PLP - PROTECTED LOADS PANEL 13. ACCESS TO BOXES; JUNCTION, PULL, AND OUTLET BOXES LOCATED MLO - MAIN LUG ONLY BEHIND MODULES OR PANELS SHALL BE SO INSTALLED THAT THE MB - MAIN BREAKER WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE Design E EGC - EQUIPMENT GROUNDING CONDUCTOR DIRECTLY OR BY DISPLACEMENT OF A MODULE(S) SECURED BY GEC - GROUNDING ELECTRODE CODUCTOR REMOVABLE FASTENERS AND CONNECTED BY FLEXIBLE WIRING Godwin Engineering and Design, LLC GES - GROUNDING ELECTRODE SYSTEM SYSTEM.(690.34) 8378 Foxtail Loop Pensacola, FL 32526 14. PV POINT OF CONNECTION. THE OUTPUT OF AN INTERCONNECTED D. Chad Godwin, PE ELECTRIC POWER SOURCE SHALL BE CONNECTED AS SPECIFIED IN Chad@godwineng.com 705.12(A),(B),(C), OR (D). SYMBOLS UTILITY METER F PV MODULE DC/AC UTILITY INTERACTIVE INVERTER GAY of �- DISCONNECT _- CB DOUBLE POLE - - CB SINGLE POLE Wheat Ridge -- FUSE �- FUSED DISCONNECT� Nps G 1 Ing DOW FPV02 NEC LABEL NOTES: 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC 110.21(B) A 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. B WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LABEL 1 - NEC 690.13(B) LOAD SIDES MAY BE ENERGIZED IN APPLY TO DISCONNECTS THE OPEN POSITION DISCONNECT UTILITY PHOTOVOLTAIC:]_ UTILITY REQUIRED LABEL APPLY TO PV AC DISCONNECT UTILITY REQUIRED LABEL APPLY TO UTILITY METER LABEL 5 - NEC 705.12(6)(3) PHOTOVOLTAIC SYSTEM CONNECTED LABEL 2 - NEC 690.31(G)(4) APPLY TO EXPOSED RACEWAYS, CABLE TRAYS, WARNING: PHOTOVOLTAIC OTHER WIRING METHODS, COVERS, POWER Si ENCLOSURES OF PULL BOXES, AND J -BOXES. SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE MORE THAN 1OFT APART. CPHOTOVOLTAIC TURN RAPID SYSTEM DC DISCONNECT LABEL 5 - NEC 705.12(6)(3) SOURCES: UTILITY GRID AND PV APPLY TO MSP SOLAR ELECTRIC SYSTEM LABEL 3 - 690.53 WARNING: MAX SYSTEM VOLTAGE: 480VDC APPLY TO DC CONNECTION: DO NOT RELOCATE APPLY TO BACK -FED BREAKER, MAX CIRCUIT CURRENT: 20A DISCONNECT/INVERTER ARRAY. PHOTOVOLTAIC SYSTEM AC DISCONNECT LABEL 4 - NEC 690.54 RATED AC OUTPUT CURRENT: 12A APPLY TO MAIN PV AC NOMINAL OPERATING VOLTAGE: 240VAC DISCONNECT IC E F G WARNING: TURN RAPID DUAL POWER SUPPLY LABEL 5 - NEC 705.12(6)(3) SOURCES: UTILITY GRID AND PV APPLY TO MSP SOLAR ELECTRIC SYSTEM SHUT DOWN PV WARNING: POWER SOURCE OUTPUT LABEL 6 - NEC 705.12(B)(2)(3)(b) CONNECTION: DO NOT RELOCATE APPLY TO BACK -FED BREAKER, THIS OVERCURRENT DEVICE IF APPLICABLE SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SNATCH T THE "OFF" POSITION T SHUT DOWN PV SYSTEM AND REDUCE ft SHOCK HAZARD IN THE ARRAY. LABEL 7 - NEC 690.56(C)(1)(a) APPLY TO LABEL ON OR NO MORE THAN 3FT FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED PV ARRAY WITH SAFETY DISCONNECTS AS SHOWN: PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN Ox UTILITY METER/MAIN COMBO E 150A, 150A M ❑ PV PRODUCTION METER(N UTILITY REQ'D PV AC DISCONNECT(N) 60A, NON-FUSED PV DC/AC INVERTER(N) W/ INTEGRATED DC DIS AND EQUIPPED WITH RAPID SHUTDOWN LABEL 10 - NEC 705.10 DIRECTORY OR PLAQUE APPLY TO LOCATION APPROVED BY AHJ. DIRECTORY OR PLAQUE PROVIDING LOCATION OF MSD AND PV DISCONNECT PV MODULE PV SITE PLAN W/ MODULE LAYOUT �DjScale: 3/32" = 1'-0" 701 MAX 17 MODULES PER STRING STRING 1 = 9 N Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Proiect Tvoe - Photovoltaic Project Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@gmaii.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC. 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23` File Name: 03_2017NEC_E_PV SITE LAYOUT.DWG Sheet Number and Title: PV03 - E_PV SITE PLAN Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com city 0'. Wheat Ridge PV03 E F 1 1 9 1 11 1 A R I A 1 7 1 0 1 n I oln 1 nn Project Derails PV Module Data SolarEdge Inverter alta rojeet Name KOSSMAN Projeft location WHEAT RIDGE, CO Module - 9 SlmPower SPR.E19.320-DC lwcrter I SolyEdge SE3=i US Ltllity- 240 Vac DC Rating 2.88 kW AC Rating 2.4 kW Ron -Ambi ent Temp. 'C -24 .11.2'F Max. Ambient Temp, "C 36 96.8 T Model Number SPR -E19.320 -DC Nominal Output Q STC Pmp 320 Mock Open Circuit Voltage, Voc 64.8 WE Max Power Point. Vmp 54.7 Vdc 5hortGrcult Current, Isc 6.24 A Max. Power Point Curr". imp 5.86 A VOCTemp CoeN -0.27 %r•C Dimensions, LxWxH(m) 61 -4x41 -18x1.81 weigill 41 1 lbs Model Number Max DC PcwLr(STC) DC W -x Voltage DC Max input Current AL Max Output Power Vomi nal Output Voltage (Vac) AC Max Output Current CEC Weighted Efficiency Dimensions. LxWxH (in) Weight SE3000H-US OPtimiter Data Dptinrze* CICinput Power coax inW Voftege VPPT Range Max DCinput Curren Max Output Current Max Output Voltage Min. aof Opt-s/String Max tl of Opt'5/5tring Max Watts/5trin P400 400 Wdc 80 Vdc 880 Vdc 12.5 A 15 A 60 Vdc 8 15 5700 PV Source Circuit Calculations Rofstrings 1 InyerterA String 4 1 Max #of Mod les/Strong Modules per string 9 Maximum System power (W) 1Vatts/Suing 2880 Voltage Correctirnn Factor, Low -OperatingCurrent 7.6 Voltage Correction rector, High flaf strings Solarlidge Fixed String Voltage String 4 1 2 ,Maximum System Voltage Modules per string Source G rcu.t Current Watts/Suing Max Source Circuit Current O ratio Current 17 Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 �- 4650 Wdc Vdc A Wac Vac A % 480 2.880 8.5 1.1323 3000 0.9703 240 380 12.5 480 94 Is 17.7x14Ax6-8 14 25.3 lbs XCEL PV PRODUCTION METER NOTES: THERE IS ANY REASON THIS CANNOT BE ACCOMPLISHED, THE APPROVAL OF THE PROPOSED PV PRODUCTION 1. THE SELF-CONTAINED METERING WILL BE IN COMPLIANCE WITH THE CURRENT REVISION OF THE XCEL ENERGY METERING WILL NEED TO BE OBTAINED BY THE LOCAL ELECTRIC METER SHOP. Project Type -Photovoltaic STANDARD; SPECIFICALLY SECTION 4.11, OR AS MAY BE AMENDED 5. A 200A SELF-CONTAINED LEVER BYPASS METER SOCKET TO BE PROVIDED FOR XCEL PV PRODUCTION METER. 2. THE PV PRODUCTION METER WILL BE REQUIRED TO HAVE THE PV GENERATION WIRED TO THE LINE SIDE 6. A PLACARD AT THE UTILITY NET METER WILL DESCRIBE THE LOCATION OF THE AC DISCONNECT AND THE TERMINALS (TOP OF METER BLOCK) PRODUCTION METER IF THEY ARE NOT GROUPED TOGETHER. 3. THE METER SOCKET FOR THE PV PRODUCTION METER SHALL BE MARKED WITH A STAMPED BRASS, ALUMINUM, 7. 20OA/240VAC UTILITY METER TO BE LABELED WITH PLACARD "PHOTOVOLTAIC SYSTEM CONNECTED" OR STAINLESS STEEL TAG, INDICATING THE ADDRESS INCLUDING THE UNIT, TYPICALLY" PV PROD" IN 8. THE AC DISCONNECT SHALL BE ACCESSIBLE, LOCKABLE, VISIBLE FROM NET METER, AND LABELED WITH Project Location: KOSSMAN RESIDENCE 2835 Ames St, ACCODANCE WITH THE REQUIREMENTS FOR " METER IDENTIFICATION" IN SECTION 4.14.4 OF THE XCEL ENERGY PLACARD "UTILITY PHOTOVOLTAIC DISCONNECT" STANDARD, OR AS MAY BE AMENDED. 4. THE PV PRODUCTION METER SHALL BE LOCATED WITHIN TEN (10) FEET OF THE EXISTING UTILITY METER. IF Wheat Ridge, CO 80214 (309)8256536 Nickkossman5-6536 .com Parcel Number: 39-254-16-007 UTILITY REQ'D PV AC DISCONNECT(N) Assessor Phone # (303) 271-8260 60A, NON-FUSED,240Vac GENERAL DUTY, NEMA 3R, SERVICE UTILITY METER E MANUAL, LOCKABLE, LOAD -BREAK 200A, 120/240Vacj1 ,3W PV INVERTER N DISCONNECT SWITCH SOLAREDGE SE3000H-US PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -1118 -320 -DC; 2.88 kWdc 12A MAX AC OUTPUT PHOTOVOLTAIC SYSTEM 2. INVERTER: SOLAREDGE SE3000H-US W/ INTEGRATED DC DISCONNECT UTILITY PHOTOVOLTAIC CONNECTED AND EQUIPPED WITH DISCONNECT 3. RACKING: INVISIMOUNT 4. ROOF 5. AZIMUTH g0,S810NGLE RAPID SHUTDOWN C METER/MAIN COMBO SERVICE PANEL E 6. ROOF SLOPE:23° 150A, 150A MB, 120/240Vac Q PV -ADD 20/2 C. B. PV MODULE N i ■� I0 PV POINT OF CONNECTION (POC) ui LOAD SIDE CONNECTION A LU .x - DEDICATED OVERCURRENT DEVICE m F11e Name: 04_KOSSMAN_LINE DIAGRAM.DWG Sheet Number and Title: PV04 - LINE DIAGRAM to _ 705.12(B)(2)(3)(B) Sheet Size: 150A*120% = 180A _ �= PV 12A' 1.25 = 15A, 20A C.B. ANSI full bleed B (17.00 x 11.00 Inches) _� �= 150A(MB) + 15A(PV) = 165A <= 180A OK Drawing history_ no. drawn by revision date 01 DCG SOLAREDGE OPTIMIZER N GROUNDING ELECTRODE (E) P400 GEC Design B 1 1 Godwin Engineering and Design, LLC ------------- ---- -- ----------------' 8378 Foxtail Loop Pensacola, FL 32526 PV PRODUCTION METER SOCKET J -BOX N C 200A, 1 20/240VAC,MIN. NEMA 3R "CUSTOMER GENERATION PRODUCTION D. Chad Godwin, PE Chad@godwineng.com METER / OPEN AC DISCONNECT BEFORE REMOVING METER" Conduit and Conductor Schedule Conductor Siting 1 city of Wheat t ea Ridge Tag Min. Conductor Description and Conductor Type Gauge Number of Conductors Typical Conduit Type Min. Conduit Size Max one way length (ft) PV Source Ckt Inverter put Ckt I D stance above•oof 2;2,•:3 V2 n. IMASex PVDisto•nnect(AC) I AmbTe•no.AdderfurRuoftuas 'F) 4o Des'ignternperature('F) 44 I Design.temperature(°F) 136.8 MaxAmb:eottern -Kane t s< -9S 310.1610■21l•: I A Mods to box j- PV Wire 10AWG + (,-) FREEAIR MFG CABLE 20 Adustpr.' 1pmp. Ra .fn•RaM 137-140 31"520.612h.1 Tema. Ratio of C-nnducro• 751C 1 Temp,Ral'nofCo•nductor 901C No. of CurrentCarryirCond. <4 amcsWA.lwl B j -box to Inv., PV Wire 10AWG (+,-,) (G) EMT or FMC 1/2" 40 No. of Cu real La•r in Cord. 4-6 nc IABOXO AC Max Output Current 12.5 E90.d.x::3' �C oy" 5` g DNIN Max Source CIrtL't Current Is 690.aupsi ACMax Output Current a 125% 15.6 caoarR1 I C Inv to POC, THWN-2 6AWG Ll, L2, N, (G) PVC, EMT, or FMC 3 4" / 10 Max Sm,ce C:rcult Cur-ert'125% 18.8 690 BiBali Overcurrert Protection (Al 20 Amb• TemaCor•ecConFactor 071 imntsk2k.r Amb. Temp Correction Factor 0.94 1 liai5ax2o; RacewaVFill Adjustment Factor 8096 as° 1%90:0Raceway Fill Adjustment Factor 100%ago 15iekax41 1 Notes: NEC 690.45-46, W're Gauge(AWGI 10 7101519x161 Wire Gauge (AWG) 6 101itB;;:6; I A loveable Ampacit (Amps 40 Allowaole Ampacity (Amps) 6S I (G) can be #8AWG THWN-2 Table 250.66, Table 250.122 Ac'usted Arn%Idl Ams 23 Adjusted Am acit A 1 Al " For Conduit sizing refer to Chapter 9 Tables, NEC PV04 G C E F 1 1 I A I r. I A 7 1 Q I a I in 1 1.1 Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 • PANEL • , SOLAR >• • SOLAR PANEL MAXIMUM EFFICIENCY D PERFORMANCE MAXIMUM EFFICIENCY AND PERFORMANCE Project Type - Photovoltaic BENEFITS E Highest Efficiency Electrical Data I-V Curve 1 hMhw�ia SC td 4+-''Cr.+b,...,�4ttG �iOIA..4 i�, u,+iiaM „Y w"e+vn«+n?5 7 PeakPower (+5/3%I Pmax 320 W I 6 7177 FM1`m ct5 E(Bciency ri 19.6 % 100•W/up l 5 - --a Project Location: KOSSMAN RESIDENCE 35 Ames St, Wheat Ridge, CO 80214 (309)825-6536 SunPower"' Solar Panels are the most SERIES efficient photovoltaic panels on the market today. _ ew Rated Voltage Vmpp 54.7 V q w/"'' Rated Current I 5.86 A 3 mpaw1, y Open Circuit Volrcgey°C 64.8 V� I Nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 More Power Our panels produce more power in r the some amount of space—up to 50% more than conventional designs and g o 100% more than thin film solar panels. Short Circuit Current Ix 6.24A t saow/t. 0 -- - Maximum System Voltage UL 600 V - -- 0 10 20 30 40 50 60 70 Temperature Coefficients Power IPJ .0.38%/ K Val" M vol v6.6mv/K " - t� N«1 eco on na&ama and module tem Cwrenr/whoga <hm«imp>nca wdh derrmi nets we PV SYSTEM SPECIFICATIONS 1 PV MODULE: 9 x SPR -E18 -320 -DC, 2.88 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING: INVISIMOUNT Reduced Installation Cost Current(ty) 3.5mA/K — -- - — Tested Operating Conditions NOCT 45° C +/-2° C 4. ROOFTYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23° power per P More panel means fewer Panels per install. This saves both time - and money. The planet's most powerful solar panel. Reliable and Robust Design Proven materials, tempered front gloss, The SunPower" 320 Solar Panel provides today's highest efficiency and a sturdy anodized frame allow and performance. Utilizing96 back -contact solar cells, the SunPower panel to operate reliably in multiple � mountin confi urations- 320 delivers a total panel conversion efficiency of 19.6°x. The 320 g g panel's reduced voltage temperature coefficient, anti -reflective gloss and — Temperature 40° F to +185° F (40° C to + 85° C) Series Fuse Rating 20 A Max load w kg/ (5400 Pal,(e.g. snow) Mechanical Data w specified mounting c 245 Pa) front and back-e.g. Solar Cells 96 SunPower all -back contact monoc stalhne - — ry — wind _ . High transmission tempered glass with Front Glass Impact Resistance Hail 1 in 25 mm at 23 m s anti -reflective (AR) coating P I 1 Phi m/sl Junction Box IP -65 rated with 3 bypass diodes j Dimensions: 32 x 155 x 128 (mm) Warranties and Certifications Output Cables 1000mm length cables /MultComact (MC4J connectors Warranties 25 year limited power warranty i Anodized aluminum alloy type 6063 Frame (black) 10 year limited producrwarranty File Name: R01 MODULE-SPR320.DWG Sheet Number and Title: R01 - MODULE DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Drawing history exceptional low -light performance attributes provide outstanding energy deliver per peak ower watt. Y P P P Weight 41.0 lbs (18.6 kg) Certifications Tested to UL 1703. Class C Fire Rating no. drawn by I revision I date Dimensions 01 DCG — — SunPowet's tftgh EffidencyAdvantage26'r. ° 18% 19/0 20% a ,,� .....• 1S% 1A% r�. o 10% 10% - 5% —.. 2X 12CO 2X [ar.2n' [10-3Z) - 12 b6.a _ ex I MM 2y. 30 [.261 [7.071 2X 577 9 6d.2 4X 23C.E (IN) [1.183 --- [22.7{.1, �_ '. [.171 f9.L*?] F [1.Z 1 X C,+2 6X IX2 [47.-81 f3?.451 Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE ,►,, ° - �- -- --� -- - ---- 11, 0 /o Thin Film Conventional SunPower SunPower E 18 Series E 19 Series i — - ,( � 4x 322 2X 915 _�,.5 -61.39) 1.5159 II•.- I72a9] [36.021 [10.30] -" 4'— --��"• �' i 46 AX 12 2:: 1535 [1.81 [.97] [6C.4S1 SPR -320E WHTD cOus Viso do?aik SLINFOAD 0°nd�.suN�i,°°. ad�„d���gio—d„°d-.i.atS.W. mar°. sunpoweP p.com �sy D.—b.20105uNkmer Gvporon°n. N AghY -,.d. spedt7,x;o,o IncludM4 ed in drmMer ere ebday,e wrMwr n.11-n.11-Duc3­­fJDI 65474474 v” /LIR- EN R01 0 IQ C solar -•. c. Single Phase Inverters for North America SE3000H-US 1 SE380OH-US / SE500OH-US / SE6000H-US / SE760OH-US / SE1000011-US F 9 0 solarM7,7 ,,40 r; Optimized installation with HD -Wave technology - Specifically designed to work with power optimizers - Record-breaking efficiency - - Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 - UL1741 SA certified, fol CPUC Rule 21 grid compliance - Extremely small - High reliability without any electrolytic capacitors - Built-in module -level monitoring mmoHD - Outdoor and indoor installation wave - Optional: Revenue grade data, ANSI C12,20 Class 0.5 (0.5% accuracy) www.5ol:11edgems solar• e Single Phase Inverters for North America SE300OH-US I SE380OH-US / SE5000H-US I SE6000H-USI SE760OH-US I SE100001-1-US SE30001-1-u5 SE38001-1-US SESOOOH-US SE600OH-US SE760OH-US SE100DOH-US OUTPUT `ar•rfe, Rated AC PawerOutput I 3000 3800 5000 6000 7600 10000 VA O 3000 4) 5000 6000 7600 10000 VA AC Output Voltage Min: Nom I........ vac 2¢4}.... ....... - .................:.... ........I ........ ....,... ,...,.,.......,..,. ,..... ........ .... - .. ..,............ D AC Frequency (Nominal) a Hz Maximum Continuous Output 12.5 16 Ir.. 21 25 _ 32 42 A _ Current�240V .. ..... ................... .... .,..., I .._ ..........I _.... ...L ...... , .......1...... _... GFDI Thfvhold F 9 0 solarM7,7 ,,40 r; Optimized installation with HD -Wave technology - Specifically designed to work with power optimizers - Record-breaking efficiency - - Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 - UL1741 SA certified, fol CPUC Rule 21 grid compliance - Extremely small - High reliability without any electrolytic capacitors - Built-in module -level monitoring mmoHD - Outdoor and indoor installation wave - Optional: Revenue grade data, ANSI C12,20 Class 0.5 (0.5% accuracy) www.5ol:11edgems solar• e Single Phase Inverters for North America SE300OH-US I SE380OH-US / SE5000H-US I SE6000H-USI SE760OH-US I SE100001-1-US INPUT t 9300 I...,..1180D ..,..�,.,...155oo-.,.....,. W.,... Transformer less, Urst rounded........ Yes ..................................................... ............... ..........-._......... _..........................._...-..... Maximum InputYoltage 480 Vdc Nominal DC Input Yalt380 400 Vdc age Maximum Input Current�240V.... ....8:? ........10:5.......!...... 13:? ....... .......1�:?.,- _. ,.,.... 24...,....,�........ 27............Adc... Max.h putShortgrcultCurrent45 Adc Ground Fault Isolation Detection 600kasensihvrty - -Maximum Inverter Efficiency, 99 �. 492- .......... .......................................... .......... CECWeighjFdEfyciencY ............. _...,,... ..... _.._.._...... `%_... .................................... Nighttime Power Co'n'sumption < 2.5 W ADDITIONAL FEATURES supported Communication lntcrfa 85485, Ethernet, ZigBee (optional), Cellular (optional) _......?F................................................................................................................................................... Revenue Grade Data, ANSI C12.20 Optionah'1 Rapid Shutdown - NEC 2014 and t .... is Ra ,....., .., d Disconnect ...:.............. .........�.......... 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B CSA C22 2 Canadian A acmrdmgto TI L M 13 .. .. - -.. .-- --- . ----- Grad Connection Standards IEEE_1547 Rule 21 Rule 14 (HI) ........ . Emissions FCC Part 15 Class B _INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG - - - -- - _ - - - - - Rana31,V minimum 120-4 AWG DC Input Conduit Sire / k of Strings 3/4 minlmum / AWG Range 3/4' minimum/ 1-2 strings / 14-6 AWG / 1-3 strings / ...,... .... ........................ ..................................._............. ...__.......... ..... .14¢AWG.,. ,.. ._.. Dimensions with Safety Switch 21.3 x 14.6 x (HxWxD) 17.7x14.6x6.8 /450x370x174 7.3/540x370 in/mm ..... ............................ I..............,............, ................ ......................x.185....... ........... Weight w th Safety Switch 22 / 10, 25.1 11.4 2b.2 11.9 38.6 17.6 Ib ....................... ........i........./...................,.._...../.........,...................�........, ....�.... Nols,e.....................:.................................................� 25........,....,............. ...I.. GP41)P$..........................._.. Natur�lConvection....................... NaturaJwnvectlon ProtectlonRating ......................................_.....,.........,,.tYEMA3R(Inverterwith5afetySwitch)..,.....,.. 111 For Mbar ragloml setdryfs please mnta:t SolarEdge support a Ravenna grade Inwerrar PIN: sr—H-LWauNNQ For power dei lrg Information refer to: httpsl/www.sciamcip..oWsite5/ddautUfilWw-temperature-detar,4m- ate+ a.pdf a,-00 version P/N: SEx H-USo00NNU4 1 Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Project Type - Photovoltaic Proiect Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC, 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23` File Name: R02_I N VERTER_SE-H. DWG Sheet Number and Title: R02 -INVERTER DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com R02 SE30001-1-u5 SE38001-1-US SESOOOH-US SE600OH-US SE760OH-US SE100DOH-US OUTPUT Rated AC PawerOutput I 3000 3800 5000 6000 7600 10000 VA Max. AC Power Output 3000 3800 5000 6000 7600 10000 VA AC Output Voltage Min: Nom I........ vac 2¢4}.... ....... - .................:.... ........I ........ ....,... ,...,.,.......,..,. ,..... ........ .... - .. ..,............ AC Frequency (Nominal) 59.3 : 60 - 60.5111 Hz Maximum Continuous Output 12.5 16 Ir.. 21 25 _ 32 42 A _ Current�240V .. ..... ................... .... .,..., I .._ ..........I _.... ...L ...... , .......1...... _... GFDI Thfvhold 1 A ... ... ._ d, ._ ..... UtilityMonitaring,lslanding _... ..------ .__.... _.......,...-................ .......... .. Protection; Country Configurable Yes Thresholds INPUT t 9300 I...,..1180D ..,..�,.,...155oo-.,.....,. W.,... Transformer less, Urst rounded........ Yes ..................................................... ............... ..........-._......... _..........................._...-..... Maximum InputYoltage 480 Vdc Nominal DC Input Yalt380 400 Vdc age Maximum Input Current�240V.... ....8:? ........10:5.......!...... 13:? ....... .......1�:?.,- _. ,.,.... 24...,....,�........ 27............Adc... Max.h putShortgrcultCurrent45 Adc Ground Fault Isolation Detection 600kasensihvrty - -Maximum Inverter Efficiency, 99 �. 492- .......... .......................................... .......... CECWeighjFdEfyciencY ............. _...,,... ..... _.._.._...... `%_... .................................... Nighttime Power Co'n'sumption < 2.5 W ADDITIONAL FEATURES supported Communication lntcrfa 85485, Ethernet, ZigBee (optional), Cellular (optional) _......?F................................................................................................................................................... Revenue Grade Data, ANSI C12.20 Optionah'1 Rapid Shutdown - NEC 2014 and t .... is Ra ,....., .., d Disconnect ...:.............. .........�.......... 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B CSA C22 2 Canadian A acmrdmgto TI L M 13 .. .. - -.. .-- --- . ----- Grad Connection Standards IEEE_1547 Rule 21 Rule 14 (HI) ........ . Emissions FCC Part 15 Class B _INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG - - - -- - _ - - - - - Rana31,V minimum 120-4 AWG DC Input Conduit Sire / k of Strings 3/4 minlmum / AWG Range 3/4' minimum/ 1-2 strings / 14-6 AWG / 1-3 strings / ...,... .... ........................ ..................................._............. ...__.......... ..... .14¢AWG.,. ,.. ._.. Dimensions with Safety Switch 21.3 x 14.6 x (HxWxD) 17.7x14.6x6.8 /450x370x174 7.3/540x370 in/mm ..... ............................ I..............,............, ................ ......................x.185....... ........... Weight w th Safety Switch 22 / 10, 25.1 11.4 2b.2 11.9 38.6 17.6 Ib ....................... ........i........./...................,.._...../.........,...................�........, ....�.... Nols,e.....................:.................................................� 25........,....,............. ...I.. GP41)P$..........................._.. Natur�lConvection....................... NaturaJwnvectlon ProtectlonRating ......................................_.....,.........,,.tYEMA3R(Inverterwith5afetySwitch)..,.....,.. 111 For Mbar ragloml setdryfs please mnta:t SolarEdge support a Ravenna grade Inwerrar PIN: sr—H-LWauNNQ For power dei lrg Information refer to: httpsl/www.sciamcip..oWsite5/ddautUfilWw-temperature-detar,4m- ate+ a.pdf a,-00 version P/N: SEx H-USo00NNU4 1 Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Project Type - Photovoltaic Proiect Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC, 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23` File Name: R02_I N VERTER_SE-H. DWG Sheet Number and Title: R02 -INVERTER DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com R02 ICA C C E F C A I R I F 1 7 1 A I a 1 1n I II Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 solar=@@ so I a r ' • • SolarEdge Power Optimizer Module Add -On for North America Project Type -Photovoltaic Project Location., P320 / P370 / P400 / P405 / P505 Q Q m p SolarEdge Power Optimizer Module Add -On For North America P320 P370 P400 P405 OPTIMIZER MODEL(for higher -power (for high-power (for 72 8 96 -cell iforthin film (typical module compatibility) 60 and 72 -cell � 60 -cell modules) modules) modules) modules) INPUT Rated Input DC Powerpl 320. 370 400 405 P505 (for higher current moduees) 1 SDS W KOSRESIDENCE 2835 Ames St, 2835 Wheat Ride, CO 80214 9 (309)825-6536 nickkossman@gmail.com P320 P370 / P400 / P405 P5t}5 — ....... ..... ................................................. Absolute Maximum Input Voltage at lowest tem erasure 49 60 so f 125 (!...............P........)........................................................................................................................................... MPPTOperati!.R?^lre.................... .I.....8.:�................8.:60............... 8.:x.............x:5.:105.........,...12.?. Maximum Short ClrcuR Current (Isc) 11 10.1 l 83 ...... 14 vdc ,..,V ..... Adc Parcel Number: 39-254-16-007 Assessor Phone # 303 271-8260 ( ) Maximum DC In ut Current 13.75 12.63 .... .......... P.................................................................... I..... 17.5 I..,................. Adc .. Maximum Effiderxy ........................ 995 .................... ............................... Weighted Efflclen 98.8 .....................�.............................,................................,......................................................................................... Overvoltage, Cate gory 98,6 .......... % % PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 xSPR-E18-320-DC: 2.88 kWdc OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED_ TO OPERATING SOLAREDGE INVERTER) MaxlmumOutputCurrerrt _ 15 ......................................................................................I........................................................... Maximum Output Voltage 60 i 85 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) _ Adc Vdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23° Safety Output pu Voltage per Power Optimizer 1 f 0.1 Vdc tem e YfgKB • STANDARD COMPLIANCE -- - - — -- �-- ------ -- - EMC FCC Part15 Class B IEC61000.6-2 IEC61000.6-3 ................. ................................................................t..........,..,:..,..,...................................................... R?�?S............................................................................IEC62109 1(daI s??e?Y)UL1741.................... ..................... Name: r�R02AOPTIMIZER DATASHEET.DWG yes Sheet Number and Title: ' INSTALLATION SPECIFICATIONS _ Maximum Allowed System Voltage........ ,.......1°00................................................... .................................................,.............................. Compatible inverters All SolarEdse Si idle Phase and Three Phase inverters Vdc .............. R03 -OPTIMIZER DATASHEET 128x152x36% 128x152x50J Dimensions (W x L x H) 128x152x28/5x597x11 Sx597x142 Sx597xL „................................ 96 128x152x59J 1 Sx597x2.32 mm/In Sheet Wei M Include cables 630 1.4 750 17 "JAVA ......... � ........... �.....,,...1.........../ 1064 2.3 .............g.i....... r Ib ANSI full bleed B (17.00 x 11.00 Inches) Input Connector MCRui OutputWlre /Connector _............................................. Double lnsulated:MC4.._ Out utWireLe th 095/30 1.2)3.9 ......................................................................................................... OperatingTemperutureRanBe . m/ft �l..F... Drawing history no. drawn by revision date 01 DCG -- — ................. ...................: ..................... Protecdan Rating .................................... ........ IP66 / NEMA6P Relative Humidity 0 -100 Iv Rated STC power of the module. Module of up m+516 power tolerance allowed. Design m for wherwnnectortirm please emend solartdge PV SYSTEM DESIGN USING SINGLE PHASE A SOLAREDGE INVERTERN01 HO -WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE a80V Godwin Engineering and Design, LLC 8378 Foxtail Loop Minimum String Length P320, P370r P40° . ...................... B 10 18 Pensacola, FL 32526 .................. „(PowerOytimi¢ers) 6 8. 14 D. Chad Godwin, PE PV power optimization at the module -level ..................... Maximum String Length so (s) Chad@godwineng.com - Specifically designed to work with SolarEdge inverters 5700 (6000 with i Up to 25% more energy Maximum Power per String SE760oH-US, 5250 6°°0 ........................._................ SE10000HUS).... !_ -_....._...........I... 12750 W s Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerancetD partial shading • Flexible system design for maximum space utilization Fast installation with a single bolt .... - ......... ......... ...... Parallel strings of Different Lengths Yes w Orientations �w.araiea.n+res,:Ina ara �.no� madtp✓�r ww.n a Ie It 6 not rlk—d to mt. P405fP505 with P32WPMP40p/Pg00(P700/P8W Jne m sMu %.Ies/string-atrJng_na.�f. e A sMng with more than 30 opxmhera does not meet NEC rapid ahuobwn requirements; wfety voltage wIB b..I— the 30V requFemerrt ......... - Next generation maintenance with module -level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) - Module -level voltage shutdown for installer and firefighter safety UN j f . g , '�w+� s c r r�r ��i? �,�. Y �1 �t���?.. "r ��tr �2-, �,� ! www,solaredge.us R03 W C 101 E F G VA !t• �. �1•' Simple and Fast Installation Integrated frioricile-1 rail grounding Pre assembled rnld and end Ciarnps Module* 1 Mid Clamp and Rail Module* / End Clamp and Rail Levitating mid clamp for easy placement • wild clamp wCab facilitates Consistent, even module spacing _ Simple predrilled rail splice L1L 2703 Listed integrated grounding s Flexible Design Addresses nearly ali sloped residential roofs Design In landscape tired portrait Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap 4 = `s enable easy ob,;tac e management Customer -Preferred Aesthetics �fJ ... t 1 n, cLllr a id # 1 rri;Ut,ttng tit thetics *W" ' Best m �,Ias: 5ysteni ap' ,l he Ur, Elegant Simplicity Premium lcaw pi ofile desi€r, Bloc I• dn'aclUe] Cnmporle0t5 SunPower* InvisiMountTMl is a SunPower-designed PAa erial Black oxide stainless steel AISI 304 Hldrit i _ rr;ir, t t: mr+s �nc1 inti r lamf?s rail -based mounting system. The InvisiMount system End Clamp and idU(jed fli.;Sh rails 110 g (3.88 oz) addresses residential sloped roofs and combines faster Black anodized alurrinum alloy 6005-T6 Part of Superior System installation time, design flexibility, and superior aesthetics. Rail Splice Built for Iicp with ;tmpower X and Al mOdules a30 g/m (9 ozJft) The InvisiMount product was specifically envisioned and 304 stainless (A2-70 bolt tinplated copper lug) ' R -c St Ili class systion, rellbbihry and aesthetics End Cap Cominne veolt Sunpowet mt�rdules and engineered to pair with SunPower modules. The resulting 10.4 g (037 oz) Component Mid Clamp PAa erial Black oxide stainless steel AISI 304 Weight 63 g (2.2 oz) End Clamp Black anodized aljrrincm alloy 6063-T6 110 g (3.88 oz) Rail Black anodized alurrinum alloy 6005-T6 830 g/m (9 ortW Rail Splice Mum num alloy 6D05 -T5 a30 g/m (9 ozJft) Ground Lug Assembly 304 stainless (A2-70 bolt tinplated copper lug) 106.5 g/m (3.75 oz} End Cap Black acetal (POM) copolymer 10.4 g (037 oz) Temperature -40° C to 90° C (-40° F to 194' F) Max Load (LRFD) ' 3000 Pa uplift • 6,300 Pa dowrliorce 25 -year product warranty Warranties 5 -year finish warranty 7. mo"aotlr,g, ,i(1p tem -level approach will amplify the aesthetic and UL 2703 Listed � PP P fY Certifications Class A Fire Rated installation benefits for both homeowners and installers. Cornposition Shingle Rafter Attachment Composition Shingle Roof Decking Attachment Application Curved and Hat Tile RoofAttachment Universal Interface for Other Roof Attachments Refer to roofattachment hardware manufacturers documentation. T' sunpower.com *iviodole.'ranre tat is cornpatbe v& the IrvisiF.Aoun sys;eri required for lurdmre interoperabilie/ (02015 SunPuveer Cc:pwadan,A:I k1ov3 Reserved SUNPOWER, the SUNPOWERlogo,and INVISIMOUNT ure tredern. ksormastered tmdernarw of SunPower Co, orati^n. All other tmden•.arl�are the propertyoftheirrespecthe owners, sunpower.com Specifications included in this dasasieetare svb)ett to charge w0vut notice. Document #509506 RevC Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Proiect Twe - Photovoltaic Project Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320-13C, 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING: INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23` File Name: R03 INVISIMOUNT DATASHEET.DWG Sheet Number and Title: R04 - INVISIMOUNT DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) 1 01 1 DCG I — I— I Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE R04 0 193 SU -N P C�`, E !R Invisimount Span Tables Part 1: Simplified Tables (Wind Tunnel Loads) How to Use These Tables Determine whether the site meets all of the conditions listed below. ❑C E F G If any boxes are checked No, use the General (ASCE 7-10 Analytical Method) tables, found in Part 2 of this document. Determine the snow load for your site, and select the corresponding table. Determine the wind speed and roof slope for your site. The value in the table, for this wind speed and roof slope, is the allowable span between attachment points, in feet. SUNRiOWER INVISIMOUNT ALLOWABLE SPANS (FT) Yes No 22.62 ° 26.57 ° 30.26 ° 0 ❑ Mean roof height is 30 feet or less Gable end width (or smaller dimension if no gable) is 40 feet or less 4:12 e❑ x 6:12 ❑ Ridge length (or longer dimension) is 60 feet or less Exposure C Q ❑ Roof slope is 4:12 to 8:12 6 6 6 ❑ Wind speed per ASCE 7-10 is 140mph or less x❑ ❑ Snow load is 50 psf or less C Snow (psf) Q 115 Seismic acceleration Ss is15 3g (note, this covers most of the United States) 6 6 Q 6 Site is not located in Exposure D (i.e. within 600 feet of a coastline in non - 30 120 6 6 hurricane areas) 6 6 El Site is not located on a ridge or hilltop x❑ All PV modules are set back at least 10 inches from ridges and roof edges ❑C E F G If any boxes are checked No, use the General (ASCE 7-10 Analytical Method) tables, found in Part 2 of this document. Determine the snow load for your site, and select the corresponding table. Determine the wind speed and roof slope for your site. The value in the table, for this wind speed and roof slope, is the allowable span between attachment points, in feet. SUNRiOWER INVISIMOUNT ALLOWABLE SPANS (FT) slope 4 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° Inputs Speedy 4:12 5:12 6:12 7:12 8:12 Exposure C 110 6 6 6 6 6 Ground >15, Snow (psf) 5530 115 6 6 6 6 6 Height (ft) 30 120 6 6 6 6 6 Seismic, Ss (g) 2.999 125 6 6 6 6 6 130 6 6 6 6 6 135 6 6 6 6 6 140 6 6 6 6 6 Notes Tables are based on strength of the Invisimount rail and L -foot/ lag screw roof attachment hardware, in conformance IBC 2012, IBC 2015, and referenced standards. Wind speeds are ultimate values in mph, as defined in ASCE 7-10. Wind pressure coefficients are derived from wind tunnel testing in conformance with ASCE 7-10 Chapter 31. Tables are valid for mean roof height <_ 30 ft, gable end width 5 40 ft, and ridge length <_ 60 ft. Tables are valid for open country or suburban terrain (Exposures B or C). Tables apply to any location on the roof, except that PV modules must be set back at least 10 inches from all ridges and roof edges. These tables are valid for use with the Invisimount L -foot and lag screw attachment to rafters. They are not valid for other attachment devices. Allowable cantilever at the end of the rail is 2 ft - User is responsible for verifying the strength of the roof. Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Project Type - Photovoltaic Proiect Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC, 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23' File Name: R03 INVISIMOUNT SPAN TABLE.DWG Sheet Number and Title: R05 - INVISIMOUNT SPAN TABLE Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE R05 0 M M FBI E F G S UNMO�a T Lag reference withdrawal (pull' out) design caper - (lbs.) in typical lumber: Douglas Fir, Larch ific Gravity •50 per 1" thread depth 266 �' Shaft per 2-1/2" thread depth 665 Douglas Fir, South •46 235 588 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 2.35 588 Hem, Fir -43 212 530 Hem, Fir (North) .46 235 588 Southern Pine •55 307 768 Spruce, Pine, Fir .42 205 513 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 266 1 665 Sources: American Wood Council, NDS zoos, Table 11.2 A, 11.3.2 A Notes: 1) Actual test data in Southern Pine: Test Load at 0.250 inch deflection:1,800 lbs. uplift (withdrawal); 240 lbs. lateral. Test Load at 0.125 inch deflection: 695 lbs. uplift (withdrawal); 130 lbs. lateral. See Uniform Evaluation Service Report 0248 for allowable load values and conditions. 2) Thread must be embedded in a rafter or other structural roof member. 3) See NDS Table 11.5.1 C for required spacing requirements, edge and end distances. See NDS Table 10.3.1 for all applicable adjustment factors. The PSF Corporation, a Nationally Recognized Laboratory, has tested our 4 screw mounting using four #15 screws into 1/2" 3 ply CDX plywood deck. The average maximum withdrawal resistance, pull out, value reported is 1147 IV. Screw manufacturers such as Simpson, OMG and most others have pull out values listed for their product. Consult your structural engineer to select the appropriate fasteners for your application. L -Foot Hex Cap 5116 X 4 5' Lag Bolt Roof shoe Flashing IN Cross section of EZ Roof mount attachment for composite roofs. Self -tapping screw, deck mounting, shown on the left. 4.5" lag bolt, rafter mounting, shown on the right. SunModo Corp 11905 E 5'h Street, Suite A I Vancouver, WA 986611360-844-0046 Document Number D10041-VO02102016 — SunModo Corp. 5 Versatile aluminum base for multiple configurations. Raised flashing designed to divert water flow. Various standoffs available for easy adjustment. r Leak -proof engineering and design with sealing point protected from elements. Versatile mounting options including direct -to -decking for easy and quick installation. Durable aluminum anodized finish provides exceptional resistance to corrosion and wear. Performed flawlessly in major storm conditions. IAPM0 certified for waterproofing and structural integrity ;i1!) 9 9* -1 _�JiJ r �;r.j !J:__) �' I'�'� a=J�J All kits come complete with the following parts: 64A i 1- Al Shoe Part# A20065 -M . 1- EZ L Foot Pan# A20064-001 1 -Flashing I 1- Hex Cap �? Part# A20052-001 Pan# A20066001�•- It- Q U 1- Lag Bolt SS 5/16 x 4.5 Part# 615015-004 4 1. 1- Bolt 3/8 -16 x 3/4" 1- Flange Nut 3/8 - Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Proiect TvDe - Photovoltaic Project Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC; 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE:23° File Name: R04 SUNMODO DATASHEET.DWG Sheet Number and Title: R06-SUNMODO DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE R06 LAI I r' L LJ E F G The system features: • Integrated module -to -rail as well as adjacent -module bonding (achieved through the mid clamp and end clamp). • Integrated rail -to -rail bonding (achieved through the self -drilling splice screws and the splice). • System bonding is achieved through the ground lug assembly to the equipment ground conductor (EGC). Note. The ground lug is only required when installing DC modules for arrays that feature AC Modules this system bonding is achieved solely through the systems components. The following two diagrams illustrate the key grounding and bonding aspects of the InvisiMount system—for AC and for DC module scenarios: • the system ground path • each component • each bonding point • the applicable NEC and UL references Document #508988 RevF 16 SunPower Proprietary SU4 llkVIISIM tit � Gro I _ _l�� �. w •4Wak-4( ur"All k�rGa�c� Document #508988 RevF thrDC Mo -d( J `tElt 1. - - f_ O Nfr i 'r - *06"'04"1 ; e 0 !}!�:- w •4Wak-4( ur"All k�rGa�c� Document #508988 RevF thrDC Mo -d( J 18 SunPower Proprietary Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Proiect TVDe - Photovoltaic Project Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC, 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE 23* File Name: R05 GROUNDING DATASHEET.DWG Sheet Number and Title: R07 - GROUNDING DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Drawing history no. I drawn by I revision 1 date 01 1 DCG — — Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE R07 `tElt O Nfr i 'r - *06"'04"1 !}!�:- t 04! *tsli Iri(�41e frbl►iai i��j' � � �� b ! t� "l ow �i # fi>rla�rFrr r�aas +3i F�4q 1 En (impFa 00.01 3103 1 - WA60 18 SunPower Proprietary Contractor Info PHOTON BROTHERS 7705 W 108th Ave Westminster, CO 80021 Proiect TVDe - Photovoltaic Project Location: KOSSMAN RESIDENCE 2835 Ames St, Wheat Ridge, CO 80214 (309)825-6536 Nickkossman@@gmail.com Parcel Number: 39-254-16-007 Assessor Phone # (303) 271-8260 PV SYSTEM SPECIFICATIONS 1. PV MODULE: 9 x SPR -E18 -320 -DC, 2.88 kWdc 2. INVERTER: SOLAREDGE SE3000H-US 3. RACKING:INVISIMOUNT 4. ROOF TYPE:SHINGLE 5. AZIMUTH:90,180 6. ROOF SLOPE 23* File Name: R05 GROUNDING DATASHEET.DWG Sheet Number and Title: R07 - GROUNDING DATASHEET Sheet Size: ANSI full bleed B (17.00 x 11.00 Inches) Drawing history no. I drawn by I revision 1 date 01 1 DCG — — Design Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE R07 CITY OF WHEAT RIDGE '' Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: RQic—, Job Address: Permit Number: ZI GJ 3 ❑ No one available for inspection: Time f ( ALY/PM Re -Inspection required: Yes N� *When corrections have been made, call for re -inspection at 303-234-5933 Date: %� d 1 �� Inspector: / ! ,4 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Mtb Job Address: 3936 me :5+ - Permit Permit Number: 20/Wo*lI ❑ No one available for inspection: Time A Re -Inspection required: Yes No.,/ � When corrections have been made, call for ..4ry re -inspection at 303-234-5933 Date: (�J/a Inspector: DO NOT NOT REMOVE THIS NOTICE A City of Wheat Ridge ® Residential Roofing PERMIT - 201702193 PERMIT NO: 201702193 ISSUED: 06/20/2017 JOB ADDRESS: 2835 Ames ST EXPIRES: 06/20/2018 JOB DESCRIPTION: Residential Reroof: Install GAF Timberline HD 30year Asphalt Shingle 16 squares. *** CONTACTS *** OWNER (303)238-3662 GRAVES DANIEL SUB (303)548-5000 Alan Parkes 021001 Roof Corp of Metro Denver Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 6,875.00 FEES Total Valuation 0.00 -------__._, Use Tax 144.38 Permit Fee 156.75 ** TOTAL ** 301.13 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2-inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€ms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201702193 PERMIT NO: 201702193 ISSUED: 06/20/2017 JOB ADDRESS: 2835 Ames ST EXPIRES: 06/20/2018 JOB DESCRIPTION: Residential Reroof: Install GAF Timberline HD 30year Asphalt Shingle 16 squares. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of theproperty and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed -and that all worts to he }performed is disclosed i is document and/or its' accompanying approved plans and specifications. y' y Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based`on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 4 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Antoinette Kulick From: no-reply@ci.wheatridge.co.us Sent: Monday, June 12, 2017 10:14 AM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 3-5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address Do you have a signed contract to reroof this property? It will need to be provided at the time of permit pick-up. 2835 Ames St Dan & Alexandra Schlereth 720-270-1839 Field not completed. Yes CONTRACTOR INFORMATION Contractor Name Roof Corp. Contractor's License 021001 Number (for the City of Wheat Ridge) Contractor Phone 303-766-2444 Number Contractor Email Address permits@roofcorpinc.com (permit pick-up instructions will be sent to this email) Retype Contractor Email permits@roofcorpinc.com Address DESCRIPTION OF WORK Is this application for a Yes new permit for a residential roof? Are you re -decking the No roof? Description of Roofing Material Select Type of Material: If "Other" is selected above, describe here: How many squares of the material selected above? Does any portion of the property include a flat roof? If yes, how many squares on the flat roof? GAF Timberline HD, 30YR Asphalt Shingle Asphalt Field not completed. 16 No Field not completed. TOTAL SQUARES of all 16 roofing material for this project 2 Provide additional detail Complete tear off / reroof - 9SQ 4:12 pitch, 7 SQ - 9:12 pitch here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract 6875 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant Victor Aguilar Email not displaying correctly? View it in your browser. 3 1685 South Colorado Blvd, Ste 240 (303) 766-2444 office Denver, CO 80222 (303) 766-0077 fax roofcorp@msn.com email 6890 South Tucson Way R90fOFCORP www.roofcoTpinc.com Centennial, CO 80112 Metro Denver Inc. AGREEMENT FOR ROOF INSTALLATION CUSTOMER NAME: �).4 r)- An -a ✓ro, 5ct' Jcre �� ADDRESS: 2—Ates 51 City% 114-A d Zip ! ° PHONE: 7Z -0-2Z- email Roofcorp of Metro Denver Inc. hereby proposes to furnish the following: Roofing Material: 64 Color: ,Em /- C Rating: Z; P�i, Existing Layers: >+ Layers to be torn off. % Structures: r., The following items are included for all Roofcorp installations: Clean job site thoroughly removing all trash and debris. All flashin6 shall be replaced or sealed as necessary including pipe jacks, step flashing, chimneys and skylights. All roof installations shall be in accordance with required manufacturer specifications. Upon request, customer shall be provided with written invoice which includes lien waiver and 5 year roof certification. In addition to the manufacturer warranty, a ❑ 2 !- �5 year transferable workmanship warranty is included for all installations. It is understood that any decking which requires replacement shall be installed for an additional charge of $50 per 8x4 sheet. In the event that there are "hidden layers" found during tear off, an additional charge of $25 per 100 sgft per llayer m y apply. ADDITIONAL COMMENTS / ADDITIONS: �:I �^ •h ~�j� Gt�rt/v✓!d' Ql��vr� TOTAL PROPOSED COST TO INSTALL ROO ING SYSTEM: Note: Above price includes all taxes and fees but does NOT include any options listed below. ,� �rr�n • _ �r a �jr rf Payment terms: Payment is due upon completion and shall be cash or check. In the event the city inspections are delayed, customer fierees to pay 90% of contract price (or first insurance check) within 10 days of completion and balance once inspection is closed out. If payment is made with credit card there shall be an additional charge of 1.5% added to balance paid. Options and upgrades: (When initialed by customer, all option prices shall be added to the total proposed cost listed above.) Shingle upgrade: $+ Initials Shingle upgrade: $+ Initials Misc. upgrade: $+ Initials 5" seamless aluminum gutters and 2x3 downspouts: $+ Initials -�= <2,- date .� .� 7—r'J-7 date t Roofco Metro Denver Inc. ` Owner By signi this agreement, it is understood that this shall become a legally binding contract. Payment for above work shall be due upon completion. In the event that payment is not received within 10 days after completion, any remaining balance shall be subject to a late fee of 1.5% per month from the day of completion. Customer shall also be responsible for the cost of collecting said debt and will be additionally liable for all court costs, collection agency and attomey/legal fees. Customer shall have the right to cancel this agreement in writing within 3 days of signing. INSPECTION RECORD Occupancy/Type ~INSPECTION LINE: (303) 234-5933 ' Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. r ~W IF, P.` INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR `INITIALS COMMENTS:. Footings/Caissons Stemwal( / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof/ French Drain Sewer Service Lines Water Service Lines - POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR Electrical (Underground) Plumbing (Underground) Heating (Underground) 'UU HUI CUUR tLUUR UNTIL ABOVE HAS CEEN SIGNED ROUGHS Sheathing' 'Lath / Wall tie Mid-Roof Electrical Service Rough Electric Rough Plumbing Gas Piping' Rough Mechanical -ABOVE INSPECTIONS TO BE SIGNED PRIOR TO. PROCEEDING Framing :Insulation Drywall Screw FINALS Electrical :Plumbing Mechanical Roof 3009 /~E dK Po w 9 in T Building Final Fire Department R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE: ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSPTUTEAUTHORIZATION OFA CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED PROTECT THIS CARD FROM THE WEATHER ;,T ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: aaw k=/= Job Address: .9513< Arad c7= Permit Number: r~/.3> .4PP120V612 ❑ No one available for inspection: Time ~?'dd AM/PM Re-Inspection required: Yes "When corrections have been made, call for re-inspection at 303-234-5933 Date: 4&b1_102 Inspector: 11 DO NOT REMOVE THIS NOTICE ♦ A i CITY OF WHEAT RIDGE 9 Building Inspection Division f( (303) 234-5933 Inspection line 303) 235-2855 Office • (303) 235-2857 Far INSPECTION NOTICE Inspection Type: ,st9,rF ic,R41 Job Address: 2X3.5 4A4. ES _4 7 Permit Number: 020/3,! 94~rEn 42r, e5 ~F r~/SS~~n1 f~'7 "CJrJ 4 -1F 7;P 06' ❑ No one available for inspection: Time S® AM/PM Re-Inspection required: es No > "When corrections have been made, call for re-inspection at 303-234-5933 Date: -641 /L Z inspector: /v DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE Building Inspection Division r (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: 0acV1,:71 Job Address:,,? P3-5 1600*5 S7` Permit Number: 0 5'49✓ / V mecr -f-M,) 7 5ASr%o -"PS&L.7rAg~ FRem ~51/s 3T "1,5~VKP A07- ❑ No one available for inspection: Time 7,'.30 AM/PM Re-Inspection required: No "When corrections have been made, call for re-inspection at 303-234-5933 Date: elv .-7 Inspector DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 090631 PERMIT NO: -.090631 -ISSUED: - 06/09/2009 JOB ADDRESS: 2835 AMES ST EXPIRES: 12/06/2009 DESCRIPTION: 1/0 reroof with'GAF/ELK 17.3 sqs ***CONTACTS owner 970/.988-1177 AmyTilson sub 303/804-0303 Tom Brown 07-0055 North West :Roofing PARCEL: INFO ZONE CODE: UA USE: UA SUBDIVISION: 0527:' 'BLOCK/LOT#: 0/''. FEE SUMMARY ESTIMATED PROJECT VALUATION; 8,804.45 FEES Permit Fee 217.50M Total Valuation .00 (>p13GC~~Use Tax 158.48 t TOTAL 375.98 Conditions: 6 nail installation & mid roof inspection required..' Board sheeting spaced more than a 1/4 of an inch anart rPrniirPS.nlvwood overlay on entire roof Ice and water sheild require Subject to field ins Ihereby certifythat thee ordinances, rules or regulz measurements shown, and all application and that I asst applicable Wheat Ridge Ordi AA tions. =k 'distances proposed b} s of the City of Wheat F ions made are accurate;' all responsibility for -c as, for work under this inside exterior walls. this permit application are accurate, and do not violate apr v U 1. This permit was issued in accordance with the provisions sel .'State of Colorado and to. the Zoning Regulations and. Building !ordinances of the City. 2. This permit shall expire 180 days from the issue date.Regw date. An extension may be granted at the discretion of the 3. If this permit expires, a new permit may be acquired for a changes have been or will be made: in the original plans: and exceeded one (1) year `If changes have been or of suspensi~ be. paid for anew permit. 4. No work of any. manner shall be done that will change the nal 5. Contractor shall notify J, the Building Inspector: twenty-four written approval on inspection card before proceeding with 6. The . issuance . of a permit or the approval of drawings andspi as: subject. to.. field inspection rth:. in yourapplication and is subject to the-laws. of des of Wheat Ridge, Colorado or any other applicable for. an extension must be received prior to expirati iding Official_ if one-half the amount normally required, provided n( oificatrons and any suspension or abandonment has nol r abandonment exceeds one (1) year, full fees shall Lflow of water causing. a drainage.: problem an approval of, y lation of the provisions of the building. codes or any other ordinance, law;:. rule or. regulation. All plan rev w fact to field inspections. Signature of.C ef' ildmg: Official date INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE: (303)235-2855 REQUESTS MUST BE MADE BY 3PM: ANY BUSINESS._ DAY FOR:. INSPECTION THE. FOLLOWING.. BUSINESS DAY. oFW"E?TR City of Wheat Ridge Building Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 o inspection Line: 303-234-5933 OCORAO Building Permit Application Property Address: 29335 A I y1eS Property Owner (please print): Mailing Address: (if different than property address) Address: Date: ~C( oC-y Plan Permit #:~'I ~(p/] Phone: 910 I6B k 11-1 State, Contractor: Ndg4+1 VVe-Sa' (2-Oofi q Contractor License Phone: -2 50 3 S04 6.30 Sub Contractors: Electrical City License Company: Plumbing City License Company Mechanical City License Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): re, ro61- Construction Value: s 960 L{ - 4S Description of"work: : -}--CLC dK- 6(as calculated per the Building Valuation Data sheet) re4 a(.e W i t L -je y a- t CJ Plan Review (due at time of submittal): $ Sq. Ft:/L.Ft added: Squares IT 3 BTUs Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. CIRLCE ONE:: ~(OWNER) (CONTRACTOR) o PERSONAL REPRESENTATIVE (OWNER) ~ONTRATOR) PRINT NAME: ;y rCtF.LI~e LY SIGNATURE: Date: