Dear Mr. Kelley:
Conformance Observation Report
Remedial Roof Repairs
Monday, April 12, 2021
Conformance Observation Report
Balsam Street Project
14250 Balsam Street
I Wheat Ridge, Colorado 80033
Compliance Observation
Roof Framing Repairs/Enhancements
dec21082020-01
As requested, we performed onsite observation of the remedial repairs and enhancements
to the roof including the installation of new roof support beams and rafter reinforcement, at
the address referenced above. Our observations were performed during a portion of the
installation process.
The scope of work performed consisted of observation of portions of the remedial work and
placement of various structural components, during installation. The purpose of my review
was to confirm the extent and location of the remedial work and to verify that the repairs
were installed in substantial compliance with the permit plans and generally accepted indus-
try standards, procedures and practices. The following items were reviewed subsequent to
installation:
• Installation of new attic beams and associated framing elements.
• Installation of new beam bracing.
• Installation of new roof rafter sister joists and associated framing.
• Installation of associated blocking.
It should be noted that the interior foundation support that was proposed to be added in the
crawispace was omitted due to the presence of an existing foundation and footing. This
existing footing was used to support the interior column support adjacent to the bathroom.
My observations were performed during the installation of portions of the above-mentioned
elements. Not all of the repairs were directly observed. In my opinion, these specific
portions of the remedial work appear to be installed in a consistent manner with that shown
on the permit plans, previously submitted. To the best of my professional knowledge, belief
and opinion, and based on limited observations, it appears that the remedial work currently
4250 Balsam Street Page 1
Conformance Observation Report
Remedial Roof Repairs
Monday, April 12, 2021
in place appears to, generally, meet the applicable Codes, industry standards and
regulations of agencies having jurisdiction.
DavisEngineering
This scope of work included observation of the installation of remedial roof repair and
enhancement, as outlined in our previously submitted repair documents. Our scope of work
did not encompass any other portions of the property or buildings not listed nor does it
include the mechanical, electrical, architectural, or other structural features of the property/
buildings or any conditions beyond those described herein. Our observations were limited
to the items outlined in the repair plans.
5082 East Hampden Avenue
Suite 145 No invasive testing or inspections were performed. No responsibility is taken for any
Denver, Colorado 80222 conditions, which were not readily verifiable.
(303) 229-1234
robdavis@davisengconsultants.com
www.davisengconsultants.com I appreciate the opportunity to be of service. If you need additional information or have any
questions, please feel free to contact me at (303) 229-1234.
Respectfully submitted,
REGI
°
33741 ° Of
VV ONgL y,,�\�✓-
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
Robert C. Davis III, P.E.
Principal
4250 Balsam Street Page 2
C1
r)avisEnginEEring
C ON S U LTA N TS
5082 East Hampden Avenue
Suite 145
Denver, Colorado 80222
(303) 229-1234
robdavis@davisengconsultants.com
www.davisengconsultants.com
472250 Balsam St
1202100325
Joel Kelley
4250 Balsam Street
Wheat Ridge, Colorado 80033
PROJECT TITLE
PROJECT ADDRESS
PROJECT DESCRIPTION
DEC PROJECT NUMBER
Dear Mr. Kelley:
Conformance Observation Report
Remedial Roof Repairs
Monday, April 12, 2021
Conformance Observation Report
Balsam Street Project
14250 Balsam Street
I Wheat Ridge, Colorado 80033
Compliance Observation
Roof Framing Repairs/Enhancements
dec21082020-01
As requested, we performed onsite observation of the remedial repairs and enhancements
to the roof including the installation of new roof support beams and rafter reinforcement, at
the address referenced above. Our observations were performed during a portion of the
installation process.
The scope of work performed consisted of observation of portions of the remedial work and
placement of various structural components, during installation. The purpose of my review
was to confirm the extent and location of the remedial work and to verify that the repairs
were installed in substantial compliance with the permit plans and generally accepted indus-
try standards, procedures and practices. The following items were reviewed subsequent to
installation:
• Installation of new attic beams and associated framing elements.
• Installation of new beam bracing.
• Installation of new roof rafter sister joists and associated framing.
• Installation of associated blocking.
My observations were performed during the installation of portions of the above-mentioned
elements. Not all of the repairs were directly observed. In my opinion, these specific
portions of the remedial work appear to be installed in a consistent manner with that shown
on the permit plans, previously submitted. To the best of my professional knowledge, belief
and opinion, and based on limited observations, it appears that the remedial work currently
in place appears to, generally, meet the applicable Codes, industry standards and
regulations of agencies having jurisdiction.
4250 Balsam Street Page 1
DavisEngineering
5082 East Hampden Avenue
Suite 145
Denver, Colorado 80222
(303) 229-1234
robdavis@davisengconsultants.com
www.davisengconsultants.com
Conformance Observation Report
Remedial Roof Repairs
Monday, April 12, 2021
This scope of work included observation of the installation of remedial roof repair and
enhancement, as outlined in our previously submitted repair documents. Our scope of work
did not encompass any other portions of the property or buildings not listed nor does it
include the mechanical, electrical, architectural, or other structural features of the property/
buildings or any conditions beyond those described herein. Our observations were limited
to the items outlined in the repair plans.
No invasive testing or inspections were performed. No responsibility is taken for any
conditions, which were not readily verifiable.
I appreciate the opportunity to be of service. If you need additional information or have any
questions, please feel free to contact me at (303) 229-1234.
Respectfully submitted,
REGI
°
337414'**'—°O
VV ONgL,,,�\�✓-
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
Robert C. Davis III, P.E.
Principal
4250 Balsam Street
Page 2
� ► � i City of Wheat Ridge
-.A Residential Miscellaneous PERMIT - 202100325
PERMIT NO: 202100325 ISSUED: 03/11/2021
JOB ADDRESS: 4250 Balsam St EXPIRES: 03/11/2022
JOB DESCRIPTION: Install concrete footer in crawl space, Install 3 ft Adj steel pipe column,
Install new 1-3/4 ft LVL in attic; Sister new 2x10 rafters to existing roof
rafters for structural repairs
*** CONTACTS ***
OWNER (303)517-8566 KELLEY FAMILY TRUST
GC (720)922-3169 JAMES BATEMAN 100194 VANGUARD CONSTRUCTION
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 23,500.00
FEES
Total Valuation 0.00
Plan Review Fee 277.03
Use Tax 493.50
Permit Fee 426.20
** TOTAL ** 11196.73
*** COMMENTS ***
*** CONDITIONS ***
Work shall comply with 2018 IRC & 2020 NEC. Smoke alarms shall comply with 2018 IRC Section
134. Interior alterations, repairs, fuel -fired appliance replacements, or additions, any of
which require a building permit, occurs or where one or more rooms lawfully used for
sleeping purposes shall have an operational carbon monoxide alarm installed within fifteen
feet of the entrance to each room lawfully used for sleeping purposes.
1* ► � i City of Wheat Ridge
-.A Residential Miscellaneous PERMIT - 202100325
PERMIT NO: 202100325 ISSUED: 03/11/2021
JOB ADDRESS: 4250 Balsam St EXPIRES: 03/11/2022
JOB DESCRIPTION: Install concrete footer in crawl space, Install 3 ft Adj steel pipe column,
Install new 1-3/4 ft LVL in attic; Sister new 2x10 rafters to existing roof
rafters for structural repairs
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
03/11/2021
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: Residential Interior Remodel
Date: Friday, February 19, 2021 11:57:26 AM
Residential Interior Remodel
This application is exclusively for Residential Interior Remodels and other scopes
of work which do not have a specific form already available.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN
ORDER FOR THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Property Address 4250 Balsam Street, Wheat Ridge, CO 80033
Property Owner Name Joel Kelley
Property Owner Phone 303-517-8566
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email joel@tlecc.net
Address
Attach City of Wheat Electron ic-Payment-Form.odf
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
APPLICANT INFORMATION
Applicant Name James Bateman
What is your role in the General Contractor
project?
Wheat Ridge 100194
Contractor's License
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contact Phone Number 303-898-5088
(enter WITH dashes,
eg 303-123-4567)
Contact Email Address jc@vanguardltd.us
for Plan Review
Comments
Retype Contractor
Email Address
jc@vanguardltd.us
DESCRIPTION OF WORK
Detailed Scope of
Install concrete footer in crawl space, Install 3' Adj steel pipe
Work - In the space
column, Install new 1-3/4' LVL's in attic, Sister new 2x10 rafters
below (not as an
to existing roof rafters for structural repairs.
attachment), Provide a
detailed description of
work including
mechanical, electrical,
plumbing work
occurring,
adding/removing walls,
etc
I, the applicant, I have entered a detailed scope of work.
understand my
application will be
rejected if I do not
include a Detailed
Scope of Work.
Location of Work Roof, crawl space
Square Footage Area 1848
of Work Being
Performed
Asbestos Report Asbestos report 4250 Balsam St. .pdf
Upload letter size Fleld not completed.
documents here
Construction Plans 4250 Balsam pdf
scanned on 11 "x17" or
larger
Project Value (contract
23,500 Valuation OK
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full
Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work
Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have
Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
Person Applying for
James Batman
Permit
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Email not displaying correctly? View it in your browser.
Wheat Ridge
k W heat
U „CD
'
ri
0
c
G�jQil7g D �3.
Wheat Ridge
k W heat
dim
ri
Introduction
/ryjn9 D�jv3
On 2-9-21, 1 performed a limited inspection at the address listed above. I inspected for possible ACM in
the customers master bedroom wall, living room/dining room wall, and the attic insulation. The purpose
of this inspection is to remodel. No other part of the house was inspected.
1. Regulations
The EPA and the Colorado Department of Public Health and Environment (CDPHE) require all building
materials with Asbestos Containing Materials (ACM) contain less than 1% asbestos via PLM analysis. OSHA
requirements are more stringent.
It is required by law all friable and non -friable ACM be removed prior to renovation activities that may
disturb verifiable and assumed ACM. Furthermore, all friable ACM must be removed prior to demolition.
Point counting is required for bulk samples where the asbestos content is less than 10%. Federal and
State agencies define ACM as those containing more than 1%. National Emission Standards for Hazardous
Air Pollutants (NESHAP) requires materials with ACM less than 10% be point counted or be "assumed"
ACM. If point counting is done, the result supersedes the non -point counted PLM result.
2. Sample Results -
Sample
Location
Friable
Material
ACM
Percent
Condition
Name
Type
Type
ACM
Pi
Master
Yes
Surfacing
ND
ND
Good
bedroom
P 2
Master
Yes
Surfacing
ND
ND
Good
bedroom
P 3
Master
Yes
Surfacing
ND
ND
Good
bedroom
Pi
Dining room
Yes
Surfacing
ND
ND
Good
P 2
Living room
Yes
Surfacing
ND
ND
Good
P 3
Dining room
Yes
Surfacing
ND
ND
Good
Insulation
Attic
Yes
Miscellaneous
ND
ND
Good
1
Insulation
Attic
Yes
Miscellaneous
ND
ND
Good
2
ND= Not Detected above the laboratory reporting Limits
Wheat Ridge
ok VJ heat
3. Discussion of Results
Per the laboratory results, the plaster walls in the master bedroom and living room/dining room are all
non detect for asbestos. The attic insulation is also non detect for asbestos.
Laboratory Reports
(See below)
Wheat Ridge
aewiim Environmental OA Manual
Ok W heat
m
0
opatn9 ��yc
Q,V)AGG aRoaervoirs Environmental OA Manualgtli
REll LAB Reservoirs Environmental, lnE.
IMP" -
February
February 10, 2021 Subcontractor Number:
Laboratory Report:
Project #/P.O. #:
Project Description:
Janet Wooten
New Finish Interiors
7911 Irving Street
Westminster CO 80030
Dear Janet,
RES 484918-1
Joel Kelley
4250 Balsam St Wheat Ridge
Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code
101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the
American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase
Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT
programs respectively.
Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request.
The analysis has been completed in general accordance with the appropriate methodology as stated in the
attached analysis table. The results have been submitted to your office.
RES 484918-1 is the job number assigned to this study. This report is considered highly confidential and the
sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with
personnel other than those of the client. The results described in this report only apply to the samples analyzed.
This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of
the U.S. Government. This report shall not be reproduced except in full, without written approval from
Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested.
If you have any questions about this report, please feel free to call 303-964-1986.
Sincerely,
by Ryen Shilling
Jeanne Spencer
President
3) 9601986 6801 Lugan St, Suite 100, Denver, 0060216 ..relab.mm
6) RESI ENV lift,11dunta.reilffi4om
f vJ hea
o t p;
V •I
Wheat Ridge Co = 09:r
0
il7g 4v5.
c
Reservoirs Enaimm
nantal, Inc. Effective October 9, 2020
Reservoirs Environmental QA Manual Q:\QAQMabRaaamns Eminunmantal QA Manual..pff
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
TABLE: PLM BULK ANALYSIS. PERCENTAGE COMPOSITION BY VOLUME
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
not. SmmHnc fdncei.d.
RES 484918-1
New Finish Interiors
Joel Kelley
4250 Balsam St Wheat Ridge
For. ... —, no on91
Method: EPA 600/R-931116 - Short Report, Bulk ND=None Detected
Turnaround: Priority TR=Trace, <1% Visual Estimate
Trem/Act=Tremol de/Actinolite
Date Samples Analyzed: February 10. 2021
Client
L
Asbestos Content
Non
Non -
Sample
A Sub
Asbestos
Fibrous
Number
Y Physical Part
Mineral Visual
Fibrous
Components
E Description
;Estimate
Components
R
P 1 master
A White compound w/ bluish -green paint 10
ND
0
100
B Off white/multi-colored granular plaster 25
ND
TR
100
C White plaster w/ off white/multi-colored paint 65
ND
0
100
P 2 master
A White compound w/ bluish -green paint 10
ND
0
100
B Off white/multi-colored granular plaster 30
ND
TR
100
C White plaster w/ off white/multi-colored paint 60
ND
0
100
P 3 master
A White compound w/ bluish -green paint 10
ND
0
100
B Off white/multi-colored granular plaster 20
ND
TR
100
C White plaster w/ off white/multi-colored paint 70
ND
0
100
P 1 dining
A White plaster w/ beige/multi-colored paint & a trace of off 100
ND
TR
100
white/multi-colored granular material
P 2 Iv
A White plaster w/ beige/multi-colored paint & a trace of off 100
N D
TR
100
white/multi-colored granular material
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1 %.
P: 303-966-1986 5801 Logan Street, Sufte 100, Denver, CO 80216 1-8 RESI-ENV
F: 30347)4275 vrvm.reilab.com
Page 1 d2
Nl hea
o t p;
V •I
Wheat Ridge Co = :dr CID
0
r✓;�dil7g 4r5.
c
Reservoirs Environmental, Inc. ENacbva Doi 9, 2020
Reservoirs Environmental OA Manual 0:\DACC1abAin enmirs Environmental CA Manual -i
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
nate Ramnles Received -
RES 484918-1
New Finish Interiors
Joel Kelley
4250 Balsam St Wheat Ridge
Fehruarvne 91
Method: EPA 600/R-931116 - Short Report, Bulk
ND=None Detected
Turnaround: Priority
Date Samples Analyzed: February 10, 2021
TR=Trace, <1% Visual Estimate
Trem/Act=Tmmol ke/Actinolite
Client
L
Asbestos Content
Non
Non -
Sample
A Sub
Asbestos
Fibrous
Number
Y Physical Part
Mineral Visual
Fibrous
Components
E Description
R
Estimate
Components
P 3 dining
A White plaster w/ beige/multi-colored paint & a trace of off 100
ND
TR
100
white/multi-colored granular material
insuation 1 attic
A Brown/multi-colored insulation 100
ND
85
15
insulation 2 attic
A Brown/multi-colored insulation 100
ND
85
15
TEM Analysis recommended for organically bound material (i.e. Floor tile) if PLM results are <1%.
RYan ShAIYp
Analyst / Data i
P: 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-e RESI-ENV
Wheat
o Q;
L
Wheat Ridge Co
Feser s Env menW,lnc
Fesemoil Env ronmentsOAManuel
0
c
tj��,/ng
Eftxhae Omber09.N1N1
O+AAOCyabNeservoirs ErndronawmalOAManuM.pM
RET Reservoirs Environmental, Inc. RES Job #: 484918
SUBMITTED BY
INVOICE TO
CONTACT INFORMATION
SERIES
Company'. New Finish Interiors
Company: New Finish Interiors
Contact: Janet Wooten
-1 PLM Priority
...................................................................
Address'. 7911 Irving StreetAddress.
.......................................................................................................................................
..........................................
]911 Irving Street
Phone (303) 91] 5089
-2 Chem Priority
................................................................................................................................................
......... ..............
Fax
.......
3.
! R €': !
o
Westminster, CO 80030
Wntminster, CO BW30
Call
CHEMISTRY LABORATORY HOURS: Weekda s: Sam- Spirit
Project Nomber and/or P.O. 8: Joel Kelley
..................................................................................................................................................................................................................................................
Final Data Deliverable Email Address:
Project DeamptioNLocation: 4250 Balsam St Wheat Ridge
janet@neWinishinteriors.com
a
ASBESTOS LABORATORY HOURS: Weekda 3:7am -7pm S Sat. Sam - 5pm
REQUESTED ANALYSIS
VALID MATRIX CODES
LAB NOTES
PLM /PCM/TEM DTL RUSH PRIORITY STANDARD
Air=A Bulk=B
idsiFar
! EO
: ; g i
!
3.
! R €': !
o
........Dust.=.0........ _ ...............
........ .............. _ ... ....
Paint = P Soo = S
......Surface= $U..... ......Swab=SW.....
CHEMISTRY LABORATORY HOURS: Weekda s: Sam- Spirit
Dust RUSH PRIORITY STANDARD
a
.....Tape_.T....................Wipe=W....
'PRIOR NOTICE flE011mEO FOR SAME DAY TAT
lS E:
Edg b
"""'
Metals RUSH PRIORITY STANDARD
i
Drinking Water=DW
15o'aj
o
:—
I=S;ic_!
_
'
............... ................. ... .. .............
.....Waste Water=WW....
O Snits' SAME DAY RUSH PRIORITY STANDARD
a i.Z �i
; a 41 _
3 ::
'c
o
g
[ 7 Pu `i
m a $ c e ;,
i of a j g 3:
s
a"
rMIpns 2approved wipe media only
"ASTM Ia
MICROBIOLOGY LABORATORY HOURS: Weekda s: Sam- Spain
Viable Analysis" PRIORITY STANDARD
"TAT DEPENDEWON SPEED OFMICROBIALGROWTH
$$
3'� a �
i i H
@ Z a 3 u o
fl
Medical Device Analysis RUSH STANDARD
ow
s
;g a`a Coe e■?
Mold Analysis RUSH PRIORITY STANDARD
i o1a A)
w3" if
m ` 4 i <
s
- :
s: a
S
ioN
Ga� i I
"'Turnaround times establish a laboratorypriority, subject to laboratory volume an are not
P Y I Y
guaranteed. Additional fees apply for afterhours, Weekends and holidays.'
s a
i w j `s i
"^ G
m Y Bi
�—
i$ i <� 5 mi
u ` q�q
®i b
@ ` iRt s N E
E 6 i 8
> l I S E
Laboratory Analysis
Special Instructions:
a :r o o`; �'
"
o' s�
;oisluuow`i
; Is
9
Instructions
Client Sample ID Number I ieff'ooamuwbeuria l
ASBESTOS CHEMISTRY MICROBIOLOGY
1 P 1 master
X
B
2 P 2 master
........e..............e......i......e...................s......e.........................
%' i
i e
i e e
.....w.......
i
..... .. ... ..
i B
..........................................
3 P 3 master
......................e......e......a..................e......a......................a.......s.......
X' f
i e
i e e
i
.. .. ... ..
i B
..........................................
4 P 1 dining
......................e......e......a........................a......................a.......s.......
X' f
i e
i e e
i
.. .. ... ..
° B
..........................................
5 P21v
......................e......e......a........................a......................a.......s.......
%' e
i e
i e e
i
.. .. ... ..
i B
..........................................
6 P 3 dining
% e e
i e
i e
..
.. .. .....B....
] Insulation 1 attic
......................a......e......a........................a......................i.......e.......
% e e
i e
e e e
e
......B
.. .. ... ..
..........................................
S Insulation 2 attic
........ E............a......e......a
% e e
........................a......................a.......a.........
i e
e e I
e
......B .. ... ..
..........................................
8 Bob
........ I ............ e......
e...... a ........................
%
e...................... s.......
e e e
a.........
e
.........y........ e......P.....a .. ... ..
..........................................
HEI wllworm, inwmnq nerses Mead onirearroon mill aria will not no respmsolemrmors or omiSSms in cacNamns,esver, imn the, infauracy of ongma aataeysigniW,cl*m mpanywmwntaaveagreesnvlsudmsnonVaresoll iWsanplesmrrpwe anayssninacasxonmrscnMn Ml:us mMlmnsm
ananWy Wsoml sMwmeM paynlent%misol NETMda s. FmlumtocanplywdhpaymeMtemsmayrdulllna1 SSmmthlyintereslsumfor,.
Relinquished By: `"�" -r °•` Janet Wooten Date/Time: 02/09/2021 16:17:37 Sample Condition: Acceptable
Received By: Sophia Ingram Date/Time: 02/09/2021 16:25:34 Carder: Hand
Wheat Ridge Co
k D-
., r
Off' c
1876
Colorado Department
t.
of
c Health
-'r d Environment
ASBESTOS
CERTIFICATION
r
This certifies that
r
Janet Wooten
Certification No.: 21813
has met the requirements of 25-7-507, C.R.S. and Air Quality Control
- ' Commission Regulation No. 8, Part B, and is hereby certified by the
state of Colorado in the following discipline:
Building Inspector*
i
Issued: March 1.0, 2020
Expires: March 28, 2021
This certificate is Valid only with the possession of a
current Ditision-approved training course certification
in the discipline specified above. Authorized APCs Repn sentative
SEAL a
4
4f
IV
- Paee 9 of 9
"'cling 0�%j '.
.o
►, � � 1876 .
t
Colorado Department
of Public Health
and Environment
ASBESTOS CON.SULTING FI _
Fhis cern fes at
i. New Finish Interiors
Registration No.: ACF - 22249
has met the registration requirements of 25-7-507. C.R.S. and the Air Quality Control
Commission Regulation No. 8, Part B. and is hereby authorized to perform asbestos consulting
activities as required under Regulation No 8, Part B. in the state of Colorado.
Issued: July 4?, 2020
` Expires: July 18, 2021
Au`.hori;W a.!•'C:; ?PDreeeritetive
v SEAL
...t'r ' ".h i'i'.� N. :. i.• +`i: i `; i' :`ii N'ift"-Z'i:`i:r; i.Y: '1 ..*.1 •ih-i )' •f� 'A' : i}•u" 't ': pi;•k'j: : u i:•A`. i. ,.i �.,••� ;..+t•'v„:
�GOOngDlyocSTRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT
4250 BALSAM STREET
WHEAT RIDGE, COLORADO 80033
I
114L. -at { zjdw-
- �t1M�L�wmL�Lj•uor,feL�l `—
APPROVED
Mike Theisen 03/07/2021
Plans Exam"" LMte
581e11fL47NLeii. JM ;w»YraleM�.a• �el'�K w.NtaA�x
rotioweribiwa.Arv.,.uL oe eprwiLlh4 •rt'�rwe/K e'�` t�f+Lonfip
°'1�4f iae P�'"�•'AI [Aa•Ati.�,i�n s('°!t �xoio.ri. wvsW
p^.^.'9'r..io.umsi!1.w wo1i14Ysovi eMawim d�.� �'W!'4
Lvft U�'u(M'�llxq}n (SIM 'AMe.a1i 1{rW'S><
PREPARED BY
DAMS ENGINEERING CONSULTANTS, LLC
5082 EAST HAMPDEN AVENUE
SUITE 145
DENVER, COLORADO 80222
(303) 2231234
CONTACT: ROBERT C. DAMS III, PE
15 -
Know whal5 b0(OW.
Call before youdig.
L]avosEn0lnee�InD
5082 E HAMPDEN AVE, SLATE 145
OCT 11, 2020
VICINITY MAP
FOR AND ON BEHALF OF DAMS ENGINEERING CONSULTANTS. LLC
COVERSHEET
DRAWING INDEX
SO.01
COVERSHEET
50.02
GENERAL NOTES
SO.04
GENERAL NOTES
SO.06
GENERAL NOTES
SO.07
GENERAL NOTES
SO.08
GENERAL NOTES
SO.09
GENERAL NOTES
SO.10
PLAN NOTES
51.00
FOUNDATION PLAN
51.01
CEILING FRAMING PLAN
S1.02
ROOF FRAMING PLAN
S2.00
DETAIL
S2.01
DETAIL
TITLE:
STRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT
4250 BALSAM STREET
WHEAT RIDGE, COLORADO 80033
PERMIT PLANS
SHEET NO:
S0.01
PROJECT NO. DK21082020-01 II SCALE: NONE I DATE: OCT 11, 2020
1. ALL. &STRUCTION SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE (IRC), 2018 EDITION AND APPLICABLE LOCAL CODES AND ORDINANCES.
di O.r
2? �ESIGN LOADS;
A. FLAT ROOF SNOW LOAD
30 PSF
GROUND SNOW LOAD
43 PSF
ROOF DEAD LOAD
15 PSF
B. FLOOR LIVE LOAD
40 PSF
FLOOR DEAD LOAD
10 PSF
C. ALLOWABLE BEARING PRESSURE
1,500 PSF
MAX END BEARING PRESSURE
25,000 PSF
MIN DEAD LOAD PRESSURE
15,000 PSF
EQUIVALENT FLUID PRESSURE (ACTIVE)
55 PCF
D. SOIL SITE CLASS
D
E. SEISMIC DESIGN CATEGORY
B
F. WIND PRESSURE
154 MPH (VuIU
OCCUPANCY CATEGORY
II
WIND EXPOSURE CATEGORY
C
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND LOCATE EXISTING UTILITIES AT THE JOB SITE BEFORE COMMENCING
CONSTRUCTION AND NOTIFY THE ENGINEER OF ALL DISCOVERIES HE BELIEVES MAY INTERFERE WITH PROPER EXECUTION OF THE WORK PRIOR TO
PROCEEDING WITH THE WORK.
4. THIS REPAIR DOCUMENT OUTLINES THE GENERAL CRITERIA FOR THE PARTIAL STRUCTURAL ENHANCEMENT TO A PORTION OF THE SUBJECT RESIDENCE AND
PROPERTY LOCATED AT THE INDICATED ADDRESS WHEN A DIFFERENCE OCCURS BETWEEN THIS SPECIFICATION AND OTHER APPLICABLE CODE, THE MORE
STRINGENT SHALL CONTROL. ANY OTHER ITEMS NOT COVERED HEREIN SHALL BE COMMENSURATE WITH GOOD ENGINEERING AND CONSTRUCTION
PRACTICE.
S. THE OWNER IS HEREBY CAUTIONED OF THE EXTREME IMPORTANCE OF PROPER DRAINAGE AWAY FROM THE FOUNDATION. THE OWNER IS RECOMMENDED TO
ESTABLISH AND MAINTAIN PROPER DRAINAGE FROM THE FOUNDATION, POOR DRAINAGE AND/OR PONDING OF WATER NEAR THE FOUNDATION WALL IS THE
SINGLE MOST COMMON CAUSE OF WATER INFILTRATION INTO BASEMENTS AND FOUNDATION DAMAGE.
6. WHERE DISCREPANCIES OCCUR BETWEEN PLAN, DETAILS, AND GENERAL NOTES, THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. DETAILS NOTED
TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR ELSEWHERE ON THE
PROJECT, CURRENT CODE REQUIREMENTS AND/OR STANDARD CONSTRUCTION PRACTICE.
7. ENGINEER'S APPROVAL SHALL BE SECURED FOR ALL SUBSTITUTIONS.
8. DRAWINGS SHALL NOT BE SCALED.
9. BOXED NOTED INDICATE TYPICAL NOTES.
10. THE CONTRACTOR STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE
CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEMBERS SHALL INCLUDE, BUT
NOT LIMITED TO, BRACING AND SHORING FOR CONSTRUCTION LOADS AND WORKER SAFETY REQUIREMENTS. OBSERVATION VISITS TO THE SITE BY THE
STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS.
11. THE RECOMMENDATIONS PROVIDED HEREIN ARE BASED ON OBSERVATION OF ELEMENTS VISIBLE AT THE TIME OF INSPECTION. IF ADDITIONAL DAMAGED
ELEMENTS ARE FOUND DURING RECONSTRUCTION, IT IS RECOMMENDED THAT THE ENGINEER BE CONT ,PT -INSPECTION OR THAT ALL
QUESTIONABLE ELEMENTS BE REPLACED. REG
naQ ..•e. �
12. IT IS RECOMMENDED THAT THE ENGINEER OF RECORD BE CONTACTED TO OBSERVE
CONNECTIONS ARE IN PLACE AND BEFORE FINISHES ARE APPLIED.
ELEMENTS AND
33741
OCT 1 1, 2020
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
GENERAL NOTES
TITLE: SHEET NO:
STRUCTURAL REPAIR AND MODIFICATION PLANS
oa�osrn9oiecdng BALSAM STREET PROJECT S O. 0 2
5082 E HAMPDEN AVE, SUITE 145 4250 BALSAM STREET
DENVER, CO 80222
(303) 229-1234 WHEAT RIDGE, COLORADO 80033
PROJECT NO. DEC21082020-01 SCALE: NONE DATE: OCT 11, 2020
AG; GENERAXISTING STRUCTURES
/of"17 `V'WINGS SHALL NOT BE SCALED.
2. THE LAYOUT IS APPROXIMATE AND IS INTENDED AS A REPRESENTATION ONLY.
3. THE REPAIR RECOMMENDATIONS CONTAINED IN THIS DOCUMENT ARE BASED ON INFORMATION OBTAINED FROM REVIEW AND EVALUATION OF
PROBLEMS THAT WERE MADE AVAILABLE FOR OUR REVIEW. NO CLADDING, SHEATHING, OR FINISH MATERIALS OF ANY KIND WERE REMOVED UNLESS
SPECIFICALLY NOTED. AS A RESULT OF THESE LIMITATIONS, LATENT STRUCTURAL DAMAGES MAY EXIST WHICH WERE NOT DETECTED. ANY SUCH
DAMAGES SHOULD BE BROUGHT TO OUR ATTENTION IF FOUND.
4. THE RECOMMENDATIONS CONTAINED HEREIN ARE BASED ON CURRENTLY EXISTING CONDITIONS AND HAVE BEEN PREPARED IN ACCORDANCE WITH
RECOMMENDED SOIL DESIGN CRITERIA AND GENERALLY ACCEPTED ENGINEERING PRACTICE. DUE TO THE LIMITATIONS NOTED ABOVE AND THE
CONSOLIDATING AND/OR EXPANSIVE SOILS KNOWN TO EXIST ON SITE, NO OTHER WARRANTY REGARDING THE FUTURE PERFORMANCE OF THE
STRUCTURE INCLUDING THE REMODELED AREAS ARE MADE, EXPRESSED OR IMPLIED.
5. NO WARRANTY REGARDING THE FUTURE PERFORMANCE OF THE REAPIRED AREAS IS MADE OR IMPLIED.
6. ADDITIONAL COSMETIC CRACKING CAN BE EXPECTED FOR A PERIOD OF ONE YEAR AFTER NEW WORK IS COMPLETED AS THE STRUCTURE ADJUSTS TO
THE NEW CONDITIONS.
FIELD DISCOVERY AND FIELD VERIFICATION
1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK AND SHALL NOTIFY ENGINEER AND CONDITIONS WHICH INTERFERE
WITH WORK.
2. WHEN A CONDITION IS NOTED AS "FIELD VERIFY" (FV) ON THE CONSTRUCTION DOCUMENTS THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD
VERIFICATION PRIOR TO PROCEEDING WITH THE WORK RELATED TO THAT CONDITION. FIELD VERIFICATION MUST BE COMPLETED IN A TIMELY MANNER
AND COMMUNICATED BY THE CONTRACTOR TO ALL AFFECTED PARTIES IN ORDER TO AVOID DELAYS TO THE WORK.
3. WHERE DIMENSIONS OR ELEVATIONS ARE INDICATED FOR EXISTING STRUCTURES, THEY ARE APPROXIMATE AND FOR REFERENCE ONLY. THE CONTRACTOR
SHALL FIELD VERIFY ALL RELEVANT EXISTING DIMENSIONS AND ELEVATIONS.
4. THESE DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS AND SITE OBSERVATION HAS PERMITTED BY ACCESS RESTRICTIONS DURING
DESIGN. DURING THE PROJECT, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS WHICH ARE NOT KNOWN OR ARE AT VARIANCE WITH PROJECT
DOCUMENTATION. CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER OF ALL CONDITIONS THAT DEVIATE FROM THESE DOCUMENTS. DEVIATION BY
THE CONTRACTOR FROM THE REQUIREMENTS OF THESE DOCUMENTS IS NOT PERMITTED WITHOUT PRIOR REVIEW AND APPROVAL BY THE OWNER AND
DAVIS ENGINEERING CONSULTANTS, LLC (DEC).
DavNGngln6All6 eing
5082 E HAMPDEN AVE, SUITE 145
DENVER, CO 80222
(303)229-1234
GENERAL NOTES
TITLE:
STRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT
4250 BALSAM STREET
WHEAT RIDGE, COLORADO 80033
oo^;ESTER o9GF
eh
j o 33741 _
,
OCT 11, 2020
FOR AM ON BEHALF OF DAMS ENGINEERING CONSULTANTS, LLC
PROJECT N0, DEC21082020-01 IISCALE: NONE
SHEET NO:
S0.04
DATE: OCT 11, 2020
t W heat
o -p;
r SHA STANDARDS
pC
G2/aN19 D14Z ELIMINAT NG HE NEED FOROTHE CONTT ACT RUNIT
COMPLY WITH ALLL OSHA REQU REMEMOSN HE STRUCTURAL DRAWINGS SHALL BE CONSTRUED
2. THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR BOLTS, PLATES, STIFFENER PLATES, STABILIZER PLATES, BRIDGING, BRACING, BEARING
SEATS, COLUMN SPLICES, ETC., AS WELL AS CLOSURES FOR OPENINGS. IN ADDITION, FIELD WELD ANYTHING THAT MAY BE CONSIDERED A TRIP HAZARD,
AFTER PROTECTIVE DECKING IS INSTALLED,
3. WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL DRAWINGS REPRESENT FINAL CONDITIONS
ONLY. THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING NECESSARY TO COMPLY WITH OSHA.
CONSTRUCTION ENGINEERING
1. THE STRUCTURE DEFINED ON THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY FOR LOADS ANTICIPATED ON THE STRUCTURE DURING ITS
SERVICE LIFE. PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO ACHIEVE THE MEANS, METHODS, AND SEQUENCES OF WORK. SUCH
ENGINEERING MAY INCLUDE, BUT IS NOT LIMITED TO:
-LAYOUT
- ERECTION PROCEDURES WHICH ADDRESS STABILITY OF THE FRAME DURING CONSTRUCTION
- WELD PROCEDURES
- DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND, SEISMIC, OR SOIL LOADS
- SURVEYING TO VERIFY CONSTRUCTION TOLERANCES
- EVALUATION OF TEMPORARY CONSTRUCTION LOADS ON STRUCTURE DUE TO EQUIPMENT AND MATERIALS
- STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS NOT IDENTIFIED ON DESIGN DRAWINGS
COORDINATION
1. ALL SUBSTITUTIONS MUST BE PREVIOUSLY APPROVED IN WRITING BY THE ENGINEER.
2. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL,
MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE
CONTRACT DOCUMENTS INTO SHOP DRAWINGS AND WORK.
3. COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS, DEPRESSIONS, ETC., WITH ARCHITECTURAL DRAWINGS, DRAWINGS FROM OTHER
DISCIPLINES, PROJECT SHOP DRAWINGS, AND FIELD CONDITIONS PRIOR TO SHOP DRAWING SUBMITTAL.
4. CONTRACTOR SHALL SUBMIT MATERIAL DATA SHEETS FOR CONSTRUCTION PRODUCTS AS NOTED IN DRAWINGS, AND FOR ANY PROPOSED
MATERIALS SUBSTITUTIONS FOR REVIEW BY ENGINEER. ENGINEER'S WRITTEN APPROVAL SHALL BE SECURED PRIOR TO PROCEEDING WITH THE
WORK.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL CONSTRUCTION ACTIVITY.
6. CONTRACTOR SHALL COORDINATE SITE STORAGE AND STAGING LOCATIONS IN ADVANCE WITH THE OWNER.
7. CONTRACTOR SHALL PROTECT PEDESTRIAN TRAFFIC AFFECTED BY CONSTRUCTION. CONSTRUCTION SHALL NOT BLOCK EGRESS/INGRESS
PATHWAYS, EXCEPT AS COORDINATED IN ADVANCE WITH THE OWNER.
8. THESE NOTES SUPPLEMENT THE DRAWINGS. WHERE A DISCREPANCY EXISTS BETWEEN THE GENERAL NOTES, PLANS AND DETAILS, THE MORE
STRINGENT REQUIREMENT SHALL GOVERN.
9. CONTRACTOR SHALL COORDINATE WORK SHOWN ON STRUCTURAL DRAWINGS WITH ALL OTHER DISCIPLINES. CONTRACTOR SHALL NOTIFY
ENGINEER OF ANY DISCOVERED CONFLICTS OR DISCREPANCIES BETWEEN STRUCTURAL DRAWINGS AND DRAWINGS FROM OTHER DISCIPLINES
PRIOR TO PROCEEDING WITH RELATED WORK.
10. CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND SEQUENCING OF WORK.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE SAFETY ISSUES AS MANDATED BY FEDERAL, STATE, AND LOCAL LAWS.
12. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE OSHA STANDARDS DURING EXECUTION OF THE PROJECT.
13. DO NOT SCALE DRAWINGS.
14, ITEMS NOTED AS "TYPICAL" APPLY TO ALL SIMILAR WORK ON THE PROJECT, UNLESS DETAILED OTHERWISE.
15. REFERENCES ON THE DRAWINGS TO "ENGINEER" MEAN THE STRUCTURAL ENGINEER OF RECORD.
16. FABRICATE AND ASSEMBLE IN SHR TO GREATEST EXTENT POSSIBLE. FABRICATE ACCORDING TO AISC'S "CODE OF STAND
STEEL BUILDINGS AND BRIDGES" AND AISC 360. mVI
DaWsEn97nccdnp
5082 E HAMPDEN AVE; SUITE 145
DENVER, CO 80222
(303) 2241234
GENERAL NOTES
TITLE:
STRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT
4250 BALSAM STREET -
WHEAT RIDGE, COLORADO 80033
:� 33741 _
OCT 11, 2020
FOR AND ON BEHALF OF DAMS ENGINEERING CONSULTANTS, LLC
SHEET NO:
S0.06
PROJECT NO. DEC21082020-01 I- ISCALE: NONE (DATE: OCT 11,2020
t W heat
o p
UCrTUURR_AL WOOD FRAMING - GENERAL
�%a/ry9 D�FALL BE WHERE
NOTED NO. OTHERWISI OR E, ALL 2" NOMINAL LUMBER SHALL POSTS SHALL BE HEM -FIR NO. 2 OR BETTER. ALL SOLID TIMBER BEAMS AND POSTS
2. ALL HEADER LINTELS AND BEAMS SHALL BE (3) 2x10 HEM -FIR #2 OR BETTER UNLESS OTHERWISE NOTED. MULTIPLE MEMBERS. SHALL BE GLUED AND NAILED
TOGETHER WITH I Od @16" O.C. FOR (2) MEMBERS AND 16d O.C. FOR (3) MEMBERS - UNLESS OTHERWISE NOTED.
3. PROVIDE (2) 2X4'S OR (2) 2X6'S MINIMUM AT EACH OF THE BEAMS AND HEADERS UNLESS NOTED. OTHERWISE.
4. LAMINATED VENEER LUMBER (LVL) SHALL HAVE THE FOLLOWING MINIMUM ALLOWABLE STRESSES: FLEXURAL STRESS = 2600 PSI, MODULUS OF ELASTICITY
= 1.9X10 (6) PSI, HORIZONTAL SHEAR PERPENDICULAR TO GLUE UNE = 285 PSI.
S. METAL FRAMING CONNECTOR DESIGNATIONS ARE THOSE MANUFACTURED BY SIMPSON STRONG -TIE COMPANY AND SHALL BE INSTALLED IN ACCORDANCE
WITH THEIR RECOMMENDATIONS TO DEVELOP THE RATED CAPACITY.
6. PROVIDE FULL HEIGHT SOLID BLOCKING (MINIMUM WIDTH TO MATCH WIDTH OF FRAMING) BETWEEN ALL JOISTS AND RAFTERS. PROVIDE SOLID BLOCKING OR
1"X4" CROSS -BRIDGING AT 8' O.C. MAXIMUM SPACING FOR ALL SOLID SAWN JOISTS AND RAFTERS.
7. OPENINGS, POCKETS, ETC., SHALL NOT BE PLACED IN BEAMS, JOISTS, RAFTERS, STUDS, POSTS, COLUMNS, TIMBERS AND OTHER STRUCTURAL MEMBERS.
UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS OR APPROVED BY THE STRUCTURAL ENGINEER,
8. WOOD STRUCTURAL PANELS SHALL CONFORM TO APA DESIGN AND THE SPECIFICATIONS IN THE NDS, LATEST EDITION AND SHALL BE CONTINUOUS OVER
THREE ADJACENT SPANS MINIMUM.
9. ALL ROOF SHEATHING SHOULD CONSIST OF e" APA RATED SHEATHING, EXPOSURE I, IDENTIFICATION NO. 32/16. NAIL WITH 1 Od NAILS AT 6" OC AT PANEL
EDGES AND 12" OC ALONG INTERMEDIATE SUPPORTS.
10. PLACE BLOCKING UNDER ALL POSTS AND OTHER POINT LOADS TO PROVIDE CONTINUOUS SUPPORT DOWN TO THE FOUNDATION.
11, UNLESS NOTED OTHERWISE ALL NAILS SHALL BE COMMON NAILS WITH SIZES SHOWN ON THE DRAWINGS. UNLESS NOTES OTHERWISE, ALL NAILING SHALL BE
IN ACCORDANCE WITH TABLE R602.3(1) OF THE IRC.
FOUNDATION DRAIN (IF APPLICABLE)
1. THE FOUNDATION DRAIN SHOULD CONSIST OF A 3" DIAMETER PERFORATED PIPE, EMBEDDED IN FILTER FABRIC AND FREE DRAINING GRAVEL PLACED IN A
TRENCH AT LEAST 12 INCHES IN WIDTH. FREE DRAINING GRAVEL OR CRUSHED STONE SHALL CONTAIN NOT MORE THAN 10% MATERIAL PASSING A NO. 4
SIEVE. TRENCH SHOULD BE OFFSET FROM EDGE OF NEAREST FOUNDATION BY 12 INCHES AND PROVIDE POSITIVE DRAINAGE TO SUMP PIT, DRAIN PIPE SHALL
SLOPE TOWARD PIT AT A MINIMUM OF 1/8- PER FOOT. THE PIPE SHALL BE PLACED ON NOT LESS THAN 21NCHES OF GRAVEL AND COVERED WITH NOT LESS
THAN 6 INCHES OF THE SAME MATERIAL. IN ADDITION, THE TRENCH SHOULD BE LOCATED SUCH THAT A VISUALIZED LINE EXTENDING DOWNWARD AT A 45
DEGREE ANGLE FROM THE FOOTING DOES NOT INTERSECT THE NEAREST EDGE OF THE TRENCH EXCEPT WHERE DRAIN PASSES THE FOOTING TO THE PIT.
2. SUMP PIT SHALL BE DRAINED WITH A PUMP THAT DISCHARGES OR FREE DRAINS AWAY FROM THE FOUNDATION. PROVIDE AN OVERFLOW ALARM.
REMEDIAL PIERS
REMEDIAL PIERS SHOWN ARE TO CONSIST OF RESISTANCE PIERS OR MICRO PILES. REFER TO MOST
SPECIFICATIONS AND REQUIREMENTS REGARDING PLACEMENT OF THE PIERING SYSTEMS. SPECIFIC
ENGINEER OF RECORD.
2. ALL PIERS/ANCHORS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND
3. INSTALLING CONTRACTOR TO BE AN APPROVED CERTIFIED INSTALLER OF THE PIERS/ANCHORS APPROVED
fav .SngimerIng
5082 E HAMPDEN AVE, SURE 145
GENERAL NOTES
TITLE:
STRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT- - -
4250 BALSAM STREET
WHEAT RIDGE, COLORADO 80033
NICA DING INSTALLATION,
17" IR OVED BY THE
"� ASTER o9 T���o
r5�s. N °
�cENT33741 _ a
j Oct "
SS ANAL
OCT 1 1, 2020
FOR AND ON BEHALF OF DAMS ENGINEERING CONSULTANTS, LLC
SHEET NO:
S0.07
PROJECT NO. DEC21082020-01 _ I SCALE: NONE _ DATE; OCT 11, 2020
ls� STRUCTURAL STEEL
G2Xa1179 f\TTRUCTURAL STEEL: MINIMUM YIELD STRENGTH 35 KSI (ASTM A53) FOR PIPES; 46 KSI FOR TUBES; 50 KSI A572 FOR ALL WIDE FLANGE (W) AND
- - TEE (WT) SHAPES; 36 SKI ALL ELSE, UNLESS NOTED OTHERWISE.
2. ALL BOLTS SHALL CONFORM TO ASTM A325, EXPECT ANCHOR BOLTS WHICH SHALL CONFORM TO ASTM A307 UNLESS NOTED OTHERWISE ON PLANS
OR DETAILS.
3. MINIMUM WELDS; AISC SPECIFICATION, NOT LESS THAN 3/16" FILLET CONTINUOUS UNLESS OTHERWISE NOTED.
A. WELD SIZES AND LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZES IF GAPS EXIST AT THE FACING
SURFACE.
B. WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY AISC J2.1.B AND J2.2.B.
4. WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE A.W.S. QUALIFICATION TESTS.
STRUCTURAL STEEL MATERIAL
PROVIDE THE FOLLOWING UNLESS NOTED
A. WIDE FLANGE AND WT SHAPES: ASTM A9921A992M GRADE 50 (345 - Fy = 50 KSI)
B. HOLLOW STRUCTURAL SECTION (HSS):
1. ROUND ASTM A53/A53M TYPE E OR S GRADE 'B'- Fy = 35 KSI
2. RECTANGULAR ASTM A500 GRADE 'B' - Fy = 46 KSI
C. S, M, HP SHAPES, ANGLES, CHANNELS, AND OTHER STEEL NOT IDENTIFIED: ASTM A36/A36M - Fy = 36 KSI
D. PLATES AND BARS ASTM A36/A36M - Fy = 36 KSI
CONNECTION MATERIAL
F1554 ANCHOR RODS AND BOLTS HAVE A SMALLER DIAMETER THAN STANDARD BOLTS. THIS SHOULD BE CONSIDERED IF USING THE BOLT IN BENDING.
A. ANCHOR RODS: ASTM F7554 GRADE 55 WELDABLE, PLAIN - Fy = 55 KSI UNLESS NOTED OTHERWISE. PROVIDE HEAVY HEX HEADED RODS OR
EQUIVALENT HEAVY HEX BEARING NUT TACK WELDED UNLESS NOTED OTHERWISE.
B. HIGH-STRENGTH BOLTS: ASTM A325 (OR A4901 OR ASTM F1852 TENSION -CONTROL TYPE i HEAVY HEX, PLAIN UNLESS NOTED OTHERWISE. PROVIDE
TENSION -CONTROL BOLTS WHEN EVER POSSIBLE.
C. WELDING ELECTRODES: AWS D1.1, E70XX ELECTRODES UNLESS NOTED OTHERWISE.
D. HEADED ANCHOR STUDS (H.D.A.SJ ASTM A108 AND AWS D 1.1 TYPE B - Fy = 50 KSI.
STUDS SHALL BE AUTOMATICALLY END WELDED IN SHOP WHERE POSSIBLE. FOR COMPOSITE CONSTRUCTION, CONNECTORS SHALL BE FIELD
WELDED THROUGH THE METAL DECK.
E. DEFORMED ANCHOR STUDS (DAS): ASTM A496 AND AWS D1.1 - Fy = 70 KSI.
F. EXPANSION ANCHORS: WEDGE TYPE, REFER TO SPECIFICATIONS FOR MATERIAL, GRADE, AND FINISH. SUBMIT ICBO REPORT.
G. ADHESIVE ANCHORS: THREADED ROD ASTM A307, REFER TO MANUFACTURER'S SPECIFICATIONS FOR MATERIAL GRADE AND FINISH.
H. SLEEVE ANCHORS: SIMPSON SLEEVE ALL OR EQUIVALENT, SUBMIT ICBG REPORT.
I. SCREW ANCHOR: SIMPSON TITEN HD OR EQUIVALENT, SUBMIT ICBO REPORT.
STRUCTURAL STEEL INSTALLATION
A. ALL HIGH STRENGTH BOLTS USED IN COLUMN SPLICES, CONNECTIONS OF BEAMS AND GIRDERS TO COLUMNS, AND WHERE NOTED ON THE DRAWINGS
AS TYPE "SC" OR OTHER TYPE FOLLOWED BY -T-,, SHALL BE TENSIONED TO THE VALUES OF TABLE J3.7 OF "SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS, ASD," BY AISC. OTHER HIGH-STRENGTH BOLTS MAY BE INSTALLED SNUG TIGHT AS DEFINED BY AISC.
CONNECTION DESIGN
PROVIDE CONNECTIONS AS SHOWN IN THE STEEL BEAM CONNECTION SCHEDULE AND DETAILS HEREIN. PROVIDE 7/8" DIAMETE OIRK
CONNECTIONS UNLESS OTHERWISE NOTED. CONTACT ENGINEER FOR ALTERNATIVES AND OR ADDITIONAL INFORMATION RE CQNWEET
SHOWN. O°°° -p-
WELDING REQUIREMENTS O"^�
_ e
A. WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE A.W.S. QUALIFICATION
FICATION TESTS. "0 ^� W
B. MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16" FILLET, CONTINUOUS UNLESS OTHERWISE NOTED°?W
1. WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE WEL IF^GAPS EXIST AT
FAYING SURFACE.
2. WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY AISC ASD -1989; J2.1.b AND J2.2.b. S/ ONAL
C. ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED.
OCT 11, 2020
GENERALNOTES FOR AND ON BEHALF OF DAVIS ENGMERING CONSULTANTS,LLC
TITLE: SHEET NO:
dpc STRUCTURAL REPAIR AND MODIFICATION PLANS O
DavisEnginEcring BALSAM STREET PROJECT S O. O o
5082 E HAMPDEN AVE, SUITE 145
DENVER, CO 80222 4250 BALSAM STREET
(303) 229-1234 WHEAT RIDGE, COLORADO 80033
PROJECT NO. DEC21082020-01 SCALE; NONE DATE; OCT 11. 2020
t W heat
o -p;
U� m
ONCRETE g.
Gey ,
p.Np�� �,,gg�o
a✓O9 tlVORK SHALL CONFORM TO ACI 301 (CURRENT VERSION). ALL STRUCTURAL CONCRETE TO BE FROM TYPE 1 PORTLAND CEMENT, STONE AGGREGATE, AND
-- -DEVELOP 3000 PSI MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS. SLAB -ON -GRADE SHALL DEVELOP 3000 PSI MINIMUM COMPRESSIVE STRENGTH AT 20
DAYS. SLUMP OF CONCRETE SHALL NOT EXCEED 4" UNLESS A HIGH RANGE WATER -REDUCING ADMIXTURE IS USED, THE SLUMP OF CONCRETE PRIOR TO
ADDITION OF A HIGH RANGE WATER -REDUCING ADMIXTURE SHALL NOT EXCEED 4". THE SLUMP OF CONCRETE CONTAINING A HIGH RANGE WATER -REDUCING
ADMIXTURE SHALL NOT EXCEED 10". AIR CONTENT SHALL BE BETWEEN 5 AND 7 PERCENT. NO HORIZONTAL CONSTRUCTION JOINTS SHALL BE MADE IN SLABS
OR BEAMS.
2. ALL CONCRETE SLABS -ON -GRADE TO HAVE CONTROL JOINTS AT LOCATIONS SHOWN ON PLAN. THE OWNER IS HEREBY MADE AWARE OF THE CHANCE OF
MOVEMENT AND CRACKING OF SLABS PLACED ON COMPACTED FILL OR NATIVE SOILS. THE RISKS OF SWELLING SOILS AND RESULTING HEAVING/CRACKING OF
CONCRETE CAN BE MINIMIZED BUT NOT ELIMINATED WITH CAREFUL CONSTRUCTION AND MAINTENANCE PROCEDURES.
3. FOUNDATION ANCHOR BOLTS SHALL BE 112" DIAMETER X 12" AND SPACED AT 4'-O" O.C. AND 12" FROM EACH SIDE OF A CORNER AND 6" FROM THE END OF A
SPLICE IN THE MUDSILL. PROVIDE A 3/4" CHAMFER AT ALL EXPOSED EDGES OF CONCRETE IN ACCORDANCE WITH ACI 301 SECTION 4.2.4 UNLESS NOTED
OTHERWISE. PROVIDE SLEEVES FOR PLUMBING AND ELECTRICAL OPENINGS PRIOR TO PLACING CONCRETE. DO NOT CUT REINFORCEMENT THAT MAY CONFLICT.
AVOID CUTTING EXISTING REBAR WHEN DRILLING HOLES IN FORMED CONCRETE.
4. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60 AND HAVE A MINIMUM OF 60,000 PSI YIELD STRENGTH. LAP SPLICES, WHERE PERMITTED BY THE
ENGINEER, SHALL RE MINIMUM OF 74 BAR DIAMETERS, WHERE PERMITTED, SPLICES MAY BE CLASS B CONTACT SPLICES.
5.
6. CONCRETE: NORMAL WEIGHT AGGREGATE, DEVELOP 3000 PSI MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS.
REINFORCEMENT PROTECTION
A. CONCRETE PLACED AGAINST EARTH....................3"
B. CONCRETE PLACED IN FORMS BUT EXPOSED TO WEATHER OR
EARTH:
1. BARS #5 AND SMALLER ................................... 1-i"
2. BARS LARGER THAN#5...................................2"
C. COLUMNS,GIRDERS, GRADE BEAMS, BEAMS........... 1-1/2"
D. SLABS OR WALLS NOT EXPOSED TO WEATHER OR EARTH:
1. BARS#11 AND SMALLER ................................... 1"
2. BARS LARGER THAN #11 ................................... 1-1/2'
4. REINFORCING PLACING TOLERANCES: PER IRC 2018.
5. DETAILS BARS IN ACCORDANCE WITH THE LATEST EDITIONS OF "ACI DETAILING MANUAL", PUBLICATION SP -66, AND "BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE", ACI 318.
6. AT SPLICES LAP BARS 36xDIAMETER. MAKE BARS CONTINUOUS AROUND CORNERS OR PROVIDE MATCHING CORNER BARS.
7. PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING AT POSITIONS SHOWN ON PLANS. ALL DOWELS, BOLTS, AND EMBEDDED PLATES
SHALL BE SET AND TIED IN PLACE BEFORE THE CONCRETE IS POURED. "STABBING" DOWELS, BOLTS OR PLATES INTO PREVIOUSLY PLACED CONCRETE IS NOT
PERMITTED.
S. PLACE 245 U EACH FACE) WITH 2'-0" PROJECTIONS AROUND OPENINGS IN CONCRETE. IN SLABS -ON -GRADE AND FLOOR TOPPING SLABS, OPENINGS LARGER
THAN 12" IN ANY DIMENSION SHALL BE REINFORCED WITH 1-#4X 4 4'-0" PLACED DIAGONALLY TO EACH CORNER.
9. HORIZONTAL CONSTRUCTION JOINTS SHALL NOT BE PERMITTED IN WALLS UNLESS SHOWN ON THE STRUCTURAL DRAWINGS.
10. CONTINUOUS TOP AND BOTTOM BARS IN WALLS, BEAMS, AND GRADE BEAMS SPLICED AS FOLLOWS:
A. TOP BARS - AT MIDSPAN
B. BOTTOM BARS - OVER SUPPORT
11. WIRE FABRIC REINFORCEMENT: LAP ONE AND ONCE HALF MESH SPACES AT SPLICES AND WIRE TOGETHER.
MESH AT POSITION SPECIFIED.
-- -- 5082 E HAMPDEN AVE, SUITE 145
DENVER, CO 80222
(303) 229-1234
GENERAL NOTES
TITLE:
STRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT - - -
STREET
COLORADO 80033
�� REGIS e
Q''O�w�"STER �//T��
DRIES TO I`Jmp
oma 33741 _g Y
0=O
T e °
e �
S�ONAL
OCT 11, 2020
FOR AND ON BEHALF OF DAMS ENGINEERING CONSULTANTS, LLC
SHEET NO:
S0.09
PROJECT NO. DEC21082020-01 IISCALE: NONE (DATE: OCT11,2020
t W heat
o -p;
�Xazry9
MBREIMTIMIS
swMS UEGEID
0
AT OR AROMO
ADD'L
ADDITIONAL—
X —
GRID ENE -XI
ASSY
ASSEMBLY
SOC
BOTTOM OF CONCRETE
BOS
BOTTOM OF STEEL
MG
BEARING
COL
COLUMN
CONIC
CONCRETE
DEMO
DEMOLISH/REMOVE AND PROPERLY DISPOSE OF
—
WORMLLTREM,X,
OFT
DRYFLMTHDXNESS
O
DT
D"I-E TEE
E/W
EAST/WEST
E.C.
EPDXY COATED
SECTION CLT V ON SHEET "SH.N'
EOR
ENGINEER OF RECORD
E.S.
EACH SIDE
E.W.
EX
EACH WAY
EMSHNG
=
SUBGRADE
(E)
EXISTING
EXP
EXPANSION
Q —
DRAWING REVISION" N'
F.O.
FACE OF
F.V.
CONTRACTOR FIELD VERIFY
END
FOUNDATION
—
CURRENT REVISION
FS
FAR SDE
GAL
GALLON
GPR
GROUND PENETRATING RADAR
LF
LINEAL FEET
LVL
LAMINATED VENEER I-MBER
SLOPE
(N)
NEW
N/S
NORTH/SOUTH
NS
AFAR SIDE
NS/FS
NEAR SIDE AND FAR SIDE
7� =
STEPNTOPOF
O.C.
ON CEI SPACING
jT7/
CONCRETE
OPNG
OPENNG
PL
PLATE
PSI
POUNDS PER SQUARE INCH
PSF
POUNDS PER SOIARE FOOT
RCP
REFLECTED CEEING PLAN
O =
EXISTING &ISH OR OTHER
RE:
REFER TO
MAJOR VEGEFAAON
ROMPS
REQUIREMENTS
SF
SQUARE FEET
SIM
SIMILAR CONSTRUCTION CONVRIONS
sm
SLABON GRADE
SID
STANDARD
S1L
STEEL
_
TREE (CONIFEROUS)
SS
STAINLESS STEEL
T&B
TOP AND BOTTOM
TEMP
TEMPORARY
TOC
TOP OF CONCRETE
TOS
TOP OF STEEL
TOW
TCPOF WALL
_
TREE (DECIDUOUS)
TP
TYPICAL
U.N.O.
UNLESS NOTED OTHERWSEW
W./ P.
MITI
WORK POW
(�
O REUP//�� /S
WWF
WELDED WIRE FABRIC
11J�
N
o� 33741 _C
o .�
T
PLAN NOTES
OCT 1 1, 2020
FOR AND ON BEHALF OF DAMS ENGINEERING CONSULTANTS, LLC
TITLE: SHEET NO:
STRUCTURAL REPAIR AND MODIFICATION PLANS
DavosEn97n wE slog BALSAM STREET PROJECT
J V C`('� i O
5082 E HAMPDEN AVE, SUITE 145 4250 BALSAM STREET I_
DENVER, CO 80222
(303) 229-1234 WHEAT RIDGE, COLORADO 80033
PROJECT NO. DEC21082020-01 II SCALE: NONE I DATE: OCT -11,2020
of W heat
o
(E) CRAWLSPACE AREA
(N) 36"x36"x12"ISOLATED
GONG FOOTING -INSTALL
UNDER LOCATION OF
COLUMN FROM ATTIC
BEAM ABOVE - VERIFY
LOCATION IN FIELD
(N) 3" DIA ADJUSTABLE
STANDARD STEEL PIPE
COL (7.58 PLT) -
CENTER ON (N)
CONCRETE PAD - AS
SHOWN
I
1
1
I
1
m
0
13
I
v
1
C
PLAN NOTES
1. ALL DIMENSIONS AND LOCATIONS OF BUILDING AND PROPERTY ELEMENTS ARE TO BE FIELD
DETERMINED BY CONTRACTOR.
2. ANY AND ALL CONSTRUCTION SHORING REQUIRED DURING THE PROPOSED SCOPE OF WORK IS THE
RESPONSIBILITY OF THE CONTRACTOR.
3. IT SHOULD BE NOTED THAT, THESE PLANS ARE BASED ON VISIBLE OBSERVATION OF THE
STRUCTURAL ISSUES AND THE FOUNDATION MOVEMENT THAT HAS OCCURRED.
4. THE INSTALLATION OF ALL REMEDIAL STRUCTURAL REPAIRS AND ELEMENTS JS TO COMPLY WITH
MANUFACTURER'S REQUIREMENTS AND THE 2018 IRC.
5. ALL BUILDING ELEMENTS SHOWN ARE INTENDED FOR REPRESENTATION PURPOSES ONLY. NO
i
(E) GONG
FOUNDATION WALL
AND FOOTING -
TYP
(N) INTERIOR CONCRETE PADS/FOOTINGS ARE TO REST
ON NATIVE MATERIAL OR PROPERLY
COMPACTED/TESTED FILL - WE SHOULD BE CONTACTED
TO OBSERVE EXCAVATIONS FOR (N) FOUNDATION 1
ELEMENTS PRIOR TO PLACING STEEL OR POURING
CONCRETE - TYP
1
1
1
m
1 0
1 3
1
(E) CONIC
FOUNDATION FOR
FIREPLACE
ASSEMBLY
I
(E) INTERIOR CONE
BEAM SUPPORTS -
TYP
(E) CRAWLSPACE AREA
(E) CRAWLSPACE AREA
(E) GONG
FOUNDATION WALL
AND FOOTING -
TYP
(N) 12" DIA GONG PIER - PIER
MUST REST ON NATIVE
MATERIAL OR PROPERLY
COMPACTED FILL - PIER MUST
EXTEND TO 36" BELOW GRADE
FOR FROST PROTECTION
(N) 6x6 PT COLUMN - CEDAR
COLUMN MAY BE USED -
CENTER COL ON PIER - FIELD
VERIFY LOCATION
RESPONSIBILITY IS TAKEN FOR ELEMENTS THAT WERE NOT READILY VISIBLE AT THE TIME OF OUR
REVIEW,
6. CONTRACTOR IS RESPONSIBLE FOR All COORDINATING ALL U DUTY LOCATES IF APPLICABLE
7. WE SHOULD BE CONTACTED TO PERFORM COMPLIANCE OBSERVATIONS OF THE REMEDIAL WORK
OMISSION OR ADDITION OF STRUCTURAL SUPPORTS IS TO BE DETERMINED BY THE ENGINEER OF
RECORD. ADDITIONAL STRUTS MAY BE REQUIRED - THIS WILL BE DETERMINED BY THE ENGINEER AT
THE TIME OF THE COMPLIANCE OBSERVATIONS.
B. ONCE REPAIRS ARE COMPLETER EXTERIOR GRACING SHOULD BE RE-ESTABUSHED. MAINTAIN 5%
MINIMUM SLOPE AWAY FROM THE EXISTING FOUNDATION FOR A MINIMUM OF 10 FEET.
9. THIS REPAIR DOES NOT INCLUDE ANY OTHER PORTIONS OF THE FOUNDATION OR RESIDENCE -
ADDITIONAL DAMAGED WERE NOTED AT OTHER AREAS OF THE FOUNDATION, HOWEVER ARE NOT
INCLUDED IN THIS SCOPE OF WORK.
1
(E) SLAB
ON GRADE
(E) GONG
FOUNDATION WALL
AND FOOTING -
TYP
FOUNDATION PLAN
10. DAVIS CRUNCHING CONSULTANTS, LLC DOES NOT ACCEPT ANY RESPONSIBIMY FOR THE FUTURE
PERFORMANCE OF THE FOUNDATION AND/OR THE IMPLEMENTED REPAIR. THIS DESIGN HAS BEEN
COMPLETED IN ACCORDANCE WITH PERTINENT STANDARDS, TYPICAL DESIGN SOIL PARAMETERS,
AND EXCEPTED ENGINEERING DESIGN PROCEDURES, AND IS BASED ON THE BEST INFORMATION
AVAILABLE AT THE TIME OF COMPLETION. THE DESIGN IS INTENDED TO MINIMIZE THE DIFFERENTIAL
MOVEMENT RESULTING FROM MOISTURE -INDUCED MOVEMENT OF EXPANSIVE SOIL CAUSED BY
SEASONAL MOISTURE CHANGES. R MUST BE RECOGNIZED THAT FOUNDATION COMPONENTS, AND
IN PARTICUTAR, FLOOR STABS AND OTHER FIATWORK, WILL UNDERGO MOVEMENT, ADHERENCE TO
THOSE DETAILS ISOLATING FLOOR SI VIS FROM COLUMNS, WALLS, PARTITIONS OR OTHER
STRUCTURAL COMPONENTS IS EXTREMELY IMPORTANT IF DAMAGE TO THE SUPERSTRUCTURE IS TO
BE MINIMIZED. ANY SUBSEQUENT OWNERS SHOULD BE APPRISED OF THE EKPANSIVE SOIL
CONDITIONS, IF ANY, AND ADVISED TO MAINTAIN GOOD PRACTICES IN THE FUTURE WITH REGARD
TO SURFACE AND SUBSURFACE DRAINAGE, FRAMING OF PARTITIONS ABOVE FLOOR SLABS,
DRYWALL AND FINISH WORK ABOVE FLOOR SLABS, ETC. -- -
Is,
Lmmxam.lmhelm..
ft"be/ampuAg.
C
1w
OCT11 2020
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
Na
J
LL
Z
O
Q
V
LL
M
O
�
O
m
�
2 w
Q
ama
F- K
w0
a
No
2w
U<
Q
mu
tNm
v2
N
L�
of W heat
U ^^
c
CN -P
0
(N) (4) 2x4 COL -
o
INSTALLINFRAMED
WALL - EXTEND TO
1
TOP OF (E) END WALL
I w
BELOW
W� jON
O
IJ
d+
�j V
1,
�L
x
(3) 1-a'x14°LVL (1.
I
I
52.01 1
TYP I
i
I
I
1
(N) 3' DIA ADJUSTABLE 1
STANDARD STEEL PIPE I
COL (7.5BPLF) -
INSTALL IN (E) FRAMED
WALL - AS SHOWN
EXTENT OF
ROOF
OVERHANG-
TYP
(E) FRAMED
WALLS - TYP
SIVPSON
HGLTV5.514
HANGER OR
APPROVED EQUAL
(E) FRAMED
WALLS - TYR
PLAN NOTES
1. ALL DIMENSIONS AND LOCATIONS OF BUILDING AND PROPERTY ELEMENTS ARE TO BE FIELD
DETERMNED BY CONTRACTOR.
2. ANY AND ALL CONSTRUCTION SHORING REQUIRED DURING THE PROPOSED SCOPE OF WORK IS
THE RESPONSIBILITY OF THE CONRRACTOR.
3. IT SHOULD BE NOTED THAT, THESE PLANS ARE BASED ON VISIBLE OBSERVATION OF THE
STRUCTURAL ISSUES AND THE FOUNDATION MOVEMENT THAT HAS OCCURRED.
4. THE INSTALLATION OF ALL REMEDIAL STRUCTURAL REPAIRS AND ELEMENTS IS TO COMPLY
WITH MANUFACTURER'S REQUIREMENTS AND THE 2018 IRC
5. ALL BUILDING ELEMENTS SHOWN ARE INTENDED FOR REPRESENTATION PURPOSES ONLY. NO
RESPONSIBILITY S TAKEN FOR ELEMENTS THAT WERE NOT READILY VISIBLE AT THE TIME OF -
(E)FRAMED
WALL AND END
WALL BELOW -
TYP
SUPPORT ENDS OF (N) LVL ROOF
SUPPORT BEAMS INTO (E) STEEL
MASONRY WALLS OF CHIMNEY -
MIN OF 4" BEARING - WRAP END
OF BEAM - BEAM MUST BEAR ON
SOLID STRUCTURALLY SOUND
MATERIAL - VIF
(t) ME
ASSEMI
(E) PORTION (
FRAMED WALL TO I
REMOVED ONCE (I
ROOF SUPPOF
FRAMING IS INSTALL(
(E) PORTION OF
FRAMED WALL TO BE
REMOVED ONCE (N)
ROOF SUPPORT
FRAMING IS INSTALLED
(N) (3) 1 -J -x14' LVL ILSE)
RIDGE (ABOVE)
OUT REVIEW,
6. CONTRACTOR S RESPONSIBLE FOR ALL COORDINATNG ALL UTILITY LOCATES, IF APPLICABLE
7. WE SHOULD BE CONTACTED TO PERFORM COMPLIANCE OBSERVATIONS OF THE REMEDIAL
WORK OMISSION OR ADDITION OF STRUCTURAL SUPPORTS IS TO BE DETERMINED BY THE
ENGINEER OF RECORD. ADDITIONAL STRUTS MAY BE REQUIRED -THIS WILL BE DETERMINED BY
THE ENGINEER AT THE TIME OF THE COMPLIANCE OBSERVATIONS.
8. ONCE REPAIRS ARE COMPLETED, EXTERIOR GRADING SHOULD BE RE-ESTABLISHED. MAINTAIN
5%MMMUM SLOPE AWAY FROM THE EXISTING FOUNDATION FOR A MINIMUM OF 10 FEET.
9. THIS REPAIR DOES NOT INCLUDE ANY OTHER PORTIONS OF TIE FOUMDATIDNORRESIDENCE
-
ADDITIONAL DAMAGED WERE NOTED AT OTHER AREAS OF THE FOUNDATION, HOWEVER ARE
- NOT INCLUDED IN THIS SCOPE OF WORK.
(E) PORTION OF FRAMED
WALL TO BE REMOVED ONCE
(N) ROOF SUPPORT FRAMING
IS INSTALLED- BOTTOM
HALF OF WALL TO REMAIN -
VIF WITH OWNER
(N) (4) 2.4 COL -
INSTALL IN FRAMED
WALL- EXTEND TO
TOP OF (E) END WALL
BELOW
(N) (3) 1 -="x14 -LVL (1.9E) —
RIDGE (ABOVE)
(M 3' DIA ADJUSTABLE
STANDARD STEEL PIPE
COL (7.58 PLR) -
INSTALL IN (E) FRAYED
WALL - EXTEND TO TOP
OF (E) END WALL BELOW
CEILING FRAMING PLAN
1"=1"-0' -*%.�
1D. DAVIS ENGINEERING CONSULTANTS, LLC DOES NOT ACCEPT ANY RESPONSIBILITY FOR THE
FUR/RE PERFORMANCE OF THE FOUNDATION AND/OR THE IMPLEMENTED REPAIR, THIS DESIGN
HAS BEEN CONPLETED IN ACCORDANCE WITH PERTINENT STANDARDS, TYPICAL DESIGN SOL
PARAMETERS, AND EXCEPTED ENGINEBRING DESIGN PROCEDURES, AND IS BASED ON THE BEST
INFORMATION AVAILABLE AT THETME OF COMPLETION. THE DESIGN IS INTENDED TO MNIMIZE
THE DEFERENTIAL MOVEMENT RESULTING FROM MOISTURE -INDUCED MOVEMENT OF
EXPANSIVE SOL CAUSED BY SEASONAL MOISTURE CHANGES. IT MUST BE RECOGNIZED THAT
FOUNDATION COMPONENTS, AND IN PARTICUAR, FLOOR SLABS AND OTHER FLATWORK, WILL
UNDERGO MOVEMENT. ADHERENCE TO THOSE DETAILS ISOLATING FLOOR SLABS FROM
COLUMNS. WALLS, PARTITIONS OR OTHER STRUCTURAL COMPONENTS IS EXTREMELY
IMPORTANT IF DAMAGE TO THE SUPERSTRUCTURE IS TO BE MINIMIZED, ANY SUBSEQUENT
OWNERS SHOULD BE APPRISED OF THE EXPANSIVE SOIL CONDITIONS, R ANY, AND ADVISED TO
MANTAN GOOD PRACTICES IN THE FUTURE WITH REGARD TO SURFACE AND SUBSURFACE
DRAINAGE, FRAMING OF PARTITIONS ABOVE FLOOR SLABS, DRYWALL AND HEIGH WORK ABOVE
FLOOR SLABS, ETC.
LET FRAMED
WALL AND FND
WALL BELOW -
TYP
�QU f�C(e/S
ST ER
33741
e d
a
o
o
0
EXTENT OF
� �rNim
m
FI
C i
W� jON
O
111'!
d+
�j V
N
�L
N
W'
�go
m
w�
O
TYR
0
O
0
om
0
Z
N
w
O
ii
Z
EXTENT OF
Q
Z
ROOF
F
w
OVERHANG-
m
TYR
0
O
0
om
Z
zdw
a
moiOo¢
as
o
U
¢J¢
�W
Rn
K
<0
OQMF-
l -
F-
F
OCT 1 1, 2020
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
(9
z
J
va
EXTENT OF
Q
ROOF
w
OVERHANG-
p
TYR
Z
a
U
Rn
OCT 1 1, 2020
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
(9
z
J
va
of W heat
CD
0
c
G/jain9 D`'4\0
PLAN VIEW - FTG
N
GRADE 60 BARS AT 8"
CENTER — BOTH WAYS
(N) 3" DIA ADJ STANDARD STL
PIPE COL
(N) 3" DIA ADJUSTABLE
STANDARD STL
PIPE COL AND TOP BEARING
PLATE — q'0"x4"
SECTION - TOP OF COL
(N) J"x4"x4" STL BEARING PLATE — GROUT AS NECESSARY
TO PROVIDE A LEVEL BEARING SURFACE
— PLATES MAY BE INSTALLED DIRECTLY ON CONC PAD
— CONNECT PLATE TO CONIC PAD WITH (2) 'x5'TITAN
SD SCREWS — OPPOSITE CORNERS OF PLATE
SECTION - PAD
#4, GRADE 60 BARS AT W
PAD TO BE SUPPORTED ON NATME ON CENTER—BOTH WAYS (oto REGIS
SODS OR PROPQ Y COMPACTED \' "` T,�
STRUCTURAL FILL UOQ 5TEf 9 `�
N
-U a
L
pO 33741
L \
T
OCT 11, 2020
FOR AND ON BEHALF OF DAMS ERGIAEERING CONSULTANTS, LLC
FOUNDATION DETAIL
TITLE: SHEET NO:
STRUCTURAL REPAIR AND MODIFICATION PLANS
DavlsEnglnEsring BALSAM STREET PROJECT
JLC "') O O
5082 E HAMPDEN AVE, SUITE 145
DENVER, CO 80222 4250 BALSAM STREET
(303) 229-1234 WHEAT RIDGE, COLORADO 80033
PROJECT NO. DEC21082OZO-01 SCALE: NONE DATE: OCT 11, 2020
o! W heat
CD
0
c
G/jain9 D`'4
\0
(E) ix RIDGE BLOCK
i
(E) Zx ROOF JOISTS,
i
(N) 2x6 FRAMED WALL – STUDS @ 16"
OC – DOUBLE TOP PLATE AND DOUBLE
BOTTOM PLATE – AS SHOWN
– CENTER UNDER (E) ROOF RIDGE
ABOVE TO EXTENT POSSIBLE
SET ELEVATION OF
NORTH/SOUTH RIDGE
SUPPORT BEAM ABOVE (E)
CEILING JOISTS AND (E)
MECHANICAL ELEMENTS
U 1\CGI
c_STER
3 _ i
0 33741
(N) 2x6 RIDGE TIE – INSTALL ONE BETWEEN EACH JOIST
EITHER SIDE OF RIDGE BLOCK – EVERY JOIST – INSTALL
DIRECTLY UNDER (E) RIDGE BLOCK
` \• CONNECT (N) RIDGE TIE TO (E) JOISTS
WITH (6) TMBERLOCK SCREWS EACH SIDE
(N) A34 SIMPSON CLIP – ONE EACH BRACE
(N) (3) 1 y"x14"LVLBEAM
(1.9E) – INSTALL IN (E) ATTIC –
STRAPCEILING JOISTS TO BEAM
U WITH SIMPSON COIL STRAPPING
OR APPROVED EQUAL
(N) 2x4 BRACE AT 3' ON CENTER
TO TOP OF BEAM
1I_
z
N
4 !
OCT 11, 2020
FOR AND ON BEHALF OF DAVIS H INUERING CONSULTANTS, LLC
DaVasEdgl.1—
Illl 5082 E HAMPDEN AVE, SUITE 145
DENVER, CO 80222
(303) ZZ9-1234
PROJECT NO. DEC21082020-01
(E) CEILING JOISTS
CONNECT (N) BRACES
TO (E) JOISTS
WITH (6) 1 Od NAILS –
EACH BRACE
FRAMING DETAIL
TITLE:
STRUCTURAL REPAIR AND MODIFICATION PLANS
BALSAM STREET PROJECT
4250 BALSAM STREET
WHEAT RIDGE, COLORADO 80033
SCALE: NONE
SHEET NO:
S2.01
DATE: OCT 11, 2020
#3 TIES AT LOCATION
SHOWN
(N) 4X4 SUPPORT POST
AND SIMPSON EPB44 ELEVATED
POST BASE
- OR APPROVED EQUAL
#3 TIE IN
THE BOTTOM
- AS SHOWN
I
REINFORCE PIER WITH (3) #4
VERTICAL
BARS - AS SHOWN -
MAINTAIN 3" CLR
FROM INSIDE FACE OF FORMS
CONCRETE PATIO CAN BE
POURED UP TO TOP OF NEW
CONCRETE PIER
(E) EXTERIOR
GRADE
REINFORCE PIER WITH
(3) #4 VERTICAL
BARS - AS SHOWN
I I-1 11—I I
- RE: PLAN PIER TO REST ON NA
SOIL OR PROPER QQ °REG/
COMPACTED S IS
FILL O�°°TER�9GF
N=
o�
SHEET NO:
°CD 33741
STRUCTURAL REPAIR AND MODIFICATION PLANS
M ofLL
°
DavisEnglneering
o\
a
#3 TIES AT
5082 E HAMPDEN AVE, SUITE 145
4250 BALSAM STREET
LOCATION
n
SHOWN
#3 TIE IN
THE BOTTOM
- AS SHOWN
I
REINFORCE PIER WITH (3) #4
VERTICAL
BARS - AS SHOWN -
MAINTAIN 3" CLR
FROM INSIDE FACE OF FORMS
CONCRETE PATIO CAN BE
POURED UP TO TOP OF NEW
CONCRETE PIER
(E) EXTERIOR
GRADE
REINFORCE PIER WITH
(3) #4 VERTICAL
BARS - AS SHOWN
I I-1 11—I I
- RE: PLAN PIER TO REST ON NA
SOIL OR PROPER QQ °REG/
COMPACTED S IS
FILL O�°°TER�9GF
OCT 1 1, 2020
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
FOUNDATION DETAIL
N=
o�
SHEET NO:
°CD 33741
STRUCTURAL REPAIR AND MODIFICATION PLANS
p �Q
°
DavisEnglneering
o\
L�;(ONAL
°
5082 E HAMPDEN AVE, SUITE 145
4250 BALSAM STREET
OCT 1 1, 2020
FOR AND ON BEHALF OF DAVIS ENGINEERING CONSULTANTS, LLC
FOUNDATION DETAIL
PROJECT NO. DEC21082020-01 I I SCALE: NONE I DATE: OCT 11, 2020
TITLE:
SHEET NO:
STRUCTURAL REPAIR AND MODIFICATION PLANS
DavisEnglneering
BALSAM STREET PROJECT
02
5082 E HAMPDEN AVE, SUITE 145
4250 BALSAM STREET
.
DENVER, CO 80222
(303) 229-1234
WHEAT RIDGE, COLORADO 80033
PROJECT NO. DEC21082020-01 I I SCALE: NONE I DATE: OCT 11, 2020
PERMIT: '
�LJURESS:
INSPECTION RECORD
JOS CODE:
Inspection online form: hftP://www.ci-wheatridge.co.us/i I nspection
Cancellations must be submitted via thenlne form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the followingbusiness
mess
Foundation Inspections Date Inspector
102 Caissons / Piers Initials
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not our Concrete Prior To Approval Of The Above Inspections
Underground / Slab InspectionsDate Inspector
Comments
201 Electrical / Cable/ Conduit Initials Comments
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection Date Inspector
301 Rough Framing Initials
302 Wall Sheathing
303 Roof Sheathing —
304 Sheer Inspection
305 Insulation
306 Mid -Roof f
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
Comments
ugh Inspection (continued)
3 Rough Mechanical Residential
7 Rough Mechanical Commercial
8 Boiler / Furnace
9 Hot water tank
00 Drywall screw and Nail
t1 Moisture board / shower walls
22 Rough Grading
23 Miscellaneous
inal Inspections
02 Gas Meter Release
103 Final Electrical Residential
t04 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
410 Final Window/Door
411 Landscape/Park/Planning
412 Row/Drainage/Public Works
413 Flood plain Inspection
414 Fire Insp. / Fire Protection
415 Public Works Final
416 Storm Water Mgmt.
417 Zoning Final Inspection
418 Building Final Inspection
nnin
re
Note: All items must be completed and approved by lof the F FinabliBuildingWorksns'n
pectiondoeBuilding
snot
before a Certificate of Occupancy is issued. Approval
constitute authorization of occupancy.
Low Voltage permits please be sure that rough inspections are completed by the Fire District and
For L
Electrical low voltage by the Building Division. �\
Inspector I Comments
Date Initials
Inspector I Comments
Date Initials
Inspections from these entities shall be requested
one week in advance.
For landscaping and parking inspections please
call 303-235-2846
For ROW and drainage inspections please call
303-235-2861
For fire inspections please contact the Fire
Protection District for your project.
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: -
I L i`'+00�
Job Address: -L50 E� -T
Permit Number: 1101 () b01,22
❑ No one available for inspection: Time _M PM
Re -Inspection required: Yes (Njo
When corrections have been made, call to e -inspection at 303-234-5933
Date: itholn Inspector:11
DO NOT REMOVE THIS NOTICE
1
w
ON
1�0
❑ No one available for inspection: Time _M PM
Re -Inspection required: Yes (Njo
When corrections have been made, call to e -inspection at 303-234-5933
Date: itholn Inspector:11
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
Inspection Type:
Job Address:
Permit Number:
INSPECTION NOTICE
/i%1 z 0 ,//do r-
7 �
7�)_ S 01-3AIs'.9/,1 S i
-2-- 0 1'2 O
❑ No one available for inspection: Time r ? / j AM/PM
Re -Inspection required: Yes No
When corrections have been made, call for re-inspectio at 303-234-5933
Date: !'� _ ry Inspector:
Lr
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(03) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: �%i� l2�v r
Job Address: - /7 nit S
Permit Number: l� `7 �"O Z 71,
❑ No one available for inspection: Time / / %f AM/PM
�esl\lo Re -Inspection required: �
When corrections have been made, call for re-inspehfion at 303-234-5933
f 5
Date: i ' 1 f Inspector: wi
City of Wheat Ridge
r
Residential Roofing PERMIT - 201708023
PERMIT NO: 201708023 ISSUED: 10/05/2017
JOB ADDRESS: 4250 Balsam ST EXPIRES: 10/05/2018
JOB DESCRIPTION: Residential Re -roof to install GAF asphalt shingles - 33 sq Pitch = 4/12
*** CONTACTS ***
OWNER (303)517-8566 KELLEY FAMILY TRUST
SUB (303)993-6057 Adam Steinbach 100332 Precision Homes
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 8,720.99
FEES
Total Valuation 0.00
Use Tax 183.14
Permit Fee 188.45
** TOTAL ** 371.59
*** COMMENTS ***
*** CONDITIONS ***
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required for both the midroof and final inspections. The 3rd party inspection report AND
THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat
Ridge. The report MUST BE SIGNED by the Homeowner.
REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec.
R806. The installation of ridge venting requires the installation or existence of soffit
venting. For calculation purposes, one hat or turtle vent equal to one-half of one square
foot of opening.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name) roof
covering" is required to be on site at the time of final inspection.
Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be
required, the 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped
off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the
Homeowner.
11 � A , City of Wheat Ridge
Residential Roofing PERMIT - 201708023
PERMIT NO: 201708023 ISSUED: 10/05/2017
JOB ADDRESS: 4250 Balsam ST EXPIRES: 10/05/2018
JOB DESCRIPTION: Residential Re -roof to install GAF asphalt shingles - 33 sq Pitch = 4/12
I by my signature do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
perfo nd that all yf rloto be performed is disclosed in this document and or its' accompanying approved plans and specifications.
/L
Signatu e OWNER or CONTRACTOR (Circle one) Dat
I. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans
and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of C uilding Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Dane Lovett
2 i% 0 ��
From:
no-reply@ci.wheatridge.co.us
Sent:
Monday, October 2, 2017 2:43 PM
To:
CommDev Permits
Subject:
Online Form Submittal: Residential Roofing Permit Application
Follow Up Flag:
Follow up
Flag Status:
Completed
Residential Roofing Permit Application
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received and due to the volume of requests, time to process
varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR
PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE
AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if
your contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
Is this application for a Yes
residential roof?
How many dwelling units Single Family Home
are on the property?
PROPERTY INFORMATION
Property Address 4250 Balsam Street
Property Owner Name Joel Kelley
Property Owner Phone 303-517-8566
Number (enter WITH
dashes, eg 303-123-4567)
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
Applications cannot be
submitted without an
executed contract
attached below.
Attach Copy of Executed
Contract
joel@tlecc.net
Yes
Joel Kelley Signed.pdf
CONTRACTOR INFORMATION
Contractor Business Precision Homes
Name
Contractor's License 100332
Number (This is a 5 or 6
digit number for the City
of Wheat Ridge)
Contractor Phone 720-512-5474
Number (enter WITH
dashes, eg 303-123-4567)
Contractor Address 1900 Federal
(Primary address of your
business)
Contractor Email Address suzanne@precisionhomesofcolorado.com
Retype Contractor Email suzanne@precisionhomesofcolorado.com
Address
DESCRIPTION OF WORK
TOTAL SQUARES of 33�
the entire scope of work:
Project Value (contract 8720.99
value or cost of ALL
materials and labor)
Are you re -decking the
roof?
Is the permit for a flat
roof, pitched roof, or
No /
Pitched roof (2:12 pitch or greater)
74
both? (check all that
apply)
What is the specific pitch
of the PITCHED roof?
How many squares are
part of the PITCHED
roof?
Describe the roofing
materials for the
PITCHED roof:
Type of material for the
PITCHED roof:
Provide any additional
detail here on the
description of work. (Is
this for a house or
garage? Etc)
4:12
33
GAF Armorshield
Asphalt
This is for a house.
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
75
submit this application
and to perform the work
described above.
I attest that everything Yes
stated in this application
is true and correct and
that falsifying
information in this
application is an act of
fraud and may be
punishable by fine,
imprisonment, or both.
Name of Applicant Suzanne Tafoya
Email not displaying correctly? View it in your browser.
76
GocuSign Envelope ID: E1259139-165B-4639-AB39-90DEF83D97B5
..
PRECISION HOMES
Beth and Joel Kelley
Email Joel@tlecc.net
Billing Address 4250 Balsam St
Wheat Ridge
State CO
Insurance Comp AAA
1st Check Amount $16,823.64
2nd Check Amount $5,944.32 + Supplements
Project Contract
Office: (303) 993-6057
info@PrecisionHomesofColorado.com
PrecisionHomesofColoradoxom
Work
Cell 303-517-8566
Home
Delivery Address 4250 Balsam St
Zip 80033 City Wheat Ridge CO
State Zip 80033
Claim # 1002-07-4641
Special Instructions: First check due upon commencement of work. Second
check due at completion of all trades.
The owner does hereby employ Precision Homes, LLC Roilfng Division to do the following Scope of Work:
Roofing Scope: The roofs will be replaced per the AAA Insurance scope of work. All roofing components will be installed to local code
requirement using new materials. GAF Timberline ArmorShield II shingles in Pewter Gray will be used.
Non -roof Items: The gutters, pergola, siding, windows, garage door, swamp cooler and paint will be replaced as described in the
insurance scope of work.
Precision Homes is not completing any trades not explicitly listed in this contract. All supplemental funds released from AAA Insurance
to the policyholder will be released to Precision Homes.
Precision Homes, LLCROofing Divisioat shall commence the work to be performed within 15 days from the start date. The earliest build start
date is for 3o days after the acceptance of this contract. This will allow for material deliveries and proper notification of all tenants. Time being of
the essence of this contract.
Acceptance of Proposal: The above terms and conditions and those contained on the reverse side are satisfactory and herby accepted. You are authorizing Preci-
vinrl Homes. LLC Rog1ing Division to do the work as specified herein and any additional work requested.
I HAVE READ AND AGREE TO THE NOTICE ON THE REVERSE SIDE
DocuSigned by:
Owner or Authorized Agent --• t' 8/26/2017
Date:
Print Name Joel Kell EB32247355484F&..
Precision Homes Authorized .Agent
*In accordance to C ado's Senate Bill 38, the following in required by law Date: be print4on iscontract.
1) Precision Homes shall hold in trust any payment received from you until Precision Homes has delivered roofing materials at the site or has performed a majority of
the roofing work on your property. 2) Precision Homes carries workers' compensation, automobile and commercial general liability (bodily injury and property dam-
age) insurance. A Certificate of Insurance identifying our insurance carrier and the types and amounts of coverage and our insurance contact information shall be
provided upon request. 3) You, the buyer, may cancel this contract at any time prior to midnight on the third business day after the date that you signed this contract
unless services have already been provided and/or negotiations have begun. 4) Precision Homes or any other party is prohibited for stating or implying in any way to
pay, waive or rebate the homeowner's insurance deductible in part or whole.
(303) 993-6057 1900 Federal Blvd, Denver, CO 80204
PrecislonHomesofColorado. cOm
DoUbSign Envelope ID: E1259139-1656-4639-AB39-90DEF83D97B5
Right of First Refusal
Owner grants Precision Homes, LLCRoofing Division an exclusive right to perform work and repair on any final estimate generated by the insur-
ance company(ies).
Cash Bids
All cash bids are valid for thirty (30) days due to quarterly fluctuations in material and or labor costs. Payment terms for "cash bid" jobs require
(50%) due before materials are delivered; remaining balance shall be immediately due and payable upon completion of the specified work.
Agent
Owner acknowledges that Precision Homes, LLC Roofing Division is appointed as Owner's agent and representative in working on their behalf to
assist in Owner's insurance claim negotiation. Owner agrees to cooperate with Precision Homes, LLC Roofing Division in this regard and shall
share any and all documents or correspondence received to Owner's insurance claim with Precision Homes, LLC Roofing Division Owner ap-
points Precision Homes, LLC Roofing Division and it's authorized representatives as it's attorney-in-fact to take any action necessary to effectu-
ate the terms of this contract.
Material Selection
Owner is solely responsible for the material and color selection of all products utilized by Precision Honies, LLC" Roofing Division and agrees to
insure that all selections shall meet or exceed any neighborhood, city, homeowners association, zoning, master lease, building code or any other
requirements. Owner shall indemnify, defend and hold Precision Llomes, LLC Roofing Division harmless from any action brought by any person,
group or entity concerning the quality, type, color or other characteristic of the material selected by the owner.
Acknowledgment of Work by Owner
Owner acknowledges that Precision Homes, LLC Roofing Division shall not be responsible for minor inconveniences and damages resulting from
Precision Haines, LLC Roofing Division work at the contract property in accordance with all generally accepted industry standards and practices
generally associated with this type of work.
Failure to Perform
Owner acknowledges that Precision Homes, LLC Roofing Division will not be responsible for any failure to perform it's obligation due to labor
controversies, strikes, acts of nature, material shortages, labor shortages, eminent domain actions, court or any other government agency or authori-
ty declarations, or any other circumstances beyond the control of Precision Homes, LLC Roofing Division
Additional Work
Costs for the replacement or repair of any roofing system components (including, but not limited to decking, fascia, swamp coolers, solar panels,
vents, exhaust, HVAC components, chimney or chimney flashing, step or headwall flashing, windows, etc.) or additional work not specifically
stated in this contract are not included. In addition, any work or damage uncovered during the repair or replacement process that was unforeseen is
not included in this contract. Such work will be billed separately as an extra and billed according to the fair market prices. Precision Homes, LLC
Roofing Division agrees not to make any changes in the schedule of work, design, or of the specifications without written authorization by the
Owner.
Access
Customer will provide required access to their property during daylight hours in order for Precision (fomes, LLC Roofing Division to perform the
work stated in this contract. Customer hereby agrees to pay a reasonable charge if access is either denied or unobtainable and arrangements have
not been previously made.
Limited Warranty
Precision Homes, LLC Roofing Division shall provide a limited warranty against leaks on total roof installations performed by Precision Homes,
LLC Roofing Division should such leaks result be a result of Precision Homes, LLC Roofing Division faulty installation. Such warranty does not
extend to leaks or water damage below the roof line or any damage resulting from lightning, snow, excessive wind, ice or hail during the warranty.
Owner hereby acknowledges that no other warranties, expressed or implied.
Permits and Codes
Precision Homes, LLC Roofing Division shall obtain all necessary building permits, and will comply with all building and code regulations and
ordinances whether or not covered by the specifications and drawings for the work.
Work Performance
Precision Homes, LLC Roofing Division shall perform all specified work in substantial compliance with all generally accepted industry standards
and agrees to keep the premises clean and orderly and will remove all debris.
Accounts
Accounts are past due if full payment is not received ten(10) days after work is substantially completed. In the event that the insurance company
has issued payment to anyone in connection with repair or replacement of the property, then full payment for any work performed is due. If the
customer then does not use Precision Homes, LLC Roofing Division then a 20% charge is immediately due and payable by owner to Precision
Homes, LLC Roofing Division The amount due is for time spent preparing, measuring, getting material, allocating resources by Precision Homes,
LLC Roofing Division and the parties agree 20% is reasonable estimate of loss. Customer acknowledges that Customer shall be responsible for all
costs of collection of any amounts due including, but not limited to, attorney's fees, expenses, costs and expert witness fees. All amounts past due
for more than 30 days will accrue interest at the rate of twenty-one percent (211/6) per annum.
Dispute Resolution
The parties agree that the provisions of the Colorado Construction Defect Action Reform Act, at C.R.S. 13-20-801, et. Seq. shall apply to any dis-
pute arising from this contract.
Cancellation
If this contract is cancelled by the Customer after the third business day and prior to the commencement of work, Customer shall pay the Precision
Homes, LLC Roofing Division (20%) of the contract price or as determined by the insurance loss sheet replacement cost value, for services. Preci-
sion .Homes, LLC Roofing Division agrees to accept (20%) as reasonable and just compensation for said cancellation. If this contract is cancelled
by the Customer after commencement of work, customer will pay in addition for materials, labor and associated profit for work completed up to
and including the date cancellation is received in writing by Precision Homes, LLC Roofing Division. Payment should be made to Precision
Homes, LLC Roofing Division and delivered or mailed to the address listed on the front of this contract.
This Contract shall be construed under the laws of the State of Colorado and may be modified or amended only by a written instrument executed by
both the Owner and the Contractor
(303) 993-6057®o 1900 Federal Blvd, Denver, CO 80204 ®® PrecisionHomesofColorado.com
k
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office' * (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type
Job Address 5A?!
Permit Number
❑ No one available for inspection: Time A 7_4
Re- Inspection required: Ye No /
*When corrections have been made, call for re- inspection at 303 - 2345933 '
Date:
/�,��` , Inspector: %
DO NOT REMOVE THIS NOTICE '`
I
f,
�' ♦ i CITY OF WHEAT RIDGE
4 Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 237 -8929 Fax
` INSPECTION NOTICE
p Inspection Type: Fin,%3 -L ��t=
Job Address: _ Y;Z Sa 13ALsa -.*7 5-r
Permit Number: �Vk97X3
❑ No one available for inspection: Time 11 a PM
Re- Inspection required: � No
'
When corrections have been made, call for re-inspection at 303-234-5933
Dater t'71 Inspector: �, c
DO NOT REMOVE THIS NOTICE
♦ i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234 -5933 Inspection line
(303) 235 -2855 Office • (303) 237 -8929 Fax
INSPECTION NOTICE
Inspection Type: _ti�✓.�� A�l
Job Address: Y.2 So 13�1�59 ,r si
Permit Number: 09,
4t7!?£C? 1raa irvSAFc�Ti ®. 5t4 1;27:
Cre xry rf�ct1 LFS�,u 'rnr ;3lce ilo ctl
K1N • tf .rJu� A.��',n2
7 v.�',?i'7 ',�r�sf�t`�cT,e
❑ No one available for inspection: Time AMA MD
Re- Inspection required: es . No
When corrections have been made, ca0 for re inspection at 303 - 234 - 5933
Date: 9 ,115 /1 Inspector:
r
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge Building Division
7500 W. 29th Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-235-2857
o Inspection Line: 303-234-5933
OCORPO
Building Permit Application
Property Address:, Lf r) -i~ IA 1 ` rD M
Property Owner (please print):
Mailing Address: (if different than property address)
Address:
Date:66~ Uq
Plan
Permit
Phone:
s66G
City, State, Zip:
Contractor: '8 L,11K-& R()C)6 N9 <<~ O(5Iv,SI VZCJ,--C.tT16 N
Contractor License Phone: 3 L , 43'x- :3 0 b
Sub` Contractors:
Electrical City License
Company:
Plumbing City License Mechanical City License
Company Company:
Exp. Date: Exp. Date: Exp. Date:
Approval: { Approval: Approval:
Use of space (description): C n S Construction Value: $ ~o ,5 0
YG ~-to d~.'F vet (as calculated per the Building luation Data shoot)
Descriptiomof'.work:
L~ t~~ L--to 3 O ~ 6L11M 0 Plan Review (due at time of submittal): $
36 " [-~larz k
Sq. Ft./L.Ft added: Squares 30 BTU's Gallons Amps
OWNERICONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances,
rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and
allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full
responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work
under this permit. Plans subject to fiel inspection.
CIRLCE ONE:: (OWNER) (CONTRACTOR) or PERSONAL REPRESENTATIVE of (OWNER) (CONTRATOR)
PRINT NAME: 'L-^ SIGNATURE: Cut-C3.4-,- Date: 6, ~-3 6
~
O
3
0
z
O
m
a
a
3�
Y
i
S
m
a
3
N
9
m
n
z
O Z
n 0
n o
c �
a v
a J
J �p
� N
O �
S 1�0
m 3
O m
d a
o �.
� m
c
N� N
:D �
m
v
c
CL
0
a
0
J
J
n
N
n
a
m
m
0
n r
M
n
O
M
O
M
z
_
M O
D
O
o
A
O
A
rD
O
o
a
M
z
w
o
a
z
n
W
N
A
.
p
O
M
n
1
CB -i
°1 n
c�
�6
mn�
rto"
N N
6
O rt
on
CD rt
Mau (D
n'=
o
a
vmN
Q- n
maw
min
a n a
non
�3o
aim
n N
� 3D
D [D
m =O n N O
O rt N
n
�*Ao
M O ,
m iv r.
C [D3
O C 6
in- C
a n-
��n
n �
N n�
n o v
n
m
N O
O
C�
� C
N �
� N
n
O `
rt C
M a
M
m �
� rt
rt 3
a N
ad
6
O O
n0
3
z
6
m
0
a,
rn
N
A ° oO
� � C
� N G
o ^=
<D
(D
o c �
W ry
O �
D
r1
(D
N
W
Cf
N
O
0
O
1
y
I�
F�1
O
O
1
u �
V
z �
l 1
Date
A Certificate of Occupancy or Completion has been requested for:
ADDRESS: 12= &, YL
Purpose of Structure:
Building Department Approval: &jK—
Remarks:
Zoning Approval:
Remarks: �`—
Public Works Approval:
Remarks:
Fire Marshall Approval:
(If Applicable)
Remarks:
Sanitation District Approval;
(If Applicable)
Remarks:
Water District Approval;
(If Applicable)
Remarks:
DEPARTMENT OF PLANNING AND DEVELOPMENT
BUILDING INSPECTION LINE - 303 -234 -5933
CITY OF WHEAT RIDGE
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215 - (303- 235 -2855)
Building Permit Number
Date
10662
Property Owner:
Property Address: 4250 BALSAM STREET
Contractor License No.: 17729
Company : Budget Garages & Construction, Inc.
Phone: 423 -3923
Phone: 7571800
OWNER /CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate; that I have read and agree to abide by all conditions printed on this
application, and that I assume full resp lity for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicabl Wh Ridge ordinances, for work under this permit.
(OWNER)(CONTRACTOR) SIGNED Mme - 9^— DATE I
Description : Detached garage
Construction Value:
$9,000.00
Permit Fee :
$167.25
Plan Review Fee:
$0.00
Use Tax:
$135.00
Total:
$302.25
Use:
BUILDING DEPARTMENT USE ONLY
SIC : Sq. Ft.
Approval: MLC Complies with R -2 regs.
Zoning: R -2 P 101111111 8 Mi
Owna lcmhndor is responsible for locating property
6 -12 -00
lines and constructing improvements according to the
Approval: BG approved plan and required development standards.
The City is not resporisible
z inaccurate in.`ornatior,
1 x�xs: " S r ;'Iii d R ' I':I2 %l:e Plan S et ari ..71y. CCi75 ��,i.,:
Approval : u= sd ng from inaec , ,,,gorr, a,tur.
Occupancy: Walls: Roof : Stories : Residential Units :
Electrical License No :
Company:
Expiration Date
Approval:
Plumbing License No:
Company:
Expiration Date
Approval :
Mechanical License No:
Company:
Expiration Date
Approval :
(1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning
Regulations and Building Code of wheat Ridge, Colorado or any other applicable ordinances of the City.
(2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 days.
(3) If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
(4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
(5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proceeding with successive phases of the job.
(6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of the building codes or any other ordinance, law, rule or regulation.
J
C ej uil &I rd ldi
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number:
BUILDING INSPECTION DIVISION - 235 -2855
CITY OF WHEAT RIDGE Date
7500 WEST 29TH AVENUE
WHEAT M
IDLE CO 80215 APP IICATio N
PropertyOwner:��. � u�
Property Address : Li Phone : 3
Contractor License No.:
Company
OWNER /CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate,
and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or
covenants, easements or restrictions of record; that all measurements shown, and allegations
made are accurate: that I have read and agree to abide by all conditions printed on this
application, and that I assume full responsibility for compliance with the Wheat Ridge Building
Code (U.B.C.) and all other applicable Wheat Ridge ordinances, for work under this permit.
(OWNER)(CONTRACTOR)SIGNED F-1 ll 1 ��_ OATE 11 •o�
Description
QD��
otn . omm, �_
Approval:
Zoning
w n om
Approval : ea 647/0 el
Approval:
Occupancy: Walls :
Electrical License No:
Company :
Expiration Date
Approval:
Construction Value: �J U
Permit Fee
Use Tax UO '-
Total
Use:
)tPARTMENT USE ONLY
Roof : Stories :
Plumbing License No:
Company :
Expiration Date
Approval:
SIC
rr``
I V G®
66
Mechanical License No
Company:
Expiration Date
Approval:
5
(1) This permit was usuetl with the Provisions set to
g aemrtlarce ll in yopur aPPlifation and is subject to the am of the State of Colorado and fo m .'.onmg
Regulations and Building t:Ode of l WdW Ritlge. lAbredP or arty other aPPlicaple ortfinanw at the City. (2) abandoned fo as pe exir A (A) d wont aNhor¢ed is not commenced within silly (60) days from issue date or (8) the building authorized is suspended or
Wad of 120 days.
(d) anginP
l plans r and t be a tired for a lee of one-half the amount normally required, Provided no changes have been or will be nude in site am (1) year. Ng fees shall be paid forpn� Wp rrnd w m has not exdeeded one (1) year. If changes are made w 9 suspension w abantlonment
(4) No work of any manner shall be done mat will Change the natural
(6) C
flow of water raising a drainage problem.
P roceetliin wth sl�sy
i eptik Ins pector f t) MH'fo� (24) hours in advance for all inspections and shall receive written approval on inspector, card before
(6) o ff s issuance of a permit or the approval o�tlrnnngs and speCficatians shall not be mnsWetl to Dc a pemtit for, nor an approval of. any violation of fox provisions
the building Codes ar any oth oreinartce, aw, rya or legylatian.
Chief Building Inspector
Phone :3a ,
0" "60& c alas
& Construction
Co. Inc.
Earl A. Ritter
President
t A
Minimum
Provide solid 2x blocking
between rafters or trusses
t/ M
NMdavac
board
Note: Pre-engineered roof trusses
wAnus clips and hardened naiis may be
used in lieu of roof structure shown.
Diagonal wind bracing or plywood ehoar panels
0 comers and each 25' of wall
{
ya s� B.a.�sra,r1 ST.
e e) �UU33
(•at•IW�'4 Yaeor pl 1 1
Roof coverin 3— TiAL3
7 pxanaw cI.ss A7 wo+N)yrus)
Underlayment /S
pitch
2x,L�ceiling joists @ O.C.
Double 2x le "top plate
(example: 2 r 4)
Span 7 -!� — ,�
(examae
Ceiling height 1,o ,
)eumpe: 4)
Sidin
(•+rrr'ae: 4p Of F I I I)
0 �. B
Detail A
DOWI 13
I
0111 cabL cvatw nvcnuc • ucnvcr, wwraaU ouauc
Wall sheathin *
2x V studs @A/, O.C.
(0 -:ple: 2 x + O .
,, P f rfd
Cont. 2x�ssl�pJate
la+anpe: 2 x +)
Footing size _
'I i.-P. 7- i�7
Id OU0J A 64QYc' 7 $Wppd dtlons
Wheat Ridge Building Dept, /
Bate. -61 M{ (�
� .... Plan Chr V6r
Budget Garages
&Construction
"` • - • - ---Co. Inc.
P iw
r P�p
r
'fo PO eqs• r /,o v
ya s0 sr.
Show door and window header 61206 and IocoOW
and on of landing in front of door
r
Si
C 3 1 wininimumcomets slab
y .r
Header size x__-
�.0 Na.INR ny2r 10
'v /L �
Duo 2 Note:
toot trusses or ratwra Lear on header, Special
f/fpo f hda
earde"i gn may be required'
Double 2x4 or 2x6 tdmmom each
end of overhead door header
/ L Ga age door opening width a
Lap siding over foundation a
minimum of 1
Overall length
'Yam diameter steel anchor bolts 6'-0' O.C.
max., T min. penetration max. 12' from
comer and 12' from each end of plate.
Bottom plate shall be treated
wood or Foundation redwood
3'h' Minimum Concrete Slab
0
Finished
Note: Check with local building
department for swelling soils.
i Caissons may be mgtared.
t
s
6' min. 1•
H
18' min.`� . • Y4teb4r mm cont ,top SFbonors w c E D
3 .
n��"s•
W
� 2(
r
U
W
I� -mCd
H
4T
d
N
------ 42.0'
U�
a
0
R
LLI
5,6 UTIL,
L LJ
a
g �
V
o
IL
J
W
�
m w
0
F
a
LU
0
+
H1Z
l�
I — I .Q
w
W
N
r u
/ C
\ G w
<30
m(3i �--
C)
N z
0
c(�
a
J
0
°II
5.0 1.V T, U.
� 2(
r
I� -mCd
4T
d
N
------ 42.0'
--3
5,6 UTIL,
CSM•
InII
w
h
a
h
ESM'T
F-
w
Ij Q
III
L
N
cq
° CO sue_, oo N --�
rn a�i 60 ¢ j. z c/1
X v n
°w z
n U°
W vv u w
W OA N
a cv v Qcoq
m d H e °: ac o cu o z• °�a d
I'0 v . mo w
cc
X 2 n 7
o E
y C
cn
v u y O C>1
W d d d O
d 7 O w 'C P. s. N V S, L LI
1,14 0 1`] Q w V C \
CD
C
w o - E C v [
y= o Z m 4
O C
QQ a+ "0/7 Q Ong 3
cd
V
V
0�Z a 0 � v Ow ,C) s s
V
w �y iu °O�•a p.oxA O O ��
a� v O IS S wa go
O p 5
S 3 m
0 0 W
a D �
z a Q
5
3
N 3
r! N
m a
n
Oz
O O
O O
c �
d N
T N
o d
3 =
� m
O d
N
o
c
m
N �
N
c
O
a
0
0
m
m
m
0
m
O
A
m
O
O
z
n
C
A
O
m
m
O
n
C
B
N
7
m
D
v
m
n
v
a
v
O
v
m
D
v
v
m
N
w
Z
a
(D
z
- o
CD
Q.
N
N
tt
� � z
d3° c
O � 6
<3�
N 6 r�r
o � m
mn� o
0
O O N Ol
N
0 3
� O pi
O a �
3 < D
M au
n N c
0 M
°cry
*an
Cr
n o rt
n 0
al <
m0a Pf
N p W
a 0 Q
� P V
3 O A O O
3 a ° a In
SD
v Y
6 N n w
o3 m
c 3 a Q O M
m �G'Oa ° ro c 70
Q30 O �
0 m
' d N
O �+ Q m m
3Q�
c tD3
� C 6
0 a C
�
° nom
0n
N O v
j D D
� m
d
n N
O'
0 a N
(D n 0]
z N
n N
y O
UO O
av o
E7 6
O O
Q N
r
H
FBI
H
O
^ O
1
y �
V
z
W
co _I.-
Cl)
ZZ
:) o'
o�
W
m F-
Z O
J_ H
�
cn a
Z Cl)
0-
oc
a v
Z = cn —,
F-
M Q
z
'^ U) a
N U
Z °
O C'7 U
N
W o
0 0 �.
M w
V O w LL
Ct) I L C/3
z o
D 0 � o
W
W F a
W 'R O
� v � C
v � w
i=- R z 1
r
O W 1
Z Qa W _
cn
cc
W N
U
O TwwmJJJ W c
ca Z ]17 W d o
LJ.1 � o E ✓ s w
N n �..->, z C, o .o
,
w V ¢ O
w W Q LL N C C
Co ¢
p 0 Z C: c U C "' N C ro
ma W Z U U LL 3: -
o m
m O O
c
6
O
C
0
ro
N
w
O
C
0
a
Y
0
m
C
- t
s
��
(D
w
L
m
x °
2
a
C
m
cr
m �
Q
N
;
d
i
'a
ro
C
aS
m
a
x
L
m
¢°
�I
�I
r
\
n
n
Q
m
c
°
c
=
0
m
O
cm
•C
O
ro
v
7
cca)�
Q
od
CL
J
ro
N
O)
0
a)
ru
N
cc;
N
C
7
ro
N
O
N
v
LL
=
Q
x
LL
W
W
d
x
LL
x
Il
d
DEPARTMENT OF PLANNING AND DEVELOPMENT Building Permit Number:
10662
BUILDING INSPECTION DIVISION - 235 -2855
CITY OF WHEAT RIDGE
Date:
6/13/2000
7500 WEST 29TH AVENUE
WHEAT RIDGE, CO 80215
Property Owner:
Property Address: 4250 BALSAM STREET
Phone : 423 -3923
Contractor License No.: 17729
Company: Budget Garages & Construction, Inc.
Phone: 757 1800
OWNER /CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
Construction Value :
$9,000.00
1 hereby certify that the setback distances pro osed by this permit application are accurate,
permit Fee :
$167.25
and do not violate applicable ordinances, ru s r regulations o e City f Wheat Ridge or
covenants, easements or restrictions of re ord t t all meas a ents s own, and allegations
Plan Review Fee :
$0.00
made are accurate; that I have read and gre t abide by this
application, and that I assume full respc ib/II or compll cge Building
Use Tax :
$135.00
lition
Code (U.B.C.) and all other applicable eat ge ordin ncs permit.
Total :
$302.25
(OWNER)(CONTRACTOR) S IGNED `�
Use:
Description : Detached garage
BUILDING DEPARTMENT USE ONLY
SIC
Approval: MLC
Zoning: R -2
Approval: BG
Complies with R -2 regs.
6 -12 -00
Approval :
Occupancy:
Walls : Roof
Sq. Ft. :
Stories : Residential Units :
Electrical License No: 18362 Plumbing License No : Mechanical "License No:
Company: Creative Wiring Company: Company:
Expiration Date : 7/6/2001
Approval: OK/KS Expiration Date : Expiration Date:
Approval: Approval :
(1) This permit was issued in accordance with the provisions set forth in yopur application and is subject to the laws of the State of Colorado and to the Zoning
Regulations and Building Code of wheat Ridge, Colorado or any other applicable ordinances of the City.
(2) This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or
abandoned for a period of 120 days.
(3) If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the
original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes are made or if suspension or abandonment
exceeds one (1) year, full fees shall be paid for a new permit.
(4) No work of any manner shall be done that will change the natural flow of water causing a drainage problem.
(5) Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before
proosediing with successive phases of the job.
(6) The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions
of the b " g codes or other ordinance, law, rule or regulation.
C uilding I ector For Mayor
THIS PERMIT VALID ONLY WHEN SIGNED BY THE CHIEF BUILDING INSPECTOR AND MAYOR
CALL: 234 -5933 24 HOURS PRIOR TO INSPECTION