Loading...
HomeMy WebLinkAbout3691 Garland StreetFrom: no-reolv(alci.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Furnace/Boiler Replacement Permit Application Date: Wednesday, September 22, 2021 12:49:45 PM Furnace/Boiler Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT FURNACE or BOILER - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes replacement residential furnace or boiler like for like? PROPERTY INFORMATION Is this Residential or Residential Commercial? Property Address 3691 Garland St. Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Ron Osterhaus 303-585-0791 ronaldosterhaus@comcast.net CONTRACTOR INFORMATION Contractor Business Now Heating & Air application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Lindy Johnson Permit Email not displaying correctly? View it in your browser. Name Contractor's License 022414 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 303-288-2299 Number (enter WITH dashes, eg 303-123- 4567) Contractor Email installs@nowha.com Address Retype Contractor installs@nowha.com Email Address DESCRIPTION OF WORK What type of unit is Furnace being installed? Number of BTUs 70000 What is the efficiency 80 (%) of the unit? Is the unit GAS or gas ELECTRIC? Where is the furnace or basement boiler located (for example, basement, crawlspace, etc)? Project Value (contract 5200 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this INSPECTION RECORD INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection INSPECTION REQUEST LINE: (303) 234-5933 Occtivangy/Type fl Zf Inspections will not be performed unless this card is posted on the project site. **Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Date Inspector CommentsInitials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior To Approval Of The Above Ins Underground/Slab Inspections Date Inspector CommentsInitials Electrical Sewer Service Plumbing nn Nnf rnvPr Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections Rough Inspections Date Inspector CommentsInitials Wall Sheathing Mid -Roof Lath / Wall Tie Rough Electric Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading _ Insulation Drywall Screw/ Nail Final Inspections Inspector Date Initials Comments Landscaping & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW & Drainage / Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof i Final Window/Doors Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of r)rr, manr l is icci,arl Annmval of the Final Bui/dina inspection does not constitute authorization of occupancy. *For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather City of Wheat Ridge ---106 Residential Roofing PERMIT - 201703588 PERMIT NO: 201703588 ISSUED: 07/10/2017 JOB ADDRESS: 3691 Garland ST EXPIRES: 07/10/2018 JO13 DESCRIPTION: Residential Re -roof to install asphalt shingles - 29 sq. *** CONTACTS *** OWNER (303)883-4691 OSTERHAUS RONALD L SUB (303)756-7663 Ty Correy 090134 Advanced Exteriors, Inc. **' PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / ** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,.000.00 FEES Total Valuation 0.00 Use Tax 273.00 Permit Fee 251.85 "* TOTAL ** 524.85 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior, to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to he fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water_ shield is required. Eave and rake metal is required. A ladder extending 3 feet above the rcof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply wiLh arplicable codes'and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material. brand name) roof covering" is required to be on site at the time of final inspection. Ro:)f inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 40'2�'L4:�44 b Permit Number: `2-0 `-1 D'25 5 tYa ❑ No one available for inspection: Timeo5s_b6dPM Re -Inspection required: Yes No When corrections have been made, call f9r e -inspection at 303-234-5933 Date: 2 Inspector: '4n 1z, DO NOT REMOVE THIS NOTICE City of Wheat Ridge ®� Residential Roofing PERMIT - 201703937 PERMIT NO: 201703937 ISSUED: 07/13/2017 JOB ADDRESS: 3691 Garland ST EXPIRES: 07/13/2018 JOB DESCRIPTION: Residential Re -roof to install GAF/Timb HD asphalt shingles - 29 sq *** CONTACTS *** OWNER (303)883-4191 OSTERHAUS RONALD L SUB (303)756-7663 Ty Correy 090134 Advanced Exteriors, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,000.00 FEES Total Valuation 0.00 Use Tax 273.00 Permit Fee 251.85 ** TOTAL ** 524.85 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. t li i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: —YJ�� Md Job Address: f Permit Number: ❑ No one available for inspection: Time j.. AM/PM Re -Inspection required: Yest'. No -- *When corrections have been made, call for re -inspection at 303-234-5933 i Date: �o• ��'/ Inspector: Jny! C7)/ ' �- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE 1 Building Inspection Division / (303) 234-5933 Inspection line VV (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:G /� Job Address: 3 Permit Number: / ❑ No one available for inspection: Time "I­AMV pm ) Re -Inspection require Yes o 5 When corrections have been made, call for re -inspection at 303 -234 - Date: Inspector: ) CAja� lk"'K - DO NOT REMOVE THIS NOTICE City of Wheat Ridge rt jg_ Residential Roofing PERMIT - 201703588 PERMIT NO: 201703588 ISSUED: 07/10/2017 JOB ADDRESS: 3691 Garland ST EXPIRES: 07/10/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 29 sq. *** CONTACTS *** OWNER (303)883-4691 OSTERHAUS RONALD L SUB (303)756-7663 Ty Correy 090134 Advanced Exteriors, Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2406 / BEL AIRE,HILLCREST HEIGHTS, ME BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,000.00 FEES Total Valuation 0.00 Use Tax 273.00 Permit Fee 251.85-�--'- ** TOTAL ** 524.85 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd party inspection report will be collected at final roof inspection performed by City of Wheat Ridge. If report is not available the final inspection will not be completed. City of Wheat Ridge Residential Roofing PERMIT - 201703588 PERMIT NO: 201703588 ISSUED: 07/10/2017 JOB ADDRESS: 3691 Garland ST EXPIRES: 07/10/2018 JOB DESCRIPTION: Residential Re -roof to install asphalt shingles - 29 sq. 1, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as partes to the work to be performed and that all work to be perf0 1ed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER ,, CONTRACTOR (Circle one) Date ` I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow -of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for or an approval of, any violation of any provision of any applicgblde or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. N Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest@ci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Dane Lovett -zo 1 10 � 5-? b From: no-reply@ci.wheatridge.co.us Sent: Tuesday, June 27, 2017 1:29 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Categories: Dane Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number 3691 garland st ron osterhaus 303-883-4691 I- stip i vs Property Owner Email Field not completed. Address Do you have a signed Yes contract to reroof this property? It will need to be provided at the time of permit pick-up. CONTRACTOR INFORMATION Contractor Name advanced exteriors Contractor's License 090134 Number (for the City of Wheat Ridge) Contractor Phone 303-725-4502 Number Contractor Email Address freddygreen@advancedexteriors.net Retype Contractor Email freddygreen@advancedexteriors.net Address DESCRIPTION OF WORK Are you re-decking the No roof? Description of Roofing asphalt Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 29 material selected above? Does any portion of the No property include a flat roof? If yes, how many squares Field not completed. on the flat roof? 2 TOTAL SQUARES of all roofing material for this proj ect Provide additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) 29 reroof 29sq with timb hd, 130, lifetime, 4/12 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant freddy green Email not displaying correctly? View it in your browser. 3 6 Advanced Exteriors, Inc. Property Owner(s) Customer 0Proposal Date 7 Prop" Address t S Primary Phone . City, State zip V secondary Phone In Company Claim # 277 1'7060-7 Eail A mddress Tear *off IQVeqs)ofcomposffion& layer(s) of g-4oz- 5471 Standard ridge High profile ridge Inspect decking Q Install decking Install ice Install ridge vent Lo -- ci,-- c 0 and water shield on Install 15 # felt El Install Install turtle vents 17 install .sC t— Vents 30 #felt Install Install pipe Jack flashings Elinstall furnace caps premium synthetic deck protection install starter Point jacks/stacks to match reefing cplor course of shingles -entire perimeter 9 Detach and reset S Install drip edge perimeter flashing - color S Remove and cover ti (of install reinforcement in valleys using Install beauty course of ridge shingles on headwalls Closed valleys Open valleys Replace Detach and reset satellite Remove satellite step flashirig on sidewalls, chimney and skylights Install 6 Clear) up & remove trash Sweep with magnetic roller nails per shingle throughout field area Roofing Cv- A r- Clean out gutters Provide building permit product -Sr Roofing - S I -z,-c Register Manufacturer Warranty color -, Manufacturer Warranty e- Advance Exteriors, Inc, Five Year Roofing Labor Warranty Advanced Exteriors, Inc. S2.000.000 Linhility Inm ir(-in(-,- Special Insfructions/AdditionalWork 7 a— L( Approximate Date(s) of Payment T insurance Mum, Fla 'Work completed In accordance with these specifications forthe price of; $ 1 Dollars The property owner(s) (`°Customer") authorizes Advanced Exteriors, Inc. ("Company,,) to work with their insurance, carrier to obtain the PLWO q of repairs necessary for restoration of storm damage, This "Agreement' is not binding upon Customer or Company unfil the insurance comer approvesCustomer's claim and this amount is accepted by Company, Upon acceptance by Company, the amount approved by the insurance carrier will become the final contact price and Company will receive the insurance proceeds for VDJ*jLbcls��,G�t. The Company will complete specified watforn 2.9�� to Customer beyond the agreed claim amount except for the Insurance cle-ducf1ble, Customer is / is not [:] intending to make payment from the proceeds of a property and casualty insurance policy, If Customers payment Is from an insurance claim, then pursuant to Colorado law Company I' roofing contractor) "shod not advertise or promise to pay, waive, or rebate all or port of any insurance deductible applicable to the claim for payment for roofing work on the covered residential property," CRS, § 6-22-105, The Company shall hold in trust any payment receked from Customer until Company has delivered the t(-->ofIng materials to Cusloi-ners property or when Company has performed a majority of the roofing work on Customers property 1, !1 111 - - 0 1 1 0 * 8 0 4 11�11111�1111111 111111111111 0 Acceptance Date INSPECTION RECORD Occupancv/Tvpe INSPECTION LINE: (303) 234 -5933 Inspections will not be made unless this card is posted on the building site Call by 3:00 PM to receive inspection the following business day. i Mr M _ INSPECTOR MUST SIGN ALL SPACES PERTAINING TO THIS JOB FOUNDATION INSPECTIONS DATE INSPECTOR INITIALS COMMENTS: Footings /Caissons Drywall Screw Stemwall / (CEG) Concrete Encased Ground Reinforcing or Monolithic Weatherproof / French Drain Sewer Service Lines Roof" Water Service Lines POUR NO CONCRETE UNTIL ABOVE HAS BEEN SIGNED CONCRETE SLAB FLOOR - Electrical (Underground) Plumbing (Underground) Heating (Underground) DO NO POUR FLOOR UNTIL ABOVE HAS BEEN SIGNED ROUGHS Lath / Wall tie Mid -Roof Electrical Service Rough Electric Rough Plumbing Gas Piping Rough Mechanical Framing Insulation Drywall Screw Roof" R.O.W & Drainage INSPECTIONS FOR PLANNING & ZONING, FIRE AND PUBLICE WORKS Parking & Landscaping SHOULD BE CALLED AT LEAST ONE WEEK PRIOR TO FINAL INSPECTIONS. "NOTE. ALL ITEMS MUST BE COMPLETED AND APPROVED BY PLANNING AND ZONING, BUILDING AND PUBLIC WORKS BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED. FINAL INSPECTION BY THE BUILDING DIVISION DOES NOT CONSTITUTE AUTHORIZATION OF A CERTIFICATE OF OCCUPANCY NOR PERMISSION FOR OCCUPANCY. OCCUPANCY NOT PERMITTED UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED' PROTECT THIS CARD FROM THE WEATHER DEVELOPMENT DEPT. � Inspection Services Division (303) 234 -5933 Inspection line / � ' + � /� pp ( 3 303) 235 -2855 Office EJ Elec. ❑ Plumb. ❑ Mech. ❑ Structural Other p 1st ❑ 2nd ❑ 3rd Job Address: ❑ Re- inspection fee of $ must be paid prior to re- inspection. ❑ Blocked Access ❑ No one available for inspection: Time 7M AM' M *When corrections have been made, call for re-inspection at 303 - 2345933 Date: M ij Inspector: LI1�9P' DO NOT REMOVE THIS NOTICE f ,",ITY OF WHEAT RIDGE ilding Inspection Division ❑ No one available for inspection: Re- Inspection required: l' No *When corrections have been made, call for r - inspection at 303 - 234 -5933 Date: ����® Inspector; e- A' - DO NOT REMOVE THIS NOTICE r ............... ♦ i CITY OF WHEAT RIDGE Building Inspection Division r4000 (303) 234 -5933 Inspection line (303) 235 -2855 Mice - ( 303) 237 -8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM /PM Re- inspection required: Ye,) No ' When corre tions have been made, call for re- inspection at 303 -234 -5933 Date: I Inspector-, DO NOT REMOVE MS NOTICE e" + City of Wheat Ridge 0 ]r Residential Roofing PERMIT - 102085 PERMIT NO: 102085 ISSUED: 09/01/2010 JOB ADDRESS: 3691 GARLAND ST EXPIRES: 09/01/2011 DESCRIPTION: Reroof 26 sqs with 30 yr Timberline GAF /ELK shingles * ** CONTACTS * ** owner 303/422 -0208 Ron Osterhaus sub 303/762 -0089 Heyward C. Oliver 01 -9720 Five Sons Roofing ** PARCEL INFO ** ZONE CODE: UA USE: UA SUBDIVISION: 0624 BLOCK /LOT #: 0/ ** FEE SUMMARY ** ESTIMATED PROJECT VALUATION: 16,103.20 FEES Permit Fee - 315.25 Total Valuation .00 Use Tax 289.86 ** TOTAL ** 605.11 Conditions: 6 nails per shingle,is required. Ice dam membrane is required from eave edge to 2' inside exterior walls. Board sheathing with any gap greater than 1/2" requires panel sheathing overlay on entire roof. Sheathing inspection is required prior to covering. Midroof inspection is not required on permits purchased after 4/18/10. Contractor shall provide ladder for inspections. Scheduled inspections that cannot be performed due to inclement weather must be cancelled prior to 8:30 a.m. on the day of inspection or a re- inspection fee will be assessed. I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicab Whgat dge Ordinances, for work under this permit. Plans subject to field inspection. Signature of contractor /owner 1 1 date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire 180 days from the issue date. Requests for an extension must be received prior to expiration date. An extension may be granted at the discretion of the Building Official. 3. If this permit expires, a new permit may be acquired for a fee of one -half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. I. Contractor shall notify the Building Inspector twenty -four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review ha subject to field inspections. Signature ff - CFiW Building Official date INSPEC,IqON REQUEST LINE: (303)234 -5933 BUILDING OFFICE: (303)235 -2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. oF" " City of Wheat Ridge Building Division 7500 W. 29" Ave., Wheat Ridge, CO 80033 Office: 303 - 235 -2855 * Fax: 303 - 237 -8929 °otoRto° Inspection Line: 303 - 234 -5933 Building Permit Application Property Address (o CA Q,( S T Date: Plan #: Permit #: (09- 63c), Property Owner (p /ease print): OS7 0s yaz- 0208 Mailing Address: (if different than property address) Address: City, State, Zip: Contractor: Contractor License #: Sub Contractors: Electrical City License #: Company: 1 r.J Phone: Plumbing City License #: Company Mechanical City License #: Company: Exp. Date: Exp. Date: Exp. Date: Approval: Approval: Approval: Use of space (description): Construction Value: $ /in. lC13.2l� Description of work: A r-m dilc K t STy,.I (as calculated per the Building valuation Data sheet) / -.- kqof) F /^IS :.nl 9 7 - 4U -CAS A Z C Y�.2 Plan Review (due at time o submittal): $ 6 -+1kcx ( lr+tt 3 ir- �Ci.JE 'L (, r-r- dF �-CC'� F WAN rr/L 7ini 1 6� 2e Sq. Ft. /L.Ft added: Squares BTU's Gallons Amps OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate;. that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this pennit. Plans subject to field inspection. CIRLCE ONE:: ( . (CONTRACTOR) r PERSONALREPRE�S -ENNTTAA"TIIVV�F.�/(�OWNEER)) ( CONTRATOR) PRINT NAME: JI tG� C O 3-R Iat-+d SIGNATURE: p'�ryti Bldg Valuation: $ ♦ ♦ CITY OF WHEAT RIDGE ' Building Inspection Division line ~ (303) 234-5933 Inspection (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: ,10,0 ::444 Job Address:✓ ys~ s Permit Number: ❑ No one available for inspection: Time V vt AM/PM Re-Inspection required: Yes No _ I, j' When corrections have been made, call for re-Inspection at 303-234-5933 Date: Z/,,2/"5x Inspector: DO NOT REMOVE THIS NOTICE p f 11 ♦ i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 235-2857 Fax INSPECTION NOTICE Inspection Type: .49W,& Job Address: g4gy &U4144,, e~ . Permit Number: 09g2 %e-,V g ft"' 4&Ld4 .o,2sC,ant s Z,K,~_ e 44a 0424 61r~4 _ ❑ No one available for inspection: Time SAM/PM Re-Inspection required: Yes No *When corrections have been made, call for re-inspection at 303-234-5933 Date: Inspector:; DO NOT REM VE THIS NOTICE G f 05/18/09 16:56:39 City of Wheat Ridge Page bp340-iq ESTIMATE OF VALUATIONS AND FEES mmackey THE FOLLOWING INFORMATION ARE ESTIMATES ONLY AND NOT ACTUAL VALUES. CODE-- DESCRIPTION--- -VALUATION --------FEE ---USE TAX prm Permit Fee 3,000.00 108.30 0.00 1 rvw Plan Review F 3,000.00 70.40 0.00 1-7 0" totva Total Valuati 3,000.00 0.00 0.00 use Use Tax 3,000.00 0.00 54.00 / ~ ~0 TOTAL VALUAT ION: 3,000.00 FEES VALUATI ON: 3,000.00 PERMIT FEE: 108.30 USE TAX: 54.00 OTHER FEES: 70.40 TOTAL FEES: 232.70 1 ~OFW FiEgTR~ City of Wheat Ridge Building Division m 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-235-2857 o Inspection Line: 303-234-5933 Building Permit Application Date: Plan Permit Property Address: -3691 e-4,'z,9Ao Property Owner (please print): Row oS%E2 /S ,aas Phone: Mailing Address: (if different than prop e~rty address) Address: /57 City, State, zip: 0A,6,tl ~O ~ ya3 Contractor: Nolz5ez.L IP4501Uf?N RUC. e Contractor License OC?- 00772 Phone: 0 Sub Contractors: Electrical City License Company: Exp. Date: Plumbing City License Company Exp. Date: Mechanical City License Company: Exp. Date: Use of space (description): Al8C'C' ll L~ Construction Value: $ v Description of work- + - (as calculated per the Building Valuation Data sheet) ftd'I+ ~~6 7l(G ~ ~ Plan Review (due at time of submittal): ,ftwvr,CQ¢c c/tvtvr /Go r~ r~rikt~t'~ A&7, 9q. Ft./L.Ft added: Squares BTU's Gallons Amps AJ / f~lc 6 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. 51VIrQ"fjject to field inspection. CIRLCE ONE:: (OWNE (CONTRACTOR),,nn or PERSONAL REPRES TATIVE of (O E (CONTRATOR) PRINT NAME:( i`2Ti mely ° - C%4/11f,.,~f~l SIGNATURE: Date: fL -U ON SITE PLANS MUST BE ON SITE FOR INSPECTION h "Pr ;e~ve,P►U-DY- S pe-cnol Afpa 11 K pfd of %11H A 3 ~*rf •a APPROVED Subject to Field Inspections cOOpaoo Wheat Ridge Building Department` Wheat Ridge Building Dept. Date: ~ 1 PlahCheCker" ✓ dit fpeni:Th suaticeofapermitorrapprovalofpl;;.specifcatio 3 colnputatio all not eh a permit tor, or an approval of, any violatl G any of the provisionsoHe building .code er of any City ordinances. PefrJpIs presuming togive authority to violate or catieel the provisions of building codes orother ordinances of the City shall nt.be valid,,.''` ink S(*u. -@~ ions ~ vet t=ry 7v -rte®~i~i~ SY w -sT?"4M cYtf-6 I 3691 GA,rzL-A.NP 5TP~I-I-T PIZEPA.IZEP FOIZ: MP-5. WAHL ANe W. IZON 05TL2.NAU f) MAP,CJJ 12, 2009 ®(il-~ INSP-ACTION -ENGIN-~-E-RS, INC. -ARCAITFRURAL~STRUCtURAI -~NGIN~ERS I „ (303) 279401114E (4CC3) DrmyQ s 0RIGIU41L SIN(F 1999 March 13, 2009 Mrs. Yvonne and Mr. Ron Osterhaus 3691 Garland Street Wheat Ridge, CO 80033 Re: House at 3691 Garland Street Report No: VC-47209 Dear Mr. and Mrs. Osterhaus: In accordance with your request, I visited the property at the above location on March 12, 2009 to review the structural failure of the concrete block perimeter wall/fence section at the north and to establish practical remedial action for related defects noted, without regard to other components of the property. Following is a report of my findings: The failed concrete block wall/fence section is approximately six feet high and approximately 26 feet long. The wall fell over/laterally failed due to what I understand was a strong wind from the south resulting in lateral force against the block wall. The wall was laterally weak since there is no lateral reinforcementJn the wall and it is free standing in that it is not connected at all to the adjacent wall sections at its ends. Repair/correction will require rebuilding the wall. Since the wall failed just below ground level, the wall/block foundation is intact below ground level. Only the hollow cores of the first layer/course of blocks is visible below ground. Report on THE FAILED NORTH BLOCK PERIMETER WALL SECTION of the property at 3691 Garland Street Prepared for Mrs. Yvonne and Mr. Ron Osterhaus by HOME INSPECTION ENGINEERS, INC. Denver, CO March 12, 2009 VC-47209 This report is not to be construed as a guaranty or warranty of the premises or equipment therein, or of their fitness for use. Use of this report constitutes agreement that any liability of Home Inspection Engineers, Inc., or its employees, will be limited to the fee paid for the review. No moving of furniture or other items/contents, dismantling of equipment, excavation, or tests; other than visual review, was performed. This report is furnished at your request in strict confidence for your exclusive use. It is intended to cover only such portions of the premises and the equipment therein as may be examined visually. This report details those portions of the premises and equipment that were examined. This report is limited to the areas discussed in this report. It is not intended to be exhaustive nor is it implied that every' defect was detected,. or that every component is reported upon. We warn you that, although such premises and/or equipment may be in a given condition when examined by us, if examined, the condition may change thereafter. Furthermore, this report is not to be used as a basis for determining the value of the premises, whether same is or is not to be purchased. I understand this is the opinion of the engineer, and I have read and agree to the above conditions. (signature) (date) 3691 Garland Street, Osterhaus Page Two I recommend the following: 1. Dig and review the foundation arrangement below ground level. The foundation should be at least two blocks deep, or preferably three blocks deep, resting upon a reinforced concrete footing. Based upon the findings after review below ground level, the foundation arrangement could be removed and reconstructed if need be, or since it failed laterally at ground level, the wall could be reconstructed from the present ground level block up to its six foot height. 2. The cores of the below ground concrete blocks need to be cleaned out to at least one block deep. 1 Install a #3 or greater reinforced steel rod at 16 inches center to center, continuing down at least one block depth and the core completely concrete filled. 4. Relay the block wall, placing each offset block over the vertical reinforcing steel. Fill the reinforced core with concrete all the way up to its full height. Lay steel wire reinforcement between each layer of blocks. 5. Place a capstone, as per existing, along the top of the wall. 6. As an added reinforcement at the ends, consider installing a steel channel, square steel, etc. vertical section, full height, at each wall section end with half of the channel to each side of the wall section and the adjacent wall section. The vertical steel section should not be fastened to the wall. The vertical steel section needs to extend down approximately 18" deep and the hole concrete filled with the steel section/post in place. This vertical steel section will provide lateral support at each wall junction without pulling the adjacent section over in case it has no lateral reinforcement. Enclosed is our title page/disclosure form. Please sign one copy and return it in the envelope provided. Thank you. This review was limited to the present condition of the visible items discussed above and is not a prediction of the future behavior of the building components. This review is for your exclusive use. No guarantee or warranty explicit or implicit is offered as part of this review. 3691 Garland Street, Osterhaus Page Three When I can be of further assistance, please contact my office. Building reviewed -s 01 Vance M. Kolesar, 1630 4 : Arch itectural/Stru rhU ngineer ~ vlO ~SSrONA`~ °c~. VMK:cpr sTgT~ Q. enc. 6471 LIMN144 51914.1 -IRV44U-I. CU M104 -ax: 3N-279-3199 F-MAIL: uom-El"SK c@<om<-A sr.HfT was: www.449MI svW.(0M