Loading...
HomeMy WebLinkAbout6280 W. 46th Avenuei CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: " Job Address: ,C C. Permit Number: V ❑ No one available for inspection: Time /PM Re -Inspection required: Yesf`"INo 'x When corrections are complete, schediu,- inspection online. Date. /9/Z� Inspe 1* ► � i City of Wheat Ridge '/� Residential Solar PERMIT - 202100242 PERMIT NO: 202100242 ISSUED: 02/17/2021 JOB ADDRESS: 6280 W 46th Ave EXPIRES: 02/17/2022 JOB DESCRIPTION: Install utility interactive 6.72 kw PV system on garage and house roofs; 16 panels, structural required *** CONTACTS *** OWNER (8 l 3) 787-1143 SMITH SCOTT JACOB & HEATHER SUB (720)355-7295 CHARLES W I LDE 202312 ECOLOGY SOLAR *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 18,800.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 02/17/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Frohn Submittal: Solar PV Installation Date: Monday, February 8, 2021 10:14:10 AM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 6280 W 46th Ave, Wheat Ridge, CO 80033 Property Owner Name Scott Jackson and Heather Smith Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 813-787-1143 hands61218@gmail.com Electronic Payment Form. Ddf CONTRACTOR INFORMATION Contractor Business Name Wheat Ridge Contractor's License Number (This is a 5 or 6 digit number for the Ecology Solar 202312 City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK Scope of Work KW # of Panels Location of Panels Structural required Upload engineer letter or pages on 8 1/2" x 11" only Solar Installation Plan Set on 11'x17" only. Project Value (contract value or cost of ALL materials and labor) s.bures@ecology-solar.com s.bures@ecology-solar.com Utility interactive PV on roof 6.72 16 garage and house roofs Yes Jackson Smith Enaineerina 2-6-21-1.odf Jackson Smith Plan Set 2-6-21-1.odf SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Patrick Kagen Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. W CONSULTING Scott E. Wyssling, PE, PP, CME Illumine Industries 39111 Paseo Padre Parkway Suite 313 Fremont, CA 94538 Re: To Whom It May Concern: Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 office (201) 874-3483 swysshng@wysshngconsutting. coni February 6, 2021 Engineering Services Smith Residence 6280 West 46th Avenue, Wheat Ridge CO 6.720 kW System Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site VisitNerifcation Form prepared by an Illumine Industries representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by Illumine Industries and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence and detached garage are typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug -Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used 135 MPH wind loading based on ASCE 7-16 Exposure Category "B" at a slope of 26 degrees 7 PSF = Dead Load roofing/framing Live Load = 20 PSF 3 PSF = Dead Load solar panels/mounting hardware Ground Snow Load = 30 PSF Total Dead Load =10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the 2018 International Building Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "RT -MINI Installation Manual', which can be found on the RT -MINI website (https://roof-tech.usn. If during solar panel installation, the roof framing members appear unstable or deflect non -uniformly, our office should be notified before proceeding with the installation. 2. Connection on the roof is utilizing (5) #14 screws into the existing decking to resist uplift forces. Contractor to verify installation to be performed in accordance with the A -Roof Tech recommendations. Pull out values per screw are based on National Design Specification values for CDX plywood and are identified as 208 lbs/inch. Based on W sheathing the value per screw would be 104 lbs providing 520 lbs uplift resistance per attachment. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48" o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2018 International Building Code, current industry and standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V tru`ry` yours9iPE Scott E. Wyss, Colorado License N 7 W CONSULTING) �.. SHEET CATALOG INDEX NO. DESCRIPTION T-1 COVER PAGE M-1 MOUNTING DETAIL M-2 STRUCTURAL DETAIL E-1 THREE LINE DIAGRAM PL -1 WARNING PLACARDS SS SPEC SHEET(S) SCOPE OF WORK GENERAL SYSTEM INFORMATION: SYSTEM SIZE: 6720W DC, 5584W AC MODULES: (16)HANWHA Q CELLS Q.PEAK DUO L -G8.2 420W INVERTER: (16)ENPHASE IQ7A-72-2-US, BRANCH DETAILS: 1X10, 1X6 ENPHASE BRANCHES APPLICABLE CODES • ELECTRIC CODE: NEC 2020 • FIRE CODE: IFC 2018 • BUILDING CODE: IBC 2018 • RESIDENTIAL CODE: IRC 2018 GENERAL NOTES 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING JACKSON SMITH - 6.720kW DC, 5.584kW AC N LAMAR ST APPROX 300' 130'-11" NOTE:ALL METERS ORIGINALLY INSTALLED OUTDOORS THAT, DUE TO ALTERATIONS OR ADDITIONS TO THE BUILDING, BECOME ENCLOSED WITHIN THE BUILDING STRUCTURE (EXAMPLE: ENCLOSED PATIO OR GARAGE), WHERE ACCESS THROUGH A DOORWAY IS REQUIRED, SHALL BE RELOCATED TO AN OUTDOOR LOCATION DESIGNATED BY THE COMPANY'S LOCAL ELECTRIC METER DEPARTMENT. TOTAL AREA OF ROOF (SQ.FT) 1060 TOTAL ARRAY AREA (SQ.FT) 230.2875 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%) 21.73 SCALE: 1/16" = 1'-0" PROPE 25'-4" SITE PLAN LAYOUT W 46TH AVE JAY ST APPROX 220' I*] ILITY METER kIN SERVICE PANEL DISCONNECT JPHASE IQ COMBINER 3 AXIMUM 1' SPACING NEEN COMPONENTS) UIT ON HOUSE OX 14'-18') )TOVOLTAIC ARRAY J THE ROOF TACHED STRUCTURE PROPERTY LINE VICINITY MAP Queen ofI Vietnamese Martyrs W461n A.,._ 6280 W 46th Ave, Wheat Ridge, 0.a 80033, USA PI /00001% %"tf E CO LO V Ns, SOLAR Planned P CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO PRN NUMBER: ECL -21482 ILLUMINE i Because quality matters COVER PAGE DESIGNER /CHECKED I PAPER SIZE: 17"X11" I BY: AP/HK 811-711 111 SCALE:AS NOTED NOTE:24/7 UNESCORTED KEYLESS ACCESS TOI DATE: 2/5/2021 THE METERS AND AC DISCONNECT 1:7d9J/_1 T-1 INSTALLATION NOTES 1060 SITE INFORMATION - WIND SPEED: 135 MPH AND SNOW LOAD: 30 PS 1. TRU TURAL ROOF MEMBER LOCATIONS ARE TOTAL AREA OF ARRAY SR. COVERED IN THE ROOF (%) 21.73 NO. OF ARRAY AREA ROOF FRAME ESTIMATED AND SHOULD BE LOCATED AND VERIFIED NO AZIMUTH PITCH MODULES (SQ. FT.) ROOF TYPE ATTACHMENT EXPOSURE FRAME TYPE SIZE BY THE CONTRACTOR WHEN LAG BOLT PENETRATION MP -01 2700 260 5 115.1 COMPOSITION RT MINI ATTIC PRE -FABRICATED TRUSSES 2 X 4 OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. SHINGLE 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT MP -02 900 260 5 115.1 COMPOSITION RT MINI ATTIC PRE -FABRICATED TRUSSES 2 X 4 PER CODE BY A LICENSED CONTRACTOR. SHINGLE 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. MP -03 2700 260 6 138.2 COMPOSITION RT MINI ATTIC PRE -FABRICATED TRUSSES 2 X 4 4.ALL PV RACKING ATTACHMENTS SHALL BE SHINGLE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. NOTE: PENETRATIONS ARE STAGGERED 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. ROOF ACCESS PATHWAYS AND SETBACKS: 1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUP R-3BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS 1204.2.1.1 THROUGH 1204.2.1.3. EXCEPTIONS: 1.THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURES DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL RESIDENTIAL CODE. 2.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL OR LESS. 1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THAN TWO 36 -INCH -WIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36 -INCH -WIDE (914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES 1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A PATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING 1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE. WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITHIN THE DWELLING IN ACCORDANCE WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OF THE FOLLOWING: 1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL TOTAL AREA OF ROOF (SQ.FT) 1060 TOTAL ARRAY AREA (SQ. FT) 230.2875 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%) 21.73 RIDGE. 2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL SCALE: 1"= 10'-0" Al 2 X 4 PRE -FABRICATE[` TRUSSES@ 2'-0"SPACING ALUMINIUM RAILS I_1:7:Lva721=� ARRAY MP -02 F AERIAL VIEW FRAME MAX RAIL OVER SPACING SPAN HANG FF�ns 2'-0" 4'-0" 2'-0" 2 R yar'. s g 2'-0" 4'-0" 2'-0" `d M u . i 2 2'-0" 4'-0" 2'-0" f Y ! ECOLOGY SOLAR CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO PRN NUMBER: ECL -21482 ILLUMINE I Because yuaiitymatters DO Lit MOUNTING DETAIL 45 DESIGNER /CHECKED • ;: BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 M-1 DEAD LOAD CALCULATIONS ATTACHMENT DETAIL -RT MINI MODULES DATA BOM QUANTITY LBS/UNIT TOTAL WEIGHT - RT -MINI HANWHA Q CELLS Q.PEAK DUO L -G8.2 (LBS) SOLAR MODULE RAIL RAIL L -FOOT 420W MODULES 16 55.11 881.76 MODULE DIMS 81.88"x40.5"x1.37" MID -CLAMP 20 0.050 1.00 LAG SCREWS 5/16"x3.5":2.5"MIN END -CLAMP 24 0.050 1.20 6" MAX EMBEDMENT RAIL LENGTH 127 0.680 86.36 SPLICE BAR 0 0.360 0.00 RT MINI 48 1.35 64.80 MICRO -INVERTER 16 2.38 38.08 LAG SCREW ----------------- TOTAL WEIGHT OF THE SYSTEM (LBS) 1073.20 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 368.46 WEIGHT PER SQ. FT.(LBS) 2.91 WEIGHT PER PENETRATION (LBS) 22.36 SCALE: NTS MID -CLAMP AND END -CLAMP ANATOMY ROOF FRAMING DETAILS NLESS SEL ROOF 2 PER ATTACHMENT AT TRUSS LOCATION, RT2-O SCREW WITH �GASKETED WASHER 9 OPER ATTACHMENT AT DECK MOUNT LOCATION i' 'OOLOGY MODULE MID CLAMP END CLAMP c p L A R MODULE MODULE 2 X 4 TRUSSES @2'-011SPACING CUSTOMER INFORMATION COMPOSITION SHINGLE ROOF NAME:JACKSON SMITH PHONE NUMBER:816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, —0 —`I�F V r'�ys LOAD BEARING WALLVO % WHEAT RIDGE, CO 80033 SCALE:NTS 5 GROUNDING DETAILS 39.779952, -105.066103 APN: 392-421-500-3 MODULE TO MODULE &MODULE TO RAIL GROUNDING LUG RAIL TO RAILSSivNAt E� AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO - MID CLAMP PRN NUMBER:ECL-21482 ASSEMBLY SELF -DRILLING SCREW IRONRIDGE RAIL -� ILLUMINE i MODULE AV? pow Because quality matters FRAME P:= old STRUCTURAL DETAIL RAIL DESIGNER /CHECKEC BY: AP/HK PAPER SIZE:17X11" GROUNDING MID -CLAMP T -BOLT SCALE: NTS SCALE: NTS IRONRIDGE INTERNAL SPLICE SCALE:AS NOTED REV:A DATE:2/5/2021 M-2 MICRO INVERTER SPECIFICATIONS 11uPll]gl POWER RATING 10UTH 0019 all lKell] .1R;1019 CEC WEIGHTED EFFICIENCY MAX NO OF MICRO INVERTERS/BRANCH MAX DC VOLTAGE THREE LINE DIAGRAM: DC SYSTEM SIZE - 6720W, AC SYSTEM SIZE - 5584W I ELECTRICAL NOTES ENPHASE IQ7A-72-2-US 349W 1.45A 97% 11 58V MODULE SPECIFICATION HAN W HA Q CELLS MODEL Q.PEAK DUO L -G8.2 420W MODULE POWER @ STC 420W OPEN CIRCUIT VOLTAGE:Voc 48.84V MAX POWER VOLTAGE:Vmp 41.08V SHORT CIRCUIT VOLTAGE:Isc 10.74A MAX POWER CURRENT:Imp 10.22A NOTE: 1.THE PV AC DISCONNECTS WILL INCLUDE A YELLOW W BLACK LETTERING PLACARD SAYING "PV AC DISCONNECT". 2.THE UTILITY METER WILL HAVE A YELLOW W BLACK LETTERING PLACARD SAYING" PHTOTVOLTAICSYSTEM CONNECTED" (6)HANWHA Q CELLS Q.PEAK DUO L-G8.2420W MODULES WITH (6)ENPHASE IQ7AJ2-2-US EXISTING 120/240V 1PH 60HZ METER# XCEL-ENERGY CO MTIONJ (1) BRANCH OF (6) MICRO INVERTERS UTILIT • BOXO(NIJUEQUI GRID �2 Box OR EQUI. '1 (E)150A END FED MAIN PANEL ENPHASE IQ COMBINER3 vm` lFFFif=fi — CONDUIT SCHEDULE 1 30A 2P PV Ti BREAKER CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE E GROUND G PV BREAKER AT THE E _NE SQUARE D DU221RB AC AC COMBINER WITH OPPOSITE END OF DISCONNECT NON FUSED ENPHASE X-IQ-AM1-240-3 BUSBAR 30A, 120/240V, 2P 240V,125A 8 POLE NEMA 3R 3/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 INSTALL (2)20A PV 2P (1) 10AWG THHN/THWN-2 1 BREAKERS 40 X 0.87 X 1 = 34.80A 18.13A < 34.80A (ONLY FOR SOLAR, NO -DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY LOADS TO BE ADDED) CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12AWG ENPHASE Q -CABLE PER BRANCH CIRCUIT NONE (1) 10AWG BARE COPPER 2 3/4"EMT OR EQUIV (4) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 3 3/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (10)HANWHAQ CELLS Q.PEAK DUO L -G8.2 420W MODULES WITH (UNENPHASE IQ7AJ2-2-US " " (1) BRANCH OF (10) MICRO -INVERTERS NOTE: EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT NOTE: MAIN PANEL RATING:150A, MAIN BREAKER RATING:150A 120% RULE: (150AX1.2)-150A=30A=>ALLOWABLE BACKFEED IS 30A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =1.45x1.25x16=29.00 A =>PV BREAKER = 30A ALLOWABLE BACKFEED 30A =>30A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. 1.CONDUCTORS EXPOSED TO SUNLIG SHALL BE LISTED AS SUNLIG RESISTANT PER NEC 310.10(D). 2.CONDUCTORS EXPOSED TO W LOCATIONS SHALL BE SUITABLE FOR U IN WET LOCATIONS PER NEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHF BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDI UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS NEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRO CONDUCTOR SIZED PER NEC 250.66. 7.AMBIENT TEMPERATURE CORRECTI FACTOR IS BASED ON NEC 690.31(C). 8.AMBIENT TEMPERATURE ADJUSTME FACTOR IS BASED ON NEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION PER NEC 690.7. 10.CONDUCTORS ARE SIZED PER WI AMPACITY TABLE NEC 310.15(B)(16). I COLOGY SOLAR STOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER:816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952,-105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE LIll1�1\N:AIgCgllgtel'LK�] PRN NUMBER:ECL-21482 ILLUMINE i Because quality matters THREE LINE DIAGRAM DESIGNER/CHECKEPAPER SIZE:17X11" BY: AP/HK SCALE:AS NOTED I REV:A DATE:2/5/2021 I E-1 ELECTRICAL CALCULATIONS AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> •REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF AC WIRE CALCULATIONS:- MATERIAL:COPPER &TEMPERATURE RATING:90°C INVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A) TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK -CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE 1 1.45 X 1 SO 1 = 14.50 X 1 1.25 1 18.13A 40 X 0.87 X 1 = 34.80A 18.13A < 34.80A FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY -DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY 2 1.451 X 1 SO 1 = 114.501 X 1 1.25 1= 18.13A 40 X 0.87 X 1 = 34.80A 18.13A < 34.80A 3 1.451 X 1 16 1 = 123.201 X 1 1.25 1 1 ?q FDA 40 X 0.87 X 1 = 34.80A 29.00A < 34.80A 1.CONDUCTORS EXPOSED TO SUNLIG SHALL BE LISTED AS SUNLIG RESISTANT PER NEC 310.10(D). 2.CONDUCTORS EXPOSED TO W LOCATIONS SHALL BE SUITABLE FOR U IN WET LOCATIONS PER NEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHF BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDI UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS NEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRO CONDUCTOR SIZED PER NEC 250.66. 7.AMBIENT TEMPERATURE CORRECTI FACTOR IS BASED ON NEC 690.31(C). 8.AMBIENT TEMPERATURE ADJUSTME FACTOR IS BASED ON NEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION PER NEC 690.7. 10.CONDUCTORS ARE SIZED PER WI AMPACITY TABLE NEC 310.15(B)(16). I COLOGY SOLAR STOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER:816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952,-105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE LIll1�1\N:AIgCgllgtel'LK�] PRN NUMBER:ECL-21482 ILLUMINE i Because quality matters THREE LINE DIAGRAM DESIGNER/CHECKEPAPER SIZE:17X11" BY: AP/HK SCALE:AS NOTED I REV:A DATE:2/5/2021 I E-1 WARNING PLACARD WARNIN ELECTRIC SHOCK HAZARD RATED • • WARNING: i THE CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM TEM ARE UNGROUNDED AND MAY BE • ENERGIZED LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION [PER CODE: NEC 690.54] POWER TO THIS BUILDING IS ALSO DC DISCONNECT,INVERTER NEC 690erter WARNING [To SUPPLIED FROM THE FOLLOWING [To be used when inverter is ungrounded] be used •WER RCE OUTPUT CONNECTION SOURCES WITH DISCONNECTS LOCATED WARNIN ' • DEVICE AS SHOWN SYSTEM UTILIZES ELECTRIC SHOCK HAZARD LABEL LOCATION MICRO-INVERTERS POINT OF INTERCONNECTION LOCATED UNDER TERMINALS ON BOTH LINE AND LOAD SIDES MAY (PER CODE: NEC 705.12(6)(2)(3)(6) EACH SOLAR MODULE BE ENERGIZED IN THE OPEN POSITION Not Required if Panel board is rated not less than sum of ampere ratings of all overmrrenmevl®s supplying l[] IS ALWAYS PRESENT WHEN /� DC VMODULES CAUTION: SOLAR CIRCUIT ARE EXPOSED TOS SUNLIGOLTAGE HT LABEL LOCATION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, (N) ENPHASE IQ COMBINER 3 [PER CODE: NEC 690.13(8)] RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY (N) AC DISCONNECT 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (E) MAIN SERVICE PANEL A WARN (PER CODE: IFC605.11.1.4) (E) UTILITY METER ■ , ELECTRIC SHOCK HAZARD 1_COLOGY TERMINALS ON BOTH LINE AND LOAD SIDES c p L A R MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: NEC690.13(B)] CUSTOMER INFORMATION LABEL LOCATION WARNING AC DISCONNECT,POINT OF INTERCONNECTION A SOLAR SMITH [PER CODE: NEC 690.13(8)] DUAL POWER SOURCE SEC D PHOTOVOLTAIC PHONEJACKSON PHONE NUMBER:816-719-9364 SOURCE IS PHOTOVOLTAIC ARRAYS ON ROOF WARNI Nil ELECTRIC SHOCK HAZARD SYSTEM NO USER INSIDELE PARTS LABEL LOCATION CONTACT AUTHORIZED' SERVICE WEST 46TH AVENUE, POINT OF INTERCONNECTION PROVIDE • . ASSISTANCE WHEAT IDLE, 3 WHEAT RIDGE, CO 80033 [PER CODE: NEC705.12(D)(4)] LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), CAUTION: SOLAR ELEC 39.779952, -105.066103 AC DISCONNECT L SYSTEM CONNECT APN: 392-421-500-3 [PER CODE: NEC 690.13] LABEL LOCATION AHJ:CO-CITY OF WHEAT RIDGE WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, WARNING:PHOTOVOLTAIC UL969 AS STANDARD TO WEATHER RATING (UL LISTING UTILITY:XCEL-ENERGY CO POWER SOURCE OF MARKINGS NOT REQUIRED), MIN 3/g' LETTER HEIGHT PRN NUMBER:ECL-21482 LABEL LOCATION ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN CONDUIT, COMBINER BOX THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE [PER CODE: NEC690.31(G)(3)] OPERATED WITH THE SERVICE PANEL CLOSED. RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. (PER CODE: NEC690.15 ,690.13(B)) FASTENERS APPROVED BY THE LOCAL JURISDICTION .ILLUMINE i RAPID• SOLAR PV SYSTEM EQUIPPED Because quality matters SWITCH FOR • WITH RAPID SHUTDOWN SYSTEM TURN RAPID SHUTDOWN LABEL LOCATION SWITCH TO THE WARNING PLACARDS INVERTER "OFF" POSITION TO [PER CODE: NEC 690.56(C)(3)] SHUT DOWN PV SYSTEM AND REDUCE DESIGNER/CHECKE PAPER SIZE:17"X11" SHOCK HAZARD IN THE ARRAY BY: AP/HK LABEL LOCATION SCALE:AS NOTED REV:A AC DISCONNECT, DC DISCONNECT,POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)(1)(A)) DATE:2/5/2021 PL- 1 powered by � DUO are'r� SPEC SHEET P, • '" TOP BRAND PV TOP BRA TOP BRA TOP BRA • AUSTRAL A .. AusTRAUA 2016 2017 2018 ' 2019 Phn,tnn QCELLS YIELD SECURITY O.PRO-02 235 Best polycrystalline solar module 2014 �/HOT-S Or PROTECT QCELLS VTRACEAB QUALM( 174 motlwes testetl Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 20.3%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology, Hot -Spot Protect and Traceable Quality Tra.QT"' EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). A RELIABLE INVESTMENT Inclusive 12 -year product warranty and 25 -year linear performance warranty'. STATE OF THE ART MODULE TECHNOLOGY r Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q.ANTUM Technology. See data sheet on rear for further information. THE IDEAL SOLUTION FOR: 0000 Rooftop arrays on Ground -mounted commercial/industrial solar power plants buildings Engineered in Germany � CELLS MECHANICAL SPECIFICATION Format 2080 mm x 1030 mm x 35mm (including frame) Weight 25.0 kg zgeomm iao6 mm Front Cover 3.2 mm thermally pre -stressed glass with 400 mm 366 mm anti -reflection technology comm 4x crwndmg hd.,, o 4.5 mm u4x Drel°ag. holes Back Cover Composite film 4xMo ntingal°b aemTrec er DE AIL B) �� rr.me Frame Anodised aluminium 98o M. g'gmm Cell 6 x 24 monocrystalline Q.ANTUM solar half cells ® wao mm Junction box 53-101mm x 32-60mm x 15-18mm Protection class IP67, with bypass diodes o- L.e.l saog mm Cable 4mm2Sola rcable; (+)>_1400mm,H2:1400mm x -tin Nod(DET A) 3x6mm Connector St6ubli MC4-Evo2; IP68 -I I-36 mm DETAILA 1i 6�m DETAILS LH z55 m I OI6.6mm SmmT,= ELECTRICAL CHARACTERISTICS POWER CLASS 415 420 425 430 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1(POWER TOLERANCE+5 W /-0 W) Power at MPP' PMpp [W] 415 420 425 430 Short Circuit Current' Isc [A] 10.69 10.74 10.78 10.83 E E Open Circuit Voltage' Voc [V] 48.59 48.84 49.09 49.33 "S Current at MPP IMPP [A] 10.18 10.22 10.27 10.31 Voltage at MPP VMPp [V] 40.77 41.08 41.39 41.70 Efficiency' q [%] >-19.4 >_19.6 >_19.8 2:20.1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP PMPP [W] 310.8 314.5 318.3 322.0 E Short Circuit Current Isc [A] 8.61 8.65 8.69 8.72 Open Circuit Voltage Voc [V] 45.82 46.05 46.29 46.52 c Current at MPP IMPP [A] 8.01 8.05 8.08 8.12 Voltage at MPP VMPP [V] 38.79 39.09 39.38 39.67 'Measurement tolerances PMPP ±3%; Isc; Voc ±5% at STC: 1000 W/m2, 25±2'C, AM 1.5 according to IEC 60904-3-1800 W/M2, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE uo o _ ocEL At least 98% of nominal power dur- 1 110 Intlustrysmntlertl for linear werrentles tlp ry 4ntlabrgr . tlw..nh. Ing first year. Thereafter max. 0.54% u LLo " degradation per year. At least 93.1% °- E O loo--- L ----- I ------ I-- ? of nominal power up to 10 years. At - J, 90 least 85% of nominal power up to w w mo 25 years. so--Ir-----------------li----- - i o 8g oAll data within measurement toler- ances. Full warranties in accordance Bo a with the warranty terms of the 200 400 Boo Boo i000 TB Q CELLS sales organisation of your IRRADIANCE w/.21 ° s w 16 20 2a respective country. sr.ntl.ra arm. pt gu.remee arm. Low.pmp.mea YEARS Typical module performance under low irradiance conditions in with the highest p--. m 2014(.s m: September 2014) comparison to STC conditions (25'C, 100OW/ml). a (V TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vo, [i [%/K] -0.27 0 Temperature Coefficient of PMPP y [%/K] -0.35 Nominal Module Operating Temperature NMOT [°C] 43±3 0 N PROPERTIES FOR SYSTEM DESIGN o Maximum System Voltage Vsrs [V] 1500 (IEC)/1500 (U L) PV module classification Class II Maximum Reverse Current IR [A] 20 Fire Rating based on ANSI /UL 1703 C/TYPE 1 a Max. Design Load, Push/ Pull [Pa] 3600/1600 Permitted Module Temperature -40°C -+85°C c? Max. Test Load, Push/ Pull [Pa] 5400/2400 on Continuous Duty o D o QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION cl 0 IEC 61215:2016; IEC 61730:2016; Number of Modules per Pallet 29 This data sheet complies with DIN EN 50380. Number of Pallets per Trailer (24t) 24 u 0 C F` ♦ Qtus Number of Pallets per 40' HC -Container (26t) 22 c Pallet Dimensions (L x W x H) 2150 x 1150 x 1220mm N-1 -1 Pallet Weight 779 kg 8 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation 0 and use of this product. Made in China o Hanwha Q CELLS Australia Pty Ltd g Suite 1, Level 1,15 Blue Street, North Sydney, NSW 2060, Australia I TEL +61(0)2 9016 3033 1 FAX +61(0)2 9016 3032 1 EMAIL q-cells-australiaQq-cells.com I WEB www.q-cells.com/au Engineered in Germany CELLS ECOLOGY S©LAR CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO PRN NUMBER: ECL -21482 ILLUMINE i Because qualltyinatters MODULE SPEC SHEET DESIGNER /CHECKED PAPER SIZE: 17"X11" BY: AP/HK SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -1 SPEC SHEET Data Sheet Enphase IQ 7A Microinverter Enphase Microinverters Region: AMERICAS INPUT (DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W + Module compatibility 60 -cell, 66 -cell, and 72 -cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range 18 V-58 V Min/Max start voltage 33 V / 58 V Enphase The high-powered smart grid -ready Max DC short circuit current (module Isc)3 Overvoltage class DC port 15A II Enphase IQ 7A MicroTm dramatically simplifies the DC port backfeed current 0 A Q7A M icroi nverter installation process while achieving the highest PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit system efficiency for systems with 60 -cell and OUTPUT (AC) @ 240 VAC @ 208 VAC 72 -Cell modules. Peak output power Maximum continuous output power 366 VA 295 VA 349 VA 290 VA Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ EnvoyTM, Enphase IQ Nominal (L -L) voltage/range° Maximum continuous output current Nominal frequency 240 V / 211-264 V 208 V / 183-229 V 1.45 A (240 VAC) 1.39 A (208 VAC) 60 Hz BatteryTM, and the Enphase Enlighten TM monitoring Extended frequency range 47-68 Hz and analysis software. AC short circuit fault current over 3 cycles Maximum units per 20 A (L -L) branch circuits 5.8 Arms 11 (240 VAC) 11 (208 VAC)'++► The IQ Series Microinverters extend the reliability standards set forth by previous generations and Overvoltage class AC port AC port backfeed current Power factor setting III 18 mA 1.0 undergo over a million hours of power -on testing, Power factor (adjustable) 0.85 leading ... 0.85 lagging EFFICIENCY CEC weighted efficiency MECHANICAL @240 VAC @208 VAC 97.0% 96.5% enabling Enphase to provide an industry-leading warranty Of up to 25 years. ECOLOGY Ambient temperature range -40°C to +60°C S © L A R Relative humidity range Connectortype: DC (IQ7A-72-2-US) Dimensions (HxWxD) 4% to 100% (condensing) MC4 212 mm x 175 mm x 30.2 mm (without bracket) CUSTOMER INFORMATION High Power Weight 1.08 kg (2.38 lbs) • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Cooling Approved for wet locations Natural convection — No fans Yes NAME: JACKSON SMITH PHONE NUMBER: 816-719-9364 Easy to Install Pollution degree PD3 • Lightweight and simple Enclosure Class II double -insulated, corrosion resistant polymeric enclosure ADDRESS: 6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033Communication • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Power Line Communication (PLC) Efficient and Reliable Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy 39.779952, -105.066103 • Optimized for high powered 60 -cell and 72 -cell modules Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break APN : 392-421-500-3 • Highest CEC efficiency of 97% • More than a million hours of testing Compliance disconnect required by NEC 690. CA Rule 21 (UL 1741 -SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES -0003 Class B, AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO p Class II double -insulated enclosure ' • UL listed CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC " and DC conductors, when installed according manufacturer's instructions. N:_ Smart Grid ReadyATTENTI PRN NUMBER: ECL -21482 ""'' " o ITE • Complies with advanced grid support, voltage and frequency ride- through requirements • Envoy and Internet connection required 1. No enforced DC/AC ratio. See the compatibility calculator at https:Henphase.com/en-us/support/module-compatibility. r • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741 -SA) 2. CEC peak power tracking voltage range is 38 V to 43 V. 3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility. 5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. !`� �� I I ► �eiJS quality dTi�I�CS To learn more about Enphase offerings, visit enphase.com To learn more about Enphase offerings, visit enphase.com u E N P H A S E , © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ E N P H A S E Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. J 2020-06-16 INVERTER SPEC SHEET DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -2 SPEC SHEET Data Sheet Enphase Networking Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy" printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile ConneffT CELLMODEM-03 (4G / 12 -year data plan) CELLMODEM-01 (3G / 5 -year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE -M / 5 -year data plan) where there is adequate cellular service in the installation area.) Enphase The Enphase IQ Combiner 3TI with Enphase Consumption Monitoring* CT 3 IQ EnvoyT"" consolidates interconnection CT -200 -SPLIT Circuit Breakers Split core current transformers enable whole home consumption metering (+/- 2.5%). Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. QCombiner equipment into a single and g e enc BRK-10A-2-240 BRK-15A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 X-IQ-AM1-240-3 streamlines PV and storage installations by BRK-20A-2P-240 EPLC-01 Circuit breaker, 2 pole, 20A, Eaton BR220 Power line carrier (communication bridge pair), quantity 2 providing a consistent, pre -wired solution for XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) residential applications. It offers up to four XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty 2 -pole input circuits and Eaton BR series busbar assembly. System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65A Max. fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four 2 -pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64A • � Smart Max. total branch circuit breaker rating (input) Production Metering CT 80A of distributed generation / 90A with IQ Envoy breaker included 200 A solid core pre-installed and wired to IQ Envoy ECOLOGY S0LAR L ii hI ® I�jl • • Includes IQ Envoy for communication and control •Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC MECHANICAL DATA Dimensions (WxHxD) Weight Ambient temperature range 49.5 x 37.5 x 16.8 cm (19.5' x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). 7.5 kg (16.5 lbs) 40° C to +46° C (40° to 115° F) CUSTOMER INFORMATION NAME:3ACKSON SMITH PHONE NUMBER: 816-719-9364 "i _ — bridge Cooling Natural convection, plus heat shield • Provides production metering and optional Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction i' �,, , N� r H • \ consumption monitoring Simple Reduced size from previous combiner Centered mounting brackets support single Wire sizes Altitude 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing. To 2000 meters (6,560 feet) ADDRESS: 6280 WEST 46TH AVENUE WHEAT RIDGE, CO 80033 66103 39.779952, -105.0-3 APN: 392-421-500-3 INTERNET CONNECTION OPTIONS ! l stud mounting AH3:CO-CITY OF WHEAT RIDGE Integrated Wi-Fi 802.11b/g/n • Supports back and side conduit entry Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) UTILITY:XCEL-ENERGY CO y Up to four 2 -pole branch circuits for 240 VAC plug-in breakers (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE -M) (not included) • 80 A total PV or storage branch circuits COMPLIANCE PRN NUMBER: ECL -21482 Compliance, Combiner UL 1741 Reliable CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 U*Consumption • Durable NRTL-certified NEMA type 3R enclosure Five-year warranty Compliance, IQ Envoy Production metering: ANSI C12.20 accuracy class 0.5 (PV production) UL 60601-1/CANCSA 22.2 No. 61010-1 ILLUMINE i monitoring is required for Enphase Storage Systems. o ` UL listed CABINET SPEC SHEET LISTED To learn more about Enphase offerings, visit enphase.com `� E N P H AS E6 To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. E N P H AS E 2018-09-13 %../ DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -3 SPEC SHEET RT -MINI is suitable for Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) Components Dimensions in (mm) mounting any rail system RT2-00-MINIBK o ■ with a conventional L -Foot. - PAT :PENDING o ° _ rzox--, o O Oir MINI base: 20 ea. Rafter installation Screw . 40 ea. ' Extra RT -Butyl : 10 ea.,. RT -Butyl is Roof Tech's flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV _ �� � � mounting system with Flexible Flashing 9 Y - ��Co'�'�G� certified b the ICC. Metal Flashing Retrofit Flexible Flashing CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 • f s '�" Deck installation ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 r � � Dual bolt design: M8 or 5/16" for L -Foot & 1/4"for EMC Easy tapping 1/4" Hex Bolt upper channel Shedding water? 100/ Waterproof 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE ICC screw guide \ ICC ESR -3575 ASTM2140 testing UV testing (7500 hrs.) UTILITY:XCEL-ENERGY CO s ' � PRN NUMBER: ECL -21482 ICC ESR 3575 Call Now for more details Flat lip for PV Cable M8 or 5/16" 'Hex Bolt � pp bottom channel clips s I _ _ _. ILLUMINE i 858-935-6064 — �� . P.E. Stamped Letters available at www.roof-tech.us/support Because quality matters MOUNT SPEC SHEET ro"A Roof Tec • • . roof -tech F www.r.usoof-tech rl— Smarter PV mounting solutions from top of roof to bottom line" 10620 Treena Street,- 230, San Diego, CA 92131 IL • • • . • • 858.935.6064 BDYS PNFEIR /CHECKED PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -4 SPEC SHEET /%A I RON RI DGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the in 40 High ® r worst storms years. winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. i _ XR Rails are the structural backbone preventing these results. They resist uplift, protect ® df� XR10 XR100 XR1000 against buckling and safely and efficiently transfer loads into the building structure. ® �® XR10 is a sleek, low -profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail, designed for regions with light or mounting rail. It supports a range of solar mounting rails. It's built to handle Their superior spanning capability ® W ®� �WA® no snow. It achieves spans up to 6 feet, wind and snow conditions, while also extreme climates and spans up to 12 requires fewer roof attachments,® ® �®®® while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. reducing the number of roof A.® ®� penetrations and the amount of installation time. 6'spanning capability 10'spanning capability 12'spanning capability Moderate load capability Heavy load capability Extreme load capability Clear & black anodized finish Clear & black anodized finish Clear anodized finish Internal splices available Internal splices available Internal splices available � Rail Selection ECOLOGY IlThe table below was prepared in compliance with applicable engineering codes and standards.' Values are S 0 L A R based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof CUSTOMER INFORMATION Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 hL Rail Span Snow (PSF) Wind (MPH) 49 Force -Stabilizing Curve 90 ADDRESS:6280 WEST 46TH AVENUE, Sloped roofs generate both vertical and lateral 120 WHEAT RIDGE, CO 80033 forces on mounting rails which can cause them None to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both 140 XR10 XR100 XR1000 39.779952, -105.066103 directions while resisting the twisting. This unique feature ensures greater security during extreme 160 APN : 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE weather and a longer system lifetime. 90 120 20 UTILITY:XCEL-ENERGY CO 140 160 PRN NUMBER: ECL -21482 90 30 160 ILLUMINE i Compatible with Flat &Pitched Roofs Corrosion -Resistant Materials 90 >r XR Rails are Iron Ridge offers All XR Rails are made of 6000 -series �, compatible with a range of tilt leg aluminum alloy, then protected with an 40 160 R Because quality matters FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof ■■■ roof mounting and structural corrosion, while also providing attachments. applications. a more attractive appearance. 80 160 RAIL SPEC SHEET 120 160 'Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. DESIGNER /CHECKED PAPER SIZE: 17"X11" 1� 1111 BY: AP/HK SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -5 SPEC SHEET IRON RI DOE Integrated Grounding System Installation Overview Install Roof Attachments Simplified Grounding 1 •Install appropriate roof flashing and/or standoff for roof type. For Greater Safety &Lower Cost _ • Attach L-Feet to flashing or standoff. Traditionally, solar modules are grounded by attaching 1 lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the © Prepare Rail Connections array. This process adds time and cost to the installation, • Insert splice into first rail, then secure with Grounding Strap and and often results in improper grounding, creating self-drilling screw. significant long-term safety risks. _ •Slide second rail over splice, then secure with opposite end of The IronRidge Integrated Grounding System solves these Grounding Strap and self-drilling screw. challenges by bonding modules directly to the mounting '0I""�► rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing Mount & Ground Rails • Attach rails to L-Feet and level rails. greater safety for system owners. • Install one Grounding Lug row of modules. Grounding Mid Clamp per Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and • Connect Grounding Lug to grounding conductor. the mounting rail to form secure electrical bonds, which are repeated throughout the array. I/ ECOLOGY SOLAR 1rm" � Install Modules & Clamps �Ij�/ Ii �1 1/ 1/ 1/ Ii �1/ .�/ I/�j I / I� • Install first module using End Clamps and Grounding Mid Clamps. CUSTOMER INFORMATION NAME:JACKSON SMITH 1/ NEW 02 ��/��/�� j11/�I/��/ II 1�/ /1' �// �/ ��j�1/ Install additional modules usingGroundingMid Clamps.7� p �/ ./ ./ �/•Finish ME V/0 Imo/ �j �j I/ �//1//1//1// 1/ %I� row with a second pair of End Clamps. PHONE NUMBER: 816-719-9364 I���I��I/� I / Ii Ii �1//1//1� �jl � ��/1� I�/I�j.� ��� �� ��/�./•� ��//•//�//�//�� ADDRESS:6280 WEST 46TH AVENUE, �jI/�jI/�� �® ��j��j�� �� jI//��/1//�/ �������. �w�/�/�����/�//.�//�j 4-fl Testing & Certification F11 Module Frame Compatibility The IronRidge Integrated Grounding I I WHEAT RIDGE, CO 80033 ���� �` �,�� ��/ System has been tested and certified to Y Dimension Range UL 2703 by Intertek Group plc. A 31.Omm - 51.Omm 39.779952, -105.066103 APN: 392-421-500-3 51111100 ��� AHJ:CO-CITY OF WHEAT RIDGE UL 2703 is a proposed UL standard " B 5.08mm (minimum) UTILITY:XCEL-ENERGY CO for evaluating solar module mounting Any module frames whose parameters are not listed in the and clamping devices. It ensures these provided table have not been tested for compatibility.L L-i PRN NUMBER: ECL-21482 / 3 devices will maintain strongelectrical and mechanical connections over an extended i - � �. \\ """" period of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60-cell and 72-cell solar module frames with box construction and a range of environments. ��� •°% anodization thicknesses. ; ILLUMINE i 2 Grounding Strap The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction of UL 1703, the solar module testing within the parameters stated above are compatible with the • Because qualitymatters Straps are used to bond rail-to-rail connections.Grounding Lug They are only required on the standard, including temperature and IronRidge Integrated Grounding System. humiditycycling, electrical and mechanical rail with the grounding lug. A single Grounding Lug connects an entire row load testing, and manufacturing quality � Cao to ironridge.com/Ig GROUNDING SPEC SHEET - of PV modules to the grounding conductor. reviews. DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS-6 SPEC SHEET Product data sheet DU221 RB Characteristics Safety switch, general duty, non fusible, 30A, 2 poles, 3 hp, 240 VAC, NEMA 3R, bolt -on provision Product availability : Stock - Normally stocked in distribution facility Price" : 177.00 USD Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 00785901490340 Nbr. of units in pkg. 1 Package weight(Lbs) 4.65 Ib(US) (2.11 kg) Returnability Yes Country of origin MX Packing Units Unit Type of Package 1 PCE r_ =� Main S U N N 0 Ln a Package 1 Height 5.40 in (13.716 cm) Package 1 width 7.80 in (19.812 cm) Package 1 Length 9.90 in (25.146 cm) Unit Type of Package 2 CAR ECOLOGY $ 0 L A R Number of Units in Package 2 5 Package 2 Weight 24.60 Ib(US) (11.158 kg)%v Package 2 Height 10.80 in (27.432 cm) Package 2 width 10.50 in (26.67 cm) Package 2 Length 23.80 in (60.452 cm) Unit Type of Package 3 PAL Number of Units in Package 3 160 Package 3 Weight 814.00 Ib(US) (369.224 kg) CUSTOMER INFORMATION Package 3 Height 46.50 in (118.11 cm) Package 3 width 40.00 in (101.6 cm) Package 3 Length 48.00 in (121.92 cm) NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 Product Single Throw Safety Switch L Sustainability Current Rating 30A 16Offer Certifications UL listed file E2875 ID Sustainable offer status Green Premium product ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN : 392-421-500-3 Enclosure Rating NEMA 3R o California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Disconnect Type Non -fusible disconnect switch Z Factory Installed Neutral None N REACh Regulation REACh Declaration Mounting Type Surface REACh free of SVHC Yes Number of Poles 2 Electrical Connection Lugs 0EU EU RoHS Directive Compliant RoHS Declaration AHJ:CO-CITY OF WHEAT RIDGE Duty Rating General duty Toxic heavy metal free Yes Voltage Rating 240 V AC Mercury free Yes UTILITY:XCEL-ENERGY CO Wire Size AWG 14 ... AWG 6 copper AWG 12 ... AWG 6 aluminium N RoHS exemption information Yes China RoHS Regulation China RoHS declaration Pro -active China RoHS declaration (out of China RoHS legal scope) PRN NUMBER: ECL -21482 Complementary 5 Environmental Disclosure Product Environmental Profile ILLUMINE i feause quadrty rnatttirs Short-circuit withstand 200 kA ca PVC free Yes co Maximum Horse Power Rating 3 hp 240 V AC 60 Hz 1 phase NEC 430.52 Contractual warranty c Width 7.75 in (196.85 mm) Height 9.63 in (244.60 mm) MA Warranty 18 months Depth 3.75 in (95.25 mm) o AC DISCONNECT SPEC SHEET Tightening torque 30 Ibf.in (3.39 N.m) 0.00...0.02 int (2.08 ... 13.3 mm2) AWG 14 ... AWG 6) E 0 r * Price is "List Price" and may be subject to a trade discount — check with your local distributor or retailer for actual price. N 0 DESIGNER /CHECKED BY: A P/ H K PAPER SIZE: 17"X11" Feb 4, 2021 Life Is On I SthdneE.ider Life Is On Schneider SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -7 SHEET CATALOG I JACKSON SMITH - 6.720kW DC, 5.584kW AC I VICINITY MAP 1 INDEX NO. I DESCRIPTION 1 T-1 COVER PAGE M-1 MOUNTING DETAIL M-2 STRUCTURAL DETAIL E-1 THREE LINE DIAGRAM PL -1 WARNING PLACARDS SS SPEC SHEET(S) SCOPE OF WORK GENERAL SYSTEM INFORMATION: SYSTEM SIZE: 6720W DC, 5584W AC MODULES: (16)HANWHA Q CELLS Q.PEAK DUO L -G8.2 420W INVERTER: (16)ENPHASE IQ7A-72-2-US, BRANCH DETAILS: 1X10, 1X6 ENPHASE BRANCHES APPLICABLE CODES • ELECTRIC CODE: NEC 2020 • FIRE CODE: IFC 2018 • BUILDING CODE: IBC 2018 • RESIDENTIAL CODE: IRC 2018 GENERAL NOTES 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING N LAMAR ST APPROX 300' PROPE City of `r Vvhc�t e COMMUNI"TY DEVELOPMENT dge APPROVED Reviewed for Cade Compliance Plans Examiner Date Valid of rmle: The issuance of o pem►It or WPrftW of pkns spec4katlont and computations shaN riot be a permit for, or an approval of, any violation is any of the provisions of the bunWhy rode or of ap► My ardinances. Permits preswrsng to give outhariry to vo 0& ar camel the prawoons of the aWkft coda or other armnor+at of the City shall not be VO4 Approval Notes: 1) P/V array system to have groundings stem installed per Pe Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemer ground rods per 2020 NEC Article 250.53)(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 25 25'-4" 130'-11" NOTE:ALL METERS ORIGINALLY INSTALLED OUTDOORS THAT, DUE TO ALTERATIONS OR ADDITIONS TO THE BUILDING, BECOME ENCLOSED WITHIN THE BUILDING STRUCTURE (EXAMPLE: ENCLOSED PATIO OR GARAGE), WHERE ACCESS THROUGH A DOORWAY IS REQUIRED, SHALL BE RELOCATED TO AN OUTDOOR LOCATION DESIGNATED BY THE COMPANY'S LOCAL ELECTRIC METER DEPARTMENT. TOTAL AREA OF ROOF (SQ.FT) 1060 TOTAL ARRAY AREA (SQ.FT) 230.2875 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%) 21.73 SCALE: 1/16" = 1'-0" SITE PLAN LAYOUT W 46TH AVE JAY ST APPROX 220' I*] kIN SERVICE PANEL DISCONNECT JPHASE IQ COMBINER 3 AXIMUM 1' SPACING (VEEN COMPONENTS) )TOVOLTAIC ARRAY J THE ROOF TACHED STRUCTURE Queen of Vietnamese Martyrs W461n A.,._ 6280 W 46th Ave, Wheat 1PRidge, 0.a 80033, USA PI /00001% %"tf ECOLOG`s SOLAR Planned P CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO PRN NUMBER: ECL -21482 ILLUMINE i Because quality matters COVER PAGE DESIGNER /CHECKED I PAPER SIZE: 17"X11" BY: AP/HK 811-711 111 SCALE:AS NOTED NOTE:24/7 UNESCORTED KEYLESS ACCESS TOI DATE: 2/5/2021 THE METERS AND AC DISCONNECT 1:7d9A_1 T-1 INSTALLATION NOTES 1060 SITE INFORMATION - WIND SPEED: 135 MPH AND SNOW LOAD: 30 PS 1. TRU TURAL ROOF MEMBER LOCATIONS ARE TOTAL AREA OF ARRAY SR. COVERED IN THE ROOF (%) 21.73 NO. OF ARRAY AREA ROOF FRAME ESTIMATED AND SHOULD BE LOCATED AND VERIFIED NO AZIMUTH PITCH MODULES (SQ. FT.) ROOF TYPE ATTACHMENT EXPOSURE FRAME TYPE SIZE BY THE CONTRACTOR WHEN LAG BOLT PENETRATION MP -01 2700 260 5 115.1 COMPOSITION RT MINI ATTIC PRE -FABRICATED TRUSSES 2 X 4 OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. SHINGLE 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT MP -02 900 260 5 115.1 COMPOSITION RT MINI ATTIC PRE -FABRICATED TRUSSES 2 X 4 PER CODE BY A LICENSED CONTRACTOR. SHINGLE 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. MP -03 2700 260 6 138.2 COMPOSITION RT MINI ATTIC PRE -FABRICATED TRUSSES 2 X 4 4.ALL PV RACKING ATTACHMENTS SHALL BE SHINGLE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. NOTE: PENETRATIONS ARE STAGGERED 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. ROOF ACCESS PATHWAYS AND SETBACKS: 1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUP R-3BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS 1204.2.1.1 THROUGH 1204.2.1.3. EXCEPTIONS: 1.THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURES DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL RESIDENTIAL CODE. 2.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL OR LESS. 1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THAN TWO 36 -INCH -WIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36 -INCH -WIDE (914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES 1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM)WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS. PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A PATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING 1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE. WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITHIN THE DWELLING IN ACCORDANCE WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OF THE FOLLOWING: 1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL TOTAL AREA OF ROOF (SQ.FT) 1060 TOTAL ARRAY AREA (SQ. FT) 230.2875 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%) 21.73 RIDGE. 2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL SCALE: 1"= 10'-0" Al 2 X 4 PRE -FABRICATE[` TRUSSES@ 2'-0"SPACING ALUMINIUM RAILS I_1:7:Lva721=� ARRAY MP -02 F AERIAL VIEW FRAME MAX RAIL OVER SPACING SPAN HANGR. 2'-0" 4'-0" 2'-0" 2 R yar'. s g 2'-0" 4'-0" 2'-0" `d M u . i 2 2'-0" 4'-0" 2'-0" .a i ' ■ M alu), %1v ECOLOGY SOLAR CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO PRN NUMBER: ECL -21482 ILLUMINE I Because yuaiitymatters DO•,•Li` . MOUNTING DETAIL 45 DESIGNER /CHECKED • ;: BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 M-1 DEAD LOAD CALCULATIONS ATTACHMENT DETAIL -RT MINI MODULES DATA BOM QUANTITY LBS/UNIT TOTAL WEIGHT - RT -MINI HANWHA Q CELLS Q.PEAK DUO L -G8.2 (LBS) SOLAR MODULE RAIL RAIL L -FOOT 420W MODULES 16 55.11 881.76 MODULE DIMS 81.88"x40.5"x1.37" MID -CLAMP 20 0.050 1.00 LAG SCREWS 5/16"x3.5":2.5"MIN END -CLAMP 24 0.050 1.20 6" MAX EMBEDMENT RAIL LENGTH 127 0.680 86.36 SPLICE BAR 0 0.360 0.00 RT MINI 48 1.35 64.80 F MICRO -INVERTER 16 2.38 38.08 1 CRY of TOTAL WEIGHT OF THE SYSTEM (LBS) 1073.20 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 368.46 Ariy'DFrifoh WEIGHT PER SQ. FT.(LBS) 2.91 LAG SCREW ----------------- WEIGHT PER PENETRATION (LBS) 22.36 SCALE: NTS MID -CLAMP AND END -CLAMP ANATOMY ROOF FRAMING DETAILS NLESS SEL ROOF 2 PER ATTACHMENT AT TRUSS LOCATION, RT2-O SCREW WITH �GASKETED WASHER 9 OPER ATTACHMENT AT DECK MOUNT LOCATION i' 'OOLOGY MODULE MID CLAMP END CLAMP c p L A R MODULE MODULE CUSTOMER INFORMATION 2 X 4 TRUSSES @2'-011SPACING COMPOSITION SHINGLE ROOF NAME:JACKSON SMITH PHONE NUMBER:816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, —0 —`I�F V r'�ys LOAD BEARING WALLVO % WHEAT RIDGE, CO 80033 SCALE:NTS 5 GROUNDING DETAILS 39.779952, -105.066103 APN: 392-421-500-3 MODULE TO MODULE &MODULE TO RAIL GROUNDING LUG RAIL TO RAILSSivNAt E� AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO - MID CLAMP PRN NUMBER:ECL-21482 ASSEMBLY SELF -DRILLING SCREW IRONRIDGE RAIL -� ILLUMINE i MODULE AV? pow Because quality matters FRAME P:= old STRUCTURAL DETAIL RAIL DESIGNER /CHECKEC BY: AP/HK PAPER SIZE:17X11" GROUNDING MID -CLAMP T -BOLT IRONRIDGE INTERNAL SPLICE SCALE: NTS SCALE: NTS SCALE:AS NOTED REV:A DATE:2/5/2021 M-2 MICRO INVERTER SPECIFICATIONS 11uPJI]gl POWER RATING 10UTH 0019 all lKell] .1R;1019 CEC WEIGHTED EFFICIENCY MAX NO OF MICRO INVERTERS/BRANCH MAX DC VOLTAGE THREE LINE DIAGRAM: DC SYSTEM SIZE - 6720W, AC SYSTEM SIZE - 5584W I ELECTRICAL NOTES ENPHASE IQ7A-72-2-US 349W 1.45A 97% 11 58V MODULE SPECIFICATION HAN W HA Q CELLS MODEL Q.PEAK DUO L -G8.2 420W MODULE POWER @ STC 420W OPEN CIRCUIT VOLTAGE:Voc 48.84V MAX POWER VOLTAGE:VmP 41.08V SHORT CIRCUIT VOLTAGE:Isc 10.74A MAX POWER CURRENT:ImP 10.22A Approval Notes: 1) PN array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If LIFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) NOTE: 1.THE PV AC DISCONNECTS WILL INCLUDE A YELLOW W BLACK LETTERING PLACARD SAYING "PV AC DISCONNECT". 2.THE UTILITY METER WILL HAVE A YELLOW W BLACK LETTERING PLACARD SAYING" PHTOTVOLTAICSYSTEM CONNECTED" (6)HANWHA Q CELLS Q.PEAK DUO L-G8.2420W MODULES WITH (6)ENPHASE IQ7AJ2-2-US EXISTING 120/240V 1PH 60HZ METER# XCEL-ENERGY CO MTIONJ (1) BRANCH OF (6) MICRO INVERTERS UTILIT • BOXO(NIJUEQUI GRID �2 Box OR EQUI. '1 (E)150A END FED MAIN PANEL ENPHASE IQ COMBINER3 vm` lFFFif=fi — CONDUIT SCHEDULE 1 30A 2P PV Ti BREAKER CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE Et GROUNDG PV BREAKER AT THE E _NE SQUARE D DU221RB AC AC COMBINER WITH OPPOSITE END OF DISCONNECT NON FUSED ENPHASE X-IQ-AM1-240-3 BUSBAR 30A, 120/240V, 2P 240V,125A 8 POLE NEMA 3R 3/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 INSTALL (2)20A PV 2P (1) 10AWG THHN/THWN-2 1 BREAKERS 40 X 0.87 X 1 = 34.80A 18.13A < 34.80A (ONLY FOR SOLAR, NO -DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY LOADS TO BE ADDED) CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12AWG ENPHASE Q -CABLE PER BRANCH CIRCUIT NONE (1) 10AWG BARE COPPER 2 3/4"EMT OR EQUIV (4) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 3 3/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (10)HANWHAQ CELLS Q.PEAK DUO L -G8.2 420W MODULES WITH (UNENPHASE IQ7AJ2-2-US " " (1) BRANCH OF (10) MICRO -INVERTERS NOTE: EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT NOTE: MAIN PANEL RATING:150A, MAIN BREAKER RATING:150A 120% RULE: (150AX1.2)-150A=30A=>ALLOWABLE BACKFEED IS 30A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =1.45x1.25x16=29.00 A =>PV BREAKER = 30A ALLOWABLE BACKFEED 30A =>30A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. 1.CONDUCTORS EXPOSED TO SUNLIG SHALL BE LISTED AS SUNLIG RESISTANT PER NEC 310.10(D). 2.CONDUCTORS EXPOSED TO W LOCATIONS SHALL BE SUITABLE FOR U IN WET LOCATIONS PER NEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHF BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDI UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS NEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRO CONDUCTOR SIZED PER NEC 250.66. 7.AMBIENT TEMPERATURE CORRECTI FACTOR IS BASED ON NEC 690.31(C). 8.AMBIENT TEMPERATURE ADJUSTME FACTOR IS BASED ON NEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION PER NEC 690.7. 10.CONDUCTORS ARE SIZED PER WI AMPACITY TABLE NEC 310.15(B)(16). I COLOGY SOLAR STOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER:816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952,-105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE LIll1�1\N:AIgCgllgtel'LK�] PRN NUMBER:ECL-21482 ILLUMINE i Because quality matters THREE LINE DIAGRAM DESIGNER/CHECKEPAPER SIZE:17X11" BY: AP/HK SCALE:AS NOTED I REV:A DATE:2/5/2021 I E-1 ELECTRICAL CALCULATIONS AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> •REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF AC WIRE CALCULATIONS:- MATERIAL:COPPER &TEMPERATURE RATING:90°C INVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A) TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK -CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE 1 1.45 X 1 SO 1 = 14.50 X 1 1.25 1 18.13A 40 X 0.87 X 1 = 34.80A 18.13A < 34.80A FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY -DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY 2 1.451 X 1 SO 1 = 114.501 X 1 1.25 1= 18.13A 40 X 0.87 X 1 = 34.80A 18.13A < 34.80A 3 1.45 1 X 1 16 1 = 123.201 X 1 1.25 1 1 29.00A 40 X 0.87 X 1 = 34.80A 29.00A < 34.80A 1.CONDUCTORS EXPOSED TO SUNLIG SHALL BE LISTED AS SUNLIG RESISTANT PER NEC 310.10(D). 2.CONDUCTORS EXPOSED TO W LOCATIONS SHALL BE SUITABLE FOR U IN WET LOCATIONS PER NEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHF BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDI UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS NEC 240.6 CODE SECTION. 6.AC GROUNDING ELECTRO CONDUCTOR SIZED PER NEC 250.66. 7.AMBIENT TEMPERATURE CORRECTI FACTOR IS BASED ON NEC 690.31(C). 8.AMBIENT TEMPERATURE ADJUSTME FACTOR IS BASED ON NEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION PER NEC 690.7. 10.CONDUCTORS ARE SIZED PER WI AMPACITY TABLE NEC 310.15(B)(16). I COLOGY SOLAR STOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER:816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952,-105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE LIll1�1\N:AIgCgllgtel'LK�] PRN NUMBER:ECL-21482 ILLUMINE i Because quality matters THREE LINE DIAGRAM DESIGNER/CHECKEPAPER SIZE:17X11" BY: AP/HK SCALE:AS NOTED I REV:A DATE:2/5/2021 I E-1 WARNING PLACARD WARNIN ELECTRIC SHOCK HAZARD RATED • • • WARNING: i THE CONDUCTORS OF THIS PHOTOVOLTAIC TEM ARE UNGROUNDED AND MAY BE SYSTEM • ENERGIZED LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION [PER CODE: NEC 690.54] POWER TO THIS BUILDING IS ALSO DC DISCONNECT,INVERTER NEC 690erter WARNING [To SUPPLIED FROM THE FOLLOWING [To be used when inverter is ungrounded] be used •WER RCE OUTPUT CONNECTION SOURCES WITH DISCONNECTS LOCATED AWARNIN ;' •RELOCATE DEVICE AS SHOWN mPn� ELECTRIC SHOCK HAZARD LABEL LOCATION POINT OF INTERCONNECTION SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER TERMINALS ON BOTH LINE AND LOAD SIDES MAY (PER CODE: NEC 705.12(6)(2)(3)(6) EACH SOLAR MODULE BE ENERGIZED IN THE OPEN POSITION Not Required if Panel board is rated not less than sum of ampere ratings of all overmrrenmevl®s supplying l[] .. IS ALWAYS PRESENT WHEN /� DC VMODULES CAUTION: SOLAR CIRCUIT ARE EXPOSED TOS SUNLIGOLTAGE HT LABEL LOCATION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, (N) ENPHASE IQ COMBINER 3 [PER CODE: NEC 690.13(8)] RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY (N) AC DISCONNECT 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. WARN (PER CODE: IFC605.11.1.4) (E) MAIN SERVICE PANEL A (E) UTILITY METER ■ , ELECTRIC SHOCK HAZARD 1_COLOGY TERMINALS ON BOTH LINE AND LOAD SIDES c p L A R MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: NEC690.13(B)] CUSTOMER INFORMATION LABEL LOCATION WARNING AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: NEC 690.13(8)] SOLAR SMITH DUAL POWER SOURCE SEC D PHOTOVOLTAIC PHONNAMEEJACKSON PHONE NUMBER:816-719-9364 SOURCE IS PHOTOVOLTAIC ARRAYS ON ROOF WARNI Nil ELECTRIC SHOCK HAZARD SYSTEM NO USER INSIDELE PARTS LABEL LOCATION CONTACT AUTHORIZED' SERVICE WEST 46TH AVENUE, POINT OF INTERCONNECTION PROVIDE • . ASSISTANCE 3 WHEAT RIDGE, CO 80033 WHEAT IDLE, [PER CODE: NEC705.12(D)(4)] LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), CAUTION: SOLAR ELEC 39.779952, -105.066103 AC DISCONNECT L SYSTEM CONNECT APN: 392-421-500-3 [PER CODE: NEC 690.13] LABEL LOCATION AHJ:CO-CITY OF WHEAT RIDGE WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, WARNING:PHOTOVOLTAIC UL969 AS STANDARD TO WEATHER RATING (UL LISTING UTILITY:XCEL-ENERGY CO POWER SOURCE OF MARKINGS NOT REQUIRED), MIN 3/g' LETTER HEIGHT PRN NUMBER:ECL-21482 LABEL LOCATION ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN CONDUIT, COMBINER BOX THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE [PER CODE: NEC690.31(G)(3)] OPERATED WITH THE SERVICE PANEL CLOSED. RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. (PER CODE: NEC690.15 ,690.13(B)) FASTENERS APPROVED BY THE LOCAL JURISDICTION .ILLUMINE i RAPID• SOLAR PV SYSTEM EQUIPPED Because quality matters SWITCH FOR • WITH RAPID SHUTDOWN SYSTEM TURN RAPID SHUTDOWN LABEL LOCATION SWITCH TO THE WARNING PLACARDS INVERTER "OFF" POSITION TO [PER CODE: NEC 690.56(C)(3)] SHUT DOWN PV SYSTEM AND REDUCE DESIGNER/CHECKE PAPER SIZE:17"X11" SHOCK HAZARD IN THE ARRAY BY: AP/HK LABEL LOCATION SCALE:AS NOTED REV:A AC DISCONNECT, DC DISCONNECT,POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)(1)(A)) DATE:2/5/2021 PL- 1 powered by � DUO are'r� THE IDEAL SOLUTION FOR: 0000 Rooftop arrays on Ground -mounted commercial/industrial solar power plants buildings Engineered in Germany SPEC SHEET • '" TOP BRAND PV TOP BRA TOP BRA TOP BRA • AUSTRALUI .. AusTRAUA 2016 zoi 7 2018 ' 2019 Phn,tnn QCELLS YIELD SECURITY O.PRO-02 235 Best polycrystalline solar module 2014 �/HOT-S Or PROTECT QCELLS VTRACEAB QUALM( 174 motlwes testetl Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 20.3%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology, Hot -Spot Protect and Traceable Quality Tra.QT"' EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). A RELIABLE INVESTMENT Inclusive 12 -year product warranty and 25 -year linear performance warranty'. STATE OF THE ART MODULE TECHNOLOGY r Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q.ANTUM Technology. See data sheet on rear for further information. � CELLS MECHANICAL SPECIFICATION Format 2080 mm x 1030 mm x 35mm (including frame) Weight 25.0 kg z°eomm 1308 mm Front Cover 3.2 mm thermally pre -stressed glass with 400 mm 3ga mm anti -reflection technology comm 4x crwndmg hol.,, o 4.5 mm u�,,� 4x°rel°age holes Back Cover Composite film 4xMo ntingal°b aemTrec er DE AIL B) �� R.me Frame Anodised aluminium 98o M. g'gmm Cell 6 x 24 monocrystalline Q.ANTUM solar half cells ® wao mm Junction box 53-101mm x 32-60mm x 15-18mm Protection class IP67, with bypass diodes o- Lef»I iaoo mm Cable 4mm2Sola rcable; (+)>_1400mm,H2:1400mm °" °'°`T"`A Connector St6ubli MC4-Evo2; IP68 �°"3xomm -I I-36 mm DETAILA 1i 6�m DEfAILB 1H zss m I-OIg.bmm zsmmlOI,m ELECTRICAL CHARACTERISTICS POWER CLASS 415 420 425 430 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1(POWER TOLERANCE+5 W /-0 W) Power at MPP' PMpp [W] 415 420 425 430 E Short Circuit Current' Isc [A] 10.69 10.74 10.78 10.83 Open Circuit Voltage' Voc [V] 48.59 48.84 49.09 49.33 .G Current at MPP IMPP [A] 10.18 10.22 10.27 10.31 Voltage at MPP VMPp [V] 40.77 41.08 41.39 41.70 Efficiency' q [%] >-19.4 >_19.6 >_19.8 2:20.1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP PMPP [W] 310.8 314.5 318.3 322.0 E Short Circuit Current Isc [A] 8.61 8.65 8.69 8.72 Open Circuit Voltage Voc [V] 45.82 46.05 46.29 46.52 c Current at MPP IMPP [A] 8.01 8.05 8.08 8.12 Voltage at MPP VMPP [V] 38.79 39.09 39.38 39.67 'Measurement tolerances PMPP ±3%; Isc; Voc ±5% at STC: 1000 W/m2, 25±2'C, AM 1.5 according to IEC 60904-3-1800 W/M2, NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE uo o _ ocEL At least 98% of nominal power dur- 1 110 Intlustrysmntlertl for linear wermntles tlp ry 4ntlabrgra. tlw..nh. Ing first year. Thereafter max. 0.54% u LLo " degradation per year. At least 93.1% °- E O loo--- L ----- I ------ I-- ? of nominal power up to 10 years. At - J, 90 least 85% of nominal power up to w w mo 25 years. so--Ir-----------------li----- - i 2 8g d oAll data within measurement toler- ances. Full warranties in accordance Bo a with the warranty terms of the 200 400 Boo Boo i000 TB Q CELLS sales organisation of your IRRADIANCE w/.21 ° s w 11 20 23 respective country. sr.ntl.ra term. °, gu.remee arm. LO Pv.pmp.mea YEARS Typical module performance under low irradiance conditions in with the highest p--. m 2014(.s m: September 2014) comparison to STC conditions (25'C, 100OW/ml). a (V TEMPERATURE COEFFICIENTS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of Vo, [i [%/K] -0.27 0 Temperature Coefficient of PMPP y [%/K] -0.35 Nominal Module Operating Temperature NMOT [°C] 43±3 0 N PROPERTIES FOR SYSTEM DESIGN o Maximum System Voltage Vsys [V] 1500 (IEC)/1500 (U L) PV module classification Class II Maximum Reverse Current IR [A] 20 Fire Rating based on ANSI /UL 1703 C/TYPE 1 a Max. Design Load, Push/ Pull [Pa] 3600/1600 Permitted Module Temperature -40°C -+85°C c? Max. Test Load, Push/ Pull [Pa] 5400/2400 on Continuous Duty o D o QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION cl 0 IEC 61215:2016; IEC 61730:2016; Number of Modules per Pallet 29 This data sheet complies with DIN EN 50380. Number of Pallets per Trailer (24t) 24 u 0 C F` ♦ Qtus Number of Pallets per 40' HC -Container (26t) 22 c Pallet Dimensions (L x W x H) 2150 x 1150 x 1220 mm N-1 -1 Pallet Weight 779 kg M Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation 0 and use of this product. Made in China o Hanwha Q CELLS Australia Pty Ltd g Suite 1, Level 1,15 Blue Street, North Sydney, NSW 2060, Australia I TEL +61(0)2 9016 3033 1 FAX +61(0)2 9016 3032 1 EMAIL q-cells-australiaQq-cells.com I WEB www.q-cells.com/au Engineered in Germany CELLS ECOLOGY S©LAR CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE UTILITY:XCEL-ENERGY CO PRN NUMBER: ECL -21482 ILLUMINE i Because qualltyinatters MODULE SPEC SHEET DESIGNER /CHECKED PAPER SIZE: 17"X11" BY: AP/HK SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -1 SPEC SHEET Data Sheet Enphase IQ 7A Microinverter Enphase Microinverters Region: AMERICAS INPUT (DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W + Module compatibility 60 -cell, 66 -cell, and 72 -cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range 18 V-58 V Min/Max start voltage 33 V / 58 V Max DC short circuit current (module Isc)3 15A Enphase The high-powered smart grid -ready Overvoltage class DC port II Enphase IQ 7A MicroTm dramatically simplifies the DC port backfeed current 0 A Q7A M icroi nverter installation process while achieving the highest PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit system efficiency for systems with 60 -cell and OUTPUT (AC) @ 240 VAC @ 208 VAC 72 -Cell modules. Peak output power 366 VA 295 VA - Maximum continuous output power 349 VA 290 VA Part of the Enphase IQ System, the I Q 7A Micro Nominal (L -L) voltage/range° 240 V / 211-264 V 208 V / 183-229 V Z ��j • �i integrates with the Enphase IQ EnvoyTM, Enphase IQ Maximum continuous output current 1.45 A (240 VAC) 1.39 A (208 VAC) Nominal frequency 60 Hz BatteryTM, and the Enphase Enlighten TM monitoring Extended frequency range 47-68 Hz and analysis software. AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L -L) branch circuits 11 (240 VAC) 11 (208 VAC)'++► The IQ Series Microinverters extend the reliability Overvoltage class AC port III standards set forth by previous generations and AC port backfeed current 18 mA Power factor setting 1.0 undergo over a million hours of power -on testing, Power factor (adjustable) 0.85 leading ... 0.85 lagging EFFICIENCY @240 VAC @208 VAC enabling Enphase to provide an industry-leading CEC weighted efficiency 97.0% 96.5% warranty Of up to 25 years. MECHANICAL ECOLOGY Ambient temperature range -40°C to +60°C S © L A R Relative humidity range Connectortype: DC (IQ7A-72-2-US) 4% to 100% (condensing) MC4 CUSTOMER INFORMATION Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) High Power Weight 1.08 kg (2.38 lbs) • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Cooling Natural convection — No fans NAME: JACKSON SMITH Approved for wet locations Yes PHONE NUMBER: 816-719-9364 Easy to Install Pollution degree PD3 • Lightweight and simple Enclosure Class II double -insulated, corrosion resistant polymeric enclosure ADDRESS: 6280 WEST 46TH AVENUE, • Faster installation with improved, lighter two -wire cabling Environmental category / UV exposure rating NEMA Type 6 / outdoor • Built-in rapid shutdown compliant (NEC 2014 & 2017) FEATURES WHEAT RIDGE, CO 80033Communication Power Line Communication (PLC) Efficient and Reliable Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy 39.779952, -105.066103 • Optimized for high powered 60 -cell and 72 -cell modules Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break APN : 392-421-500-3 • Highest CEC efficiency of 97% disconnect required by NEC 690. • More than a million hours of testing Compliance CA Rule 21 (UL 1741 -SA) AHJ:CO-CITY OF WHEAT RIDGE UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES -0003 Class B, p Class II double -insulated enclosure CAN/CSA-C22.2 NO. 107.1-01 ' • UL listed This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and UTILITY:XCEL-ENERGY CO NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC " and DC conductors, when installed according manufacturer's instructions. N:_ Smart Grid ReadyATTENTI PRN NUMBER: ECL -21482 • Complies with advanced grid support, voltage and frequency ride- ""'' " o ITE through requirements • Envoy and Internet connection required 1. No enforced DC/AC ratio. See the compatibility calculator at https:Henphase.com/en-us/support/module-compatibility. r • Configurable for varying grid profiles 2. CEC peak power tracking voltage range is 38 V to 43 V. !`� �� I I • Meets CA Rule 21 (UL 1741 -SA) 3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility. ► �eiJS quality dTi�I�CS 5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com E N P H A S E © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ E N P H A S E Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. INVERTER SPEC SHEET To learn more about Enphase offerings, visit enphase.com u , 2020-06-16 J DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -2 SPEC SHEET Data Sheet Enphase Networking Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy" printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile ConneffT CELLMODEM-03 (4G / 12 -year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G / 5 -year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE -M / 5 -year data plan) where there is adequate cellular service in the installation area.) Enphase The Enphase IQ Combiner 3TI with Enphase Consumption Monitoring* CT CRY of Combiner 3 IQ EnvoyT"" consolidates interconnection CT -200 -SPLIT Circuit Breakers Split core current transformers enable whole home consumption metering (+/- 2.5%). Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Q equipment into a single enclosure and BRK-10A-2-240 BRK-15A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK 20A 2P 240 EPLC-01 Circuit breaker, 2 pole, 20A, Eaton BR220 Power line carrier (communication bridge pair), quantity 2 providing a consistent, pre -wired solution for XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) residential applications. It offers up to four XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty 2 -pole input circuits and Eaton BR series busbar assembly. System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65A Max. fuse/circuit rating (output) 90A Branch circuits (solar and/or storage) Up to four 2 -pole Eaton BR series Distributed Generation (DG) breakers only (not included) • � Smart Max. continuous current rating (input from PV) Max. total branch circuit breaker rating (input) Production Metering CT 64A 80A of distributed generation / 90A with IQ Envoy breaker included 200 A solid core pre-installed and wired to IQ Envoy ECOLOGY S©LAR L ii hI ® I�jl • • Includes IQ Envoy for communication and control •Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC MECHANICAL DATA Dimensions (WxHxD) Weight Ambient temperature range 49.5 x 37.5 x 16.8 cm (19.5' x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). 7.5 kg (16.5 lbs) 40° C to +46° C (40° to 115° F) CUSTOMER INFORMATION NAME:3ACKSON SMITH PHONE NUMBER: 816-719-9364 "i _ — bridge Cooling Natural convection, plus heat shield • Provides production metering and optional Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction i' �,, , N� r H • \ consumption monitoring Simple Reduced size from previous combiner Centered mounting brackets support single Wire sizes Altitude 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing. To 2000 meters (6,560 feet) ADDRESS: 6280 WEST 46TH AVENUE WHEAT RIDGE, CO 80033 66103 39.779952, -105.0-3 APN: 392-421-500-3 INTERNET CONNECTION OPTIONS ! l stud mounting AH3:CO-CITY OF WHEAT RIDGE Integrated Wi-Fi 802.11b/g/n • Supports back and side conduit entry Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) UTILITY:XCEL-ENERGY CO y Up to four 2 -pole branch circuits for 240 VAC plug-in breakers (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE -M) (not included) • 80 A total PV or storage branch circuits COMPLIANCE PRN NUMBER: ECL -21482 Compliance, Combiner UL 1741 Reliable CAN/CSA C22.2 No. 107.1 47 CFR, Part 15, Class B, ICES 003 U*Consumption • Durable NRTL-certified NEMA type 3R enclosure Five-year warranty Compliance, IQ Envoy Production metering: ANSI C12.20 accuracy class 0.5 (PV production) UL 60601-1/CANCSA 22.2 No. 61010-1 ILLUMINE i monitoring is required for Enphase Storage Systems. o ` UL listed CABINET SPEC SHEET LISTED To learn more about Enphase offerings, visit enphase.com `� E N P H AS E6 To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. E N P H AS E 2018-09-13 %../ DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -3 SPEC SHEET RT -MINI is suitable for Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood) mounting any rail system Components RT2-00-MINIBK Dimensions in (mm) ° city with a conventional L -Foot. PAT: PENDING ° ° MINI base : 20 ea. Rafter installation Screw . 40 ea. ' Extra RT -Butyl : 10 ea.,. RT -Butyl is Roof Tech's flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV _ V mounting system with Flexible Flashing Y ECOLOGY9 R --11" �`�-�" certified b the ICC. Flexible Flashing Metal Flashing Retrofit b CUSTOMER INFORMATION NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 • f s '�" Deck installation ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 r � � Dual bolt design: M8 or 5/16" �� for L -Foot & 1/4" for EMC Easy tapping 1/4" Hex Bolt upper channel Shedding water? 100/ Waterproof 39.779952, -105.066103 APN: 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE ICC\ screw guide ICC ESR -3575 ASTM2140 testing UV testing (7500 hrs.) — - ... UTILITY:XCEL-ENERGY CO s ' � PRN NUMBER: ECL -21482 ICC ESR 3575 Call Now for more details Flat lip for M8 or 5/16" 'Hex Bolt PV Cable01, clips pp bottom channel s I _ _ _. ILLUMINE i 858-935-6064 –0. P.E. Stamped Letters available at www.roof-tech.us/support Because quality matters MOUNT SPEC SHEET ro" Roof Tec F www.r.us.. _ch • • . roof -tech _.. rl– Smarter PV mounting solutions from top of roof to bottom line" 10620 Treena Street,- 230, San Diego, CA 92131 IL • • • . • • 858.935.6064 BDYS PNFEIR /CHECKED PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -4 SPEC SHEET /%A I RON RI DGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years,CRY but the worst storms in 40 years. High winds capable of ® r - i Of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. ® _ •�I U)GG�� XR Rails are the structural backbone preventing these results. They resist uplift, protect® df� XR10 XR100 XR1000 against buckling and safely and efficiently \� � ® transfer loads into the building structure. ® � ® XR10 is a sleek, low -profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail, designed for regions with light or mounting rail. It supports a range of solar mounting rails. It's built to handle Their superior spanning capability ® W ®� ®® no snow. It achieves spans up to 6 feet, wind and snow conditions, while also extreme climates and spans up to 12 requires fewer roof attachments, ® ® while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. reducing the number of roof ® ®� penetrations and the amount of installation time. 6'spanning capability 10'spanning capability 12'spanning capability Moderate load capability Heavy load capability Extreme load capability Clear & black anodized finish Clear & black anodized finish Clear anodized finish Internal splices available Internal splices available Internal splices available � Rail Selection ECOLOGY IlThe table below was prepared in compliance with applicable engineering codes and standards.' Values are S © L A R based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof CUSTOMER INFORMATION Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 hL Rail Span Snow (PSF) Wind (MPH) 49 Force -Stabilizing Curve 90 ADDRESS:6280 WEST 46TH AVENUE, Sloped roofs generate both vertical and lateral 120 WHEAT RIDGE, CO 80033 forces on mounting rails which can cause them None to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both 140 XR10 XR100 XR1000 39.779952, -105.066103 directions while resisting the twisting. This unique feature ensures greater security during extreme 160 APN : 392-421-500-3 AHJ:CO-CITY OF WHEAT RIDGE weather and a longer system lifetime. 90 120 20 UTILITY:XCEL-ENERGY CO 140 160 PRN NUMBER: ECL -21482 90 30 160 ILLUMINE i Compatible with Flat &Pitched Roofs Corrosion -Resistant Materials 90 >r XR Rails are Iron Ridge offers All XR Rails are made of 6000 -series �, compatible with a range of tilt leg aluminum alloy, then protected with an 40 160 R Because quality matters FlashFoot and options for flat anodized finish. Anodizing prevents surface other pitched roof ■■■ roof mounting and structural corrosion, while also providing attachments. applications. a more attractive appearance. 80 160 RAIL SPEC SHEET 120 160 'Table is meant to be a simplified span chart for conveying general rail capabilities. Use approved certification letters for actual design guidance. 1� 1111 DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SC, SPEC SHEET IRON RI DOE Integrated Grounding System Installation Overview Install Roof Attachments Simplified Grounding 1 •Install appropriate roof flashing and/or standoff for roof type. For Greater Safety &Lower Cost _ Traditionally, solar modules are grounded by attaching 1 • Attach L -Feet to flashing or standoff. CRY e - lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, © Prepare Rail Connections • Insert splice into first rail, then secure with Grounding Strap and ®~ and often results in improper grounding, creating self -drilling screw. Z �� •� significant long-term safety risks. _ • Slide second rail over splice, then secure with opposite end of - - - The IronRidge Integrated Grounding System solves these Grounding Strap and self -drilling screw. challenges by bonding modules directly to the mounting '0I""�► rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing Mount & Ground Rails • Attach rails to L -Feet and level rails. greater safety for system owners. • Install one Grounding Lug row of modules. Grounding Mid Clamp per Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and • Connect Grounding Lug to grounding conductor. the mounting rail to form secure electrical bonds, which are repeated throughout the array. I/ ECOLOGY SOLAR 1rm" � Install Modules & Clamps �Ij�/ Ii �I I/ 1/ 1/ Ii �1/ .�/ I/�j I / I� • Install first module using End Clamps and Grounding Mid Clamps. CUSTOMER INFORMATION NAME:JACKSON SMITH 1/ NEW 02 ��/��/�� j11/�I/��/ II 1�/ /1' �// �/ ��j�1/ Install additional modules usingGroundingMid Clamps.7� p �/ ./ ./ �/•Finish ME V/0 Imo/ �j �j I/ row with a second pair of End Clamps. PHONE NUMBER: 816-719-9364 1/ I ��/1� ����/�./•�//•//�//�//�� ADDRESS:6280 WEST 46TH AVENUE, j�� �jI/�jI/�� �® ��j��j�� �� jI//1// �j �����/�//.�//�j Testing &Certification Module Frame Compatibility The IronRidge Integrated Grounding I I WHEAT RIDGE, CO 80033 ��� _W �// ��/ �, System has been tested and certified to Y Dimension Range UL 2703 by Intertek Group plc. 31.Omm - 51.Omm 39.779952, -105.066103 APN: 392-421-500-3A AHJ:CO-CITY OF WHEAT RIDGE UL 2703 is a proposed UL standard " B 5.08mm (minimum) UTILITY:XCEL-ENERGY CO � ® for evaluating solar module mounting Any module frames whose parameters are not listed in the and clamping devices. It ensures these provided table have not been tested for compatibility. PRN NUMBER: ECL -21482 � \�� / 3 devices will maintain strongelectrical and mechanical connections over an extended i - period of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60 -cell and environments. 72 -cell solar module frames with box construction and a range of � •°% ~' anodization thicknesses. ; ILLUMINE i 2 �' Grounding Strap The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction of UL 1703, the solar module testing within the parameters stated above are compatible with the • Because quality matters Grounding Straps are used to = bond rail -to -rail connections. Grounding Lug They are only required on the Standard, including temperature and IronRidge Integrated Grounding System. um hidit cycling, electrical and mechanical y c y g A single Grounding Lug rail with the grounding lug. connects an entire row load testing, and manufacturing quality � Cao to ironridge.com/Ig GROUNDING SPEC SHEET - of PV modules to the grounding conductor. reviews. DESIGNER /CHECKED BY: AP/HK PAPER SIZE: 17"X11" SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -6 SPEC SHEET Cft of a 'Aa IC -W �f Product data sheet DU221 RB Characteristics Safety switch, general duty, non fusible, 30A, 2 poles, 3 hp, 240 VAC, NEMA 3R, bolt -on provision Product availability : Stock - Normally stocked in distribution facility Price" : 177.00 USD Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 00785901490340 Nbr. of units in pkg. 1 Package weight(Lbs) 4.65 Ib(US) (2.11 kg) Returnability Yes Country of origin MX Packing Units Unit Type of Package 1 PCE r_ =� Main S U N N 0 Ln a Package 1 Height 5.40 in (13.716 cm) Package 1 width 7.80 in (19.812 cm) Package 1 Length 9.90 in (25.146 cm) Unit Type of Package 2 CAR ECOLOGY $ 0 L A R Number of Units in Package 2 5 Package 2 Weight 24.60 Ib(US) (11.158 kg)%v Package 2 Height 10.80 in (27.432 cm) Package 2 width 10.50 in (26.67 cm) Package 2 Length 23.80 in (60.452 cm) Unit Type of Package 3 PAL Number of Units in Package 3 160 Package 3 Weight 814.00 Ib(US) (369.224 kg) CUSTOMER INFORMATION Package 3 Height 46.50 in (118.11 cm) Package 3 width 40.00 in (101.6 cm) Package 3 Length 48.00 in (121.92 cm) NAME:JACKSON SMITH PHONE NUMBER: 816-719-9364 Product Single Throw Safety Switch L Sustainability Current Rating 30A 16Offer Certifications UL listed file E2875 ID Sustainable offer status Green Premium product ADDRESS:6280 WEST 46TH AVENUE, WHEAT RIDGE, CO 80033 39.779952, -105.066103 APN : 392-421-500-3 Enclosure Rating NEMA 3R o California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov Disconnect Type Non -fusible disconnect switch Z Factory Installed Neutral None N REACh Regulation REACh Declaration Mounting Type Surface REACh free of SVHC Yes Number of Poles 2 Electrical Connection Lugs 0EU EU RoHS Directive Compliant RoHS Declaration AHJ:CO-CITY OF WHEAT RIDGE Duty Rating General duty Toxic heavy metal free Yes Voltage Rating 240 V AC Mercury free Yes UTILITY:XCEL-ENERGY CO Wire Size AWG 14 ... AWG 6 copper AWG 12 ... AWG 6 aluminium N RoHS exemption information Yes China RoHS Regulation China RoHS declaration Pro -active China RoHS declaration (out of China RoHS legal scope) PRN NUMBER: ECL -21482 Complementary 5 Environmental Disclosure Product Environmental Profile ILLUMINE i feause quadrty rnatttirs Short-circuit withstand 200 kA ca PVC free Yes Maximum Horse Power Rating 3 hp 240 V AC 60 Hz 1 phase NEC 430.52 � Contractual warranty c Width 7.75 in (196.85 mm) Height 9.63 in (244.60 mm) MA Warranty 18 months Depth 3.75 in (95.25 mm) o AC DISCONNECT SPEC SHEET Tightening torque 30 Ibf.in (3.39 N.m) 0.00...0.02 int (2.08 ... 13.3 mm2) AWG 14 ... AWG 6) E 0 r * Price is "List Price" and may be subject to a trade discount — check with your local distributor or retailer for actual price. N 0 DESIGNER /CHECKED BY: A P/ H K PAPER SIZE: 17"X11" Feb 4, 2021 Life Is On I SthdneE.ider Life Is On Schneider SCALE:AS NOTED REV:A DATE: 2/5/2021 SS -7 INSPECTION RECORD Inspection online form: http://www.cl.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspection the following business day PERMIT: ,_�)O1 9 6Z)F&'� ADDRESS: �z,,2-t % JOB CODE: ILI Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 3 - a 01- f C6 `TD 105 Stem Walls 106 Foundation wall Insulation Do Not Pour Concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 3 - a 01- f C6 `TD 204 Plumbing Underground Int. 205 Plumbing Underground Ext. 206 Water Underground Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS PERMIT ,�p1EL6 E]�: � ADDRESS: 6 �f0 Zt) , q ,C -SOB CODE: � � Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 401 Gasline 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. 1a i CITY OF WHEAT R4DGE _1�9�Building Inspection -Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE - - Inspection Type: 2 o z - Job Address: t~/ Ll L -Lb Permit Number: o i P 0 a L a n e rz) i ❑ No one available for inspection: Time '3; 1-11 AMA& Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: 3 O-9 /)Fi Inspector: Tb DO NOT REMOVE THIS NOTICE 1a i CITY OF WHEAT R4DGE _1�9�Building Inspection -Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE - - Inspection Type: 2 o z - Job Address: t~/ Ll L -Lb Permit Number: o i P 0 a L a n e rz) i ❑ No one available for inspection: Time '3; 1-11 AMA& Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: 3 O-9 /)Fi Inspector: Tb DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Sewer Repair PERMIT - 201800868 PERMIT NO: 201800868 ISSUED: 03/28/2018 JOB ADDRESS: 6280 W 46th AVE EXPIRES: 03/28/2019 JOB DESCRIPTION: 12 foot sewer repair in back yard SDR pipe fittings strongback couplings squeegee. *** CONTACTS *** OWNER (813)787-1143 JACKSON HEATHER *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,532.00 FEES Total Valuation 0.00 Use Tax 116.17 Permit Fee 140.90 ** TOTAL ** 257.07 *** COMMENTS *** *** CONDITIONS *** ALL sewer repair/replacements for which a permit is issued MUST be inspected by and receive written approval from the City of Wheat Ridge BUILDING DIVISION, regardless of inspection by any Sanitation District representative. Inspection and approval of work by any Sanitation District representative DOES NOT grant authority to cover work without the approval of the Building Division. **For trenchless sewer replacements - The contractor will verify proper slope of new sewer piping in conformance with the IRC and IPC of 1/4 inch per foot unless otherwise allowed specifically by the applicable code. The plumbing contractor will provide verification of proper slope and drainage in writing as a condition of approval of the permitted work.** City of Wheat Ridge Residential Sewer Repair PERMIT -201800868 PERMIT NO: 201800868 ISSUED: 03/28/2018 JOB ADDRESS: 6280 W 46th AVE EXPIRES: 03/28/2019 JOB DESCRIPTION: 12 foot sewer repair in back yard SDR pipe fittings strongback couplings squeegee. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be erfed and that ork be performed is disclosed in this doc ment /or its' accompanyinVappr ved plans and specifications. r — , ignature opOVINER or CONTRACTOR (Circle one) Date 1. This p mit was issued based on the information provided in the permit application and accompanying plans and specifications and is sub' t to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shallproceed or conceal work without written approval of such work from the Building and Inspection Services Divi o 6. Th anc or gran rh o a ermit shall not be construed to be a permit for, or an approval of, an violation of any provision of any ap or or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of CW heat j'ge OMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(cDci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # Jr 9, Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: ��l? cif/ •� 7`�i /�//L-� Owner Property Owner Email: Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Contractors City License M Phone: Phone: Phone:V,--V.k', 9Z9W'1 Contractor E-mail Address: _S%® For Plan Review Questions & Comments (please print): CONTACT NAME (please prinf): Phone:l� CONTACT EMAIL(p/ease print): Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # City License # Plumbing: W.R. City License # Other City Licensed Sub: Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESIDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) , Sq. FULF Amps Btu's Gallons Squares Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNEWCONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLEONE: (OWNER)ONTK4CTOR) oHORIZEDREPRESENTATIVE) of (OWNER) (CONTRACTOR) Ir Signature (first and Inst name): 7/'y �� -��-- DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ i CITY OF WHEAT RIDGE 1 Building Inspection Division (303) 234-5933 Inspection lin /�� t C (303) 235-2855 Office • (303) 237-892 ax /' 1 t INSPECTION NOTICE Inspection Type: C OV Job Address: 7"" PLA CF_ Permit Number: ,� I SC — ZO 1 7W'i t i ME ❑ No one available for inspection: Time 1 ' _ AM/PM Re -Inspection required: Yes No When correct' ns h vvee been made, call forUre--}insp%ectio at 303-234-5933 11 Date: / Inspector: !/ ! / O NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: LA 119 Job Address: WZtO W 4uTH &yr Permit Number: '4�,C)170 59 Dq ❑ No one available for inspection: Time -,e" '_tA Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date: '1 1 ` Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Homeowner Roof PERMIT - 201703909 PERMIT NO: 201703909 ISSUED: 07/13/2017 JOB ADDRESS: 6280 W 46th AVE EXPIRES: 07/13/2018 JOB DESCRIPTION: Reroofing residential home due to hail damage. Re -roofing house, garage, and hen house. Includes felting, drip edge, flashings, hip& ridge and shingles. No redecking 22sq, *** CONTACTS *** OWNER (816)719-9364 SMITH SCOTT JACOB *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 5,654.00 FEES Total Valuation 0.00 Use Tax 118.73 Permit Fee 140.90 ** TOTAL ** 259.63 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. "b y my signature, do hereby attest that the work to be per shall comply with all accompanying approved plans and specifications, applicable building codes, anall applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this ermrt. I further attest that I am Ie 11y authorized to include all entities named within this document as parties to the work to be performed anthat all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. - J ?_ Signature of OWNETer CONTRACTOR (Circle one) Date 1. This permit wa`sis'sued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. if this permit expires, a new permit may be required to be obtained. issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of CM-A'tc�{i� g Official 0 Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. FOR OFFICE USE ONLY I PorCity of Date:/�/ Wheat Midge COMMUNITY DEVELOPMENT Pla ermit# Building & Inspection Services Division C}: V ✓ V 9 7500 W. 29th Ave., Wheat Ridge, CO 80033 Plan Review Fee: Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(o)ci.wheatridge.co.us Building Permit Application ***Please complete all highlighted areas on both sides of this form. Incomplete applications may not be -process *"* Property Address: C � J Property Owner (please print): Phone: '�; VC 1(� T1(-0'1 Property Property Owner Email: -, — L 3, -Ls�-� Mailing Address: (if different than property address) Address: City, State, Zip: Architect/Engineer E-mail: Contractor: Contractors City License #: Contractor E-mail Address: Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Phone: Phone: Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL ,•RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) (� �'C>v �\► ,�Y �r �C i vy ct , IJC.. kn, D1 tR�c C -C v1 <. Yl Pik E' 1 JOA y- a � 1 Ul�'i a---,C� Sq. Ft./LF Z 0 Amps Btu's Gallons Squares 2-2- Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER) (CON R CTOR) or ( THORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) r-- Signature (first and last name): DATE: DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer. BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ r= City of Wh6atp..id ,�ge COMMUNITY DEVELOPMENT Official Certification of Property Owner Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently reside at the project property, or intend to reside at the property for a period of one year after completion of the project, and am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, list them on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. Property Owner(s): Project Property: Notarized signature of Applicant State of Colorado } County of aS f ar_-0'e\ ) ss co O'D yr\' . t-1 tp rY' Ave The foregoing instrument was acknowledged by me this 13 � day of J , 2017 by TAMARA D ODEAN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20164015481 MY COMMISSION EXPIRES APRIL 22, 2020 My Commission Expires q J20,,o Notary Public rr 1M • Inspections will not be performed unless this card is posted requesti Call the inspection Inspector Must Sign ALL Spaces pertinent to this project Foundation Inspections Inspector Comments Initials Monolithic Slab Reinforcement Caissons Concrete. s - r Ground� OilInspector (Underground) Sewer Service (Underground) Plumbing (Below/ In -slab) Heating (Below 1 In -slab) Do Not Carver Underground or a n -Slab Wo k P.r To Approvale Above Rough Inspections Cate Inspector Comments Initials Wall Sheathing Roof Sheathing Lath i Wall Tie Rough Electric Rough Plumbing Rough Mechanical Cas Piping Rough Framing DrywallFinal� ', IIMq Jllll l i M pl Inspections nspec ni a r rls Final Plumbing Final MecWainical *rr Final Building Frame ��� inspectionsone week In advance. For landscaping and parking ROW & Drainage / Public Works Dept. inspections call 303-235-2846. For ROW and drainage 8 For •,, r Fire Inspection Protection Dist.r Protection District f• your • r. M UnMOM= 6280 W. 46th Ave. Kaleigh Boesel 303-999-5173 1 N"NaNk �ase t): Ok bnn13@yahoocom _a Address: City, State, Zip: ar . . ..... ...... .. .... ... ....... 303-438-1007 P"M I jnroofing I @comcast. net A112 -Tri lolgjcugx-� Mechanical: Complete all information on BOTH sides of this form