Loading...
HomeMy WebLinkAbout11850 W. Greenbelt ParkwayI, by my signature, do Hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work tobperformed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR)Circle one) Date 1, This permit was issued based on a to ortnation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writingand received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3• If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4• No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or g anting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable cod o any,ordtn a or regulation of this jurisdiction. Approval of work is subject to field inspection. V Signature of Chief Building Official Datc REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Comm. Accessory Stru PERMIT -201601569 PERMIT NO: 201601569 ISSUED: 10/20/2016 JOB ADDRESS: 11850 W Greenbelt PKWY EXPIRES: 10/20/2017 JOB DESCRIPTION: 225 sq ft Picnic Shelter along Clear Creek *** CONTACTS *** OWNER (303)205-7554 CITY OF WHEAT RIDGE GC (303)530-5319 Derek Walker 160208 Shelter Specialist LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: / SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 29,642.00 FEES Total Valuation 0.00 ** TOTAL ** 0.00 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A 3rd party welding inspection is required. I, by my signature, do Hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work tobperformed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR)Circle one) Date 1, This permit was issued based on a to ortnation provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writingand received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3• If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4• No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or g anting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable cod o any,ordtn a or regulation of this jurisdiction. Approval of work is subject to field inspection. V Signature of Chief Building Official Datc REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of W heat�idge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: perm its(cDci.wheatridge.co.us I FOR OFFICE USE ONLY I Date: Plan/Permit # ow Plan Review Fee: r Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: 11850 South Greenbelt Parkway Property Owner (please print): City of Wheat Ridge- Mark Ruote Phone: 303.205.7553 Property Owner Email: mruote@ci.wheatridge.co.us Mailing Address: (if different than property address) Address: 9110 West 44th Avenue City, State, Zip: Wheat Ridge, CO 80033 Architect/Engineer E-mail: mruote2d.wheatridae.co.us Phone: 303.205.7553 Contractor: Shelter Specialist., I I C Contractors City License #: 160208 Phone: 303.530.5319 Contractor E-mail Address: info(&shelterspecial ist. net Sub Contractors: Electrical: W.R. City License # Other City Licensed Sub: KECI Colorado, Inc. City License # 20449 Plumbing. W. R. City License # Other City Licensed Sub: City License # Mechanical: W.R. City License # Complete all information on BOTH sides of this form r ® COMMERCIAL ❑ RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ® COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) Picnic shelter along Clear Creek trail. Sq. Ft./LF 225 SF Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) s 29,642 00 OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this pennit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, casements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any pennit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the infonnation provided on the application. CIRCLEONE: (OWNER) (CONTRACTOR) orAUTIIORI7.E,DREPRESENTATIVE) of (014NER) CONTRACTOR) Electronic Si2nature (first and last name): Steve O'Hanlon _--DATE: 10]512016 DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ m6llj� !! r I I ' V i lima 0 V 0 w B. 1 4. ALL DIMENSIONS SHOWN SPRINGING OFF OF THE SLAB EDGE ARE MINIMUMS. OWNER TO DETERMINE SLAB SIZE PRIOR TO CONSTRUCTION. f________________________________ -------- SEE COLUMN FOUNDATION I I DETAIL ON THIS SHEET. UT I I I I 1 I I I I I I I I I 1 I I I I I I I I I 1 I I I I I I I I I I I I I I I I 11 I I I I I I I I 1 I I I y I I 1 I I I • I I 1 I I I I 1'-8• I g-0' CFN /!`FNA o FR I 1' g• FTG. 8 COL 4' 4 O ` U b tom- ,1- (2) - 04 BARS CONTINUOUS PLAN m dO -ova � 12'-0' OUT/OUT OF SLA FOUNDATION PLAN SCALE: 12' = 1'-0' (4) - M VERTICAL REBAR N3 HORIZONTAL TIES Q 8• O.C. MAX. 13' MAX., 1' MIN LEVELING NUTS METAL END NON -SHRINK GROUT 3/4'0. 24'A301 A.B: S w/ 1/4'. 3' SQUARE WASHER (w/ 13/16.0 HOLE O.C.) TACK WELDED TO HEAD. 3 d n e 3' CLEAR COLUMN FOUNDATION DETAIL COLUMN BASE REACTIONS: �o<.ww.. s< • z.o5o# Voa'ot.o.e'rA uruET - -0DO# 1 liosae-,w = 300N CCMo* o .encu = 1.800#-8 CORNS a 040 COa E 5 W�1 PSS NCP BCO G SOREW5 CNPS Ofkt�LlN SELF - SECTION B 1 A I ECRL CC -13 ECAR 1. All steel plate to be ASTM A36. light. Torque measurement is not required. n� d 3. All welling Is to be done N accordance with latest AWS standards. If welds are not specified, all welds are to develop f1.11 a strength of al component pans. F-1 4, AB bolts to be ASTM A325. Exception: Anchor bolls and all bolls smaller than 1i2'0 to be A307. NOTE: This building has been designed as a free slanding, open structure. if walls are to be added, or if the building is to C-1 o S2 adjoin another structure. or it other modifications are to be made, the structure mus, be re -engineered prior to mese S, 4/1al'I 4112 I _ S F-, S-2 S-1 C-1 m I C-1 E -1.1C 13 EC -11 TO P -J 8 P-0 EG1B _ - P I 4•-6• I yr• P-2 6 P-0 @ TOP 1•L' 9'-0• CENJCEN. OF COL.'S I _11- # 12'-0' OUT/OUT OF OF ROOF ROOF FRAMING PLAN SCALE: 1/2'' 1'-0' ROOF DECK SUPPLIER TO PRC A UNIVERSAL RIDGE CAP (SEE DETAIL ON SHEET 3) 1}' x 249a. x 50ks1 MEGA -RIB PREFINISF-FD ROOF PANELS (3'-0' COVERAGE PER SHEET) SHALL BE ATTACHED PER DETAILS ON SHT. 3. .p\YDS -- SSEtf-DOF A,PNQ1�15® NS CENSERc'OF p1Ej � F / ./ E OCNP OCAPS P HO ESP 170�1N EN II �� 114.0E 1 T it l n II 6'-0' TO BLDG. CL II II DECK EDGE DETAIL J- METAL ROOFING NOTES: CLEAR PROTECTIVE FILM MUST BE REMOVED FROM ALL METAL PRIOR TO INSTALLATION. METAL ROOFING SHOULD BE STORED INDOORS OR WHEN STORED OUTSIDE IT SHOULD BE STORED UP ON BLOCKS WITH FINISHED FACE UP AND SLOPED TO DRAIN. DURING INSTALLATION, ALL METAL SHAVINGS MUST BE REMOVED IMMEDIATELY TO AVOID RUSTING OF PANELS. I SYMM. ABOUT SECTION A 1 • E�RDDFP ANI/ s 12 95,. 4 CONTRACT NOTE: Reference accepted proposal and/or executed contract for Mimlin-llon of Items furnished by RCP Shelters. Inc. Any Pleinvso not specifically included shall be provided by owner, Installer or others. Some items are specifically noted as N.I.C. (not In comma). STEEL & HARDWARE SHOP NOTES: P1 ^of ec° T TT omTw, n Eaaa[sxo wrurtEe Mau6v_.. 1. All steel plate to be ASTM A36. light. Torque measurement is not required. 2. Steel lubes to be ASTM A500 Grade 8, Fy-46 lsl. 3. All welling Is to be done N accordance with latest AWS standards. If welds are not specified, all welds are to develop f1.11 strength of al component pans. 4, AB bolts to be ASTM A325. Exception: Anchor bolls and all bolls smaller than 1i2'0 to be A307. NOTE: This building has been designed as a free slanding, open structure. if walls are to be added, or if the building is to 5. AN hobs In steel to be 13116"0 unless rwled otherwise. o 6. Ali fabricated steel to be powder coaled; color snlecled by owner. adjoin another structure. or it other modifications are to be made, the structure mus, be re -engineered prior to mese 7. Hardware (bolls, nuts. washers. eft.) to be furnished black unless noted to be hol-cipped galvanized. Shop to -Ify hole tolerances and lolerances of threaded parts for compatibility of the galvanized pads only. modifications (by others). J CONCRETE NOTES: O 1. Remove all organic material and topsoil from slab area. Verify suitability of subgrade. Footings are to bear on undisturbed. Q natural sop a engineered fill. Both are to be compacted l0 95%Proctor density. U 2. Prepare slab with min. W compacted sand. gravel. or gushed rock. I 3. Concrete slab to be 4' Mick. Reinforce slab with 626-w1Axw1.4 welded wire fabric at mlddepN. Lap splices 8'. Ali.: Fiber LU N rr rn1 mesh admWure (min. 1.5#,c.y., nbdgated polypropylene). C- w V 4. Edge of stab to be thickened to min, 8' deep x 8' wide reinforced with 2-#4 continuous rebars. Lap splices rain. 24'. Int Building Code w/ Amendments Type of Construction: Type II -B Occupancy Classification: Assembly A-3 5. In locallons subject to Inst, install isolation pint, man. 1 8"wide, around column piers using diamond or circular layout Wire mesh shop be Interrupted at isolation joints. V w r 6. Install crack control joints (3116• wide x 1' deep) at 8'to 12'o.c. (� T. Concrete slabs In open areas are to be sloped for drainage from center to edge and away from columns. Sudace is to be Q lightly broomed or have a wood troweled finish. I W 8. Concrete slabs In enclosed areas are to have Positive drainage to poor drains and nave a troweled finish, Q < 9. Concrete stab, foundation, m4bar, wire mesh, leveling nuts, grout 6 anchor bolts (if ".tied) am N.I.C. 10. All concrete reinforcing steel to be grade 60, deformed bars. t/ / 11J J 11. F', of concrete 10 be 3000 psi @ 28 days for foundation. F'r of concrete b be 3500 psi ng 28 days for slab, air -trained. (� 12. All concrete work to be in accordance col latest ACI code. ROOF DL 13. Assumed allowable sop bearing pressures: 2000 psi vertical bearing. 150 pct passive lateral bearing. It is the Owner's 0 responsibility to verify that the allowable sop beadng values at the site meet or exceed these assumed values. If the act -I Metal Rooting d Fall 1.2 psf Misc. 0_8 values am lower than the assumed values, the foundations must be redesigned (N.I.C.). m p ERECTION NOTES: Total = 2 pst .weight of training FLOOR LL All steel members must be property braced until the complete structural system has been constructed. Correction of minor 0- misfits and a reasonable amount of reaming or alignment with drift pins will be considered a legitimate expense of erection. L=100 pst In the event of error, defect In materials. and/or workmanship of shop work which prevents proper assembling and filling up of parts by the moderate use of drift pins, or reaming, immediately report to the seller and obtain sellefs approval of the ROOF LL L=20 psf method of correction. Baits through sbtled holes in steel ate to be left finger tight only to allow for future movement. Other bolts are to be snug LU light. Torque measurement is not required. Q J NOTE: This building has been designed as a free slanding, open structure. if walls are to be added, or if the building is to o = Q adjoin another structure. or it other modifications are to be made, the structure mus, be re -engineered prior to mese (n W E modifications (by others). m O � r2V e2Y LL LL O N DE ZIGOLL lemalional L Int Building Code w/ Amendments Type of Construction: Type II -B Occupancy Classification: Assembly A-3 ( 1 � ■ ■ N Building Occupancy Category 11 % L.L Y / 777 7 Y j ^ C Building Volume = 1,260 ft' -L e; N o x ' n Or a= an) _ `� Q0 Mm ROOF DL ! /1 / 0 Y w Metal Rooting d Fall 1.2 psf Misc. 0_8 m p ■ ■ Total = 2 pst .weight of training FLOOR LL W 0- Z D' L=100 pst 0 W J ROOF LL L=20 psf J in 7C W W ROOF SL Ps = 43 Snow) co U In Fist (Ground Pr' 0.7 Po G'Ct Is = r�• Z 0K C. - 1.0. Cr - 1.2. Is = 1.0 P,= J6 Pst LL ■ ■ P. = P/ G U) J n0 4:12 Pitch: C. = 1.0. P. = 36 pst /'� Z p 0 WIND LOAD r�T96•.v 1. - ( 1 < � W y U) RallII V,a=Wh, V,•a_ IDSW$h �J v) O u1 Exposure t. Open Building w/ GC = 0 Component & Cladding Wind Pres Pressure = = y Q Q o 67 psf 8 Suction -62 psf Q 3:■ a co 0 a SEISMIC ■ S=1.0 Ss= 0.192. Sr = 0.060 in V) c 2 Site Class D (assumed) Sbs = 0.205. Sor = 0.096 of L 33 d Seismic Design Category B W 0 of Equhalent Lateral Force Procedure po J W F- C Cantikveretl Columns -Ordinary Steel Moment Frames = W R - 1.25, Cis -0.164 in cc V=4V#A ■ ■ City of Wheat COMMUNITY DEVELOPMENT Wheat Ridge BuIldIng Division Approved Plans ad. Daniel P Seymour 16-189 Plop Examiner G- r ,_ e paAwN RAR 8-77-t6 13:44:22 -05''0/0' t,r L��(.,�`(�p� V A1�11v kOFOR0 per it or ys aEv' Evz Ops 8-,7-,6 :k1Ci2C0rTIp1Jtotroru St10N t bdiMQ' / or M fdbny of the �Fj�TJ��`C,(�jLQNi+j1� �'�'ff' ,� o O- BUIL[�IGd�IOPy"%F AIp 9L g8fGNSF T ONE tp �•' DrvG ra.: SH 9934 F� a,��,��p.�p�,yl�y,b,, ^s has^ (Ell MATE�LV r�W" 1 RJt R.es o 1, ye CitylI j�[Vwy „724 IF MODIFICATION IS MADE WITHOUT EXPRESSED WRITTEN CONSENT OF RCP SHELTERS. INC.. OR IF PAYMENT IS NOT �' •' 'C 3 MADE IN FULL, THEN CERTIFICATION BECOMES NULL & VOID. OF T END PLATE Cl END OF TUBE 07 PLAN 3'0 ACCESS HOLE IN N.S. ONLY II ( 1 HSS 4x2&1196 s -z s-2 SAMEAS OPP. END T-54' TUBE LENGTH PURLIN P-1 1-REQ'D ERECTOR NOTE: SEE DECK SUPPORT CAP DETAIL FOR CAP ATTACHMENT. PLAN 3'0 ACCESS HOLE IN N.S. ONLY I ) NSS 4x2x.1196 — E S7 Sl SAME AS OPP. END T -5W TUBE LENGTH 1 1 \� PUX P� d 0 HOLE IN TOP OF TUBE S1 O \ O 13/16'0 HOLE IN BOT. OF TUBE PURLIN P-2 2-REQ'D R500040442A00.5000 PU000004x02A00.5000 CENTER PLATE ON END OF TUBE RS -1 2 REQ'D. RIDGE SUPPORT RIDGE ATTACHMENT DETAIL ERECTOR NOTES: 1. CENTER RIDGE SUPPORT ON BEAM AND ATTACH WITH 612-24 x 1 114' SELF GRILLING SCREWS G 16'0.C. AND d• MAX FROM ENDS PRIOR TO BUILDING ASSEMBLY. 2. RS TO BE CONTINUOUS ON TOP OF BEAM. EXCEPTION: RS TO STOP APPROXIMATELY 1/2' FROM EDGE OF TOP ACCESS HOLE(S). FIELD CUT RS TO LENGTH AS REOD. DECK SUPPORT CAP DETAIL 2 S2 4 43pg5 I 16. SS 5s5� �g15 H NBE a I O HOLES IN BACKER PLATE TO BE SYMM.I ABOUT O DRILLED AFTER PLATE IS WELDED TO FRAME. BOTTOM PLATE BACKER PLATE CENTER ON TUBE I 11'-7{' FRAME F-1 2-REQ'D CONSISTS OF: 2. TUBE A 2 -END PLATE(EP000005x0SA00.1196) 2 - BOTTOM PLATE (HB0408051AS400.3750) 2. BACKER PLATE (FROOO405451300.2500) or ftN PLAN 3'0 ACCESS HOLE IN N.S. ONLY (--)��/lI — HSS411196 S2 1'-7j' TUBE LENGTH PURLIN P-3 2-REQ'D ERECTOR NOTE: SEE DECK SUPPORT CAP DETAIL FOR CAP ATTACHMENT. R1302040d02A00.1196 CENTER PLATE ON END OF TUBE PLAN 3'0 ACCESS HOLE IN N.S. ONLY 0 PO000004x02A00.5000 \L^Jy HSS 4x2x.1198 EP000004x02A00.1196 CENTER PLATE ON O _ v CENTER PLATE ON END OF TUBE END OF TUBE S7 1'-7� TUBE LENGTH PURLIN P4 4-REQ'D i P, pty of 19 Wheat Ridge 44663 O � O F- IN w T- Y U N w U Q I W QLLl = J 5 U 16-189 RAR 8.17-16 REV 1: REV 2 REv REV 4: SR owc No.: SH 9934 EEC—R0. 11724 61EET- 20F3 w 0 Q o = In U) E U U ^ 3 r LL LL a U F N ZN /Yf��0^= NVI0 L (n D .� m 2 o E O 0 a a w 1n 1n Z K - O FwLU LU J w = WazZ 2 C) 3; LL ■ ■ Z-1 NE ZD w o 3 L Q mz (L ao 3 � � }U) W E 0 N J K w ~ = w 16-189 RAR 8.17-16 REV 1: REV 2 REv REV 4: SR owc No.: SH 9934 EEC—R0. 11724 61EET- 20F3 SELF DRILLING SCREWS (#l2x24xl 12- IMPAYJS. 318- HEAD). 1 EACH SIDE OF EACH RIB SCREWS TO PENETRATE TOP OF TUBE JUST 1l9a. BENT PLATE BOTTOM. RIDGE BEAM ROOF RIDGE CAP SELF -DRILLING SCREWS (#14x7/B- LAP TEK. 316- HEAD) DO NOT OVER TIGHTEN TO PREVENT DEFORMING OF MATERIAL. MEGA -RIB PREFINISHED ROOF PANELS. DECK DETAIL P. RIDGE BEAM SECTION THRU RIDGE LINE MEGA -RIB PREFINISHED ROOF PANELS 171 HEAD SCREWS 0 EN PANELS. STL. BEAM THE ACTUAL ROOF PITCH MAY VARY FROM THESE GENERAL DETAILS. SELF DRILLING SCREWS (NI2x24x1 1/7IMPA%/5, 318- HEAD), ON EACH SIDE OF EACH RIB I 36 -COVERAGE , SECTION THRU ROOFING PANEL (a) SUPPORTING MEMBER SELF DRILLING SCREWS (M12x24x1 12' IMPAX/5, 3/B -HEAD), 1 EACH SIDE OF EACH RIB. MEGA -RIB PREFINISHED ROOF PANELS. SAVE BEAM DECK DETAIL (a) EAVE BEAM 9" RIDGE CAP 26 GA 14 LN. FT. REQUIRED INSTALLATION: PTO EACH E. TRUE PLAN ELEV. VIEW CC -11 4 REQ'D. TRUE PLAN ELEV. VIEW CC -13 2 REQ'D. CPA -10 CPA -10 CLOOOOOSxO5E00.3750 �..4. CENTER ON END OF N V O TUBE p\,U%LP�\ O U 1 �y Y ui CPA -10 r LU Q �N CPA -10 Lu S-1 L PUX' P V U Q CPA -1 0 PLAN <Lu = o Q J U m y x CONN S-1 4-req'd. CONN S-2 2-req'd. 1- CPA -1 412- SQUARE COVERPLATE ASSEMBLY 2 - CPA. 3 12' SQUARE COVERPLATE ASSEMBLY 2- CPA -10 3 117• SQUARE COVERPLATE ASSEMBLY F 2- 12.O x6 ffi-BOLT 2- 12'ex61/2'BOLT O O i W 1- 3/4.0x 2 - BOLT (WITHOUT NUT) 0 J CLOOOOOSxO5A00.5000 F o0 2 Q § U N E oU_ U_ 3 O O N cq !r � N J � aJ LL Q Q J= 41 BASE PLATE N $ U��v,n0a Z N Vi Q r C . 3 PA A-7 �o�co o E Lh V) 1' ' 1 J Z SIDE a 6'4' LJf -- Y _I w = ELEV 114.0 WEEP HOLES 0 1n AT 12.0. C. ZO Z METAL DECK END CAP EC -1R (AS SHOWN) _ 02 COLUMN C-1 4-REQ'D(n ■ ■ 26 GAUGE 2-REO'D. U U)-- E Z w C 8 METAL DECK END CAP EC -1L (OPPOSITE) U= 26 GAUGE 2-REQ'D. N 1 u m T Q a p y ERECTOR NOTES: a 0 ro o a 1. BEFORE ATTACHING COVERPLATE ■ ■ 2. `7 ASSEMBLY, MAKE SURE THAT THE NUBS I{ {I ON THE BACKER PLATE FACE THE TQ U)p as COVER PLATE, UJ W 00 d 2. LOCK NUT IS PRESET IN SHOP, BUT N~.l a: MAY BE ADJUSTED SLIGHTLY IN FIELD o W IF REQ'D. FOR ERECTION. N = W 3. PLACE COVERPLATE ASSEMBLIES ON m K ■ 17-T Q EC -2 TUBES CAREFULLY SO AS TO NOT ■ SIDE SCRATCH THE PAINT ON TUBE. COVERPLATE ASSEMBLY ELEV 114.0 WEEP HOLES 4. ERECTION OF COVERPLATE ASSEMBLY: CPA -1 S CPA -10 AT 12'0. C. A. PUT ONE END OF BACKER PLATE METAL DECK END CAP EC -2 TUBE ALL. CESS ROLE AND BEHIND B. SHIFT ASSEMBLY TO ONE SIDE OF 26 GAUGE 4-REOD, ACCESS HOLE SO THAT THE OTHER END OF THE BACKER PLATE CAN SLIDE THRU THE ACCESS HOLE AND BEHIND TUBE WALL SUGGEST HOLDING A THIN PIECE OF 0. CARDBOARD OR SIMILAR MATERIAL PRa. Ro_ AGAINST TUBE TO SCRATCHING WHILE SROTECT FROM SLIDING 16-189 COVERPLATE BACK AND FORTH INTO POSITION. cfty of puwa: RAR &17-16 C. POSITION ASSEMBLY SO THAT IT IS PARALLEL WITH TUBE AND NUBS ON C— BACKER PLATE SIT INSIDE THE ACCESS HOLE W/ BACKER PLATE ORIENTED AS NEAR VERTICAL AS Rfl" DPS 8.17-16 POSSIBLE. REV 2 on REvz - r SH 6934 EEC x» ND. 11724 �--•�'��`4� SIIEEI ML „%-16„ 3OF3 i N