HomeMy WebLinkAbout8830 W. 46th PlaceX630 L/ W44 Pt,
201-7o61 �7
INSPECTION
RECORD
INSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/inspection
INSPECTION REQUEST LINE: (303) 234-5933
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Occuyar_ /Type
Inspections will not be performed unless this card is posted on the project site,
**Request an inspection before 11:59 p.m. (midnight) to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Foundation Inspections Date Inspector Comments
Initials
Pier
Concrete Encased Ground (CEG)
Foundation / P.E. Letter
Do Not Pour Concrete Prior To Anoroval Of The Above InSnpretinnc
Underground/Slab Inspections Date
Inspector Comments
Initials
Electrical
Wall Sheathing
Mid -Roof
Sewer Service
Plumbing
Do Not Cover Underground or Below/In-Slab Work Prior To Approval Of The Above Inspections
Rough Inspections
Date Inspector
Initials
Comments
Wall Sheathing
Mid -Roof
Lath / Wall Tie
Rough Electric
Rough Plumbing/Gas Line
Rough Mechanical
Rough Framing
Rough Grading
Insulation
Drywall Screw/ Nail
Final Inspections
Date
Inspector
Initials
Comments
Landscaping & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW & Drainage / Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof��
Final Window/Doors
Final Building
"DOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
For low voltage permits — Please be sure that rough inspections are completed from the Fire District and electrical low voltage
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
ti City of Wheat Ridge
Residential Roofing PERMIT - 201706187
PERMIT NO: 201706187 ISSUED: 08/16/2017
JOB ADDRESS: 8830 W 46th PL EXPIRES: 08/16/2018
JOB DESCRIPTION: Residential Re -roof to install Owens Corning asphalt shingles WITH ROOF
DECKING - 40 sq
*** CONTACTS ***
OWNER (303)836-5316 JOHNSON JARED
SUB (720)833-8718 Patrick Knight
150157 Knight Exteriors
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: UA / Unassigned BLOCK/LOM 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 13,405.00
FEES
Total Valuation 0.00
Use Tax 281.51
Permit Fee 267.70
** TOTAL ** 549.21
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
mid -roofs may be called in at the same time, one hundred percent of the sheathing must be
complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield
is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer installation instructions,
whichever is more stringent. In order to pass a final inspection of elastomeric or similar
type roof coverings, a letter of inspection and approval from the manufacturer technical
representative stating that "the application of the roof at (project address) has been
applied in accordance with the installation instruction for (roof material brand name)
roof covering" is required to be on site at the time of final inspection.
Roof inspections for ROOFS OVER 6/12 PITCH: 3rd party inspection will be required, the 3rd
party inspection report will be collected at final roof inspection performed by City of
Wheat Ridge. If report is not available the final inspection will not be completed.
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address: �Fv:o 4h -PL.
Permit Number:�f7(`,� (%
❑ No one available for inspection: Time 10: �W) M
Re -Inspection required: YesNo
When corrections have been made, call for re-iji*pection at 30334-5933
Date:
Inspector:
DO NOT REMOVE THIS NOTICE
i CITY OF WHEAT RIDGE_,..,
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: -30 -� Jam° M I D r—0F,
Job Address: P 4 (o 4 t l
Permit Number: j70
❑ No one available for inspection: Time AM
Re -Inspection required: Yes ANo
When corrections have been made, call for re -infection at 303 -2,34 -
Date: l c� I I y Inspector: