Loading...
HomeMy WebLinkAbout10675 W. 47th AvenueFrom: no-reolv(alci.wheatridae.m. us To: CommDev Perm is Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application Date: Monday, August 2, 2021 12:29:54 PM Residential Window/Door Replacement Permit Application This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and DOORS - LIKE FOR LIKE ONLY. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes replacement window(s) and/or door(s) like for like? PROPERTY INFORMATION Property Address 10675 W 47th Ave Property Owner Name Raymond Best Property Owner Phone Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Address Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" 720-272-3789 bester2@comcast.net CONTRACTOR INFORMATION Contractor Business Champion Window Co of Denver Name Contractor's License 020146 responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Steve Hemans Permit Email not displaying correctly? View it in your browser. Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address Retype Contractor Email Address DESCRIPTION OF WORK What is being replaced Number of window and/or doors being replaced Location of window(s)/door(s) being replaced (for example, master bedroom, kitchen, bathroom, etc): r`z81LOrcBefi61 shemans@getchampion.com shemans@getchampion.com NVA Morel, 3 Livingroom, bedroom What is the u -value of .28 the window(s)/door(s)? City of Wheat Ridge requires the u -value to be .30 or better on windows.. Attach copy of Best2.odf window/door cut sheets showing sizes and u - value Project Value (contract 4097.00 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Solar PV Installation Date: Friday, April 30, 2021 3:37:18 PM Solar PV Installation This application is exclusively for Solar PV Installations YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Is this application for Yes Solar PV Installation? PROPERTY INFORMATION Property Address 10675 W 47th Ave. Wheat Ridge, CO 80033 Property Owner Name Raymond Best Property Owner Phone 720-272-3789 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email bester2@comcast.net Address Attach City of Wheat 10675 CC.Ddf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" CONTRACTOR INFORMATION Contractor Business Titan Solar Power CO Name Wheat Ridge 202247 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123- 4567) Contractor Email Address 480-237-2375 copermitting@titansolarpower.com Retype Contractor copermitting@titansolarpower.com Email Address DESCRIPTION OF WORK Scope of Work Installation of a 3.330 kW DC solar system. KW 3.330 # of Panels 9 Location of Panels house roof Structural required No Upload engineer letter 10675 W 47th Ave Wheat Ridge CO 80033 SL.Ddf or pages on 8 1/2" x 11" only Solar Installation Plan 10675 W 47th Ave Wheat Ridae CO 80033 Plans.odf Set on 11'x17" only. Project Value (contract 17982 value or cost of ALL materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Erica Ford Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM v TITAN .. R P O W E R 1-855—SAY—SOLAR 525 W BASELINE ROAD MESA, AZ 85210 EC.0101592 Digitally signed by David C. Hernandez David C. Hernandez Date: 2021.04.29 19:31:16 -04:00 04,29,21 rr 52158 � Exp. 10/31 /21 '6.0 U�N 7. 1C 1-0 0 PFW- 1�P 0, Approval Notes. tLECTRICAL POWER & SAFETY CO. 1) PN array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 PJEC Article 250.104(A)(B) Eldorado 4 Li- NORIrk Crescent Springs \\, 4 WESTAMIhL TEq T� r��. Broo, infield- I' Rocky Flats Coal Creek National NORTH CFNTRAI 1 i Wildlife wEsrMINSTER• � Nsxalhglenn Refuge TMIIMSTEAi", : �� f=ederal Thornton _ Heights Derbyi� White Westminster Mf '#3 Ranch Park• ak.1"'.1" ., A 4 ` iy1 RaLS10N VALLLY 4s Twin Les Na' a� ._� Cornrrieree _do CRY North TablI, 10675 W 471h l� Mounlain Park Ave, Wheat Ridge, PQ... N1 -i I . 'Test Trailhead � I�IiI��Gf.�l'�ip. �� y • � � -- -niennial Golders 'li 1�I oenver Zoo / � ;'l.0D me Pc�fiC APPLE1�f4R I. Trailhead Clear Greek!% V ---------- Denver ---- — ------ 10, ---- - 'lest Pleaser,l - anb`0n Pc7fl{ hfle'u4 C .". -CENTRAL Genesee Park William F Lakewood lendale -�� i layderl Greer, Genesee a = Mountain Park - SOUTH Kittredge , • Englewood � „e �l�rg?�ET'I I�IARST4AIY1 Mar'' Gherr Ro 10675 W 47TH AVE WHEAT RIDGE, CO 8001L L 1*644 3.330 kW DC -STC / 3.000 kW -AC Wli6atp, `"Y °` 27/APR/21 �Mdge APPROVED ReviewQd f r Code omod �.pliance 1=t Plans Examiner Date �. Yid of rmit: ass to f a po Of pkns spec*owft anct computations sham not be a perrnlrtir, or an approval Of ony ve010oon to any of the proviskm cf the IL utdding rode or of ajt City ordinanceq. permNs _ preAmng to gw outAo ity to woka or cancel the pwosimns of fft. boom cis or'o+thtr" onmof the City shafi root he what SYSTEM SPECIFICATIONS SYSTEM SIZE: 3.330 kW MODULE: SILFAB SIL -370 NX NUMBER OF PANELS: 9 INVERTER: SE3000H—US (240V) OPTIMIZER: P370 RACKING SYSTEM: EVEREST CROSSRAIL 44X AHJ: WHEAT RIDGE, CO UTILITY: XCEL ENERGY — CO GOVERNING CODE: IBC 2018 IRC 2018 IFC 2018 NEC 2020 EXACTUS ENERGY NEW AGE ENGINEERING +1 833 392 2887 208-888 DUPONT STREET TORONTO, ON SHEET INDEX C1 — COVER PAGE N1 — GENERAL NOTES S1 — SITE PLAN S2 — PANEL LAYOUT S3 — STRUCTURAL DETAIL E1 — LINE DIAGRAM E2 — ELECTRICAL CALCULATIONS E3 — WARNING LABELS Al — PANEL SPECIFICATIONS A2 — RACKING SPECIFICATIONS A3 — MOUNTING SPECIFICATIONS A4 — INVERTER SPECIFICATIONS A5 — OPTIMIZER SPECIFICATIONS A6 — SAFETY PLAN C1 — COVER PAGE GENERALNOTES: THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST R EC EN T NATION AL ELECTR IC AND 13U ILIDIN G C OD ES AND STAND AR DS. AS AMENDED BY JU RIS IGTION • PV SYSTEMS SHALL BE PERMITTED TO SU PPLY A BUILDING OR OTHER STRU CTUR E IN ADD ITION TO ANY ETHER E LE C TR ICAL. S UP P L Y $Y ST EMI(S) [NEG 0 90 A(A)] a THE INSTALLA110N OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTOMO14NEC1ION SMALL BE PERFOR NED ONLY BY QUAUFIED PERSONS [NEG 6X4(Gj] • lE}ClSTlNG PLUMBIN G VENTS, SKYLIGHTS, EXHAUST OUTLETS, VEN1ILA_n0NS IN TAKE AIR CIPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. ■ INVERTERS,, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AD PH 070',)OLTAIC MOD ULES, SOUR CE -CII GUIT C OME INERS, AND C HA GE C ON TROLLERS IN TENDED FOR USE IN FV SYSTEMS SH ALL BE L STED OR FIELD LABELED FOR THE FV APP LICATION [N EC 690.4 (E)] ALL OUTDOOR ECAJIPSIT SH ALL BE NEMA 311 RATED (OR BETTER), INC LUD IN ALL ROOF MCU N7ED TRANSITION BOXES AND SWITCHES. ■ ALL E QU IP ME N7 S HALL BE PIR CP E RLQ" GR 04JN DED AN D DO N 10 ED IN AG CORD AN CE M TH N EC AIR TIC LE 2 50. SYSTEM GR OU NO IVIG SHALL BE IN AS CORDANCE WITH NEC 690.41 EQUIPMEN T GROUN DING CON DU TORS SMALLER THAN 6AArG SHALL COMPLY WITH NEC 250.1120�C ■ ALL PV SYSTEM D C GIRD LINT AND IN VER TER OUTPUT COND U C TO R S AND EQU IPIVEN T SHALL 13E PIR OT ES TED AG AIN ST OVERC URR ENT UN LESS STATED OTHERAF ISE IN NEC 690.9(A) OVERS URR EN T DE VIC ES USED IN PV SYSTEM DC C R SUITS SHALL BE L ISTED FOR USE IN FpV SYSTEMS [NEC 690-9(B)] PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE ARAPID SHUTE0WN FUNCTICMN 1N ACC ORDA.NC E WITH NEC 090-12 D 13C ONNECTING MEANS SHALL BE LOCATED IN A AS IBLE, READ ILY ACCESSIBLE LOCATION ONEG 690. 13(A:J] ALL W IR ING METHOD S SHALL BE IN ACC ORD ASIC E WITH NEC 090-31 CONN EC TORS SH ALL COMPLY WITH NEC 090,33 ALL GROU NDED C ONDU C70R SHALL COMPLY WITH NEC 200-6 PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOU RCE(S) A T ANY D ISTRIBUTION EQU IPIVENT ON TH E FREMItSES SH ALL WET THE FO 0 [NEG 705-12]: 1) EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED GIR GUIT BREAKER OR FUSIBLE DISCONNECTING MEANS. [NEC 705.12(A)] 2)L THE POWER SOURCE OUTPUT CIRCUIT CURRENT MULTIPLIED BY 125 PERCENT SHALL BE U SED IN ALF ACI TY C ALC U LAT 10 N S [HED 70& 12(8)] 3) EQUIPMENT 0 ONTAINING OVER CURREN T DEV IC ES IN CIR QUITS SU PIPLYING POWER TO A BUS BAR OR SON DU CTOR SHALL BE MkRKED TO IN DICATE THE PRESENC E OF ALL SOURCES. [NEC 705AW]] 4j GIRCIJ IT EP. EAKER, F: BACK FED, SHALL BE SU ITAELE FOR SUC H OPERATION. [NEC WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL, BE INSTALLED AT THE OPPOSITE END OF THE EJ SEAR OF THE MAIN 131REAFER. TO REDUCE FIRE HAZAFMS., DC FV SYSTEMS WI LEE EC)U IPPED 'hV ITH AGROUND FAULT PROTECTION SvS TEM INACCOR DAINCE %VITH NEC 090.41(8) WHERE GROUND -FAUL7 PROTECTION tS USEDE Tri E OSLI TPU TOF AN INTERACTIVE SYSTEM SHALL BE C ON NECTED TO THE SU PPL.Y SID E -Z OF- THE GR OUND FAULT PROTECTION [NEC 7705 32] is ALL PLAQUES AND SIGNAGE REQUIRED BY THE. LATEST EDIT K:IN OF NAT ION AL ELES TP. CODE LA13EL SHALL BE METALL IC OR PLASTIC, ENGRAVED OR MAZHINE PRINTED IN A CONT RAST F-4 G C CLOR TO THE PLAQU E.. PLAQUE SH ALL 13E U V RES11STAN T F EXP OSE D TO SUN U G HT. In ALL THE NEC REQUIRED WARNING SICNS, MAR 19INGS. AND LAEELS SHALL BE POSTED ON EQUIPVIENT . AND DISCONNECTS PRIOR TO ANY INSP�:EC TIONS TO BE PERFORIVED BY THE BUILD f4G DEFARTWENT. 4 CONNECTORS SHALL EE OF LATCH ff,`llG3 OR LOCEZING TYPE. CONNECTORS THAT AIRE READ ILY ACC"E.SSIB LE AND OPERA71NG AT OVER 30 VOLTS SH ALL R EMU IRE TOOL TO OPEN AND hAARIEEE D'OO NOT 0 IS COSI NECT UN DER LOAD " OR "NOT FOR CUR RENT INTERR UPTINGO. M ER E MATING CONN EC TORS AR E NOT 0�0_ THE ID ENTICALTYPE AND BRAN D. THEY SHALL BE LISTED AN D ID EN TIF IED FOR IINN TERMATAJBILATY, AS DESCRIBED IN THE MikNUFAC TURER'S INSTR UCTIONS.. [N EC 090.33�C] & (E) (2)] 4 FLEABLE, FIN E-STRAM DED CABLES SH ALL, 13E TERMINATED ONLY WITH TERMIN ALS, LUGS, DEVIC ES, OR G ON NECTORS 114 AC r.,'-'0RDAN ICE AF ITH NEC 110-14 4 WORK CLEARANCES AROUND ELECTRICAL. EQUIPMENT WILL BE.MAIN TAIISI EIS PER NEC 110.20-NA.J(1)0 14 110.2f1'AX2)A_NF3 110_2D(A):(3j. a ALL EXTER 11OR C ON DU ITS - - ITTINGS AND BOXES SHALL BE RAIN -TIGHT AND ,AP PR OVED FOR USE JN WET LOCATIONS PER NEC 314.1& 4 ROOFTOP L40UNTED PHOTOVOLTAIC PANELS AND MODULES SHALL. BE TESTED.. LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 EACH MODULE 70 BE GROUNDED USING THE SUPPLIED CONN ESTI ON PONT PER LEAN UFACT,-IRBR'S REOMAREKIEN TS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE 7013E BONDED. IF THE MSTING GROUNDING ELECTR ODE SYSTEM CAN NOT BE VER IF ED OR 15 ONLY IME TALL IC WATER PIPING, IT IS TH E C ON7RtAC-TCR,'S R ESPONSIBILITY TO IN STALL A SUPPLEMENTAL GROUND [ING ELECTRODE - a DC C ON DU GTOR S SHALL:: BE RU N IN EMT AND SH ALL BE LAB ELED .. 'C ALJ TION ID C C IRC U IT " OR, EQU IVI EVER' 5 FT_ 4 C 13N FIRM LINE SID E VOLTAGE AT R EGTR IG UTIUTY SERVICE PRIOR TO C ON NECTI %JG INVERTER_ VERIFY SERVICE VOLTAGE IS WITH IN INVERTER VOLTAGE OPERATIONAL IRAN GE - 4 S&R V I N G IJ71 L ITS' TO 18 E N 0 T! RED BEFORE ACTIVATION OF PV SYSTEM 1- 4 ELEC TRICAL CONTR ACTOR. TO PROVIDE GON DU IT EXPANSION JOINTS AIN D AN DH OR CON IDUIT RUN SAS REQUIRED PER NEC.. Nl - GENERAL NOTES DISTRIBUTION PANEL (EXT) SERVICE POINT & UTILITY METERING AC DISCONNECT INVERTER CONDUIT JUNCTION BOX 10675 W 47TH AVE DWELLING 881-101211 W 47TH AVENUE SCALE: 1 11 NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY - SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME: 0 - ALL DIMENSIONS IN FEET UNLESS - INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF ADDRESS: 04/29/21 ` OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING PHONE NUMBER: WORK PROJECT: 10675 W 47TH AVE TITAN SOLAR MUNICIPALITY: WHEAT RIDGE CO AUTHOR: EE S1 -SITE PLAN ' Exp. 10/31/21 T I T A t4 PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 CLIENT: RAYMOND E BEST WSJ:;3.330 kW DC-STC/3.000 kW -AC ,,1.� .TITANSOLARPOWER.COM - REV. - ELECTRICAL POWER 6 SAFETY CL / PVC VENT ® METAL VENT VENT BOX STRUCTURAL DELIMITER 0 SERVICE MAST O SATELLITE � ANTENNA SNOW GUARD DOWNSPOUT ELECTRICAL MOUNT RAIL TOP CHORD DECIDUOUS TREE \ TREETOP: 72' � DECIDUOUS TREE TREETOP: 74' O O DECIDUOUS TREE TREETOP: 36' 651-611 VMARA;F .oe4 4, o•. DECIDUOUS TREE J TREETOP: 46' 7r MOUNTING PATTERN SAMPLE I MAXIMUM MOUNT SPACING: 48" MOUNT PATTERN: STAGGERED ALL HARDWARE, INCLUDING MOUNTING AND RACKING, TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS. CONIFEROUS TRE TREETOP: DECIDUOUS TREES � TREETOP: 13' � L ROOF 1 PITCH 18.50 DECIDUOUS TREE DECIDUOUS TREE � / DECIDUOUS TREE TREETOP: 46' TREETOP: 38' TREETOP: 46' AZM 179 SCALE: 1 "=8' ROOF PITCH: 18.5° SLOPED SHINGLE ROOF PANEL TYPE: SILFAB SIL -370 NX ROOF 1 AREA: 554.43 FT NOTES: AZIMUTHS: 179° PANEL SIZE: 72.13" X 39.4" ARRAY AREA: 177.62 FT - SOLAR PANEL LAYOUT SUBJECT TO CHANGE RACKING TYPE. EVEREST CROSSRAIL 44X NUMBER OF PANELS. 9 o ARRAY PERCENT COVERAGE. 32.0% ACCORDING TO EXISTING CONDITIONS 0 o4i29i2� MOUNT TYPE. QUICKBOLT MICROFLASHING SYSTEM SIZE. 3.330 kW A - SCALE AS SHOWN' vm - ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED'' 58 PROJECT: 10675 W 47TH AVE TITAN SOLAR MUNICIPALITY: WHEAT RIDGE, CO AUTHOR: EE S2 -PANEL LAYOUT NAL PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 Exp. 10/31/21 U P ��J E WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST pSC� 3.330 kW DC-STC/3.000 kW -AC REV: - ELECTRICAL POWER 6 SAFETY CO. MODULE SCALE: NTS PANEL TYPE: SILFAB SIL -370 NX PANEL SIZE: 72.13" x 39.4" RACKING TYPE: EVEREST CROSSRAIL 44X MOUNT TYPE. QUICKBOLT MICROFLASHING EVEREST 44X RAIL 0111C;KROI T WOODEN STRUCTURAL MEMBER NOTES: - SCALE AS SHOWN - DIMENSIONS IN FEET UNLESS OTHERWISE STATED FLASHING LAG SCREWS SHALL BE S.S. 5/16" DIA W/ 2.5" MIN EMBED IN RAFTERS/TRUSS TOP CHORDS 04/29/21 � �N 52158 PROJECT: 10675 W 47TH AVE TITAN SOLAR MUNICIPALITY: WHEAT RIDGE, CO AUTHOR: EE S3 -STRUCTURAL DETAIL TI TA L11iAL� PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 Exp. 10/31/21 � P ��J E WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST pSCO 3.330 kW DC-STC/3.000 kW -AC REV: - ELECTRICAL POWER 6 SAFETY CO. NOTE: PV PRODUCTION METER NOT REQUIRED DUE TO THE SYSTEM SIZE BEING LESS THAN 10KW. STRING OF SILFAB SIL -370 NX MODULES EACH CONNECTED TO OPTIMIZERS L «iMAI a 15k1, 1.M"m I mk ": N VISIBLE, LOCKABLE INVERTER 1(1) NEMA3R SOLAREDGE SE3000H-US Y 30A SWITCH NON-FUSED SEE INVERTER JUNCTION BOX SUMMARY TABLE FOR / NEMA3R NUMBER OF STRINGS AND STRING LENGTHS / r1 , I 11---0­_-fit-- BI-DIRECTIONAL UTILITY METER TO BE INSTALLED BY XCEL ENERGY - CO LABELLED "PHOTOVOLTAIC SYSTEM CONNECTED" 240V, 200A MAIN SERVICE PANEL 240/120 V 10, 3W, 200A vi vv EATON DG221 URB AC ISOLATION DEVICE, NEMA 3R PV SYSTEM AC � EXISTING EQUIPPED WITH DC DISCONNECT DISCONNECT SWITCH = GEC LABELLED "PV AC DISCONNECT" WITHIN 10' OF BILLING Approval Notes: METER 1) PN array system to have grounding system installed per Part III of Article 250 per 2020 NEC Article 690.47(A). 2) If UFER ground in not available provide or verify supplemental ground rods per 2020 NEC Article 250.53(A)(3). 3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B) Inverter Inverter Inverter Number of Inverter Module Module Optimizer Optimizer String #of Circuit String DC Power AC Power DC:AC Ratio !D Manufacturer Model Inputs Input Manufacturer Model Manufacturer Madel Length Optimizers Current Power 1 SILFAB SIL -370 NX SolarEdge P370 9 9 15A 31330W 5E 9 NV1 SolarEdge SE3000H-US (240V) 2 3133dW 31000W 1.11 2 SILFAB SIL -370 NX SolarEdge P370 0 0 15A OW TITAN SOLAR PROJECT: 10675 W 47TH AVE MUNICIPALITY: WHEAT RIDGE, COI T A 11 AUTHOR: EE E1 -LINE DIAGRAM PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC REV: - city of S./D.ZoZ/ 04/29/21 �. 0 0��C � 0N 52158 Exp. 10/31/21 %NAt. PSCO DC CONDUCTOR SCHEDULE MODULES TO JUNCTION BOX *TEMPERATURE FACTOR IS BASED ON 2% DRYBULB HIGH TEMPERATURE OF 31.4°C WITH A O*C TEMPERATURE ADDER THEREFORE RACEWAYS MUST BEAT LEAST0.75 INCHES ABOVE ROOF AS PER NEC 310.15(B)(3)(C) Number of Conductor Conductor Conductor Base Ampacity *Temperature Fill Derated Circuit Min. OCPD EGC EGC EGC Conductor Conduit Strings Material Type Size @ 00°C Factor Factor Ampacity Current (If Required) Material Type Size No Limit CU PV Wire 10 AWG 40A 0.96 1.00 38.40A t 15.00A 20A CU BARE 6 AWG N/A - Free Air JUNCTION BOX TO INVERTER *TEMPERATURE FACTOR IS BASED ON 2% DRY BULB HIGH TEMPERATU'R'E OF 31.40E WITH A OOC TEMPERATURE ADDER THEREFORE RACEWAYS MUST BE AT LEAST 0.75 INCHES ABOVE ROOF AS PER NEC 310. 15(B)(3)(C) "TABLE ASSU MES ON E EGC PER CON DU IT. MI N I MU M ON E EGC IS REQU I RED PE. R I NVERTER PER CON DU IT. Number of Conductor Conductor Conductor Base Ampacity *Temperature Fill Derated Circuit Min. OCPD EGC EGC EGC Temp. Conductor Ampacity Max Derated # of Neutral Ground Ground Conduit Conduit ID From Min. EMT Size Strings Material Type Size @ 00°C Factor Factor Ampacity Current (If Required) Material Type Size Ampacity 1 CU THWN-2 10 AWG 40A 0.96 1.00 38.40A 15.00A 20A CU THWN-2 10 AWG 0.50 in. AC CONDUCTOR SCHEDULE v TITAN TITAN SOLAR PHONE: 1 -855 -SAY -SOLAR WWW.TITANSOLARPOWER.COM PROJECT: 10675 W 47TH AVE MUNICIPALITY: WHEAT RIDGE, CO ZIP CODE: 80033 CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC AUTHOR. EE DATE: 27/APR/21 REV- - E2 - ELECTRICAL CALCULATIONS 04/29/21 DO t vn 52158 Exp. 10/31/21 CPSCO, ELECTRICAL POWER 5 SAFETY CO. AC Circuit 125`?' OCPD Conductor Fill Am bient Temp. Conductor Ampacity Max Derated # of Neutral Ground Ground Conduit Conduit ID From T -C, Phase Vo Itage Current Multiplier (If Present) C3 L erial Type # of CCCs Factor Temp. Factor r Size @ 7 5 ��'C Ampacity Ampacity Neutrals Size Ground Type Size Type Size I SE I NV1 L-, F 17 1') I't 10 240 (V) 12.5 (A) 15. 6 (A) 20 (A) Cu THWN -2 2 1.00 31.4( -C) 0.96 12 AWG 25 (A) 30 (A) 28.8 (A) 1 12 AWG EGC THWN -2 12 AWG E rvI T x.50 (in.) AC Disconnect 1 10 240 (V) 12.5 (A) 15.6 (A) 20 (A) Cu THWN-2 2 1.00 31.4 0.96 12 AWG 25 (A) 30 (A) 28.8 (A) 1 12 AWG EGC THWN-2 12 AWG E N1 T 0.50 (in.) v TITAN TITAN SOLAR PHONE: 1 -855 -SAY -SOLAR WWW.TITANSOLARPOWER.COM PROJECT: 10675 W 47TH AVE MUNICIPALITY: WHEAT RIDGE, CO ZIP CODE: 80033 CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC AUTHOR. EE DATE: 27/APR/21 REV- - E2 - ELECTRICAL CALCULATIONS 04/29/21 DO t vn 52158 Exp. 10/31/21 CPSCO, ELECTRICAL POWER 5 SAFETY CO. WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BY ENERGIZED IN THE OPEN POSITION [NEC 690.13(B)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION WARNING PHOTOVOLTAIC POWER SOURCE [NEC 690.31(D)(2)] PLACE ON ALL JUNCTION BOXES. EXPOSED RACEWAYS EVERY 10' WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE [NEC 705.12(8)(3)(2)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL OR SUB—PANEL) IF APPLICABLE WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. [NEC 690.56(C)(2)] PLACE NO MORE THAN 3.3FT FROM SWITCH SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE S°P PANELSRIC SHOCK HAZARD IN THE ARRAY. [NEC 690.56(C)] PLACE AT MAIN SERVICE PANEL PLACE THIS LABEL WITHIN MAIN SERVICE DISCONNECT (OR ON OUTSIDE DISCONNECT OF OPERABLE WITH COVER CLOSED) CAUTION: SOLAR ELECTRIC SYSTEM CAUTION CONTAINS MULTIPLE POWER SOURCES [NEC 705.12(8)(3)(3)] PLACE THIS LABEL AT [NEC 705.12(C)] PLACE LABEL ON ALL EQUIPMENT CONTAINING P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER (I.E. MAIN PANEL OR SUB—PANEL) IF APPLICABLE TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES NOTES: 1) ALL LABELING USED OUTDOORS MUST BE ENGRAVED METAL, UV STABILIZED ENGRAVED PLASTIC OR OF A MATERIAL SUFFICIENTLY DURABLE TO WITHSTAND THE ENVIRONMENT INVOLVED. VALUES HAND WRITTEN OR IN WRITTEN IN MARKER ARE NOT ACCEPTABLE PER NEC 2020. 2) LABELS USED INDOORS MAY BE MADE OF DURABLE VINYL OR PAPER 3) DO NOT COVER ANY EXISTING MANUFACTURER APPLIED LABELS WITH INSTALLATION SPECIFIC LABELS 4) LABEL COLORS CHOSEN PER NFPA 70 2020 DIRECTION THAT ANSI Z535-2011 BE USED 5) ALL FORMATTING SHALL COMPLY WITH NEC 2020 6) ADDITIONALLY, IT IS HIGHLY RECOMMENDED THAT THE INSTALLER ATTACH A LABEL WITH THE COMPANY NAME AND CONTACT INFORMATION AT THE INVERTER 7) ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(8) T 11 PROJECT: 10675 W 47TH AVE TITAN SOLAR MUNICIPALITY: WHEAT RIDGE CO I TA ti PHONE: 1-855—SAY—SOLAR ZIP CODE: 80033 CLIENT: RAYMOND E BEST L `A�� R P 0 lo, R .TITANSOLARPOWER.COM 3.330 kW DC—STC/3.000 kW—AC [NEC 690.13(B)] ALL AC DISCONNECT SHALL BE LABELED :.D(C PHOTOVOLTAIC DISCONNECT [NEC 690.13(6)] ALL DC DISCONNECT SHALL BE LABELED [NEC 690.54] PLACE LABEL AT "POINT OF INTERCONNECT 1" [NEC 690.53] PLACE AT INVERTER 1 FORMAT 1. MINIMUM 3/8 INCHES LETTER HEIGHT 2. ALL LETTERS SHALL BE CAPITALIZED 3. ARIAL OR SIMILAR FONT (NON—BOLD) RAATPPIAI PHOTOVOLTAIC SYSTEM CONNECTED UTILITY METER SHALL BE LABELED PHOTOVOLTAIC AC DISCONNECT AC DISCONNECT SHALL BE LABELED REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS AUTHOR: EE DATE: 2 7/APR/21 REV: — E3 — WARNING LABELS 04/29/21 � N 52158 Exp. 10/31/2 Aplt. p 0 ELECTRICAL POWER 6 SAFETY CO. P A N E L JUST ER I KA kA :5 r (79UA N 0 9 L E 251- -1 N- $1] MA 101RODUCT 4L $ HIGH TIME $$$ 111*jow NDUSTRY LEADING WARRANTY 1he Titan Solar Panel is manufactured by Silfab Solar ind includes an industry leading 25 -year product tormanshlp and 30 -year perfori-nance warranty. AAXIMUM ENERGY OUTPUT .everaging over 35+ years of worldwide xperience in the solar industry, Silfab is dedicated to uperior manufactu d ng processes and innovations arc has Bifacial and Back Contact technologies, to �nsure our partners, such as Titan Solar have the 3test I n so la r I nnovation. SIO RTH AMERICAN QUALITY 'H'Ifab is the leading automated solar module manufacturer in North America, UtIlicEing rem lum qual i*ty materials and strict quality control rianagement to deliver the highest efficiency, rem lum quality Wmodules- spa BAA / A RRA COM P LIA N T These panels are designed and manufactured to meet Buy Ame- rican Act Con-ipliance The US State Departrnent, US Military and FAA have all utilizi-i-d Silfab panels in their solar Installations. ;0;009 LIGHT AN D DURABLE Engineered to accornmoJate high wind load -conditions for test loads validated up to 4OHO OPa uplift The light -weight frame is -exclusively designed for wlde-ranping racking compatibility and durability 1H QUALITY MATTERS Total autornation c-risixes strict quality -controls during the entire manufacturing process at ISO certified facilitli-'-s ,91 DOM ESTI C SU PPORT I S ERV I CES Our 500t North American team is ready to help Titan Solar v,i n the hearts a nd mi nids of c ustomcers. provid IN custo mer service a nd produc t d elly*--r-y that is di rest, effic le nt a nd I teal iii AESTHETICALLY PLEASING Ad I blas k sl eek design, idea I for high -profil e resident ial or commercial ap pl ications, ;61! PID RESISTANT PIE) Resistant due to advanced cell technology and material s-A_l,;_-<tion In accordance to IEC 62804-1. TITAN SOLAR PHONE: 1-855—SAY—SOLAR WWW.TITANSOLARPOWER.COM T,w+ SIL -370 NX mono FERC STC NOCT Module Rawer (Pmm) WF 370 266 MmirnurTn power vchaae CVprnm) V 37.2 332 Mim i rn u m paws r current Opmut) A 10.0 7.9 Lan circtit vcltap (Voc) V 44.8 407 Short circuit current 099) A 10.6 83 M DdLife OR C i en!y % 20.2 18.2 Mmirnum system vokage (VDC) V Junction Box 1000 Swim ftim rating A Module product yvorkrnanshipwarranty 20 PowerToleranceWF -q-3% Naar umnoct cm&mw STC 1000 W.Wa - AM t - Twqwmburs 2S'C - NXT SWOYSn' 4 AM IS - Mmumi.mi uncw-wiitys 3% -Sum iear Int wcdbr@6m rw(wmc&mv&jk3 from Framh4for IndRjA4. ElociAcji c6ractaistin" vvy by IS% mid paaw 6y+b3%. TwTwatum Caagciant Inc 7"TG,raturia Cwffident Voc Twrparwturs CoAcient Pit SIL -570 NX rnc4no PERC (i - 0" V 3 C 4122 "C n QA T_rr Mug_ 1 (* X_W1 40-N.. Opera tinp temperature -40/+85 *C ir op • u1not It . MIM I a 4 Iff, I All Kor*, A 11 SIL -370 NX mons. PERC Modul-2 wrAight 44-40A Ibs Dirnwaiws (H x L x D.) 72.0 in x 39.4 in X 1.5 in Max i rn u m s u rFa ce I cad (w i n des n <Yow)' 93.5Al2,8 I b�ft"'2 Hail impact resistance o 1 in at 51.6 M-0— 'Calk 66 - S www -PE RC - 5 buster, 6'.25 z 62.25 in Glass 0.Q6 in hilL"rumittmrwm, twTfeniicl, DSM anti -PsAmt" cwting Cab lei and eco nriGctears (rwfw im irdulevan ma rPA) 47.2 in, s 0.22 in, MC4fiwn Stul:Ai Backihoa Hth durab3hy, supericr!ydmsus and.Wrwistmnca, mdi-1 ar dielectric film, fluorirw4w PV backime Frame Anodized Alurninurn (136ck) clodes 3 clo,.6-30SQ045T (45V rmm CC blockingwAVe, JOA rrmx ;cc"wd rs-ctiFood curmW, Junction Box U L 3730 Cortif6d, I EC 62790 CartAed, I P67 rated Werrenties SIL- 370 NX mono FERC Module product yvorkrnanshipwarranty 25 )roars`' Uroaar power pwforToncro guarantoe Product Factory 30 years k 97.1% and l'year 2:91.6% and 1T' year 1 2:85.1% and 5" your 2t 62 A% and 30P" aw SIL -370 KX mom FERC ULC ORD C1703, U L1703, CEC listrwde", U L 61215-11-1 Af- 2, U L 61730 -If -21 IEC 612154-114-2l". I EC 61730-111-2wo. CSA C22-24617304-2- I K 62716 Aim nTania Cami6n; IEG617DI:2011 SaltMist Carrion gmtfig U LRm Rating TyFe 2 15090UI:2015 All statas;x:epri C;difomij Calftnia Moldas Per Nlar 26 Jul od u krs ke Pal I in: 26 Pa I 4c s Par Truck: 34 Pzi I lx s Pear Truk: 32 M oJ J a s N r Truck: 94 Modulps Rw Truck; 8,32 *A Wa rni rq. Pka tl'thia Swk;cf wd Inm lat ion Mzxai fur rn o unE rg zpQc f d cm an d LQfcx,& [wrpzl h g, irua I irg a nd op;raicing modulos. '12 yow %x i rad" to 2 5 yea rs sm b.k a to maim r6on an d corn- ' o ns o Lrd in ad u rvl r 0Wj rr3 n V n wwwsiffik-sd mr. ccm ' %CoH fi cido n and C CC I rd rq in pvqw. PAN files giiinorawd from 3rd pray p4diccmwr.a dm are w a i la bb for &-mri old am: sib arae om1&nwrJoads, o Silfab WLAX MOM PROJECT: 10675 W 47TH AVE MUNICIPALITY: WHEAT RIDGE, CO ZIP CODE: 80033 CLIENT: RAYMOND E BEST 3.330 kW DC—STC/3.000 kW—AC rrta n Solar Powror 525W Bzolino Rd Mcm, Al 85210 Td 855 SAY -'SCS LA R rrta n s a"" 0 L COM i n FbaSt it wad a rF>7&Gc Silfk Sd;r Inc. 2AO C owt n ey W. Drive East M i&si sa u ga 0 N L5T 2Y3 Cz-" TQ1 fl 905-255r2W Fax *19-05-696-02,G i n FW @ s i Fzbsca.2r.--_ cm wwwz I Fa be c4. c cm Silf2b Sd2r Inc. WO Cornwal Aefo Wli-tg+um WA 98225 USA Td 1•1360-569-4793 AUTHOR. EE DATE: 27/APR/21 REV- — - 114 F C" at N 40 � S of 39 11, PsEerr 32 3.1, 1 1AX or ri A 04/29/21 a 14 bA Al — PANEL SPECIFICATIONS Vill 52158 Exp. 10/31/ 1 WAL CPSCO, ELECTRICAL POWER 5 SAFETY CO. 0 (;rossRall LILI—X & IvIechanic-ml Propeia Lies Material Ultimate Tensile Strength Yield Strength Weight Finish Se(Ai c i� Iii~ �� L 5X Sy A (-Section) 6,000 Series Aluminum 37.7 Iasi (260 MPa) 34.8 ks (240 MPa) 0.47 1 bs/ft (0.699 kg/m) Mill or Dark Anodized 0.1490 In 3 (0.3785 CM3) 0.1450 in3l(0.36,83 CM3) 0.4050 in' (1.0287 CM2) Technical data Roof Type Material Flexibility PV Modules Module Orientation Roof Attachment Structural Validity 39 I 4216.40 1.54 166 Warranty Dimensions in [mm] Inches Notes: Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-16 UL2703 Listed System for Fire and Bonding V V CrossRail System years Composition shingle, tile, standing seam High corrosion resistance stainless steel and high grade aluminum Modular construction, suitable for any system size, height adjustable For all common module types Portrait and landscape Screw connection into, rafter IBC compiiant,, stamped engineering letters available for all solar states 25 years F C" of N k MAff 6t)ak4A1 s.�o 2ou Or 1)0 ............... ww�ni.evierest-sclarsystemq.ccni www,everest-salarsystemsxcni 04/29/21 � N 52158 TITAN SOLAR PROJECT: 10675 W 47TH AVE AUTHOR: A2 -RACKING SPECIFICATIONS 4 1 MUNICIPALITY: WHEAT RIDGE, CO I I 0 T I T A PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 Exp. 10/31/21 WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC REV- -Cf�SCO, ELECTRICAL POWER 5 SAFETY CO. SPEC SHEET Part # Box Quantity 17664 5.25" Bolts (10) 17666 3"' Microflashing(D (10); 5.25" Bolts (10) 17667SS 3" MicroflashingOO (25); 5.25" Bolts (25); L -Foot (25); 5/16" Serrated Hex Flange Nuts (25) Micraflca5hi nock. Part # 17669 5/16$1 x 3" 304 Stainless Steel Compression Washer Black Part# 1765 9 5/16" x 4" 304 Stainless Steel Compression Washer Black 5830 Las Positas Rand, Livermore CA 94551 1 3948 Airway Drive, Rack Hill SC 29732 Phone: (844) 671-6045 1 Fa c: (80-0) 689-7975 75 1 www.quickbolt.com ,►uickBOLT is a division of Quickscrews International Corp. TITA I S O L A R P O W E R TITAN SOLAR PHONE: 1 -855 -SAY -SOLAR WWW.TITANSOLARPOWER.COM PROJECT: 10675 W 47TH AVE MUNICIPALITY: WHEAT RIDGE, CO ZIP CODE: 80033 CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC Part * 17 664 5/16-18 X 5.26, 304 Stainless Steel Removable Hangar !Bolts 0.14" W 5¢-4 "� Part # 17669 5/1611 " 304 Stainless Steel Compression Washer Black Notvral colovtlack 1 )4S S 1 794 S S b LL L 41 -nm I hick � + I - 4 j 4.0 I 4C Custmer Technical requir nt : The limns ions of the hooks ars; in accordance with the €irerings. Surface smooth, without burr. & 2 mm Matertal 304SS mfr. Svlc k?lmwxc ± m rt't Hole durtame kAzz= t 0.5 r -r-1 r r 7 Deft; 2017, 11.28 Aud i, for : r .wdoxw� * 2 mm ,e.. 0.1 n -i m Ajle tali ee 4 1* MM 5830 Las Positos Road, Livermore CA 94551 I 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 1 Fcx: (800) 689-7975 j www,quickbolt.com QuickBOLT is a division of Quickscrews International Corp. AUTHOR: EE DATE: 2 7/APR/21 REV: - A3 - MOUNTING SPECIFICATIONS city of 04/29/21 c`9 E Vn 158 Exp. 10/31/21 ONAL P 0, ELECTRICAL POWER 6 SAFETY CO. /Sin --le Phase Inverter 0 wit HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE300OH-US SE38OM-US SE5000H-US SE600OH-US SE7WH-US SE16I)CAC OUTPUT Med AC ftYmat Qj1put 303 313W 4P 240Y 10 * 24M 75aD 100DO 1U00 0 MY VA W MWn'KJM IK P001IN 0M_ V 3300 4P 205V 5'00 0 206V W Tf amtmw-im Ung mvidW 10000 0 zw MammiLm AC Pbwff ouipa 30DO 3800 0 24 -JV D'@ 6WD,@ 24(N 760D 100co 114M 0 24av VA 380 400 3300 4P 2M 1 50 CC Q 2CGV 115 W 165 20 27 3- Adc AC Outpts %tkAge k4mANIbm-Max 9 133 27 Addle stonccurrMoit VIC Q11 - 240 - 2K Ade 0 AC Oulptl %tKage lmvmm-Mft� &33 Iu se M my .01 Wiftftm kse-r sef E f IF 992 00 - 2W- 2M CIC Migh*J Miemy 99 99,0 240Y 0 AS 2M AC F*quaxy tin -a.4 59-3 - 60 - 60-50 Hit MaIOMLM CCrbftxxA Wput12.5 25 32 Q J7.5 A CLyreft 92'm supmlw coftv"UnkAim Intert&es IRSU$, � ZkAft Optcei.*, Cellular (OpWAJ4 Woman CC(th.CXA OLAPut hewme Grade D" ANSI C1220 15 24 4&5► CurretV 02COV STANDARD COMPLIANCE SAA&V My ktorftu hg. kd&o_; P*Awtb, Cntydry Cnnlojr,, - 1UE1547. Rae 2t MA 14 Thmdtddi 4 INPUT Madnxm DC Pt W 024W 465ta 59M 7750 &M V" 155M 17650 W MWn'KJM IK P001IN 0M_ V Sim 7M - IWO W Tf amtmw-im Ung mvidW Ves M410iman hvtA %titage 480 %dC NCM rid OC InpA "age 380 400 M"mum hW CurreM 0240VO &5 115 W 165 20 27 3- Adc Munn iqW Current 020OW 9 133 27 Addle stonccurrMoit 45 Ade 0 Gound-Fault hoWhm (Wed ion &33 Iu se M my Wiftftm kse-r sef E f IF 992 CIC Migh*J Miemy 99 99,0 240Y 0 AS 2M 76 No H&ft Power Conmongtioa 2.5 W AODFFMAL FEATURES supmlw coftv"UnkAim Intert&es IRSU$, � ZkAft Optcei.*, Cellular (OpWAJ4 hewme Grade D" ANSI C1220 optknw P.WW ShUtdoYm 2017 6900? &Aonvok RApid Shuukwn upon AC Gnd Dsconed STANDARD COMPLIANCE SAA&V U111.1741, UL1741 SA, M1669& CSA C22Z CoWien AFC1 aacwdinq to UL M-07 GO Con rt!ir- tic- 0 SIS'A&ds 1UE1547. Rae 2t MA 14 4 _Emizicm FCC W 15 CLzs I INSTALLATION SPIECIRCATIONS AC WpU C"jt Sge f AVOIG RWqe 3f4* rn n i -P u fn / 14-6 A%G 3/4" worimum, A" AMG DC InpLi CafdAt Stm 18 of StOgs d AWG Ro%ge 3/4m rninkvum / 1-2 2 f U-6 AM 3/40 minnium / 1-3 wings 11" AWG Doweoiom with S*4y 5* Ott h 17.7 x 14-6 x 6.11 / 450 x 370 x 174 2,13 x 14.6 x 7"31540 x 370 x 195 in Vkiot wAth $Sky Svs*% 22/10 1 25.1 / M 262 M M 117.6 lb 114 �Nkw -C 25 'C50 dRA CON"_ katafal C-brW604% ow"Ag *fflPfAt" RNW -40, to +M / -25 to +W* (-40 / -KC op"10 If*( pmection R&nq Int M& 4X onvertef valh Safe -y. Swkchl 4 F<r c1hw ural w"i O&K* cwW SdwEd5p affon 0 A Npier c~ mace rray be u 2@4 the Vw&nv W11 VW Its irput aAwt W its vA6ds OW 0 Phrimus 9rade i nvwtor " st MIN #350 NU W) For pcmw do -rwriq Wkrmdkn ref v Ux h*Wtw 1Wx2rnLPCff NJ -410 VWdM P'N' St WN AJ90CCMA" goo crmpodorW fiedw aryls c0!d9m1*p Ire A] cd . truhmarks nommed boron o baden a its V rho, rrarprcrirr ax rom zM QM*VW*~ Sao" so ft chinp W&CM MCI= RoHS Single PhIt ase nvererz with HD -Wave Technology< M for North America X_ SE300aH US SE3800H-US / SESOOOH US / SE6000H US SE7600H-US SE10000H-US SE11400H-US "i m solar =*F;a V 1 4Wx W Optimized installation with HD -Wave technology I Specifically designed to work with I Extremely small power optimizers I Record-breaking efficiency I Built-in module -level monitoring I Fixed voltage inverter for longer strings I Outdoor and indocr installation I Integrated arc fault protection and rapid shutdcwn for/ Optional: Revenue grade data, ANSI C12.20 NEC 2014 and 2017, per arb'de 690.11 and 690.12 Class 0.5 (0.5% accuracy) I UL1741 SA certified, for CP4JC Rule 21 gn'd compliance solaredge.com PROJECT: 10675 W 47TH AVE TITAN SOLAR MUNICIPALITY: WHEAT RIDGE, CO T I T A Iq PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 S 0 L A R P 0 W E R VVWW. TITAN SO LARPOWE R. COM CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC solar - • • err AUTHOR: EE A4 - INVERTER SPECIFICATIONS DATE: 27/APR/21 REV- - 04/29/21 VM 52158 Exp. 10/31/21 NA CPSCO, Power Optimizes• For North America P320 / P340 / P370 / P400 / P405 / P505 ,IT UW UW cc %WNWR 4M— WS W -0L AW Wx ru-n hpLd 'Ic NX at kmVIst XhAW 48 so 1.X0A UR WIC NOPTOW-Arg pa 8 - 60 8-90 U -S - M U's - 83 Mmer-wn Shon Circa, 11 lal 1A Adc M=rLn DC UVLA Cumin 133S i fa 17-S A& Wax MWIn EAM" cy 99 S VM#lwd I ffrmrxy 90.6 % _UWr%t*XP C409my I OU TP UT DU RING 0KRATION (POWER 0 PTIMIZ E R CONNECTED TO OP E RA_n N G SOLA RED> DMRTER) Kum r-wnOu W. C.6f —1—AdIc KAMMY" CX9PA %btve _T as OUTPUT DU RING STANDBY POWER OMMIZER DISCONNEICrIED FROM SOLAREDGE TWEKMR OR SQWtEEGE INVERTER OFF) m.it Win. S.ffriy Cu STANDARD COMPILLANCE F(L Par: IS Cats IL IMM -&A", I K.61 OM. -f. I SAV JEW 109-1 JcL= 3 wkrA LL17-91. INSTAUATM SPMFICAnOM Max n- -n Mmad *ftm CIonva.pbe rramn Al SolarEcige Sln Ps and nvw Ptow rwun Cwrien gm JYJ x L v K 12A T Mr 36 1.'�s ls� I SO 18r15:: v 28 5 it 5.97 x 1.1 S x 5.97 x 14.2 5 x S 47 x 1.96 Ve X M it S9 1, 5.97 x 2-32 rrrn I in Wo4v (rdAng cabir-4 SO/ L4 75011.7 945/19 10612.3 car ilb In FA Cm-mictme WCC Q Ot#Ln Wray TXv / Came= oautk knkftd MCA ch -W, Wrr OL95 10 T 9 m/ ft Inpt 'mV rt% L,r--qth a 16 / 051- M/ ft Upwalrig-kTrPrn.um Rpr -V - ISS/ -0- *1AS 'C / T kdxror Hirri3m, 0-100 RAW src poww of d* fto&Ak WWJ& of up to - 5% P&*Mf XlWaftit Au"d Nsc ZD17 V4.9'I MAC rpa v -JW" t* rWA (V"* ther- WY pa" C&JA3 S06VI dq& P 3 M NIX 1 Kos 0; Larigth C-17new- Oph rram) S 700 (CM wth muri'm Pcwv. per Stmg SM -LAS- A 11.400- MA 1275IN W Parte! Sinings d b1k4m . migft yes or "." MKftdWM F11 k k na Aftad W mk P40VKM aM FM Q*34P3 7% MW ei cr* sir IN PA " vAlh wAQft *wn 30apknI 4caL ra mm W &Arry wil be A&,* Va 3W mqan� Fa SMMM&U4 29A k k dowad an eaUl up, @o66WW po sing Wwn 3 iur+.I wqvawd tu en r t3 or pw urk to SULAIRM wtdn ** waakuum V&aw Wkwa%to bwwaoh do " a up a* IAOM in to S ,E-- -m- 0'6jU4fi6M IVISSMas1 I k A&Md oaf sip 10 1"WN rw .71 'rg witwit 3 ia, tp� a- j,v*awJ to ft iwenw :3 wirpit aW W SMSKAWI OM aw WAM *a f%ftaLft dfbowina homon d%* wivp a up in ),DMW Power Optimizer For North America P320/P340/P370/P400/P405/P505 25 YEM !i,4��lllll���'N r PV power optimization at the module -level I Specificallyde.signedto work with SolarEdge i r ve rte r,.,, I Up to 25% more energy I Superior efficiency (9g.5L%) Mitigates all type -s of module mismatch losses, from manufacturing tolerance to partial shading I Flexible system design for maximum space utilization ? Fat in-stallaton with a single bolt N ;a I Next generation maintenance with module - level monitoring I Meets NEC requirements for arc fault protection (AFCD and Photovoltaic Rapid Shutdown System (PVRSS) Module -level voltage shutdown for installer and firefighter --safety C" of S./o 202/ Jolared-C.12.com r.. 04/29/21 solarmR MOOM—wa-M, www�=I Iry th" amV&-nn ammm DIIIIIIIw NW kood to dm %wrInd yes.CE RcHS A VM 52158 ITITAN SOLAR PROJECT: 10675 W 47TH AVE AUTHOR: A5 OPTIMIZER SPECIFICATIONS MUNICIPALITY: WHEAT RIDGE, CO I I Exp. 10/31/21 NAL T I T A Iq PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 S 0 A R P 0 WE R WWW. TITAN SO LARPOWE R. COM CLIENT: RAYMOND E BEST REV- P 0' 1 1 3.330 kW DC-STC/3.000 kW -AC I ELECTRICAL POWER 6 SAFETY CO. LOCATION OF NEAREST URGENT CARE FACILITY NAME: ADDRESS: PHONE NUMBER: NOTES: • INSTALLER SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME *INSTALLERS SHALL UPDATE NAME, ADDRESS, AND PHONE NUMBER OF NEAREST URGENT CARE FACILITY RELATIVE TO THE JOB SITE BEFORE STARTING WORK. PERSONS COVERED BY THIS JOB SAFETY PLAN INJURED AT WORK TODAY? INITIAL YES OR NO PRINT NAME INITIAL YES NO UNDERGROUND DIG REQUIRED? YES PERMIT # T A Iq O L t R P 0 ill E TITAN SOLAR PHONE: 1 -855 -SAY -SOLAR WWW.TITANSOLARPOWER.COM PROJECT: 10675 W 47TH AVE MUNICIPALITY: WHEAT RIDGE, CO ZIP CODE: 80033 CLIENT: RAYMOND E BEST 3.330 kW DC-STC/3.000 kW -AC AUTHOR: EE DATE: 2 7/APR/21 REV: - A6 - SAFETY PLAN 04/29/21 � N 52158 Exp. 10/31/21 P 0 ELECTRICAL POWER 6 SAFETY CO. �..— W— 4, � AO RE: 10675 W 47th Ave, Wheat Ridge, CO 80033, USA To Whom It May Concern, EP CO DATE: April 26, 2021 As per your request, we have conducted a structural assessment of the building at the above address. PV solar panels are proposed to be installed on roof areas as shown in the submitted plans. The panels are clamped to rails which are attached to the roof with a lagged mounting system. The PV system (PV modules, racking, mounting hardware, etc.) shall be installed according to the manufacturer's approved installation specifications. The Engineer of Record and Exactus Energy assume no responsibility for misuse or improper installation. It was found that the roof structures satisfactorily meet the applicable standards included in the IBC 2018, I RC 2018 and I EBC 2018 as well as the design criteria shown below: Design Criteria: Wind speed = 105 mph Ground snow load = 30 psf Roof snow load = 23.1 psf Roof dead load = 9 psf Solar system dead load = 3 psf Overall, the roof area is structurally adequate to support the PV alteration as per 2018 IEBC Sections 502.4 and 502.5. This letter was completed in accordance to recognized structural analysis standards, professional engineering experience, and judgement. Prior to installation, the on-site contractor must notify Exactus Energy if there are any discrepancies, or damages to the structural members, that was not addressed in the plan set. If you have any further questions, please do not hesitate to contact me. Acknowledged by: 1100C" of MWAX1 04/29/21 Pot /0j" 0 2J Digitally signed by David C. Hernandez "� 52158 David C. Hernandez Date: 2021.04.2919:28:52-04:00 Exp. 10/31 /2 1QNAt P 0 ELECTRICAL POWER 6 SAFETY CO. ELECTRICAL POWER 6 SAFETY CO. EP COOperating in: USA. Canada. Mexico P: 651.433.4550 Office Locations: MN - FL - NY - OH - TX - CA E: service@epsco.co 1* � � i City of Wheat Ridge Residential Solar PERMIT - 202100860 PERMIT NO: 202100860 ISSUED: 05/10/2021 JOB ADDRESS: 10675 W 47th Ave EXPIRES: 05/10/2022 JOB DESCRIPTION: Installation of a Roof -mounted PV solar system. (9) modules 3.330 kW DC *** CONTACTS *** OWNER (303)424-9385 HOOD LEASON D SUB (480)226-6769 DAVID WILLIAMSON 202247 TITAN SOLAR POWER CO *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 17,982.00 FEES Total Valuation 0.00 Residential Solar 500.00 ** TOTAL ** 500.00 *** COMMENTS *** *** CONDITIONS *** A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 05/10/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. IV ' A IV City of Wheat Ridge _`'`9r '`9Residential Roofing PERMIT - 201702229 PERMIT NO: 201702229 ISSUED: 06/20/2017 JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ GLENS CORNING STORM CLASS 4 LAMINATE ASPHALT SHINGLES - 26 SQ. is byy, m t signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that i am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with tfiis ermn. i further attest that i am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes. ordinances, regulations, policies and procedures. ?. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the ChiefI3 IIding Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Offlccial and is not guaranteed. 4, No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and fnspeetion Services Division. 6. The issuance or grantin ermit sh'All t b its . ued to be a permit for, or an approval of, any violation of any provision of any applicable code or an d' -regul t 1 }urisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequest(:a,,�ei.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. . r City of Wheat Ridge Residential Roofing PERMIT - 201702229 PERMIT NO: 201702229 ISSUED: 06/20/2017 JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT SHINGLES - 26 SQ. *** CONTACTS *** OWNER (303)887-0371 HOOD BEVERLY GC (303)781-8185 Corey Largen 017636 A to Z Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 I *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00 FEES Total Valuation 0.00 Use Tax 201.60 Permit Fee 204.30 ** TOTAL ** 405.90 *** COMMENTS *** *** CONDITIONS *** EffectivE December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A'/: -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturerdt-'s installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of"final inspection. ' City of Wheat Ridge Residential Roofing PERMIT - 201702229 PERMIT .NO: 201702229 ISSUED: 06/20/2017 JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT SHINGLES - 26 SQ. *** CONTACTS *** OWNER (303)887-0371 HOOD BEVERLY GC (303)781-8185 Corey Largen 017636 A to Z Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00 Total Valuation FEES0.00 Use Tax 201.60 Permit Fee 204.30 ** TOTAL ** 405.90 *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturera€'Ms installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval frcm the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of"final inspection. Avc INSPECTION RECORD NSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/forms.aspx?fid=79 INSPECTION REQUEST LINE: (303) 234-5933 Occupa,_ 11 e Inspections will not be performed unless this card is posted on the project site. Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.** Inspector Must Sign ALL Spaces pertinent to this project Inspector Comments Foundation Inspections Date Initials Pier Concrete Encased Ground (CEG) Foundation / P.E. Letter Do Not Pour Concrete Prior 10 H provai vi ii nt; mwvvw n 15p.c�.�•v• •-� Underground/Slab Inspections Date Inspector Comments Initials Electrical Mid -Roof r Sewer Service Lath / Wall Tie Plumbing UO Not Gover unser rvunu Rough Inspections v' ow"_'vv"el —,a.. -•�•• Date Inspector Initials - �� - - - Comments Wall Sheathing Mid -Roof r Lath / Wall Tie Rough Electric " Rough Plumbing/Gas Line Rough Mechanical Rough Framing Rough Grading Insulation _ Drywall Screw / Nail Date Inspector Final Inspections Initials Comments Landscapi ig & Parking / Planning Dept. Inspections from these entities should be requested one week in advance. For landscaping and parking inspections call 303-235-2846. For ROW and drainage inspections call 303-235-2861. For fire inspections contact the Fire Protection District for your project. ROW &Drainage /Public Works Dept. Floodplain Inspection (if applicable) Fire Inspection / Fire Protection Dist. Final Electrical Final Plumbing Final Mechanical Roof -1 Final Window/Doors L Final Building NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy. s.-.-... ♦4..-. Gro n;i +,irt and alPCtrinAl low vnit2n P. "For how voltage permits - riease uu suic uiai 1Vuy by the Building Division. Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued Protect This Card From The Weather A i CITY OF WHEAT RIDGE __:��Buildin4-inspection DiVMion (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 75 af-� Permit Number: ❑ No one available for inspection.: -Time D �.AM/PMS Re -Inspection required: Yeso When corrections have been made, call for re -inspection at 303-234-5933 I /I ; Date: (0/0 Inspector: )O1-�l' r DO NOT REMOVE THIS NOTICE A 4' City of Wheat Ridge Residential Roofing PERMIT - 201702229 PERMIT NO: 201702229 ISSUED: 06/20/2017 JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT SHINGLES - 26 SQ. *** CONTACTS *** OWNER (303)887-0371 HOOD BEVERLY GC (303)781-8185 Corey Largen 017636 A to Z Roofing *** PARCEL,INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00 FEES Total Valuation 0.00 Use Tax 201.60 Permit Fee 204.30 ** TOTAL ** 405.90 - *** COMMENTS *** *** CONDITIONS *** Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) requires an approved inspection prior to installation of ANY roof coverings and is require on the entire roof when spaced or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer&ems installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer&#39;s technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201702229 PERMIT NO: 201702229 ISSUED: 06/20/2017 JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018 JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT SHINGLES - 26 SQ. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable wilding codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this perit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Budding Official and may be subject to a fee equal to one-half of the originalermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. Kimberly Cook From: no-reply@ci.wheatridge.co.us Sent: Monday, June 12, 2017 12:36 PM To: Permits CommDev Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application ("I This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT 1 IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. Permits are currently being processed within 3-5 business days, subject to change based on volume. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number Property Owner Email Address Do you have a signed contract to reroof this property? It will need to be provided at the time of permit pick-up. 10675 W 47th Ave Beverly Hood 303-887-0371 Field not completed. Yes CONTRACTOR INFORMATION Contractor Name A to Z Roofing Contractor's License 017636 Number (for the City of Wheat Ridge) Contractor Phone 303-781-8185 Number Contractor Email Address info@denverroofers.com (permit pick-up instructions will be sent to this email) Retype Contractor Email info@denverroofers.com Address DESCRIPTION OF WORK Is this application for a Yes new permit for a residential roof? Are you re -decking the No roof? Description of Roofing Owens Corning STORM Class 4 laminate Material Select Type of Material: Asphalt If "Other" is selected Field not completed. above, describe here: How many squares of the 26 material selected above? Does any portion of the property include a flat roof? If yes, how many squares on the flat roof? No Field not completed. TOTAL SQUARES of all 26 roofing material for this project 2 Provide additional detail here on the description of work. (Is this for a house or garage? What is the roof pitch? Etc) Project Value (contract value or cost of ALL materials and labor) 4:12, 1 story, ice barrier and new drip metal •M SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this Yes application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have been Yes authorized by the legal owner of the property to submit this application and to perform the work described above. Name of Applicant D. Corey Largen Email not displaying correctly? View it in your browser. 3 Jun 11 1709:23p A to Z Roofing Jimmy Read pR0 OSAL SUBM17TED T4 BIL LENG ADDRESSS� 9TY, STATE AVD ZPP CODE a ■EXISTI G TYPE OF ROOF: y ■INST.ALL OR REPLACE WITH: r.ti ■COLOR OF SHINGLE: ■MANUFACTURER'S LIMITED WAR •EXISTING NUMBER OF LAYERS: ■ROOF PITCH: Z ■ SECTIONS LESS THAN 4/12: 'INSTALL DECKING: 7/16" OSB INSTALL FELT: 15# ■LNSIALL ICE & WATER SHIELD: YES NO SQ FT _.- ,IME TAL EDGE: 2x2 RAKES 2X4 (120°) EAVES COLOR:! ■ VALLEY TYPE: OPEN -REPLACE PLUNIBING JACKS;� YES NO :A RIDGEVENT (LF): J ' Li AR GUARANTEE ON LABOR ■ G rIZED NAILS, 6 PER SHINGLE r ."GUTTERS CLEANED OF ROOFINGDEBRIS ■A TO Z ROOFING TO FURNISH ALL MATERIAL ANP LABOR a CLEAN UP AND HAUL OFF ALL TRASH FROM ROOF 3038348398 p.4 - . PREFERRED Co Lon.suU Hoorr.'c Also r:tnTlU r: A''ARTMENT ASS.^,ry IATp4 CQNTUCiOR h 1 t f 4251 S. Natches Ct. Unit K, Englewood, CO 80110 Phone: 303-781-8185 Fax: 303-781-4875 Qrtif t.denverroofers,coin info@denverroofers.com . PRONE Dart 106 LOCATION ADDRLSS CITY, STATE AND ZIP CODE 1 SPECIAL TNSTRUCTIONS Il � LG(,S� �t N — \1 TEAR FF:I N l PLYWOOD -PROTECT LANDSCAPE WHERE NEEDED ,ROLL YARD WITH MAGNETIC ROLLER ■PERNDT FURNISHED BY A TO,Z RO ■ INSURANCE PAPERS PROVIDED: . Nt Under the tens of this contract the workmandtip warranty is no until payr An, 11,,rial Wnrnnty is non-tramrferable unlesa otherwise stated by the nvnnufactm UBC building code requires that lastaners (nails ar staples) MOST penetrate deokine sheeting. A to Z Hoofing is not ressasible for exposed eaves that nails penetrate. is made in full A to 7 Roofing is not responsiht: torr driveways or sidewalks that are damaged from vehicles used in nornvl roo ring procedure. An access fee can be laid by customer to insure heavy>•ehicles will not drive on concrete. orthickness of A to Z Roofing is not responsible for mold or mildew. Replacement ofdeteriorated or space decking„ facia boares, ventilators, flashing orother =wrials, unless otherwise stated in this contract, arc not included and will he charged as an "Ira ons time ani tenterlal basis. We Propose to furnish all materials and labor complell ed in accordance with the specifications below for the initial sum of: REPLACEMENT COST: $ per insurance proceeds plus any supplements that may apply to your claim. Upon approval cf your claim, A TO Z RO FIN will file for any and all supplements which may includo building code ilems, unforeacen items and missed or omitted items on the insurance scope provided to you by your insurance company. Those items will be paid per your policy provisions and will become part ofthis contract as if contained herein. ATO Z ROOFING will negotiate a fair and equitable settlement ag:eeable by both your insurance company and A TO Z ROOFING based on competitive market rales for labor & materials with na additional cost to vary except for your deductible and any upgrades oradditiona I work authorized by you that are not part ofyour approved insurance claim. Should your insurance company denya full roof replacement, you will not be obligved to this contract and may enter into an acceptable repair agreement with A TO Z ROOFING. ACCE TANCE Or PROPOSAL— This proposal bcw=E o lees] binning contract 72 ours Earn date of acceptance- 1 'Jz% per month interest will be added an to a:] accounts 30 days past cne In addition, cost, and reasonable attorney's fee for collections may be charged on any account past dueowa 0 days_ Payment will bemade as outlined above. Failure to pay can constitute mechanics tient filed against propery, Cancellation ofthe contract may be achieved by paying q cancellation fee in the acne ant of5F'a of the contract price. All returned checks are subject to a returned check charge foe. {{+ Customer is msponsihte for payment as aolliaed in this cc, and payme■1 to q to ZRoofing is not rontingent upon government irnputirm and !or payment from his or her insuranrc company, A TO Z ROOFING is owned and operated by 2 IIA� INC., a registered Colorado Corporation. All proposals are subject to approval by Management. Customer agrees that he or she has read, understood and agreed to A terms and conditions set forth on the back of this contract d omerwpp jai Date Note: ' proposa be yhdrawn by us if not accepted within days -t r A Repress aiiv .Approval Dale A to 7 Roofing.Wnagement Approval Dale 30/ION SIH13AOW3tl ION 00 :aoloadsul if ,1 :a}aa gE g ;e uoiloadsui-aa aol ileo `apew ueaq aneq suot;oaraoo uagM. o SOA :paainbaa uoiloadsul-aU WdV /, auail :uoiloadsui aol algaIiLIna auo oN n --HLJ M21 El a �) 0()s::- N.-. blo ee' OL, loe :aagwnN Iivaaad :ssaappV qor Q :adA1 uoi}oadsul 30110N N01103dSNI xeJ 6068-200 (006) • ag1JJ0 5sgz-5sz (000) mull uo►.loadsul £E69-PEZ (00 uoisinla uolzoodsul 6uippe !� 1 3Jala 1V3HM =10 Alla