HomeMy WebLinkAbout10675 W. 47th AvenueFrom: no-reolv(alci.wheatridae.m. us
To: CommDev Perm is
Subject: Online Form Submittal: Residential Window/Door Replacement Permit Application
Date: Monday, August 2, 2021 12:29:54 PM
Residential Window/Door Replacement Permit Application
This application is exclusively for RESIDENTIAL REPLACEMENT WINDOWS and
DOORS - LIKE FOR LIKE ONLY.
YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM AND
WINDOW/DOOR CUTSHEET (SPEC SHEET) IN ORDER FOR THE PERMIT TO
BE PROCESSED. Your Permit will be emailed to the email address provided
below once it is processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for Yes
replacement window(s)
and/or door(s) like for
like?
PROPERTY INFORMATION
Property Address 10675 W 47th Ave
Property Owner Name Raymond Best
Property Owner Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
Address
Attach City of Wheat
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
720-272-3789
bester2@comcast.net
CONTRACTOR INFORMATION
Contractor Business Champion Window Co of Denver
Name
Contractor's License 020146
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Steve Hemans
Permit
Email not displaying correctly? View it in your browser.
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
Address
Retype Contractor
Email Address
DESCRIPTION OF WORK
What is being replaced
Number of window
and/or doors being
replaced
Location of
window(s)/door(s)
being replaced (for
example, master
bedroom, kitchen,
bathroom, etc):
r`z81LOrcBefi61
shemans@getchampion.com
shemans@getchampion.com
NVA Morel,
3
Livingroom, bedroom
What is the u -value of .28
the window(s)/door(s)?
City of Wheat Ridge
requires the u -value to
be .30 or better on
windows..
Attach copy of Best2.odf
window/door cut sheets
showing sizes and u -
value
Project Value (contract 4097.00
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
From: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: Solar PV Installation
Date: Friday, April 30, 2021 3:37:18 PM
Solar PV Installation
This application is exclusively for Solar PV Installations
YOU MUST ATTACH A VALID ELECTRONIC PAYMENT ORM IN ORDER FOR
THE PERMIT TO BE PROCESSED.
Your Permit will be emailed to the email address provided below once it is
processed.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Is this application for Yes
Solar PV Installation?
PROPERTY INFORMATION
Property Address 10675 W 47th Ave. Wheat Ridge, CO 80033
Property Owner Name Raymond Best
Property Owner Phone 720-272-3789
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email bester2@comcast.net
Address
Attach City of Wheat 10675 CC.Ddf
Ridge Electronic
Payment Form - "DO
NOT ATTACH A
PICTURE OF A
CREDIT CARD"
CONTRACTOR INFORMATION
Contractor Business Titan Solar Power CO
Name
Wheat Ridge 202247
Contractor's License
Number (This is a 5 or
6 digit number for the
City of Wheat Ridge)
Contractor Phone
Number (enter WITH
dashes, eg 303-123-
4567)
Contractor Email
Address
480-237-2375
copermitting@titansolarpower.com
Retype Contractor copermitting@titansolarpower.com
Email Address
DESCRIPTION OF WORK
Scope of Work Installation of a 3.330 kW DC solar system.
KW
3.330
# of Panels 9
Location of Panels
house roof
Structural required
No
Upload engineer letter
10675 W 47th Ave Wheat Ridge CO 80033 SL.Ddf
or pages on 8 1/2" x
11" only
Solar Installation Plan
10675 W 47th Ave Wheat Ridae CO 80033 Plans.odf
Set on 11'x17" only.
Project Value (contract
17982
value or cost of ALL
materials and labor)
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
Person Applying for Erica Ford
Permit
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Email not displaying correctly? View it in your browser.
RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM
v TITAN
.. R P O W E R
1-855—SAY—SOLAR
525 W BASELINE ROAD
MESA, AZ 85210
EC.0101592
Digitally signed by David C. Hernandez
David C. Hernandez Date: 2021.04.29 19:31:16 -04:00
04,29,21
rr
52158 �
Exp. 10/31 /21 '6.0 U�N 7.
1C 1-0 0
PFW-
1�P 0,
Approval Notes. tLECTRICAL POWER & SAFETY CO.
1) PN array system to have grounding system installed per Part III of
Article 250 per 2020 NEC Article 690.47(A).
2) If UFER ground in not available provide or verify supplemental
ground rods per 2020 NEC Article 250.53(A)(3).
3) Cold & Hot Water & Natural Gas bonding per 2020 PJEC Article 250.104(A)(B)
Eldorado 4
Li- NORIrk
Crescent Springs \\, 4
WESTAMIhL TEq
T� r��. Broo, infield- I'
Rocky Flats
Coal Creek National NORTH CFNTRAI 1 i
Wildlife wEsrMINSTER•
� Nsxalhglenn
Refuge
TMIIMSTEAi",
: �� f=ederal Thornton _
Heights
Derbyi�
White Westminster Mf
'#3
Ranch Park• ak.1"'.1" ., A
4
` iy1 RaLS10N VALLLY 4s Twin Les Na'
a� ._� Cornrrieree
_do CRY
North TablI, 10675 W 471h l�
Mounlain Park Ave, Wheat Ridge, PQ... N1 -i I .
'Test Trailhead �
I�IiI��Gf.�l'�ip. �� y • � � --
-niennial Golders 'li 1�I oenver Zoo
/ � ;'l.0D
me Pc�fiC APPLE1�f4R
I. Trailhead Clear Greek!% V ---------- Denver ---- — ------
10, ---- -
'lest Pleaser,l -
anb`0n Pc7fl{ hfle'u4 C .". -CENTRAL
Genesee Park
William F Lakewood lendale
-�� i layderl Greer,
Genesee a =
Mountain Park
- SOUTH
Kittredge , •
Englewood �
„e
�l�rg?�ET'I I�IARST4AIY1 Mar'' Gherr
Ro
10675 W 47TH AVE
WHEAT RIDGE, CO 8001L L
1*644
3.330 kW DC -STC / 3.000 kW -AC Wli6atp, `"Y °`
27/APR/21
�Mdge
APPROVED
ReviewQd f r Code omod
�.pliance
1=t
Plans Examiner Date
�. Yid of rmit: ass to f a po Of pkns spec*owft
anct computations sham not be a perrnlrtir, or an approval Of ony ve010oon to
any of the proviskm cf the IL utdding rode or of ajt City ordinanceq. permNs
_ preAmng to gw outAo ity to woka or cancel the pwosimns of fft.
boom
cis or'o+thtr" onmof the City shafi root he what
SYSTEM SPECIFICATIONS
SYSTEM SIZE: 3.330 kW
MODULE: SILFAB SIL -370 NX
NUMBER OF PANELS: 9
INVERTER: SE3000H—US (240V)
OPTIMIZER: P370
RACKING SYSTEM: EVEREST CROSSRAIL 44X
AHJ: WHEAT RIDGE, CO
UTILITY: XCEL ENERGY — CO
GOVERNING CODE:
IBC 2018
IRC 2018
IFC 2018
NEC 2020
EXACTUS ENERGY
NEW AGE ENGINEERING
+1 833 392 2887
208-888 DUPONT STREET
TORONTO, ON
SHEET INDEX
C1 — COVER PAGE
N1 — GENERAL NOTES
S1 — SITE PLAN
S2 — PANEL LAYOUT
S3 — STRUCTURAL DETAIL
E1 — LINE DIAGRAM
E2 — ELECTRICAL CALCULATIONS
E3 — WARNING LABELS
Al — PANEL SPECIFICATIONS
A2 — RACKING SPECIFICATIONS
A3 — MOUNTING SPECIFICATIONS
A4 — INVERTER SPECIFICATIONS
A5 — OPTIMIZER SPECIFICATIONS
A6 — SAFETY PLAN
C1 — COVER PAGE
GENERALNOTES:
THE INSTALLATION OF PV SYSTEM SHALL BE IN ACCORDANCE WITH THE MOST R EC EN T NATION AL ELECTR IC
AND 13U ILIDIN G C OD ES AND STAND AR DS. AS AMENDED BY JU RIS IGTION
• PV SYSTEMS SHALL BE PERMITTED TO SU PPLY A BUILDING OR OTHER STRU CTUR E IN ADD ITION TO ANY
ETHER E LE C TR ICAL. S UP P L Y $Y ST EMI(S) [NEG 0 90 A(A)]
a THE INSTALLA110N OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTOMO14NEC1ION SMALL BE
PERFOR NED ONLY BY QUAUFIED PERSONS [NEG 6X4(Gj]
• lE}ClSTlNG PLUMBIN G VENTS, SKYLIGHTS, EXHAUST OUTLETS, VEN1ILA_n0NS IN TAKE AIR CIPENINGS
SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM.
■ INVERTERS,, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AD
PH 070',)OLTAIC MOD ULES, SOUR CE -CII GUIT C OME INERS, AND C HA GE C ON TROLLERS IN TENDED FOR
USE IN FV SYSTEMS SH ALL BE L STED OR FIELD LABELED FOR THE FV APP LICATION [N EC 690.4 (E)]
ALL OUTDOOR ECAJIPSIT SH ALL BE NEMA 311 RATED (OR BETTER), INC LUD IN ALL ROOF MCU N7ED
TRANSITION BOXES AND SWITCHES.
■ ALL E QU IP ME N7 S HALL BE PIR CP E RLQ" GR 04JN DED AN D DO N 10 ED IN AG CORD AN CE M TH N EC AIR TIC LE 2 50.
SYSTEM GR OU NO IVIG SHALL BE IN AS CORDANCE WITH NEC 690.41
EQUIPMEN T GROUN DING CON DU TORS SMALLER THAN 6AArG SHALL COMPLY WITH NEC 250.1120�C
■ ALL PV SYSTEM D C GIRD LINT AND IN VER TER OUTPUT COND U C TO R S AND EQU IPIVEN T SHALL 13E
PIR OT ES TED AG AIN ST OVERC URR ENT UN LESS STATED OTHERAF ISE IN NEC 690.9(A)
OVERS URR EN T DE VIC ES USED IN PV SYSTEM DC C R SUITS SHALL BE L ISTED FOR USE IN FpV SYSTEMS
[NEC 690-9(B)]
PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE ARAPID SHUTE0WN FUNCTICMN 1N
ACC ORDA.NC E WITH NEC 090-12
D 13C ONNECTING MEANS SHALL BE LOCATED IN A AS IBLE, READ ILY ACCESSIBLE LOCATION ONEG
690. 13(A:J]
ALL W IR ING METHOD S SHALL BE IN ACC ORD ASIC E WITH NEC 090-31
CONN EC TORS SH ALL COMPLY WITH NEC 090,33
ALL GROU NDED C ONDU C70R SHALL COMPLY WITH NEC 200-6
PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER
SOU RCE(S) A T ANY D ISTRIBUTION EQU IPIVENT ON TH E FREMItSES SH ALL WET THE FO 0 [NEG
705-12]:
1) EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED GIR GUIT BREAKER OR FUSIBLE
DISCONNECTING MEANS. [NEC 705.12(A)]
2)L THE POWER SOURCE OUTPUT CIRCUIT CURRENT MULTIPLIED BY 125 PERCENT SHALL BE U SED IN
ALF ACI TY C ALC U LAT 10 N S [HED 70& 12(8)]
3) EQUIPMENT 0 ONTAINING OVER CURREN T DEV IC ES IN CIR QUITS SU PIPLYING POWER TO A BUS BAR OR
SON DU CTOR SHALL BE MkRKED TO IN DICATE THE PRESENC E OF ALL SOURCES. [NEC 705AW]]
4j GIRCIJ IT EP. EAKER, F: BACK FED, SHALL BE SU ITAELE FOR SUC H OPERATION. [NEC
WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL, BE
INSTALLED AT THE OPPOSITE END OF THE EJ SEAR OF THE MAIN 131REAFER.
TO REDUCE FIRE HAZAFMS., DC FV SYSTEMS WI LEE EC)U IPPED 'hV ITH AGROUND FAULT PROTECTION
SvS TEM INACCOR DAINCE %VITH NEC 090.41(8)
WHERE GROUND -FAUL7 PROTECTION tS USEDE Tri E OSLI TPU TOF AN INTERACTIVE SYSTEM SHALL BE
C ON NECTED TO THE SU PPL.Y SID E -Z OF- THE GR OUND FAULT PROTECTION [NEC 7705 32]
is ALL PLAQUES AND SIGNAGE REQUIRED BY THE. LATEST EDIT K:IN OF NAT ION AL ELES TP. CODE LA13EL
SHALL BE METALL IC OR PLASTIC, ENGRAVED OR MAZHINE PRINTED IN A CONT RAST F-4 G C CLOR TO THE
PLAQU E.. PLAQUE SH ALL 13E U V RES11STAN T F EXP OSE D TO SUN U G HT.
In ALL THE NEC REQUIRED WARNING SICNS, MAR 19INGS. AND LAEELS SHALL BE POSTED ON EQUIPVIENT
.
AND DISCONNECTS PRIOR TO ANY INSP�:EC TIONS TO BE PERFORIVED BY THE BUILD f4G DEFARTWENT.
4 CONNECTORS SHALL EE OF LATCH ff,`llG3 OR LOCEZING TYPE. CONNECTORS THAT AIRE READ ILY
ACC"E.SSIB LE AND OPERA71NG AT OVER 30 VOLTS SH ALL R EMU IRE TOOL TO OPEN AND hAARIEEE D'OO NOT
0 IS COSI NECT UN DER LOAD " OR "NOT FOR CUR RENT INTERR UPTINGO. M ER E MATING CONN EC TORS AR E
NOT 0�0_ THE ID ENTICALTYPE AND BRAN D. THEY SHALL BE LISTED AN D ID EN TIF IED FOR
IINN TERMATAJBILATY, AS DESCRIBED IN THE MikNUFAC TURER'S INSTR UCTIONS.. [N EC 090.33�C] & (E) (2)]
4 FLEABLE, FIN E-STRAM DED CABLES SH ALL, 13E TERMINATED ONLY WITH TERMIN ALS, LUGS, DEVIC ES, OR
G ON NECTORS 114 AC r.,'-'0RDAN ICE AF ITH NEC 110-14
4 WORK CLEARANCES AROUND ELECTRICAL. EQUIPMENT WILL BE.MAIN TAIISI EIS PER NEC 110.20-NA.J(1)0
14
110.2f1'AX2)A_NF3 110_2D(A):(3j.
a ALL EXTER 11OR C ON DU ITS - - ITTINGS AND BOXES SHALL BE RAIN -TIGHT AND ,AP PR OVED FOR USE JN WET
LOCATIONS PER NEC 314.1&
4 ROOFTOP L40UNTED PHOTOVOLTAIC PANELS AND MODULES SHALL. BE TESTED.. LISTED & IDENTIFIED IN
ACCORDANCE WITH UL1703
EACH MODULE 70 BE GROUNDED USING THE SUPPLIED CONN ESTI ON PONT PER LEAN UFACT,-IRBR'S
REOMAREKIEN TS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE 7013E BONDED.
IF THE MSTING GROUNDING ELECTR ODE SYSTEM CAN NOT BE VER IF ED OR 15 ONLY IME TALL IC WATER
PIPING, IT IS TH E C ON7RtAC-TCR,'S R ESPONSIBILITY TO IN STALL A SUPPLEMENTAL GROUND [ING
ELECTRODE -
a DC C ON DU GTOR S SHALL:: BE RU N IN EMT AND SH ALL BE LAB ELED .. 'C ALJ TION ID C C IRC U IT " OR, EQU IVI
EVER' 5 FT_
4 C 13N FIRM LINE SID E VOLTAGE AT R EGTR IG UTIUTY SERVICE PRIOR TO C ON NECTI %JG INVERTER_ VERIFY
SERVICE VOLTAGE IS WITH IN INVERTER VOLTAGE OPERATIONAL IRAN GE -
4 S&R V I N G IJ71 L ITS' TO 18 E N 0 T! RED BEFORE ACTIVATION OF PV SYSTEM
1-
4 ELEC TRICAL CONTR ACTOR. TO PROVIDE GON DU IT EXPANSION JOINTS AIN D AN DH OR CON IDUIT RUN SAS
REQUIRED PER NEC..
Nl - GENERAL NOTES
DISTRIBUTION PANEL (EXT)
SERVICE POINT & UTILITY METERING
AC DISCONNECT
INVERTER
CONDUIT
JUNCTION BOX
10675 W 47TH AVE
DWELLING
881-101211
W 47TH AVENUE
SCALE: 1 11
NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY
- SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME:
0
- ALL DIMENSIONS IN FEET UNLESS - INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF ADDRESS: 04/29/21 `
OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING PHONE NUMBER:
WORK
PROJECT: 10675 W 47TH AVE
TITAN SOLAR MUNICIPALITY: WHEAT RIDGE CO AUTHOR: EE S1 -SITE PLAN
' Exp. 10/31/21
T I T A t4 PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21
CLIENT: RAYMOND E BEST
WSJ:;3.330 kW DC-STC/3.000 kW -AC ,,1.� .TITANSOLARPOWER.COM -
REV. -
ELECTRICAL POWER 6 SAFETY CL
/
PVC VENT
® METAL VENT
VENT BOX
STRUCTURAL
DELIMITER
0 SERVICE
MAST
O SATELLITE
� ANTENNA
SNOW GUARD
DOWNSPOUT
ELECTRICAL
MOUNT
RAIL
TOP CHORD
DECIDUOUS TREE \
TREETOP: 72' �
DECIDUOUS TREE
TREETOP: 74'
O
O
DECIDUOUS TREE
TREETOP: 36'
651-611
VMARA;F
.oe4 4,
o•.
DECIDUOUS TREE J
TREETOP: 46'
7r
MOUNTING PATTERN SAMPLE I
MAXIMUM MOUNT SPACING: 48"
MOUNT PATTERN: STAGGERED
ALL HARDWARE, INCLUDING MOUNTING
AND RACKING, TO BE INSTALLED PER
MANUFACTURER SPECIFICATIONS.
CONIFEROUS TRE
TREETOP:
DECIDUOUS TREES
� TREETOP: 13'
� L ROOF 1
PITCH 18.50 DECIDUOUS TREE
DECIDUOUS TREE � / DECIDUOUS TREE TREETOP: 46'
TREETOP: 38' TREETOP: 46' AZM 179
SCALE: 1 "=8'
ROOF PITCH: 18.5° SLOPED SHINGLE ROOF
PANEL TYPE: SILFAB SIL -370 NX
ROOF 1 AREA: 554.43 FT
NOTES:
AZIMUTHS: 179°
PANEL SIZE: 72.13" X 39.4"
ARRAY AREA: 177.62 FT
- SOLAR PANEL LAYOUT SUBJECT TO CHANGE
RACKING TYPE. EVEREST CROSSRAIL 44X
NUMBER OF PANELS. 9
o
ARRAY PERCENT COVERAGE. 32.0%
ACCORDING TO EXISTING CONDITIONS 0
o4i29i2�
MOUNT TYPE. QUICKBOLT MICROFLASHING
SYSTEM SIZE. 3.330 kW
A
- SCALE AS SHOWN'
vm
- ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED''
58
PROJECT: 10675 W 47TH AVE
TITAN SOLAR MUNICIPALITY: WHEAT RIDGE, CO AUTHOR: EE S2 -PANEL LAYOUT
NAL
PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 Exp. 10/31/21 U
P ��J E WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST pSC�
3.330 kW DC-STC/3.000 kW -AC REV: -
ELECTRICAL POWER 6 SAFETY CO.
MODULE
SCALE: NTS
PANEL TYPE: SILFAB SIL -370 NX
PANEL SIZE: 72.13" x 39.4"
RACKING TYPE: EVEREST CROSSRAIL 44X
MOUNT TYPE. QUICKBOLT MICROFLASHING
EVEREST 44X RAIL
0111C;KROI T
WOODEN
STRUCTURAL
MEMBER
NOTES:
- SCALE AS SHOWN
- DIMENSIONS IN FEET UNLESS
OTHERWISE STATED
FLASHING
LAG SCREWS SHALL
BE S.S. 5/16" DIA W/
2.5" MIN EMBED IN
RAFTERS/TRUSS TOP
CHORDS
04/29/21
� �N
52158
PROJECT: 10675 W 47TH AVE
TITAN SOLAR MUNICIPALITY: WHEAT RIDGE, CO AUTHOR: EE S3 -STRUCTURAL DETAIL
TI TA L11iAL�
PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 Exp. 10/31/21 �
P ��J E WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST pSCO
3.330 kW DC-STC/3.000 kW -AC REV: -
ELECTRICAL POWER 6 SAFETY CO.
NOTE:
PV PRODUCTION METER NOT REQUIRED DUE TO THE SYSTEM SIZE BEING LESS THAN 10KW.
STRING OF SILFAB SIL -370 NX MODULES
EACH CONNECTED TO OPTIMIZERS
L
«iMAI a 15k1, 1.M"m I mk ": N
VISIBLE, LOCKABLE
INVERTER 1(1) NEMA3R
SOLAREDGE SE3000H-US Y 30A SWITCH
NON-FUSED
SEE INVERTER
JUNCTION BOX SUMMARY TABLE FOR /
NEMA3R NUMBER OF STRINGS
AND STRING LENGTHS
/ r1 , I 11---0_-fit--
BI-DIRECTIONAL UTILITY METER
TO BE INSTALLED BY XCEL ENERGY - CO
LABELLED "PHOTOVOLTAIC
SYSTEM CONNECTED"
240V, 200A
MAIN SERVICE PANEL
240/120 V 10, 3W, 200A
vi vv
EATON DG221 URB
AC ISOLATION DEVICE, NEMA 3R PV SYSTEM AC � EXISTING
EQUIPPED WITH DC DISCONNECT DISCONNECT
SWITCH = GEC
LABELLED "PV AC
DISCONNECT"
WITHIN 10' OF BILLING
Approval Notes: METER
1) PN array system to have grounding system installed per Part III of
Article 250 per 2020 NEC Article 690.47(A).
2) If UFER ground in not available provide or verify supplemental
ground rods per 2020 NEC Article 250.53(A)(3).
3) Cold & Hot Water & Natural Gas bonding per 2020 NEC Article 250.104(A)(B)
Inverter
Inverter
Inverter
Number of
Inverter
Module
Module
Optimizer
Optimizer
String
#of
Circuit
String
DC Power
AC Power
DC:AC Ratio
!D
Manufacturer
Model
Inputs
Input
Manufacturer
Model
Manufacturer
Madel
Length
Optimizers
Current
Power
1
SILFAB
SIL -370 NX
SolarEdge
P370
9
9
15A
31330W
5E 9 NV1
SolarEdge
SE3000H-US (240V)
2
3133dW
31000W
1.11
2
SILFAB
SIL -370 NX
SolarEdge
P370
0
0
15A
OW
TITAN SOLAR PROJECT: 10675 W 47TH AVE
MUNICIPALITY: WHEAT RIDGE, COI T A 11 AUTHOR: EE E1 -LINE DIAGRAM
PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21
WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC REV: -
city of
S./D.ZoZ/
04/29/21 �. 0 0��C
� 0N
52158
Exp. 10/31/21 %NAt.
PSCO
DC CONDUCTOR SCHEDULE
MODULES TO JUNCTION BOX
*TEMPERATURE FACTOR IS BASED ON 2% DRYBULB HIGH TEMPERATURE OF 31.4°C WITH A O*C TEMPERATURE ADDER THEREFORE RACEWAYS MUST BEAT LEAST0.75 INCHES ABOVE ROOF AS PER NEC 310.15(B)(3)(C)
Number of Conductor Conductor Conductor
Base Ampacity *Temperature Fill Derated Circuit Min. OCPD EGC EGC EGC
Conductor
Conduit
Strings Material Type Size
@ 00°C Factor Factor Ampacity Current (If Required) Material Type Size
No Limit CU PV Wire 10 AWG
40A 0.96 1.00 38.40A t 15.00A 20A CU BARE 6 AWG N/A - Free Air
JUNCTION BOX TO INVERTER
*TEMPERATURE FACTOR IS BASED ON 2% DRY BULB HIGH TEMPERATU'R'E OF 31.40E WITH A OOC TEMPERATURE ADDER THEREFORE RACEWAYS MUST BE AT LEAST 0.75 INCHES ABOVE ROOF AS PER NEC 310. 15(B)(3)(C)
"TABLE ASSU MES ON E EGC PER CON DU IT. MI N I MU M ON E EGC IS REQU I RED PE. R I NVERTER PER CON DU IT.
Number of
Conductor
Conductor
Conductor
Base Ampacity
*Temperature
Fill
Derated
Circuit
Min. OCPD
EGC
EGC
EGC
Temp.
Conductor
Ampacity
Max
Derated
# of
Neutral
Ground
Ground
Conduit
Conduit
ID
From
Min. EMT Size
Strings
Material
Type
Size
@ 00°C
Factor
Factor
Ampacity
Current
(If Required)
Material
Type
Size
Ampacity
1
CU
THWN-2
10 AWG
40A
0.96
1.00
38.40A
15.00A
20A
CU
THWN-2
10 AWG
0.50 in.
AC CONDUCTOR SCHEDULE
v TITAN
TITAN SOLAR
PHONE: 1 -855 -SAY -SOLAR
WWW.TITANSOLARPOWER.COM
PROJECT: 10675 W 47TH AVE
MUNICIPALITY: WHEAT RIDGE, CO
ZIP CODE: 80033
CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC
AUTHOR. EE
DATE: 27/APR/21
REV- -
E2 - ELECTRICAL CALCULATIONS
04/29/21 DO t
vn
52158
Exp. 10/31/21
CPSCO,
ELECTRICAL POWER 5 SAFETY CO.
AC
Circuit
125`?'
OCPD
Conductor
Fill
Am bient
Temp.
Conductor
Ampacity
Max
Derated
# of
Neutral
Ground
Ground
Conduit
Conduit
ID
From
T -C,
Phase
Vo Itage
Current
Multiplier
(If Present)
C3 L erial
Type
# of CCCs
Factor
Temp.
Factor r
Size
@ 7 5 ��'C
Ampacity
Ampacity
Neutrals
Size
Ground
Type
Size
Type
Size
I
SE I NV1
L-, F 17 1') I't
10
240 (V)
12.5 (A)
15. 6 (A)
20 (A)
Cu
THWN -2
2
1.00
31.4( -C)
0.96
12 AWG
25 (A)
30 (A)
28.8 (A)
1
12 AWG
EGC
THWN -2
12 AWG
E rvI T
x.50 (in.)
AC Disconnect 1
10
240 (V)
12.5 (A)
15.6 (A)
20 (A)
Cu
THWN-2
2
1.00
31.4
0.96
12 AWG
25 (A)
30 (A)
28.8 (A)
1
12 AWG
EGC
THWN-2
12 AWG
E N1 T
0.50 (in.)
v TITAN
TITAN SOLAR
PHONE: 1 -855 -SAY -SOLAR
WWW.TITANSOLARPOWER.COM
PROJECT: 10675 W 47TH AVE
MUNICIPALITY: WHEAT RIDGE, CO
ZIP CODE: 80033
CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC
AUTHOR. EE
DATE: 27/APR/21
REV- -
E2 - ELECTRICAL CALCULATIONS
04/29/21 DO t
vn
52158
Exp. 10/31/21
CPSCO,
ELECTRICAL POWER 5 SAFETY CO.
WARNING
ELECTRIC SHOCK HAZARD
TERMINALS ON BOTH THE LINE AND LOAD SIDE
MAY BY ENERGIZED IN THE OPEN POSITION
[NEC 690.13(B)] PLACE THIS LABEL ON ALL
DISCONNECTING MEANS WHERE
ENERGIZED IN AN OPEN POSITION
WARNING
PHOTOVOLTAIC
POWER SOURCE
[NEC 690.31(D)(2)] PLACE ON ALL JUNCTION
BOXES. EXPOSED RACEWAYS EVERY 10'
WARNING
POWER SOURCE OUTPUT CONNECTION DO
NOT RELOCATE THIS OVERCURRENT DEVICE
[NEC 705.12(8)(3)(2)] PLACE THIS LABEL AT
P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT
(I.E. MAIN PANEL OR SUB—PANEL) IF APPLICABLE
WARNING
THIS EQUIPMENT FED BY MULTIPLE SOURCES.
TOTAL RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN SUPPLY
OVERCURRENT DEVICE SHALL NOT EXCEED
AMPACITY OF BUSBAR.
[NEC 690.56(C)(2)] PLACE NO MORE THAN 3.3FT
FROM SWITCH
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
S°P PANELSRIC
SHOCK HAZARD IN THE
ARRAY.
[NEC 690.56(C)] PLACE AT MAIN SERVICE PANEL
PLACE THIS LABEL WITHIN MAIN SERVICE DISCONNECT (OR ON OUTSIDE
DISCONNECT OF OPERABLE WITH COVER CLOSED)
CAUTION: SOLAR
ELECTRIC SYSTEM
CAUTION
CONTAINS MULTIPLE
POWER SOURCES
[NEC 705.12(8)(3)(3)] PLACE THIS LABEL AT [NEC 705.12(C)] PLACE LABEL ON ALL EQUIPMENT CONTAINING
P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER
(I.E. MAIN PANEL OR SUB—PANEL) IF APPLICABLE TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES
NOTES:
1) ALL LABELING USED OUTDOORS MUST BE ENGRAVED METAL, UV STABILIZED ENGRAVED PLASTIC OR OF A MATERIAL SUFFICIENTLY
DURABLE TO WITHSTAND THE ENVIRONMENT INVOLVED. VALUES HAND WRITTEN OR IN WRITTEN IN MARKER ARE NOT ACCEPTABLE
PER NEC 2020.
2) LABELS USED INDOORS MAY BE MADE OF DURABLE VINYL OR PAPER
3) DO NOT COVER ANY EXISTING MANUFACTURER APPLIED LABELS WITH INSTALLATION SPECIFIC LABELS
4) LABEL COLORS CHOSEN PER NFPA 70 2020 DIRECTION THAT ANSI Z535-2011 BE USED
5) ALL FORMATTING SHALL COMPLY WITH NEC 2020
6) ADDITIONALLY, IT IS HIGHLY RECOMMENDED THAT THE INSTALLER ATTACH A LABEL WITH THE COMPANY NAME AND CONTACT
INFORMATION AT THE INVERTER
7) ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(8)
T 11 PROJECT: 10675 W 47TH AVE
TITAN SOLAR MUNICIPALITY: WHEAT RIDGE CO I TA ti
PHONE: 1-855—SAY—SOLAR ZIP CODE: 80033
CLIENT: RAYMOND E BEST
L `A�� R P 0 lo, R .TITANSOLARPOWER.COM 3.330 kW DC—STC/3.000 kW—AC
[NEC 690.13(B)] ALL AC DISCONNECT SHALL BE
LABELED
:.D(C PHOTOVOLTAIC
DISCONNECT
[NEC 690.13(6)] ALL DC DISCONNECT SHALL BE
LABELED
[NEC 690.54] PLACE LABEL AT "POINT OF
INTERCONNECT 1"
[NEC 690.53] PLACE AT INVERTER 1
FORMAT
1. MINIMUM 3/8 INCHES LETTER HEIGHT
2. ALL LETTERS SHALL BE CAPITALIZED
3. ARIAL OR SIMILAR FONT (NON—BOLD)
RAATPPIAI
PHOTOVOLTAIC
SYSTEM
CONNECTED
UTILITY METER SHALL BE LABELED
PHOTOVOLTAIC
AC
DISCONNECT
AC DISCONNECT SHALL BE LABELED
REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT
(USE UL -969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS
AUTHOR: EE
DATE: 2 7/APR/21
REV: —
E3 — WARNING LABELS
04/29/21
� N
52158
Exp. 10/31/2 Aplt.
p 0
ELECTRICAL POWER 6 SAFETY CO.
P A N E L
JUST ER I
KA
kA :5 r (79UA N 0 9 L E
251- -1 N-
$1]
MA 101RODUCT 4L $ HIGH
TIME $$$ 111*jow
NDUSTRY LEADING WARRANTY
1he Titan Solar Panel is manufactured by Silfab Solar
ind includes an industry leading 25 -year product
tormanshlp and 30 -year perfori-nance warranty.
AAXIMUM ENERGY OUTPUT
.everaging over 35+ years of worldwide
xperience in the solar industry, Silfab is dedicated to
uperior manufactu d ng processes and innovations
arc has Bifacial and Back Contact technologies, to
�nsure our partners, such as Titan Solar have the
3test I n so la r I nnovation.
SIO RTH AMERICAN QUALITY
'H'Ifab is the leading automated solar module
manufacturer in North America, UtIlicEing
rem lum qual i*ty materials and strict quality control
rianagement to deliver the highest efficiency,
rem lum quality Wmodules-
spa BAA / A RRA COM P LIA N T
These panels are designed and manufactured to meet Buy Ame-
rican Act Con-ipliance The US State Departrnent, US Military
and FAA have all utilizi-i-d Silfab panels in their solar Installations.
;0;009 LIGHT AN D DURABLE
Engineered to accornmoJate high wind load -conditions for test
loads validated up to 4OHO OPa uplift The light -weight frame
is -exclusively designed for wlde-ranping racking compatibility
and durability
1H QUALITY MATTERS
Total autornation c-risixes strict quality -controls during the entire
manufacturing process at ISO certified facilitli-'-s
,91 DOM ESTI C SU PPORT I S ERV I CES
Our 500t North American team is ready to help Titan Solar
v,i n the hearts a nd mi nids of c ustomcers. provid IN custo mer
service a nd produc t d elly*--r-y that is di rest, effic le nt a nd I teal
iii AESTHETICALLY PLEASING
Ad I blas k sl eek design, idea I for high -profil e resident ial or
commercial ap pl ications,
;61! PID RESISTANT
PIE) Resistant due to advanced cell technology and material
s-A_l,;_-<tion In accordance to IEC 62804-1.
TITAN SOLAR
PHONE: 1-855—SAY—SOLAR
WWW.TITANSOLARPOWER.COM
T,w+
SIL -370 NX mono FERC
STC NOCT
Module Rawer (Pmm)
WF
370
266
MmirnurTn power vchaae CVprnm)
V
37.2
332
Mim i rn u m paws r current Opmut)
A
10.0
7.9
Lan circtit vcltap (Voc)
V
44.8
407
Short circuit current 099)
A
10.6
83
M DdLife OR C i en!y
%
20.2
18.2
Mmirnum system vokage (VDC)
V
Junction Box
1000
Swim ftim rating
A
Module product yvorkrnanshipwarranty
20
PowerToleranceWF
-q-3%
Naar umnoct cm&mw STC 1000 W.Wa - AM t - Twqwmburs 2S'C - NXT SWOYSn' 4 AM IS - Mmumi.mi uncw-wiitys 3%
-Sum iear Int wcdbr@6m rw(wmc&mv&jk3 from Framh4for IndRjA4. ElociAcji c6ractaistin" vvy by IS% mid paaw 6y+b3%.
TwTwatum Caagciant Inc
7"TG,raturia Cwffident Voc
Twrparwturs CoAcient Pit
SIL -570 NX rnc4no PERC
(i - 0" V 3 C
4122 "C
n QA T_rr
Mug_ 1 (* X_W1
40-N..
Opera tinp temperature
-40/+85 *C
ir op •
u1not It . MIM I a 4 Iff, I All Kor*, A 11
SIL -370 NX mons. PERC
Modul-2 wrAight
44-40A Ibs
Dirnwaiws (H x L x D.)
72.0 in x 39.4 in X 1.5 in
Max i rn u m s u rFa ce I cad (w i n des n <Yow)'
93.5Al2,8 I b�ft"'2
Hail impact resistance
o 1 in at 51.6 M-0—
'Calk
66 - S www -PE RC - 5 buster, 6'.25 z 62.25 in
Glass
0.Q6 in hilL"rumittmrwm, twTfeniicl, DSM anti -PsAmt" cwting
Cab lei and eco nriGctears (rwfw im irdulevan ma rPA)
47.2 in, s 0.22 in, MC4fiwn Stul:Ai
Backihoa
Hth durab3hy, supericr!ydmsus and.Wrwistmnca, mdi-1 ar dielectric film, fluorirw4w PV backime
Frame
Anodized Alurninurn (136ck)
clodes
3 clo,.6-30SQ045T (45V rmm CC blockingwAVe, JOA rrmx ;cc"wd rs-ctiFood curmW,
Junction Box
U L 3730 Cortif6d, I EC 62790 CartAed, I P67 rated
Werrenties
SIL- 370 NX mono FERC
Module product yvorkrnanshipwarranty
25 )roars`'
Uroaar power pwforToncro guarantoe
Product
Factory
30 years
k 97.1% and l'year 2:91.6% and 1T' year 1 2:85.1% and 5" your 2t 62 A% and 30P" aw
SIL -370 KX mom FERC
ULC ORD C1703, U L1703, CEC listrwde", U L 61215-11-1 Af- 2, U L 61730 -If -21
IEC 612154-114-2l". I EC 61730-111-2wo. CSA C22-24617304-2- I K 62716
Aim nTania Cami6n; IEG617DI:2011 SaltMist Carrion gmtfig U LRm Rating TyFe 2
15090UI:2015
All statas;x:epri C;difomij Calftnia
Moldas Per Nlar 26 Jul od u krs ke Pal I in: 26
Pa I 4c s Par Truck: 34 Pzi I lx s Pear Truk: 32
M oJ J a s N r Truck: 94 Modulps Rw Truck; 8,32
*A Wa rni rq. Pka tl'thia Swk;cf wd Inm lat ion Mzxai fur
rn o unE rg zpQc f d cm an d LQfcx,& [wrpzl h g, irua I irg a nd
op;raicing modulos.
'12 yow %x i rad" to 2 5 yea rs sm b.k a to maim r6on an d corn-
'
o ns o Lrd in ad u rvl r 0Wj rr3 n V n wwwsiffik-sd mr. ccm
' %CoH fi cido n and C CC I rd rq in pvqw.
PAN files giiinorawd from 3rd pray p4diccmwr.a dm are
w a i la bb for &-mri old am:
sib arae om1&nwrJoads,
o
Silfab
WLAX
MOM
PROJECT: 10675 W 47TH AVE
MUNICIPALITY: WHEAT RIDGE, CO
ZIP CODE: 80033
CLIENT: RAYMOND E BEST
3.330 kW DC—STC/3.000 kW—AC
rrta n Solar Powror
525W Bzolino Rd
Mcm, Al 85210
Td 855 SAY -'SCS LA R
rrta n s a"" 0 L COM
i n FbaSt it wad a rF>7&Gc
Silfk Sd;r Inc.
2AO C owt n ey W. Drive East
M i&si sa u ga 0 N L5T 2Y3 Cz-"
TQ1 fl 905-255r2W Fax *19-05-696-02,G
i n FW @ s i Fzbsca.2r.--_ cm wwwz I Fa be c4. c cm
Silf2b Sd2r Inc.
WO Cornwal Aefo
Wli-tg+um WA 98225 USA
Td 1•1360-569-4793
AUTHOR. EE
DATE: 27/APR/21
REV- —
- 114
F
C" at
N 40
� S
of
39 11, PsEerr
32 3.1, 1 1AX or ri
A 04/29/21
a
14 bA
Al — PANEL SPECIFICATIONS
Vill
52158
Exp. 10/31/ 1 WAL
CPSCO,
ELECTRICAL POWER 5 SAFETY CO.
0
(;rossRall LILI—X
&
IvIechanic-ml Propeia Lies
Material
Ultimate Tensile Strength
Yield Strength
Weight
Finish
Se(Ai c i� Iii~ �� L
5X
Sy
A (-Section)
6,000 Series Aluminum
37.7 Iasi (260 MPa)
34.8 ks (240 MPa)
0.47 1 bs/ft (0.699 kg/m)
Mill or Dark Anodized
0.1490 In 3 (0.3785 CM3)
0.1450 in3l(0.36,83 CM3)
0.4050 in' (1.0287 CM2)
Technical data
Roof Type
Material
Flexibility
PV Modules
Module Orientation
Roof Attachment
Structural Validity
39 I 4216.40
1.54 166 Warranty
Dimensions in [mm] Inches
Notes:
Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-16
UL2703 Listed System for Fire and Bonding
V V
CrossRail System years
Composition shingle, tile, standing seam
High corrosion resistance stainless steel and high
grade aluminum
Modular construction, suitable for any system size,
height adjustable
For all common module types
Portrait and landscape
Screw connection into, rafter
IBC compiiant,, stamped engineering letters available
for all solar states
25 years
F C" of N
k MAff 6t)ak4A1
s.�o 2ou
Or 1)0
............... ww�ni.evierest-sclarsystemq.ccni www,everest-salarsystemsxcni 04/29/21
� N
52158
TITAN SOLAR PROJECT: 10675 W 47TH AVE AUTHOR: A2 -RACKING SPECIFICATIONS
4 1 MUNICIPALITY: WHEAT RIDGE, CO I I 0
T I T A PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21 Exp. 10/31/21
WWW.TITANSOLARPOWER.COM CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC REV- -Cf�SCO,
ELECTRICAL POWER 5 SAFETY CO.
SPEC SHEET
Part #
Box Quantity
17664
5.25" Bolts (10)
17666
3"' Microflashing(D (10); 5.25" Bolts (10)
17667SS
3" MicroflashingOO (25); 5.25" Bolts (25); L -Foot (25); 5/16"
Serrated Hex Flange Nuts (25)
Micraflca5hi nock.
Part # 17669
5/16$1 x 3"
304 Stainless Steel
Compression Washer Black
Part# 1765 9
5/16" x 4"
304 Stainless Steel
Compression Washer Black
5830 Las Positas Rand, Livermore CA 94551 1 3948 Airway Drive, Rack Hill SC 29732
Phone: (844) 671-6045 1 Fa c: (80-0) 689-7975 75 1 www.quickbolt.com
,►uickBOLT is a division of Quickscrews International Corp.
TITA I
S O L A R P O W E R
TITAN SOLAR
PHONE: 1 -855 -SAY -SOLAR
WWW.TITANSOLARPOWER.COM
PROJECT: 10675 W 47TH AVE
MUNICIPALITY: WHEAT RIDGE, CO
ZIP CODE: 80033
CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC
Part * 17 664
5/16-18 X 5.26,
304 Stainless Steel
Removable Hangar !Bolts
0.14"
W
5¢-4 "�
Part # 17669
5/1611 "
304 Stainless Steel
Compression Washer Black
Notvral colovtlack
1 )4S S
1 794 S S
b
LL
L
41 -nm I hick � +
I -
4 j
4.0
I
4C
Custmer
Technical requir nt : The limns ions of the hooks ars; in accordance with the €irerings.
Surface smooth, without burr.
& 2 mm Matertal
304SS
mfr.
Svlc k?lmwxc
± m rt't
Hole durtame kAzz=
t 0.5 r -r-1 r r 7
Deft;
2017, 11.28
Aud i, for :
r .wdoxw�
* 2 mm
,e..
0.1 n -i m
Ajle tali ee
4 1* MM
5830 Las Positos Road, Livermore CA 94551 I 3948 Airway Drive, Rock Hill SC 29732
Phone: (844) 671-6045 1 Fcx: (800) 689-7975 j www,quickbolt.com
QuickBOLT is a division of Quickscrews International Corp.
AUTHOR: EE
DATE: 2 7/APR/21
REV: -
A3 - MOUNTING SPECIFICATIONS
city of
04/29/21
c`9 E
Vn
158
Exp. 10/31/21 ONAL
P 0,
ELECTRICAL POWER 6 SAFETY CO.
/Sin --le Phase Inverter
0
wit HD -Wave Technology for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/
SE7600H-US / SE10000H-US / SE11400H-US
SE300OH-US SE38OM-US SE5000H-US SE600OH-US SE7WH-US SE16I)CAC
OUTPUT
Med AC ftYmat Qj1put
303
313W 4P 240Y
10 * 24M
75aD
100DO
1U00 0 MY VA
W
MWn'KJM IK P001IN 0M_ V
3300 4P 205V
5'00 0 206V
W
Tf amtmw-im Ung mvidW
10000 0 zw
MammiLm AC Pbwff ouipa
30DO
3800 0 24 -JV
D'@ 6WD,@ 24(N
760D
100co
114M 0 24av VA
380
400
3300 4P 2M
1 50 CC Q 2CGV
115 W 165 20
27 3-
Adc
AC Outpts %tkAge k4mANIbm-Max
9 133
27
Addle
stonccurrMoit
VIC
Q11 - 240 - 2K
Ade
0
AC Oulptl %tKage lmvmm-Mft�
&33 Iu se M my
.01
Wiftftm kse-r sef E f IF
992
00 - 2W- 2M
CIC Migh*J Miemy
99
99,0 240Y 0
AS 2M
AC F*quaxy tin -a.4
59-3 - 60 - 60-50 Hit
MaIOMLM CCrbftxxA Wput12.5
25 32
Q
J7.5 A
CLyreft 92'm
supmlw coftv"UnkAim Intert&es
IRSU$, � ZkAft Optcei.*, Cellular (OpWAJ4
Woman CC(th.CXA OLAPut
hewme Grade D" ANSI C1220
15
24
4&5►
CurretV 02COV
STANDARD COMPLIANCE
SAA&V
My ktorftu hg. kd&o_;
P*Awtb, Cntydry Cnnlojr,, -
1UE1547. Rae 2t MA 14
Thmdtddi
4
INPUT
Madnxm DC Pt W 024W 465ta
59M 7750 &M V"
155M 17650
W
MWn'KJM IK P001IN 0M_ V
Sim 7M
- IWO
W
Tf amtmw-im Ung mvidW
Ves
M410iman hvtA %titage
480
%dC
NCM rid OC InpA "age
380
400
M"mum hW CurreM 0240VO &5
115 W 165 20
27 3-
Adc
Munn iqW Current 020OW
9 133
27
Addle
stonccurrMoit
45
Ade
0
Gound-Fault hoWhm (Wed ion
&33 Iu se M my
Wiftftm kse-r sef E f IF
992
CIC Migh*J Miemy
99
99,0 240Y 0
AS 2M
76
No H&ft Power Conmongtioa
2.5
W
AODFFMAL FEATURES
supmlw coftv"UnkAim Intert&es
IRSU$, � ZkAft Optcei.*, Cellular (OpWAJ4
hewme Grade D" ANSI C1220
optknw
P.WW ShUtdoYm
2017 6900?
&Aonvok RApid Shuukwn upon AC Gnd Dsconed
STANDARD COMPLIANCE
SAA&V
U111.1741, UL1741 SA, M1669& CSA C22Z CoWien AFC1 aacwdinq to UL M-07
GO Con rt!ir- tic- 0 SIS'A&ds
1UE1547. Rae 2t MA 14
4
_Emizicm
FCC W 15 CLzs I
INSTALLATION SPIECIRCATIONS
AC WpU C"jt Sge f AVOIG
RWqe
3f4* rn n i -P u fn / 14-6 A%G
3/4" worimum, A" AMG
DC InpLi CafdAt Stm 18 of StOgs d
AWG Ro%ge
3/4m rninkvum / 1-2 2 f U-6 AM
3/40 minnium / 1-3 wings 11" AWG
Doweoiom with S*4y 5* Ott h
17.7 x 14-6 x 6.11 / 450 x 370 x 174
2,13 x 14.6 x 7"31540 x 370 x 195
in
Vkiot wAth $Sky Svs*% 22/10
1 25.1 / M 262 M
M 117.6
lb 114
�Nkw
-C 25
'C50
dRA
CON"_
katafal C-brW604%
ow"Ag *fflPfAt" RNW
-40, to +M / -25 to +W* (-40 / -KC op"10
If*(
pmection R&nq
Int M& 4X onvertef valh Safe -y. Swkchl
4 F<r c1hw ural w"i O&K* cwW SdwEd5p affon
0 A Npier c~ mace rray be u 2@4 the Vw&nv W11 VW Its irput aAwt W its vA6ds OW
0 Phrimus 9rade i nvwtor " st MIN #350 NU
W) For pcmw do -rwriq Wkrmdkn ref v Ux h*Wtw 1Wx2rnLPCff
NJ -410 VWdM P'N' St WN AJ90CCMA"
goo crmpodorW fiedw aryls c0!d9m1*p Ire A]
cd . truhmarks nommed boron o baden a its V rho, rrarprcrirr ax rom zM QM*VW*~ Sao" so ft chinp W&CM MCI=
RoHS
Single
PhIt ase nvererz
with HD -Wave Technology< M
for North America X_
SE300aH US SE3800H-US / SESOOOH US / SE6000H US
SE7600H-US SE10000H-US SE11400H-US "i
m
solar =*F;a
V 1
4Wx
W
Optimized installation with HD -Wave technology
I Specifically designed to work with I Extremely small
power optimizers
I Record-breaking efficiency I Built-in module -level monitoring
I Fixed voltage inverter for longer strings I Outdoor and indocr installation
I Integrated arc fault protection and rapid shutdcwn for/ Optional: Revenue grade data, ANSI C12.20
NEC 2014 and 2017, per arb'de 690.11 and 690.12 Class 0.5 (0.5% accuracy)
I UL1741 SA certified, for CP4JC Rule 21 gn'd
compliance
solaredge.com
PROJECT: 10675 W 47TH AVE
TITAN SOLAR MUNICIPALITY: WHEAT RIDGE, CO
T I T A Iq PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033
S 0 L A R P 0 W E R VVWW. TITAN SO LARPOWE R. COM CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC
solar - • •
err
AUTHOR: EE A4 - INVERTER SPECIFICATIONS
DATE: 27/APR/21
REV- -
04/29/21
VM
52158
Exp. 10/31/21 NA
CPSCO,
Power Optimizes•
For North America
P320 / P340 / P370 / P400 / P405 / P505
,IT
UW UW cc %WNWR
4M—
WS
W
-0L AW Wx ru-n hpLd
'Ic
NX at kmVIst XhAW
48 so 1.X0A
UR
WIC
NOPTOW-Arg pa
8 - 60 8-90 U -S - M
U's - 83
Mmer-wn Shon Circa,
11 lal
1A
Adc
M=rLn DC UVLA Cumin
133S i fa
17-S
A&
Wax MWIn EAM" cy
99 S
VM#lwd I ffrmrxy
90.6
%
_UWr%t*XP C409my
I
OU TP UT DU RING 0KRATION (POWER 0 PTIMIZ E R CONNECTED TO OP E RA_n N G SOLA RED> DMRTER)
Kum r-wnOu W. C.6f
—1—AdIc
KAMMY" CX9PA %btve _T
as
OUTPUT DU RING STANDBY POWER OMMIZER DISCONNEICrIED FROM SOLAREDGE TWEKMR OR SQWtEEGE
INVERTER OFF)
m.it Win.
S.ffriy Cu
STANDARD COMPILLANCE
F(L Par: IS Cats IL IMM -&A", I K.61 OM. -f. I
SAV
JEW 109-1 JcL= 3 wkrA LL17-91.
INSTAUATM SPMFICAnOM
Max n- -n Mmad *ftm
CIonva.pbe rramn
Al SolarEcige Sln Ps and nvw Ptow rwun
Cwrien gm JYJ x L v K
12A T Mr 36 1.'�s ls� I SO
18r15:: v 28 5 it 5.97 x 1.1 S x 5.97 x 14.2 5 x S 47 x 1.96
Ve X M it S9
1, 5.97 x 2-32
rrrn I in
Wo4v (rdAng cabir-4
SO/ L4 75011.7 945/19
10612.3
car ilb
In FA Cm-mictme
WCC Q
Ot#Ln Wray TXv / Came=
oautk knkftd MCA
ch -W, Wrr
OL95 10 T 9
m/ ft
Inpt 'mV rt% L,r--qth
a 16 / 051-
M/ ft
Upwalrig-kTrPrn.um Rpr
-V - ISS/ -0- *1AS
'C / T
kdxror Hirri3m,
0-100
RAW src poww of d* fto&Ak WWJ& of up to - 5% P&*Mf XlWaftit Au"d
Nsc ZD17 V4.9'I MAC rpa v -JW" t* rWA (V"* ther- WY
pa" C&JA3 S06VI dq&
P 3 M
NIX 1 Kos 0;
Larigth
C-17new- Oph rram)
S 700 (CM wth
muri'm Pcwv. per Stmg SM -LAS- A 11.400- MA 1275IN W
Parte! Sinings d b1k4m . migft yes
or
"." MKftdWM
F11 k k na Aftad W mk P40VKM aM FM Q*34P3 7% MW ei cr* sir IN
PA " vAlh wAQft *wn 30apknI 4caL ra mm W &Arry wil be A&,* Va 3W mqan�
Fa SMMM&U4 29A k k dowad an eaUl up, @o66WW po sing Wwn 3 iur+.I wqvawd tu en r t3 or pw urk to SULAIRM wtdn
** waakuum V&aw Wkwa%to bwwaoh do " a up a* IAOM
in to S ,E-- -m- 0'6jU4fi6M IVISSMas1 I k A&Md oaf sip 10 1"WN rw .71 'rg witwit 3 ia, tp� a- j,v*awJ to ft iwenw :3 wirpit aW W SMSKAWI OM
aw WAM *a f%ftaLft dfbowina homon d%* wivp a up in ),DMW
Power Optimizer
For North America
P320/P340/P370/P400/P405/P505
25
YEM
!i,4��lllll���'N
r
PV power optimization at the module -level
I Specificallyde.signedto work with SolarEdge
i r ve rte r,.,,
I Up to 25% more energy
I Superior efficiency (9g.5L%)
Mitigates all type -s of module mismatch losses,
from manufacturing tolerance to partial
shading
I Flexible system design for maximum space
utilization
? Fat in-stallaton with a single bolt
N
;a
I Next generation maintenance with module -
level monitoring
I Meets NEC requirements for arc fault
protection (AFCD and Photovoltaic Rapid
Shutdown System (PVRSS)
Module -level voltage shutdown for installer
and firefighter --safety
C" of
S./o 202/
Jolared-C.12.com r.. 04/29/21 solarmR
MOOM—wa-M, www�=I Iry th" amV&-nn ammm DIIIIIIIw NW kood to dm %wrInd yes.CE RcHS A
VM
52158
ITITAN SOLAR PROJECT: 10675 W 47TH AVE AUTHOR: A5 OPTIMIZER SPECIFICATIONS MUNICIPALITY: WHEAT RIDGE, CO I I Exp. 10/31/21 NAL
T I T A Iq PHONE: 1 -855 -SAY -SOLAR ZIP CODE: 80033 DATE: 27/APR/21
S 0 A R P 0 WE R WWW. TITAN SO LARPOWE R. COM CLIENT: RAYMOND E BEST REV- P 0'
1 1 3.330 kW DC-STC/3.000 kW -AC I ELECTRICAL POWER 6 SAFETY CO.
LOCATION OF NEAREST URGENT CARE FACILITY
NAME:
ADDRESS:
PHONE NUMBER:
NOTES:
• INSTALLER SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME
*INSTALLERS SHALL UPDATE NAME, ADDRESS, AND PHONE NUMBER OF
NEAREST URGENT CARE FACILITY RELATIVE TO THE JOB SITE BEFORE
STARTING WORK.
PERSONS COVERED BY THIS JOB SAFETY PLAN
INJURED AT WORK TODAY?
INITIAL YES OR NO
PRINT NAME INITIAL YES NO
UNDERGROUND DIG REQUIRED?
YES PERMIT #
T A Iq
O L t R P 0 ill E
TITAN SOLAR
PHONE: 1 -855 -SAY -SOLAR
WWW.TITANSOLARPOWER.COM
PROJECT: 10675 W 47TH AVE
MUNICIPALITY: WHEAT RIDGE, CO
ZIP CODE: 80033
CLIENT: RAYMOND E BEST
3.330 kW DC-STC/3.000 kW -AC
AUTHOR: EE
DATE: 2 7/APR/21
REV: -
A6 - SAFETY PLAN
04/29/21
� N
52158
Exp. 10/31/21
P 0
ELECTRICAL POWER 6 SAFETY CO.
�..— W—
4, �
AO
RE: 10675 W 47th Ave, Wheat Ridge, CO 80033, USA
To Whom It May Concern,
EP CO
DATE: April 26, 2021
As per your request, we have conducted a structural assessment of the building at the above address.
PV solar panels are proposed to be installed on roof areas as shown in the submitted plans. The panels
are clamped to rails which are attached to the roof with a lagged mounting system. The PV system (PV
modules, racking, mounting hardware, etc.) shall be installed according to the manufacturer's approved
installation specifications. The Engineer of Record and Exactus Energy assume no responsibility for misuse
or improper installation.
It was found that the roof structures satisfactorily meet the applicable standards included in the
IBC 2018, I RC 2018 and I EBC 2018 as well as the design criteria shown below:
Design Criteria:
Wind speed =
105 mph
Ground snow load =
30 psf
Roof snow load =
23.1 psf
Roof dead load =
9 psf
Solar system dead load =
3 psf
Overall, the roof area is structurally adequate to support the PV alteration as per 2018 IEBC Sections
502.4 and 502.5.
This letter was completed in accordance to recognized structural analysis standards, professional
engineering experience, and judgement. Prior to installation, the on-site contractor must notify Exactus
Energy if there are any discrepancies, or damages to the structural members, that was not addressed in
the plan set.
If you have any further questions, please do not hesitate to contact me.
Acknowledged by: 1100C" of
MWAX1
04/29/21 Pot /0j" 0 2J
Digitally signed by David C. Hernandez "� 52158
David C. Hernandez Date: 2021.04.2919:28:52-04:00
Exp. 10/31 /2 1QNAt
P 0
ELECTRICAL POWER 6 SAFETY CO.
ELECTRICAL POWER 6 SAFETY CO.
EP COOperating in: USA. Canada. Mexico P: 651.433.4550
Office Locations: MN - FL - NY - OH - TX - CA E: service@epsco.co
1* � � i City of Wheat Ridge
Residential Solar PERMIT - 202100860
PERMIT NO: 202100860 ISSUED: 05/10/2021
JOB ADDRESS: 10675 W 47th Ave EXPIRES: 05/10/2022
JOB DESCRIPTION: Installation of a Roof -mounted PV solar system. (9) modules 3.330 kW DC
*** CONTACTS ***
OWNER (303)424-9385 HOOD LEASON D
SUB (480)226-6769 DAVID WILLIAMSON 202247 TITAN SOLAR POWER CO
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 17,982.00
FEES
Total Valuation 0.00
Residential Solar 500.00
** TOTAL ** 500.00
*** COMMENTS ***
*** CONDITIONS ***
A printed copy of the permit and city stamped on-site plans must be available on-site for
the first inspection.
Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications,
applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this�permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original permit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any
�pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
05/10/2021
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
IV ' A IV City of Wheat Ridge
_`'`9r
'`9Residential Roofing PERMIT - 201702229
PERMIT NO: 201702229 ISSUED: 06/20/2017
JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018
JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ GLENS CORNING STORM CLASS 4 LAMINATE ASPHALT
SHINGLES - 26 SQ.
is byy, m t signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that i am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
tfiis ermn. i further attest that i am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes. ordinances, regulations, policies and procedures.
?. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the ChiefI3 IIding
Official and may be subject to a fee equal to one-half of the originalpermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Offlccial and is not guaranteed.
4, No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and fnspeetion Services
Division.
6. The issuance or grantin ermit sh'All t b its . ued to be a permit for, or an approval of, any violation of any provision of any
applicable code or an d' -regul t 1 }urisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Inspection time requests will be accepted by email only. Please email requests to insptimerequest(:a,,�ei.wheatridge.co.us
between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.
. r City of Wheat Ridge
Residential Roofing PERMIT - 201702229
PERMIT NO: 201702229 ISSUED: 06/20/2017
JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018
JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT
SHINGLES - 26 SQ.
*** CONTACTS ***
OWNER (303)887-0371 HOOD BEVERLY
GC (303)781-8185 Corey Largen 017636 A to Z Roofing
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 I
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00
FEES
Total Valuation 0.00
Use Tax 201.60
Permit Fee 204.30
** TOTAL ** 405.90
*** COMMENTS ***
*** CONDITIONS ***
EffectivE December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding A'/: -inch exists. Asphalt shingles are required to
be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is
required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturerdt-'s installation
instructions, whichever is more stringent. In order to pass a final inspection of
elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer's technical representative stating that "the application of the roof at
(project address) has been applied in accordance with the installation instruction for
(roof material brand name) roof covering" is required to be on site at the time of"final
inspection.
' City of Wheat Ridge
Residential Roofing PERMIT - 201702229
PERMIT .NO: 201702229 ISSUED: 06/20/2017
JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018
JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT
SHINGLES - 26 SQ.
*** CONTACTS ***
OWNER (303)887-0371 HOOD BEVERLY
GC (303)781-8185 Corey Largen 017636 A to Z Roofing
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00
Total Valuation FEES0.00
Use Tax 201.60
Permit Fee 204.30
** TOTAL ** 405.90
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding k/2 -inch exists. Asphalt shingles are required to
be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is
required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturera€'Ms installation
instructions, whichever is more stringent. In order to pass a final inspection of
elastomeric or similar type roof coverings, a letter of inspection and approval frcm the
manufacturer's technical representative stating that "the application of the roof at
(project address) has been applied in accordance with the installation instruction for
(roof material brand name) roof covering" is required to be on site at the time of"final
inspection.
Avc INSPECTION RECORD
NSPECTION ONLINE FORM: http://www.ci.wheatridge.co.us/forms.aspx?fid=79
INSPECTION REQUEST LINE: (303) 234-5933
Occupa,_ 11 e
Inspections will not be performed unless this card is posted on the project site.
Call the inspection request line before 11:59 p.m. to receive an inspection the following business day.**
Inspector Must Sign ALL Spaces pertinent to this project
Inspector Comments
Foundation Inspections Date Initials
Pier
Concrete Encased Ground (CEG)
Foundation / P.E. Letter
Do Not Pour
Concrete Prior 10 H provai vi ii nt; mwvvw n 15p.c�.�•v• •-�
Underground/Slab Inspections
Date Inspector Comments
Initials
Electrical
Mid -Roof
r
Sewer Service
Lath / Wall Tie
Plumbing
UO Not Gover unser rvunu
Rough Inspections
v' ow"_'vv"el —,a.. -•�••
Date Inspector
Initials
- �� - - -
Comments
Wall Sheathing
Mid -Roof
r
Lath / Wall Tie
Rough Electric "
Rough Plumbing/Gas Line
Rough Mechanical
Rough Framing
Rough Grading
Insulation
_
Drywall Screw / Nail
Date Inspector
Final Inspections Initials
Comments
Landscapi ig & Parking / Planning Dept.
Inspections from these entities should be requested
one week in advance. For landscaping and parking
inspections call 303-235-2846. For ROW and drainage
inspections call 303-235-2861. For fire inspections
contact the Fire Protection District for your project.
ROW &Drainage /Public Works Dept.
Floodplain Inspection (if applicable)
Fire Inspection / Fire Protection Dist.
Final Electrical
Final Plumbing
Final Mechanical
Roof -1
Final Window/Doors
L
Final Building
NOTE: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate
of Occupancy is issued. Approval of the Final Building inspection does not constitute authorization of occupancy.
s.-.-... ♦4..-. Gro n;i +,irt and alPCtrinAl low vnit2n P.
"For how voltage permits - riease uu suic uiai 1Vuy
by the Building Division.
Occupancy Is Not Permitted Until A Certificate of Occupancy Is Issued
Protect This Card From The Weather
A i CITY OF WHEAT RIDGE
__:��Buildin4-inspection DiVMion
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type:
Job Address: 75 af-�
Permit Number:
❑ No one available for inspection.: -Time D �.AM/PMS
Re -Inspection required: Yeso
When corrections have been made, call for re -inspection at 303-234-5933
I /I ;
Date: (0/0 Inspector: )O1-�l' r
DO NOT REMOVE THIS NOTICE
A 4' City of Wheat Ridge
Residential Roofing PERMIT - 201702229
PERMIT NO: 201702229 ISSUED: 06/20/2017
JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018
JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT
SHINGLES - 26 SQ.
*** CONTACTS ***
OWNER (303)887-0371 HOOD BEVERLY
GC (303)781-8185 Corey Largen 017636 A to Z Roofing
*** PARCEL,INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 2408 / FRUITDALE, LEES, STONERIDGE BLOCK/LOT#: 0 /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 9,600.00
FEES
Total Valuation 0.00
Use Tax 201.60
Permit Fee 204.30
** TOTAL ** 405.90 -
*** COMMENTS ***
*** CONDITIONS ***
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) requires an approved inspection
prior to installation of ANY roof coverings and is require on the entire roof when spaced
or board sheathing with ANY gap exceeding A/2 -inch exists. Asphalt shingles are required to
be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is
required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave
and secured in place is required to be provided for all roof inspections. Roof ventilation
is required to comply with applicable codes and/or manufacturer&ems installation
instructions, whichever is more stringent. In order to pass a final inspection of
elastomeric or similar type roof coverings, a letter of inspection and approval from the
manufacturer's technical representative stating that "the application of the roof at
(project address) has been applied in accordance with the installation instruction for
(roof material brand name) roof covering" is required to be on site at the time of final
inspection.
City of Wheat Ridge
Residential Roofing PERMIT - 201702229
PERMIT NO: 201702229 ISSUED: 06/20/2017
JOB ADDRESS: 10675 W 47th AVE EXPIRES: 06/20/2018
JOB DESCRIPTION: RESIDENTIAL RE -ROOF W/ OWENS CORNING STORM CLASS 4 LAMINATE ASPHALT
SHINGLES - 26 SQ.
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable wilding codes, and all applicable municipal codes, policies and procedures, and that 1 am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this perit. I further attest that I am legally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
I . This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Budding
Official and may be subject to a fee equal to one-half of the originalermit fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a change, of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
Inspection time requests will be accepted by email only. Please email requests to insptimerequestgci.wheatridge.co.us
between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line.
Kimberly Cook
From: no-reply@ci.wheatridge.co.us
Sent: Monday, June 12, 2017 12:36 PM
To: Permits CommDev
Subject: Online Form Submittal: Residential Roofing Permit Application
Residential Roofing Permit Application ("I
This application is exclusively for new permits for residential roofs and for licensed
contractors only. This type of permit is ONLY being processed online --do not come
to City Hall to submit an application in person. Permits are processed and issued in
the order they are received. YOU WILL BE CONTACTED WHEN YOUR PERMIT 1
IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME
WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your
contractor's license or insurance has expired, and you may update those
documents at the time you are issued your permit. Permits are currently being
processed within 3-5 business days, subject to change based on volume.
For all other requests:
Homeowners wishing to obtain a roofing permit must apply for the permit in person
at City Hall. Revisions to existing permits (for example, to add redecking) must be
completed in person at City Hall. All other non -roofing permits must be completed in
person at City Hall. The Building Division will be open from 7:30-10:30 a.m.,
Monday through Friday to process these types of requests.
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
REROOFING UNTIL PERMIT HAS BEEN ISSUED.
PROPERTY INFORMATION
Property Address
Property Owner Name
Property Owner Phone
Number
Property Owner Email
Address
Do you have a signed
contract to reroof this
property?
It will need to be
provided at the time of
permit pick-up.
10675 W 47th Ave
Beverly Hood
303-887-0371
Field not completed.
Yes
CONTRACTOR INFORMATION
Contractor Name A to Z Roofing
Contractor's License 017636
Number (for the City of
Wheat Ridge)
Contractor Phone 303-781-8185
Number
Contractor Email Address info@denverroofers.com
(permit pick-up
instructions will be sent
to this email)
Retype Contractor Email info@denverroofers.com
Address
DESCRIPTION OF WORK
Is this application for a Yes
new permit for a
residential roof?
Are you re -decking the No
roof?
Description of Roofing Owens Corning STORM Class 4 laminate
Material
Select Type of Material: Asphalt
If "Other" is selected Field not completed.
above, describe here:
How many squares of the 26
material selected above?
Does any portion of the
property include a flat
roof?
If yes, how many squares
on the flat roof?
No
Field not completed.
TOTAL SQUARES of all 26
roofing material for this
project
2
Provide additional detail
here on the description of
work. (Is this for a house
or garage? What is the
roof pitch? Etc)
Project Value (contract
value or cost of ALL
materials and labor)
4:12, 1 story, ice barrier and new drip metal
•M
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full Yes
responsibility for
compliance with
applicable City of Wheat
Ridge codes and
ordinances for work
under any permit
issued based on this
application.
I understand that this Yes
application is NOT a
permit. I understand I will
be contacted by the City
to pay for and pick up the
permit for this property.
I understand that work Yes
may not begin on this
property until a permit
has been issued and
posted on the property.
I certify that I have been Yes
authorized by the legal
owner of the property to
submit this application
and to perform the work
described above.
Name of Applicant D. Corey Largen
Email not displaying correctly? View it in your browser.
3
Jun 11 1709:23p A to Z Roofing Jimmy Read
pR0 OSAL SUBM17TED T4
BIL LENG ADDRESSS�
9TY, STATE AVD ZPP CODE
a ■EXISTI G TYPE OF ROOF: y
■INST.ALL OR REPLACE WITH: r.ti
■COLOR OF SHINGLE:
■MANUFACTURER'S LIMITED WAR
•EXISTING NUMBER OF LAYERS:
■ROOF PITCH: Z
■ SECTIONS LESS THAN 4/12:
'INSTALL DECKING: 7/16" OSB
INSTALL FELT: 15#
■LNSIALL ICE & WATER SHIELD: YES NO SQ FT _.-
,IME TAL EDGE: 2x2 RAKES 2X4 (120°) EAVES COLOR:!
■ VALLEY TYPE: OPEN
-REPLACE PLUNIBING JACKS;� YES NO :A
RIDGEVENT (LF): J
' Li AR GUARANTEE ON LABOR
■ G rIZED NAILS, 6 PER SHINGLE r
."GUTTERS CLEANED OF ROOFINGDEBRIS
■A TO Z ROOFING TO FURNISH ALL MATERIAL ANP LABOR
a CLEAN UP AND HAUL OFF ALL TRASH FROM ROOF
3038348398 p.4
- . PREFERRED
Co Lon.suU Hoorr.'c Also r:tnTlU r: A''ARTMENT ASS.^,ry IATp4 CQNTUCiOR
h 1 t f
4251 S. Natches Ct. Unit K, Englewood, CO 80110
Phone: 303-781-8185 Fax: 303-781-4875 Qrtif
t.denverroofers,coin
info@denverroofers.com .
PRONE
Dart
106 LOCATION ADDRLSS
CITY, STATE AND ZIP CODE
1 SPECIAL TNSTRUCTIONS
Il �
LG(,S� �t
N — \1
TEAR FF:I N
l
PLYWOOD
-PROTECT LANDSCAPE WHERE NEEDED
,ROLL YARD WITH MAGNETIC ROLLER
■PERNDT FURNISHED BY A TO,Z RO
■ INSURANCE PAPERS PROVIDED: . Nt
Under the tens of this contract the workmandtip warranty is no until payr
An, 11,,rial Wnrnnty is non-tramrferable unlesa otherwise stated by the nvnnufactm
UBC building code requires that lastaners (nails ar staples) MOST penetrate deokine
sheeting. A to Z Hoofing is not ressasible for exposed eaves that nails penetrate.
is made in full A to 7 Roofing is not responsiht: torr driveways or sidewalks that are damaged from vehicles used in nornvl
roo ring procedure. An access fee can be laid by customer to insure heavy>•ehicles will not drive on concrete.
orthickness of A to Z Roofing is not responsible for mold or mildew.
Replacement ofdeteriorated or space decking„ facia boares, ventilators, flashing orother =wrials, unless
otherwise stated in this contract, arc not included and will he charged as an "Ira ons time ani tenterlal basis.
We Propose to furnish all materials and labor complell ed in accordance with the specifications below for the initial sum of:
REPLACEMENT COST: $ per insurance proceeds plus any supplements that may apply to your claim.
Upon approval cf your claim, A TO Z RO FIN will file for any and all supplements which may includo building code ilems, unforeacen items and missed or omitted items on the
insurance scope provided to you by your insurance company. Those items will be paid per your policy provisions and will become part ofthis contract as if contained herein. ATO Z
ROOFING will negotiate a fair and equitable settlement ag:eeable by both your insurance company and A TO Z ROOFING based on competitive market rales for labor & materials with
na additional cost to vary except for your deductible and any upgrades oradditiona I work authorized by you that are not part ofyour approved insurance claim. Should your insurance
company denya full roof replacement, you will not be obligved to this contract and may enter into an acceptable repair agreement with A TO Z ROOFING.
ACCE TANCE Or PROPOSAL— This proposal bcw=E o lees] binning contract 72 ours Earn date of
acceptance- 1 'Jz% per month interest will be added an to a:] accounts 30 days past cne In addition, cost, and
reasonable attorney's fee for collections may be charged on any account past dueowa 0 days_ Payment will
bemade as outlined above. Failure to pay can constitute mechanics tient filed against propery, Cancellation
ofthe contract may be achieved by paying q cancellation fee in the acne ant of5F'a of the contract price. All
returned checks are subject to a returned check charge foe. {{+
Customer is msponsihte for payment as aolliaed in this cc, and payme■1 to q to ZRoofing is not
rontingent upon government irnputirm and !or payment from his or her insuranrc company,
A TO Z ROOFING is owned and operated by 2 IIA� INC.,
a registered Colorado Corporation.
All proposals are subject to approval by Management.
Customer agrees that he or she has read, understood and agreed to
A terms and conditions set forth on the back of this contract
d omerwpp jai Date
Note: ' proposa be yhdrawn by us if not accepted within days
-t r
A Repress aiiv .Approval Dale
A to 7 Roofing.Wnagement Approval Dale
30/ION SIH13AOW3tl ION 00
:aoloadsul if ,1 :a}aa
gE g ;e uoiloadsui-aa aol ileo `apew ueaq aneq suot;oaraoo uagM.
o SOA :paainbaa uoiloadsul-aU
WdV /, auail :uoiloadsui aol algaIiLIna auo oN n
--HLJ M21 El
a �) 0()s::-
N.-.
blo
ee' OL, loe :aagwnN Iivaaad
:ssaappV qor
Q :adA1 uoi}oadsul
30110N N01103dSNI
xeJ 6068-200 (006) • ag1JJ0 5sgz-5sz (000)
mull uo►.loadsul £E69-PEZ (00
uoisinla uolzoodsul 6uippe !� 1
3Jala 1V3HM =10 Alla