Loading...
HomeMy WebLinkAbout7048 W. 28th PlaceCity of Wheat j'iidge MMUNITy DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. F: 303.237.8929 July 22, 2019 Owner/Occupant 7048 W 28t' Place Wheat Ridge, CO 80033 Wheat Ridge, CO 80033-8001 P: 303.235.2855 RE: Previously permitted project plans available for retrieval — Permit 201707721 (New Single Family) Owner/Occupant, This letter is being sent to you because a project for which a permit was issued by the City of Wheat Ridge Building Division and plans and/or other documents were required was recently completed and approved. In accordance with the Building Division's document retention policy, the associated plans and/or other documents are scheduled for disposal. We are writing to offer you an opportunity to retrieve those approved plans and/or documents prior to their disposal by the Building Division. The plans and/or documents are available for retrieval for a period of 20 working days (4 weeks) from the date of this letter — August 19 — and must be retrieved in person at the Building Division offices. This letter must be presented at the time of retrieval of the plans and/or documents. Plans and/or documents available for retrieval CANNOT be mailed and plans and/or documents will NOT be available for retrieval after the expiration of the retrieval period. You may retrieve plans and/or documents between the hours of 7:30 a.m. and 3:30 p.m., Monday through Friday, at the Building Division offices located at 7500 W. 291h Avenue in Wheat Ridge. Cordially, Kimberly Cook Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2873 Fax: 303-237-8929 www.ci.wheatridge.co.us City of Wheat-gie COMMUNITY DEVELOPMENT www.d.wheatridge.co.us CER TIFICA TE OF OCCUPANCY Permit #: 201707721 `� 4' City of Date: 10/26/2018 Wheat�idge COMMUNITY DEVELOPMENT 7500 W 29TH AVE WHEAT RIDGE CO 80033-8001 *Stipulations: New single fami� home - 3,370 sq ft total This certificate verifies that the building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheat Ridge Building Code, Zoning and other related land use and development laws of the City of Wheat Ridge, and may be occupied for the use specified. OWNER: WYTRYKUSZ, KEVIN ADDRESS: 7048 W 28th PI, Wheat Ridge CO 80033 CONTRACTOR/ADDRESS: PROPERTY ADDRESS: 7048 W 28th Pl, Wheat Ridge, CO 80033 PARCEL #: 39-264-12-006 ZONING: R-2 OCCUPANCY: R-3 TYPE OF CONST: V -B OCC LOAD:N/A FOR THE FOLLOWING PURPOSE: Single Familv - New Code Editions: 2012 ICC / 2014 NEC No change shall be made in the Use of this bui: prior notice and a new CERTIFICATE OF OCI from the City of Wheat Ridge Certificate MUST be posted by front door of commercial occupancies Chief Building Official Zoning Administrator A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: q AF Job Address: 701-1ti Permit Number: -d-01-709 ❑ No one available for inspection: Time %? AM/PM Re -Inspection required: Yes ! N0 When corrections have been made, call for re -inspection at 303-234-5933 Date: 10 6/0 Inspector: 3o ! ! i!- DO NOT REMOVE THIS NOTICE 1� i CITY OF WHEAT RIDGE s Bolding Inspection' Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: '305--nvrlp ;dn Job Address: )UL/O G/ 2 -'?4.4 Pl. Permit Number: 20 i 70 X 7 1 t ❑ No one available for inspection: Time A 7PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303 -234 - Date: 1 03-234-Date:1 V? `(/ 10 Inspector: L'V �� DO NOT REMOVE THIS NOTICE TZ Structural Engineering LLC Post Olticc Boa 78, I. Lov Liiid colorado SQ Office, (970) o,3-G016. lax (!+70) December 5, 2017 Kevin Wytrykusz 3801 West 41" Avenue Denver, CO 80211 Footing Observation The Wytrykusz Residence 7048 West 28`x' Place Lot 3, Re -subdivision of Block 2, Mortensen Subdivision Wheat Ridge, CO Project Number: 17-219-31 Dear Mr. Edgington: ,�Zi70-7-3-/ On December 4, 2017, a representative of this office visited the site referenced above to observe the footing form widths, depths, and reinforcement. The continuous footing widths and depths were in general compliance with the foundation drawing by T2 Structural Engineering, project number: 17-219, dated September 21, 2017. The dowel reinforcement was on site and the spacing will be confirmed with the foundation wall observation. Protect freshly placed concrete from temperatures that will compromise the design strength of the concrete. Concrete placement and reinforcement is to be installed in accordance with ACI 318 and IRC. Please contact this office if there are questions, or if additional information is required. Thank you for the opportunity to work with you on this project. Sincerely, Russell T. Zoetewey, Enclosures Inb, am 466il 2 Structural Engineering LLC Post Ot(ice Box y'1 1. veland Colorado,1 005' - o-3 C, l --) 67 Otnce (9 0) (63-60it,. Fax (970)622-9 24 December 13, 2017 Kevin Wytrykusz 3801 West 41St Avenue Denver, CO 80211 Foundation Wall Reinforcement Observation The Wytrykusz Residence 7048 West 28th Place Lot 3, Re -subdivision of Block 2, Mortensen Subdivision Wheat Ridge, CO Project Number: 17-219-32 Dear Mr. Wytrykusz: On December 8, 2017, a representative from this office visited the site referenced above to observe the wall reinforcement size, and location and to confirm the vertical reinforcement spacing in foundation forms. The reinforcement appeared to be in general compliance with the foundation drawing and details by T Structural Engineering, project number: 17-219, dated Sepiember 2 i, '.20 i 7. There was one ufer bar located on the south side of the crawl space foundation wall approximately 2 -feet 6 -inches towards the north from the south face of the crawl space foundation wall. The Ufer bar was tied to the bottom row of continuous rebar in the foundation walls. Protect freshly placed concrete from temperatures that will compromise the design strength of the concrete. Concrete placement and reinforcement is to be installed in accordance with ACI 318 and the IRC. Please contact this office if there are questions, or if additional information is required. Thank you for the opportunity to work with you on this project. Sincerely, �, pPM0 tZ C.�: hJSAN'Tq. 2� f Susan TagJA 3' • • Ar Enclosures Enclosures SjONAL Env mbd, am ,�LCity of -o6rW I eat m —•O COMa1 UNITY DEVELOPMENT 1-7V7'? J--1 City of Wheat Ridge Municipal Building 7500 W. 29' Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIFICATION This form, including the Exhibit on the reverse side, must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This Certification must be submitted for review and approval prior to the placement of concrete and before proceeding with any further construction. DATE: DECEMBER 7, 2017 PERMIT# ADDRESS: 7048 WEST 28TH PLACE, WHEATRIDGE, CO LOT 3 , BLOCK MORTENSEN RESUB, BLOCK 2, BARTH'S SUBDIVISION I hereby certify that the elevation and location of the recently constructed structural foundation for the above property described above has been measured by me or directly under my supervision. The foundation setbacks and elevations for all recently constructed building corners as stated herein have been found by me to be in compliance with all civil engineering and Building Permit construction plans as approved by the City of Wheat Ridge. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: 22.0'(GAR) REAR: 17.0' W SIDE: 6.3' N SIDE: 13.2' S NOTE: ALL DISTANCES ARE WITHIN 2 INCHES OF THOSE ON THE SITE PLAN. The MINIMUM ELEVATION has been determined to be: 5446.3' (NAVD88). The above measurements have been determined on the following location: Check only one): X Top of proposed foundation prior to placement of concrete Top of foundation subsequent to placement of concrete The setback and elevation measurement locations are identified on the attached exhibit. Signed Print 12330'"; loose a's (Surveyor's Seal) CECIL R. CROWE, PE & PLS 12330 Date DEC. 7, 2017 rofessional Surveyor ELECTRONIC SIGNATURE PER TITLE 24-71.3-107 (4) C.R.S. FOR OFFICE USE ONLY Approved by: Inspector Date www.ci.wheatridge.co.as Rev 09117 ! I I (3) 2x6 F 28'- " [ R I _ QF 60 I (3) 2x6 I � 6 P (3) 2x6 r --- C1 - - -- - r----- _-� ---- -- r------ ..- 0..7�� _ _. £fl�s6 _ ! - -- ------------------------- Y --------------------------- — 1 l7 �a (3;2 i f 31 1 N *nmm -- ---- al `('�����+ Client: Kevin Wytrycusz n I Title: The Wytrycusz Residence, Repair Short Beam Post Office Box 7821, Lowiand, Colorado 80,537 Location: 7048 West 28th Place, Wheat Ridge, Colorado Office: (970) 663-601"6, Fax: (970) 622-9324 w-ww.tsguaredengineering.com Date: Sept 26, 2018 1 Job Number: 17-219 1 Sheet: 1 of 1 — -- I I s r- 91 r-.47- - k• I I 14" FTG. 14" G. �'• i P 26 2011!'4 f OF=544 .5' " �J 7110 7 -7 I I s oi� ! I 12" FTG. T0F=544d5' F=5445.56' TOF=544515 B i I 20 FTG. °' 20" FTG. 2x12 blocking 2x12 blockin I I Ex stin = I j v 6x6 column with -111 footing. ' I u AB66 bLSe plate. I , N F ! F I N 1 r----_-- __ Li ! 4 w" I I-- IN --j NA N II ! I I I ro ��I I a I`hic F=5445.56' 2x12 blockin " ( 1 I a G I lease add new ootin s with g xisting footing 20" x 36" x 4 re at 6" 4" minimu I 2x12 blocking I T I I j I i 6" FTG. N _ ! I — ° Refer to Beam Saddle B detail ! ! ! I I (3) 2x6 F 28'- " [ R I _ QF 60 I (3) 2x6 I � 6 P (3) 2x6 r --- C1 - - -- - r----- _-� ---- -- r------ ..- 0..7�� _ _. £fl�s6 _ ! - -- ------------------------- Y --------------------------- — 1 l7 �a (3;2 i f 31 1 N *nmm -- ---- al `('�����+ Client: Kevin Wytrycusz n I Title: The Wytrycusz Residence, Repair Short Beam Post Office Box 7821, Lowiand, Colorado 80,537 Location: 7048 West 28th Place, Wheat Ridge, Colorado Office: (970) 663-601"6, Fax: (970) 622-9324 w-ww.tsguaredengineering.com Date: Sept 26, 2018 1 Job Number: 17-219 1 Sheet: 1 of 1 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECIN NQTIRE. L /C - (r1c� Il r rl dow Inspection Type: 1_1 0 s Fl-/) eNi Vi� le C- 1, Job Address: _70 `/"d W a 4s th P r Permit Number: -do) 7 p -7 7 a) na) Ps rov W1 11 o ul A !.Z h rvj A)) r- Ile 4e i -S s --e ccs , ❑ No one available for inspection: Time 10 = I AM PM Re -Inspection required: Yes 0 When corrections have been made, call for re -inspection at 303-234-5933 Date: / 0 I'd'a Inspector: ► DO NOT REMOVE THIS NOTICE City of Wheatlj ge _OMMUNiTy DEVELOPMENT Escrow/Letter of Credit Transmittal Sheet An escrow has been submitted for the property located at 7048 W. 28t' Place. The escrow is in the amount of one thousand five hundred dollars ($1,500.00). The above amount is to be held in escrow (in G/L Account 01-356) for: ® Planning & Development: landscaping ❑ Public Works: ❑ Other: Escrow expires October 1, 2019 The escrow shall be held by the City as reimbursement to offset cost to City for installation of outstanding improvements. Notes: Name Date City of WheatR dge COMMUNITY DEVELOPMENT Escrow Azreement This agreement made this 181h day of October, 2018, by and between the City of Wheat Ridge and Kevin Wytrykusz for escrow in the amount of one thousand five hundred dollars ($1,500) being held by the City of Wheat Ridge until all outstanding landscape improvements are completed at 7048 W. 28" Place In the event that these improvements are not installed by October 1, 2019, the City of Wheat Ridge or its designee shall have the right to enter upon said property to construct and/or install such improvements or do other such work to accomplish that purpose as may be necessary, provided that the City of Wheat Ridge shall first give notice in writing to the property owner of its intent to do so. If the City of Wheat Ridge exercises its right to perform work of any nature, including labor, materials and use of equipment either by force account or contract, the City shall have the absolute right to withdraw the escrow funds to complete said improvements. The only precondition to the City's right to withdraw the funds for this purpose shall be a letter from the Community Development Director, stating that the improvements have not been completed or provided and that the compliance date of October 1, 2019 has expired. Approved and Agreed: Property Owner k� Signature Print Name Title (if applicable) City of Wheat Ridge, Colorado By: 2U - !N p�LC� IIVI��2 Title: FL PS--Jj E2 Date: `d 1 \,TI Zo 1 s Vv,4,i 2- A-&-, Address ✓U�--T �t 1�G��, Go 50 31 8cn 3 3 Phone Date I i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: y° s F-_ ner i j e c Job Address: -7 a y 8 tv 2 `a - " i`�, ) Permit Number: 2 c i 7 0 7-7 a i �7)nal M e c A Pc, ,4,aI V en -PV r -PI) r-f)ctCP - 0 U-1-5 P asn S 1) P tg 1 �5 Ct ❑ No one available for inspection: Time L/ WPM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: io 4 S 4'g -Inspector: __F L3 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Ll 0 7- t) ;'/v m b to 2 Job Address: -701-/S w o$ th r� 1 Permit Number: 3 01-7 0 -7 -7 a 1 V rllA ❑ No one available for inspection: Time ?z ay &PM Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date:-/ v /j -7 / 8 Inspector: -7--D DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9�Building Inspection 15iV+sion (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTFN NOTICE II L/0"7- nAi PluMb n9 Inspection Type: C1 a S`- Job Address: -7 a L/ 'd Permit Number: '3 d 1-7 e —7 –7 P/v m L f,ng C a A e le_ ❑ No one available for inspection: Time 0! / &PM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303-234-5933 Date:-/ 0 / t, /'3 Inspector: —1-b DO NOT REMOVE THIS NOTICE a 0- i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 1/ F Job Address: 0if a W Permit Number:0.170 % i 1 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes to When corrections have been made, call for re -inspection at 303-234-5933 Date: ,d Inspector: fj > DO NOT REMOVE THIS NOTICE 6 i CITY OF WHEAMRIDGE Building Inspection° Division (303) 234-5933 Inspection line __::��(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 4061— / meta-� Job Address: _�10Y -' ?'i44 �f Permit Number: f' vl7D7 �? Z -'QUI �Zdo 1-o 1,-toJ ❑ No one available for inspection: Time 0'1 5- TOPM Re -Inspection required: Yes (9 When corrections have been made, call for re -inspection at 303-234-5933 Date: 101gi iii Inspector: bane, Coycll DO NOT REMOVE THIS NOTICE e A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: y%%3 F� Job Address: 70?L W -791A A Permit Number: a`D1G 7'7 9 ) 1�a 4 kol;l Ilo r, ❑ No one available for insp n: Time /'��% AM/PM Re -Inspection required: Ye No When corrections have been made, call for re -inspection at 303-234-5933 Date: A 4�lI� Inspector:�r,/ DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection 'Mvision (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: L1 G _ h » 1ill m 6 Job Address: -7 o 44 S w (� ) Permit Number: '? D 1-7 O '7 -7 of ) fr)4:7% ) PIvm leckee l -C SCke dt, tv n C v ❑ No one available for inspection: Time 10=5_9 OPM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303-234-5933 Date: q 2 9 /P9 Inspector: ! i5 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: y0 I - Gas L Job Address: -7 C t1$ w '9 8 �� ) Permit Number: -D a t -7 D 7 -7 a) + jLe o �ac�444qrd -F i ce- Z,t� ❑ No one available for inspection: Time �pm Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303-234-5933 Date: 1 S Inspector: 1 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE �'(303) Building Inspection Division (303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: It:) h u-,-) -e'- P ck v1 Job Address: -7048 U-) Z cF3 Permit Number: 2 0 1-7 0-7 -7 7_ S11 � LPA G! a� � ✓.� �T l - ❑ No one available for inspection: Time 0;-�61 /PM Re -Inspection required: Yes o When corrections have been made, ca I for re -inspection at 303-234-5933 Date: `I' 2 Inspector: bL DO NOT REMOVE THIS NOTICE 0 s CITY OF WHEAT RIDGE - Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE 3P)_ OveL -d Inspection Type: 32 0 - Job Address: -7 0 N 8 w a (rte ) Permit Number: a o I '7 0 `7 -7 a I ❑ No one available for inspection: Time /'a = S9 AM(W Re -Inspection required: Yes @�) When corrections have been made, call for re -inspection at 303-234-5933 Date: &b) bg Inspector: �� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE, / Inspection Type: 30S -ZNj lu • 7/� ��,5 / `�'� Job Address: 7o Permit Number: 14 .• � 1; ❑ No one available for inspection: Time ' " , km, PM Re -Inspection required: Yes "No/ �, When corrections have been made, call for re -inspection at 303-234-5933 Date: �_Inspector:_ JcJi �-�--- DO NOT REMOVE THIS NOTICE i A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line t�om)) (303) 235-2855 Office • (303) 237-8929 Fa }r� ,X_C/ 1 INSPECTION NOTICE Inspection Type: CCS �/ �GS� a�' 3G'/fes?A-/-1 Job Address: C%� Permit Number: t 7 ❑ No one available for inspection: Time l�AM M Re -Inspection required: Yes ( NV ._ When corrections have been made, call for re -inspection at 303-234- ,q 5933 Date: 'L, - f _ Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -310 E fh k Job Address: 7ogg L,/ 9 Permit Number: 20 f 70 7 72-1 ❑ No one available for inspection: me/VLA_J_AM/PM Re -Inspection required: Yes Fo When corrections have been made, call for re -inspection at 303-234- Date:- f l t� Inspector: DO NOT REMOVE THIS NOTICE `/ i CITY OF WHEAT RIDGE �(303) Building Inspection division(303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -31-3- P cU A ;I > / u m Job Address: -701-08 tAi a q Permit Number: X 0 1-7 0 -7 7 2 1 RQ Q!? )LIM ina Gir (-e 01 a • /t r- e C15 h e. 4 iE !Z U i ,1e Air- _�es� 0L ❑ No one available for inspection: Time / Q- / O &PM Re -Inspection required: ( ge No When corrections have been made, call for re -inspection at 303-234-5933 Date: S- 2 S I Inspector: Tf� DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building; Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECT -ION NOTICE Inspection Type: _SO4,- IY1 , j Job Address: ? f- u 8 til a S Permit Number: 2 0/-7 d 7'7 a I Ov +ran, ,�� . ❑ No one available for inspection: Time 11 : V!!' OPM Re -Inspection required: Yes i Vo When corrections have been made, call for re -inspection at 303-234-5933 Date: !9-4/ IInspector: _-T-D DO NOT REMOVE THIS NOTICE 10- la 3 IN i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 c ! - n Job Address: c 41? W a B Permit Number: c 1 7 ® 7 -7 a ❑ No one available for inspection: Time 0: I &PM Re -Inspection required: Zes) No When corrections have been made, call for re -inspection at 303-234-5933 Date: S s 5? Inspector: -ts DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type:. G ) Job Address: 70617 Gly Permit Number: 0/20 772� ❑ No one available for inspection: Time // • �r MM Re -Inspection required: Yes(No When corrections have been made, call for re-inspection/at 3_03-234-5933 Date: �/ ' D - IF Inspector: , )�i%J -i—' DO NOT REMOVE THIS NOTICE G i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3v a 13r" - Job Address: 7o y 6 LJ Permit Number: ' D o J -7 0 `7-7- w ❑ No one available for inspection: Time (.aPM Re -Inspection required: Yes i& When corrections have been made, call for re -inspection at 303-234- Date:----3 03-234-Date:3 193 /4s Inspector: -7-L7 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 704 Permit Number: ��/7o 7V Q No one available for inspection: Time, J- G) AN/PM,% F ate -Inspection ( required: Yes)No 5s e *When corrections have been made, call for re-inspectionat303_-234-5933 Date:%' 1�° f 7 Inspector: DO NOT REMOVE THIS NOTICE /0 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: `2 o S- yl�)un,A .ync��e Job Address: -7a W? w Permit Number: 0 1-7 o -7 -7 a ) ❑ No one available for inspection: Time d z ) !3 AMO Re -Inspection required: Yes 90) When corrections have been made, call for re -inspection at 303-234-5933 Date:-) Inspector: --r-t� DO NOT REMOVE THIS NOTICE `7 A i CITY OF WHEAT RIDGE Building' Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 8 Tt/ Permit Number: a b 1-7 o -77 1 PCA r_t-1 a.' C)+ v 4-o kms, 11 LJNo one available for inspection: Time I I 3 AM! M Re -Inspection required: Ye No When corrections have been made, call for re -inspection at 303 -234 - Date: / D Ll Inspector: T r DO NOT REMOVE THIS NOTICE r - i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION/ NOTICE Inspection Type: Ca • C"/ A Job Address: 7, T AL)OF � G Permit Number: 2zd17®77--2/ ❑ No one available for inspection: Time Alv/PM,) k, moi, s' Re -Inspection required: Yes %P No When corrections have been made, call for re -inspection at 303-234-5933 Date:O/• 23 • ) o9 Inspector: I'VG" 4.&- -- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division 41,)b (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: 7 6 �%�. �!� 27 "` Permit Number:t mile Mo- / / l ❑ No one available for inspection: Time .10. '_.36)AwP Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: /d i , /7 Inspector: )(VAI I DO NOT REMOVE THIS NOTICE T2 Structural O/ ���� Engineering LLC Post Office Box i8°7. Loveland, Colorado SOF?- Otficr(5+.0) 6b3-G07G. December 13, 2017 Kevin Wytrykusz 3801 West 41St Avenue Denver, CO 80211 Foundation Wall Reinforcement Observation The Wytrykusz Residence 7048 West 28th Place Lot 3, Re -subdivision of Block 2, Mortensen Subdivision Wheat Ridge, CO Project Number: 17-219-32 Dear Mr. Wytrykusz: On December 8, 2017, a representative from this office visited the site referenced above to observe the wall reinforcement size, and location and to confirm the vertical reinforcement spacing in foundation forms. The reinforcement appeared to be in general compliance with the foundation drawing and details by T2 Structural Engineering, project number: 17-219, dated September 21, 2017. There was one ufer bar located on the south side of the crawl space foundation wall approximately 2 -feet 6 -inches towards the north from the south face of the crawl space foundation wall. The Ufer bar was tied to the bottom row of continuous rebar in the foundation walls. Protect freshly placed concrete from temperatures that will compromise the design strength of the concrete. Concrete placement and reinforcement is to be installed in accordance with ACI 318 and the IRC. Please contact this office if there are questions, or if additional information is required. Thank you for the opportunity to work with you on this project. Sincerely, �RNDO ti,, c: o Susan Tak?; ct Enclosures '*.S�pNAL EN,v T mbd, am /L, a se,,� 2 Structural-_�/7ll7,, Engineering u c, Post Office Yox ; S2 i, Loveland, Coloi a0,, Office. (970) 663-6016. Pay December 5, 2017 Kevin Wytrykusz 3801 West 41" Avenue Denver, CO 80211 Footing Observation The Wytrykusz Residence 7048 West 28`" Place Lot 3, Re -subdivision of Block 2, Mortensen Subdivision Wheat Ridge, CO Project Number: 17-219-31 Dear Mr. Edgington: On December 4, 2017, a representative of this office visited the site referenced above to observe the footing form widths, depths, and reinforcement. The continuous footing widths and depths were in general compliance with the foundation drawing by T2 Structural Engineering, project number: 17-219, dated September 21, 2017. The dowel reinforcement was on site and the spacing will be confirmed with the foundation wall observation. Protect freshly placed concrete from temperatures that will compromise the design strength of the concrete. Concrete placement and reinforcement is to be installed in accordance with ACI 318 and IRC. Please contact this office if there are questions, or if additional information is required. Thank you for the opportunity to work with you on this project. Sincerely, as v �r Russell T. Zoetewey, 46611 Enclosures -0�''• AU*�F lnb, am o�FSS/ONAL City of Wheat Ridge Single Family - New PERMIT - 201707721 PERMIT NO: 201707721 ISSUED: 11/16/2017 JOB ADDRESS: 7048 W 28th PL EXPIRES: 11/16/2018 JOB DESCRIPTION: New Single Family Dwelling with attached garage: 4 Bedrooms; 601 sq ft Garage; 2,769 sq ft house; 3,370 sq ft total *** CONTACTS *** FEES OWNER (303)319-4041 WYTRYKUSZ, KEVIN Plan Review Fee SUB (720)272-1288 Diego Tellez 120187 L&D Electric LLC SUB (970)372-7438 Thomas Wood 090068 C&F Enterprises SUB (303)995-7955 Joseph Hetherington 110240 MJ Mechanical Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED FEES Total Valuation 0.00 Plan Review Fee 1,641.41 Use Tax 6,634.61 Permit Fee 2,525.25 Engin. Review Fee 150.00 Park Land Dedication 2,497.29 Sidewalk Comm Develo 667.00 ** TOTAL ** 14,115.56 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. PROJECT VALUATION: 315,933.78 As part of the foundation inspection and PRIOR to the placement of concrete and before proceeding with any further construction, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements of the City. Prior to issuance of a CO, 1 tree shall be planted within the front setback. In addition, no less than twenty-five percent (250) of the gross lot area and no less than one hundred percent (1000) of the front yard shall be landscaped. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall Be installed in accordance with the approved landscape plan prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125% of the cost of the installation shall be required. For one- or two-family dwellings, the first twenty-five feet (25') of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. Parkland fees -in -lieu apply. City of Wheat Ridge Single Family - New PERMIT - 201707721 PERMIT NO: 201707721 ISSUED: 11/16/2017 JOB ADDRESS: 7048 W 28th PL EXPIRES: 11/16/2018 JOB DESCRIPTION: New Single Family Dwelling with attached garage: 4 Bedrooms; 601 sq ft Garage; 2,769 sq ft house; 3,370 sq ft total I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this permit. I further attest that I am legally authorized to include al entities named within this document as parties to the work to be performed and th t all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. 11- 4-17 Signature of OWN R or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This. permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made -be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change. of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official " Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of p Wheat K dge COMMUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29th Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: Perm its(a)ci.wheatridge.co.us FOR OFFICE USE ONLY Date: �fZ6j,-1 Plan/Permit # Plan Review Fee: Building Permit Application ZQCw. oto *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: -7040� Vii, 90� Pi-� ' vJt -T T2-0 —, Gv Property Owner (please print): i,' i rJ 'f T(zY IGS Ph 75037--3 (q, 4-r4-1 -- Property Owner Email: ��� 1 �� Y BIZ `� IC US Z �f�tA t L ; C��'►'► Mailing Address: (if different than property address) Address: City, State, Zip: V Co 0 Z l �UILZ;>i>ue-� it = tmr✓,�v1 ��- ���• 4i Arch itec ngineer T2T",r�c Arch ite ngineer'E-mail• Phone: cA-70 ' 4.30 - IU `l, �-(c� t• 4.VG>��Gl ,w ( �r� v�ir Contractor: ��1e / ( 7 Contractors City License #: Phone: 3v 3 Contractor E-mail Address: VCVt t-►y\'fIF-Y �iS2-CU �t"IA- L , &O -M q Ap P �, e,0 r`'T *A /;' Q r k— i n 1, 1' C- t^.- -P ( Gct 2L/7 7. v 1 Sub Contractors: Electrical: it' G Plumbing: G Mechanical: H11, M"AAY 44c W.R. City License # IZot� W.R. City License # W.R. City License # 0go0(v8 Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL OJ RESIDENTIAL Description of work: (Check all that apply) ❑ EW COMMERCIAL STRUCTURE El ELECTRICAL SERVICE UPGRADE VNEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) j.Jt W 4 t+ Z1 L-& fAYYI t t-4 `� 1 I li i 1 1-� ► i �' i ATTA&4P—D &tAV40'60. Sq�Ft LF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: (OWNER(CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Electronic Signature (first and last name): 4��DATE: 2 / DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: --�� ReviewerQV( AP/1- VA C'1 � �-, �0�' BUILDING DEPARTMENT COMMENTS: Reviewer. , va / � j r (� • 3�-)o 6010 (. d2 ` 5qPu -%` � .50C %w j 0A TIDE,P-6-0 -6-0 - I-in,�� —5/1 r-- pill - O �~1 -v7 I W4 /V/27/'7 �T�-,rz AM iL.G 1.1/6p 121(-->jgP 7r_, Building Division Valuation: $ City of LL yOPPAWheat i'(01gle COMMUNITY DEVELOPMENT Official Certification of Property Owner for Non -Trade Specific Permit THIS IS TO CERTIFY that I, the property owner, by my signature, attest that I currently own the project property. I attest I am personally performing all work, without the assistance of hired or professional workers, or, if hiring sub -contractors, have the contractors doing the work listed on the permit. Consultations and inspections will only be performed with the homeowner of record present at the project property. 1 I am the owner and live in the project property. Property Owner(s): Project Property: -70 4-& V\% Project Type: S f' iz- - Notarized signature,,O Applicant State of Colorado } County of 3-e- S'S'ar', } ss The foregoing instrument was acknowledged by me this. _3 rd day of 20 )7 by W'14ry kLsa TAMARA D ODEAN NOTARY PUBLIC STATE OF COLORADO NOTARY ID 20164015481 MY COMMISSION EXPIRES APRIL 22, 2020 My Commission Expires _A/ 22/20 Zb Notary Public RESIDENTIAL Building Permit — Plan Review Worksheet Address: 7 L, I ��� V7� Zoning: -Z Rev. 09/2017 Lot Size: t , 1 �0 PuL �->';,'Sq ft. Lot Width: " �� ,� Rev. 09/2017 Streetscape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots New development ❑ Additions that increase gross floor area (not just the footprint) by 60% or more (proposed floor area — existing floor area ) / existing floor area = % increase If any box above is checked... For SF/DUPLEX—Is there existing ❑ Curb ❑ Gutter L15 -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construction or fees -in -lieu will be required. MULTIFAMILY—Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. Fees -in -lieu of dedication or construction are due at the time the permit is issued. Aacess Conditions (apply to all new driveways, garages, additions, or new homes/units) y For one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer than 25' to any property line, except when used as joint access for two or more lots. J:� In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. R For all uses, one access point per property is permitted. Landscaping Conditions (apply to additions and new dwelling units) ❑ For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. Frontage of lot " - width of driveway _� /70= (round up for required trees) Street trees required: Street trees provided: a0 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. "0'' In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the property owner or contractor once the improvements are in place. Dwelling Unit ❑ Not approved as an independent dwelling unit. City of SINGLE FAMILY/DUPLEX %at " --�c B UILDING PERMIT APP PUB[ IC- wc�aKs LIC,4TION REVIE W Date: Location: 7124e kv , 204 a ATTENTION: BUILDING DIVISION I have reviewed the submitted application documents to construct a AZ5Vi located at the above referenced address. Please note the comments checked below. 1. Drainage: a. Drainage Letter & Plan required: Yes No b. Site drainage/grading plan have been reviewed and are: ZOK X63 �; refer to 2. Public Improvements required & to be completed with project: stipulations. a. street paving/patching: Yes No Completed b. curb & gutter: Yes No Completed c. sidewalk: Yes No Completed d. Other (specify): Yes No Completed For items not constructed, the amount of funds taken in lieu of construction: $ (p(o 3. —K-_ Does all existing roadway/alley R.O.W. meet the standards of the City: --/— Yes No If not, what is required? If R.O.W. is required, has the deed been received: Yes No (see Note below) NOTE: All deeds must be reviewed and approved prior to issuance of the Certificate of Occupancy. 4. APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated requirements and/or attached stipulations. -fes `l'ic. VJ" K /O Signature Mark Van Nattan Date 5. � NOT APPROVED: The Public Works Department has reviewed the submitted material and does not approve this Permit Application for the stated reason(s): Signature Mark Van Nattan Date 7.A Grading Certification Letter from the Engineer -of -Record accompanied by an Improvement Location Certificate (ILC) shall be required prior to the issuance of the Certificate of Occupancy. 8. y NOTE: ANY DAMAGE TO EXISTING PUBLIC IMPROVEMENTS AS A RESULT OF PROJECT CONSTRUCTION SHALL BE REPAIRED PER ROW CONSTRUCTION PERMIT PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. Rev 04/2016 City of Wheat g L091 BLIC WORKS City of Wheat Ridge Municipal Building 7500 W. 20 Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 PUBLIC WORKS DEVELOPMENT REVIEW PEES Date: /0 Z?& //7 Location of Construction: 7Z2413 Purpose of Construction: Single Family _1 Commercial Development Review Processing Fee: .... ........................................... $100.00 (Required of all projects for document processing) Single Family Residence/Duplex Review Fee: ..................................... $50.00 CommerciaUMulti-Familv Review Fees: o Review of existing or minimal technical documents:..... Initial review' of technical civil engineering documents (Fee includes reviews of the 1St and 2nd submittals):....... . Traffic Impact Study Review Fee: st nd $200.00 .................. $600.00 (Fee includes reviews of the 1 and 2 submittals): .......................... $500.00 ® Trip Generation Study Review Fee: .................................................. $200.00 ® O & M Manual Review & SMA Recording Fee ................................ $100.00 Multi -Family i. I,PM // ' Each Application will be reviewed by staff once and returned for changes. If after review of the second submittal changes have not been made to the civil documents or the Traffic Study as requested by staff, further reviews of the Application will be subject to the following Resubmittal Fees: a Resubmittal Fees: 3rd submittal (% initial review fee): .................................................... $300.00 $ 0' submittal (full initial review fee): .................. .............................. $600.00 $ All subsequent submittals: ................................................................. $600.00 g (Full initial review fee) TOTAL REVIEW FEES (due at time of Building Permit issuance): � DD PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE ADDITIONAL LICENSING AND PERMITTING FEES REQUIRED FOR CONSTRUCTION OF IMPROVEMENTS WITHIN PUBLIC RIGHT-OF-WAY. i c6tridgt- oo.us Rev 12/12 City of WheatI i__gc PUBLIC WORKS City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATED: /0 Z2C/ - , ADDRESS: 7�4,g �/. Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 303.235.2864. Sincerely, David F. Brossman, P.L.S. Development Review Engineer CC: File www.ci.wheatridge.co.us Rev 2/08 FEE CALCULATION WORKSHEET Project: Wytrykusz Residence Address: 7048 W. 28th Place Item Description Quantity Unit 1 Excavation & Embankment Item Cost $ 5.98 $ Earthwork — rough grade — 7.5' wide 0.56 SY 0.68 Earthwork — fine grade — 7.5' wide 0.56 SY 2 Reconditioning 23.90 $ Reconditioning & proofrolling — 7.5' wide 0.56 SY 3 Sidewalk Concrete sidewalk — 6" thick and 5' wide 0.56 SY Total cost per linear foot ENTER LENGTH OF FRONTAGE 23 LF Date: 10/26/17 By: MV N Unit Cost Item Cost $ 5.98 $ 3.32 $ 1.23 $ 0.68 $ 1.97 $ 1.09 $ 43.02 $ 23.90 $ 29.00 Cost of sidewalk $ 667.00 Notify applicant, include as a condition of approval, and let permitting know I:\Building Permit Review\2017\7048 W 28th PI\Fee Calculation Worksheet - 7048 Sidewalk.xlsx XNATIC OWNER'S POLICY NORTH AMERICAN TME INSURANCE COMPANY SCHEDULE A NORTH AMERICAN TITLE INSURANCE COMPANY File No: 35100-17-09393 Address Reference: West 28th Avenue - Vacant Land, Wheatridge, CO Amount of Insurance: $200,000.00 Date of Policy: June 20, 2017 at 04:39 PM 1. Name of Insured: Brett A. Robben and Kevin Wytrykusz 2. The estate or interest in the land which is covered by this Policy is: FEESIMPLE 3. Title to the estate or interest in the land is vested in: Brett A. Robben and Kevin Wytrykusz 4. The land referred to in this policy is described as follows: Lot 3, Resubdivision of Block 2, Mortensen Subdivision, County of Jefferson, State of Colorado. NORTH AMERICAN TITLE COMPANY OF COLORADO By: Authorized Officer or Agent ALTA OWNER'S POLICY Schedule A This Policy valid only if Schedule B is attached Policy No.: 35100-17-09393-01 35100-17-09393 cats- ��r hc>at1 id9c CITY OF WHEAT RIDGE BUILDING AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Whcat Ridge, CO 80033-8001 p. 303.235.2855. j. 303.237.8929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: `fi 25'- t7 Project Address: —70 +0 pt'6,C� Name of Firm/Individual submitting documents:IGC, V tri W 'T Project Type/Description: ZN1 S i IGLG'1 VJc� yL �� Signature of Firm Representative or Individual: 11 - rtAm 1 f 1 WLA— , am a duly authorized representative of the agency indicated below and do, by my signature below, hereby acknowledge receipt of documents necessary for review and approval of the project indicated above. � ttS'r3! renrese-- ed. (Please check one) o Wheat Ridge Fire Protection o Arvada Fire Protection o Wheat Ridge Water District Consolidated Mutual Water District a Valley Water District o Denver Water Agency Notes: Ilk (Al o Wheat Ridge Sanitation District o Clear Creek Sanitation District U Fruitdaie Sanitation District o Westridge Sanitation District o Other Signature: 4 Date:t/ o (Agency Representative) k 14 04 W MI.'! IF WHIAT AND 1NI7FCTll^'5!V ICIS I WN I UON A r--.-)py of rill form musl be v=pfelwd by e encV rnalicsied On the PG-M,'t SUbMllaf ti Mill for the project type and be attached to the Budding Perrnd Appy Inn at the bme rif submts�skin. pi Iron prcsenled for ulbMismon wIftul a Complele-d Pr-Dof at Sunm;ssori term (mm a riad agenty wdl nol be acceW.ed or processed, Project Address" Name ntrirm;Individual sut:--nitting docurnerits: tJ LA�F- f V ---� C 7— PrDJECI TypeUesuziptian: 5,f�natwre of Firm RepresenZative at Individs vi ern a purized represenlative of it'd en Y Indcated belov� anT-d(—jF bval Ufa belo; V-� T F t-(; l�hulhiudge rfteApf of doWlIcalls ntcassary fir Mvii w and apprGval nt the pruNct indicated above. ftena Eggresented: (Pluz=e-;ftc,* anal M West Meir a Fire nlemon o Arvada f ire Prolecton * Wh"I Rida Water Pis= * Consolidaled Mutual Water 0*1rict * Valley Water District * Omwer Water Wheat Ridge Sarution Disorct r, Unr Creek Sandatzwk DiZict !P Fruitdale Sanitaon Disiml WeStridge Sanitalion Diw.nut Manual S Compliance Report Job: 9122017 " wrightsi�o , Date: September 14, 2017 Main By: Michael Carson HVAC Consultants 13882 W. 68th Way, Arvada, CO 80004 Phone:303-420-7532 Email: McresiderdialconsLdtarts@gmail.com Web: hvao-residertial-consiltargs.com Projectf f For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.00m Cooling Equipment Design Conditions Outdoor design DB: 90.8°F Sensible gain: 14794 Btuh Entering coil DB: 78.2°F Outdoor design WB: 60.1 °F Latent gain: 0 Btuh Entering coil WB: 62.1'F Indoor design DB: 75.0°F Total gain: 14794 Btuh Indoor RH: 50% Estimated airflow: 968 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Manufacturer: Goodman Mfg. Actual airflow: 968 cfm Sensible capacity: 14794 Btuh Latent capacity: 0 Btuh Total capacity: 14794 Btuh Model: GSX13024+CAPF1824B 100% of load 0% of load 100% of load SHR: Ok% Heating Equipment Design Conditions Outdoor design DB: 3.3°F Heat loss: 24935 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Goodman Mfrg. Actual airflow: 534 cfirn Output capacity: 30720 Btuh Model: GMVC960403BNA 123% of load Meets are all requirements ofACCA Manual S. Entering coil DB: 60.97 Temp. rise: 64 °F Cicl, of Wheat Ridge 2017 -Sep -13 15:27:48 Hgh ' Right-Sute®Urtiversal 201717.0.23 RSU18110 Pagel s\WyV*usz-Robben Residence7048 W 28th Pl.np Calc= MJ8 Front Door faces: E �1 �I2io��� Manual S Compliance Report Job: 9122017 1 t wri Date: September 14, 2017 Upper By: Michael Carson HVAC Consultants 13882 W. 68th Way, Arvada, CO 80004 Phone: 303-420-7532 Email: hvacresideribalconsrltarts@gmail.mm Web: hvac-residential-corsrltarts.com Project • • • For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.com Cooling Equipment Design Conditions design DB: 90.8°F Sensible gain: 13576 Btuh Outdoor design WB: 60.1'F Latent gain: 0 Btuh Indoor design DB: 75.0°F Total gain: 13576 Btuh Indoor RH: 50% Estimated airflow: 841 cfrn Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Goodman Mfg. Model: GSX13024+CAPF1824B Actual airflow: 841 cfrn Sensible capacity: 13576 Btuh 100% of load Latent capacity: 0 Btuh 0% of load Total capacity: 13576 Btuh 100% of load SHR: Ok% Design Conditions Outdoor design DB: 3.3°F Heat loss: 22000 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Goodman Mfg. Actual airflow: 534 chn Output capacity: 30720 Btuh Model: GMVC960403BNA 140% of load Meets are all requirements ofACCA Manual S. wr h - Right-Suto®Uriversa1201717.0.23RSU18110 ...s\Wytrykrsz-RobbenResidence7048W28thP].rLip Calc=MJ8 FrortDoorfaws: E Entering coil DB: 79.9°F Entering coil WB: 62.7°F Entering coil DB: 61.3°F Temp. rise: 64 °F City of Wheat Ridge 3 Page 2 . wrightsoft Component Constructions Main HVAC Consultants 13882 W. 68th Way, Arvada, CO 80004 Phone: 303-420-7532 Email: hvacresidenfialconsUtaMs@gmail.com Web: hvac-residential-constltantss.com Job: 9122017 Date: September 14, 2017 By: Michael Carson Construction descriptions •0,ect intormation area u-valLie For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. Loss Clg HTM Gain 7048 West 28th Place, Wheat Ridge, CO 80033 ft' Btuh/ft;°F ft;°F/Btuh Phone: 303-725-5050 Btuh BtulVft' Btuh Email: mjmechanicalhvac@gmail.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Intl AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 16 Latitude: 40°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 33.4 -33.5 Dry bulb (°F) 3 91 Infiltration: s 357 Daily range (°F) - 27 (H ) Method Simplified 1476 Wet bulb (°F) - 60 Construction quality Average w Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) 4.14 Construction descriptions or area u-valLie Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft;°F ft;°F/Btuh Btuh/f Btuh BtulVft' Btuh Walls Frm wall, stucco ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int n 284 0.062 20.0 4.14 1172 1.15 327 fnsh, 2'x6' wood frm, 16" o.c. stud: Frm wall, stucco ext, 1/2" wood shth, a 210 0.062 20.0 4.14 866 1.15 242 r-20 cav ins, 5/8" gypsum board int fnsh, 2'x6" wood frm, 16" o.c. stud s 357 0.062 20.0 4.14 1476 1.15 412 w 283 0.062 20.0 4.14 1168 1.15 326 all 1133 0.062 20.0 4.14 4683 1.15 1306 Partitions Frm wall, r-20 cav ins, 5/8" gypsum board int fnsh, 2'x6" wood frm, 16" o.c. 92 0.066 20.0 4.40 403 0.57 53 stud: Frm wall, r-20 cav ins, 5/8" gypsum board int fnsh, 2'x6" wood frm, 36 0.066 20.0 2.38 86 0.57 21 16" o.c. stud all 128 0.066 20.0 3.83 488 0.57 73 Windows 2 glazing, droutr, air gas, wd frm mat, dr innr, 1/4" gap, 1/4"thk: 2 glazing, n 45 0.270 0 18.0 810 9.30 418 droutr, air gas, wd frm mat, drinnr, 1/4" gap, 1/4"thk; NFRC rated a 100 0.270 0 18.0 1801 28.8 2881 (SHGC=0.26); 6.67 ft head ht s 138 0.270 0 18.0 2485 14.9 2053 w 34 0.270 0 18.0 612 28.8 979 all 317 0.270 0 18.0 5709 20.0 6332 Doors Door, wd sc type: Door, wd sc type a 28 0.350 0 23.3 654 8.26 231 w 21 0.350 0 23.3 490 8.26 173 n 21 0.350 0 23.3 490 8.26 173 all 70 0.350 0 23.3 1634 8.26 578 Ceilings Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int 146 0.020 49.0 1.33 195 0.94 138 fnsh: Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int fnsh Floors 19A-30bstp: Part floor, tile fir fnsh, r-30 ins, frm flr, 12" thkns 8 0.034 30.0 1.90 15 0.45 3 19C-19cscp: Ar floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav 1303 0.049 30.0 1.13477 0.&? 50 ins, tight crwl ovr, r-11 wall insul City '4 ilii ft0ft" Right -S ite®Urrversal 201717.0.23 RSU18110 s\Wybyktsz-Robben Residence 7048 W 28th Pi.r p Calc= MJ8 Front Door faces: E p,vf� 1 2017 -Sep -1315.27:48 \,guilding Dlvl. 1 wrightsok Component Constructions Upper HVAC Consultants 13882 W. 68th Way,Arvada, CO 80004 Phone: 303-420-7532 Email: h✓acresiderfialcorrLitarts@gmail.com Web: hvao residential-corsutarts.com e-roject intormation For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.com Job: 9122017 Date: September 14, 2017 By: Michael Carson Construction descriptions or Area U -value insul R Htg HTM Loss Cig HTM Gain ft' Btuh/f 2F ft'-°F/Btuh Btuhv Btuh BtuNft' Btuh Walls Frm wall, stucco ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16"o.c. stud: Frm wall, stucco ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2'x6" wood frm, 16" o.c. stud Partitions (none) Windows 2 glazing, droutr, air gas, wd frm mat, drinnr, 1/4" gap, 1/4"thk: 2 glazing, droutr, air gas, wd frm mat, drinnr, 1/4" gap, 1/4"thk; NFRC rated (SHGC=0.26); 6.67 ft head ht Doors (none) Ceilings Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int fnsh: Attic ceiling, asphalt shingles roof mat, r-49 veil ins, 5/8" gypsum board int fnsh Floors 19A-30bswp: Part floor, hrd wd fir fnsh, r-30 ins, fan fir, 12" thkns 19C-19cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav ins, tight crwl ovr, r-11 wall insul n 409 Design s • a 4.14 1689 Location: 471 Indoor: Heating Cooling Denver Stapleton Intl AP, CO, US 813 Indoor temperature (°F) 70 75 Elevation: 5285 ft 20.0 Design TD (°F) 67 16 Latitude: 40°N W 224 Relative humidity (%) 30 50 Outdoor. Heating Cooling Moisture difference (grAb) 33.4 -33.5 Dry bulb (°F) 3 91 Infiltration: 1.15 1364 Daily range (°F) - 27 (H ) Method Simplified Wet bulb (°F) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions or Area U -value insul R Htg HTM Loss Cig HTM Gain ft' Btuh/f 2F ft'-°F/Btuh Btuhv Btuh BtuNft' Btuh Walls Frm wall, stucco ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2"x6" wood frm, 16"o.c. stud: Frm wall, stucco ext, 1/2" wood shth, r-20 cav ins, 5/8" gypsum board int fnsh, 2'x6" wood frm, 16" o.c. stud Partitions (none) Windows 2 glazing, droutr, air gas, wd frm mat, drinnr, 1/4" gap, 1/4"thk: 2 glazing, droutr, air gas, wd frm mat, drinnr, 1/4" gap, 1/4"thk; NFRC rated (SHGC=0.26); 6.67 ft head ht Doors (none) Ceilings Attic ceiling, asphalt shingles roof mat, r-49 ceil ins, 5/8" gypsum board int fnsh: Attic ceiling, asphalt shingles roof mat, r-49 veil ins, 5/8" gypsum board int fnsh Floors 19A-30bswp: Part floor, hrd wd fir fnsh, r-30 ins, fan fir, 12" thkns 19C-19cscp: Flr floor, frm flr, 6" thkns, carpet flr fnsh, r-2 ext ins, r-19 cav ins, tight crwl ovr, r-11 wall insul n 409 0.062 20.0 4.14 1689 1.15 471 e 197 0.062 20.0 4.14 813 1.15 227 s 355 0.062 20.0 4.14 1466 1.15 409 W 224 0.062 20.0 4.14 924 1.15 258 all 1183 0.062 20.0 4.14 4892 1.15 1364 n 49 0.270 0 18.0 873 9.30 451 e 44 0.270 0 18.0 783 28.8 1253 s 86 0.270 0 18.0 1540 14.9 1272 W 30 0.270 0 18.0 531 28.8 850 all 207 0.270 0 18.0 3728 18.5 3826 °moi ' Right-Sute®Universal2017 17.0.23 RSU18110 s\\Nytrykusz-RobbenResiderice7O48W28thPi.rLip Calc= MJ8 Frort Door faces: E 1289 0.020 49.0 1.33 1720 0.94 1214 32 0.034 30.0 1.90 61 0.45 14 92 0.049 30.0 1.13 104 0.27 25 Project Summa Job: 9122017 Wri tso Date: September 14, 2017 Main By. Michael Carson HVAC Consultants 13882 W.68th Way,Arvada, CO 80004 Phone: 303-420-7532 Email: byarresidertialconsiitarts@gmail.com Web: hrar residermal-consriterts.00m For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.com Notes: Information taken from plans dated 8/1/17. Weather: Denver Stapleton Intl AP, CO, US Winter Design Conditions Outside db 3 °F Inside db 70 °F Design TD 67 °F Heating Summary Structure 18719 Btuh Ducts 2482 Btuh Central vent (62 cfm) 3734 Btuh Outside air Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 24935 Btuh Simplified Average 1 (Average) Heating Coolin Area (ft) 1311 1319 Volume (f?) 11799 11799 Air changes/hour 0.38 0.16 Equiv. AVF (cfm) 75 32 Heating Equipment Summary °F Make Goodman Mfrg. H Trade Goodman Relative humidity Model GMVC960403BNA % AHRI ref 8377154 -34 Summer Design Conditions -4 Outside db 91 °F Inside db 75 °F Design TD 16 °F Daily range H 0 Relative humidity 50 % Moisture difference -34 grAb Sensible Cooling Equipment Load Sizing Structure 11131 Btuh Ducts 1072 Btuh Central vent (62 cf-n) 885 Btuh Outside air Blower 1707 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 14794 Btuh Latent Cooling Equipment Load Sizing Structure -4 Btuh Ducts -125 Btuh Central vent (62 cfm) -1160 Btuh Outside air Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 14794 Btuh Req. total capacity at 0.85 SHR 1.5 ton Cooling Equipment Summary Make Goodman Mfg. Trade Goodman Cond GSX13024 Coil CAPF1824B AHRI ref 8377154 Efficiency 96AFUE Efficiency 11.5 EER, 14 SEER Heating input 40000 Btuh Sensible cooling 22200 Btuh Heating output 30720 Btuh Latent cooling 0 Btuh Temperature rise 64 °F Total cooling 22200 Btuh Actual airflow 534 cfrn Actual airflow 968 cfm Air flow factor 0.025 cfrn/Btuh Air flow factor 0.079 cfmBtuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 City of Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Wheat Ridge Wr hft '.R 2017 -Sep- 3 Right-Sute®Uriversa12017 17.0.23 RSU18110 B20 7,Rg �tv1 s\Wytrykrsz-Robben Residence 7048 W 28th PLnp Calc = MJ8 Front Door faces: E Project Summary Job: 9122017 Wri aft Date: September 14, 2017 Upper By: Michael Carson HVAC Consultants 13882 W. 68th Way, Arvada, CO 80004 Phone: 303-420-7532 Email: h✓acresideridalcorsrltarts@gmail.com Web: hvac-residertial-corsLItarts.com For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.com Notes: Information taken from plans dated 8/1/17. Weather: Denver Stapleton Intl AP, CO, US Winter Design Conditions Outside db 3 °F Inside db 70 °F Design TD 67 °F Heating Summary Structure 14696 Btuh Ducts 4516 Btuh Central vent (46 cfm) 2789 Btuh Outside air Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 22000 Btuh Simplified Average 1 (Average) Heating Cooling Area (ft) 1289 1289 Volume (ft') 11486 11486 Airchanges/hour 0.36 0.16 Equiv.AVF (cfm) 69 30 Heating Equipment Summary °F Make Goodman Mfg. H Trade Goodman Relative humidity Model GMVC960403BNA % AHRI ref 8377154 -34 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 96 AFUE 40000 Btuh 30720 Btuh 64 °F 534 Cfm 0.028 cfmBtuh 0.50 in H2O Summer Design Conditions -361 Outside db 91 °F Inside db 75 °F Design TD 16 °F Daily range H 0 Relative humidity 50 % Moisture difference -34 gr/lb Sensible Cooling Equipment Load Sizing Structure 7601 Btuh Ducts 3608 Btuh Central vent (46 cfm) 661 Btuh Outside air Blower 1707 Btuh Use manufacturer's data y Rate/swin multipplier 1.00 Equipmen1sensibleload 13576 Btuh Latent Cooling Equipment Load Sizing Structure -361 Btuh Ducts -105 Btuh Central vent (46 cfm) -866 Btuh Outside air Coil CAPF1824B Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 13576 Btuh Req. total capacity at 0.85 SHR 1.3 ton Cooling Equipment Summary Make Goodman Mfg. Trade Goodman Cond GSX13024 Coil CAPF1824B AHRI ref 8377154 Efficiency 11.5 EER, 14 SEER Sensible cooling 21800 Btuh Latent cooling 0 Btuh Total cooling 21800 Btuh Actual airflow 841 cfm Airflowfactor 0.075 cfmBtuh Static pressure 0.50 in H2O Load sensible heat ratio 1.00 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Wr4g 'it501t Rig ht-Sute®Uriversal 2017 17.0.23 RSU18110 AN ...s\Wytrykusz-Robben Residence 7048 W 28th Pl.rnp Calc = MJ8 Front Door faces: E city of 2017 -Sep -1 P'idge Crawl 24x10 Use Tumi ng Vanes SA'T' and RA top Elbow using a normal elbow at the base of the 20x10 RA Drop. Use inexpensive "see 10x8 through" fitters during the AC season changing monthly. Use low pressure drop pleated fillers during the heating season changing as needed. 6" 6 City 01 "Il, plidge "I Job #: 9122017 6 .. h ScaleA"102 6" 12x8 Page 1 Wytrykusz-Robben Residence 2-13x5.50 5 7048 West 28th Plaoe r 5 ` - Crawl 30x5.50 2017Sep-13 15:28:22 20x8 :, l 1 5" 24x10 Use Tumi ng Vanes SA'T' and RA top Elbow using a normal elbow at the base of the 20x10 RA Drop. Use inexpensive "see 10x8 through" fitters during the AC season changing monthly. Use low pressure drop pleated fillers during the heating season changing as needed. 6" 6 City 01 "Il, plidge "I Job #: 9122017 HVAC Consultants ScaleA"102 Performed by Michael Carson for: Page 1 Wytrykusz-Robben Residence 13882 W 68th Way RightSuiteO Universal 2017 7048 West 28th Plaoe Arvada, CO 80004 17.0.23 RSU18110 Wheat Ridge, CO 80033 Phone: 303-420-7532 2017Sep-13 15:28:22 Phone: 303-7253050 hvac-residentiakonsultants.com hvaaesidentialconsultants@... ...ben Residence 7048 W 28th Pl.rup mjmechanicalhvac@gmail.com 0 2x 29 Main Job #: 9122017 Performed by Michael Carson for: Wytrykusz-Robben Residence 7048 West 28th Place Wheat Ridge, CO 80033 Phone: 303-725-5050 mjmechanicalhvac@gmail.com gmail.com HVAC Consultants 13882 W 68th Way Amada, CO 80004 Phone: 303-420-7532 hvac-residential-consultants.com hvacresidentialconsuttants@... City of Wheat Scale: 1 : 102 Page 2 RightSuite® Universal 2017 17.0.23 RSU18110 2017Sep-13 15:28:22 ...ben Residence 7048 W 28th Pl.rup 4x10 41 ch -n 10x4 87 cfm Upper HVAC Consultants��+S.q2 Uutairs. 40 chn Performed by Michael Carson for: 12x4 Page Wytrykusz-Robben Residence .10x6 13882 W 68th Way 99cfrn Closet Bed 3 " 4X12 Wheat Ridge, CO 80033 20x10 RA Drop with normal Phone: 303-420-7532 Felbowat the base. Use starter 99cfm 7, 158 cftn attic. mjmechanicalhvac@gmaii.com 7" Bed 1 ti 4x1>0 9^ 36cfin a" 12" � Bath 1 6,x 1L1 295 Cfm - 132 ofm ? `p Bed 2 1r„ 7° Lounge 4x10 7. 26 cher �. 14 5„ B�a�th 213 J _ Is" 576 cfm �. 4x10 41 ch -n 10x4 87 cfm city of ont Ridge Job #: 9122017 4x10 HVAC Consultants��+S.q2 Uutairs. 40 chn Performed by Michael Carson for: Page Wytrykusz-Robben Residence .10x6 13882 W 68th Way 1 Laundry '33cfm $„ Bed 3 " 17.0.23 RSU18110 Wheat Ridge, CO 80033 20x10 RA Drop with normal Phone: 303-420-7532 Felbowat the base. Use starter 12x6 off SA and RA plenum in the 158 cftn attic. city of ont Ridge Job #: 9122017 HVAC Consultants��+S.q2 Performed by Michael Carson for: Page Wytrykusz-Robben Residence 13882 W 68th Way Rights life® Universal 2017 7048 West 28th PlaceAmada, CO 80004 17.0.23 RSU18110 Wheat Ridge, CO 80033 Phone: 303-420-7532 2017Sep-13 15:28:22 Phone: 303-725-5050 hvac-residentiakconsuftants.com hvacresidentialoonsultants@... ...ben Residence 7048 W 28th Pl.rup mjmechanicalhvac@gmaii.com . wrightwft Duct System Summary Main HVAC Consultants 13882 W. 68th Way, Arvada, CO 80004 Phone: 303-420-7532 Email: Fnracresider•aloorrltarts@gmail.com Web: hvac-res deitial-constitarft.com Project• i For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.com External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest fri cti on rate Actual airflow Total effective length (TEL) Heating 0.70 in H2O 0.26 in H2O 0.44 in H2O 0.187 /0.253 in H2O 0.071 in/100ft 534 cfm 624 Supply Branch Detail Table Job: 9122017 Date: September 14, 2017 By: Michael Carson Cooling 0.70 in H2O 0.22 in H2O 0.48 in H2O 0.204 /0.276 in H2O 0.077 in/100ft 968 cf1m Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Kitchen C 698 11 55 0.103 5.0 Ox 0 ShMt 28.5 170.0 st2 Kitdien-A c 698 11 55 0.091 5.0 Ox 0 ShMt 33.5 190.0 st2 Living c 1082 52 86 0.084 6.0 Ox 0 ShMt 32.0 210.0 st2A Living -A c 1082 52 86 0.077 6.0 Ox 0 ShMt 45.0 220.0 st2A Living -B c 1082 52 86 0.081 6.0 Ox 0 ShMt 25.5 225.0 st2A aryng c 1003 46 80 0.114 6.0 Ox 0 ShMt 18.5 160.0 st2 Dining -A c 1003 46 80 0.079 6.0 Ox 0 ShMt 27.0 230.0 st2A PVA c 590 22 47 0.102 5.0 Oxo ShMt 34.5 165.0 st2 Mud c 773 50 61 0.099 5.0 Ox 0 ShMt 31.0 175.0 st2 Bath h 1172 30 22 0.102 4.0 Ox 0 ShMt 7.5 175.0 st1 Bed 4 C 954 40 76 0.115 6.0 Ox 0 ShMt 17.0 160.0 st1 Bed 4-A c 954 40 76 0.119 6.0 Ox 0 ShMt 22.0 150.0 SO Foyer c 1002 40 80 0.109 6.0 Ox 0 ShMt 22.5 165.0 st1 Foyer -A c 1002 40 80 0.111 6.0 Ox 0 ShMt 14.5 170.0 st1 Supply Trunk Detail Table City Of Wheat Ridge Vulldingp{jig�p :27:4E WrfOtsoft' Right-Srite®Uriversal 201717.0.23 RSU18110 Page 1 s\Wytrykrsz-RobbenResidence7048W28thPl.rup Calc=MJ8 FrortDoorfaces: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk SO PeakAVF 190 333 0.109 599 9.0 8 x 10 ShtMetl st2 PeakAVF 344 635 0.077 572 12.3 8 x 20 ShtMetl st2A PeakAVF 203 337 0.077 506 9.7 8 x 12 ShtMetl st2 City Of Wheat Ridge Vulldingp{jig�p :27:4E WrfOtsoft' Right-Srite®Uriversal 201717.0.23 RSU18110 Page 1 s\Wytrykrsz-RobbenResidence7048W28thPl.rup Calc=MJ8 FrortDoorfaces: E Return Branch Detail Table Return Trunk Detail Table Name Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct PeakAVF Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mab Trunk rb2 Ox 0 290 494 320.0 0.086 431 10.9 5.50x30 10x33 SJSp rt1 rb5 Ox 0 244 474 358.5 0.077 477 11.0 2-5.50x13 2-10x29 SJSp rt1 Return Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 534 968 0.077 581 14.3 10 x 24 ShtMeb city or ALL rrilatcoft Right-SUte®Uriversal 2017 17.0.23 RSU18110 ...s\Wybykusz-Robben Residence 7048 W 28th Pl.np Calc= MJ8 FrorB Doorfaces: E �s�. Duct System Summary Job: 9122017 wr1 ft7 Rt Date: September 14, 2017 Upper By: Michael Carson HVAC Consultants 13882 W.68th Way,Arvada, C0 80004 Phone:303-420-7532 Email: Ivacresidertbalconsiitarts@gmail.com Web: hvac-residenlial-oonstltarts.com Project! • For: Wytrykusz-Robben Residence, Joe Hetherington/MJ Mechanical Inc. 7048 West 28th Place, Wheat Ridge, CO 80033 Phone: 303-725-5050 Email: mjmechanicalhvac@gmail.com External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.24 in H2O 0.26 in H2O 0.153 /0.107 in H2O 0.079 in/100ft 534 cfm 329 Supply Branch Detail Table Cooling 0.50 in H2O 0.22 in H2O 0.28 in H2O 0.164 /0.116 in H2O 0.085 in/100ft 841 cfm Name Design (Btuh) Htg (dm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mati Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bed 3 c 2106 104 158 0.117 8.0 Ox 0 VIFx 21.0 120.0 PeakAVF Bath 2/3 c 346 21 26 0.138 4.0 Oxo VIFx 4.3 115.0 110 Bed 2 c 1753 82 132 0.132 7.0 Ox 0 VIFx 9.2 115.0 UStairs c 1421 40 40 0.109 5.0 Oxo VIFx 20.3 120.0 Landry c 1776 49 133 0.117 8.0 Ox 0 VIFx 20.0 120.0 Bed 1 c 1314 55 99 0.085 7.0 Ox 0 VIFx 32.9 160.0 st4 Bed 1-A c 1314 55 99 0.087 7.0 Ox 0 VIFx 29.8 160.0 st4 Closet h 1509 42 32 0.086 5.0 Ox 0 VIFx 31.6 145.0 st3 Bath 1 C 1278 36 36 0.091 5.0 Ox 0 VIFx 22.8 145.0 st3 Lounge c 1156 51 87 0.118 7.0 Ox 0 VIFx 19.3 120.0 Supply Trunk Detail Table AIL� 43R 6.ffi 2017 -Sep -131527:48 l6• Rig 201717.0.23 RSU18110 Page 3 ...s\WytnAusz-Robben Residence 7048 W 28th Pl.rtp Calc= MJS Front Door faces: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 77 68 0.086 290 7.0 0 x 0 VInIFIX st4 PeakAVF 110 197 0.085 446 9.0 0 x 0 VInIFIX AIL� 43R 6.ffi 2017 -Sep -131527:48 l6• Rig 201717.0.23 RSU18110 Page 3 ...s\WytnAusz-Robben Residence 7048 W 28th Pl.rtp Calc= MJS Front Door faces: E ALL r - Right-Srite®Uriversal201717.0.23RSU18110 s\Wybykusz-Robben Residence 7048 W 28th Pi.rLp Calc= MJ8 Front Door faces: E Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (efm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk rb4 Ox 0 187 265 98.3 0.118 486 10.0 Ox 0 VIFx rb3 Ox 0 347 576 135.7 0.085 539 14.0 Ox 0 VIFx ALL r - Right-Srite®Uriversal201717.0.23RSU18110 s\Wybykusz-Robben Residence 7048 W 28th Pi.rLp Calc= MJ8 Front Door faces: E COMPLETE ENGINEERING SERVICES, INC. SUBSURFACE INVESTIGATION AND ENGINEERING ANALYSIS PROPOSED SINGLE FAMILY RESIDENCE RI11111111i111 7048 West 28th Place Wheat Ridge, Colorado Prepared For: Mr. Kevin Wytrykusz 3801 W. 41st Ave. Denver, CO 80211 Project No. 17-10633 July 19, 2017 912 TWELFTH STREET, GOLDEN, CO 80401 303 279-6418 FAX: 303-279-9586 TABLE OF CONTENTS SCOPE..............................................................1 PROPOSED CONSTRUCTION................................................1 SITE CONDITIONS......................................................1 SUBSURFACE CONDITIONS................................................2 FOUNDATION DESIGN SPECIFICATIONS.....................................3 DRAIN SYSTEMS......................................................4 FOUNDATION BACKFILL..................................................4 INTERIOR FLOOR SLAB CONSTRUCTION ..................... ..............5 LAWN AND LANDSCAPE IRRIGATION........................................6 INSPECTION AND CONSULTATION..........................................7 FIGURES TEST HOLE LOCATION PLAN.......................................FIGURE 1 TEST HOLE LOGS.......................................................2 SWELL CONSOLIDATION TESTING..........................................3 a SCOPE PROJECT NO. 17-10633 July 19, 2017 Page 1 of 7 A geotechnical and geological engineering investigation was conducted at 7048 West 28th Place, Wheat Ridge, Colorado, to determine foundation design criteria and interior floor system recommendations for a proposed single family residence. Recommendations for design and construction, based on soil and groundwater conditions, are provided. This investigation does not include evaluation of soil or groundwater for the presence of pollutants or other environmental hazards. Conclusions and recommendations presented are based on results of a field and laboratory investigation, other investigations conducted by this firm in the area, and experience with similar projects and conditions. PROPOSED CONSTRUCTION Plans call constructing a new single-family residence. The structure will be two -stories over an approximately four foot deep crawl space. A wood frame superstructure will be supported by a reinforced concrete foundation. SITE CONDITIONS The site is in a fully -developed residential subdivision in Wheat Ridge, Colorado. The surface in the general vicinity slopes to the southeast at gentle to moderate grades. The surface within this lot slopes to the southeast at very gentle to gentle grades. Vegetation consists of shrubs, trees, sod, native grasses and groundcover ants City of typical of landscaped residences and fallow agricultural land in the area. Wheat Ridge Diviso PROJECT NO. 17-10633 July 19, 2017 Page 2 of 7 The only apparent geologic hazard that may affect the proposed construction is shallow groundwater. Recommendations for mitigating this hazard are presented herein. SUBSURFACE CONDITIONS Subsurface conditions were investigated by drilling one foundation design test hole as close as practical to the anticipated building envelope. Approximate test hole location is shown in Figure 1, Test Hole Location Plan. The test hole was drilled to a depth of 20 feet and samples were taken at various intervals based on anticipated foundation bearing depths and materials encountered. Lithologic log and Standard Penetration test results are shown in Figure 2, Test Hole Log. Soils have been deposited by wind and low-energy stream flow. Approximately 18 feet of sandy, soft to medium -stiff clay overlays a medium -grained, medium -dense to dense sand encountered to the total depth investigated. Bedrock was not encountered during drilling operations. Bedrock has been mapped by the U.S.G.S. as the Denver and Arapahoe Formations. The Denver and Arapahoe Formations consist of interbedded sandstones, siltstones, claystones, shales and conglomerates. Bedrock contacts are gradational. Detailed soil and bedrock descriptions are presented in the Test Hole Log on Figure 2. Bedrock will not affect foundation design or performance due to soil depth and groundwater. Swell -consolidation testing was conducted on one representative oilC'tyof sample from a depth of three feet. Test results indicate that t e WheatFidge soils at, and below, foundation bearing depth have low swell suiIdingp�v+sor potential. The soil sample swelled 0.7 percent when saturated and PROJECT NO. 17-10633 July 19, 2017 Page 3 of 7 constant load of 1000 psf. Detailed test results are presented in Figure 3, Swell -Consolidation Test Results. Groundwater was encountered at a depth of eight feet below existing grade during drilling operations. Free water was present at a depth of seven feet below existing grade when checked 16 days after drilling operations. Groundwater appears to be part of a regional perched water table on top of the bedrock. Groundwater depth may vary seasonally and with varying precipitation received during any given period. Future groundwater depth will also be affected by other variables, including: final surface elevation, site drainage and landscape irrigation after development. Measures may be necessary to stabilize the excavation bottom if saturated soils are present at foundation bearing depth. Over - excavation and replacement with three to six -inch -diameter rock driven into the soft soil may be necessary to stabilize foundation support soils. The need for stabilization and appropriate measures can be better evaluated after the excavation is completed. Excavation with a tire -mounted front-end loader may not be possible if saturated soils are encountered. Excavation dewatering may also be required to facilitate foundation construction. Groundwater conditions can be better evaluated during construction by observing the foundation excavation. FOUNDATION DESIGN SPECIFICATIONS The foundation can be supported on continuous spread footings an(W!ding -*NCity of isolated pads designed for a maximum contact pressure of 1500 ps eat Ridge Maximum contact pressure shall be calculated using full dead loaus full 11Ve load. DiviscF, PROJECT NO. 17-10633 July 19, 2017 Page 4 of 7 Footings shall be constructed on relatively undisturbed native soil that is smooth, even and free of organic materials, debris or rocks over three inches in diameter. Footings shall not be constructed on frozen or saturated soils. Soils below anticipated foundation bearing depth are near saturation and soft and may not be suitable for supporting footings. Stabilization measures may be necessary if soft or saturated soils are encountered. Foundation walls shall be designed to withstand an at -rest lateral earth pressure of 60 lb/cu-ft/ft. An equivalent fluid pressure of 250 pcf/ft may be used for passive lateral soil pressures. DRAIN SYSTEMS A foundation drain system is not required for the soils present and the type of construction proposed. Foundation drain system recommendations and specifications can be provided if plans change to include habitable below -grade space. FOUNDATION BACKFILL Backfill placed against foundation walls should be free of trash and fragments of rock over six inches in maximum diameter, moistened and adequately compacted to prevent excessive settlement. Walls should be a minimum of seven days old prior to backfilling. The floor system should be installed or walls should be braced to help prevent movement during backfill operations. Controlled puddling shall not be used. The ground surface shall slope away from the foundation. A minimum grade of 10 percent (one foot in ten) shall be provided within l ee of the structure, or as far as property boundaries permit, whe e t'i'4°f surface is not covered with concrete or other hardscaping. T �w e� idcfo DW PROJECT N0. 17-10633 July 19, 2017 Page 5 of 7 should periodically inspect the surface around the foundation to locate and correct grading problems that may occur due to normal foundation backfill settlement. INTERIOR FLOOR SLAB CONSTRUCTION The builder and/or owner should be aware that concrete floor slabs placed on native soils may move if support materials become wet. Construction of a suspended floor over crawl space is one means of minimizing risk that slab movement will occur. Expansion potential of soils at, and below, garage and interior floor depths indicates there is a low risk of significant interior floor slab movement. The following procedures will help improve slab performance, minimize potential for movement, and help prevent damage if some risk of movement can be tolerated: 1. Subgrade should be prepared based on the soil type encountered. Expansive materials should not be compacted more than necessary during excavation and construction. Clays should not be allowed to dry excessively. The surface should be thoroughly wetted 24 hours prior to slab placement. 2. A minimum four -inch -thick layer of 3/4 -inch washed gravel or crushed rock shall be placed beneath the slab. Rock should be covered with an impervious vapor barrier. A 4 -inch -diameter PVC conduit should be provided through the slab into the gravel layer near the mechanical system to provide for future mechanical ventilation, if necessary. 3. Concrete slabs should be reinforced with steel mesh and should be separated from all bearing members and utilities to allow independent movement ( i.e., a "floating slab"). 4. Joints should be scored in the slab at maximum 200 square foot areas. city of 5. A minimum void space of 2 inches should be constructed abore or below any nonbearing partition walls. In finished areas, anyge furring strips, drywall, paneling, etc., should stop a minimum of 2 inches above the floor. \,RuildingD""' PROJECT NO. 17-10633 July 19, 2017 Page 6 of 7 6. Water pipes should not be placed under the floor slab if hot water is used. A flexible connection should be used to allow some movement between the furnace and the heating ducts if forced -air heating is used. 7. Flexible connections should be used on all mechanical systems placed on floor slabs. All plumbing which extends below floor slabs should have flexible connections and allowance for movement with the slab. 8. Foundation drain systems and landscaping should be completed in strict compliance with specifications contained herein to help prevent wetting of slab support soils. LAWN AND LANDSCAPE IRRIGATION Lawn and landscaping irrigation should be controlled, as much as possible, to prevent additional wetting of subsoils. Automatic sprinkling systems should be placed so that, under full pressure, spray does not fall within five feet of foundation walls. Drip or mist irrigation systems should not be placed within five feet of foundation walls. Installing any portion of the irrigation system within five feet of walls should be avoided. Decorative landscape, such as rock and/or bark should be used in areas next to foundation walls. Vegetation planted within five feet of foundation walls should be hand watered and this watering should be minimized. Downspouts and sillcocks should not be allowed to discharge directly on the ground surface. Splash blocks and/or down spout extensions should be used to discharge water beyond foundation backfill where backfill soils are not covered by pavement and/or sidewalks. The owner is encouraged to read A Guide to SwellingSoils for of o _Homebuyers and Homeowners, Special Publication No. 43, availale fr WY►ea�d9e !ng Dlvison PROJECT NO. 17-10633 July 19, 2017 Page 7 of 7 the Colorado Geological Survey. Recommendations contained in the report are applicable to all residential construction in the Denver area, regardless of soil expansion potential. INSPECTION AND CONSULTATION In any subsurface investigation it is necessary to assume conditions encountered in the field investigation are representative of the site. Actual conditions may differ from anticipated conditions. Subsurface conditions should be verified through visual inspection of the foundation excavation by a representative of this office prior to construction. Footing forms and reinforcing steel placement in foundation walls should also be inspected to insure compliance with these recommendations, engineered foundation plans and City of Wheat Ridge requirements. We are available to discuss the contents of this report with you. Please contact us if you have questions or when further consultation or inspections are required. city of Wheat Ridge Diviso TEST HOLE LOCATION PLAN 7048 WEST 28th PLACE WHEAT RIDGE, COLORADO i I •TH-1 i 01 01 i i WEST 28TH PLACE EXPLANATION OTH-1 FOUNDATION DESIGN TEST HOLE Test holes are located and measured using taping and map measurement. Locations should be considered accurate only to the degree implied by the method used. 30 15 Q 30 SCALE: 1 " = 30' eno Oki o{ PROJECT NO. � 17-10633 COMPLETE ENGINEERING SERVICES FIGUW TEST HOLE LOGS TH-1 0- 11/12 ] s -c +0.7% 5 — ] 4/12 //16/12 EXPLANATION: ® CLAY; sandy, calc., soft to medium stiff, sl. moist to wet, brown, (CL). DSAND; fine to medium grained, white calc. zone above, med. dense to dense, v. moist to wet, brown to orange— brown, (SP). PROJECT NO. 17-10633 20 ]3/13/20 ]13/12 Indicates location of standard penetration S—C test. Indicates 13 blows with a 140 pound 0.0% hammer falling 30 inches were required to drive a 2.5" diameter sampler 12 inches. S—C indicates sample tested for swell— consolidation potential & percent swell (+) or consolidation (—). ]9/12/11 Indicates location of standard penetration test. Indicates number of blows with a 140 Ib. hammer falling 30 inches required to drive 2.0" diameter sampler successive 6" intervals. Indicates approximate location of boundary between lithologic units. Transition may be gradual. _16t Indicates depth to water measured at given number of days after drilling. C:M of �d9e �Nxjeat R 9'j\1Xsoc COMPLETE ENGINEERING SERVICES FIGURE 2 3 0 2 U) z a 1 x w 0 IR 1 2 SWELL- CONSOLIDATION TEST RESULTS MOISTURE CONTENT: 16.0% UNIT DRY WEIGHT: 114.0 pcf DESCRIPTION: Clay, sandy, brn FROM: TH-1 AT 3 FEET I I I I I 1 I I I I I SWELL PRESSURE DD E ER CONSTANT WETTING z 4 O F 0 5 O V) 0 6 U 1.0 10 APPUED PRESSURE (ksf) MOISTURE CONTENT: UNIT DRY WEIGHT: DESCRIPTION: FROM: 0.1 1.0 10 APPLIED PRESSURE (ksf) emmo i PROJECT N0. 17-10632 COMPLETE ENGINEERING SERVICES me 100 ok)[ °{ 3 FIGURE ""r I IV City of Wheat e COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P:303.235.2846 F:303.235.2857 July 7, 2017 OFFICIAL ADDRESS NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: 7048 West 28r' Place, Wheat Ridge, 80033 SUBDIVISION: Mortensen Resub of Blk 2 LOT(s): 3 SECTION: 26 PARCEL NO: 39-264-12-006 NOTES: This is a courtesy notification. AUTHORIZED BY: DATE: to ZO 1^I DISTRIBUTION: 1. Property Owner 2. Jefferson County Assessor, ATTN: Data Control, Lacey Baker email to lbaker(d- jeffco.us 3. Jefferson County Elections, ATTN: H. Roth, 3500 Illinois St., Laramie Building, Suite 1100, Golden, CO 80401 4. Email to Jeffco IT (Mapping) Services at smitchel@jeffco.us and edelynkogjeffco.us 5. Jeffco Public Schools, ATTN: Communication Services, 1829 Denver West Dr., Bldg. 27, Golden, CO 80401 6. U.S. Post Office, 4210 Wadsworth Blvd., Wheat Ridge, CO 80033 7. Email to erlinda.j.martinezAusps.gov and krissy j.summerfield(&usps.gov and arlene.a.vickrey(&usps.gov 8. Xcel Energy, sandra.cardenasOxcelenergy com 9. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 10. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 11. Consolidated Mutual Water Co. 12. Wheat Ridge Sanitation District 13. West Metro Fire District 14. Wheat Ridge Planning Division 15. Wheat Ridge Building Division 16. Wheat Ridge Police Department 17. GIS Specialist 18. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.ci.w h eatridge.co.us DATE: Site Vicinity Map 2835 Reed St a tai•: