Loading...
HomeMy WebLinkAbout3330 Chase Street4 City of �Wheat dge MUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29" Ave. F: 303.237.8929 July 22, 2019 Owner/Occupant 3330 Chase Street Wheat Ridge, CO 80033 Wheat Ridge, CO 80033-8001 P: 303.235.2855 RE: Previously permitted project plans available for retrieval — Permit 201706311 (New Single Family) Owner/Occupant, This letter is being sent to you because a project for which a permit was issued by the City of Wheat Ridge Building Division and plans and/or other documents were required was recently completed and approved. In accordance with the Building Division's document retention policy, the associated plans and/or other documents are scheduled for disposal. We are writing to offer you an opportunity to retrieve those approved plans and/or documents prior to their disposal by the Building Division. The plans and/or documents are available for retrieval for a period of 20 working days (4 weeks) from the date of this letter — August 19 — and must be retrieved in person at the Building Division offices. This letter must be presented at the time of retrieval of the plans and/or documents. Plans and/or documents available for retrieval CANNOT be mailed and plans and/or documents will NOT be available for retrieval after the expiration of the retrieval period. You may retrieve plans and/or documents between the hours of 7:30 a.m. and 3:30 p.m., Monday through Friday, at the Building Division offices located at 7500 W. 29th Avenue in Wheat Ridge. Cordially, Kimberly Cook Permit Technician 7500 W. 29th Avenue Wheat Ridge, Colorado 80033 Office Phone: 303-235-2873 Fax: 303-237-8929 www.ci.wheatrid eg co.us City of WheatWgic COMMUNITY MUNY DEVELOPMENT www.ci.wheatridge.co.us 00 p c OW v, z° Q y oo U bn = o p u � O _ :j O H N O o 3 o O mod r m . ' w oo W r4 r 4.) V ° cc Q.0 O �. tiU +� H a 04.) 4-4 w O m a vim/ o 3 o w w W M o U a) rwi 3 In H q d G cn Q! O a44 O R a) V q r_ o �inld11 9 3 Q 2:,� c� cq U > 0)i .) U o N b�A<Oaa�i oo Q, -,rq a) lei w = o A ❑U�z o'�v d d U 41,1 ° Qm tr b 4.) u w (U 0 v U V o � b �� ti" z w a) •ri 4. o V�L a 3 Qo�a U A c cc M 0. ° 2 0 U a a u M o=a w a A 3 G��AvO N z °'O0 b w Z y L> 6w A a u .+ u F. cn 0 m o fC W y. •ri u= 7 W E■ OW. W Z Z U ro u w H U U N �La 3OCCdO b� °°o a H a� OUac.r�a' LulI I A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: '/05 Ff5 Job Address: 3 3 -3 0 C, h 030 5 � Permit Number: ?-01 7'J� � � ❑ No one available for inspection: Time119 onz AM/PM Re -Inspection required: Yes I O, When corrections have been made, call for re--iinspeccttiion at 303-234-5933 Date: )a/// l Inspector: DO NOT REMOVE THIS NOTICE C �Rt' 4 February, 13 2017 Mann Builders, LLC David Mann 7165 W. 32nd Ave. Wheat Ridge, CO 80033 e3 33 0 Ghase- s W ! 70,6311 CENSPACE, LLC 11332 Oswego Street, Henderson, CO 80640 Phone: (303) 655-9118 Fax (303) 655-9116 www.censpace.com RE: Garage Foundation Reinforcing Inspection Subject Location: 3330 Chase St Wheat Ridge, CO 80033 To Whom It May Concern, CO.6751.01 CENSPACE, LLC inspected the footing and foundation wall reinforcing for the garage at the above referenced location prior to the placing of concrete. We also observed that the UFER was in place at the time of the inspection. It is my opinion that the reinforcing and UFER have been built according to the approved structural plans. These statements represent the opinions of the undersigned based upon the information presented in this report. This report is based upon a relatively short time observation ("snapshot in time") and some of the information may have been supplied by others. Unless specifically noted below this report does not cover electrical, mechanical/plumbing or subsoil conditions including the existence of mold. Since portions of the structure are not available for observation without using destructive methods, CENSPACE, LLC makes no warranty of guarantee, neither implicit nor explicit, that any portion of the contents of this report and/or associated drawings represents the complete or sole solution with respect to hidden defects or unknown conditions. The undersigned believes that the judgments expressed in this report are consistent with that degree of skill and care ordinarily exercised by practicing professionals performing similar design services under similar circumstances. Sincerely, CENSPACE, LLf" Kyle Swartz, P.E. Page 1 of 1 CT 4< ,y-1�� c/N E0_ May 29, 2018 Mann Builders, LLC David Mann 7165 W. 32nd Ave. Wheat Ridge, CO 80033 RE: Framing Inspection Subject Location: 3330 Chase Street Wheat Ridge, CO 80033 To Whom It May Concern, CENSPACE, LLC 11332 Oswego Street, Henderson, CO 80640 Phone: (303) 655-9118 Fax: (303) 655-9116 www.censpace.com CO.6751.01 CENSPACE, LLC inspected the timber framing, pre-engineered trusses and steel framing on May 22nd. It is my opinion that the timber and steel framing have been built according to the approved structural plans. These statements represent the opinions of the undersigned based upon the information presented in this report. This report is based upon a relatively short time observation ("snapshot in time") and some of the information may have been supplied by others. Unless specifically noted below this report does not cover electrical, mechanical/plumbing or subsoil conditions including the existence of mold. Since portions of the structure are not available for observation without using destructive methods, CENSPACE, LLC makes no warranty of guarantee, neither implicit nor explicit, that any portion of the contents of this report and/or associated drawings represents the complete or sole solution with respect to hidden defects or unknown conditions. The undersigned believes that the judgments expressed in this report are consistent with that degree of skill and care ordinarily exercised by practicing professionals performing similar design services under similar circumstances. Sincerely, CENSPACE, LLC ,e¢ 0 O L/C O, 42W1 of Kyle Swartz, P.E. Page I of I ��CTU c/N Et October 16, 2017 Mann Builders, LLC David Mann 7165 W. 32nd Ave. Wheat Ridge, CO 80033 RE: Foundation Reinforcing Inspection Subject Location: 3330 Chase St Wheat Ridge, CO 80033 To Whom It May Concern, CENSPACE, LLC 11332 Oswego Street, Henderson, CO 80640 Phone: (303) 655-9118 Fax (303)655-9116 www.censpace.com CO.6751.00 CENSPACE, LLC inspected the footing and foundation wall reinforcing prior to the placing of concrete on October 13th and October 20th. We also observed that the UFER was in place at the time of the inspection. It is my opinion that the reinforcing and UFER have been built according to the approved structural plans. These statements represent the opinions of the undersigned based upon the information presented in this report. This report is based upon a relatively short time observation ("snapshot in time") and some of the information may have been supplied by others. Unless specifically noted below this report does not cover electrical, mechanical/plumbing or subsoil conditions including the existence of mold. Since portions of the structure are not available for observation without using destructive methods, CENSPACE, LLC makes no warranty of guarantee, neither implicit nor explicit, that any portion of the contents of this report and/or associated drawings represents the complete or sole solution with respect to hidden defects or unknown conditions. The undersigned believes that the judgments expressed in this report are consistent with that degree of skill and care ordinarily exercised by practicing professionals performing similar design services under similar circumstances. Sincerely, CENSPACE, LLC Kyle Swartz, P.E. Page 1 of 1 October 10, 2018 Mann Builders, LLC David Mann 7165 W. 32nd Ave. Wheat Ridge, CO 80033 RE: Isolated Footing Correction Subject Location: 3330 Chase St Wheat Ridge, CO 80033 To Whom It May Concern, CENSPACE, LLC 11332 Oswego Street, Henderson, CO 80640 Phone: (303) 655-9118 Fax: (303) 655-9116 www.censpace.com CO.6751,01 CENSPACE, LLC inspected the isolated footing in crawlspace that was not located properly. It was recommended that the footing be increased in size due to the column being off center. CENSPACE has reviewed the additional size and reinforcing of the added section and found it to be adequate and in conformance with the approved structural plans. These statements represent the opinions of the undersigned based upon the information presented in this report. This report is based upon a relatively short time observation ("snapshot in time") and some of the information may have been supplied by others. Unless specifically noted below this report does not cover electrical, mechanical/plumbing or subsoil conditions including the existence of mold. Since portions of the structure are not available for observation without using destructive methods, CENSPACE, LLC makes no warranty of guarantee, neither implicit nor explicit, that any portion of the contents of this report and/or associated drawings represents the complete or sole solution with respect to hidden defects or unknown conditions. The undersigned believes that the judgments expressed in this report are consistent with that degree of skill and care ordinarily exercised by practicing professionals performing similar design services under similar circumstances. Sincerely, CENSPACE, LLC Kyle Swartz, P.E. Page 1 of 1 The City of Wheat Ridge Third Farty Form Check List i �^ Property Address 33 3D uictsk, Permit Number Permit Issued Date EL _:: Owner Information j Property Owner Information v i AICA /i Property Owner Address '�( V5 n d Inspector Information Inspection Company 6�-r Inspector Name v.��}►'`Q,,-� Inspector Contact info Inspector Statement and Acknowledgement * I hearby acknowledge the roof l am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I Nearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommendations nd specfi tions. Inspector: `_ Date: 31 Z - 1-z Property Owner Statement of Acknowledgement *1 hearty acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ri u 9D inspection. l Propery Owner/Agent: ,�✓ Date: l This original document and permit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date* 7/26/17 r10 ( d r\ Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Mid -Roof Roof Inspection ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Pass ❑ Fail Flashing for roof and walls (] Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A ( Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A F� Pass ❑ Fail Crickets and saddles where needed ❑ N/A D Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A a Pass ❑ Fail Verify vent caps ❑ N/A (] Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A Pass ❑ Fail Underlayments must follow 2012 RRC / 2012 IBC ❑ N/A 1� Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC ❑ N/A Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 ❑ N/A Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ❑ NIA r� PqPass EJFail Above roof insulation R-25 ❑ N/A Pass ❑ Fail Below roof residential R-38 ❑ N/A Q Pass ❑ Fail Below roof commercial R-32 ❑ N/A [ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements ❑ N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements ❑ N/A ❑ Pass ❑ Fail Clay and concrete the shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes Company Name: Inspector signature: Date of Inspection: The City of Wheat Ridge Third Farty Form Check List Property Address3 30 Permit Number Permit issued Date=_ afl�"�' Owner Information Property Owner Information Property Owner Address Inspection Company Inspector Name Inspector Contact info. v a CJS �U /1 t 4C , Inspector Statement and Acknowledgement 1 Nearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6112 must be inspected by the City of Wheat Ridge Buiding Dept, 1 Nearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommenda 'ss an sp!!Ttions. Inspector: 1: J Date: `a L) Property Owner Statement of Acknowledgement *1 hearby acknowledge that 1 am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ri u 9D' inspection. (r/ Propery Owner/Agent: ��--� Date: This original document and permit care , as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 PPT65 Draft Date* 7126/17 y\. o ? Cl o- \ �-- )-.` %'\ \7 Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Final Roof Roof Ins ection ❑ N/A Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A [Pass ❑ Fail Flashing for roof and walls Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) E] N/A Pass E] Fail Verify sheathing nail pattern (See Policy &Procedures) F1N/A Pass F-1Fail Crickets and saddles where needed ❑ N/A '�J Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A D Pass ❑ Fail Verify vent caps ❑ N/A ❑ Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A M Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A '0 Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A ❑ Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A �J Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC ❑ N/A dQ LLI Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 ❑ N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ❑ N/A Pass ❑ Fail Above roof insulation R-25 ❑ N/A a Pass ❑ Fail Below roof residential R-38 ❑ N/A Pass ❑ Fail Below roof commercial R-32 ❑ N/A Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications - Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements ❑ N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements ❑ N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name:-� Inspector signature: �- Date of inspection: s iy tilt ❑ No one available for inspection: Time 1130 AM/PM Re -Inspection required: 4` es No When corrections have been made, call for re -inspection at 303-234-5933 Date: i a o Inspector: f72 DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division �(303) (303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTLON NOT15 L/ Inspection Type: V 7- n aU m i i► �f � �" 1`r Job Address: 33 3 d C Permit Number: G) -7 G 4, 3 1 1 tilt ❑ No one available for inspection: Time 1130 AM/PM Re -Inspection required: 4` es No When corrections have been made, call for re -inspection at 303-234-5933 Date: i a o Inspector: f72 DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division w ; (3Q3),234-5933 Inspection line (303) 235-2855 Office - (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: :0 FT / ---z74 V1 cl) Job Address: '333o C,latS 1p- 31 Permit Number: ❑ No one available for inspection: Time AWPM Re -Inspection required: Yes No When corrections have/been made, 'for re -inspection at 303-234-5933 Date: 1112 ! 15 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE ci o 1- 60-s l 0 ft -e Inspection Type: `-1 D 9 - G Qs nj e -fie, /2& a 6�e Job Address: '375-30 G A A P S Permit Number: a a 1-7 0 (o -3 1 Ga S L ► n v A t!�, P. r) ❑ No one available for inspection: Time '3 = L4 7 Opm Re -Inspection required: Yes (9 When corrections have been made, call for re -inspection at 303-234-5933 Date: 9 J / S Inspector: 1 DO NOT REMOVE THIS NOTICE The City of Wheat Ridge Third Farty Form Check List Property Address j� Permit Number Permit Issued Date Owner Information Property Owner Information Property Owner Address Inspection Company Inspector Name Inspector Contact info VIA 41CA --71 co, � i_� Inspector Statement and Acknowledgement * I hearby acknowledge the roof 1 am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I Nearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommendationsnd specific tions. Inspector: _ llc� %. Date: 31-1-11 j -z Property Owner Statement of Acknowledgement *1 hearty acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ri u g Q inspection. Propery Owner/Agent: `� Dater. This original document and permit card, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7500 W. 29th Ave Wheat Ridge CO 80033 Draft Date, 7/26/17 A a Fur n,, , � c or C 0 d r-, Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Mid -Roof ❑ N/A (] Pass ❑ Fail ❑ N/A Pass ❑ Fail Structural roof components ❑ N/A Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A] Pass ❑ Fail Flashing for roof and walls Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A [ Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A E� Pass ❑ Fail Crickets and saddles where needed ❑ N/A Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A fd Pass ❑ Fail Verify vent caps ❑ N/A � Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A 0 Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A 1� Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A ❑ Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A (iJ, Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A] Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A (tl Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A [� Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC ❑ N/A f -I Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 ❑ N/A Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ❑ N/A Pass ❑ Fail Above roof insulation R-25 ❑ N/A Pass ❑ Fail Below roof residential R-38 ❑ N/A Pass ❑ Fail Below roof commercial R-32 ❑ N/A Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements ❑ N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements ❑ NIA ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes Company Name: Inspector signature: Date of Inspection: The City of Wheat Ridge Third Farty Form Check List Property Address 3 3i `- coal Permit Number Permit Issued Date Owner Information Property Owner Information Property Owner Address Inspection Company Inspector Name Inspector Contact info. v) a AV64 /1 Ape OS3 i _� Inspector Statement and Acknowledgement I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6112 must be inspected by the City of Wheat Ridge Buiding Dept. ' 1 hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's recommends Ws an 1sp ciftaations. Inspector: 1� Z` j paw; �Ll Property Owner Statement of Acknowledgement ,1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ri" g D inspection. Propery Owner/Agent: �" _ Date: = - r t This original document and permit carq, as well as the roofing check list, must be submitted tc the Chief Building Official within seven days of the final inspection. Drop off in person Permit counter 2nd floor 7600 W. 29th Ave Wheat Ridge CO 80033 PPTSS Draft Date, 7/26/17 Please add note to reverse side Roof Inspection ❑ N/A ® Pass ❑ Fail ❑ N/A 'JD Pass ❑ Fail ❑ N/A Q Pass ❑ Fail ❑ N/A LL Pass ❑ Fail Pass ❑ Fail ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A ❑ N/A 71 Pass Pass Pass Pass ❑ Pass j Pass Pass ❑ Pass Pass Pass Pass Pass EL Pass Pass Pass Pass Pass Pass ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail ❑ Fail The City of Wheat Ridge Inspection Check List notes Final Roof Structural roof components Verify that no more than 2 layers of shingles exist Flashing for roof and walls If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) Verify sheathing nail pattern (See Policy & Procedures) Crickets and saddles where needed Verify B vent must have boot same gauge as pipe Verify vent caps Verify no flashings are damaged or rusted Step flashing shall be min. of 4x4 piece per shingle Verify scuppers allow for proper drainage Ice and water shield 2' in heated wall spaces Underlayments must follow 2012 IRC / 2012 IBC Verify roof slope for proper drainage Dripedge shall have min of 2" overlap Dripedge should extend down min 2" past roof deck Dripedge shall be mechanicaly fastened 12" OC 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 Modified Bitumen, EPDM, TPO min slope 1/4:12 slope Above roof insulation R-25 Below roof residential R-38 Below roof commercial R-32 Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications - Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ❑ N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements ❑ N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: S C -►► � � � Inspector signature: Date of Inspection: s �y i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time,) �AM/PM Re -Inspection required: Yes No When corrections have been made, ca I for re -inspection at 303-234-5933 Date: Jt! i Inspector: DO NOT REMOVE THIS NOTICE e CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: "/ -E"S Ao/ (` Job Address: C&5,0. Permit Number: 2-0/70 6 3 / ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303 -234 - Date: r ""/ .� Inspector: DO NOT REMOVE THIS NOTICE 04,le al �-o)9-973 A i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 30/ AF13oq AE 3)3 APA 3)� OR Job Address: 333(3 Lhg5e Permit Number: 2017663 )1 ❑ No one available for inspection: Time J AM/PM r�� Re -Inspection required: J /Yes No E When correcti ns have been ixta e, call for reinspection at 303-234-5933 Date: / Inspector: %� / /! DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax - INSPECTIO NOTICE Inspection Type: 30j R O RC 3/3 /�P% a/6 MA Job Address:. 336 `Uh S>' Permit Number:'/ kj/-(y vp 30) 303 5l 3/6 A lla,y�71 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for rre ,--i7nssppeecjtion at 303 -234- Date: - 03 -234 -Date: �Inspector://- DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE _1�9�Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 c '�; - Job Address: C ,aS:�e Is IL Permit Number: -0 01 71 0(�, 3 1 �(f-2 0l i-okof P - L0 _ d ❑ No one available for inspection: Time = a 3 Igpm Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234-5933 Date: -53c)/,F:r Inspector: 77'J DO NOT REMOVE THIS NOTICE Ll i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 c a /3c.3 - We-, I -t'- S �e Job Address: -3-3 3 0 f )► n Permit Number: 'D a I -7 o 4, 3►) (0=)a ❑ No one available for inspection: Time 9 -- -ol) (P/PM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303-234-5933 Date: __:� aG Inspector: -7--b DO NOT REMOVE THIS NOTICE Ll i CITY OF WHEAT RIDGE _:�9rBuilding Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3 c a /3c.3 - We-, I -t'- S �e Job Address: -3-3 3 0 f )► n Permit Number: 'D a I -7 o 4, 3►) (0=)a ❑ No one available for inspection: Time 9 -- -ol) (P/PM Re -Inspection required: es No When corrections have been made, call for re -inspection at 303-234-5933 Date: __:� aG Inspector: -7--b DO NOT REMOVE THIS NOTICE F + City of W heat f dge COMMUNITY DEVELOPMENT aol-71)&311 City of Wheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 i FOUNDATION SETBACK AND ELEVATION CERTIFICATION This form, including the Exhibit on the reverse side, must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This Certification must be submitted for review and approval prior to the placement of concrete and before proceeding with any further construction. DATE: 10-20-2017 PERMIT# 201706311 ADDRESS: 3330 Chase Street LOT 2, BLOCK , MANN CONSOLIDATION I hereby certify that the elevation and location of the structural foundation for the above property described above has been measured by me or directly under my supervision. The foundation setbacks and elevations for all building corners as stated herein have been found by me to be in compliance with all municipal setback and elevation requirements, and all civil engineering and Building Permit construction plans as approved by the City of Wheat Ridge. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: 27.18' REAR: 56.9' SIDE: 7.05' SIDE: 9.57' The MINIMUM ELEVATION has been determined to be: 5866.32 (NAVD88). The above measurements have been determined on the following location: Check only one): X Top of foundation prior to placement of concrete Top of proposed foundation subsequent to placement of concrete The setback and elevation measurement Signed are identified on the attached exhibit. Print Frank M. 7wolinski Date 10-27-2017 t .�h Professional Surveyor S� A rr. 8 Surveyor's Sea]) 1 FOR OFFICE USE ONLY Approved by: Inspector bate www.cimbeatridge.co.us Rev 12/06 Rev 12/06 EXHIBIT 56.94' F --, �/ a+ 3330 Chase St. PERMIT #201706311 Q� b 27.18 V� J �SJz df ¢� ° a N NOT TO SCALE NOTICE TO SURITYOR: 1. Elevations shall be shown for ALL foundation comers. 2. Foundation comers with minimum elevation and setback distance shall be identified. 3. Drawing must be properly oriented (North = top of page). 4. Show the roadway in front of the property. 5. If drawing is to -scale, provide the scale. If not to -scale show as N.T.S. Rev 12/06 F + City of W heat f dge COMMUNITY DEVELOPMENT aol-71)&311 City of Wheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 i FOUNDATION SETBACK AND ELEVATION CERTIFICATION This form, including the Exhibit on the reverse side, must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This Certification must be submitted for review and approval prior to the placement of concrete and before proceeding with any further construction. DATE: 10-20-2017 PERMIT# 201706311 ADDRESS: 3330 Chase Street LOT 2, BLOCK , MANN CONSOLIDATION I hereby certify that the elevation and location of the structural foundation for the above property described above has been measured by me or directly under my supervision. The foundation setbacks and elevations for all building corners as stated herein have been found by me to be in compliance with all municipal setback and elevation requirements, and all civil engineering and Building Permit construction plans as approved by the City of Wheat Ridge. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: 27.18' REAR: 56.9' SIDE: 7.05' SIDE: 9.57' The MINIMUM ELEVATION has been determined to be: 5866.32 (NAVD88). The above measurements have been determined on the following location: Check only one): X Top of foundation prior to placement of concrete Top of proposed foundation subsequent to placement of concrete The setback and elevation measurement Signed are identified on the attached exhibit. Print Frank M. 7wolinski Date 10-27-2017 t .�h Professional Surveyor S� A rr. 8 Surveyor's Sea]) 1 FOR OFFICE USE ONLY Approved by: Inspector bate www.cimbeatridge.co.us Rev 12/06 Rev 12/06 EXHIBIT 56.94' F --, �/ a+ 3330 Chase St. PERMIT #201706311 Q� b 27.18 V� J �SJz df ¢� ° a N NOT TO SCALE NOTICE TO SURITYOR: 1. Elevations shall be shown for ALL foundation comers. 2. Foundation comers with minimum elevation and setback distance shall be identified. 3. Drawing must be properly oriented (North = top of page). 4. Show the roadway in front of the property. 5. If drawing is to -scale, provide the scale. If not to -scale show as N.T.S. Rev 12/06 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE V)a 11 /P." sk-, J,, . Inspection Type: c - ���• Px'4- Job Address: 3 3o Cg S4 - Permit Number: a 0 7 o G 3) 1 ❑ No one available for inspection: Time Re -Inspection required: Yes (J�( When corrections have been made, call for re -inspection at 303-234-5933 Date: I F /a/1,9 Inspector: DO NOT REMOVE THIS NOTICE 4 a i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: -2y3 5eu1-11 LmV,6A6rovw0 bx-r Job Address:.S,330 C44J'&" 5T Permit Number: 7,491-70&311 ❑ No one available for inspection: Time4T'0r M Re -Inspection required: Yes When corrections have been made, call for re -inspection at 303 -234 - Date: 17 Igz l7 Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3/3- Tt m thel p/_ Job Address: 3 d G R 52, Permit Number: 2O / %O 63 % ❑ No one available for insp tion: Time �%� AM/PM Re -Inspection required:Yes No When corrections have been ma e, call for re -inspection at 303-234-5933 Date: -I()-/4//7 Inspector: )� DO NOT REMOVE THIS NOTICE E r. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax o t INSPECTION NOTICE Inspection Type: 3/� X/�,Q`tea% 4_ Job Address: s S� Permit Number: ❑ No one available for inspection: TiU.No e AI�I%PM Re -Inspection required: Yes When corrections have been made, call for �re-inspection at 303 -234 - Date: /aI //)� / 7 Inspector: DO NOT REMOVE THIS NOTICE R " Q City of Wheat Ridge Single Family - New PERMIT - 201706311 PERMIT NO: 201706311 ISSUED: 09/27/201.7 JOB ADDRESS: 3330 Chase ST EXPIRES: 09/27/2018 JOB DESCRIPTION: New single family homes - 3,100 sq ft *** CONTACTS *** FEES Total Valuation OWNER (812)219-9736 Plan Review Fee DAVID MANN Use Tax 7,161.00 GC (812)219-9736 Engin. Review Fee David J. Mann 150030 Mann Builders LLC SUB (303)862-3810 Bianco Electric 100080 Bianco Electric SUB (970)372-7438 Thomas Wood 090068 C&F Enterprises SUB (303)364-8256 Bryan & Jeremy Gray 120139 Road Runner HVAC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 341,000.00 FEES Total Valuation 0.00 Plan Review Fee 1,746.23 Use Tax 7,161.00 Permit Fee 2,686.50 Engin. Review Fee 150.00 ** TOTAL ** 11,743.73 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. Approved per plans and red -line notes on plans. Must comply with 2012 IRC, 2014 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. As part of the foundation inspection and PRIOR to the placement of concrete and before proceeding with any further construction, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements of the City. Prior to project completion or granting of a Certificate of Occupancy, an As -Built Survey or Improvement Survey Plat shall be submitted to the City. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. For one- or two-family dwellings, the first twenty-five feet (25') of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. ***This project appears to meet these requirements*** Garage is NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. Prior to issuance of a CO, one (1) tree shall be planted within the front setback. In.addition, no less than twenty-five percent (25%) of the gross lot area and no less than one hundred percent (100%) of the front yard shall be landscaped. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall ve installed in accordance with the approved landscape plan prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125% of the cost of the installation shall be required. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications: applica le uildin c and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal o of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this er furthe attest that I am le ally authorized to include all entities named within this document as parties to the work to be per fo ed and t all work to performed is disclosed in this document and/or its' accompanyin approved plans and specifications. S' ure of OWNER or CONTRACTOR (Circle one) Date I. This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdict' royal of work is subject to field inspection. 4Z�774 IL Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 0 City of �Wheat l- dd¢e COMMUNrry DEVELOPMENT Building & Inspection Services Division 7500 W. 291h Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permitsQci.wheatridge.co.us FOR OFFICE USE ONLY Date: � ` J � I —� �+ v Plan/Permit # Plan Review Fee: Building Permit Application *** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. *** Property Address: Property Owner (please Property Owner Email:_ <A C C D1°' Mailing Address: J(if different than property address) Address: (% j �/ `_�>� ✓2 �( City, State, Zip: /` l� �C, Phone 2 1�5c� Grou Arch itectlEngineer E-mail:i-iJ(�3 >7E SSI` Phone:36 1 C _JL2 , (0 Contractor: 1de�S o A4m &,1hjjJ-L ,%. Contractors City License #: V Phone: Contractor E-mail Address: 'C Sub Contractors: Electrical: 91 it (�c�Z Plumbing: (4F W.R. City License # W.R. City License # Other City Licensed Sub: City License # krMechanical: �"�'►'�� 11V"'C� W.R. City License # Other City Licensed Sub: City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL i4ESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE JjrNEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ OTHER (Describe) (For ALL projects, please provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) F J 60 Sq. Ft./LF Jr Q Btu's Amps Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the truthfulness of the information provided on the application. CIRCLE ONE: OWNER (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR) Signature (first and last name): DATE: DEPARTMENT USE ONLY ZONINGCOMMMENTS:-? n 01 F --(C- )G�PCL6,- d- tk,IL< Vbvt v►<. /UPANCY CLASSIFICATION: Reviewer: f�PQ-CAW C�l � BUILDING DEPARTMENT COMMENTS: (-- Reviewer: A0 %�y4Yj� n �--. ` 3 1 Of O�?,1Qp C�6U/ Own PUal-16,' CZ;AAf1r-1lTS: t) p;p-a67` /200F C�24/&/ A-,,- 5PcKW ON MVN q/1//7 C•,-• SlM PI -M 7b PQo-/Vt::;'i AD.)4cE 7- PRCPOR--'iA5s Fra( 5TVA0wa7E;z PL4i dr-. 2� A Lr -77't-:9- y AA10 AN 1[.G AUP acJ�L P� R t'c� - j�' FAC74DP- 71? (,,,D, 7b j5N50PC— Building Division Valuation: $ 1 X4r->1146 . "City of SINGLE FAMILY/DUPLEX I he at , �=-ge R UILDING PERMIT APPLICA TI rta�3t�c WORKS ON REVIEW Date: 1,111T7 Location: 3330 CWAS15 57' ATTENTION: BUILDING DIVISION I have reviewed the submitted application documents to construct a NEW located at the above referenced address. Please note the comments checked below. 1. Drainage: a. Drainage Letter & Plan required: Yes b. Site drainage/grading plan have been reviewed and are: �70K 2. Public Improvements required & to be completed with project: a. street paving/patching: Yes b. curb & gutter: Yes c. sidewalk: Yes d. Other (specify): Yes For items not constructed, the amount of funds taken in lieu of construction 3. --f- Does all existing roadway/alley R.O.W If not, what is required? If R.O.W. is required, has the deed been received: Yes No (see Note below) No No No No No 1111"T,refer to tipulations. Completed Completed Completed Completed meet the standards of the City: Yes No NOTE: All deeds must be reviewed and approved prior to issuance of the Certificate of Occupancy. 4. / APPROVED: The Public Works Department has reviewed the submitted material and hereby approves this Permit Application, subject to the stated requirements and/or attached stipulations. I �A - Signature Mark Van Nattan Date 5. N� NOT APPROVED: The Public Works Department has reviewed the submitted material and does not approve this Permit Application for the stated reason(s): Signature Mark Van Nattan Date • • • F_..Ir 429FE9 78 RW 6-Q'AJ diWZ5 4Si RjW WgQ C RA 22zdn-�N. 7. -A/- A Grading Certification Letter from the Engineer -of -Record accompanied by an Improvement Location Certificate (ILC) shall be required prior to the issuance of the Certificate of Occupancy. 8. NOTE: ANY DAMAGE TO EXISTING PUBLIC IMPROVEMENTS AS A RESULT OF PROJECT CONSTRUCTION SHALL BE REPAIRED PER ROW CONSTRUCTION PERMIT PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. Rev 04/2016 City of PUBLIC WORKS �o City of Wheat Ridge Municipal Building 7500 W. 29'h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 PUBLIC WORKS DEVELOPMENT REVIEW FEES Date: Location of Construction: 3 30 r�r_la Purpose of Construction: 51tJG1. E re AA /1,Y n1d/r= r A1C Single Family 1_ Commercial Multi -Family Development Review Processing Fee: ................... (Required of all projects for document processing) $100.00 Single FamiIv Residence/Duplex Review Fee: .......... ... I ...................... $50.00 Commercial/Multi-Family Review Fees: • Review of existing or minimal technical documents :........................ $200.00 • Initial review' of technical civil engineering documents (Fee includes reviews of the I" and 2nd submittals): .......................... $600.00 • Trak Impact Study Review Fee: (Fee includes reviews of the Is' and 2nd submittals): .......................... $500.00 • Trip Generation Study Review Fee: ............................ ..................... $200.00- 0 200.00- O & M Manual Review & SMA Recording Fee ................................ $100.00 ' Each Application will be reviewed by staff once and returned for changes. If after review of the second submittal changes have not been made to the civil documents or the Traffic Study as requested by staff, further reviews of the Application will be subject to the following Resubmittal Fees: * Resubmittal Fees: 3rd submittal (%2 initial review fee): .................................................... $300.00 $- 4'h submittal (full initial review fee): ................................................. $600.00 $ All subsequent submittals: ........ ........ ............................................... $600.00 $ (Full initial review fee) TOTAL REVIEW FEES (due at time of Building Permit issuance): � p� PLEASE NOTE THAT IN ADDITION TO THE ABOVE FEES, THERE WILL BE ADDITIONAL LICENSING AND PERMITTING FEES REQUIRED FOR CONSTRUCTION OF IMPROVEMENTS WITHIN PUBLIC RIGHT-OF-WAY. www.ci.rvheatridge.co.us Rev 12/12 Oily Of W begat Ri&crc PUIS11C: WORKS City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2861 F: 303.235.2857 NOTIFICATION FOR PUBLIC IMPROVEMENTS RESTORATION DATED: IL ADDRESS: 33 3 0 67,- Dear r- Dear Contractor: In conjunction with the approval of the building permit application for the above referenced address, this letter is to inform you that all existing public improvements located along the frontage of said address shall be restored, (if damaged from related construction) to an acceptable condition, as determined by City of Wheat Ridge Public Works Department, and prior to the issuance of a Certificate of Occupancy. Prior to any construction commencing, the City's representative will conduct an onsite inspection to determine the existing condition(s) of the public improvements at this address. If you have any questions, please contact me at 303.235.2864. Sincerely, David F. Brossman, P.L.S. Development Review Engineer CC: File "'w.d.wheatridge.co.us Rev 2/08 RESIDENTIAL Building Permit — Plan Review Worksheet Address: �'330 CKA-S(� Lot Size: b 17 S 0 Property in the flood plain? ►J sq. ft Zoning: F C Lot Width: 5-0 ft. Rev. 03/2017 If yes, notify PW Floodplain Administrator and add surveying condition FLD Type of project (applicable survey conditions in parenthesis): ❑ Accessory ISP, ILC or site plan none if in floodplain (FLD) J ❑ Addition ILC and site plan if Win 2' of setback or in floodplain (FND) if in floodplain (FLD)__ jd�New ILC and site plan yes (FND if w/in 2' of setbck (NRS if in floodplain (FLD) Maximum Lot Coverage: 40 % Z S o u sq. ft. Exist xis 'ng Improvements: Proposed Improvements: House: sq. ft. House/addition: 1°I sq. ft. Shed: sq. ft. Shed: sq. ft Detached age: sq ft. Detached Garage: Sat g sq. ft. Other: sq. ft. Other: 40 4- 9_5 sq. ft. Total Existing sq. ft Proposed+Existing 2232 sq. ft Lot Coverage % Lot Coverage 36. 2 % q —'Z S S R Required Setbacks: FR c7 S S R Provided Setbacks: FR 2q- S °�� bS R S �µ For additions or new construction, is the structure within 2 feet of minimum setbacks? `i2S If yes, add surveying condition FND. Maximum Height: S ft. Maximum Size: sq. ft. Proposed Height: 32 tdft. Proposed Size: sq. ft. Does the bulk plane apply? (Y/N) If yes, does it meet on all sides (Y/N): FR S Y S R Y (See 26-642 and 26-120.C.1 — applies to all single-family structures (new, addition, accessory) in R -IC and R-3) Parkland Conditions Does the permit result in a new dwelling unit (new structure or conversion from non -res use)? 1d t If yes, have parkland dedication fees already been paid (eg with a previous land use approval)? 0-C C If fees are owed, add condition PFEE, notify owner, notify building division, enter fee amount in ADG. Streetseape Conditions Does the permit result in any of the following conditions? ❑ Construction of new roads ❑ Platting of new lots (d6a j( PwN" �d New development ❑ Additions that increase floor area by 60% or more — use formula: (proposed floor area — existing floor area ) / existing floor area — % inc. If any box above is checked ... (see next page) Rev. 03/2017 For SF/DUPLEX—Is there existing ❑ Curb ❑ Gutterfionor -ft+ sidewalk adjacent to the property? If curb, gutter or sidewalk is missing, streetscape construfees-in-lieu will be required. MULTIFAMILY—Does the frontage meet current city standards? If not, streetscape construction or fees -in -lieu will be required. Fees -in -lieu of dedication or construction are due at the time the permit is issued. Other Conditions acess (applies to all new driveways, garages, additions, or new homes/units) For one and two-family dwellings, the first 25' of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. ❑ For all uses other than one and two family dwellings, no vehicle entrances or exits may be closer N(A than 25' to any property line, except when used as joint access for two or more lots. ❑ In residential zone districts, curb cuts shall be at least 10 feet and not more than 24 feet in width. ❑ One and two-family dwellings may have horseshoe driveways, provided that the street accesses are at least 30 feet apart, measured from the interior edges. l For all uses, one access point per property is permitted. Landscaping (applies to additions and new dwelling units) ❑ For one -and two-family dwellings, one tree for every 70 feet of street frontage is required. Street trees required: I Street trees provided: ,te+ s� ❑ 100% of the front yard and 25% of the entire lot must be landscaped prior to issuance of C.O. ❑ In the event that landscaping cannot be installed due to inclement weather prior to the issuance of a C.O., an escrow agreement with financial guarantees may be allowed to ensure future installation. 125% of the cost of the proposed improvements will be required with the agreement. These funds will be reimbursed back to the property owner or contractor once the improvements are in place. City cif W heat 1is - MY OF WHEAT FJDGE BuI1.DING AND 1NSPEGTION SERVICES DI VISION 7500 W 29th Ave Wheat fudge, CO 80033-8001 p. 303-235.2855.f 303.237.9929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: L I — P - Project Address: Name of Firm/Individual submitting documents: /"'inn t,,A rs L Project Type/Description: e (} O.S C-� R, ( � 6�\ nek1i 0191hw )e— r" 1125 Signature of Firm Representative or Individual: DO NOT WRITE BELOW THIS POINT - FOR AGENCY USE ONLY am a duly authorized representative of the agency indicated below and do, by my signature below, hereby acknowledge receipt of documents necessary for review and approval of the project indicated above. Agency re0resented1: (Please check one) o West (Metro Fire Protection o Arvada Fire Protection o Wheat Ridge Water District o Consolidated MuW Water District o Valley Water District o Denver Water & Wheat Ridge Sanitation District o Clear Greek Sanitation District o Fruitdate Sanitation District Q Westridge Sanitation District o Other Agency Notes: L1�'ASi6 QL&t C 'I"1 �C H E0 V.41" 6—r4 L i—e rt - p l" (LOM f-4 NE{AF47' ArPLsX ShN5-rA-rx AJ DZ.S1'r2�GT Signature: Date- q/ '/(, (Agency A n epi nMa� S P -1 C ity of W heat j isc CITY OF WHEAT RIDGE BUILDING AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033-8001 p. 303.235-2855.f 303.237.8929 Proof of Submission for Permitting/Plan Review A copy of this form must be completed by each agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: r7 Project Address: Name of Firm/Individual submitting documents Project Type/Description: `� `� / CA I/1�_ `'`Ja i ` T�ICS ✓t � fn 1� � � .tet .� !'� L v, ,i � C 1,v� � � I Signature of Firm Representative or Individual: / f' DO NOT WRITE BELOW THIS POINT - FOR AGENCY USE ONLY 'am a duly authorized representative of the agency indicated below and do, by my signature below, hereby acknowledge receipt of documents necessary for review and approval of the project indicated above. Agency represented: (Please check one) o West Metro Fire Protection o Arvada Fire Protection �K Wheat Ridge Water District o Consolidated Mutual Water District o Valley Water District o Denver Water ` �I Agency Notes: 7 1 , - `L (A FZ,6ji�esenta o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other LO w.aeaakr.d„neW0m9nLLC Component Constructions Job: Insul R Htg HTM Entire House Date: Jul 26, 2017 By: David Hardcastle 12 Hardcastle Mechanical Design LLC Plan: 17-029 ft2-°FBtuh 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc0020gmail.com Btuh WNW Btuh Project• • 631 0.068 For: Residential New Construction, Mann Builders 2862 1.26 794 3330 Chase St., Wheat Ridge, CO 80212 367 0.068 19.0 Email: mannbuilders@aol.com 1664 1.26 461 Design Conditions 649 0.068 Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: n 270 Dailyrange (°F) - 27 ( H ) Method Simplified 1171 Wetbulb(°F) - 60 Construction quality Semi -tight 151 Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) 655 Construction descriptions Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 12F-Osw: Frm wall, stucco ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 15B-10s3c-2: Bg wall, light dry soil, concrete wall, r-10 ins, 10" thk Partitions (none) Or Area U -value Insul R Htg HTM Loss Clg HTM Gain 12 ft2 Btuh/ft'-°F ft2-°FBtuh Btu h/W Btuh WNW Btuh n 631 0.068 19.0 4.54 2862 1.26 794 e 367 0.068 19.0 4.54 1664 1.26 461 s 649 0.068 19.0 4.54 2944 1.26 817 w 486 ".C58 19.0 4.54 2205 1.26 612 all 2133 0.068 19.0 4.54 9675 1.26 2683 n 270 0.065 21.0 4.34 1171 1.07 288 e 151 0.065 21.0 4.34 655 1.07 161 s 270 0.065 21.0 4.34 1171 1.07 288 w 115 0.065 21.0 4.34 497 1.07 122 all 806 0.065 21.0 4.34 3493 1.07 859 n 123 0.061 10.0 4.56 561 0.35 43 e 102 0.061 10.0 4.56 465 0.35 35 S 123 0.061 10.0 4.56 561 0.35 43 w 102 0.061 10.0 4.56 465 0.35 35 all 450 0.061 10.0 4.56 2051 0.35 156 Windows U- 2015: 2 glazing, cir outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (3.1 ft window ht, 1 ft sep.); 8 ft head ht U- 2015: 2 glazing, cir outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 e ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht s all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 7 ft head ht 8 0.320 0 21.3 171 9.93 80 12 0.320 0 21.3 248 9.93 115 47 0.320 0 21.3 992 28.5 1324 47 0.320 0 21.3 992 11.9 553 105 0.320 0 21.3 2233 19.0 1992 26 0.320 0 21.3 551 9.93 257 Bold/italic values have been manually overridden + wrightSOft- Right -suite® Universal 2017 17.0.23 RSU18166 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MA Building Front faces: W 2017 -Jul -28 15:06:32 Page 1 U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 8 ft head ht w all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 s ft overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht `I'I w all 4A4-2ovd: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (8 ft window ht, 1 ft sep.); 6.67 ft head ht w all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 7 ft head ht w all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.9 ft window ht, 1 ft sep.); 7 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 8 ft head ht w all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 7 ft head ht Doors 11 D0: Door, wd sc type e w all Ceilings 1613-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh Floors 21A -20t: Bg floor, light dry soil, 2' depth 13 0.320 0 21.3 276 9.93 128 39 0.320 0 21.3 827 28.6 1107 52 0.320 0 21.3 1103 23.9 1235 40 0.320 0 21.3 844 9.93 393 13 0.320 0 21.3 281 12.3 162 10 0.320 0 21.3 218 28.6 292 26 0.320 0 21.3 562 28.6 753 89 0.320 0 21.3 1905 17.9 1599 168 0.470 0 31.3 5267 37.5 6305 48 0.490 0 32.7 1569 22.3 1072 216 0.490 0 31.6 6835 34.2 7377 7 0.320 0 21.3 143 27.8 187 7 0.320 0 21.3 143 27.8 187 13 0.320 0 21.3 287 27.8 373 38 0.320 0 21.3 811 28.5 1084 20 0.320 0 21.3 430 9.93 200 7 0.320 0 21.3 143 27.8 187 27 0.320 0 21.3 573 14.4 387 40 0.320 0 21.3 844 28.6 1130 24 0.390 0 26.0 624 10.8 258 24 0.390 0 26.0 624 10.8 258 48 0.390 0 26.0 1249 10.8 517 114 0.020 50.0 1.33 152 1.02 117 56 0.020 50.0 1.33 75 1.02 57 1053 0.020 50.0 1.33 1405 1.02 1076 1223 0.027 0 1.80 2203 0 0 Bolditalic values have been manually overridden 2017 -Jul -28 15:06:32 44;wrightSoft Right -Suite@ U niv ersal 2017 17.0.23 RSU18166 Page 2 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W H.de.0o.«r> a.i,ntu Component Constructions Job: Date: Jul 26, 2017 AH2 By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Dailyrange (°F) - Wetbulb (°F) - Wind speed (mph) 15.0 Construction descriptions Indoor: Heating Cooling Htg HTM Indoor temperature (°F) 70 75 W Design TD (°F) 67 20 Btuh Btuh/ft= Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: n 323 0.068 27 ( H ) Method Simplified 406 60 Construction quality Semi -tight 19.0 7.5 Fireplaces 1 (Average) s 270 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain w 260 W Btuh/W-T ft2-°F/Btuh Btuh/ftp Btuh Btuh/ft= Btuh Walls 0.068 19.0 4.54 5210 1.26 1445 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 323 0.068 19.0 4.54 1463 1.26 406 fnsh, 2"x6" wood frm, 16" o.c. stud a 253 0.068 19.0 4.54 1147 1.26 318 12F-Osw: Frm wall, stucco ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) s 314 0.068 19.0 4.54 1422 1.26 394 w 260 0.068 19.0 4.54 1178 1.26 327 all 1149 0.068 19.0 4.54 5210 1.26 1445 n 270 0.065 21.0 4.34 1171 1.07 288 e 151 0.065 21.0 4.34 655 1.07 161 s 270 0.065 21.0 4.34 1171 1.07 288 w 115 0.065 21.0 4.34 497 1.07 122 all 806 0.065 21.0 4.34 3493 1.07 859 Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 450, medium; 50% outdoor insect screen; 1.5 e ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht s all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 7 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht 10D -v: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (8 ft window ht, 1 ft sep.); 6.67 ft head ht 12 0.320 0 21.3 248 9.93 115 47 0.320 0 21.3 992 28.5 1324 47 0.320 0 21.3 992 11.9 553 105 0.320 0 21.3 2233 19.0 1992 26 0.320 0 21.3 551 9.93 257 26 0.320 0 21.3 562 28.6 753 48 0.490 0 32.7 1569 22.3 1072 Bold/italic values have been manually overridden City of Wheat Fridge - - 2017-Ju!8�Q4' :32 wrightsof't' Right -Suite@ U niv ersal 2017 17.0.23 RSU18166 ` Page3 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MA Building Front faces: W U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 7 ft head ht w all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.9 ft window ht, 1 ft sep.); 7 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 1613-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 166-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 1613-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh Floors (none) 7 0.320 0 21.3 143 27.8 187 7 0.320 0 21.3 143 27.8 187 13 0.320 0 21.3 287 27.8 373 38 0.320 0 21.3 811 28.5 1084 40 0.320 0 21.3 844 28.6 1130 80 0.020 50.0 1.33 107 1.02 82 56 0.020 50.0 1.33 75 1.02 57 1053 0.020 50.0 1.33 1405 1.02 1076 Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft' Rig ht -Su ite@ U niv ersal 2017 17.0.23 RSU 18166 Page C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W M'scso%O ChWACO0"n LLC Component Constructions Job: Insul R Htg HTM AH 1 Date: Jul 26, 2017 w 226 W By: David Hardcastle ft'-'F/Btuh Btuh/ft2 Hardcastle Mechanical Design LLC Plan: 17-029 Walls 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com 19.0 4.54 4466 Project Information 1239 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int For: Residential New Construction, Mann Builders 19.0 4.54 1399 1.26 3330 Chase St., Wheat Ridge, CO 80212 fnsh, 2"x6" wood frm, 16" o.c. stud a 114 0.068 Email: mannbuilders@aol.com 4.54 517 1.26 143 Design Conditions 0.061 10.0 Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: 31.3 5267 Dailyrange (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain w 226 W Btuh/ftp-°F ft'-'F/Btuh Btuh/ft2 Btuh Btuh/ft2 Btuh Walls 0.068 19.0 4.54 4466 1.26 1239 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 309 0.068 19.0 4.54 1399 1.26 388 fnsh, 2"x6" wood frm, 16" o.c. stud a 114 0.068 19.0 4.54 517 1.26 143 156-10s3c-2: Bg wall, light dry soil, concrete wall, r-10 ins, 10" thk Partitions (none) s 336 0.068 19.0 4.54 1522 1.26 422 w 226 0.068 19.0 4.54 1027 1.26 285 all 985 0.068 19.0 4.54 4466 1.26 1239 n 123 0.061 10.0 4.56 561 0.35 43 e 102 0.061 10.0 4.56 465 0.35 35 s 123 0.061 10.0 4.56 561 0.35 43 w 102 0.061 10.0 4.56 465 0.35 35 all 450 0.061 10.0 4.56 2051 0.35 156 Windows 0.320 U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 9.93 ft overhang (3.1 ft window ht, 1 ft sep.); 8 ft head ht 13 U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 276 ft overhang (5 ft window ht, 1 ft sep.); 8 ft head ht w 39 all U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 s ft overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht w 0.320 all 4A4-2ovd: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 1235 ft overhang (8 ft window ht, 1 ft sep.); 6.67 ft head ht 0.320 8 0.320 0 21.3 171 9.93 80 13 0.320 0 21.3 276 9.93 128 39 0.320 0 21.3 827 28.6 1107 52 0.320 0 21.3 1103 23.9 1235 40 0.320 0 21.3 844 9.93 393 13 0.320 0 21.3 281 12.3 162 10 0.320 0 21.3 218 28.6 292 63 0.320 0 21.3 1343 13.5 846 168 0.470 0 31.3 5267 37.5 6305 Bold/italic values have been manually overridden + wrightsoft, Rig ht -Su ite® U niv ersal 2017 17.0.23 RSU18166 r9l�t� C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W City of Wheat Ridge Page 5 U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s 20 0.320 0 21.3 430 9.93 200 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 8 ft head ht w 7 0.320 0 21.3 143 27.8 187 all 27 0.320 0 21.3 573 14.4 387 Doors 11 D0: Door, wd sc type a 24 0.390 0 26.0 624 10.8 258 w 24 0.390 0 26.0 624 10.8 258 all 48 0.390 0 26.0 1249 10.8 517 Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 34 0.020 50.0 1.33 45 1.02 35 gypsum board int fnsh Floors 21A -20t: Bg floor, light dry soil, 2' depth 1223 0.027 0 1.80 2203 0 0 Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrlghtSOW Right -Suite@ Universal 2017 17.0.23 RSU1 8166 Page C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Nrr4cofew K.0%k iiow D"9ft LLMC Component Constructions Job: Date: Jul 26, 2017 FOYER By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Dailyrange (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 Construction descriptions Indoor: Heating Cooling Insul R Indoor temperature (°F) 70 75 Design TD (°F) 67 20 ft2-°F/Btuh Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 27 ( H ) Method Simplified 0.068 60 Construction quality Semi -tight 74 7.5 Fireplaces 1 (Average) 0.068 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft= Btuh/ft'-°F ft2-°F/Btuh BtuhM Btuh Btuh/ft2 Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int s 59 0.068 19.0 4.54 267 1.26 74 fnsh, 2"x6" wood frm, 16" o.c. stud w 39 0.068 19.0 4.54 177 1.26 49 all 98 0.068 19.0 4.54 444 1.26 123 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s 13 0.320 0 21.3 281 12.3 162 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht Doors 11 DO: Door, wd sc type Ceilings (none) Floors (none) w 24 0.390 Bold/italic values have been manually overridden 0 26.0 624 10.8 258 City of Wheat Ridge 20'�7� J61 -2r$ 7 9108* - wrightsoft, Right -Suite® Universal 2017 17.0.23 RSU18166 e7 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Component Constructions Job: M Date: Jul 26, 2017 STAIR By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft'-°F W-°F/Btuh Btuh/ft' Btuh Btuh/W Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int s 110 0.068 19.0 4.54 500 1.26 139 fnsh, 2"x6" wood frm, 16" o.c. stud w 52 0.068 19.0 4.54 238 1.26 66 all 163 0.068 19.0 4.54 738 1.26 205 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w 13 0.320 0 21.3 276 28.6 369 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 8 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s 7 0.320 0 21.3 143 9.93 67 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 8 ft head ht w 7 0.320 0 21.3 143 27.8 187 all 13 0.320 0 21.3 287 18.9 253 Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSOft' Right -Suite@ U niversal 2017 17.0.23 RSU1 8166 Page C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W wMe�.eMr�s�+,niestp..yntL� Component Constructions Job: Date: Jul 26, 2017 STUDY By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Dailyrange (°F) - Wet bulb (° F) - Wind speed (mph) 15.0 Construction descriptions Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Or Area U -value ft' Btuh/ft'-°F n 77 0.068 w 109 0.068 all 186 0.068 Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 8 ft head ht w all Doors (none) Ceilings (none) Floors (none) Insul R Htg HTM Loss Clg HTM Gain W-°FBtuh Btuh/ftp Btuh Btuh/ft2 Btuh 19.0 4.54 350 1.26 97 19.0 4.54 495 1.26 137 19.0 4.54 845 1.26 234 13 0.320 Indoor: Heating Cooling 9.93 Indoor temperature (°F) 70 75 21.3 Design TD (°F) 67 20 39 0.320 Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 27 ( H ) Method Simplified 60 Construction quality Semi -tight 7.5 Fireplaces 1 (Average) Construction descriptions Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Or Area U -value ft' Btuh/ft'-°F n 77 0.068 w 109 0.068 all 186 0.068 Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 8 ft head ht w all Doors (none) Ceilings (none) Floors (none) Insul R Htg HTM Loss Clg HTM Gain W-°FBtuh Btuh/ftp Btuh Btuh/ft2 Btuh 19.0 4.54 350 1.26 97 19.0 4.54 495 1.26 137 19.0 4.54 845 1.26 234 13 0.320 0 21.3 276 9.93 128 26 0.320 0 21.3 551 28.6 738 39 0.320 0 21.3 827 22.4 866 Bold/italic values have been manually overridden City of Wheat Ri0fnA 2017 -Jul -28 15:06:32 ^� wrightsoft° Right -Suite@ U niversal 2017 17.0.23 RSU1 8166 Page '+ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MA Building Front faces: W Nwkso"""_ftbn 0"n LLC Component Constructions Job: M Date: Jul 26, 2017 PANTRY By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bul b (°F) 3 95 Infiltration: Dailyrange (°F) - 27 ( H ) Method Simplified Wet bulb (OF) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain W Btuh/ft�-°F W-°F/Btuh Btuh/W Btuh BION Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 63 0.068 19.0 4.54 286 1.26 79 fnsh, 2"x6" wood frm, 16" o.c. stud w 26 0.068 19.0 4.54 117 1.26 32 all 89 0.068 19.0 4.54 403 1.26 112 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w 10 0.320 0 21.3 218 28.6 292 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 �^•� wrightSOft' Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 10 ^��^ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Hmk*"* hani"D"i9nLLC Component Constructions Job: Date: Jul 26, 2017 PWDR By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com Project• • For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Dailyrange (°F) - 27 ( H ) Method Simplified Wetbulb(°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/W-T W-°F/Btuh Btuh/ft2 Btuh Btuh/ftp Btuh Walls 12E-osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int in 46 0.068 19.0 4.54 209 1.26 58 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n 8 0.320 0 21.3 171 9.93 80 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (3.1 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden wrlghtSOf ' R ig ht -Su ite@ U niv ersal 2017 17.0.23 RSU 18166 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W City of Wheat Rid 027710 Hudc*a%V*c,•°&'°"i9°LLC Component Constructions Job: Date: Jul 26, 2017 MUD By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com Information --Proi-ect For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W BtuhM2-oF ft2-°F/Btuh BtuhM2 Btuh Btuh/i? Btuh Walls 12E-Osw: Firm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 72 0.068 19.0 4.54 327 1.26 91 fnsh, 2"x6" wood frm, 16" o.c. stud a 30 0.068 19.0 4.54 136 1.26 38 all 102 0.068 19.0 4.54 463 1.26 128 Partitions (none) Windows (none) Doors 11 DO: Door, wd sc type a 24 0.390 0 26.0 624 10.8 258 Ceilings 166-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 6 0.020 50.0 1.33 8 1.02 6 gypsum board int fnsh Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft' Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 12 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W "'°p`9^' Component Constructions Job: Date: Jul 26, 2017 KITCHEN By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ftp Btuh/W-T W-'I'Muh Btuh/W Btuh Btuh/W Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int a 90 0.068 19.0 4.54 408 1.26 113 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 10 0.020 gypsum board int fnsh Floors (none) Bold/italic values have been manually overridden 50.0 1.33 13 1.02 10 2017 -Jul -28 15:06:32 wrightSOW Right-Suite®Universal 2017 17.0.23 RSU1 8166 Page 13 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ftp Btuh/W-T W-'I'Muh Btuh/W Btuh Btuh/W Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int a 90 0.068 19.0 4.54 408 1.26 113 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 10 0.020 gypsum board int fnsh Floors (none) Bold/italic values have been manually overridden 50.0 1.33 13 1.02 10 2017 -Jul -28 15:06:32 wrightSOW Right-Suite®Universal 2017 17.0.23 RSU1 8166 Page 13 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W '.""*t"'""0"LL` Component Constructions Job: Insul R Htg HTM Date: Jul 26, 2017 Gain LIVING By: David Hardcastle W-°F/Muh Btuh/112 Hardcastle Mechanical Design LLC Plan: 17-029 Btuh 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com Project• • For: Residential New Construction, Mann Builders 167 0.068 19.0 3330 Chase St., Wheat Ridge, CO 80212 755 1.26 210 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40'N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified 168 Wetbulb(°F) - 60 Construction quality Semi -tight 5267 Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft'-°F W-°F/Muh Btuh/112 Btuh BtuhN Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int s 167 0.068 19.0 4.54 755 1.26 210 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows 4A4-2ovd: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" a 168 0.470 0 31.3 5267 37.5 6305 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (8 ft window ht, 1 ft sep.); 6.67 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s 13 0.320 0 21.3 287 9.93 133 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 18 0.020 50.0 1.33 24 1.02 18 gypsum board int fnsh Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSOft' Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 14 �ti^ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W NI'U&*0i r.UliHkW Component Constructions Job: U -value Insul R CRAWL Date: Jul 26, 2017 Gain By: David Hardcastle ft� Btuh/W-T Hardcastle Mechanical Design LLC Plan: 17-029 Btuh WNW 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com Walls Project• • For: Residential New Construction, Mann Builders 1513-10s3c-2: Bg wall, light dry soil, concrete wall, r-10 ins, 10" thk n 123 3330 Chase St., Wheat Ridge, CO 80212 10.0 4.56 561 0.35 Email: mannbuilders@aol.com e 102 Design Conditions 10.0 4.56 Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: 0.061 10.0 Dailyrange (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Cig HTM Gain ft� Btuh/W-T ft'-°FBtuh WNW Btuh WNW Btuh Walls 1513-10s3c-2: Bg wall, light dry soil, concrete wall, r-10 ins, 10" thk n 123 0.061 10.0 4.56 561 0.35 43 e 102 0.061 10.0 4.56 465 0.35 35 s 123 0.061 10.0 4.56 561 0.35 43 w 102 0.061 10.0 4.56 465 0.35 35 all 450 0.061 10.0 4.56 2051 0.35 156 Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 21A -20t: Bg floor, light dry soil, 2' depth 1223 0.027 Bold/italic values have been manually overridden 4 + wrightSOtta- Rig ht -Su ite@ U niv ersal 2017 17.0.23 RSU18166 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W 0 1.80 2203 0 0 City of Wheat Rid R"dt. aU.-C"kNt•'a.i9nLLC Component Constructions STAIR2 Hardcastle Mechanical Design LLC 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc0020gmail.com Job: Date: Jul 26, 2017 By: David Hardcastle Plan: 17-029 Area Project Information Insul R Htg HTM For: Residential New Construction, Mann Builders 0.320 0 ft' 3330 Chase St., Wheat Ridge, CO 80212 ft'-°F/Btuh Btuh/ft= Btuh Btuh/ft� Email: mannbuilders@aol.com Walls Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: 0.068 19.0 Daily range (°F) - 27 ( H ) Method Simplified Wetbulb(°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Cig HTM Gain 0.320 0 ft' Btuh/W-°F ft'-°F/Btuh Btuh/ft= Btuh Btuh/ft� Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int s 105 0.068 19.0 4.54 478 1.26 133 fnsh, 2"x6" wood frm, 16" o.c. stud w 59 0.068 19.0 4.54 267 1.26 74 all 164 0.068 19.0 4.54 745 1.26 207 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 It sep.); 7 ft head ht Doors (none) Ceilings 1613-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh Floors (none) 12 0.320 0 21.3 248 11.9 138 13 0.320 0 21.3 281 28.6 377 64 0.020 50.0 1.33 85 1.02 65 Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 At�_ wrightSOft• Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 16 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W w. ...4ftwotvV"^►u Component Constructions Job: U -value Insul R MASTER Date: Jul 26, 2017 By: David Hardcastle Gain Hardcastle Mechanical Design LLC Plan: 17-029 W 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com ft'-°F/Btuh Btuh/ftp Btuh Project • • Btuh Walls For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int Email: mannbuilders@aol.com 91 0.068 19.0 Design Conditions 413 1.26 Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Dailyrange (°F) - 27 ( H ) Method Simplified Wetbulb(°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/fly-°F ft'-°F/Btuh Btuh/ftp Btuh Btuh/ft2 Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 91 0.068 19.0 4.54 413 1.26 115 fnsh, 2"x6" wood frm, 16" o.c. stud w 109 0.068 19.0 4.54 493 1.26 137 all 200 0.068 19.0 4.54 906 1.26 251 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n 26 0.320 0 21.3 551 9.93 257 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 7 ft head ht U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, cir low -e innr, 1/2" w 26 0.320 0 21.3 562 28.6 753 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 cell ins, 5/8" gypsum board int 156 0.020 50.0 1.33 208 1.02 159 fnsh Floors (none) a' City cf T Bold/italic values have been manually overridden Whew - wrightsoft• Rig ht -Su ite® 2017.Ju1-28 15:06:32 U niversal 2017 17.0.23 RSU18166 e 17agg C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W P �� P Mmd,maNkl�^hfti°&l°"°LLC Component Constructions MBATH Hardcastle Mechanical Design LLC 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com Job: Date: Jul 26, 2017 By: David Hardcastle Plan: 17-029 Project Information For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft'-°F ft'-°F/Btuh Btuh/W Btuh Btuh/ft2 Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 51 0.068 19.0 4.54 233 1.26 65 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n 12 0.320 0 21.3 248 9.93 115 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 20 0.020 50.0 1.33 27 1.02 20 fnsh Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft' Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 18 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Hade.,XWN*Ihan,wt0"gnLK Component Constructions Job: Date: Jul 26, 2017 MCLOSET By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Dailyrange (°F) - Wet bulb (OF) - Wind speed (mph) 15.0 Construction descriptions or Area U -value W BtuhM2-°F Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n fnsh, 2"x6" wood frm, 16" o.c. stud w all Partitions (none) 81 0.068 29 0.068 110 0.068 Windows U- 2015: 2 glazing, clr outr, argon gas, vni frm mat, clr low -e innr, 1/2" w 7 0.320 gap, 1/4" thk; 50% blinds 45', medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 48 0.020 fnsh Floors (none) Heating Indoor: 70 Indoor temperature (°F) 67 Design TD (°F) 40 Relative humidity (%) Cooling Moisture difference (gr/Ib) 95 Infiltration: 27 ( H ) Method 60 Construction quality 7.5 Fireplaces Construction descriptions or Area U -value W BtuhM2-°F Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n fnsh, 2"x6" wood frm, 16" o.c. stud w all Partitions (none) 81 0.068 29 0.068 110 0.068 Windows U- 2015: 2 glazing, clr outr, argon gas, vni frm mat, clr low -e innr, 1/2" w 7 0.320 gap, 1/4" thk; 50% blinds 45', medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 48 0.020 fnsh Floors (none) Heating Cooling 70 75 67 20 40 50 46.8 -39.8 Simplified Semi -tight 1 (Average) Insul R Htg HTM Loss Clg HTM Gain W-°F/Btuh Btuh/ff Btuh Btuh/ftp Btuh 19.0 4.54 367 1.26 102 19.0 4.54 133 1.26 37 19.0 4.54 500 1.26 139 0 21.3 143 27.8 187 50.0 1.33 64 1.02 49 City of Bold/italic values have been manually overridden (Wheat R i,inp 2017•Jul-28 15,.06:32 �on � wrightsoft` Right -Suite® Universal 2017 17.0.23 RSU1 8166 Page 19j�O AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W wrecscw W—funitW o«+gn►LC Component Constructions Job: Date: Jul 26, 2017 ST By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc0020gmail.com Projectformation For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Dailyrange (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft' BtuhAF-°F ft'-°F/Btuh Btuh/t? Btuh BtuhR12 Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 WrightSO t- Right -Su ite@Universal 2017 17.0.23 RSU 18166 Page 20 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W wrd""10 84Cf s"Wit11 Job: Component Constructions Date: Jul 26, 2017 BATH2 By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Daily range (°F) - Wet bulb (OF) - Wind speed (mph) 15.0 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft'-°F W-°FBtuh Btuh/ft= Btuh Btuh/ftp Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int a 38 0.068 19.0 4.54 174 1.26 48 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e 7 0.320 0 21.3 143 27.8 187 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden �^- w wrightsoft' Right -Suite@ Universal 2017 17.0.23 RSU18166 M AC:\Users\Diana\Desktop\3330 Chase St.rup Calc = VIA Building Front faces: W City of 2017 -Jul -2815:06:32 r; Page 21 , Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 67 20 Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 27 ( H ) Method Simplified 60 Construction quality Semi -tight 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft'-°F W-°FBtuh Btuh/ft= Btuh Btuh/ftp Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int a 38 0.068 19.0 4.54 174 1.26 48 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e 7 0.320 0 21.3 143 27.8 187 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2.6 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden �^- w wrightsoft' Right -Suite@ Universal 2017 17.0.23 RSU18166 M AC:\Users\Diana\Desktop\3330 Chase St.rup Calc = VIA Building Front faces: W City of 2017 -Jul -2815:06:32 r; Page 21 , w,d:"awen.ntauo"n".0 Component Constructions Job: Date: Jul 26, 2017 LAUNDRY By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc00209mail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Dailyrange (°F) - Wet bu Ib (OF) - Wind speed (mph) 15.0 Construction descriptions Indoor: Heating Cooling Insul R Indoor temperature (°F) 70 75 Design TD (°F) 67 20 ft2-°F/Btuh Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 27 ( H ) Method Simplified 0.068 60 Construction quality Semi -tight 76 7.5 Fireplaces 1 (Average) 0.068 Construction descriptions Or Area U -value Insul R Htg HTM Loss Cig HTM Gain ft2 BtuhAt2-°F ft2-°F/Btuh BtuhN Btuh BtuhN Btuh Walls 12E-Osw: Firm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int s 60 0.068 19.0 4.54 274 1.26 76 fnsh, 2"x6" wood frm, 16" o.c. stud w 63 0.068 19.0 4.54 286 1.26 79 all 123 0.068 19.0 4.54 560 1.26 155 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" s 12 0.320 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 1613-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" 56 0.020 gypsum board int fnsh Floors (none) Bold/italic values have been manually overridden A;. + wrightsofi` Right-Suite(g) U niv ersal 2017 17.0.23 RSU18166 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W 0 21.3 248 11.9 138 50.0 1.33 75 1.02 57 2017 -Jul -28 15:06:32 Page 22 W+dtbode Yadfsaitw D"n LLC Component Constructions MECH Hardcastle Mechanical Design LLC 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc0020gmail.com Job: Date: Jul 26, 2017 By: David Hardcastle Plan: 17-029 Project • • For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-'F 82-'F/Btuh Btuh/112 Btuh Btuh/ft2 Btuh Walls 12E-Osw: Firm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int s 27 0.068 19.0 4.54 122 1.26 34 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 21 0.020 fnsh Floors (none) Bold/italic values have been manually overridden „ wrightSOft' Right -Suite@ U niversal 2017 17.0.23 RSU18166 ,CA C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MA Building Front faces: W 50.0 1.33 28 1.02 21 ity of 2017 -Jul -28 15:06:32, 1 Page 23 H�&*t°'"""iwe1Dii9nLLC Component Constructions Job: Date: Jul 26, 2017 ST2 By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmall.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuildersCaol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Daily range (°F) - Wet bu Ib (° F) - Wind speed (mph) 15.0 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/tt2-°F R2-'F/Btuh BtuhM2 Btuh BtuhM2 Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 54 0.020 50.0 1.33 72 1.02 55 fnsh Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft' Right -Suite@ U niversal 2017 17.0.23 RSU18166 Page 24 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 67 20 Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 27 ( H ) Method Simplified 60 Construction quality Semi -tight 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/tt2-°F R2-'F/Btuh BtuhM2 Btuh BtuhM2 Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 54 0.020 50.0 1.33 72 1.02 55 fnsh Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft' Right -Suite@ U niversal 2017 17.0.23 RSU18166 Page 24 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W w°°°•°�*• "ftcwD"9ftLLC Component Constructions Job: U -value ROOM2 Date: Jul 26, 2017 Loss Clg HTM Gain By: David Hardcastle ft� Hardcastle Mechanical Design LLC Plan: 17-029 Btuh/ft2 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com Btuh Walls Project• • For: Residential New Construction, Mann Builders 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 3330 Chase St., Wheat Ridge, CO 80212 0.068 19.0 4.54 Email: mannbuilders@aol.com 125 fnsh, 2"x6" wood frm, 16" o.c. stud a Design Conditions 0.068 19.0 Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Dailyrange (°F) - 27 ( H ) Method Simplified Wetbulb(°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft� Btuh/ft2-°F ft2-°F/Btuh Btuh/ft2 Btuh Btuh/ftp Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 99 0.068 19.0 4.54 449 1.26 125 fnsh, 2"x6" wood frm, 16" o.c. stud a 148 0.068 19.0 4.54 670 1.26 186 all 247 0.068 19.0 4.54 1119 1.26 310 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e 23 0.320 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 66 0.020 fnsh Floors (none) Bold/italic values have been manually overridden 0 21.3 496 28.5 662 50.0 1.33 88 1.02 67 2017 -Jul -28 15:06:32 twrightsofgtn Right-Suite®Universal 2017 17.0.23 RSU1 8166 Page 25 Z51 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Mtd-*de'-4�towlD"nLLC Component Constructions HALL Hardcastle Mechanical Design LLC 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmall.com Job: Date: Jul 26, 2017 By: David Hardcastle Plan: 17-029 Project• • For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Dailyrange (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/W-T ft2-°F/Btuh Btuh/W Btuh BtuhN Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" 16 0.020 gypsum board int fnsh Floors (none) Bold/italic values have been manually overridden 50.0 1.33 21 1.02 16 ti2017-Jul-28 15:06:32 wrightsoft` Right -Suite@ U niversal 2017 17.0.23 RSU18166 Page 26 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W MaWt*rM*1 hhnkst 0"i9n LLC Component Constructions Job: Date: Jul 26, 2017 POWDER By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40'N Outdoor: Heating Dry bulb (°F) 3 Daily range (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain W Btuh/W-°F ftp-°F/Btuh Btuh/W Btuh Btuh/W Btuh Walls 12F-Osw: Firm wall, stucco ext, 3/8" wood shth, r-21 cav ins, 1/2" n 81 0.065 21.0 4.34 351 1.07 86 gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 36 0.020 fnsh Floors (none) Bold/italic values have been manually overridden 50.0 1.33 48 1.02 37 City of ... , :rine 2017 -Jul -28 15:06:32 wrightsoft• Right -Suite® Universal 2017 17.0.23 RSU18166 Page 27'c ^W W++ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W y� -.11" Indoor: Heating Cooling Indoor temperature (OF) 70 75 Design TD (°F) 67 20 Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 27 ( H ) Method Simplified 60 Construction quality Semi -tight 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss CIg HTM Gain W Btuh/W-°F ftp-°F/Btuh Btuh/W Btuh Btuh/W Btuh Walls 12F-Osw: Firm wall, stucco ext, 3/8" wood shth, r-21 cav ins, 1/2" n 81 0.065 21.0 4.34 351 1.07 86 gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows (none) Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 36 0.020 fnsh Floors (none) Bold/italic values have been manually overridden 50.0 1.33 48 1.02 37 City of ... , :rine 2017 -Jul -28 15:06:32 wrightsoft• Right -Suite® Universal 2017 17.0.23 RSU18166 Page 27'c ^W W++ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W y� -.11" N.r4 wWU—h*nkol0"ignLLC Component Constructions Job: Date: Jul 26, 2017 FLEXSPACE By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmall.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Dailyrange (°F) - Wet bu Ib (° F) - Wind speed (mph) 15.0 Heating Indoor: 70 Indoor temperature (°F) 67 Design TD (°F) 40 Relative humidity (%) Cooling Moisture difference (gr/Ib) 95 Infiltration: 27 ( H ) Method 60 Construction quality 7.5 Fireplaces Heating Cooling 70 75 67 20 40 50 46.8 -39.8 Simplified Btuh/ft2-°F Semi -tight Btuh/W 1 (Average) BtuhM2 Construction descriptions Or Area Ll -value Insul R Htg HTM Loss Clg HTM Gain ft= Btuh/ft2-°F ftp-°F/Btuh Btuh/W Btuh BtuhM2 Btuh Walls 12F-Osw: Frm wall, stucco ext, 3/8" wood shth, r-21 cav ins, 1/2" n 63 0.065 21.0 4.34 273 1.07 67 gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud a 151 0.065 21.0 4.34 655 1.07 161 s 108 0.065 21.0 4.34 468 1.07 115 all 322 0.065 21.0 4.34 1396 1.07 343 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" a 38 0.320 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.9 ft window ht, 1 ft sep.); 7 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 232 0.020 fnsh Floors (none) Bold/italic values have been manually overridden 0 21.3 811 28.5 1084 50.0 1.33 309 1.02 237 2017 -Jul -28 15:06:32 �^C wrightsof� Right -Suite@ U niversal 2017 17.0.23 RSU1 8166 Page 28 Z& C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Rudass910 D"i9ft LLC Component Constructions Job: Date: Jul 26, 2017 SKYLOUNGE By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com kiLlect intormation For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Construction descriptions Design Conditions U -value Insul R Location: Loss Clg HTM Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Btuh/ftp-°F Indoor temperature (°F) 70 75 Elevation: 5285 ft Btuh Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: 1.07 134 Dailyrange (°F) - 27 ( H ) Method Simplified 21.0 Wetbulb(°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) 4.34 Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain ft� Btuh/ftp-°F ft2-°F/Btuh BtuhM2 Btuh Btuh/ft= Btuh Walls 12F-Osw: Frm wall, stucco ext, 3/8" wood shth, r-21 cav ins, 1/2" n 126 0.065 21.0 4.34 546 1.07 134 gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud s 162 0.065 21.0 4.34 702 1.07 173 w 115 0.065 21.0 4.34 497 1.07 122 all 403 0.065 21.0 4.34 1746 1.07 429 Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w 26 0.320 0 21.3 562 28.6 753 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht 10D -v: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" w 48 0.490 0 32.7 1569 22.3 1072 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 It overhang (8 ft window ht, 1 ft sep.); 6.67 ft head ht Doors (none) Ceilings 16B-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int 308 0.020 50.0 1.33 411 1.02 315 fnsh Floors (none) Bold/italic values have been manually overridden wrightsoft' Right-Suite®Universal 201717.0.23 RSU18166 2017 -Jul -28 15:06:32Page 29 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W !i'McptN Neehknkalt3..iyn 41CCompr�onent Constructions Component Job: Conditions Date: Jul 26, 2017 DINING By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com •jec"nTormation For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft'-°F ft'-°F/Btuh BtuhN Btuh Btuh/ft2 Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 50 0.068 19.0 4.54 229 1.26 63 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n 40 0.320 0 21.3 844 9.93 393 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 it overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft Rig ht -Su ite@ U niversal 2017 17.0.23 RSU18166 Pae 30 ^C6^ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Design Conditions Location: Indoor: Heating Cooling Denver Stapleton Int'I AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5285 ft Design TD (°F) 67 20 Latitude: 40°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.8 -39.8 Dry bulb (°F) 3 95 Infiltration: Daily range (°F) - 27 ( H ) Method Simplified Wet bulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft'-°F ft'-°F/Btuh BtuhN Btuh Btuh/ft2 Btuh Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int n 50 0.068 19.0 4.54 229 1.26 63 fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" n 40 0.320 0 21.3 844 9.93 393 gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 it overhang (5.1 ft window ht, 1 ft sep.); 8 ft head ht Doors (none) Ceilings (none) Floors (none) Bold/italic values have been manually overridden 2017 -Jul -28 15:06:32 wrightSoft Rig ht -Su ite@ U niversal 2017 17.0.23 RSU18166 Pae 30 ^C6^ C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W w.ner.r,.nu►ft�..yn4Gc Component Constructions Job: Date: Jul 26, 2017 ROOMS By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Location: Denver Stapleton Int'I AP, CO, US Elevation: 5285 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 3 Daily range (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 Construction descriptions Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft2-°F W-°F/Btuh Btuh/ft2 Btuh Btuh/W Btuh e S all Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht s all Doors (none) Ceilings 1613-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh Floors (none) 67 Indoor: Heating Cooling 0.068 Indoor temperature (°F) 70 75 19.0 Design TD (°F) 67 20 23 Relative humidity (%) 40 50 Cooling Moisture difference (gr/Ib) 46.8 -39.8 95 Infiltration: 20.2 938 27 ( H ) Method Simplified 60 Construction quality Semi -tight 7.5 Fireplaces 1 (Average) Construction descriptions Walls 12E-Osw: Frm wall, stucco ext, r-19 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Or Area U -value Insul R Htg HTM Loss Clg HTM Gain W Btuh/ft2-°F W-°F/Btuh Btuh/ft2 Btuh Btuh/W Btuh e S all Windows U- 2015: 2 glazing, clr outr, argon gas, vnl frm mat, clr low -e innr, 1/2" e gap, 1/4" thk; 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (4.5 ft window ht, 1 ft sep.); 7 ft head ht s all Doors (none) Ceilings 1613-50md: Attic ceiling, mtl roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh Floors (none) 67 0.068 19.0 121 0.068 19.0 188 0.068 19.0 23 0.320 0 23 0.320 0 47 0.320 0 112 0.020 50.0 4.54 303 1.26 84 4.54 548 1.26 152 4.54 850 1.26 236 21.3 496 28.5 662 21.3 496 11.9 276 21.3 992 20.2 938 1.33 149 1.02 114 Bold/italic values have been manually overridden 4 wrightSOft• Right -Suite® Universal 2017 17.0.23 RSU1 8166 2017-Jul-2815:08[32Page 31 AMC:\Users\Diana\Desktop\3330 Chase St.rup Calc =MJ8 Building Front faces: W \BuZ C�iVisott ACCKs Rf Gorblo'11i ikrisCds dkn� Jefferson County Header Information Contractor: Hardcastle Mechanical Design LLC REQUIRED ATTACHMENTS Manual J1 Form (and supporting worksheets): Mechanical license: or MJ1AE Form' (and supporting worksheets): OEM performance data (heating, cooling, blower) Building plan #: 17-029 Manual D Friction Rate Worksheet: Duct distribution sketch: Home address (Street or Lot#, Block, Subdivision): 3330 Chase St., AH1 Form RPER 1 15 Mar 09 ATTACHED Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Design Conditions 767 cfm Building Construction Information ft Winter Design Conditions 0.60 in H2O Building ft Total device pressure losses: Outdoor temperature: 3 IF Orientation: Building Front faces West 0.28 Indoor temperature: 70 of North, East, West, South, Northeast, Northwest, Southeast, Southwest Total heat loss: 24460 Btuh Number of bedrooms: 0 Conditioned floor area: 2446 ft2 Summer Design Conditions Number of occupants: 1 Outdoor temperature: 95 IF Indoor temperature: 75 OF Windows Roo+ Grains difference: -40 gr/Ib @50% RH Eave overhang depth: 1,5 ft Sensible heat gain: 13953 Btuh Internal shade: blinds E$�G Latent heat gain: 0 Btuh Blinds, drapes, etc.wi ndow Total heat gain: 13953 Btuh Number of skylights: 0 EQUIPMENTHVAC • 41 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Hea Boiler, Gas furnace ETjipcment type: it onditio r, Heat etc. Split AC Heating cfm: 552 umace, pump, etc. pump, Cooling cfm: 767 Model: Carrier Model: Carrier Static pressure: 0.60 in H2O 59TP5A040E17--12 24ACB324ABN32 Fan's rated external static pressure for design airflow Heating output capacity:5�00� Btuh Total cooling capacity: 0 Btuh Heat pumps - capacity at nter design o r co dations Sensible cooling capacity: 0 Btuh Aux. heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh Design airflow: 767 cfm Longest supply duct: 194 ft Equipment design ESP: 0.60 in H2O Longest return duct: 148 ft Total device pressure losses: -0.3 in H2O Total effective length (TEL): 343 ft Available static pressure (ASP): 0.28 in H2O Friction rate:0.�2 in/100ft Friction R ate = ASP-,(TEL SP , (TEL x Contractor's printed name: Contractor's signature: 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist + wrightSoft• Right -Suite@ Universal 2017 17.0.23 RSU18166 Duct Materials Used Trunk duct: Sheet metal Branch duct: Round flex vinyl, Sheet metal Date: A AO a aMama a+ mm Jefferson County Header Information Contractor: Hardcastle Mechanical Design LLC REQUIRED ATTACHMENTS Manual J1 Form (and supporting worksheets): Mechanical license: or MJ1AE Form' (and supporting worksheets): OEM performance data (heating, cooling, blower) Building plan #: 17-029 Manual D Friction Rate Worksheet: Duct distribution sketch: Home address (Street or Lot#, Block, Subdivision): 3330 Chase St., AH2 Form PIPER 1 15 Mar 09 ATTACHED Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 3 OF Orientation: Building Front faces West Indoor temperature: 70 of North, East, West, South, Northeast, Northwest, Southeast, Southwest Total heat loss: 25435 Btuh Number of bedrooms: 0 Conditioned floor area: 1819 ft2 Summer Design Conditions Number of occupants: 4 Outdoor temperature: 95 IF Indoor temperature: 75 IF Windows Boor Grains difference: -40 gr/Ib @50% RH Eave overhang depth: 1,5 ft Sensible heat gain: 14271 Btuh Internal shade: blinds Latent heat gain: 0 Btuh Blinds, drapes, etc. oeptN YY rduw Total heat gain: 14271 Btuh Number of skylights: 0 4LWAC EQUIPMENT• 41 Heating_ Equipmont_Data Cooling _Equipment Data BLoweLD-ata Equipment type: Hea Boiler, Gas furnace Equipment tape: Split AC Heating cfm: 861 u nace, pump, etc. it conditioner, Heat pump, etc. Cooling cfm: 580 Model: Carrier Model: Carrier Static pressure: 0.60 in H2O 59SP5A040E17--12 24ACB318ABN32 Fan's rated external static pressure for design Heatinq� output capaci Heat �90p0 Btuh Total cooling capacity: airflow 0 Btuh p mps - capacity at nter design out oor onditions Sensible cooling capacity: 0 Btuh Aux. heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh DISTRIBUTIONHVAC DUCT .1 Design airflow: 861 cfm Longest supply duct: 235 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 216 ft Trunk duct: Sheet metal Total device pressure losses: -0.1 in H2O Total effective length (TEL): 451 ft Available static pressure (ASP): 0.36 in H2O Friction rate: O,r)RO in/100ft Branch duct: Sheet metal Friction Rate= ASP : (TEL x r�oofl Contractor's printed name: Contractor's signature: Date: 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist * wrightsoft' Rig ht -Su ite@ U niv ersal 2017 17.0.23 RSU18166 Nut"efM 06.i9°uC Static Pressure and Friction Rate Job: Date: Jul 26, 2017 AH 1 By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmaii.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Return 6M=20, 6A6=75, 5A=40: TotalEL=135 2017 -Jul -28 15:06:34 wrightsoft' Rig ht -Su ite@ U niversal 2017 17.0.23 RSU18166 Page 1 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Heating Cooling (in H2O) (in H2O) External static pressure 0.60 0.60 Pressure losses Coil 0.18 0.1E Heat exchanger 0 C Supply diffusers 0.03 0.01 Return grilles 0.03 0.01 Filter 0.08 0.0E Humidifier 0 C Balancing damper 0 C Other device 0 C Available static pressure 0.28 0.28 Total• Supply Return (ft) (ft) Measured length of run -out 12 4 Measured length of trunk 12 9 Equivalent length of fittings 170 135 Total length 194 148 Total effective length 343 FrictionRate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.082 OK 0.082 OK Return Ducts 0.082 OK 0.082 OK Fitting Equivalent LengthDetails Supply 4G=80, 21<11=601121-1=10, 1 P=20: TotalEL=170 Return 6M=20, 6A6=75, 5A=40: TotalEL=135 2017 -Jul -28 15:06:34 wrightsoft' Rig ht -Su ite@ U niversal 2017 17.0.23 RSU18166 Page 1 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W $Urge EleW"t.^it„u.,iynii` Static Pressure and Friction Rate Job: Date: Jul 26, 2017 AH2 By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Co 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com ti, + wrightsoft' Right -Suite@ Universal 2017 17.0.23 RSU18166 )IM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W City 01 2017 -Jul -28 15:06:34 Bulldiw, Page 4 Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.60 Pressure losses Coil 0 0.18 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.08 0.08 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.36 0.28 Total• Supply Return (ft) (ft) Measured length of run -out 12 6 Measured length of trunk 28 20 Equivalent length of fittings 195 190 Total length 235 216 Total effective length 451 FrictionRate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.080 OK 0.062 OK Return Ducts 0.080 OK 0.062 OK Fitting Equivalent LengthDetails Supply 4G=80, 8AF=15, 2K0=50, 121_1=10, 9L=20, 1 P=20: TotalEL=195 Return 6M=201 6A6=75, 12D1=20, 10B=10, 6AB=25, 5A=40: TotalEL=190 ti, + wrightsoft' Right -Suite@ Universal 2017 17.0.23 RSU18166 )IM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W City 01 2017 -Jul -28 15:06:34 Bulldiw, Page 4 'u�'°'��slD"4nLLC Duct System Summary AM Hardcastle Mechanical Design LLC 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com Job: Date: Jul 26, 2017 By: David Hardcastle Plan: 17-029 Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.32 in H2O 0.32 in H2O Available static pressure 0.28 in H2O 0.28 in H2O Supply / return available pressure 0.159 / 0.121 in H2O 0.159 / 0.121 in H2O Lowest friction rate 0.082 in/100ft 0.082 in/100ft Actual air flow 552 cfm 767 cfm Total effective length (TEL) 343 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CRAWL h 2295 58 5 0.086 4.0 Ox 0 VIFx 15.0 170.0 st2 CRAWL -A h 2295 58 5 0.092 4.0 Ox 0 VIFx 12.5 160.0 st1 DINING h 1387 35 27 0.088 4.0 Oxo VIFx 16.3 165.0 st1 FOYER h 1727 44 33 0.085 4.0 Ox 0 VIFx 17.0 170.0 st1 KITCHEN c 1539 26 90 0.082 5.0 Ox 0 VIFx 24.2 170.0 st2A LIVING c 1548 42 90 0.088 5.0 Ox 0 VIFx 19.4 160.0 st2A LIVING -A c 1548 42 90 0.082 5.0 Ox 0 VIFx 18.0 175.0 st2 LIVING -B c 1548 42 90 0.090 5.0 Ox 0 VIFx 26.8 150.0 st2 LIVING -C c 1548 42 90 0 0 Ox 0 VIFx 0 0 LIVING -D c 1548 42 90 0.099 5.0 Oxo VIFx 10.7 150.0 st1 MUD h 1377 35 21 0.087 4.0 Oxo VIFx 22.9 160.0 st2 PWDR h 838 21 19 0.086 4.0 Ox 0 VIFx 19.2 165.0 st2 STUDY c 1006 33 59 0.106 4.0 Ox 0 ShMt 20.1 130.0 st1 A STUDY -A c 1006 33 59 0.082 4.0 Ox 0 VIFx 23.7 170.0 st1 A Bold/italic values have been manually overridden 2017 -Jul -28 15:06:34 wrightsOft' Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 1 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 265 405 0.082 728 10.2 8 x 10 ShtMetl sti Peak AVF 245 272 0.082 817 8.8 8 x 6 ShtMetl st1A Peak AVF 66 117 0.082 859 5.0 0 x 0 ShtMetl st1 st2A Peak AVF 68 180 0.082 915 6.0 0 x 0 ShtMetl st2 Bold/italic values have been manually overridden 2017 -Jul -28 15:06:34 wrightsOft' Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 1 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Name Grille Size (in) Htg (Cf M) Clg (Cf M) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb3 24x 15 552 767 148.5 0.082 549 16.0 Ox 0 VIFx rt1 Return Trunk Detail Table Name Trunk Type Htg (Cf M) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 Peak AVF 552 767 0.082 690 13.0 16 x 10 ShtMetl wrightSOW Right -Suite® Universal 2017 17.0.23 RSU18166 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W 2017 -Jul -28 1 �;t;t�ditag Div %wkw$aN*e"neuD"iSnLLC Duct System Summa Job: y Date: Jul 26, 2017 AH2 By: David Hardcastle Hardcastle Mechanical Design LLC Plan: 17-029 446 Elm ave, Brighton, Cc 80601 Phone: 720 404 7425 Email: davidhc002@gmail.com For: Residential New Construction, Mann Builders 3330 Chase St., Wheat Ridge, CO 80212 Email: mannbuilders@aol.com External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.14 in H2O 0.36 in H2O 0.188 / 0.172 in H2O 0.080 in/100ft 861 cfm 451 ft Cooling 0.60 in H2O 0.32 in H2O 0.28 in H2O 0.146 / 0.134 in H2O 0.062 in/100ft 580 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH2 h 420 16 11 0.112 4.0 Ox 0 ShMt 17.0 150.0 st7 FLEXSPACE h 895 65 39 0 0 Ox 0 ShMt 0 0 396 FLEXSPACE-A h 895 65 39 0 0 Ox 0 ShMt 0 0 144 LAUNDRY h 1292 50 17 0.089 4.0 Ox 0 ShMt 25.0 185.0 st8 MASTER h 1222 54 53 0.062 4.0 Ox 0 ShMt 40.0 195.0 st8A MASTER -A h 1222 54 53 0.063 4.0 Ox 0 ShMt 42.0 190.0 st8A MBATH h 652 25 8 0.104 4.0 Ox 0 ShMt 30.0 150.0 st8 MCLOSET h 970 38 20 0.082 4.0 Ox 0 ShMt 30.0 200.0 st8 POWDER h 129 23 6 0 0 Ox 0 ShMt 0 0 ROOM2 h 2310 90 76 0.085 5.0 Ox 0 ShMt 36.0 185.0 st7 ROOM3 h 1313 51 39 0.089 4.0 Ox 0 ShMt 26.0 185.0 st7 ROOMS -A h 1313 51 39 0.092 4.0 Ox 0 ShMt 20.0 185.0 st7 SKYLOUNGE h 2706 105 71 0.086 5.0 Ox 0 ShMt 32.0 185.0 st8 SKYLOUNGE-A h 1634 105 71 0 0 Ox 0 ShMt 0 0 STAIR2 h 1790 69 37 0.099 4.0 Ox 0 ShMt 30.0 160.0 st8B Supply Trunk Detail Table Bold/italic values have been manually overridden 2017 -Jul -28 15:06:34 wrightSOW Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 3 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st7 Peak AVF 208 165 0.085 778 7.0 0 x 0 ShtMetl st3 st8 Peak AVF 396 260 0.080 713 10.2 8 x 10 ShtMetl st3 st8A Peak AVF 178 144 0.080 906 6.0 0 x 0 ShtMetl st8 st8B Peak AVF 69 37 0.099 796 4.0 0 x 0 ShtMetl st8A st3 Peak AVF 604 425 0.080 776 11.9 8 x 14 ShtMetl Bold/italic values have been manually overridden 2017 -Jul -28 15:06:34 wrightSOW Right -Suite@ Universal 2017 17.0.23 RSU18166 Page 3 C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W Bold/italic values have been manually overridden !;_�_ + wrightSO Right -Suite@ Universal 2017 17.0.23 RSU18166 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W 0— c;�y 01 2017 -Jul -28 15:06:34 Page 4 Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Type Name Size (in) (Cf m) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 10x7 157 74 121.0 0.142 588 7.0 Ox 0 189 ShMt rt3 rb5 10x5 106 87 136.0 0.127 540 6.0 Ox 0 623 ShMt rt4 rb1 10x 5 102 78 205.0 0.084 519 6.0 Ox 0 0 x 0 ShMt rt4A rb6 10x6 134 115 216.0 0.080 501 7.0 Ox 0 ShMt rt3A rb4 20x 8 362 226 0 0 0 0 Ox 0 ShMt Bold/italic values have been manually overridden !;_�_ + wrightSO Right -Suite@ Universal 2017 17.0.23 RSU18166 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W 0— c;�y 01 2017 -Jul -28 15:06:34 Page 4 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cf m) (cfm) FR (fpm) (in) (in) Material Trunk r13A Peak AVF 134 115 0.080 501 7.0 0 x 0 ShtMetl rt3 rt3 Peak AVF 291 189 0.080 655 9.1 8 x 8 ShtMetl rt2 rt4 Peak AVF 208 165 0.084 623 7.9 8 x 6 ShtMetl rt2 rt4A Peak AVF 102 78 0.084 519 6.0 0 x 0 ShtMetl rt4 rt2 Peak AVF 499 354 0.080 641 11.1 8 x 14 ShtMetl Bold/italic values have been manually overridden !;_�_ + wrightSO Right -Suite@ Universal 2017 17.0.23 RSU18166 AM C:\Users\Diana\Desktop\3330 Chase St.rup Calc = MJ8 Building Front faces: W 0— c;�y 01 2017 -Jul -28 15:06:34 Page 4 Crawl Space Job #: Performed by David Hardcastle for: Residential New Construction 3330 Chase St. Wheat Ridge, CO 80212 mannbuilders@aol.com Hardcastle Mechanical Design LLC 446 Elm ave Brighton, Co 80601 Phone: 720 404 7425 davidhc002@gmail.com Scale: 1 : 87 Page 1 I RightSuite@ Universal 2017 17.0.23 RSU18166 2017 -Jul -28 15:06:57 \Diana\Desktop\3330 Chase St.rup _ 93 MAIN Job #: Performed by David Hardcastle for: Residential New Construction 3330 Chase St. Wheat Ridge, CO 80212 mannbuilders@aol.com Hardcastle Mechanical Design LLC 446 Elm ave Brighton, Co 80601 Phone: 720 404 7425 davidhc002@gmail.com Cfm Cfm Scale: 1 : 87 Page 2 Ri ghtSuite®Univeisal 2017 17.0.23 RSU18166 2017 -Jul -28 15:06:57 \Diana\Desktop\3330 Chase St.rup SECOND Job #: Performed by David Hardcastle for: Residential New Construction 3330 Chase St. Wheat Ridge, CO 80212 mannbuilders@aol.com Hardcastle Mechanical Design LLC 446 Elm ave Brighton, Co 80601 Phone: 720 404 7425 davidhc002@gmail.com Scale: 1 : 87 Page 3 I RightSuite® Universal 2017 17.0.23 RSU18166 2017 -Jul -28 15:06:57 \Diana\Desktop\3330 Chase St.rup 1 THIRD POW D K 105 cfm 23 cf 362 cfm 5 ST' SKYLOUNG FLEXSPAC 105 cfm 5 Job #: Performed by David Hardcastle for: Residential New Construction 3330 Chase St. Wheat Ridge, CO 80212 mannbuilders@aol.com Hardcastle Mechanical Design LLC 446 Elm ave Brighton, Co 80601 Phone: 720 404 7425 davidhc002@gmail.com cfm cfm Scale: 1 : 87 Page 4 RightSuite® Universal 2017 17.0.23 RSU18166 2017 -Jul -28 15:06:57 \Diana\Desktop\3330 Chase St.rup e Generated by REScheck-Web Software Compliance Certificate Project 3330 Chase Street Energy Code: 2015 IECC Location: Wheat Ridge, Colorado Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 270 deg. from North Conditioned Floor Area: 3,100 ft2 Glazing Area 17% Climate Zone: 5 (6158 HDD) Permit Date: Permit Number: 18 Construction Site: Owner/Agent: 3336 Chase Street Laurie Middleton Wheat Ridge, Colorado 80212 Mann Real Estate 0.0 0.059 7165 West 32nd Avenue 86 Wheat Ridge, Colorado 80033 Designer/Contractor: Jeff Van Sambeek Lodestone Design Group 701 Delaware Avenue Suite C Longmont, Colorado 80501 (303)800-8633 sky@lodestonedesign.com Compliance: Passes using UA trade-off Compliance: 1.9% Better Than Code Maximum UA: 529 Your UA: 519 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Roof Deck Ceiling: Flat or Scissor Truss North Wall: Wood Frame, 16in. o.c. Orientation: Left side Window: Vinyl Frame, 2 Pane w/ Low -E Orientation: Left side East Wall: Wood Frame, 16in. o.c. Orientation: Back Window: Vinyl Frame, 2 Pane w/ Low -E Orientation: Back Door: Glass Orientation: Back South Wall: Wood Frame, 16in. o.c. Orientation: Right side Window: Vinyl Frame, 2 Pane w/ Low -E Orientation: Right side West Wall: Wood Frame, 16in. o.c. Orientation: Front Window: Vinyl Frame, 2 Pane w/ Low -E Orientation: Front Door: Glass Orientation: Front Project Title: 3330 Chase Street Data filename: 1,197 49.0 0.0 0.026 31 1,036 20.0 0.0 0.059 53 134 0.300 40 886 20.0 0.0 0.059 37 59 0.300 18 192 0.300 58 1,032 20.0 0.0 0.059 56 86 0.300 26 932 20.0 0.059 44 118 City of ON3W 35 72 1 wheat Rid41301 22 �',',y 06/28/17 Page 1 of10 Floor: All -Wood Joist/Truss Over Uncond. Space 1,197 30.0 0.0 0.033 40 Crawl: Solid Concrete or Masonry 1,197 0.0 13.0 0.063 59 Wall height: 3.3' Depth below grade: 2.7' Insulation depth: 3.3' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Project Title: 3330 Chase Street Re Data filename: Date 01i 0' V� Q 't dafe: 06/28/17 Page 2 of10 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Verified { Field Verified Value Value Contplies2 Comments/Assumptions 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 documentation demonstrate ❑Does Not (PR1]1 energy code compliance for the ❑Not Observable building envelope. Thermal ❑Not Applicable envelope represented on construction documents. 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for ❑Not Observable [PR3]1 lighting and mechanical systems. , Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: City of Wheat Ridge High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1.3 1 Low Impact (Tier 3) Building Divi Project Title: 3330 Chase Street Report date =028/17 Data filename: Page 3 of10 Section plans Verified Eield Verified Value Complies? Comments/Assumptions & Req.I® 402.2.11 Unvented crawl space wall R- R- ❑Complies See the Envelope Assemblies [F0711 insulation R -value. R- R- ❑Does Not table for values. ❑Not Observable ❑Not Applicable 303.2 Unvented crawl space wall ❑Complies Requirement will be met. [F0811 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.11 Unvented crawl space continuous . [Complies Requirement will be met. [F0911 vapor retarder installed over ❑Does Not exposed earth, joints overlapped by 6 in. and sealed, extending at -❑Not Observable least 6 in. up and attached to the ` ❑Not Applicable wall. 402.2.11 Unvented crawl space wall in. in. ❑Complies See the Envelope Assemblies [FO10]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies Exception: Requirement is [FO11]2 to protect exposed exterior ❑Does Not not applicable. insulation and extends a - minimum of 6 in. below grade. ;❑Not Observable _ ❑Not Applicable 403.9 Snow- and ice -melting system ❑Complies Exception: Requirement is [FO12]2 controls installed. ?❑Does Not not applicable. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: city of Wheat Ridge 11 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) °},Rui ding Divisn Project Title: 3330 Chase Street Report date: 06/28/17 Data filename: Page 4 of 10 Section # Framing / Rough-9n Inspection Plans Verified Valeae Field Verified Value Complies? s/Assumptions & Req,1® 402.1.1, Glazing U-factor (area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products '❑Complies Requirement will be met. [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA /WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 400 that do not exceed code []Not Applicable limits. 1t402.4.5 IC-rated recessed lighting fixtures housing/interior ❑Complies Requirement will be met. s[FR16]2 sealed at finish ❑Does Not and labeled to indicate :52.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies Requirement will be met. [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not .[-]Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met. [FR17]2 above 105 9F or chilled fluids ❑Does Not - below 55 9F are insulated to aR- ❑Not Observable 3 ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies Requirement will be met. [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable Hot water pipes are insulated to R- R- ❑Complies Requirement will be met. �403.5.3 [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: City of Wheat Ridge (Tier 1) 1 2 , Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) \ nn Divisor: Project Title: 3330 Chase Street Report ,late; 06/28/17 Data filename: Page 5 of 10 Project Title: 3330 Chase Street Data filename: city of Wheat Ridge (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact (Tier 3) 6iWinn Dwisor, Report date: 06/28/17 Page 6 of 10 se-, rtlon # I Insulation Inspection Plans Verified (Field Qlerifles9 Value Value C®rnplles? Comments/Assumptions & Re .I® 303.1 All installed insulation is labeled ; - ❑Complies , Requirement will be met. [IN13]2 or the installed R -values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R -value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood :F—]Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per [Complies Requirement will be met. 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the ❑Not Observable underside of the subfloor, or floor framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R -value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 [IN3]1 wall insulation on the wall exterior, the exterior insulation Mass Mass []Not Observable requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies Requirement will be met. [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable `❑Not Applicable Additional Comments/Assumptions: City of 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) `"�e�tF)q@ Project Title: 3330 Chase Street Report date: 06/28/17 Data filename: Page 7 of10 Section # Final Inspection Provisions Plans Verified I Value Field Aderifaed I Val ane I Complies? Comments/Assumptions & Re ,1® 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.6 Steel Steel ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not (F12]1 Blown insulation marked every ❑Not Observable 300 ft2. []Not Applicable 402.2.3 Vented attics with air permeable ❑Complies Requirement will be met. (F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. (F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of <=4 cfm/100 cfm/100 ❑Complies Requirement will be met. [F14]1 cfm/100 ft2 across the system or ft2 ftz ❑Does Not <=3 cfm/100 ft2 without air []Not Observable handler @ 25 Pa. For rough-in tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met. [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test: Total ❑Not Observable leakage measured with a pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated [Complies Requirement will be met. [F124]1 by manufacturer at <=2% of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats !❑Complies Requirement will be met. [F[9]2 installed for control of primary '❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed `❑Complies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water [FI11]2 systems have automatic or ;❑Complies ❑Does Not RequiremepxLwdt be met. accessible manual controls.<, ❑Not Observable /001� City of ❑Not Applicable 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: 3330 Chase Street Report date: 06/28/17 Data filename: Page 8 of 10 " Sef tiofe # & Req.ID Final Inspection Provisions j Plans Verified Value Field Vered I Valu® Complies Comments/Assumptions 403.6.1 All mechanical ventilation system ;❑Complies Requirement will be met. [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable []Not Applicable 403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is [F126]2 through one- or two -pipe heating '• ❑Does Not not applicable. systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems .� ❑Complies Requirement will be met. [FI28]2 have a circulation pump. The �❑Does Not system return pipe is a dedicated return pipe or a cold water supply. ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop 'is at set -point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable. 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Exception: Requirement is [F[30]2 have recirculation pumps that ❑Does Not not applicable. pump water from a heated water supply pipe back to the heated +❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies !Exception: Requirement is [FI31]2 tested in accordance with CSA - ❑Does Not not applicable. 855.1. Potable water -side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water - ;side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75% of lamps in permanent []Complies Requirement will be met. [F16]1 fixtures or 75% of permanent "nDoes Not fixtures have high efficacy lamps.` ❑Not Observable Does not apply to low -voltage lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies Exception: Requirement is (FI23]3 no continuous pilot light. ❑Does Not not applicable. ❑Not Observable []Not Applicable 11 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: 3330 Chase Street Report date: 06/28/17 Data filename: Page 9 of 10 I Section plans Verified Field Verified # Final Inspection provisions Value Valu® Complies? Comments/Assumptions ments/Assumptions & Qle .Q� 401.3 'Compliance certificate posted. El Complies Requirement will be met. [FI7lZ '❑Does Not ❑Not Observable _ ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI18j3 mechanical and water heating , ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1I 11 High Impact (Tier 1) Project Title: 3330 Chase Street Data filename: City of Piece Medium Impact (Tier 2) 3 Low Impact (Tier 3) Report date: 06/28/17 Page 10 of10 2015 1ECC Energy A/iEfficiency Certificate Above -Grade Wall 20.00 Below -Grade Wall 13.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Window 0.30 Door 0.30 Heating System: Cooling System:. Water Heater: Name: Date- Comments city of Wheat Ri(-I e ing Divisc: r: ROCKY MOUNTAIN GROUP Job No. 157033 April 4, 2017 Mann Builders LLC 7165 W 32nd Ave Wheat Ridge, CO 80033 Re: Subsurface Soil Investigation 3330 Chase St Formerly known as 3330 Chase St, South Lot Wheat Ridge, Colorado Dear Mann Builders LLC: Rocky Mountain Group (RMG) drilled two test borings at the above -referenced address on March 15, 2017. The layout of the site, existing surface conditions, and the approximate location of our explorations are provided in Figure 1, Aerial Site Map. Our findings, conclusions and recommendations are provided in this report. This report presents geotechnical engineering recommendations for design and construction of residential foundations. The following is excluded from the scope of this report including but not limited to geologic, natural and environmental hazards such as landslides, unstable slopes, seismicity, snow avalanches, water flooding, corrosive soils, erosion, radon, wild fire protection, hazardous waste and natural resources. Site Description and Proposed Construction The site was vacant at the time of our subsurface exploration. Aerial imagery indicates that previous existing structures were on this site. At the time of our subsurface exploration, all previous structures had been removed and the site was roughly graded to be relatively flat across the site Based on conversations with the client, it is our understanding that the existing property will be split into two residential lots. It is our understanding a single family residence with a basement is planned for the proposed construction. Subsurface Materials From the surface in the test borings, man -placed fill soils were encountered to approximately 4 to 7 feet below the existing ground surface. The fill soil generally consisted of lean clay with sand and construction debris and is considered undocumented. The surficial fill soil was underlain by medium hard to very hard clayey sandstone bedrock that extended to the maximum depths explored in the test borings. ( Wheat Ridge South Colorado: Central Colorado: North Colora Colorado Springs, CO Englewood, CO Greeley, CO 719.548.0600 303.688.9475 970.330.1071 Monument: 719.488.2145 Pueblo: 719.544.7750 Woodland Park: 719.687.6077 3330 Chase St South Lot Wheat Ridge, Colorado Groundwater was not encountered in the test borings at the time of drilling or when checked two days subsequent to drilling. Fluctuations in groundwater and subsurface moisture conditions may occur due to variations in rainfall and other factors not readily apparent at this time. Development of the property and adjacent properties may also affect groundwater levels. Additional descriptions and the interpreted distribution (approximate depths) of the subsurface materials are presented in the Test Boring Logs. The soil/rock classifications shown on the logs are based upon the engineer's classification of samples. Lines shown on the logs represent the approximate boundary between subsurface materials, and the actual transition may be gradual and vary across the site. An Explanation of the Test Boring Logs, the Test Boring Logs, and a Summary of Laboratory Test Results are presented in Figures 2 through 4. Soil Classification Data are presented in Figure 5. Swell/Consolidation Test Results are presented in Figure 6. Summary of Findings The most significant geotechnical issue at the site is the presence of the man -place fill soils. We recommend the complete removal of all undocumented fill below foundation bearing components and interior floor slabs. We recommend foundation bearing components bear directly on the sandstone bedrock. Foundation Recommendations A spread footing foundation supported on the on-site bedrock is suitable for the proposed structure. A maximum allowable bearing pressure of 2,500 psf with a minimum dead load requirement of 800 psf may be used for design. A 4 -inch void material should be installed in areas where the minimum dead load cannot be attained. The foundation design should be prepared by a qualified Colorado Registered Professional Engineer using the recommendations presented in this report. This foundation system should be designed to span a minimum of 10 feet under the design loads. The bottoms of exterior foundations should be at least 36 inches below finished grade for frost protection. Open Excavation Observation During construction, foundation excavations should be observed by RMG prior to placing structural fill, forms, or concrete to verify the foundation bearing conditions for each structure. Based on the conditions observed in the foundation excavation, the recommendations made at the time of construction may vary from those contained herein. In the case of differences, the Open Excavation Observation report shall be considered to be the governing document. The recommendations presented herein are intended only as preliminary guidelines to be used for interpreting the subsurface soil conditions exposed in the excavation and determining the final recommendations for foundation construction. Cay of Wheat Ridge ui{ding Uiviso RMG — Rocky Mountain Group 2 Job No. 157033 3330 Chase St South Lot Wheat Ridge, Colorado Interior Floor Slabs Slab performance risk evaluation is an engineering judgement which is used as a predictor of the general magnitude of potential slab heave, and the risk of poor slab performance. The Slab Performance Risk at this site is judged to be `Low' based on the criteria in the following table. Slab Performance Risk Category Representative PercentRepresentative Swell (500 psf Surcharge) Percent Swell (1,000 psf Surcharge) Low 0to<3 0to<2 Moderate 3 to < 5 2 to < 4 High 5 to < 8 4 to < 6 Very High >8 >6 Note: Based on Colorado Association of Geotechnical Engineers, Guidelines for Slab Performance Risk Evaluation and Residential Basement Floor System Recommendations (Denver Metropolitan Area, 1996). The Colorado Association of Geotechnical Engineers (CAGE) recommends structural floors where the slab performance risk is judged to be high or very high. However, the owner must understand that vertical slab movement on the order of two to four inches is considered possible for soils/bedrock of low expansion potential and for structural fill after recommended removal (overexcavation). In some cases, vertical movement may exceed this range. If movement and associated damage to floors and finishes cannot be tolerated, a structural floor system should be used. Floor slabs should be separated from structural components to allow for vertical movement. Control and construction joints should be placed in accordance with the latest guidelines and standards published by the American Concrete Institute (ACI) and applicable local Building Code requirements. Slabs should also be separated from any utility components by isolation joints. Mechanical equipment supported on slabs should be provided with expandable/collapsible sections in order to allow movement of the slab without damage to the equipment or structure. Recommendations for exterior concrete slabs, such as patios, driveways, and sidewalks, are not included in this report. Interior Partitions Interior non-bearing partitions and attached furnishings (e.g., cabinets, shower stalls, etc.) on concrete slabs should be constructed with a void so that they do not transmit floor slab movement to the roof or overlying floor. A void of 3 inches is recommended beneath non- bearing partitions. Doors should be provided with at least a 1 inch gap at floor level. Voids and gaps may require reconstruction over the life of the structure to re-establish the void due to vertical slab movement. Interior non-bearing partitions walls and other attached finishes do not require isolation from the structural floor system. €;iiy of Wheat Ftiijv auiidinq RMG — Rocky Mountain Group 3 Job No. 157033 3330 Chase St South Lot Wheat Ridge, Colorado Lateral Earth Pressure Parameters Foundation walls should be designed to resist lateral earth pressures. For moisture -conditioned, low -expansive, onsite backfill materials, we recommend equivalent fluid pressure of 55 pcf for "Active" conditions and 75 pcf for "At -Rest" conditions be used for design. The above lateral earth pressure applies to level, drained backfill conditions. Equivalent Fluid Pressures for sloping/undrained conditions should be determined on an individual basis. Site Grading The following sections present recommendations for earthwork during construction including site preparation, structural fill, and exterior backfill. Site Preparation Prior to construction the ground surface in proposed structure and improvement areas should be stripped of existing vegetation, debris, topsoil, undocumented fill, soft, loose, or disturbed native soils and other deleterious material. This includes areas below foundation and floor slabs. In areas where clay soils will in placed the exposed subgrade should be kept from desiccating. Site preparation procedures should be performed such that the potential for standing and ponding of water around the site is minimized. During wet weather earthen berms, swales, or other means should be used to route water away from excavations. Water that accumulates in excavations should be promptly pumped out or otherwise removed and these areas should be allowed to dry out before resuming construction. Structural Fill In the event structural fill is needed, areas to receive structural fill should have topsoil, organic material, or debris removed. The upper 6 inches of the exposed surface soils should be scarified and moisture conditioned to facilitate compaction (usually within 2 percent of the optimum moisture content) and compacted to a minimum of 95 percent of the maximum dry density as determined by the Standard Proctor test (ASTM D-698) or to a minimum of 92 percent of the maximum dry density as determined by the Modified Proctor test (ASTM D- 1557) prior to placing structural fill. Scarification may terminate where bedrock is encountered. Structural fill placed on slopes should be benched into the slope. Maximum bench heights should not exceed 4 feet, and bench widths should be wide enough to accommodate compaction equipment. Structural fill shall consist of granular, non -expansive material, and it should be placed in loose lifts not exceeding 8 to 12 inches, moisture conditioned to facilitate compaction (usually within 2 percent of the optimum moisture content) and compacted to a minimum of 92 percent of the maximum dry density as determined by the Modified Proctor -test t,STM D-1557. The materials should be compacted by mechanical means. Wheat Ridge wilding D RMG — Rocky Mountain Group 4 Job No. 157033 3330 Chase St South Lot Wheat Ridge, Colorado Earthwork operations should be observed and compaction of structural fill materials should be tested by the project's geotechnical consultant. It is the responsibility of the builder or contractor to schedule with this office to conduct compaction tests, retrieve or accept delivery of a fill sample, or certify the fill material. Exterior Backfill Backfill should be placed in loose lifts not exceeding 8 to 12 inches, moisture conditioned to facilitate compaction (usually within 2 percent of the optimum moisture content) and compacted to 90 percent of the maximum dry density as determined by the Standard Proctor test, ASTM D-698 on exterior sides of walls in landscaped areas. In areas where backfill supports pavement and concrete flatwork, the materials should be compacted to 95 percent of the maximum dry density. Fill placed on slopes should be benched into the slope. Maximum bench heights should not exceed 4 feet, and bench widths should be wide enough to accommodate compaction equipment. The appropriate government/utility specifications should be used for fill placed in utility trenches. If material is imported for backfill, the material should be approved by the Geotechnical Engineer prior to hauling it to the site. The backfill should not be placed on frozen subgrade or allowed to freeze during moisture conditioning and placement. Backfill should be compacted by mechanical means, and foundation walls should be braced during backfilling and compaction. Surface Grading and Drainage Drainage is an important key to the successful performance of shallow foundations. The ground surface should be sloped away from structures with a minimum gradient of 10 percent for the first 10 feet. This is equivalent to 12 inches of fall across this 10 -foot zone. If a 10 -foot zone is not possible on the upslope side of the structure, then a well-defined Swale should be created a minimum 5 feet from the foundation and sloped parallel with the wall with a minimum slope of 2 percent to intercept the surface water and transport it around and away from the structure. Roof drains should extend across backfill zones and landscaped areas to a region that is graded to direct flow away from the structure. It is imperative that homeowners maintain the surface grading and drainage recommended in this report to help prevent water from being directed toward and/or ponding near the foundations. Failure to maintain positive surface drainage away from the structure may result in localized differential vertical movement of foundations and slabs. Landscaping should be selected to reduce irrigation requirements. Plants used close to foundation walls should be limited to those with low moisture requirements; and irrigated grass should not be located within 5 feet of the foundation. To help control weed growth, geottiles Wheat Ridge Diviso RMG — Rocky Mountain Group 5 Job No. 157033 3330 Chase St South Lot Wheat Ridge, Colorado should be used below landscaped areas adjacent to foundations. Impervious plastic membranes are not recommended. Irrigation devices should not be placed within 5 feet of the foundation. Irrigation should be limited to the amount sufficient to maintain vegetation. Application of more water will increase the likelihood of slab and foundation movements. Perimeter Drain A subsurface perimeter drain is recommended around portions of the structure which will have habitable or storage space located below the finished ground surface. This includes crawlspace areas but not the walkout trench, if applicable. A typical drain detail is presented in Figure 7. A subsurface perimeter drain is designed to intercept some types of subsurface moisture and not others. Therefore, the drain could operate properly and not mitigate all moisture problems relating to foundation performance or moisture intrusion into the basement area. Concrete Type FII cement is recommended for concrete in contact with the subsurface materials. Calcium chloride should be used with caution for soils with high sulfate contents. The concrete should not be placed on frozen ground. If placed during periods of cold temperatures, the concrete should be kept from freezing. This may require covering the concrete with insulated blankets and heating. Concrete work should be completed in accordance with the latest applicable guidelines and standards published by ACI. Foundation Configuration Remarks The configuration of the foundation system is critical to its performance. The position of foundation windows, jogs, steps and the relative elevation of adjacent and opposite walls can affect foundation performance. The nature of residential foundation construction does not allow for control of these conditions by the Foundation Design Engineer. Improper placement of the above can result in differential and lateral foundation movement not anticipated by the Geotechnical Engineer. The Foundation Design Engineer should be contacted regarding the foundation configuration. V City of Wheat Ridge ilding Diviso RMG — Rocky Mountain Group 6 Job No. 157033 3330 Chase St South Lot Wheat Ridge, Colorado General Remarks The recommendations provided in this report are based upon the subsurface conditions encountered in the test borings, anticipated foundation loads, and accepted engineering practices and principles in the area at the time of report preparation. No warranty is made or implied in this report that this firm has an all inclusive knowledge of every portion of the subsurface materials on or under the site. There is no evaluation detailed enough to reveal every subsurface condition. The nature and extent of variations across the site may not become evident until construction commences or thereafter. The construction process itself may also alter subsurface conditions. If variations appear evident at the time of construction, our office should be notified. If additional mass site grading is performed at the site which results in elevations that vary significantly from existing grades (more than plus or minus 2 ft), our office should be informed about these changes. If needed and/or if desired, we will reexamine our analyses and make supplemental recommendations. The recommendations are intended to reduce differential movement. However, it should be noted that geotechnical engineering recommendations are not an exact science. The recommendations presented in a geotechnical engineering report are not based only on the analytical and empirical tools but rely on engineering judgement as well. The fact that professional judgements must be used in making recommendations means that the conclusions and recommendations presented in a geotechnical engineering report should not be considered risk-free and, more importantly, are not a guarantee that the interaction between the soils and the proposed structure will perform as planned. Furthermore, it must be recognized that the foundation will undergo some movement on all soil types. Concrete floor slabs will likely move vertically. The recommendations for isolating floor slabs from columns, walls, partitions or other structural components should be implemented to mitigate potential damage to the structure. Subsequent owners should be provided a copy of this report. The recommendations are based on accepted local engineering practice and are intended for individuals familiar with local construction practices and standards. The owner is also encouraged to read A Guide to Swelling Soils for Colorado Homebuyers and Homeowners, Special Publication No. 43, available from the Colorado Geological Survey. Recommendations contained in the report are also applicable for prevention of settlement due to wetting of support soils. RMG does not assure the existence of and/or the compliance with the above recommendations. This is the responsibility of the client referenced on the first page. RMG provided recommendations only and does not supervise, direct or control the implementation of the recommendations. City of Wheat Ridge uilding Di RMG — Rocky Mountain Group 7 Job No. 157033 3330 Chase St South Lot Wheat Ridge, Colorado Senate Bill 13 This report may be partial fulfillment of Colorado Senate Bill 13 (1984), C.R.S. 6-6.5-101, The Soil and Hazard Analysis of Residential Construction, if the purchaser receives this report at least fourteen days prior to closing. The purpose of Senate Bill 13 is to inform the purchaser of the presence of expansive soil or hazards on the site. Geologic and environmental hazards are outside the scope of services of this report. Expansive soil and bedrock may result in movement of foundation components and floor slabs. The recommendations presented in this report are intended to reduce, not eliminate, these movements. The owner and builder should review and become familiar with Special Publications 43 issued by the Colorado Geologic Survey. This report and the recommendations contained therein are only valid if all parts of Senate Bill 13 are satisfied. Should you have questions, please do not hesitate to call. Cordially, RMG — Rocky Mountain Group Jeffrey Jones, P.E. Geotechnical Project Engineer 60- !Cccycs� �V�: 4/4/17 "0 4753 O�g'�98"a099947Pdp! P. 3031 11111M City cat Wheat ,8uildir�; Miss: RMG — Rocky Mountain Group 8 Job No. 157033 APPROXIMATE PROPERTY LINES .40 i 1Ywi IED L'ISION N W E S -i�- APPROXIMATE TEST BORING LOCATION NOT TO SCALE o� ARCHITECTS Cobrado Spdngs,CO 80918 IM(719) 5484=00 ��Mr_.080Eallood, CO 80112 xG ENGINEERS(3W) 688-NT5 Cm* CO ROCKY MOUNTAIN GROUP D E'er' WO(970)330-1071 AERIAL SITE MAP 3300 CHASE STREET SOUTH LOT DENVER,COLORADO MANN BUILDERS, LLC f,= a JOB. No. 157033 FIG. No. 1 DATE: 04.03.2017 SOILS DESCRIPTION FILL: CLAY, SANDY F-1 SANDSTONE UNLESS NOTED OTHERWISE, ALL LABORATORY TESTS PRESENTED HEREIN WERE PERFORMED BY: RMG - ROCKY MOUNTAIN GROUP 14 INVERNESS DR. EAST, SUITE E-136 ENGLEWOOD, COLORADO SYMBOLS AND NOTES STANDARD PENETRATION TEST - MADE BY DRIVING A SPLIT -BARREL SAMPLER INTO THE SOIL BY DROPPING A 140 LB. HAMMER 30", IN GENERAL ACCORDANCE WITH ASTM XX D-1586. NUMBER INDICATES NUMBER OF HAMMER BLOWS PER FOOT (UNLESS OTHERWISE INDICATED). UNDISTURBED CALIFORNIA SAMPLE - MADE BY DRIVING A RING -LINED SAMPLER INTO XX THE SOIL BY DROPPING A 140 LB. HAMMER 30", IN GENERAL ACCORDANCE WITH ASTM D-3550. NUMBER INDICATES NUMBER OF HAMMER BLOWS PER FOOT (UNLESS OTHERWISE INDICATED). �z FREE WATER TABLE -a DEPTH AT WHICH BORING CAVED eBULK DISTURBED BULK SAMPLE ItAUG AUGER "CUTTINGS" 4.5 WATER CONTENT (%) ROCKY MOUNTAIN GROUP JOB No. 157033 ARCHITECTS A�ilen RMG ehni� EXPLANATION OFFIGURE No. 2 Materials Tes4ng Forensics ,,,,Planning TEST BORING LOGS ENGINEERS r orado 2910 Ausrin BIuff, c,nnorrPa re y DATE 4/3/17 Hs ParM�ay CN'_ Spinys, CO 80918 (719)568-0600 SOUTHERN COLORADO. DENVER METRO. NORTHERN COLORADO B-1 L 0 z TEST BORING: B-2 LL 0 z FDATEDRILLED: p w w DATE DRILLED: JO W w = 00 a o O 3/15/17 = m a °- o w U) Q � of REMARKS: w � Q NO GROUNDWATER ON 0 ¢ NO GROUNDWATER ON 0O LU 3/17/17 m 3/17/17 m Fill: Lean Clay with Sand - brown Fill: Lean Clay with Sand - brown with debris, stiff, moist with debris, moist 11 20.2 50 21.( Sandstone - brownish gray and 5 bluish gray with oxidation 5 staining, medium hard to very hard, moist Sandstone - brownish gray and bluish gray with oxidation staining, medium hard to very hard, moist 50/8" 15.0 50/6" 14.' 10 10 50/6" 16.8 50/5" 15.° 15 15 50/6" 19.9 50/5" 13.; 20- 02550/5" 25- 50/5" 21.0 ROCKY MOUNTAIN GROUP ARCHITECTS A-ral u st aGeotechnical Sin luralRM G Malenals Testing Foren DIWI, Planning ENGINEERS ,�,.a�n � d- , .�,a a Oft.)2910 Austin BWlts Parkvmy C. Spings, CO 80918 NORTHERN COLORADO TEST BORING LOGS JOB No. 157033 FIGURE No. 3, 11,4heat Rici(;o , DAT cul ing , Test Boring No. Depth p WaterrY Content (0/6) DeDnsi ty (pco Liquid Limit - Plasticity Index o - o FHA /0 Ex Expansion Retained p Passing No. Pressure No.4 Sieve 200 Sieve s % Swell/ Collapse USCS Classification B-1 4.0 20.2 43 24 71.3 (719) 5480800 SOUTHERN COLORADO. DENVER METRO, NORTHERN COLORADO CL B-1 9.0 15.0 B-1 14.0 16.8 114.6 47 29 45.4 0.7 SC B-1 19.0 19.9 B-1 29.0 21.0 B-2 4.0 21.0 B-2 9.0 14.1 120.1 0.3 B-2 14.0 15.5 B-2 19.0 13.3 34.9 ROCKY MOUNTAIN GROUP ARCHITECTS ENGINEERS ArchitecWral Daotatl,nlral Structural ftMU Mstenals Tss4rg Forensics Ciol, Planning Cg2a Snmios ,C-1, 2910 Austin BAA(s Parkway Ctlorado Spiigs, CO 80918 (719) 5480800 SOUTHERN COLORADO. DENVER METRO, NORTHERN COLORADO SUMMARY OF LABORATORY TEST RESULTS JOB No. 157033 FIGURE No. 4 PAGE 1 QRidge DATE 4/3/17 -Ading Divison 100 90 1--80 W70 r c060 (D Z U)50 Q d 1--40 z Lu x30 w a 10 0 U.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS HYDROMETER 3 1.5 1 3/4 1/23/8 4 10 20 40 100 200 100 10 1 0.1 0.01 0.001 GRAIN SIZE IN MILLIMETERS COBBLES GRAVEL I SAND SILT OR CLAY coarse I fine I coarse medium fine Test Boring Depth (ft) Classification LL I PL PI • B-1 4.0 LEAN CLAY with SAND(CL) 43 19 24 m B-1 14.0 CLAYEY SAND(SC) 47 18 29 • B-2 19.0 Test Bori 0 B-1 B-1 A B-2 Depth (ft) %Gravel %Sand 4.0 14.0 19.0 ROCKY MOUNTAIN GROUP ARCHIT Awa- Go-h-A . Rm aees Teg Strias ENGINEERS CMI, PWarg cm t.6:, npnawo� Cla9inp, 00 809188 (/5CBO600 SOUTHERN COLORADO, DENVER METRO, NORTHERN COLORADO %Silt I %Clay 71.3 45.4 34.9 JOB No. 157033 SOIL CLASSIFICATIONI FIGURE No. 5 DATA DATE 4/3/17 2.0 1.0 0 0 U) z a x Lu -1.0 z 0 U) cn -2.0 D_ 0 U -3.0 -4.0 100 000 APPLIED RE - PSF PROJECT: 3330 Chase St. Wheat Ridge, CO SAMPLE DESCRIPTION: Clayey Sandstone NOTE: SAMPLE WAS INUNDATED WITH WATER AT 1,000 PSF 2.0 1.0 z 0 a -2.0 0 U -3.0 -4.0 I I I I I I I I I I 100 1,000 APPLIED PRESSURE -PSF PROJECT: 3330 Chase St. Wheat Ridge, CO SAMPLE DESCRIPTION: Clayey Sandstone NOTE: SAMPLE WAS INUNDATED WITH WATER AT 1,000 PSF ROCKY MOUNTAIN GROUP ARCHITECTS A` hIt—c Geotechnical Sttopo Materials Testing forenaice 001, Planning Kmu ENGINEERS Calorado Sonnos- /Commie OR ) 2910 AWBWHs Parkway C,.do Sp0gs, CO 80918 (E 0 SOUTHERN COLORADO, DENVER METRO, RO, NORTHERN COLORADO SAMPLE LOCATION: B-1 @ 14 FT NATURAL DRY UNIT WEIGHT: 114.6 PCF NATURAL MOISTURE CONTENT: 16.8% PERCENT SWELL/COMPRESSION: 0.7 SAMPLE LOCATION: B-2 @ 9 FT NATURAL DRY UNIT WEIGHT: 120.1 PCF NATURAL MOISTURE CONTENT: 14.1% PERCENT SWELUCOMPRESSION: 0.3 SWELL/CONSOLIDATION TEST RESULTS 10,000 10,000 JOB No. 157033 FIGURE No. 6 Wheat kiGge DATE 4/3/17,,/ 3" MIN PERFORATED �p PIPE (U.N.O.) GENERAL NOTES: 1. BOTTOM OF DRAIN PIPE SHALL BE AT OR BELOW BOTTOM OF FOOTING AT ALL LOCATIONS 2. ALL DRAIN PIPE SHALL BE PERFORATED PLASTIC, WITH THE EXCEPTION OF THE DISCHARGE PORTION WHICH SHALL BE SOLID, NON -PERFORATED PIPE. 3. MINIMUM GRADE FOR DRAIN PIPE SHALL BE 1%, OR 3 INCHES OF FALL IN 25 FEET. 4. DRAIN PIPE SHALL BE PROVIDED WITH A FREE GRAVITY OUTFALL, IF POSSIBLE. IF A GRAVITY OUTFALL CANNOT BE ACHIEVED, THEN A SUMP PIT AND PUMP SHALL BE USED. 5. ALL DRAIN COMPONENTS SHALL BE RATED/APPROVED BY THE MANUFACTURER FOR THE INSTALLED DEPTH AND APPLICATION 6. DRAIN SYSTEM, INCLUDING THE OUTFALL OF THE DRAIN, SHALL BE OBSERVED BY QUALIFIED PERSONNEL PRIOR TO BACKFILLING TO VERIFY INSTALLATION. Southern Office EXTERIOR BACK FILL ° P ARCHITECTS Colorado Springs,CO D ° D city 1 ° Z /O DD D Q \ oPOLYETHYLENE FILM SEALED TO WALL AND ° z __jEXTENDED AROUND BOTTOM OF GRAVEL ° o Q P \ COLLECTOR AS SHOWN ROCKY MOUNTAIN GROUP Greeley/Evans, CO 80620 D \D°P ° D ° 10" MIN 3" MIRAFI ® 140N GEOTEXTILE OR EQUIVALENT MIN - WRAP BOTTOM EDGE ALONG 3" POLYETHYLENE FILM AND WRAP TOP EDGE z MIN ALONG FOOTING (AS SHOWN) N GRAVEL COLLECTOR: GRAVEL SIZE TO BE AT LEAST 2X THE WIDTH OF SLOTTED PERFORATIONS OR 1.5X THE o D p ROUND FOOTING \\�\\� FOOTING D � PERFORATIONS D D ° 3" MIN PERFORATED �p PIPE (U.N.O.) GENERAL NOTES: 1. BOTTOM OF DRAIN PIPE SHALL BE AT OR BELOW BOTTOM OF FOOTING AT ALL LOCATIONS 2. ALL DRAIN PIPE SHALL BE PERFORATED PLASTIC, WITH THE EXCEPTION OF THE DISCHARGE PORTION WHICH SHALL BE SOLID, NON -PERFORATED PIPE. 3. MINIMUM GRADE FOR DRAIN PIPE SHALL BE 1%, OR 3 INCHES OF FALL IN 25 FEET. 4. DRAIN PIPE SHALL BE PROVIDED WITH A FREE GRAVITY OUTFALL, IF POSSIBLE. IF A GRAVITY OUTFALL CANNOT BE ACHIEVED, THEN A SUMP PIT AND PUMP SHALL BE USED. 5. ALL DRAIN COMPONENTS SHALL BE RATED/APPROVED BY THE MANUFACTURER FOR THE INSTALLED DEPTH AND APPLICATION 6. DRAIN SYSTEM, INCLUDING THE OUTFALL OF THE DRAIN, SHALL BE OBSERVED BY QUALIFIED PERSONNEL PRIOR TO BACKFILLING TO VERIFY INSTALLATION. Southern Office ARCHITECTS Colorado Springs,CO city 1 (719) 548-0600 RMG 4 Central Cnglewood,C ENGINEERS Englewood, CO 80112 PERIMETER DRAIN 19 �"' o. 7 (303)688-9475 Northern Office: ROCKY MOUNTAIN GROUP Greeley/Evans, CO 80620 (970) 330-1071 City of Wheat jjdgc COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 June 15, 2017 OFFICIAL ADDRESS CHANGE/NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: CURRENT ADDRESS: 3330 Chase Street NEW ADDRESS: 3330 & 3336 Chase Street SUBDIVISION: Columbia Heights LOT(s): 15, 16, 17, 18 SECTION: 25 PARCEL NO: 39-251-14-019 NOTES: This is a courtesy notification. AUTHORIZED BY: DATE: 6 / 14- 01— DISTRIBUTION: 1. Property Owner 2. Jefferson County Assessor, ATTN: Data Control, Lacey Baker email to lbaker@jeffco.us 3. Jefferson County Elections, ATTN: H. Roth, 3500 Illinois St., Laramie Building, Suite 1100, Golden, CO 80401 4. Email to Jeffco IT (Mapping) Services at smitchel@,ieffco.us and edelynkogjeffco.us 5. Jeffco Public Schools, ATTN: Communication Services, 1829 Denver West Dr., Bldg. 27, Golden, CO 80401 6. U.S. Post Office, 3700 Tennyson St.., Denver, CO 80212 7. Email to erlinda j.martinezguVs.goy and krissy.i.summerfield(a,usps.gov and arlene.a.vickreyLa)usps.gov 8. Xcel Energy, sandra.cardenas(a)xcelenerg 9. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 10. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 11. Wheat Ridge Water District 12. Wheat Ridge Sanitation District 13. West Metro Fire District 14. Wheat Ridge Planning Division 15. Wheat Ridge Building Division 16. Wheat Ridge Police Department 17. GIS Specialist 18. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.ci.wheatridge.coms DATE: Vicinity Map Site: 3330 Chase Street 3336 Chase Street ki City of Wheat Ridge Residential Demoliti PERMIT - 201601801 PERMIT NO: 201601801 ISSUED: 11/14/2016 JOB ADDRESS: 3330 Chase ST EXPIRES: 11/14/2017 JOB DESCRIPTION: Demolition of entire structure *** CONTACTS *** OWNER (812)219-9736 DOUGAL MURRAY GRAHAM LIVING TR GC (303)467-3366 Dave Stefanich 080140 All Demolition Excavation *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: / SUBDIVISION CODE: 2412 / LAKESIDE, STEWART GARDENS, OLI BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 4 000.00 FEES PAID Total Valuation 0.00 Demolition Fee 50.00 C q ** TOTAL ** 50.00 *** COMMENTS *** *** CONDITIONS *** All work shall comply with applicable codes and ordinances and is subject to field inspections. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am t e legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I urther attest that I am legally authorized to include all entities named within this document as parties to the work io be performed d that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNBC or CONTRACTOR _(Cir& one) Date I. This permit was issue ased on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180.days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this pen -nit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any d o applicable c r any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. * v. (_40& /) %16 6 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. Inspection time requests will be accepted by email only. Please email requests to insptime avi.wheatridge.co.us between 7:30am and 8:00am, the morning of the inspection. Please put the address of the inspection in the subject line. - City of dge ��Whcatlk MUNITY DEVELOPMENT Building & Inspection Services Division 7500 W. 29`t' Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: permits(a�ci.wheatridge.co.us FOR OFFICE USE ONLY Date: Plan/Permit # Plan Review Fee: Building Permit Application — Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ' Property Address: ' �6 0 Owner IIWLler $`i Phn -72 3,j, Property Owner Email: iLv 114 �l -, �, Co /y"'�� Mailing Address: (if different than property address) Address: S CAn1 - City, State, Zip: Architect/Engineer: Architect/Engineer E-mail: Contractor: 0 11 Phone: 7.� Contractors City License #: ham- � Phone: Contractor E-mail Address: �..4f��?e �. /) p, r Sub Contractors: Electrical W.R. City License # Other City Licensed Sub: City License # Plumbing: W.R. City License # Other City Licensed Sub: City License # Mechanical. W.R. City License # Complete all information on BOTH sides of this form ❑ COMMERCIAL P RESIDENTIAL Description of work: (Check all that apply) ❑ NEW COMMERCIAL STRUCTURE ELECTRICAL SERVICE UPGRADE ❑ NEW RESIDENTIAL STRUCTURE ❑ COMMERCIAL ROOFING ❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING ❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT ❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.) ❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT ❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT ❑ ELECTRICAL SYSTEM/APPLIAN E REPAIR or REPLACEMENT OTHER (Describe){�iyt��, (For ALL projects, please provide a detailed desc it p lot n of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc.) 1Je dYl D EO � �, P 5� C Sq. FULF Amps Btu's Squares Gallons Other Project Value: (Contract value or the cost of all materials and labor included in the entire project) OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT 1 hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that 1 assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that 1 am the legal owner or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any entity included on this application to list that entity on this application. 1, the ap licant for this building permit application, warrant the truthfulness of the information provided on the application.----` CIRCLE ONE: (OWNER) (CONTRAC7,,;t777:tav,5 of (OWNER( (CONTRACTOR) Electronic Signature (first and last name): DATE: / L/ DEPARTMENT USE ONLY ZONING COMMMENTS: OCCUPANCY CLASSIFICATION: Reviewer: BUILDING DEPARTMENT COMMENTS: Reviewer: Building Division Valuation: $ oF.00 yam% O * 1876 Colorado Department of Public Health and Environment DEMOLITION NOTIFICATION APPLICATION FORM APPLICATION FEE MUST ACCOMPANY THIS FORM INCOMPLETE APPLICATIONS WILL BE RETURNED (Notice will be mailed to the demolition contractor unless specified otherwise) Fee: $50 + $5 per 1000 ft2 of area to be demolished = $ 55- 00, (See instruction #1 on reverse side) Submit form to: Permit Coordinator Colorado Dept. of Public Health and Environment APCD-I E -B 1 4300 Cherry Creek Drive South Denver, CO 80246-1530 Phone: 303-692-3100 Fax: 303-782-0278 Asbestos@state.co.us ' Regulated asbestos -containing materials meahs (a) friable asbestos -containing material, (b) Category I nontnable ACM trial has becomemaw , Category I nonfriable ACM that will be or has b(en subjected to sanding, grinding, cutting , or abrading or (d) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this regulation. Note: Asbestos -containing sheet vinyl and linoleum must be properly C1Vr,7 abated/removed prior to demolition. =F 0142016 I Form: DNA08 l �� l�t =•-OIMI� �'�+� 7'A � /� Co any me: nwIi-+ '/ v� tFJ- V •VLA Ii Building Name D r et:�j�/ �% �y Square footage of footprin facility or portion of facility to be demolished +- L w Cit: /�� State: co Zi Code: �0 03 Street: o I �� " o Telephone (;0)467—A b Fax # (301 03 MO? ity: Cou - Zip Code. g,>z l U ,, o sect Manager: Cell Phone # (3 -96�� Proposed Sta �6 Proposed �mp "tion D�fe/ z/ 4 Method/MQans ofpemolition:aboutemaining _� _�� I certifJt!Tth_e Certified Asbestos Building Inspec orhas informed me E asbestos -containing materials in the facility to be tv 0 E demolished. t ® wrecking El Buming El Implosion El Moving [I Other, specify: Si tures Print Name: a A?hl 0 Landfill Rec#06g Building De — n ✓ t Burning requires additional authorization -Please call (303) 692-3100 and ask '/ �� to s Pak to the O en Rivninn Permit Coordinator General Abatement ContractgL(GAC) ` ner's Name LIA CDPHE Asbestos Permit # Total Quantity of Asbestos Remov Street: 33 So A'v- 0 i0 O 3 in 0 M Date Remo v I Corn I ted l G � Telephone # o ) �i� ( City: J L State: irvdt.ea7 ^� CID Zi Code: D I n 0) " Q 0 U C R Type(s) of Asbestos -Con aining Material Removed:,ontact's r�n� Name: Telephone # �^,,,C_ Mann iZ) 21 °° c,,tre With my signature below, I certify that I possess current AHERA accreditation and state of Colorado certification as o an Asbestos Building Inspector. I also certify that I have thoroughly inspected the facility to be demolished, as listed U in the Demolition Site block above, sampled all suspect materials, had all samples analyzed for the presence of CD asbestos by a NVLAP-accredited laboratory, and have determined that no Regulated ACM exists anywhere in the = facility.' I also certify that I have informed the owner/operator of the facility or the demolition contractor that any _ c •o asbestos -containing material allowed to stay in the facility must remain non -friable during demolition. Specify type(s) Mof ACM remaining, below: (check appropriate box(es)): as ;._ N ❑ Vinyl asbestos floor tile (VAT) ❑ VAT mastic EXTar/asphalt impregnated roofing ❑Asphaltic pipe coatings Q 0 .0 U ❑ Spray -applied tar coatings ❑ Caulking ❑ Glazing ❑ Other, specify: a> nature: (In Blue Ink) Printed Name: 1 Derek D'Avignon a� U Date of i a In�uecti O Cert # Expiration Date Telephone # Cell Phone # tl �(O / �.� 10177 10/7/1 (303) 382-1175 (303) 949-2965 1 verify that all refrigerants from air conditioning/refrigeration appliances have been properly recovered in accordance with AQCC Regulation No. 15 (for information on CFC requirements call 692-3100). 1 further verify that all luminous exit signs (containing radioactive material) have been tm L_ `0 disposed of in accordance with 6 CCR 1007-1 subpart 3.6.4.3 (for information on luminous exit sign requirements call 303-692-3320). ��— y ` CHECK THE APPROPRIATE BOX: m03 ❑ Building Owner Contractor E]Other Date: % _ _ m U Signature: ��� Print Name: 4-1 ((/ 9 /�jtil THI3/Box Is FOR CDPHE U E ONLY: Postmark or Hand Delivery Date: Approved By: Code: initial -310 transfer Form of Payment & #: j S p Permit #: Record # Date Issued: ' Regulated asbestos -containing materials meahs (a) friable asbestos -containing material, (b) Category I nontnable ACM trial has becomemaw , Category I nonfriable ACM that will be or has b(en subjected to sanding, grinding, cutting , or abrading or (d) Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this regulation. Note: Asbestos -containing sheet vinyl and linoleum must be properly C1Vr,7 abated/removed prior to demolition. =F 0142016 I Form: DNA08 l �� l�t =•-OIMI� �'�+� 7'A Or Current owner/Occupant Dougal Graham 3330 CHASE ST WHEAT RIDGE CO 80212-7038 Regarding Permit: 20060899; front porch 3330 Chase ST, Wheat Ridge, CO 80212 Our Records indicate that the above noted permit was issued on 09/22/06. Our last inspection related to that permit was on 02/28/07. Because of the inactivity on this permit, it will become void as of 12/31/2015. Please contact this office within one week from the date of this letter to update us on the status of this permit, or call for a final inspection on the property. You may call 303-234-5933 or request inspections online at www.ci.wheatridge.co.us. Information needed are permit number, property address, type of inspection and date to be inspected. If you do not contact this office, and wish to resume work at a later date, you will be required to submit a new permit application, drawings with appropriate code edition information and pay applicable fees. Incomplete or inactive permits may be reported to agencies such as Jefferson County Assessor, title companies, etc., and could affect future transactions related to this property. Thank you for your cooperation concerning this matter. If we can answer any questions, please don't hesitate to contact us at 303-235-2855, option 7. Sincerely, Melissa Mackey Senior Permit Technician COMMUNITY DEVELOPMENT DEPT. Inspection Services Division (303) 235-2855 Correction Notice Job Address: 33.Jo G!.Ik9S€' .... ~~ ~/~/"./C ".c;;N~ /. ~ ~..s-r~~ J"~..... L. .A/~7" ..A"~ ~LL \~.R~-5. 2,' e1~"".o A/~ /# S""'...-c-r .;'R:::JO'___ LJI.J!!F 72T ..sA/0';J- ':;'_"~_d <?'K'\"~ ~No7"' , ~ ~~ .//7,'/ ./A1'77a ;t..~.t:? AA:1r ~~b"'" /...v~~ When corrections have been made, call for re-inspection at 303-234-5933. Date: .::::7.?;Zc:f'cJ7 DO NOT REMOVE THI Inspector City of Wheat Ridge Res. Add Structure PERMIT - 060899 PERMIT NO, JOB ADDRESS, DESCRIPTION, 060899 3330 CHASE ST front porch ISSUED, EXPIRES, 09/22/2006 *** CONTACTS *** owner 303/233-4404 Dougal Graham ** PARCEL INFO ZONE CODE, SUBDIVISION, ** R-1C UA USE, BLOCK/LOT#, UA 0/ Permit Fee Plan Review Fee Total Valuation Use Tax ** TOTAL ** ESTIMATED FEES 82.16 53.40 .00 32.26 167.82 PROJECT VALUATION, 1,792.00 ** FEE SUMMARY ** C02!?:331 Comments: MR, R-1C CR, Okay Subject to 9/19/06 with notes field inspection I hereby certify that the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances, rules or regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown, and allegations made are accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.C) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. -~~~ Signat con ractorfowner 7'-:1.. .:l._6 date 1. This permit was issued in accordance with the provisions set forth in your application and is subject to the laws of the State of Colorado and to the zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. 2. This permit shall expire if (A) the work authorized is not commenced within sixty (60) days from issue date or (B) the building authorized is suspended or abandoned for a period of 180 days. 3. If this permit expires, a new permit may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have been or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. 4. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. 5. Contractor shall notify the Building Inspector twenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. 6. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the building codes or any other ordinance, law, rule or regulation. All plan review is subje to fie 'ons. //. date Signature of Chi~~~ INSPECTION REQUEST LINE: (303)234-5933 BUILDING OFFICE, (303)235-2855 REQUESTS MUST BE MADE BY 3PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. City of Wheat Ridge Community Development Department MiNOR BUILDING PERMIT APPLICATION ])0'" t: If L... t!J" t</Ol .4- ..1' ~ &:I c.. f/A!O. .. IIoMe OtNAlee-. Property Owner: Property Address: Contractor License No.: Company: IJ'" OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT ~ 06-0110'/ (/) ylL Building Permit Number: Date: PhoneJ6'-t..U- ~v~..., Phone: 111 Buildino Dear. Valuation Figure: $ 1 -"<, J hereby certify thai the setback distances proposed by this permit application are accurate, and do not violate applicable ordinances. rules or regulations of the City of Wheat Ridge or covenants, easements or iestrictions of record; that all measurements shown, and allegations made are accurate; that J have read and agree to abide by all . conditions printed on this application and that I assume full responsibility for compliance with the Wheat Ridge Building Code (I.B.G) and all other applicable Wheat Ridge Ordinances, for work under this permit. Plans subject to field inspection. (OWNER)(CONTRACTOR): SIGNED ...q:~ DATE 'f ..I a-...D~ (OWNER)(CONTRACTOR):PRINTEO 1>6 tI t; A /... G ttAI-4.A 1ft DATE 9-/;1..-1>/.. fA-. v ue:$ Permit Fee: Plan Review Fee:$ Use Tax:$ Total:$ Use of Space (description): ( ~f , h~L ~fECfEllVIEfD) Description of work: Ips , "~Gb .. 't,tf-z.:t.& SEP 1 ? ,OU6 Sq. Ft. added ~ ~ (., BUILDING DEPARTMENT USE ONLY ----- - .--- ~ONING COMMENTS: ~/~ 0V' --------------- Approval: 1/ Cl/ Zonlng: \ HOn? l I 4.]> 1\/ '",.'.'~"'m'" l: .." %2:.<~ ~ cQJ:3l tf\\ 0 3J 0 31 ~ Approval; - - .s:;"J, "- PUBLIC WORKS COMMENTS: ~I .t~'1JH Approval: ~IRE DEPARTMENT COMMENTS: Approval: Occupancy: Walls: Roof: Stories: Residential Units: This permit was issued in accordance wi!h the provisions set forth in your application and is subjeclto the laws of the State of Colorado and to the Zoning Regulations and Building Codes of Wheat Ridge, Colorado or any other applicable ordinances of the City. This permit shall expire if (A) the work authorized is nol commenced within sixty (60) days from issue date or (8) the building authorized is suspended or abandoned for a period of 180 days. If this permi! expires, a new permrt may be acquired for a fee of one-half the amount normally required, provided no changes have been or will be made in the original plans and specifications and any suspension or abandonment has not exceeded one (1) year. If changes have bE::en or if suspension or abandonment exceeds one (1) year, full fees shall be paid for a new permit. No work of any manner shall be done that will change the natural flow of water causing a drainage problem. Contractor shall notify the Building Inspector lwenty-four (24) hours in advance for all inspections and shall receive written approval on inspection card before proceeding with successive phases of the job. The issuance of a permit or the approval of drawings and specifications shall not be construed to be a permit for, nor an approval of, any violation of the provisions of the blJiJding codes or any other ordinance, law, rule or regulation. All plan review Is subject to field Inspections. Electrical License No: Company: Plumbing License No: Company: Expiration Date: Approval: Expiration Date: Approval: (1) (2) (3) (4) (5) (6) Chief Buildina Official Mechanical License No: Company: Expiration Date: Approval: 'f I i \ ~ ~ /". ---_._-,..._-~.~.[....._--_..._.~.- ._.._......~'--_..~, .-.--.... .- --.- . I , .~ ". , "J.O \ r (0.- " ft ;;l- ---"7"~ '. ' . 4 I:, i , .. ~~~,:~ It(-r ~ ..:1,6 . ~1{ A L Lf--/ / \ {- I I , If ~'1 r I ;.I< I I , ~ '/ r or ~ I" f i i I /0 ( 'f D I I (</"{'-~~ p~ /~(x'l /' n ,J P k' '""'_'__'_"~_' ------c:::: '~.-n..::t7 c.. [-i f+0? e- -- c: / ~ '>- >-1 I' i I , I 1 ~~*~~i{--~-~~S~~--~~- ~ ~,-L\~" - - ~- or~ _ ____ i --~.:;--.1;::-~ ._~ .p-;. ~',., - ,~ "l---. -r:. c::: ilL , I ~. ,~ ~, ~ I I I ') , , l'!~ "j- t'l- I:} l' ~ _.~ I , i i i I i , I I i I i I i I i i I , , , i I I i I I I 'I ~ /1\ ) : I i ' !~ 'K' ~ d r- <f t< (J' I i ~t~ ~ ~ ~'1~~.1 0 .... '" g-' ~~1"1 10,,4,\. , !a~,~~ %~.g,.g ~~..g,. r.i\\ I~'\f\~ I~\!\g,. i ~~~;:l >. \ '''''la~!_ \! i\'\\ ~ ,~ '::f' C1l ~ l'. 0- lC (\) 03 .. '"C s. ... - 00- < -. at':! o-lC o ,1) .., III l (\) ::s .. ~ >< ~ - Ei;' ,. o h <- ' Ct - V' -- ~- , ~ -90 /(~ - ---\:~ , j', ' , . ~ ~ ~ '0' ~\i (: ftt " 1- ,/ I ~ i ! i ] I ! \1. i I i , ! , . .~. _~.::d_~ r- ._' " 1.--- r~-" .::;' I I l?J 4. j 'J " ::: ! ~ 8 ~ \1 I 1 I ~ 'J ! 1 ! I ! i I i I I i I I I I ! , I I I I I ! - I .."....-~ ,~ ---0,1 is I r :1~ : ~ I I .ll 1 _!~~-: -~~ : '1 I ! I' I ;""..' --- I I I 1 ....].~:= :;'~....::.. ,. (j 0 ~ ::c: ~ :;7 - Z m 0 "'"' . ~ C-l. ~~ tx:l :::0 ....... r..n rJ'l c ,...... ~.:;' ~ c,~ - ~ ~}~ 4'y d-- l t ...;.(~ '0 < Cl'i - ~~. Z '"" ~~ a M 1" ." 0 ("1 " ~ 1---- ~ ~~. :./.~ t':!'~ ~ - ~!,; <:t-. 0<>-:;' ,,"'~'" -? . ,.. ,"\"4~~ --<,)(>; 71 C)1~t .:>:: ,. ~. :Z'~~ ;-:.: .' .=:.-;;: ~ - <:--1" 6o:'l-< ". ..c:. X" ""-- iJ' I I I ,I t Sec. 26-208. Residential-One C District (R-1C). City of Wheat Ridge Community Development 7500 W. 29'" Ave. Wheat Ridge, CO 80033 303-235-2846 www.ci.wheatridge.co.us A. Intent and purpose: This district is established to provide high quality, safe, quiet and stable, medium-density single-family residential neighborhoods, and to prohibit activities of any nature which are incompatible with the medium-density residential character. B, Development standards: TABLE INSET: Maximum Maximum Minimum Minimum Minimum Minimum Minimum Height Building Lot Lot Front Side Rear Coverage Area Width Yard Setback Yard Yard Setback{a) Setback(a) One-family dwelling 35' 40% 5,000sl 50' 3O~bl 5' 5' Group home 35' 40% 5,000 sf 50' 30~'1 5' 5' Accessory buildings(e) Detached garage or 15' 60051 5,000 sf 50' 30~'1 [1 if <= 8' in height; 10' if 5' if <= 8' in height; 10' if carport >S'in height >8'lnheight Private storage shed 10' 200s1 5,0008f 50' 30' S,(e) if<= 8' in height; 5'fel if<=8'inheighl; . 10'if>8'inheight 10'if>8'inheight Churches, schools, 35' 40% 1 acre 200' 30' 15' 20' government and quasi- government buildings, golf courses, small day care center, and nursing, elderly and congregate care homes All other uses 35' 40% 5,000 sf 50' 30'1'1 5'(c) 10' Notes: (a) Any side or rear yard which abuts a public street shall have a minimum setback of thirty (30) feet for all structures. (b) Front setbacks for structures on lots or portions of lots which abut cul-de-sacs may be reduced to ten (10) feet for those portions of lots which abut a cul-de-sac bulb, (See Figure 26-123.3.) (e) Any building or structure which houses animals, except a residence, shall be set back fifteen (15) feet from property lines and at least thirty (30) feet from a residence on an adjacent parcel. (d) Comer lots shall have a minimum lot width of eighty (80) feet for both street frontages. (e) Metal accessory buildings over 120 square feet in size are not permitted. (Ord. No. 2001-1215, !l1, 2-26-01; Ord. No, 1313, !l4, 10-27-03) http://livepublish.municode.com/2/lpext.dll/Infobase 7 II II d5 c/205c/20c8 ?fn=document - frame.htm&f=temp... 5/4/2004 " , 1.8H ! ,? Recorded at. ...V...\.2..9o'clock Reception NL~34.2.o. llM. ..JBNJ"~.",9.i!.L.,,_,"" mROBERTW.J:,IEW: otto j 7urD; ~ . 1441 ...Recordel". THIS DEED, Made this _Fifth day of ~ . J e.nUe.IY in the year of our Lord one thousand nille hundred and Sixty two between Tho:_'lCS Hontrose Gn1ham of the County of Californir and State of~~, of the first part, and Dougal Uu:rray 'J-1'2.l18J1 of the County of Los Angeles Jefferson and State of Colorado, of the second part, WITNESSETH, That the said part y of the first part, for and in consideration of the sum of --Ten Dollers DOLLARS, to the said part y of the fh'st part in hand paid by the said party of the second part, the receipt whereof is hereby confessed and acknowledged, ha 8 remised, released, sold, conveyed and QUIT CLAIMED, and by these presents doe S remise, release, sell, convey and QUIT CLAIM unto the said part y of the second part, his heirs, successors and assigns, forever, all the right, title, interest, claim and demand which the said pal't y of the first part ha S in and to the following described real estate situate, lying and being in the County of Jeffereon and State of Colorado, to-wit: Lots 1[:;,16,1'7,18, (FifteC:ll, sixteen, seventeen, eighteen) '21001: ;;.)even, Co1ut:tuin Heights, and all hlpl'OVel'-lents trlS:r801l. (NO REVENUE REQUIRED - LOVE AND AFFECTION) TO HA VB AND TO HOLD the same, together with aU and singular the appurtenances and privileges thereunto belonging or in anywise thereunto appertaining, and all the estate, right, title, interest and claim whatsoever, of the said part y of the first part, either in Jawor equity, to the only proper use, benefit and behoof of the said party' of the second part, 11is heirs and assigns forever. IN WITNESS WHEREOF, The said part y of the first part ha 8 hereunto set hi s and seal the day and year first above written. hand ':/~<42 )1dJ;~~~'~~L] Sig'neu, Sealed and Delivered in the Presence of _[SEAL) ..[SEAL) __.[SEAL) STATE OF:C~' California l L ^ I". County of 05 nge1es The foregoing instrument was acknowledged before me this A. D. 19 62 ,by* Thomas Montrose Graham Fiftjt day of January, My commission expires July 20, 1963 ..,~.~. ~"::'~'-"" , 19 . Witness my hand and of:flclallleaf, ~ 1 ,j I" . s~ ", ,r,} r .. ~. .l~ ~ ..~'..... /' ,';..;, :;j~' .' '-"/->,' . ~~~~,';' u,; --/A :, J /// .~ '.'" ~;;./?, L/..' w ~ ;"'..7' ~nkie Mitchel " _/. "'~ ....::b~~~.. . . ',;: FRANKIE MITC~'4;;{....t 'Robli/ My Commission ExP{(e&'~~~Je63' attQrne'i:l,;>_~&~ttth~~ PI~~r~ ~';,~~rso~n~i~~~~ 1~:e~~e~~lt'o~,O~tt.;;;:i~:I~~r.icre~:ogtJi~;~~~cf&roe;e:e~"petl~~ ~tW{;i ~~f~~t~tO~r': :J.Qt:~~~~te~~~~e~t~eA1B~fD~el~~1~uCh ott\cer or oUlee",. 90S the president or other,oWeers ot sueh <)orporatlon, nemlng It.-IHaUitOfll No. 938. QUIT CLAIM DEED. _Bl'adf,,,'d.Robln.on Prlntlnw Company. 1824~'6 Stout"Street, Denver, Colorado