HomeMy WebLinkAbout3242 Fenton Street° City of Wheat Ridge
Commercial Roofing PERMIT - 201709134
PERMIT NO: 201709134 ISSUED: 11/17/2017
JOB ADDRESS: 3242 Fenton ST EXPIRES: 11/17/2018
JOB DESCRIPTION: Commercial reroof remove and install 30yr dimensional asphalt shingle with
60sq pitch=4/12
3242-3248 Fenton St
*** CONTACTS ***
OWNER (720)495-3535 CHARLOTTE M. TAYLOR TRUST
SUB (303)437-5568 Garth Stevens 170649 North Tech Contracting LLC
*** PARCEL INFO ***
ZONE CODE: UA / Unassigned USE: UA / Unassigned
SUBDIVISION CODE: 101 / BLOCK/LOT#: /
*** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 20,000.00
FEES
Total Valuation 0.00
Use Tax 420.00
Permit Fee 362.80
** TOTAL ** 782.80
*** COMMENTS ***
*** CONDITIONS ***
In order to pass a final inspection on commercial elastomeric or similar type roofing, a
letter of inspection and approval from the manufacturer technical representative stating
that "the application of the roof at (project address) has been applied in accordance with
the installation instruction for (roof material brand name) roof covering" is required to
be on site at the time of final inspection.
Effective December 1, 2014, asphalt shingle installations require an approved midroof
inspection, conducted when 25-75 percent of the roof covering is installed, prior to final
approval. Installation of roof sheathing (new or overlay) is required on the entire roof
when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and
Mid -roof inspections may be called in at the same time, 100 percent of the sheathing must
be complete and 25-75 percent of the midroof may be complete. Asphalt shingles are required
to be fastened to the roof deck with a minimum of 6 nails per shingle. A ladder extending 3
feet above the roof eave and secured in place is required to be provided for all roof
inspections. Roof ventilation is required to comply with applicable codes and/or
manufacturer installation instructions, whichever is more stringent.
w _ City of Wheat Ridge
Commercial Roofing PERMIT - 201709134
PERMIT NO: 201709134 ISSUED: 11/17/2017
JOB ADDRESS: 3242 Fenton ST EXPIRES: 11/17/2018
JOB DESCRIPTION: Commercial reroof remove and install 30yr dimensional asphalt shingle with
60sq pitch=4/12
3242-3248 Fenton St
I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with
this permit. I further attest that I am legally authorized to include alI entities named within this document as parties to the work to be
performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one) Date
1. This permit was issued based on the information provided in the permit application and accompanying )Tans and specifications and is
subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures.
2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and
received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building
Official and may be subject to a fee equal to one-half of the original)ermrt fee.
3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard
requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of
the Chief Building Official and is not guaranteed.
4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6, The issuance or granting - f a permit shall not be const ed to be a permit for, or an approval of, an violation of any provision of any
applicable code or anynance or regtfi n o s risdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS NUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
City of
y Wheat1919.
COMMUNITy DEVELOPMENT
Building & Inspection Services Division
7500 W. 291h Ave., Wheat Ridge, CO 80033
Office: 303-235-2855 * Fax: 303-237-8929
Inspection Line: 303-234-5933
Email: permits(o)_ci.wheatridge.co.us
FOR OFFICE USE ONLY
Date:
Plan/Permit #
Plan Review Fee:
Building Permit Application
*** Please complete all highlighted areas on both sides of this form. Incomplete applications may not be processed. ***
Property Address•,?
Property Owner (please print): Phone: -%.; (�, -
Property Owner Email: Uy1a,_j
Mailing Address: (if different than property address)
Address
City, State, Zip:
Arch itectlEIng 1neer:
Architect/Engineer E-mail:
Phone:
Contractor: "r
Contractors City License Phone: - `( 3-) S _s -
Contractor
Contractor E-mail Address:
Sub Contractors:
Electrical:
W.R. City License #
Other City Licensed Sub:
City License #
Plumbing:
W.R. City License #
Other City Licensed Sub:
City License #
Mechanical:
W.R. City License #
Complete all information on BOTH sides of this form
COMMERCIAL ❑ RESIDENTIAL
Description of work: (Check all that apply)
❑ NEW COMMERCIAL STRUCTURE ❑ ELECTRICAL SERVICE UPGRADE
❑ NEW RESIDENTIAL STRUCTURE ff-COMMERCIAL ROOFING
❑ COMMERCIAL ADDITION ❑ RESIDENTIAL ROOFING
❑ RESDENTIAL ADDITION ❑ WINDOW REPLACEMENT
❑ COMMERCIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ RESIDENTIAL ACCESSORY STRUCTURE (Garage, shed, deck, etc.)
❑ MECHANICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ PLUMBING SYSTEM/APPLIANCE REPAIR or REPLACMENT
❑ ELECTRICAL SYSTEM/APPLIANCE REPAIR or REPLACEMENT
❑ OTHER (Describe)
(For ALL projects, please provide a detailed description of work to be performed, including current use of areas,
proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and
amount of materials to be used, etc.)
Sq. Ft./LF
Amps
�_e V—CDQ *—I -,�
Sv. .S\ , Cc-;, (--�) J t
cll�-61,
C
Btu's
Squares
Gallons
Other
Project Value: (Contract value or the cost of all materials and labor included in the entire project)
OWNER/CONTRACTOR SIGNATURE OF UNDERSTANDING AND AGREEMENT
I hereby certify that the setback distances proposed by this permit application are accurate and do not violate applicable ordinances, rules or
regulations of the City of Wheat Ridge or covenants, easements or restrictions of record; that all measurements shown and allegations made are
accurate; that I have read and agree to abide by all conditions printed on this application and that I assume full responsibility for compliance
with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application; that I am the legal owner
or have been authorized by the legal owner of the property to perform the described work and am also authorized by the legal owner of any
entity included on this application to list that entity on this application. I, the applicant for this building permit application, warrant the
truthfulness of the information provided on the application.
CIRCLEONE: (OWNER) (CONTRACTOR) or (AUTHORIZED REPRESENTATIVE) of (OWNER) (CONTRACTOR)
SilInature (first and last name): DATE
ZONING COMMMENTS:
Reviewer:
BUILDING DEPARTMENT COMMENTS:
Reviewer:
DEPARTMENT USE ONLY
OCCUPANCY CLASSIFICATION:
Building Division Valuation: $
INSPECTION RECORD
Inspection online form: http://www.ci.wheatridge.co.us/inspection
Cancellations must be submitted via the online form before 8 a.m. the day of the inspection
Inspections will not be performed unless this card is posted on the project site
Request an inspection before MIDNIGHT (11:59 PM) to receive an inspec ' n the foal wing business day
PERMIT: ��,� ADDRESS: �`
Foundation Inspections
Date
Inspector
Initials
Comments
102 Caissons / Piers
103 Footing / P.E. Letter
104 Foundation Setback Cert.
105 Stem Walls
106 Foundation wall Insulation
Do Not Pour Concrete Prior To Approval Of The Above Inspections
Underground / Slab Inspections
Date
Inspector
Initials
Comments
201 Electrical / Cable/ Conduit
202 Sewer Underground Int.
203 Sewer Underground Ext.
204 Plumbing Underground Int.
205 Plumbing Underground Ext.
206 Water Underground
it. P7 - 1-7
Do Not Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections
Rough Inspection
Date
Inspector
Initials
Comments
301 Rough Framing
302 Wall Sheathing
303 Roof Sheathing
304 Sheer Inspection
305 Insulation
306 Mid -Roof
it. P7 - 1-7
307 Metal / Lath / Stucco
308 Rough Electrical Residential
309 Rough Electrical Commercial
310 Electrical Meter Residential
311 Electrical Meter Commercial
312 Temp. Const. Meter
313 Rough Plumbing Residential
314 Rough Plumbing Commercial
315 Shower Pan
SEE OVER FOR ADDITIONPI INSPECTIONS
PERMIT:,�Pj ADDRESS: ,��� fi?K661JOB CODE: (VC
Rough Inspection (continued)
Date
Inspector
Initials
Comments
316 Rough Mechanical Residential
317 Rough Mechanical Commercial
318 Boiler / Furnace
319 Hot water tank
320 Drywall screw and Nail
321 Moisture board / shower walls
322 Rough Grading
323 Miscellaneous
- 7 —
Final Inspections
Date
Inspector
Initials
Comments
402 Gas Meter Release
403 Final Electrical Residential
404 Final Electrical Commercial
405 Final Mechanical Residential
406 Final Mechanical Commercial
407 Final Plumbing Residential
408 Final Plumbing Commercial
409 Final Roof
- 7 —
410 Final Window/Door
411 Landscape/Park/Planning*
Inspections from these entities shall be requested
one week in advance.
*For landscaping and parking inspections please
call 303-235-2846
**For ROW and drainage inspections please call
303-235-2861
***For fire inspections please contact the Fire
Protection District for your project.
412 Row/Drainage/Public Works**
413 Flood plain Inspection**
414 Fire Insp. / Fire Protection***
415 Public Works Final**
416 Storm Water Mgmt.**
417 Zoning Final Inspection*
418 Building Final Inspection
Note: All items must be completed and approved by Planning, Public Works, Fire and Building
before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not
constitute authorization of occupancy.
For Low Voltage permits please be sure that rough inspections are completed by the Fire District and
Electrical low voltage by the Building Division.
�a
i CITY 6F WHEAT RIDGE
Building Inspection Division
(303) 234-5933 Inspection line
(303) 235-2855 Office • (303) 237-8929 Fax
INSPECTION NOTICE
Inspection Type: -3 0 t- - .
Job Address: 3 Lf S -,L
Permit Number: _ p 1'� y ► LI
❑ No one available for inspection: Time = -31 AM M
Re -Inspection required: Yes No
When corrections have been made, call for re -inspection at 303-234-5933
Date: I217 Inspector: 72