HomeMy WebLinkAbout3626 Newland StreetInspection online form: http://www.cli.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request /�n ins /c�ti before MIDNIGHT (11:59 PM) to re/ceiye an ins ection,th following business day 7E)r AERIV�I�; / VCT% ' ADDRESS � �`� ,�/1 /,��iA ��i _� inR r0DE: U i �%rte iundation Inspections Date Inspector Initials Comments %} Caissons / Piers Initials 1 Footing / P.E. Letter 4 Foundation Setback Cert. 5 Stem Walls 4 i Foundation wall Insulation Not Pour Concrete Prior To Approval Of The Above Inspections '. Jerground / Slab Inspections Date InsInt alsor Comments 2,:> E7ectrical / Cable/ Conduit 20: Sewer Underground Int. 20E :Sewer Underground Ext. ,204 lumbing Underground Int. p=lumbing Underground Ext. 2&6 ;?later Underground Po viot Cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections 1 Ip=y� _1h Inspection Date Inspector Comments ! Initials .p Rough Framing lck; 2 Vfall Sheathing � 4 i _'03 Roof Sheathing i -Ory •S.I eer Inspection J3 1;r*;ulation F_ . s ` ! -06 MA -Roof '3i ?A-tal / Lath / Stucco Ral!', ugh Electrical Residential oO 'fit; agh Electrical Commercial s a 'T" _lectrical Meter Residential ! :1 ;de,.trical Meter Commercial >12 ern P. Const. Meter Rough Plumbing Residential 14-igh Plumbing Commercial 315 Shower Pan r1I-i e�I.` r w= ., o l()lei: PERMIT(�� ADDRESS: , Z � � JOB CODE:6W Rough Inspection (continued) Date Inspector Initials Comments 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector Initials Comments 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door 411 Landscape/Park/Planning* Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 **For ROW and drainage inspections please call 303-235-2861 ***For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works** 413 Flood plain Inspection** 414 Fire Insp. / Fire Protection*** 415 Public Works Final** 416 Storm Water Mgmt.** 417 Zoning Final Inspection* 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. 1-7 i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line __:�9�(303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: Cl 0 9 - I Job Address: 1, A{c .,, a,, C Permit Number: 2 0 1-7 c q S`3 0 I r') C\ ❑ No one available for inspection: Time j V; a -3 M PM Re -Inspection required: Yes Veo When corrections have been made, call for re -inspection at 303-234-5933 Date: ► f- i -s Inspector: -7--b DO NOT REMOVE THIS NOTICE 1 i CITY OF WHEAT RIDGE Building Inspection Division i� 97(303) (303) 234-5933 Inspection line 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: "3 G �, - 11 1 , �l ) Job Address: �9 to L' & W l a ,, j -7L Permit Permit Number: —d 0 1 '7 0 cj 5` 3 v M1 1 c) -P ❑ No one available for inspection: Time R = _3$ AM PM Re -Inspection required: Yes So When corrections have been made, call for re -inspection at 303-234-5933 Date: i -D 9 g//-7Inspector: —)_/b DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201709530 PERMIT NO: 201709530 ISSUED: 12/11/2017 JOB ADDRESS: 3626 Newland ST EXPIRES: 12/11/2018 JOB DESCRIPTION: Residential reroof remove and install GAF Timberline HD asphalt shingles with 18sq pitch=6/12. *** CONTACTS *** OWNER (303)237-8539 THORN DANIEL F SUB (303)880-1542 Vaughn Tromburg 100242 Reliable Roofing *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 7,000.00 FEES Total Valuation 0.00 Use Tax 147.00 Permit Fee 156.75 ** TOTAL ** 303.75 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. 4 City of Wheat Ridge Residential Roofing PERMIT - 201709530 PERMIT NO: 201709530 ISSUED: 12/11/2017 JOB ADDRESS: 3626 Newland ST EXPIRES: 12/11/2018 JOB DESCRIPTION: Residential reroof remove and install GAF Timberline HD asphalt shingles with 18sq pitch=6/12. I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permit. I further est that I am le ally authorized to include alI entities named within this document as parties to the work to be performed and that work to be per rmed is disclosed in this document and/or its' accompanying approved plans and specifications. (2-I&-1--� Signature of OWNER or CONTRACT e) Date 1. This permit was issued based on the information provided in thepermit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, po plans and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a changeof the natural flow of water without prior and specific approval. 5. The permit holder shall notify'the Building and Insp&tift Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable cod' or any ord naa nce nr re uI ti n of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. La enia Reimer From: no-reply@ci.wheatridge.co.us Sent: Monday, December 11, 2017 10:21 AM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in �- the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Single Family Home are on the property? PROPERTY INFORMATION Property Address 3626 newland 'greet Property Owner Name clan thorn Property Owner Phone 3032378539 ` Number (enter WITH dashes, eg 303-123-4567) Property Owner Email n/a Address LJ)'37 S Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Yes 3626 newland roof contract .pdf CONTRACTOR INFORMATION Contractor Business Name Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone Number (enter WITH dashes, eg 303-123-4567) Contractor Address (Primary address of your business) Contractor Email Address Retype Contractor Email Address reliable roofin 100242 3038801542 8266 s logan court littleton, co 80122 vaughntromburg@hotmail.com vaughntromburg@hotmail.com DESCRIPTION OF WORK TOTAL SQUARES of 18 the entire scope of work: Project Value (contract 7000 value or cost of ALL materials and labor) Are you re -decking the No `. roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) Pitched roof (2:12 pitch or greater) N What is the specific pitch, 6:12 of the PITCHED roof? How many squares are 18 part of the PITCHED roof? Describe the roofing gaf timberline HD --,-"-'--- materials for the PITCHED roof: Type of material for the PITCHED roof. Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) Asphalt j r house SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application Yes Yes Yes Yes 3 and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant vaughn tromburg reliable roofing Email not displaying correctly? View it in your browser. 4 Vaughn Tromburg 8.256 S..I ,ogan Court Littleton, l2O (303) 880-1542 Reliable Roofing Roof Quote Work to be Performed at: 3626 Newland Street `�v%' ieai Ridge, Cv 80033 November 14, 2017 The following work to be completed at the above address: jpr Roofing House: 18.20 sq_ IKO Cambridge asphalt dimensional shingle installed class 3 = $7000.00 Permit fee reimbursed by insurance with receipt INCLUDES: 30 lb felt underlayment, Ice and water shield in roof valleys and 2 feet past exterior walls Double felt on low slopes front and back All roof jacks, flashings, caps and protrusions replaced 120 degree 2 x 4 drip edge on all eve ends (drip edge to match shingle) 90 degree 2x2 drip edge on all rake ends (drip edge to match shingle) Waste removal, tear off l layer existing roofing Attic ventilation installed All Roof Vent Jacks Sealed and Painted All work done to city codes Includes 20 year leak guarantee Balance due = $7000.00 plus pe -Mit fee (upon_ completion/pending inspection) ", Thank You. We Appreciate Your Business! Lo'� / t 0 p i