Loading...
HomeMy WebLinkAbout7400 W. 48th CircleINSPECTION RECORD Inspection online form: http://www.ci.wheatridge.co.us/inspection Cancellations must be submitted via the online form before 8 a.m. the day of the inspection Inspections will not be performed unless this card is posted on the project site Request an inspection before MIDNIGHT (11:59 PM) to receive an inspectio the followi g business day PERMIT � / ( `Z'z� ADDRESS:LkadODE: (�f� Foundation Inspections Date Inspector Initials Comments 102 Caissons / Piers 103 Footing / P.E. Letter 104 Foundation Setback Cert. 105 Stem Walls 106 Foundation wall Insulation �- uo Not Pour concrete Prior To Approval Of The Above Inspections Underground / Slab Inspections Date Inspector Initials Comments 201 Electrical / Cable/ Conduit 202 Sewer Underground Int. 203 Sewer Underground Ext. 204 Plumbing Underground Int. 205 Plumbing Underground Ext. �- 206 Water Underground Do Not cover Underground or Below / In -Slab Work Prior To Approval Of The Above Inspections Rough Inspection Date Inspector Initials Comments 301 Rough Framing 302 Wall Sheathing 303 Roof Sheathing 304 Sheer Inspection 305 Insulation �- 306 Mid -Roof 307 Metal / Lath / Stucco 308 Rough Electrical Residential 309 Rough Electrical Commercial 310 Electrical Meter Residential 311 Electrical Meter Commercial 312 Temp. Const. Meter 313 Rough Plumbing Residential 314 Rough Plumbing Commercial 315 Shower Pan SEE OVER FOR ADDITIONAL INSPECTIONS n PERMIT:% ADDRESS: . ✓ink % v� �JOB CODE: Rough Inspection (continued) Date Inspector CommentsInitials 316 Rough Mechanical Residential 317 Rough Mechanical Commercial 318 Boiler / Furnace 319 Hot water tank 320 Drywall screw and Nail 321 Moisture board / shower walls 322 Rough Grading 323 Miscellaneous Final Inspections Date Inspector CommentsInitials 402 Gas Meter Release 403 Final Electrical Residential 404 Final Electrical Commercial 405 Final Mechanical Residential 406 Final Mechanical Commercial 407 Final Plumbing Residential 408 Final Plumbing Commercial 409 Final Roof 410 Final Window/Door ' 411 Landscape/Park/Planning" Inspections from these entities shall be requested one week in advance. *For landscaping and parking inspections please call 303-235-2846 "For ROW and drainage inspections please call 303-235-2861 **'For fire inspections please contact the Fire Protection District for your project. 412 Row/Drainage/Public Works" 413 Flood plain Inspection— 414 Fire Insp. / Fire Protection' 415 Public Works Final" 416 Storm Water Mgmt."* 417 Zoning Final Inspection` 418 Building Final Inspection Note: All items must be completed and approved by Planning, Public Works, Fire and Building before a Certificate of Occupancy is issued. Approval of the Final Building Inspection does not constitute authorization of occupancy. For Low Voltage permits please be sure that rough inspections are completed by the Fire District and Electrical low voltage by the Building Division. i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE �I Inspection Type: `7 0 q A D F Job Address: %yfX 14/ ytqtn t" ,'O Permit Number: 2-0/ go 0' i' d- -- ❑ No one available for inspectio : e / l AM/PM Re -Inspection required: Yes o When correct' ns have been made, c r re -inspection at 303-234-5933 Date: / inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 234-5933 Inspection line (303) 235-2855 Office • (303) 237-8929 Fax INSPECTION NOTICE Inspection Type: 3�, Job Address: -710PermitNumber: 9_0 a, _ ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, call for re -inspection at 303-234- Date:—//9///4 03-234- Date: / Inspector: y_47 DO NOT REMOVE THIS NOTICE City of Wheat Ridge Residential Roofing PERMIT - 201800222 PERMIT NO: 201800222 ISSUED: 01/23/2018 JOB ADDRESS: 7400 W 48th CIR EXPIRES: 01/23/2019 JOB DESCRIPTION: Residential Reroofing permit to remove and install Owens Corning TruDefinition Storm Asphalt Shingles with 27 squares pitch= 5/12. Duplex7400-7420 W 48th Circle *** CONTACTS *** OWNER (720)314-2844 BLP LLC SUB (720)314-2846 Roger Peterson 020791 PHI Homes Inc. *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 12,253.00 FEES Total Valuation 0.00 Use Tax 257.31 Permit Fee 251.85 ** TOTAL ** 509.16 *** COMMENTS *** *** CONDITIONS *** Midroof & Final Roof inspections for ROOFS 6/12 PITCH & OVER: 3rd party inspection will be required for both the midroof and final inspections. The 3rd party inspection report AND THE ORIGINAL PERMIT CARD needs to be dropped off to the Permit Desk at the City of Wheat Ridge. The report MUST BE SIGNED by the Homeowner. REGARDING ROOF VENTILATION: Roof ventilation shall comply with IBC Sec. 1203.2 or IRC Sec. R806. The installation of ridge venting requires the installation or existence of soffit venting. For calculation purposes, one hat or turtle vent equal to one-half of one square foot of opening. Effective December 1, 2014, asphalt shingle installations require an approved midroof inspection, conducted when 25-75 percent of the roof covering is installed, prior to final approval. Installation of roof sheathing (new or overlay) is required on the entire roof when spaced or board sheathing with ANY gap exceeding one half inch exists. Sheathing and mid -roofs may be called in at the same time, one hundred percent of the sheathing must be complete and 25-75 percent of the mid -roof may be complete. Asphalt shingles are required to be fastened to the roof deck with a minimum of 6 nails per shingle. Ice and water shield is required. Eave and rake metal is required. A ladder extending 3 feet above the roof eave and secured in place is required to be provided for all roof inspections. Roof ventilation is required to comply with applicable codes and/or manufacturer installation instructions, whichever is more stringent. In order to pass a final inspection of elastomeric or similar type roof coverings, a letter of inspection and approval from the manufacturer technical representative stating that "the application of the roof at (project address) has been applied in accordance with the installation instruction for (roof material brand name) roof covering" is required to be on site at the time of final inspection. City of Wheat Ridge Residential Roofing PERMIT - 201800222 PERMIT NO: 201800222 ISSUED: 01/23/2018 JOB ADDRESS: 7400 W 48th CIR EXPIRES: 01/23/2019 JOB DESCRIPTION: Residential Reroofing permit to remove and install Owens Corning TruDefinition Storm Asphalt Shingles with 27 squares pitch= 5/12. Duplex7400-7420 W 48th Circle i, by my signature�ereby attest th work to be performed shall comply with all accompanying approved plans and specifications, applicable bbuilding c des, and all a ica e municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal o, the property nd authorized to obtain this permit and perform the work described and approved in conjunction with this_permit. I,furtl}dr attest that I ally authorized to include all entities na ed within this document as parties to the work to be performed at all work to ed is disclosed in this docu ent and or its' accompanying approved plans and specifications. 20 Signature of ER or CONTRA OR (Circle one) Date I. This pern�it as issued based on the information provided in the permit application and accompanying plans and specifications and is subject fo th compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This petmittshall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received` icor to the date of expiration. An extension of no more than 180 days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the originalpermit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees androcedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4, No work of an manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a perit shall not be construed to be a permit for, or an approval of, any violation of any provision of any applicable code or any ordmancg u r regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official' —, Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. 1/22/2018 Owner/Agent BLP LLC Phone 303-955-1552 Property Location 7400-7420 W 48th Cir Wheat Ridge, CO 80033 PHI Homes, Inc 11953 W 56th Cir Arvada, CO 80002 Contract 720-314-2846 PHI Homes will remove shake roof and install Class 4 IR Owens Corning shingle Tear -off is 27 squares Contractor to install 16 soffit vents 8x16 and two additional 12" Turbine vents to meet balanced roof venting Refer to Lomanco printout using 2637 sq ft gross attic space. Ice and water shield added to reach minimum 24" over conditioned space. Material and Labor 12,253.00 Decdking may be requirted after tear off if spacing between roof lath exceeds 1/2" per city code Contract Total 12,253.00 Warranty The roof shall have a five (5) year fully transferable workmanship warranty The roof material shall have a limited lifetime warranty as described by Owens Corning Terms and Acceptance of Agreement Terms PHI Homes will provide material and labor to complete the Restoration for the sum of Twelve Thousand -Two Hundred -Fifty -Three and no/100 Dollars ($12,253.00) to be paid as follows: On Completion of all work to Customer satisfaction. Owner/Agent _ Signed date Page 1 of 1 1/22/2018 'D AN �._ENTSissawwow Vent Calculator Vent Calculator Alt Lomanco attic ventilation product requirements are based on the minimum standard 1/300 rule as set i international Residential Code (IRC). If local code requires the 1/150 rule, please double the requirements. L on the 1/150 rule. Choose your exhaust system and enter area to ventilate. (Attic floor space in square feet) Turbines ENTER AREA TO VENTILATE: 2637 'sq ft. Required Exhaust NFA(1/300 Rule): 633 sq in. 1/22/2018 Exhaust Units >>> C816 105/190 140 SV -10 DA -4 IV -9 Vent Calculator TURBINES ALL -12" 4 Intake Units Needed For Chosen Exhaust �16 15 12 17 29 29 All Lomanco attic ventilation product requirements are based on the minimum standard 1/300 rule as set i International Residential Code (IRC). If local code requires the 1/150 rule, please double the requirements. L on the 1/150 rule. Copyright 1999 - 2017 Lomanco, Inc. Privacy Back to Top httpJlwww.lomanco.com/vent-resourcestvent-calculator 2/2 Dina Kem From: no -reply@ ci.wheatridge.co.us Sent: Monday, January 22, 2018 12:03 PM To: CommDev Permits Subject: Online Form Submittal: Residential Roofing Permit Application Residential Roofing Permit Application This application is exclusively for new permits for residential roofs and for licensed contractors only. This type of permit is ONLY being processed online --do not come to City Hall to submit an application in person. Permits are processed and issued in the order they are received and due to the volume of requests, time to process varies and is subject to change. YOU WILL BE CONTACTED WHEN YOUR PERMIT IS READY FOR PICK-UP AND WILL BE GIVEN A SPECIFIC DATE AND TIME WINDOW TO COMPLETE THE TRANSACTION. You will be notified if your contractor's license or insurance has expired, and you may update those documents at the time you are issued your permit. For all other requests: Homeowners wishing to obtain a roofing permit must apply for the permit in person at City Hall. Revisions to existing permits (for example, to add redecking) must be completed in person at City Hall. All other non -roofing permits must be completed in person at City Hall. The Building Division will be open from 7:30-10:30 a.m., Monday through Friday to process these types of requests. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN REROOFING UNTIL PERMIT HAS BEEN ISSUED. Is this application for a Yes residential roof? How many dwelling units Duplex are on the property? PROPERTY INFORMATION Property Address Property Owner Name Property Owner Phone Number (enter WITH dashes, eg 303-123-4567) 7400-7420 West 48th Circle BLP LLC 720-314-2844 Property Owner Email pyrot.rentals@gmail.com / Address S6 �, l Do you have a signed contract to reroof this property? Applications cannot be submitted without an executed contract attached below. Attach Copy of Executed Contract Yes 7400-7420 Roof Contract scan.pdf CONTRACTOR INFORMATION Contractor Business PHI Homes Inc Name Contractor's License 020791 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contractor Phone 720-314-2846 Number (enter WITH dashes, eg 303-123-4567) Contractor Address 11953 W 56th Circle (Primary address of your business) Contractor Email Address roger. phi. homes@gmail.com Retype Contractor Email Address DESCRIPTION OF WORK roger. phi. homes@gmail.com TOTAL SQUARES of 27 the entire scope of work: 1 Project Value (contrac 12,253 value or cost of ALL materials and labor) Are you re -decking the roof? Is the permit for a flat roof, pitched roof, or both? (check all that apply) No Pitched roof (2:12 pitch or greater) 2 What is the specific pitch of the PITCHED roof? How many squares are part of the PITCHED roof? Describe the roofing materials for the PITCHED roof: Type of material for the PITCHED roof: Provide any additional detail here on the description of work. (Is this for a house or garage? Etc) 5/12 Owens Corning TruDefinition Storm ,/ Asphalt J Main House re -roof plus added venting i SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that this application is NOT a permit. I understand I will be contacted by the City to pay for and pick up the permit for this property. I understand that work may not begin on this property until a permit has been issued and posted on the property. I certify that I have been authorized by the legal owner of the property to submit this application Yes Yes Yes Yes 3 and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Name of Applicant Roger Peterson Email not displaying correctly? View it in your browser.