HomeMy WebLinkAbout9990.5 W 51st PlacePROJECT DESCRIPTION • INSTALL NEW 30'-0"f SABRE METAL POLE (PROVIDED BY CIVIL CONTRACTOR) • INSTALL (1) CANISTER ANTENNA ON NEW MOUNT • INSTALL (2) RRH UNITS INSIDE METAL POLE • INSTALL (1) ELECTRICAL METER INSIDE METAL POLE • INSTALL (1) LOAD CENTER INSIDE METAL POLE PROJECT INFORMATION SITE ADDRESS: 9990.5 W 51 ST PLACE ZONING DISTRICT: R-3 XCEL CONVERSATION#: PENDING WHEAT RIDGE, CO 80002 ADJACENT PARCEL #:39-153-00-006 POLE #: N/A LATITUDE: 39.790137 EXISTING PROPOSED LONGITUDE: —105.109043 POLE TYPE: N/A TYPE 3 GROUND ELEVATION: 5394 POLE COLOR: N/A RAL#9017 ANTENNA TIP HEIGHT: 29'-6" (TRAFFIC BLACK) NODE USID: 255533 ATTACHMENTS COUNTY: JEFFERSON COUNTY LUMINAIRE: N/A N/A (1) 6'-0" COBRAHEAD JURISDICTION: CITY OF WHEAT RIDGE SIGNAGE: N/A N/A NEAREST INTERSECTION: KIPLING ST DRAWING INDEX 14828325-COL0707OF_R02 -T-1 14828325-COL0707OF_R02 -A-1 14828325-COL0707OF_R02 -A-2 14828325-COL0707OF R02 -A-3 14828325-COL0707OF R02 -RF-1 14828325-COL0707OF_R02 -RF-2 14828325-COL0707OF_R02 -E-1 14828325-COL0707OF_R02 -G-1 14828325-COL07070F RO2 -GN-1 TITLE SHEET OVERALL SITE PLAN ENLARGED EQUIPMENT PLAN EXISTING & NEW METAL POLE ELEVATIONS RF & EQUIPMENT DETAILS RF & EQUIPMENT DETAILS ELECTRICAL ONE LINE DIAGRAM GROUNDING DETAILS GENERAL NOTES REV AI AM Am AM N Am AM N AM SABRE FOUNDATION DRAWINGS DATED 5/7/19 ARE ADDED AS AN ADDENDUM TO THIS DRAWING PACKAGE SITE PHOTO I Q SITE PROJECT PARTICIPANTS NAME COMPANY A&E CHRIS WOLFE TELCYTE SAC BRIAN GRAY SMARTLINK GROUP RF CLAUDIO POZZI AT&T WIRELESS POWER COMPANY CHELSEY FAYERWEATHER XCEL ENERGY TEL. COMPANY JIM MCGEE AT&T MOBILITY SERVICES LLC r . 0 0 wr\ r- 0-% 833-835-2983 303-548-6384 303-249-9073 715-533-2668 720-891-3935 Reviewed for Zoning Compliance by the City of Wheat Ridge Planning Division APPROVED BY: DATE: 6/15/2021 COMMENTS: complies with small cell standards �Nlheal o gyp, U = CD o CLUSTER NAME: CRAN RUTH.ARVDA SITE ID: COL0707OF R 02 NODE USIDO. 255533 COORDINATES: 39.790137, -105.109043 SITE ADDRESS: 9990.5 W 51ST PLACE CONSTRUCTION DRAWINGS (PICO) a..,.t&t Mobility cty or -Wheat idge COMMUNITY DEVELOPMENT "REVIEWED FOR CODE COMPLIANCE" These drawings were reviewed under the applicable laws in effect at the time of submittal. Reasonable effort was exercised in checking for code compliance. The stamping of these documents shall not be construed to be a permit for, or an approval of any violation of state and/or local codes, ordinances or amendments thereto. Plan Reviewer MTheisen Date 06/15/2021 DIRECTIONS APPLICABLE BLDG. CODES AND STANDARDS DIRECTIONS: (161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112: SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND TAKE 1-25 N 16.4M1. USE THE RIGHT 2 LANES TO TAKE EXIT 214A FOR INTERSTATE 70 LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT TOWARD AIRPORT/LIMON/GRAND JUNCTION 0.8M1. KEEP LEFT AT THE FORK, FOLLOW ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. SIGNS FOR 1-70 W/GRAND JCT AND MERGE ONTO 1-70 W 6.6 MI. TAKE EXIT 267 FOR KIPLING ST TOWARD CO -391 0.2 MI, KEEP RIGHT AND MERGE ONTO KIPLING ST 135 BUILDING CODE: FT. MERGE ONTO KIPLING ST 276 FT, CONTINUE STRAIGHT TO STAY ON KIPLING ST 0.3 [INTERNATIONAL BUILDING CODE (IBC), 2015 AS ADOPTED BY THE LOCAL JURISDICTION] MI. TURN RIGHT ONTO W 51ST PL, YOUR DESTINATION WILL BE ON THE RIGHT 89 FT. (POLE # N/A). ELECTRICAL CODE: Vada Station 19 Apartments nders Jack in the Box 19 Verizon 9 N VICINITY MAP .3c W 53rd Ave CL Y � 4 7 a' 3 rr,.�,�Mesa Verde lent Homes .Q V) MCI � DIG INFO CALL COLORADO ONE CALL (800) 922-1987 CALL 3 WORKING DAYS BEFORE YOU DIG! [NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 — 2007, NATIONAL ELECTRICAL CODE, 2017 AS ADOPTED BY THE LOCAL JURISDICTION] LIGHTNING PROTECTION CODE: [NFPA 780 — 2002, LIGHTNING PROTECTION CODE] SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING W 53rd STANDARDS. AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, THIRTEENTH EDITION ANSI/TIA 222—G, STRUCTURAL STANDARDS FOR ANTENNA SUPPORTING STRUCTURES AND ANTENNAS. 52a, TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF ELECTRONIC EQUIPMENT IEEE C2 NATIONAL ELECTRIC SAFETY CODE, LATEST VERSION TELCORDIA GR -1275, GENERAL INSTALLATION REQUIREMENTS W 5191 ANSI T1.31 1, FOR TELECOM — DC POWER SYSTEMS — TELECOM, ENVIRONMENTAL PROTECTION FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. UTILITY WORK MUST BE IN ACCORDANCE WITH THE FOLLOWING PUBLIC WORKS RULES AND REGULATIONS: • RULES AND REGULATIONS GOVERNING THE PRIVATE DESIGNING, PLANNING, CONSTRUCTION, RECONSTRUCTION, AND REMODELING OF GENERAL PUBLIC IMPROVEMENTS • RULES AND REGULATIONS GOVERNING STREET CUTS AND ROADWAY EXCAVATION SPECIFICATIONS NORTH • TRANSPORTATION STANDARDS AND DETAILS FOR THE ENGINEERING DIVISION SCALING DRAWINGS SUBCONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. IF USING 1111"x`17" PLOT, DRAWINGS WILL BE AT HALF SCALE. at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlink 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 1 16� 11 1 16- N 11145TRUETUP S.ERIAI CES 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL0707OF_RO2 SITE NAME CRAN_RUTH_ARVDA SEAL o�POp REG/s F k EXP :Q: r � .10/31/21021: Sol 3 JUN 2021 U M > N LOw Ld w cn Q CMz �� z O w D_ U Z� D :2J Q cin 0- :2Q =)W :2 O Of U z N 0 O U 0 (n W p � w U ~ � U 0 N DZ XW M a a U 0 C� W o W Y U w r U oo ao rn rn rn rn J N On mO Q \ N \ N \ O � O C%4 CO\ Z O O O O O of LLLd O W O N r7 o SHEET TITLE TITLE SHEET SHEET NUMBER T-1 PLAN NOTES: 1. ALL EXISTING DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY NEW POLE LOCATION, RIGHT OF WAY AND EXISTING UTILITY LOCATION PRIOR TO COMMENCEMENT OF WORK. 2. VERIFY ELECTRICAL AND FIBER DESIGN WITH UTILITY PROVIDER DESIGN AND STANDARDS. 3. CONTRACTOR TO REPLACE AND REPAIR ANY LANDSCAPING OR ASSOCIATED WATERING SYSTEMS DAMAGED DURING CONSTRUCTION. o OkNlheal gyp, V: , `eco 0 �G11%69 U `111 c I I W (E) UNDERGROUND ELECTRICAL I W I w I I (E) ROAD R.O.W. (N) POWER ROUTE (FINAL ROUTE TO BE DETERMINED IN FIELD PRIOR TO CONSTRUCTION WITH UTILITY LOCATES) GG G G G G G W 51 ST PL. I I G— G G - °I (E) UNDERGROUN CATV LI N E I (E) OVER HEAD ELECTRICAL 30 30 30 O\__ (E) EDGE OF _G G G G G G— ASPHALT (E) UNDERGROUND GASLINE — G G (E) rL ROAD I ENLARGED EQUIPMENT PLAN (E) EDGE 0 � I ■ ASPHALT __j ---(E) UNKNOWN UTILITY I � u rnT/� _ (E) SIDEWALK -------_ �—-------------- --------------------- (N) 30'-0"± SABRE METAL POLE COORDINATES: 39.790137, -105.109043 SITE ADDRESS: 9990.5 W 51ST PLACE (E) ROAD d R d "3 R.O.W. W (E) FIRE HYDRAN d IR M M M M c W I I W OVERALL SITE PLAN (E)TREE TYP. LEGEND UTI LITI ES USP BURIED POWER LINE BURIED GAS LINE OHr OVERHEAD TELEPHONE LINE UGT BURIED TELEPHONE LINE WW BURIED WATER LINE ss BURIED SANITARY SEWER so BURIED STORM DRAIN OHP OVERHEAD POWER LINE LANDSCAPE DITCH LINE/FLOW LINE ROCK RETAINING WALL VEGETATION LINE — x — x x — CHAIN LINK FENCE El WOOD FENCE BARBED WIRE FENCE RAILROAD TRACKS EDGE OF ROAD/STREET - - CENTERLINE OF ROAD/STREET — — PROPERTY LINE - - RIGHT—OF—WAY CENTERLINE --- --- RIGHT—OF—WAY LINE -------- ADJACENT BOUNDARY LINE --- --- SECTIONAL BREAKDOWN LINE AT&T SITE PROPERTY SUBJECT BOUNDARY LINE SYMBOL KEY mO0 N 0 k <T�p Know what's below. Call before you dig 1-800-424-5555 FULL SCALE 1 " = 10' (22x34 SHEET ONLY) 20' 10' 0 10' NORTH HALF SCALE 1 " = 20' (1107 SHEET ONLY) 20' at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlink 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 16— v l . � NFRASTRur–TuPE """CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN—RUTH—ARVDA SEAL r'z�_.-;�4444563 :TF�9Fo , EXP 0,x••.10/31/2021; /ON SIGNED, 3 JUN 2021 U FIRE HYDRANT D4 GATE VALVE ® WATER METER FIRE STAND PIPE CATCH BASIN, TYPE ® CATCH BASIN, TYPE 11 E TRANSFORMER 0 LIGHT STANDARD © POWER VAULT ® UTILITY BOX 0 UTILITY POLE c__ POLE GUY WIRE GAS VALVE GAS METER MT TELEPHONE VAULT o TELEPHONE RISER r SIGN O BOLLARD C3 MAIL BOX 23� SPOT ELEVATION mO0 N 0 k <T�p Know what's below. Call before you dig 1-800-424-5555 FULL SCALE 1 " = 10' (22x34 SHEET ONLY) 20' 10' 0 10' NORTH HALF SCALE 1 " = 20' (1107 SHEET ONLY) 20' at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlink 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 16— v l . � NFRASTRur–TuPE """CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN—RUTH—ARVDA SEAL r'z�_.-;�4444563 :TF�9Fo , EXP 0,x••.10/31/2021; /ON SIGNED, 3 JUN 2021 U m ocn > LO w W W cm U) [IfV) O w U Z Q co 0-: m_ w :2Q:2� O Z (n 0 O O OJ O W ~ OZ m Z U U v O Q O M N O O X W J m M Q J O w C.D W W y Y U W U J N On m Q O \ N \ N \ O O N c\o Z O O O O O OfLL W O W O N D SHEET TITLE OVERALL SITE PLAN SHEET NUMBER Ami oOkNlheal gyp, v = CD � ng ❑111�y�oc 1 G G G G G G G G G G G G G G G G G G G G G G G G G G G G G�G-1- �� G G G G G G G G G G G G G G G G 1 1 (E) UNDERGROUND GASLINE 1 1 (E) rL ROAD (N) POWER ROUTE (FINAL ROUTE TO BE R ' DETERMINED IN FIELD PRIOR TO 1 CONSTRUCTION WITH UTILITY LOCATES) (E) SIDEWALK W 51 ST PL. m 0 m a, O (N) (1) 2" CONDUIT FROM HH I V) __4 O TO TRANSFORMER 1 D � 1 (E) EDGE OF ASPHALT N (N) 30'-0"± SABRE METAL POLECA m (E) UNDERGROUND COORDINATES: 39.790137,-105.109043 I D CATV LINE SITE ADDRESS: 9990.5 W 51ST PLACE CANuG CATVuG CA CANuG U U U U CATVuG U U — U CANOG U U �p don � \ (E) ROAD (E) UNKNOWN UTILITY R.O.W. _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - z _ _ _ — — — — --------------- (N) (2) 2" CONDUITS FROM HH z NJ TO POLE FOR POWER -TRENCH APPROX 3' z _M M M -Al M M ENLARGED EQUIPMENT PLAN (E) OVER HEAD ELECTRICAL I° Flo F 5 (E) SIDEWALK CATVuG CaTy' CAI U CANuG U U U (N) (2) 24"X36" HAND HOLES (NEWBASIS # FCA243624T-00006) OR APPROVED EQUAL -------- ---------- ----------- (N) (2) 2" CONDUIT FROM HH TO POLE FOR FIBER -TRENCH APPROX 3' (E) TREE TYP. FU LL SCALE 1/4" = 1 '-0" (22x34 SHEET ONLY) 8' 4' 0 4' 8' N4 x1oo, H; ;; sHE� SCALE 1/8" = 1'-0" NORTH at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 tsmartlink 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 16- 16- v l 116- INFRASTRUCTURE """CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN—RUTH—ARVDA SEAL r'z�_.-;�4444563 :�9Fo EXP � ,x'•.10/31/2021; FSS�O -N. -A. SIGNED, 3 JUN 2021 U m ocn > LO w W w cm z o 0 [IfZ O w U 0� Z w Q co � m � w � O Z _j Q:2� (n 0 O U OJ O W ~ �Z m Z U U v Q O M N X W J m M Q U J o o w Y U W U Lu N On m Q \ N \ N \ O O N coo Z O O O O O 0 LL W O N SHEET TITLE ENLARGED EQUIPMENT PLAN SHEET NUMBER A-2 NOTES: 1. POLE TO BE PROVIDED BY CIVIL CONTRACTOR 16" NOTE: ALL PROPOSED AT&T ANTENNA, MOUNTING HARDWARE AND EQUIPMENT TO BE PAINTED MEDIUM GREY, RAL COLOR CODE 7038 PER THE APPROVED JURISDICTIONAL COLOR. (N) (1) 24"X14"0 CANISTER ANTENNA INSIDE (N) 16"0 CONCEALMENT SHROUD (N) (1) RRH UNIT INSIDE (N) 16"0 CONCEALMENT SHROUD Q z z Iz J W O Z � Q w Z Q � It Luw w U) cn z Z U W U I m ( Q e -N Q .-. z �-. Z Z v LL_ O LL_ O F-: O O O Lij I � w 0 10.750 � U I o rn a N (N) AT&T RF EQUIPMENT INSIDE (N) 30'-0"± METAL POLE BASE -(2) RRH UNITS 00 N -(1) DIPLEXER -(1) FID -(1) LOAD CENTER O(N) METER (N) DISCONNECT (E) SIDEWALK 16„ FOUNDATION REVEAL CANNOT (E) SIDEWALK EXCEED 3" ABOVE GRADE (N) 24"X36" HAND HOLE (NEWBASIS # FCA243624T-00006) OR APPROVED EQUAL I I (E) CONCRETE ' CONDUITS FROM CURB GUTTER () HAND HOLES TO POLE 8GUTTER -� -TRENCH APPROX 3' (N) FOUNDATION - 1 (SEE FOUNDATION DRAWING I I BY SABRE FOR DESIGN CRITERIA) al I es > L�-_�— �aJ FULL SCALE 1/2 = 1 -09e FULL SCALE (2204 SHEET ONLY) (2204 SHEET ONLY) 4' 2' 0 2' 4' 4' 2' 0 HALF SCALE 1/4" = 1'-0" HALF SCALE (1107 SHEET ONLY) (1107 SHEET ONLY) EXISTING WEST METAL POLE ELEVATION 11 1 NEW WEST METAL POLE ELEVATION 1/2$f = 1'-0" 2' 4' 1/49' = 1'-0" 2 at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlink 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 INFRASTRUCTUPE SEPVICEI 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL0707OF_RO2 SITE NAME CRAN_RUTH_ARVDA SEAL o�POp REG/s F ,T 4459Fo EXP 10/31/2021 ON A k - SIGNED, NAk- SIGNED, 3 JUN 2021 U m 0 LO(n W W U)N [ifW zz000�w� Q M � � m J � w� Q :2O U O Z m 0 O U OJ � V) W p w U ~ U 0 cv o j�0Xw m aOfa U 0 CD W o w Y U W U oo a0 O � O O J N On m Q \ N \ N \ O O N c\O z O O O O o 1.201 LL w tYl 0 w O N n SHEET TITLE EXISTING & NEW METAL POLE ELEVATIONS SHEET NUMBER A-3 (2) NOTICE SIGNS MUST BE PLACED OPPOSITE EACH OTHER BELOW THE ANTENNA RF SIGN TO BE INSTALLED BELOW ANTENNA NOTE: INSTALL PER MANUFACTURER SPECIFICATIONS AND FCC. PART # R893RPE-7 NOTES: • LABEL WILL BE 1.5"X 6" AND HAVE THE EMERGENCY NUMBER AND SITE LOCATION INFORMATION. • PLACE THE LABEL/STICKER ABOVE THE EQUIPMENT SIDE DOOR. PART NUMBER DESCRIPTION IN CASE OF EMERGENCY, OR PRIOR TO PERFORMING MAINTENANCE ON THIS SITE, CALL 800-638-2822 & REFERENCE USID NUMBER 255533 ow Moblllty OMLO`""' at&t POW -j W, S32DC0001 RF TRANSPARENT SHROUD 1 AT&T OPERATES ANTENNAS AT THIS STRUCTURE. S31 BB0001 ABOVE THIS POINT YOU ARE ENTERING AN AREA 1 WHERE RADIO FREQUENCY (RF) FIELDS MAY EXCEED S32AA0002 THE FCC GENERAL POPULATION EXPOSURE LIMITS. 1 FOLLOW SAFETY GUIDELINES FOR WORKING IN AN c0 RF ENVIRONMENT. 1 KEEP AWAY FROM THE FRONTS OF THE ANTENNAS. S32BA0001 CONTACT AT&T AT 800-638-2822, OPT. 9, 3 AND 1 FOLLOW THEIR INSTRUCTION PRIOR TO PERFORMING S21 CI0001 ANY MAINTENANCE OR REPAIRS ABOVE THIS POINT 1 THIS IS AT&T SITE USID 255533 S32CB0001 BASE COVER ASSEMBLY 1 (2) NOTICE SIGNS MUST BE PLACED OPPOSITE EACH OTHER BELOW THE ANTENNA RF SIGN TO BE INSTALLED BELOW ANTENNA NOTE: INSTALL PER MANUFACTURER SPECIFICATIONS AND FCC. PART # R893RPE-7 NOTES: • LABEL WILL BE 1.5"X 6" AND HAVE THE EMERGENCY NUMBER AND SITE LOCATION INFORMATION. • PLACE THE LABEL/STICKER ABOVE THE EQUIPMENT SIDE DOOR. BASE OF POLE N o� W heat CD �G��a`ng 5VO 0 15"f WEIGHT W/0 MOUNTING HARDWARE 30.86 LBS ACE - ACOM-2F15D-18P-C-R2 ANTENNA DETAIL STRUCTURE HEIGHT = 29'-4" BOTTOM OF BASEPLATE TO TOP OF SHROUD 013.00 29'-7» AGL 7r 7r 71 �� �� 1 25'-1 1/2"—,,, 3 24'-7" � 10.75 RF WARNING SIGNS & LABELS 1 5 1 1 1 NOKIA BAND 46 2T 1W LAA RRH DETAIL MILBANK U4801—XL-5T9 GE GED—TG3222R 5 70� 4,_9„ 6 O Z O 0 O 3" BTM OF w BASE PLATE 0" GROUND LINE X25.00 4 1 SABRE POLE BASE DESIGN DETAIL N 0 BOTTOM VIEW 1 1.61 " SIDE VIEW [�i �L�I�T_tjI�•�il_1���[�Z������:��I�r,1I� WEIGHT W/0 MOUNTING HARDWARE 14.33 LBS ITEM NO. PART NUMBER DESCRIPTION IN CASE OF EMERGENCY, OR PRIOR TO PERFORMING MAINTENANCE ON THIS SITE, CALL 800-638-2822 & REFERENCE USID NUMBER 255533 ow Moblllty OMLO`""' at&t 1 S32DC0001 BASE OF POLE N o� W heat CD �G��a`ng 5VO 0 15"f WEIGHT W/0 MOUNTING HARDWARE 30.86 LBS ACE - ACOM-2F15D-18P-C-R2 ANTENNA DETAIL STRUCTURE HEIGHT = 29'-4" BOTTOM OF BASEPLATE TO TOP OF SHROUD 013.00 29'-7» AGL 7r 7r 71 �� �� 1 25'-1 1/2"—,,, 3 24'-7" � 10.75 RF WARNING SIGNS & LABELS 1 5 1 1 1 NOKIA BAND 46 2T 1W LAA RRH DETAIL MILBANK U4801—XL-5T9 GE GED—TG3222R 5 70� 4,_9„ 6 O Z O 0 O 3" BTM OF w BASE PLATE 0" GROUND LINE X25.00 4 1 SABRE POLE BASE DESIGN DETAIL N 0 BOTTOM VIEW 1 1.61 " SIDE VIEW [�i �L�I�T_tjI�•�il_1���[�Z������:��I�r,1I� WEIGHT W/0 MOUNTING HARDWARE 14.33 LBS ITEM NO. PART NUMBER DESCRIPTION QTY. 1 S32DC0001 RF TRANSPARENT SHROUD 1 2 S31 BB0001 TOP MOUNT ASSEMBLY 1 3 S32AA0002 CABLE SKIRT ASSEMBLY 1 4 S23BA0001 DENVER PICO EXTENSION POLE 1 5 S32BA0001 TRANSITION SKIRT 1 6 S21 CI0001 16" BASE SECTION WELDMENT 1 7 S32CB0001 BASE COVER ASSEMBLY 1 8 SF00029 7' FOUNDATION 1 M at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlink 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 rs v ■ 16-16-4-08 ■ 16- I" F "ASTRUCTUP, ""V'r- 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN—RUTH—ARVDA SEAL EXP 21 �O N� SIGNED, 3 JUN 2021 U m 0 > LO 07 w w w N z 0 z O W m U Z w a - D Q M a- :2=)w 00 :2Q Z V) :2O 0 U � O O w ~ OZ m D_ Z 0 U U N o 48� QO S N<�=-i p x w m M 0 Q U O w U o_ o w Y U w r U N On m Q O \ N \ N \ O O N Z O O O O O cr LLW0 w0 N ro� D D' SHEET TITLE RF & EQUIPMENT DETAILS SHEET NUMBER RF=1 TOP VIEW 3-1/811 FRONT VIEW AT-PTA7 - Install SCALE 1:2 ANTENNA MOUNTING PLATE BILL OF MATERIALS TOTAL SHIP WT=15.1# SHIP MARK PC MARK QTY. DESCRIPTION LENGTH REMARKS BLACK WT GALV. WT AT-PTA7 - 1 PLUS -STYLE POLE ADAPTER WLDMNT 11" WELD 14.6 15.1 i5" (2) 0.58" HOLES ON A 07" B.C. FOR PLUS -STYLE POLE EXTENSION 16" HOLES ?)8.56" B.C. x-100219-0 EXTENSION kv ISO VIEW 0 at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlinl.. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 *" - I I =-I f"' v -r Ic r � `tee a 1 0— INF`R 413--MUETLJK2E ERIAI CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN_RUTH_ARVDA SEAL O�PQ� REG/s F ,T N4459Fo EXP 0�F.10/31/2021; Ss/O NAL_ SIGNED, 3 JUN 2021 U m ocn > LO w w � w !0- cm V) o 0 Z O W m UZ 0 w =)Q M � =)w � _j Q :2 O � U O z V) 0 O U 0 V) w � p w U ~ � U cv o�=)5 x m a Q U 0 0 m w Y y U w r U 00 00 O O) O O J N On m Q O \ N \ N \ O O N C\O Lo Z O O O O O LL w O W O N C)0 SHEET TITLE GENERAL NOTES SHEET NUMBER RF=2 NO. FROM TO CONFIGURATION MAXIMUM INCOMING ELECTRICAL PROPOSED FUSIBLE CONDUCTORS AND 70'-0" SERVICE P.O.C. SAFETY SWITCH CONDUIT PER UTILITY VOLT PROPOSED FUSIBLE PROPOSED METER (3) #1 CU THWN-2 AWG SAFETY SWITCH 3% PROPOSED METER PROPOSED AC LOAD (3) #1 CU THWN-2, #10 AWG CENTER (1) #6 CU EGC SITE NAME: AT&T SMALL CELL-PICO SITE NUMBER: VOLTAGE: 240V BUSS RATING: 125A MAIN BREAKER: 100A ENCOLSURE TYPE: NEMA 3R PANEL STATURS: PROPOSED PROPOSED LOAD VOLT (2) #14 CU THWN-2, @ 6.7A CENT R RADIO #1 (1) #14 CU EGC PROPOSED LOAD 3% (2) #14 CU THWN-2, DROP CENT R RADIO #2 (1) #14 CU EGC PROPOSEDCENTER LOAD (2) #14 CU THWN-2, RADIO #3 (1) #14 CU EGC PROPOSED AC LOAD W (2) #14 CU THWN-2, W CENTER INTERNAL FAN (1) #14 CU EGC NOTES: 1. ALL NEW CONDUCTOR WIRE TO BE INSTALLED SHALL BE COPPER THWN-2, THW-2, RHW-2, XHHW-2 WIRE UNLESS NOTED OTHERWISE. 2. ALL INSTALLED CONDUCTORS AND SIGNAL CABLES SHALL BE CLEARLY MARKED "AT&T SMALL CELL" WITH BRASS OR FIBERGLASS TAGS. 3. ALL GROUNDING AND BONDING TO BE PER THE RECOGNIZED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). ELECTRICAL ONE LINE DIAGRAM INCOMING POWEF SOURCE LE DR )V, 10, CU EGC PER 250.66 )WELD 12" BELOW SDE TO 5/8" x 10' IG COPPER -CLAD )UND ROD kNEL 'ED VIRE 120VAC FEEDER CONDUCTOR MAXIMUM DISTANCE #14 AWG 70'-0" 3% VOLT DROP @ 6.7A #12 AWG 135'-0" 3% VOLT DROP © 6.7A #10 AWG 225'-0" SITE NAME: AT&T SMALL CELL-PICO SITE NUMBER: VOLTAGE: 240V BUSS RATING: 125A MAIN BREAKER: 100A ENCOLSURE TYPE: NEMA 3R PANEL STATURS: PROPOSED 3% VOLT DROP @ 6.7A #8 AWG 345'-0" 3% VOLT DROP @ 6.7A NOTES: 1. ALL NEW CONDUCTOR WIRE TO BE INSTALLED SHALL BE COPPER THWN-2, THW-2, RHW-2, XHHW-2 WIRE UNLESS NOTED OTHERWISE. 2. ALL INSTALLED CONDUCTORS AND SIGNAL CABLES SHALL BE CLEARLY MARKED "AT&T SMALL CELL" WITH BRASS OR FIBERGLASS TAGS. 3. ALL GROUNDING AND BONDING TO BE PER THE RECOGNIZED EDITION OF THE NATIONAL ELECTRIC CODE (NEC). ELECTRICAL ONE LINE DIAGRAM INCOMING POWEF SOURCE LE DR )V, 10, CU EGC PER 250.66 )WELD 12" BELOW SDE TO 5/8" x 10' IG COPPER -CLAD )UND ROD kNEL 'ED VIRE at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlinl.. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 r � `tee a 9 � INF`R lt5Tnu ETLJK2E ERIAI CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN_RUTH_ARVDA SEAL O�PQ� REG/s F ,T 4459Fo EXP 1/2021.. Ss�o NAL.�� SIGNED, 3 JUN 2021 U PANEL MODE: SIEMENS W040ML1 125, 120/240 VOLT, 1 -PHASE, 3 -WIRE SITE NAME: AT&T SMALL CELL-PICO SITE NUMBER: VOLTAGE: 240V BUSS RATING: 125A MAIN BREAKER: 100A ENCOLSURE TYPE: NEMA 3R PANEL STATURS: PROPOSED m �(n > LO W W � W ! cm z o 0 z a- z O W m U 0 z Q M � J � W :2� Q :2o � U O z 0 O U 0 _j (n p � w U ~ U0 NLu o�j�oXw m a Q U 0 cKT LOAD DESCRIPTION BREAKER AMPS BREAKER POLES BREAKER STATUS SERVICE LOAD (VA) DEMAND FACTOR USAGE FACTOR PHASE "A" (VA) PHASE "B" (VA) USAGE FACTOR DEMAND FACTOR SERVICE LOAD (VA) BREAKER STATUS BREAKER POLES BREAKER AMPS LOAD DESCRIPTION cKT 1 RADIO#1 10 2 NEW 90 1.25 1.00 225 1.00 1.25 90 NEW 2 10 RADIO #3 2 3 10 NEW 90 1.25 1.00 ... 225 1.00 1.25 90 NEW 10 4 5 RADIO#2 10 2 NEW 90 1.25 1.00 130 1.00 1.25 14 NEW 1 10 INTERNAL FAN 6 00 10 NEW 90 1.25 1.00 112.5 J BLANK 335 338 VA N m O � m \ 0.69 2.89 \ \ at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlinl.. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 r � `tee a 9 � INF`R lt5Tnu ETLJK2E ERIAI CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN_RUTH_ARVDA SEAL O�PQ� REG/s F ,T 4459Fo EXP 1/2021.. Ss�o NAL.�� SIGNED, 3 JUN 2021 U m �(n > LO W W � W ! cm z o 0 z a- z O W m U 0 z Q M � J � W :2� Q :2o � U O z 0 O U 0 _j (n p � w U ~ U0 NLu o�j�oXw m a Q U 0 c� a- 0 W Y U W U 00 00 O O) O O J N m O � m \ \ \ N Lo z x 0 0 0 0 0 LL W > O W O N ro� SHEET TITLE DETAILS & SPECIFICATIONS SHEET NUMBER E-1 NOTES: • IF A SINGLE GROUND ROD DOES NOT HAVE A RESISTANCE TO GROUND OF 25 OHMS OR LESS, IT SHALL BE SUPPLEMENTED BY AN ADDITIONAL GROUND ROD. SEPARATION BETWEEN GROUND RODS MUST BE AT A MINIMUM DISTANCE OF 6' A A 6015 ICE 1_5 BARE #6 SOLID GROUND WIRE RAN IN POLE 24"-36" NEW PVC STUB OUT 0 rn r -RADE GROUND ROD S/S NUT S/S LOCK WASHER S/S FLAT WASHER ROUND WIRE #6 AWG 3CW SOLID, TINNED 5/8" GROUND ROD CLAMP WITH SHEAR HEAD GROUND ROD COPPER CLAD STEEL 5/8"0 X 8'-0" LONG 6'-0" MIN BARE #6 SOLID GROUND WIRE SINGLE LUG COMPRESSION LONG BARREL CONNECTOR GROUND BLOCK BARE #6 SOLID GROUND WIRE 6 1 GROUND CONNECTIONS 6. 1 " MIN.V 1/8" NOTE: 3CONNECT" GROUND BAR INTERCONNECTS AND EQUALIZERS. ac- FINISHE #2 AWU JULIU BTCW CONDUCTOR EXTERIOR GROUNDING RING 5 1 GROUND LOOP DETAIL qND HOLE PER )ESIGN BY OTHERS " WIDE SLOT FOR ROUNDING 3ONDUCTOR EXTEND I-" ABOVE GROUNDING 3ONDUCTOR 5/4" CRUSHED STONE OR EQUAL -ILL HANDHOLE TO WITHIN 2" OF TOP OF GROUNDING LOOP CONDUCTOR LEGEND: 1- TINNED COPPER GROUND BAR, 1 /4"x4"x10", NEWTON INSTRUMENT CO. CAT. NO. B-6142 OR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. 2- INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061-4 1. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING LOCK WASHERS, COAT ALL SURFACES WITHI 3- 5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. ANTI -OXIDANT COMPOUND BEFORE MATING. CAT. NO. 3015-8 2. ALL HARDWARE SHALL BE S/S 3/8" 0 OR LARGERI 4- WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-5056 3. FOR GROUND BOND TO STEEL ONLY: INSERT A DRAGON TOOTH WASHER BETWEEN LUG AND STEEL, 'j/ u ,. u u �.x COAT ALL SURFACES WITH ANTI -OXIDANT COMPOUND BEFORE MATING. 5- 5/8-1 1 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. -TYP OF (2). (1) FOR TOWER GROUND CAT NO. 3012-1 (1) FOR ELECTRICAL SERVICE TYPICAL ANTENNA GROUNDING 3 I TWO LUG GROUND 21 GROUND BAR 1 at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlinl.. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 NrR'15_rnUETUPF SERVICE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL07070F_R02 SITE NAME CRAN_RUTH_ARVDA SEAL O�PQ� REG/s F ,T 59Fo EXP 0�F.10/31/2021; ���`` 0'9/0 NM_ SIGNED, 3 JUN 2021 U m o > LO cn � w !wz0N z00 zw O W W U =):2 Q M wa- :2 _j=) Q :2 O � U O z V) 0 O U 0 V) w � p w U ~ � U cv o�=)5 x m a Q U 0 0 a- 0 w Y U w r U m� rn rn rn rn J N On Q N N O O Lo z x 0 0 0 0 0 LLW 0 W O — N n� o � SHEET TITLE GROUNDING DETAILS SHEET NUMBER G-1 GENERAL NOTES: 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR - SMARTLINK, LLC SUBCONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) OWNER - AT&T MOBILITY OEM - ORIGINAL EQUIPMENT MANUFACTURE 2. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CONTRACTOR. 3. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 4. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 5. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 6. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONTRACTOR. 7. SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. SUBCONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE CONTRACTOR. ROUTING OF TRENCHING SHALL BE APPROVED BY CONTRACTOR. 8. THE SUBCONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT SUBCONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 9. SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OFF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 10. SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 11. ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 301. 12. ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS UNLESS OTHERWISE SPECIFIED. ALL CONCRETING WORK SHALL BE DONE IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS. 13. ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS. 14. CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 25741-000-3APS-AOOZ-00002, "GENERAL CONSTRUCTION SERVICES. 15. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. GENERAL NOTES ELECTRICAL INSTALLATION NOTES: 1. 1. WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC AND TELCORDIA. 2. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC AND TELCORDIA. 3. EACH END OF EVERY POWER, GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH EXISTING INSTALLATION REQUIREMENTS. 4. POWER PHASE CONDUCTORS (I.E., HOTS) SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 16 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). PHASE CONDUCTOR COLOR CODES SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION REQUIREMENTS. 5. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PLANELOAD AND CIRCUIT ID'S). 6. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. 7. ALL TIE WRAPS WHERE PERMITTED SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP USE LOW PROFILES TIE WRAPS. 8. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (12 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 9. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS OTHERWISE SPECIFIED. 10. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (12 AWG OR 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED. 11. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRENUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75°C (90°C IF AVAILABLE). 12. RACEWAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 13. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. 14. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 15. GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE. 16. RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC. 17. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 18. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SETSCREW FITTINGS ARE NOT ACCEPTABLE. 19. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 20. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE. 21. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. 22. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 3R (OR BETTER) OUTDOORS. 23. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED, OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 24. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 25. THE SUBCONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CONTRACTOR BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 26. THE SUBCONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY. GROUNDING NOTES: 1. THE SUBCONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ), THE SITE-SPECIFIC (UL, LPI, OR NEPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND TIA GROUNDING STANDARDS. THE SUBCONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE CONTRACTOR FOR RESOLUTION. 2. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 3. THE SUBCONTRACTOR SHALL PERFORM IEEE FALL -OF -POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1 100 AND 81) FOR NEW GROUND ELECTRODE SYSTEMS. THE SUBCONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. TESTS SHALL BE PERFORMED IN ACCORDANCE WITH 25471-000-3PS-EG00-0001, DESIGN & TESTING OF FACILITY GROUNDING FOR CELL SITES. 4. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 5. EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS; 2 AWG STRANDED COPPER FOR OUTDOOR BTS. 6. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 7. APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 8. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 9. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 10. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 11. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 12. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION REQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE CONDITIONS. 13. ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESS OTHERWISE NOTED. 14. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE, ABOVE GRADE CONNECTIONS: EXOTHERMIC WELD TYPE. 15. GROUND RING SHALL BE LOCATED A MINIMUM OF 30" BELOW GRADE OR 6" MINIMUM BELOW THE FROST LINE, WHICH EVER IS DEEPER. 16. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM EQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE. 17. ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICAL CONTRACTOR. 18. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING. 19. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM). at&t Mobility AT&T MOBILITY 161 INVERNESS DR WEST, 2ND FLOOR ENGLEWOOD, CO 80112 smartlini.. 8502 E VIA DE VENTURA, SUITE 220 SCOTTSDALE, AZ 85258 r � `tee a 1 0- INF`R lt5Tnu ETLJK2E ERIAI CE 3450 N HIGLEY RD. SUITE 102. MESA, AZ 85215 ADDRESS 9990.5 W 51 ST PLACE WHEAT RIDGE, CO 80002 SITE NUMBER COL0707OF_RO2 SITE NAME CRAN_RUTH_ARVDA SEAL O�PQ� REG/s F ,T 459Fo EXP :� 0�F.10/31/2021; Ss/O NM_ SIGNED, 3 JUN 2021 U m �cn > LO w w � w ! cm z o 0 0- Z O W G_ U 0 Z w � Q M a-: J e w � Q :2 o � U C) z 0 0 U 0 m � p w U ~ 0 U Nw o�=)5 x m a Q U O U a- 0 o w Y U w r U 00 00 O O) O O J N On m Q O \ N \ N \ O O N Lo Z O O O O O LL LL w O W O N 0 tYl SHEET TITLE GENERAL NOTES SHEET NUMBER GN -1 Small Cell Location &Justification Section 26-615.H of the City Code permits small cell facilities in the right-of-way in under the following priority, ranked 1-5. Check the item that applies to your proposed facility. ❑ 1. City -owned utility pole (removed and replaced with new pole, conveyed back to City) ❑ 2. City -owned utility pole (attached to existing pole) El 3. Third -party owned utility pole with owner's permission (attached to existing pole) ❑ 4. Traffic signal pole or mast arm (requires City or CDOT approval) ❑ 5. New freestanding or ground -mounted facility Explain the reason for choosing the type of facility, and why other higher -priority locations were not selected, if applicable (required): AT&T and Xcel Energy have entered into a license agreement to Collocate on existing Xcel Energy poles/assets to minimize visual impact and ground disturbance across all state and local jurisdictions, nationwide. We do not have a list of City of Wheat Ridge -owned -poles, so we cannot target priorities 1 and 2. Furthermore, we have vetted many locations with all departments and CBO Randy Slusser, prior to the City's new Small Cell Guidelines (this is one of the locations). We are in good faith, going through the new small cell process and guidelines with each previously approved site, to help illustrate our partnership with the City. Please contact the AT&T and Xcel Energy Authorized Representative and Applicant, Brian Hess, at 720.244.5184, or Brian. Hess@SmartlinkGroup.com, with any questions or concerns. j9 Xcel Energy RESPONSIBLE BY NATURE' June 10th, 2020 City of Wheat Ridge 7500 W 29th Ave Wheat Ridge, CO 80033 RE: Letter of Authorization To Whom It May Concern: 825 Rice Street Saint Paul, Minnesota 55117-5485 This letter is to confirm that New Cingular Wireless PCS, LLC ("Licensee") has entered in to a Pole License Agreement with Public Service Company of Colorado d/b/a Xcel Energy which allows for the attachment of wireless communications equipment to Xcel Energy owned street light poles in Colorado. This letter constitutes a general acceptance for Licensee to proceed with requesting to collocate on the Xcel Energy owned street light poles at the locations detailed in the attached document. Final approval by Xcel Energy for each location is subject to a formal review and approval process per the terms and conditions of the Pole License Agreement. If you have any questions or concerns please feel free to contact me. Sincerely, Chelsey Fayerweather Xcel Energy Facilities Attachment Specialist, Small Cell 825 Rice Street, 3rd Floor St. Paul, MN 55117 Office: (651) 229-5560 Chelsey.Fayerweather@xcelenergy.com July 28th, 2020 State of Colorado All Local Jurisdictions RE; Blanket Designated Agent Letter of Authorization To Whom It May Concern: AT&T Mobility Services LLC 161 Inverness Drive West Englewood, CO 80112 The Smartlink Group and its employees and agents, specifically Brian Hess, Brian Gray and Mackenzie Hunt, are authorized representatives of AT&T Mobility and have been contracted to perform certain Right -of -Way Permitting, Land -Use Entitlements, Building Permits, Real Estate Leasing, Environmental, Architectural and Engineering Services on the AT&T Mobility Telecommunications Project. As an authorized representative of AT&T Mobility, the Smartlink Group, may sign, file, review land -use applications and permits, represent at hearings, and accept conditions of approval on behalf of AT&T Mobility. If there are any questions or comments, please contact me directly. Sincerely, _d'AKtt_'*, Veronica Bonilla Tech Vendor Management Site Acquisition Project Manager AT&T Mobility — Rocky Mountain Region Email: vb1319@att.com From: no-nanlv(alci.wheatridae.co. us To: CommDev Pets Subject: Online Form Submittal: Small Cell Permit Application Date: Wednesday, May 19, 20214:29:40 PM Small Cell Permit Application YOU MUST ATTACH AN ELECTRONIC PAYMENT FORM IN ORDER FOR THE PERMIT TO BE PROCESSED THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. LOCATION ELIGIBILITY: I attest that the proposed location has been approved by the Planning Division and the address I will provide on this form is the address provided to me by the Planning Division. RIGHT-OF-WAY PERMIT: I attest that the proposed location is in City of Wheat Ridge right-of-way and understand I must also obtain a separate Right -of -Way Permit from the Engineering Division to be authorized to construct the small cell facility in City right-of-way. Yes Yes LOCATION INFORMATION Location Address 9990.5 W 51st PI Location Coordinates Attach City of Wheat Ridge Electronic Payment Form "DO NOT ATTACH A 39.790137. -105.109043 PICTURE OF A CREDIT CARD" CONTACT INFORMATION Submitting General Overland Contracting Inc ("OCI") Contractor or Electrician Contractor's License 00000 Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contact Phone Number 303-810-5827 (enter with dashes, eg: 303-123-4567) Contact Email Address farleyt@overlandcontracting.com for questions or comments Retype Contact Email farleyt@overlandcontracting.com Address DESCRIPTION OF Install new 30' AT&T Standalone small cell pole with RF WORK Equipment mounted at various elevations. Project Value (contract 20,000 Valuation OK value or cost of ALL materials and labor) Upload completed Small Cell Location Justification COL0707OF R02_9990 5 W Small Cell Location & 51stAve Ddf Justification form. Upload Drawings 11 ° X COL0707OF R02 REV 3 FCD 06 04 19 (Approved TA 4 Jun 17" or larger including 2019).odf elevations, site plan, and electril plans Upload owner Xcel Eneray and ATT Letters of Authorization City of Wheat permission of Ridae Ddf colleocating on or modifying an existing pole. SIGNATURE OF Yes UNDERSTANDING AND AGREEMENT I understand that work Yes may not begin at this location until this permit and a Right -of -Way Permit has been issued I understand that work Yes may not begin until a Small Cell Master License Agreement has been executed with the Department of Public Works (One agreement is required per telecom) I attest that everything YES state in this application is true and correct and that falsifying information in this applicaton is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Brian Hess (Authorized Rep for Xcel Energy +AT&T) Permit Email not displaying correctly? View it in your browser. � ► 44" City of Wheat Ridge '/� COMMERCIAL SMALL CELL PERMIT - 202101063 PERMIT NO: 202101063 ISSUED: 06/24/2021 JOB ADDRESS: 9990.5 W 51st Pl EXPIRES: 06/24/2022 JOB DESCRIPTION: Install new 30' AT&T Standalone small cell pole with RF Equipment mounted at various elevations. *** CONTACTS *** OWNER (303)234-5900 MESA VERDE PARTNERSHIP, LLP *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 105 / BLOCK/LOT#: / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 20,000.00 FEES Total Valuation 0.00 Plan Review Fee 235.82 Use Tax 420.00 Permit Fee 362.80 ** TOTAL ** 11018.62 *** COMMENTS *** *** CONDITIONS *** Pole must be painted black. I, by my signature, do hereby attest that the work to, be performed shall comply with all accompanying approved plans and specifications, applicae building codes, and all applicable municpal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this�permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/24/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: r Job Address: g;;- 197— Permit 7Permit Number: I' C6 a ❑ No one available for inspection: Tin Re -Inspection required: Yes `No,� M When corrections have been made, scheiduTip for re -inspection online at. http✓/www.ci. wheatridge.co.usdnspection _ Dat :- �-Iped`O_r_: g.. n.-- City of _/' W heat dge COMMUNiTy DEVELOPMENT Building & Inspection Services 7500 W. 2911 Ave., Wheat Ridge, CO 80033 Office: 303-235-2855 * Fax: 303-237-8929 Inspection Line: 303-234-5933 Email: oermitsCcci.whackidae.co.us Property Address: Prooertir FOR OFFICE USE ONLY Date: Plan/Permit # ,,AON J 6 Plan Review Fee�� Buildy Permit Application ipplicabghlighted areas on both sides of this form. plete aptions may not be processed. *** W 51st Placa(Arvada CO 80002 City/f Wheat Prop y Ow Email: /A Tenant N e (Commercial P jects Property Owne ling dress: (if Address: 7500 W 29t e • Public Riaht-of-W Only) AT&T (New Cingular Wireless' City, State, Zip: Whe?/Ridge&C?400331� address) !! 303-234-5900 Architect/ cant is Brian Hess with Smartlink, LLC, authorized by and submitted on behalf of AT&T Architect/En e��lail: Brian. Hess@Smartlinkllc.com Phone: 720-244-5184 Contract Name: TBD City Olt heat Ridge License #: Contractor E-mail Address: Phone: For Plan Review Questions & Comments (please print): CONTACT NAME (please print): Brian Hess Phone: 720-244-5184 CONTACT EMAIL(p/ease print): Brian.Hess@Smartlinkllc.com Sub Contractors (Must provide Wheat Ridge License No & Signed Subcontractor Authorization form): Electrical: Plumbing: Mechanical: W.R. City License # W.R. City License # W.R. City License # Other City Licensed Sub: Other City Licensed Sub: City License # City License # Complete all highlighted fields. COMMERCIAL ❑ RESIDENTIAL Provide description of work: For ALL projects, provide a detailed description of work to be performed, including current use of areas, proposed uses, square footage, existing condition and proposed new condition, appliance size and efficiency, type and amount of materials to be used, etc. AT&T (New Cingular Wireless) proposes a new small cwireless facility installation on a new stealth utility pole. The scope of work will consist of Installing (1) new 30' pole, (1) na mo (3) remote radio head un' inside enclosure, (1) meter socket, (1) load center at each location.�� NNS Sq. Ft./LF N/A BTUs Gallons Amps Squares For $Olar: Kw # of Panels Requires Structural For Commercial Projects: Occupancy Type: Construction Type: �'� �_ Occupancy Load: Square Footage: Project Value: (Contr lueJpr thelost of all materials and labor included in the entire project) $ 20,000 \ / ON'NEER�TPV%kCTOR SIGNURE OF UNDERSTANDING AND AGREEMENT I here cei that th etback di races proposed by this permit application are accurate and do not violate applicable ordinances, rules or regulatio oftty o heat dge or covenants. easements or restrictions of record: that all measurements shown and allegations made are accurate: th have and a e to abide by all conditions printed on this application and that I assume full responsibility for compliance with applicable of Wheat idg , codes and ordinances for work under any permit issued based on this application; that'l am the legal owner or have been autho by t legal owner of the property to perform the described work and am also authorized by the legal owner of any entityrrwi�wi�.uwfiriya pli tion to list that entity, on this application. I, the applicant for this building permit application, warrant the truthfulness of the in—forma n provided on the ap ication. CIRCLE ONE: () (CONT CTOR) r UTHORIZED REPRESENTATIVE of OWNER (CONTRACTOR) Signature (first and): DATE: 12/26/2018 Printed Name: Hess DEPARTMENT USE ONLY ZONING COMMMENTS: Reviewer: BUILDING DEPARTMENT COMMEN S: ewer: �^ PUBLIC WORKS COMMENTS:: Reviewer SOW T4,tv+nt-�' OCCUPANCY CLASSIFICATION: (Alf CONSTRUCTION TYPE:, 44 Building Division Valuation: 2) f C City of Wheat Ridge Community Development Department Memorandum TO: Accounting Department FROM: Kim Cook, Building Division SUBJECT: Refund for Permit DATE: January 17. 2019 Reason: Permit cancelled, plan review fee needs to be refunded for 201803318. Please refund: Contractors License$ (acct 01-510-00-513) 80% permit fee: $ (acct 01-510-00-516) 100% plan review $235.82 (acct 01-550-05-551) 100% use tax: $ (acct 01-500-02-505) Total Refund Due: $235.82 TO: Smartlink, LLC 1997 Annapolis Exchange Parkway Suite 200 Annapolis, MD 21401 Thank You! KI� C004 Permit Technician MY),/ 4 I ct)MML1N1 CY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29`h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Refund Application Complete this application in its entirety, attach all copies of permits, permit cards (if issued) and receipts that were received at the time of permit issuance. Requests for more than 80 percent of the amount paid will not be approved without prior approval from the Building Official. The refund application must be received by the Wheat Ridge Building Division no later than 180 days after permit issuance. Applications received after 180 days of permit issuance will not be approved. You can mail or hand -deliver all required documents to: City of Wheat Ridge, Attn: Building Division, 7500 W. 29h Ave., Wheat Ridge, CO 80033. Company Name/Name (to whom check should be made out to): Smartlink, LLC Address: 1997 Annapolis Exchange City: Annapolis Phone: 888.828.5465 pax: go 903315� , Suite 200 State: MD Zip: 21401 Email: brian.hess@smartlinkllc.com Permit #: none issued yet Permit Address: 9990.5 West 51st Place Reason for request: no building perm it required. ROW permit only. Printed Name: Brian Hess For office use only This request has been: ❑ Approved Approved by - Signature. 0 Denied www.ci.wheatridge.co.us Date: Date: 1/16/2019 Refund Amount: $ City of Wheat idge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P:303.235.2846 F:303.235.2857 December 31, 2018 OFFICIAL ADDRESS NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: 9990.5 West 51" Place AUTHORIZED BY: DISTRIBUTION: 1. Property Owner 2. brian.hess@smartlinkllc.com 3. Xcel Energy, sandra.cardenas(a)xcelenergy.com 4. Wheat Ridge Building Division 5. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.d.wheatridge.co.us DATE: li'411le DATE: Vicinity Map Rik City of Wheat AiCe COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P:303.235.2846 F:303.235.2857 December 31, 2018 OFFICIAL ADDRESS NOTIFICATION NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: 9990.5 West 51S` Place NOTES: AUTHORIZED BY 17kill-111VI-31 #-W-0 1. Property Owner 2. brian.hess@smartlinkllc.com 3. Xcel Energy, sandra.cardenas(a-)xcelenergy.com 4. Wheat Ridge Building Division 5. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.ci.w h eatridge.co. u s DATE: IL DATE: