Loading...
HomeMy WebLinkAbout4074 Clear Creek DriveFebruary 9, 2021 Evergreen Development 1873 South Bellaire Street, Suite 1200 Denver, CO 80222 Attn: Evergreen Development Re: Compliance Letter for Special Inspections Outlook Clear Creek, Permit No.: 201902585 4074 Clear Creek Drive,, Garage A Wheat Ridge, CO CG Project Noe. 19.23.225 Cole Garner f-AmAt technical 1070 W. 124 t" Ave, Ste. 300 Westminster, C 111111111111) 802 34 303.996.2999 At your request,, Cole Garner Geotechnical (CGG) was retained to provide construction special inspection and materials testing for the above-named project. Observation and special inspection services were performed as scheduled by the contractor during the construction of the following elements: Fairestoppoing - periodic visual special inspection of membrane penetrations to verify adherence with manufacturer recommendations for UL rating Wood Framing -visual inspection of shear and gravity systems including member size, grade and orientation including hardware and fasteners The results of our special inspections were noted to comply with the approved project plans, specifications and relevant sections of the International Building Code. We trust that the information presented herein satisfies your present needs. Sincerely, irner Geotechnical Thomas C. Cole, P.E. Principal PF Q�p,DO L ICE �ARIS w ;0 42518�s 041" a -09 ,Y o2/09/21 IONAkco CCN _M� Cole Garner f-AmAq technical 1070 W. 124 t" Ave, Ste. 300 Westminster, C 111111111111) 802 34 July 21, 2020 Evergreen Development 1873 South Bellaire Street, Suite 1200 Denver, CO 80222 Attn: Evergreen Development Re: Compliance Letter for Special Inspection and Materials Tests Outlook Clear Creek, Permit No.: 201902585 4074 Clear Creek Drive,, Garage A Wheat Ridge, CO CG Project Noe. 19.23.225 303.996.2999 At your request,, Cole Garner Geotechnical (CGG) was retained to provide construction observations and materials testing for the above-named project. Observation and special inspection services were performed as scheduled by the contractor during the construction of the following elements: Excavation Observation -observation prior to foundation construction to verify conformance to with geotechnical report Reinforced Concrete -inspection of reinforcing steel and concrete placement for foundations and slabs Concrete Encased Grounding Rod - inspection of placement of Ufer ground rod in foundation Post -Tensioned Concrete - inspection of tendon layout,, concrete placement operations and subsequent stressing operations In addition, materials tests were periodically conducted for the following elements: Concrete - temperature, slump, air content,, unit weight and compressive strength; The results of our materials tests and special inspections were noted to comply with the approved project plans, specifications and relevant sections of the International Building Code. We trust that the information presented herein satisfies your present needs. Sincerely, arner Geotechnical Thomas C. Cole, P.E. Princi pal DO �Y1RlSp°°� S Ci ond o 42518 �: s °•. 7�0 Q rz 21 20 o��sS�ONAL EN�\� _M� The City of Wheat Ridge 7500 W. 29th Avenue, Wheat Ridge, CO 80033 Property Address Permit Number Permit Issued Date Owner Information Property Owner Information Property Owner Address Inspection Company Inspector Name Inspector Contact info. Third Party Form Check List 4074 Clear Crk Dr 201902585 L,t 14 Inspector Statement and Acknowledgement * I hearby acknowledge the roof I am inspecting is 6/12 or over. All roofs that are under 6/12 must be inspected by the City of Wheat Ridge Buiding Dept. * I hearby acknowledge the roofing system for the referenced building has been inspected and found to be in compliance with the minimum requirements of the 2012 IRC and 2012 IBC as well as all City of Wheat Ridge Policies and Procedure and Manufacturer's (3c".0 recommendatind specifications. ns Inspector: Date: f/ Z/2 % Property Owner Statement of Acknowledgement *1 hearby acknowledge that I am the owner of the building referenced above and I give my consent for the listed third -party inspection company to perform my roof inspection in lieu of the City of Wheat Ridge Building Division inspection. Propery Owner/Agent: Date: This original document must be submitted to the Chief Building Official within seven days of the final inspection. Email to permits@ci.wheatridge.co.us Please add note to reverse side The City of Wheat Ridge Inspection Check List notes Mid -Roof PROPERTY ADDRESS 4C)-7 p(J 11C Roof Inspection ❑ N/A ❑ Pass ❑ Fail �N/A ❑ Pass ❑ Fail Structural roof components ❑ N/A ® Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Q Pass ❑ Fail Flashing for roof and walls [C -Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ❑ N/A ❑ Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A ® Pass ❑ Fail Crickets and saddles where needed N/A ❑ Pass ❑ Fail Verify B vent must have boot same gauge as pipe R] N/A ❑ Pass ❑ Fail Verify vent caps 0 N/A ❑ Pass ❑ Fail Verify no flashings are damaged or rusted ® N/A ❑ Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle 2] N/A ❑ Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/A ® Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A 14 Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC ❑ N/A Q Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A [] Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A ( Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope: Exception, detached garages, patios, carports, open on three sides with min. slope of 1:12 Q N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope N/A ❑ Pass ❑ Fail Above roof insulation R-25 K N/A ❑ Pass ❑ Fail Below roof residential R-38 [5� N/A ❑ Pass ❑ Fail Below roof commercial R-32 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturers specifications- Must have manufactures letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 rk N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Mid -Roof Notes Company Name: ° L ,,.; v ONE - Inspector signature: Date of Inspection: The City of Wheat Ridge Inspection Check List notes Final Roof PROPERTY ADDRESS: qd?% c Le px CwEr, or�_(t, Roof Inspection ❑ N/A ❑ Pass ❑ Fail [A N/A ❑ Pass ❑ Fail Structural roof components Q N/A ❑ Pass ❑ Fail Verify that no more than 2 layers of shingles exist ❑ N/A Pass ❑ Fail Flashing for roof and walls Pass ❑ Fail If new sheathing is installed verify that it is listed in the permit description (Valuation must be adjusted) ] N/A ❑ Pass ❑ Fail Verify sheathing nail pattern (See Policy & Procedures) ❑ N/A [9� Pass ❑ Fail Crickets and saddles where needed ® N/A ❑ Pass ❑ Fail Verify B vent must have boot same gauge as pipe ❑ N/A ® Pass ❑ Fail Verify vent caps ❑ N/A ® Pass ❑ Fail Verify no flashings are damaged or rusted ❑ N/A lj� Pass ❑ Fail Step flashing shall be min. of 4x4 piece per shingle ❑ N/A 1� Pass ❑ Fail Verify scuppers allow for proper drainage ❑ N/Ai[(j Pass ❑ Fail Ice and water shield 2' in heated wall spaces ❑ N/A [ Pass ❑ Fail Underlayments must follow 2012 IRC / 2012 IBC F1 N/A [ Pass ❑ Fail Verify roof slope for proper drainage ❑ N/A Sj Pass ❑ Fail Dripedge shall have min of 2" overlap ❑ N/A Pass ❑ Fail Dripedge should extend down min 2" past roof deck ❑ N/A N Pass ❑ Fail Dripedge shall be mechanicaly fastened 12" OC N/A ❑ Pass ❑ Fail 90 LB roll roofing shall not be applied to roof slopes less than 2:12 slope; Exception: detached garages, patios, carports, open on three sides with min. slope of 1:12 N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope ® N/A ❑ Pass ❑ Fail Above roof insulation R-25 N/A ❑ Pass ❑ Fail Below roof residential R-38 [] N/A ❑ Pass ❑ Fail Below roof commercial R-32 Q N/A ❑ Pass ❑ Fail Modified Bitumen, EPDM, TPO min slope 1/4:12 slope must be installed in accordance with the manufacturer's specifications - Must have manufacturer's letter of warranty with the address on the letter for final inspection Metal Roof Shingles Requirements (] N/A ❑ Pass ❑ Fail Metal roof shingles shall not be installed on slope less 3:12 ® N/A ❑ Pass ❑ Fail Metal valley flashing shall be the same material as roof ® N/A ❑ Pass ❑ Fail Metal valley flashing shall extend a min of 8" from the centerline with a min. of 3/4 " high splash diverter rib built-in at the flow line with sections overlapping a a min. of 4" Tile Roofs Requirements R N/A ❑ Pass ❑ Fail Clay and concrete tile shall have a min. 2-1/2:12 slope Slopes 4:12 and under require double underlayment The City of Wheat Ridge Inspection Check List notes Final Roof Notes Company Name: ko"iwwcti' IF e�� Inspector signature: y Date of Inspection: i gz- o/gj buildina ONE consultina. Ilc April 12, 2021 Mr. Tom Harris Evergreen 1873 South Bellaire Street, Suite 1200, Denver, CO 80222 RE: Building Envelope Consulting Services Outlook Clear Creek W heatridge, Colorado Project Number 19 -1205 -CC Dear Mr. Harris: 4074 Clear Creek Drive 201902585 Building One reviewed the Building Envelope at the Outlook Clear Creek property, specifically at the 4074 Clear Creek Drive address. The weather resistive barrier was observed at all exterior wall assemblies. Building One initially noted some inconsistencies, but it appears that all our concerns have been addressed It is our understanding that the exterior wall assemblies are in general conformance with the construction documents and industry standards. If you have any questions, please do not hesitate to call. Sincerely, Building One Consulting, LLC Chad Stinnett, RA Associate ViaEmail. Tom Harris'. tharrisadevme.com denver I boston 3190 s. wadsworth blvd., suite 230 1 lakewood, co 80227 1 303.986.1400 ®, ®_ CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: VV Job Address: '-10 7t-1 Clear r" Z)O-- I Permit Number: i ?Q/ry cQ Z- 57 { I I i I I I ❑ No one available for inspection: Time AM/PM) { 1 Re -Inspection required: Yes No j When corrections are complete, schedule re -inspection online. Date:_3 ' I — Z Inspector: i DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE -QV, Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE inspection Type: Job Address: Permit Number: j ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes '`No When corrections are complete, schedule re -inspection online. Date: - Inspector: 5, DO NOT REMOVE THIS NOTICE 44" City of Wheat Ridge _A� Commercial Accessory Structure PERMIT - 201902585 PERMIT NO: 201902585 ISSUED: 02/19/2020 JOB ADDRESS: 4074 Clear Creek Dr EXPIRES: 08/20/2021 JOB DESCRIPTION: Clear Creek Crossing - Single story, 16 bay detached garage - 1,898 sq ft total *** CONTACTS *** OWNER EVERGREEN CLEAR CREEK CROSSING GC (303)757-0401 Ron Wolford 180393 Nexus Builders LLC SUB (303)795-6116 MONTE LOSAW 160078 LOSAW ELECTRIC INC. SUB (303)288-2308 WILLIUAM C COFFEY III 110081 PLATTE RIVER PLUMBING INC. SUB (720)373-4378 CORY JOHNSTON 190344 CBA MECHANICAL *** PARCEL INFO *** ZONE CODE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned *** FEE SUMMARY *** Total Valuation Plan Review Fee Use Tax Permit Fee Engin. Review Fee Misc. Fee ** TOTAL ** *** COMMENTS *** USE: UA / Unassigned BLOCK/LOT#: / ESTIMATED PROJECT VALUATION: FEES 0.00 120.00 11530.54 914.70 100.00 240.00 2,905.24 72,883.00 *** CONDITIONS *** Approved per plans and red -line notes on plans. Must comply with 2012 IBC, 2017 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. **Prior to final inspection approval - As-builts are required before approval of the Building Final Inspection and Certificate of Occupancy can be issued. No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. All landscaping shall be installed in accordance with the approved landscape plan (Case No. WZ-19-01) prior to C.O. and pursuant to the phasing identified in the Subdivision Improvement Agreement. Per the SIA, installation of landscaping, street trees, and irrigation is not required prior to Certificate of Occupancy if issuance of the C.O. occurs outside of the planting season, generally October to June. Architectural elevations shall match the approved master plan permit. 1* � 4 41' PERMIT NO: JOB ADDRESS: JOB DESCRIPTION: City of Wheat Ridge Commercial Accessory Structure PERMIT - 201902585 201902585 ISSUED: 02/19/2020 4074 Clear Creek Dr EXPIRES: 08/20/2021 Clear Creek Crossing - Single story, 16 bay detached garage - total 1,898 sq ft I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This.permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 02/19/2020 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. ♦� City of Wheatldge COMMUNITY DEVELOPMENT CityofWheat Ridge Municipal Building 7500 W. 20 Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2855 F: 303.237.8929 Permit Extension Request Form Permits expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180 days may be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. Please complete this form in its entirety and submit to the Building Division at permits(cilci.wheahidge.co.us or fax to 303-237-8929. Party requesting permit extension: Evergreen Clear Creek Crossing Permit # 201902585 Property Address: 4074 Clear Creek Dr. Phone# 720-272-8725 Email Address: adeckert@evgre.com Reason for extension request: Delayed construction start Number of days requested: 4/30/2021 Printed Name: Amy Deckert Signature:_z"—' Date: 02/22/2021 For office use only This request has been: XApproved ❑ Denied Extended =it 8/20/2021 Approved by: 7 i'k 2 Z;' Daze: 2/22/2021 www.ci.whealridgaco.us CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -inspection required: Yes No When corrections are complete, schedule re -inspection online. Date:_'T - Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: , C-kFAP{` Permit Number: ❑ No one available for inspection: m - AM/PM Re -Inspection required: Yes`LNgs When corrections have been made, �h c n bnUmeat: http;//www.ci.wheatridge.co,uslinspe,tio '' 1- 1 IN Daor, i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE r Inspection Type: Job Address /1 Permit Number: ❑ No one available for inspection: Tiy AM/PM Re -Inspection required: Ys �~No When corrections have been made, schedt'le for re -inspection online at: i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. cL wheatridge, co, uslinspection Date: Inspector: DO NOT REMOVE THIS NOTICE Clear Creek Crossing Garage A 4074 Clear Creek Drive Permit No. 201902585 Cole Garner Geotechnical 1070 West 124th Ave Suite 300 Westminister, CO 80234 Phone: 303.996.2999 Activity Date: 03/26/2020 Technician: Todd Womersley Work Completed Type: Open Hole Location Details: Garage A (type B) Grade Beam subgrade Discrepancy: No Report of Inspection or Observation Client: Project: 4074 Clear Creek Dr. 201902585 Evergreen Development 19.23.225 1873 S. Bellaire, Suite 1200 Outlook Clear Creek Denver, CO 80222 4040 Clear Creek Drive Wheat Ridge, CO 80215 Details Weather: Partly cloudy Temperature (°F): 46 Field Notes: A firm and stable subgrade was observed. The grade beam subgrade is suitable for concrete placement. Reported to: Jacob Contractor: GBC Concrete Page 1 of 1 Cole Garner Geotechnical 1070 West 124th Ave Suite 300 Westminister, CO 80234 Phone: 303.996.2999 ReinforcedMoncrete Client: Evergreen Development 1873 S. Bellaire, Suite 1200 Denver, CO 80222 Activity Date: 03/09/2020 Activity Number: 7 Technician: Todd Womersley City OF. Wheat Ridge Weather: Clear Temperature (°F): 45 Environmental Placement Conditions: Cold Weather Provisions Work Completed Scope of Inspection: Reinforcing Only Location Details: Garage A Grade Beams Frequency: Asynchronous Level/Floor: 1 Plans & Details Referenced: S1-1.0, SG -1.0, and S3-0.0:1, 3, 4, 5, 6, 9, 10, and 12 Tendon Placement/Size/Grade: No Anchor Bolts/Holdowns, No Consolidation Adequate: No 4074 Clear Creek Dr. 201902585 Project: 19.23.225 Outlook Clear Creek 4040 Clear Creek Drive Wheat Ridge, CO 80215 Approved Mix Design Verified: No Deformed Bar Placement/Size/Grade: No Form Condition/Cover/Clearance: Yes Penetrations: Acceptable Field Notes: Garage Walls need to have 2 bars Top and Bottom for the entire length of the wall. Inspection Results Communicated To: Jacob w/ GBC Concrete Page 1 of 2 Image Description Image Date Taken Photogral Garage Walls 03/09/2020 Todd Wor Page 1 of 2 Gpot��t< Cole Garner Geotechnical 1070 West 124th Ave Suite 300 Westminister, CO 80234 Phone: 303.996.2999 ReinforcedMoncrete 4074 Clear Creek Dr. 201902585 Client: Project: Evergreen Development 1873 S. Bellaire, Suite 1200 Denver, CO 80222 19.23.225 Outlook Clear Creek 4040 Clear Creek Drive Wheat Ridge, CO 80215 Discrepancy: Yes Discrepancy Number: 2 Discrepancy Description: Garage Walls need to have 2 bars Top and Bottom for the entire length of the wall. Status: Open Page 2 of 2 ReinforcedMoncrete 4074 Clear Creek Dr. 201902585 Geotech Cole Garner Geotechnical 1070 West 124th Ave Suite 300 Westminister, CO 80234 Phone: 303.996.2999 Client: Evergreen Development 1873 S. Bellaire, Suite 1200 Denver, CO 80222 Activity Date: 03/26/2020 Activity Number: 18 Technician: Todd Womersley City OF. Wheat Ridge Weather: Partly cloudy Temperature (°F): 48 Environmental Placement Conditions: Cold Weather Provisions Work Completed Scope of Inspection. Reinforcing and Concrete Placement Location Details: Garage A (type B) Grade Beams Frequency: Asynchronous Level/Floor: 1 Plans $ Details Referenced: SO -0.2, SG1-1.1, SG1-2.0 Concrete/Shotcrete/Gunite: Concrete Tendon- Placement/Size/Grade: No Anchor Bolts/Holdowns: No Method of Deposition: Pump Project: 19.23.225 Outlook Clear Creek 4040 Clear Creek Drive Wheat Ridge, CO 80215 Approved Mix Design Verified: Yes Deformed Bar Placement/Size/Grade: Yes Form Condition/Cover/Clearance: Yes Penetrations: Acceptable Consolidation Adequate: Yes Field Notes: Ufer located approximately 5' West of Southeast corner of building Inspection Results Communicated To: Jacob w/ GBC Concrete Discrepancy: No Page 1 of 1 Cole Garner Geotechnical 1.070 West 124th Ave Suite 300 Westminister, CO 80234 Phone: 303.996.2999 ReinforcedMoncrete 4074 Clear Creek Dr. 201902585 Client: Evergreen Development 1873 S. Bellaire, Suite 1200 Denver, CO 80222 Activity Date: 04/14/2020 Technician: Randy Cotton Weather: Sunny Environmental Placement Conditions: Normal Scope of Inspection: Reinforcing and Tendons Only Location Details: Garage A (16 car garage) Frequency: Continuous Lovel/Floor. 1 Plans-& Details Referenced: Structural drawings dated 11/15/19; PT4 Dated 11/15/19 Vertical Bars for CMU Conform with Masonry Plans: Not Applicable Anchor Bolts/Holdowns: Yes Consolidation Adequate: No Activity Number: 41 City Of: Wheat Ridge Temperature (°F): 70 Work Completed Inspection Results Communicated To: Dan with Evergreen Discrepancy: No Project: 19.23.225 - Outlook Clear Creek 4040 Clear Creek Drive Wheat Ridge, CO 80215 Approved Mix Design Verified: No Deformed Bar Placement/Size/Grade: Yes Tendon Placement/Size/Grade: Yes Form Condition/Cover/Clearance: Yes Penetrations: Acceptable Tendon Anchorage/Backer Bars/Stud Rails: Verified Page 1 of 1 4074 Clear Creek Dr. 201902585 ,ANCHOR ENGINEERING STRUCTURAL ENGINEERS July 7, 2020 Kephart Architects Attn: Janet Grady 2555 Walnut Street Denver, CO 80205 RE: Outlook Clear Creek Garage A, Re -Stress 4074 Clear Creek Drive Wheat Ridge, CO 80215 Dear Mrs. Grady, Per our contract, our office reviewed tendon elongation reports dated April 30, 2020 and May 8, 2020 provided by Cole Garner Geotechnical for the above referenced project. The reports indicate that the special inspector from Cole Garner observed as the tendons were stressed using the following equipment: Ram No. PT Jacks & Accessories 2018-020 (#210) Gauge No. McDaniel (#210), 10,000 PSI, 4" Pump No. SPX Power Team, S/N 376088 (#210) The equipment was last calibrated on April 15, 2020. The corresponding stressing gauge pressure is 5,440 pounds per square inch when applying 33 kips of tension to the tendon. A copy of the associated calibration curve was provided to our office for our records and review. Reports dated April 30, 2020 was for all of the tendons in the pour. After review of this report tendons #113, #2B, #3A, #3B, #4A, #4B, #5B, #6A, #6B, #7A, #8A, #8B, #9A, #9B, #11A, #11B, #13A, #13B, #14A, #14B, #15B, #16A, #16B, #28A, #29A, #30A & #35A did not meet the code allowed minus 10% deviation and needs to be re - stressed. Report dated May 8, 2020 was the elongation report for the tendons that needed to be re -stressed. Based on our review of the stressing records, calibration curve, PTI allowances of +/-1/4" elongations for short tendons, and the knowledge of the measurements taken to the nearest 1/8", it is our opinion that all the tendons included in these reports have been adequately stressed and can be burnt off to a distance of 3/4" inside the exterior surface of the concrete. Stressing pockets should be packed with grout as outlined in the contract documents. If you have any questions or need additional information, please contact our office. Sincerely, Anchor Engineering, Inc. r Charles D. Petzinger, P.E. Project Engineer ❖ 2535 17TH STREET, DENVER, CO 80211 303-783-4797 ❖ 303-830-9133 FAX ❖ 4' CITY OF WHEAT RIDGE V, _A Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: S,ex Cj Ll No one available for inspection: Time /<-­-, .. AM/PM Re -Inspection required: Yes "No. When corrections have been made, schedule for re -inspection online at: hffp:IAvww. ci. wheatridge. co. uslinspection Date:— Inspector: DO NOT REMOVE THIS NOTICE A i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE 424/ Inspection Type:/20( Job Address: �- �- Dee- Permit Number: ❑ No one available for inspection: Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at. http://www.ci. whea tridge. co. usfinspecto� Dates 2 spec Approval by: City of '� W heat Pidge COMMUNITY DEVELOPMENT FOR OFFICE USE ONLY 5/15/2020 61 [nspector Dat City of Wheat Ridge Municipal Building 7500 W. 29" Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIF For Commercial and Multi -Family Developments This form must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This form must be accompanied by a Construction Control Plan following the procedure found on the reverse side of this form. DATE: MAY 13, 2020 PERMIT# 201902585 ADDRESS: 4074 CLEAR CREEK DRIVE, WHEATRIDGE, CO LOT 1 , BLOCK 1 OUTLOOK AT CLEAR CREEK CROSSING SUBDIVISION SURVEYOR: I hereby certify that the elevations and distances shown on the attached sheets and as stated below for the recently formed or constructed structural foundation for the above property have been measured by me or directly under my supervision. See the attached Form Check and Sheets 13 of the Construction Control Plan. All measurements have been determined on the following location: (Check only one): Top of proposed foundation wall prior to placement of concrete X Top of foundation wall subsequent to placement of concrete The setback and elevation measurements are included on the attach Signed ProfessloneI so". Print AARON MURPHY Date 5-13-20 x�, x.c,.xheatriJge.ca.us Plan. Rev 1123, OUTLOOK CLEAR CREEK CROSSING FORM CHECK GENERAL NOTES: 1. THE LINEAR UNITS FOR THIS SURVEY ARE U.S. SURVEY FEET. _ 2. THE PURPOSE OF THIS FORM CHECK IS TO SHOW THE DELTAS BETWEEN ,� - 5458.35 THE AS MEASURED FORMS AND THE PROPOSED BUILDING LOCATION. 3. THIS EXHIBIT DOES NOT CONSTITUTE A TITLE SEARCH BY HARRIS KOCHER SMITH TO DETERMINE OWNERSHIP OR EASEMENTS OF RECORD. 4. THIS EXHIBIT DOES NOT REPRESENT A MONUMENTED LAND SURVEY. SPECIFIC NOTES: 1. THE FIELD WORK WAS COMPLETED ON APRIL 22, 2020. 2. BENCHMARK: BASIS OF ELEVATION BASED ON NGS CONTROL POINT "F 412", A STAINLESS STEEL ROAD AT THE INTERSECTION OF KIPLING STREET AND WEST 32ND AVENUE WITH A NAVD88 ELEVATION OF 5,562.74. "F 412" IS A FIRST ORDER, SECOND CLASS CONTROL POINT. 3. FORM CHECK ELEVATIONS ARE MEASURED TO TOP OF FORM UNLESS OTHERWISE NOTED. 5' FORM LEGEND XX.X'— DENOTES THE DISTANCE BETWEEN THE AS—MEASURED AND THE PROPOSED LOCATION XXXX.XX ELEVATION FORM CHECK AS—MEASURED LOCATION C O.XX CUT TO PROPOSED ELEVATION (INDICATES FORM IS HIGH) F O.XX FILL TO PROPOSED ELEVATION (INDICATES FORM IS LOW) 20 0 20 40 SCALE: 1'= 20' HARRIS KOCHER SMITH mw�a�oao� F 0.04 .. .. ISSJEOA2 M,3IDA WiNEti/: 19]Si WlE PMSIW CP`MEHiB EVERGREEN DEVCO, INC. OUTLOOK CLEAR CREEK CROSSING FORM CHECK GARAGE 1 .36 CHECK 14 MATCHLNE - SEE SHEET 8 rrv..uebNov. Cal betweya EM. MATCHLNE - SEE SHEET 17 HARRIS KOCHERAW Evergreen 1 --sell I SMITH o.wa.om.m se.wm.a mreame.ls OUTLOOK CLEAR CREEK CONSTRUCTION CONTROL PLAN KEVMAP u.ms wxrz I ws 1.111s.rs. rhe ss.st..lr a z. nest. sts. N 111 .1svvN tart I r.um...w sl[ l..v - wrxs.m<1mmrv. 1. el..ee� .moi S.a m:en...v... . .—n a.. , e Ills' cnsl 117 e-shsw.. wWleM — —1 wannc IGFs .c 1. Is, nLt....w . mx I.,wenn- �n..... wsc. � L..m r.e � p.. suis e 1,11 1111 wn 1.' VVtvil�.°:"w e'Ll sev1 1..11.1.1 vols rearm neE .. m vmn rs. .111HMa o:1 . `vro.`r1.' aK...e rlmao e. x. .ws w wx<1 nvawa..00• rr m ni a w. V8,62 lsslxswur i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: /67 X06 Job Address: C44 -W Permit Number: .cd� 0 ❑ No one available for inspection: Time A Re -Inspection required:Yes No When corrections have been made, schedule for re -inspection online at: http✓/www. ci. wheatridge. co. uslinspection Date: e Inspector: DO NOT REMOVE THIS NOTICE } i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: is�� Job Address: ��� 7-q Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: h ttp✓/www. ci, wheatridge, co. uslinspection Date: 4.' /3-- Inspector: A', 'a-' DO NOT REMOVE THIS NOTICE I* � 4 i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: /f,,U4 ct? A% Job Address: Permit Number: / 'el >3",�, ;.,., A7d-1-r �sa�". ✓?s..nP-tee / ```-� ❑ No one available for inspection: Time 4PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: http✓/www.ci. wheatridge.co. usfinspection Date: 3?c� Inspector: �r DO NOT REMOVE THIS NOTICE Reviewed for toning Compliance by the City of Wheat Ridge Planning Division APPROVED BY: DATE: �T� n % ( 0411 COMMENTS: i Architectural elevations shall match the approved master plan permit. aoaa chh 4062 of m il.� 4 b 4060 a050 4086 IJ ✓/ f — � 1 C ,tEh.,,.. No C.O. may be issued until public improvements are complete ' e`a040 U 1-Y �a�/tEF. a as identified in the Subdivision Improvement Agreement. APPROVED All landscaping shall be installed in accordance with the Reviewed for Code CorlGpli nce approved landscape plan (Case No. WZ-19-01) prior to C.O. and pursuant to the phasing identified in the Subdivision _ Improvement Agreement. Per the SIA, installation of - / PI Examiner D to landscaping, street trees, and irrigation is not required prior to n Certificate of Occupancy if issuance of the C.O. occurs outside Mdldtwosoe�.At: "M101o►,a0fape—it Of OPM-W Of 01"011 s I ono�s and,,mputatw= shoe not be o pert for, won apps al of Lny Vwtawn to of the planting season, generally October to June. a„ y of the prowf5iom of the bwlding code or o, Ote City ord. RrnrMte gauoMwng to g" mat," to vlok& or conel the the i ,oder or outer oretnot+des oivw Gtv shop not be gird. ADDRESS PLAN omm'n o!' 'e KEPHART Evergreen D11 t ,' a n H� ADDRESS PLAN City of W heat jjdge COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 August 27, 2019 OFFICIAL ADDRESS CHANGE NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: See Page 2 FORMER ADDRESS: Vacant Land • Subdivision: Clear Creek Crossing Subdivision Filing No. 2, Block 1, Lot 2, Section Parcel #: 39-194-04- 009 NOTES: This is a courtesy notification. AUTHORIZED BY: l- � t� DATE: c1 r DISTRIBUTION: 1. Property Owner 2. Addressinggieffco.us Jefferson County Assessor: Data Control, Lacey Baker; Jefferson County Elections: Holly Roth; Jeffco IT Services (Mapping): Steve Mitchel 3. Jeffco Public Schools, ATTN: Communication Services, 1829 Denver West Dr., Bldg. 27, Golden, CO 80401 4. U.S. Post Office, 1100 Johnson Rd., Golden CO 80401 5. Email to erlinda i.martinez &usps.aov and arlene.a.vickrey(&,,usps.gov and sheena.l.abeytaAusps.gov 6. Xcel Energy, sandra.cardenas(iDxcelenergy.com 7. Century Link, Capacity Provisioning Specialist, 5325 Zuni St., Room 728, Denver, CO 80221 8. Comcast, Attn: Scott Moore, 6850 S. Tucson Way, Englewood, CO 80112 9. Consolidated Mutual Water District 10. Applewood Sanitation District 11. West Metro Fire District 12. Wheat Ridge Planning Division 13. Wheat Ridge Building Division 14. GIS Specialist 15. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.ci.wheatridge.coms DATE: CLEAR CREEK Vicinity Map U95 A N