Loading...
HomeMy WebLinkAbout5922 W. 37th PlacePermit#:202002139 city of ',Wheat�ge COMMUNITY DMIOPMLNT 7500 W. 29th Ave Wheat Ridge CO 80033 6713 CERTIFICATE OF OCCUPANCY 5922 W 37th PI, Wheat Ridge, CO 80212 Date: W/08/22 This certificate verifies that Me building constructed and/or the use proposed of the building and/or premises, under the above permit number and on property described below, does comply with the Wheal Ridge Building Code, Zoning and other related land use and development laws of the City of Wheat Ridge, and may be occupied for the use specified. OWNER: BTM 37TH LLC 3080 Fenton St, Wheat Ridge. CO 80216 CONTRACTOR: HARTWOOD, LLC 6136 Fenton St, Deaver, 0080212 PARCEL: 39-251-07023 5922 W 37th PI, Wheat Ridge, 00 80212 ZONING: R1 -C TYPE OF CONST: V -B OCCUPANCY: R-3 OCC LOAD: 0 CODE EDITION: M181CC/2020 NEC SPRINKLERS: No FOR THE PURPOSE: SFD:Single Family- New Limitations/Stipulations:none No change shall be made in the Use of this building without prior notice and a new CERTIFICATE OF OCCUPANCY from the City of Wheat Ridge Certificate MUST be posted by front door of commercial occupancies COnsc �, Chief Building Oficial Planning2oning Administrator Cornelia Orzescu Lauren Mikulak i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: M i S , WQ& Job Address: SOZl 0 314"' `pL Permit Number: 2.0 2-CC'2_ I ❑ No one available for inspection: Time /0: 3 <,* (A2 PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. AV,Date:3- 1- 2 �Z- l Inspector: DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE -�� Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE R, Inspection Type: t syr _T�,+ Job Address: Permit Number: -ef% i * -- _ K ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Tz Inspector: DO NOT REMOVE THIS NOTICE Inspection Type: Job Address: Permit Number: CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE ♦, I s_ CITY OF WHEAT RIDGE ® Building Inspection Division (303) 235-2355 Office INSPECTION NOTICE Inspection Type: �f Z K 7— Job Address: -a Z Z- 3 7 f � Permit Number: } ❑ No one available for inspection: Time . ' - �KMyPM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date:_7 — Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: , I ,J/ � 5 i Permit Number: 7:. J 27 ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE q- It 4' CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: F-0 0,r_ Job Address: 7, Z- W -� / Z`_" Permit Number: 77—e 70 e9 U No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE City of Wheat Ridge Single Family - New PERMIT - 202002139 PERMIT NO: 202002139 ISSUED: 12/21/2020 JOB ADDRESS: 5922 W 37th Pl EXPIRES: 12/21/2021 JOB DESCRIPTION: New single family home with attached 2 car garage - 3,733 sq ft total *** CONTACTS *** OWNER ( 5 6 3) 542-5068 BTM 37TH LLC GC (563)542-5068 BRENT METZ TYLER DIVINE 190272 HARTWOOD, LLC SUB (303)659-3143 ALEJANDRO GUERRERO 021696 RAYO ELECTRIC, INC. SUB (720)695-4256 TONY GARCIA 080073 TONY GARCIA PLUMBING SUB (303)364-8256 BRYAN & JEREMY GRAY 120139 ROAD RUNNER HVAC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: UA / Unassigned BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 526,476.00 FEES Total Valuation 0.00 Plan Review Fee 21509.36 Use Tax 11, 056.00 Permit Fee 31860.55 Engin. Review Fee 150.00 ** TOTAL ** 17,575.91 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. Owner/Contractor is responsible for locating property lines and constructing improvements according to the approved plan and required development standards. The City is not responsible for inaccurate information submitted within the plan set and any construction errors resulting from inaccurate information. As part of the foundation inspections and PRIOR TO proceeding with any further construction/inspections, a completed, signed and sealed, Foundation Setback and Elevation Certification shall be submitted to the City for review. The certification form shall be fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating that the foundation was constructed in compliance with all applicable minimum setback and elevation requirements of the City. Prior to project completion or granting of a Certificate of Occupancy, an As -Built Survey or Improvement Survey Plat shall be submitted to the City. For one- or two-family dwellings, the first twenty-five feet (25&#39;) of driveway area from the existing edge of pavement into the site shall be surfaced with concrete, asphalt, brick pavers or similar materials. A right-of-way permit may be required; contact Public Works Department at 303-235-2861. BASEMENT NOT APPROVED AS AN INDEPENDENT DWELLING UNIT. Prior to issuance of a CO, 1 tree(s) shall be planted within the front setback. In addition, no less than twenty-five percent (25°%) of the gross lot area and no less than one hundred percent (100°%) of the front yard shall be landscaped. No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. All landscaping shall be in conformance with Section 26-502 of the Zoning and Development Code. All landscaping shall be installed in accordance with the approved landscape plan prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 125°% of the cost of the installation shall be required. I, by my signatu e, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable build ng codes, and all applicable mu icipal codes, policies and procedu es, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunctton with this ermrt. I further attest that I am leggally authorized to include all entities named within this document as parties to the work to be performed and that all work to be pertormed is disclosed n this document and or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) 1. This permit was issued based on the information provided in the subectto the compliance with those documents, and all applical 2. This.permit shall expire 365 days after the date of.issuance rega received prior to the date of expiration. An extension of no more Officlal and may be subiect to a fee equal to one-half of the one 3. dtober any new Date rmit application and accompanying plans and specifications and is statutes, ordinances, regulations, policies and procedures. ss of activity. Requests for extension must be made in writing and an 180 days made be granted at the discretion of the Chief Building L ermitfee. If of a new permit shall be subject to the standard Re -issuance or extension of expired permits is at the sole discretion of the unlet bunging utnciai ano is not guarantees. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.co. us To: CommDev Perm is Subject: Online Form Submittal: New Residential Construction Date: Monday, October 19, 2020 12:44:56 PM New Residential Construction THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 5922 W 37th Place Property Owner Name BTM 37th LLC Property Owner Phone 563-542-5068 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email Brent@hartwoodhome.com Address Attach City of Wheat Xerox Scan 10132020133924.Ddf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name BTM 37th LLC What Is your role In the Property Owner, General Contractor project? Wheat Ridge 190272 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contact Phone Number 563-542-5068 (enter WITH dashes, eg 303-123-4567) Contact Email Address Brent@hartwoodhome.com for Plan Review Comments Retype Contact Email Brent@hartwoodhome.com Address DESCRIPTION OF WORK Detailed Scope of New SFR with 2 car attached garage. Work - Example: New single family home with 2 car attached garage Square Footage of 3733 New Construction Upload Proof of Water Sewer Proof of submit ndf Submission to Water Department Upload Proof of MANJD2.odf Submission to Sanitation Department Upload Soils Report 5922 W. 37th Pl. Sl.odf Engineering Letters 5922 West 37th Place Fngineer ino 10 05 2020 set ndf and Other Letter Size Attachments Energy Calcs MANJD.odf Construction Plans Final Arch 5922 W 37TH 10 13 20 ndf scanned on 11'x17" or larger Project Value (contract 400000 Finished: 3,733sf (x) $122.46 = $457,143 value or cost of ALL Basement (finished): 1,130sf (x) $32.50 = $36,725 materials and labor) Basement (unfinished): 295sf (x) $22.45 = $6,623 Garage: 538sf (x) $48.30 = $25,985 Total: $526,476 SIGNATURE OF UNDERSTANDIN I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Brent Metz Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. Permit may be issued; approved with conditions (refer to attached) David F. Brossman, Development Review Engineer, 12/08/2020. Prior to issuance of the C.O. a Grading Certification Letter accompanied by an ILC shall be required from the Engineer of Record certifying that the final grading has been completed and is in general Conformance with the approved Grading Plan, and that the drainage shall function per the Final Drainage Report/Plan. Wlieaftp,�Idge CITY OF WHEATRIDGE BUILDING AND INSPECTION SERVICES DIVISION 7500 W 29th Ave Wheat Ridge, Co 80033-8001 p. 303.235.2855.f 303.237.8929 Proof of Submission for Permitting/Plan Review (Water and Sanitation only) A copy of this form must be completed by each water and sanitation agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: 1U ( �j'Z,� Project Address: �f_2- 2 t�J 3 -7 4- (- e Z Name of FirmAridividual submitting d j� documents: ✓ yeG Project Type/Description: / ��V C_ Sim K Signature of Firm Representative or Individual: I, William P. Willis * indicatedbelow and do, by my signature below, and approval ofthe indicated hereby acknowledge receipt of authorized documents ntative Of the agency necessary far project above. review Agency renrecented: (Please check one) o Wheat Ridge Water District Y9 Wheat Ridge Sanitation District o Consolidated Mutual Water District o Valley Water District O Clear Creek Sanitation District o Denver Water o Fruitdale Sanitation District o Westridge Sanitation District o Other Agency Notes: Must meet all District coordination and correspondence Proper Signature; ,, ,,I� (Agency'Representative) * District's consulting Engineer and standards including previous on fees an o servo ion must take place. 10-19-20 Wh6of at td c CITY or WHEATRIDGI; BUILDING AND INSmCTION sr.kvlClS DIVISION 7500 W 29th Ave Wheat Ridge, CO 80033.8001 p. 303,235.2855.,f 303.237.8929 Proof of Submission for Permitting/Plan Review (Water and Sanitation only) A copy of this form must be completed by each waterand sanitation agency indicated on the Permit Submittal Checklist for the project type and be attached to the Building Permit Application at the time of submission. Applications presented for submission without a completed Proof of Submission form from a required agency will not be accepted or processed. Date: 10Cl %2t9 Project Address: Name of Firm4ndividual submitting documents: --L 01 r-�-) �P Signature of Firm Representative or Individual: WANJEWWAAMMIMAAM the project indicated above. Aqency 'represented: (please check one) AK Wheat Ridge Water District o Consolidated Mutual Water District o Valley Water District o Denver Water Agency Notes: % S i Sig a re: te: ( gency R ese to v G � <�>ZI 4 am a duly authorized representative of the agency wledge receipt of documents necessary for review o Wheat Ridge Sanitation District o Clear Creek Sanitation District o Fruitdale Sanitation District o Westridge Sanitation District o Other I,S COMPLETE ENGINEERING SERVICES, INC. SUBSURFACE INVESTIGATION AND ENGINEERING ANALYSIS PROPOSED SINGLE FAMILY RESIDENCE 5922 West 37th Place Wheat Ridge, Colorado Prepared For: Hartwood Homes, LLC. 4134 Fenton St. Denver, CO 80212 Attention: Mr. Brent Metz It • - City of COMMUNITY UEVELUi'MENT APPROVED Reviewed for Code Comatiance Randy Slusser 11/06/2020 Plans Examiner Date Validkv of permit: The istuance of o permit or gpproval of plans sW4katbM and compufabons shah riot be o permit for, or an approve# of, any viciabon ea any of the provisions of the but ding rode or of ora► City ordinances. Aermlts presuming to give outhority to of WON or cancel the prw wm of the i odes or other ondtnoom of die City shoal not be valid Project Number: 20-11239 March 13, 2020 912 TWELFTH STREET, GOLDEN, CO 80401 303 279-6418 FAX: 303-279-9586 TABLE OF CONTENTS SCOPE................................................................1 PROPOSED CONSTRUCTION................................................1 SITE CONDITIONS......................................................1 SUBSURFACE CONDITIONS................................................2 FOUNDATION DESIGN SPECIFICATIONS.....................................3 DRAIN SYSTEMS........................................................4 FOUNDATION BACKFILL..................................................4 INTERIOR FLOOR SLAB CONSTRUCTION.....................................5 LAWN AND LANDSCAPE IRRIGATION........................................6 INSPECTION AND CONSULTATION..........................................7 FIGURES TEST HOLE LOCATION PLAN.......................................FIGURE 1 TEST HOLE LOG........................................................2 SWELL—CONSOLIDATION TEST RESULTS.....................................3 DRAIN SYSTEM DETAIL..................................................4 WINDOW WELL DETAIL...................................................5 City of Wheat Ridge Building Division PROJECT NO. 20-11239 March 13, 2020 Page 1 of 7 SCOPE A geotechnical and geological engineering investigation was conducted at 5922 West 37" Place, Wheat Ridge, Colorado, to determine foundation design specifications and basement floor system recommendations for a proposed single family residence. Recommendations for design and construction, based on soil and groundwater conditions, are provided. This investigation does not include evaluation of soil or groundwater for the presence of pollutants or other environmental hazards. Conclusions and recommendations presented are based on results of a field and labora ory investigation, other investigations conducted by this firm on adjacent and nearby lots, and experience with similar projects and conditions. PROPOSED CONSTRUCTION One single family residence will be constructed on the lot. The structure will be three stories with a full -depth basement. A. wood frame superstructure will be supported by a reinforced concrete foundation. SITE CONDITIONS The site is in a fully developed residential subdivision in Wheat Ridge, Colorado. A single family residence has been razed and removed. The surface in the -general vicinity slopes to the north at gentle grades. The surface within this lot is relatively flat. Vegetation was removed during demolition procedures. There are no apparent geologic hazards that should affect the proposed construction. City of Wheat Ridge Building Division PROJECT NO. 20-11239 March 13, 2020 Page 2 of 7 SUBSURFACE CONDITIONS Subsurface conditions were investigated by drilling one foundation design test hole as close as practical to an anticipated building envelope. Approximate test hole location is shown in Figure 1, Test Hole Location Plan. The test hole was drilled to a depth of 30 feet below existing grade and samples were taken at various intervals based on anticipated foundation bearing depths and materials encountered. The lithologic log and Standard Penetration test results are shown in Figure 2, Test Hole Log. Soils have been deposited by wind and low -to -moderate energy stream flow. The test hole encountered three feet of clayey fill over 17 feet of fine-grained, clayey sand overlaying claystone bedrock. Detailed soil descriptions are shown on Figure 2. Bedrock is present at approximately 20 feet below existing grade. Bedrock consisted of a sandy, firm to hard claystone to the total depth investigated. Bedrock has been mapped by the U.S.G.S. as the Denver and Arapahoe Formations. The Denver and Arapahoe Formations consist of interbedded sandstones, claystones, siltstones, shales and conglomerates. Bedrock will not affect foundation design or performance due to soil thickness. Detailed bedrock descriptions are shown on Figure 2. One representative soil sample from a depth of six feet below existing grade was tested to determine swell -consolidation potential. Test results indicate the soils encountered have low consolidation potential. The soil sample consolidated between 0.6 percent when saturated under a constant load of 1000 psf. Detailed swell - consolidation test results are presented in Figure 3. City of Wheat Ridge Building Division PROJECT NO. 20-11239 March 13, 2020 Page 3 of 7 Groundwater was encountered at a depth of 20 feet below existing grade during drilling operations. Free groundwater was present at a depth of 16 feet below existing grade when checked 11 days after drilling. Groundwater appears to be in a localized perched water table on top of the claystone bedrock. Due to the geologic and topographic location of the site, it is unlikely that groundwater will affect the residence during or after construction. Groundwater conditions can be better evaluated during construction by observing the foundation excavation. FOUNDATION DESIGN SPECIFICATIONS The foundation can be supported on continuous spread footings and isolated pads designed for a maximum contact pressure of 2000 psf. Maximum contact pressure shall be calculated using full dead load plus full live load. Footings shall be constructed on relatively undisturbed native soil that is smooth, even and free of organic materials, debris or rocks over three inches in diameter. Footings shall not be constructed on frozen or saturated soils. Foundation walls and other walls retaining soil that are restrained at the top shall be designed to withstand an at -rest lateral earth pressure of 45 lb/cu-ft/ft. Walls retaining soil that are not restrained at the top shall be designed using an active equivalent fluid pressure of 30 pcf/ft. A pull-out friction coefficient of 0.8 shall be used for soil retaining structures using geotextiles as reinforcement. An equivalent fluid pressure of 290 pcf/ft shall be used for passive lateral soil pressures. Concrete -to -soil friction coefficient shall be 0.4. City of Wheat Ridge Building Division PROJECT NO. 20-11239 March 13, 2020 Page 4 of 7 DRAIN SYSTEMS A drain system shall be constructed around the exterior basement foundation perimeter. The drain system shall be constructed in compliance with details shown in Figure 4, Drain System Detail, and shall be graded to a sump pit with an automatic pump. The pump shall discharge to the ground surface a minimum of 10 feet from the structure. Bottom of the sump should be above the seasonal high water level for normal -depth basement construction. Particular attention shall be given to placing polyethylene along the bottom of the exterior drain and up the foundation wall and to proper grading of drain pipes. Improper grading, such as high or low spots in the drain pipes, could result in damage to the foundation and superstructure by overwetting of foundation bearing soils. Window well drains shall be constructed in conformance with specifications contained in Figure 5, Window Well Details, and connected to the foundation drain system. FOUNDATION BACKFILL Backfill placed against foundation walls shall be free of trash and fragments of rock over six inches in maximum diameter, moistened and adequately compacted to prevent excessive settlement. Walls should be a minimum of seven days old prior to backfilling. Walls should be backfilled on both sides simultaneously. Controlled puddling shall not The ground surface shall slope away from the foundation. A minimum grade of 10 percent (one foot in ten) shall be provided within 10 feet of the structure, or as far as property boundaries permit, where the City of Wheat Ridge Building Division PROJECT NO. 20-11239 March 13, 2020 Page 5 of 7 surface is not covered -with concrete or other hardscaping. The owner should periodically inspect the surface around the foundation to locate and correct grading problems that may occur due to normal foundation backfill settlement. INTERIOR FLOOR SLAB CONSTRUCT -TON The builder.and/or owner should be aware that concrete floor slabs placed on native soil or bedrock may move if support materials become wet. Construction of a suspended floor over crawl space is one means of minimizing risk that slab movement will occur. Expansion potential of soils at, and below, interior floor bearing elevation indicates there is a low risk of significant floor slab movement. Procedures that will help improve slab performance, minimize potential for movement, and help prevent damage, if some risk of movement can be tolerated, are: 1. Subgrade should be prepared based on the soil type encountered. Granular soils should be wetted and thoroughly compacted prior to slab placement. Expansive materials should not be compacted more than necessary during excavation and construction. Clays and silts should not be allowed to dry excessively. The surface should be thoroughly wetted 24 hours prior to slab placement. 2. Concrete slabs should be reinforced with steel mesh and should be separated from all bearing members and utilities to allow independent movement ( i.e., a "floating slab"). 3. Joints should be scored in the slab at maximum 200 -square -foot areas. 4. A minimum void space of one -and -one-half inches should be con- structed above or below any nonbearing partition walls. In finished areas, any furring strips, drywall, paneling, etc., should stop a minimum of two inches above the floor. 5. Water pipes should not be placed under the floor slab if hot water is used. A flexible connection should be used to allow some movement between the furnace and the heating, ducts if -forced -air heating is used. City of Wheat Ridge Building Division PROJECT NO. 20-11239 March 13, 2020 Page 6 of 7 6. Flexible connections should be used on all mechanical systems placed on floor slabs. All plumbing which extends below floor slabs should have flexible connections and allowance for movement with the slab. 7. Foundation drain systems and landscaping should be completed in strict compliance with specifications contained herein to help prevent wetting of slab support soils. LAWN AND LANDSCAPE IRRIGATION Lawn and landscaping irrigation shall be controlled to prevent additional wetting of subsoils. Automatic sprinkling systems shall be placed so that, under full pressure, spray does not fall within five feet of foundation walls. Drip or mist irrigation systems shall not be placed within five feet of foundation walls. Instal -ling any portion of the irrigation system within five feet of walls should be avoided. Decorative landscape, such as rock and/or bark should be used in areas next to foundation walls. Vegetation planted within five feet of foundation walls should be hand watered and this watering should be minimized. Downspouts and sillcocks should not be allowed to discharge directly on the ground surface. Splash blocks and/or down spout extensions should be used to discharge water beyond foundation backfill where backfill soils are not covered by pavement and/or sidewalks. The owner is encouraged to read A Guide to Swelling Soils for Colorado Homebuyers and Homeowners, Special Publication No. 43, available from the Colorado Geological Survey. Recommendations contained in the report are applicable to all residential construction in the Denver area, regardless of soil expansion potential. City of Wheat Ridge I Building Division PROJECT NO. 20-11239 March 13, 2020 Page 7 of 7 INSPECTION AND CONSULTATION In any subsurface investigation it is necessary to assume conditions encountered in the field investigation are representative of the site. Actual conditions may differ from anticipated conditions. Subsurface conditions should be verified through visual inspection of the foundation excavation by a representative of this office prior to construction. Footing forms, reinforcing steel placement in foundation walls and drain system installation should also be inspected to ensure compliance with these recommendations and engineered foundation plans. We are available to discuss the contents of this report with you. Please contact us if you have questions or when further consultation or inspections are required. City of Wheat Ridge Building Division TEST HOLE LOCATION PLAN 5922 WEST 37TH PLACE WHEAT RIDGE .. COLORADO WEST 37TH PLACE _ TH-1 • � PROPOSED � SINGLE—FAMILY � RESIDENCE EXPLANATION • TH — 1 FOUNDATION DESIGN TEST HOLE 2O I 20 Test holes are located using taping and map SCALE: 1 " = 20' measurement. Locations should be considered BUILDING LOCATIONS accurate only to the degree implied by the ARE APPROXIMATE method used. eMP& �V PROJECT NO. 20-11239 COMPLETE ENGINEERING SERVICES City of FIGURE 1 Wheat Ridge Building Division TEST HOLE LOG TH-1 0— 7/12 5 ]10/12 y�l • '• • . •• 13/12 10— :. M. S— C -0.4% 10/12 15 — •• • r. 17/12 X20 25 — 50/12 30— EXPLANATION: FILL; clayey, slightly gravelly (course grained), sparse brick debris, firm, moist, brown (CL) `.r. SAND; fine grained, clayey, minor calcerous mottling, y loose to medium dense, moist, brown CLAYSTONE; sandy, fine grained sand, laminarly bedded, hard, moist, brown to greyish black Indicates location of standard penetration test. Indicates 13 blows with a 140 pound hammer falling 30 inches were required to drive a 2.5" diameter sampler 12 inches. S—C indicates sample tested for swell— consolidation potential & percent swell (+) or consolidation (—). Indicates approximate location of boundary between lithologic units. Transition may be gradual. Indicates depth to water measured at given number of days after drilling. Art V4 PROJECT N0. 20-11239 COMPLETE ENGINEERING SERVICES FIGURE 2 City of Wheat Ridge Building Division 3 z 2 0 us z a 1 W 0 be 1 2 z 0 0 3 0 cn 0 4 U SWELL- CONSOLIDATION TEST RESULTS At 1.0 10 APPLIED PRESSURE (k9f) PROJECT N0. 20-11239 COMPLETE ENGINEERING .SERVICES FIGURE 3c'ty of Wheat Ridge Building Division MOISTURE CONTENT: 19.0 pcf UNIT DRY WEIGHT: 104.1 pcf DESCRIPTION: Clayey sand, brown FROM: TH-1 AT 9 FEET Moll CONSOL UNDER CONSTANT PRESSURE DUE TO WETTING ���iiiiii�■■111111�■■111111 W-..�m �■■IIIIII�tl111111�■■111111 �■■111111■■111111■■111111 �■■111111■■111111■■111111 �■■111111■■111111■■111111 At 1.0 10 APPLIED PRESSURE (k9f) PROJECT N0. 20-11239 COMPLETE ENGINEERING .SERVICES FIGURE 3c'ty of Wheat Ridge Building Division FLOOR SYSTEM FOUNDATION WALL EXPANSION JOINT FLOOR SYSTEM + 5 MIL POLYETHYLENE DRAIN SYSTEM DETAIL FINAL GRADE COVER WITH +5 MILL PLASTIC AND DECORATIVE GRAVEL BACKFILL MINIMUM 4" CLEAN GRAVEL (MINUS 3/4") FOOTING ���d°Q •moo'. i� 11 MINIMUM 8" CLEAN GRAVEL (MINUS 3/4") 3" DIAMETER PERFORATED PIPE MINIMUM SLOPE 1/8" PER FOOT. DISCHARGE TO SUMP WITH AUTOMATIC PUMP OR GRAVITY OUTFALL. FOUNDATION EXCAVATION + 5 MIL POLYETHYLENE GLUED TO WALL AND EXTENDED ALONG BOTTOM OF EXCAVATION MIRAFI 140N FILTER FABRIC OR EQUIV. . T1151115" . rgrr. rrrLr. 7. Qo• QOri . ° D•� 45 DEG. MAX. eAAP,.=,& �� ih, mo PROJECT N0. � 20-11239 COMPLETE ENGINEERING SERVICES FIGURE 4 City of Wheat Ridge Building Division WINDOW WELL DETAIL NOTE: HARDSCAPED WINDOW WELL CANNOT BE CONNECTED TO PERIMETER FOUNDATION DRAIN. FLOOR SYSTEM EGRESS WINDOW MIN 3" CLEAN GRAVEL COMPACTED EARTH MIN 10% SLOPE FOUNDATION WALL EXPANSION JOINT FLOOR SYSTEM EXTERIOR PERIMETER DRAIN. RE: FIG. 5 em w-& AR V4 PROJECT NO. 20-11239 DEPTH OF WINDOW WELL VARIES WITH WINDOW ELEVATION AND GRADE WINDOW WELL 10 EMERGENCY LADDER COMPACTED EARTH OVERFLOW WINDOW DRAIN CONNECTED TO PERIMETER FOUNDATION DRAIN INLET SHALL BE MIN 6" ABOVE COMPACTED SOIL AND COVERED WITH A GRATE OR SCREEN COMPLETE ENGINEERING SER VICES FIGURE 5 City of Wheat Ridge Building Division EI N OVAERGY ONS Project Summary LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For Notes: Brent Metz Weather: Denver Internationa, CO, US Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Winter Design Conditions Summer Design Conditions Outside db 1 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 70 OF Design TD 17 OF Daily range H Relative humidity 50 % Moisture difference -37 gr/Ib Heating Summary Structure 33464 Btuh Ducts 0 Btuh Central vent (SER=65% 48 cfm) 1053 Btuh Heat recovery Humidification 3614 Btuh Piping 0 Btuh Equipment load 38131 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 2 (Tight) Heating Cooling Area (ft2) 3305 3305 Volume (ft3) 21258 21258 Air changes/hour 0.31 0.16 Equiv. AVF (cfm) 111 55 Heating Equipment Summary Make Carrier Equipment latent load Trade Carrier Performance 95 Single-... Btuh Model 59SP5A060E 17--14 18805 AHRI ref 4702805 Req. total capacity at 0.85 SHR Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 96.5 AFU E 60000 Btuh 46400 Btuh 52 OF Sensible Cooling Equipment Load Sizing Structure 18547 Btuh Ducts 0 Btuh Central vent (SER=65% 48 cfm) 257 Btuh Heat recovery Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 18805 Btuh Latent Cooling Equipment Load Sizing Structure -937 Btuh Ducts 0 Btuh Central vent (48 cfm) -985 Btuh Heat recovery Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 18805 Btuh Req. total capacity at 0.85 SHR 1.8 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 2 - - -' ►`� --- Coil C city of _ AHRI ref 9 %*rWheat Efficiency C0MMUNriY DEVELOPMENT LZ Sensible coolie Latent cooling APPROVED Total cooling 1000 cfm Actual air flow Reviewed for Code Compliance 0.030 in H2 cfm/Btuh Air flow factor Randy Slusser 11/06/2020 0.80 in H2O Static ressur Load sensible Plans Examiner Date Validity at permit, The issuance of a pemrMor Wprow! of pkns spec4kG(losM and canputcbons shoo not be o permit for, of an appeoW of any „oroaon tb any of the provislons of the burbling code or of pry CRY aedinuaxf. AermMa prewnong to give outhonty to sioloh of cancel the ptaH.sW4 of file Niltdfhg Calculations approved by ACCA to meet all requirement aodesorothawi&noaoesoftheptyehobratbewbd wrightscWt- 2020 -Oct -13 10:28:42 SCP. 1"11 -1 v 1�..,-r.,., Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ..\5922 W 37th\5922 W 37th_Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N EENERGY AED Assessment Job: 5922 W 37th Place i INNOVATIONS Date: October 13, 2020 LowerAH By: Max Nuttelman Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For Brent Metz Location: Denver Internationa, CO, US Elevation: 5430 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 1 Daily range (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 Cooling 92 28 ( H ) 60 7.5 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Moisture difference (gr/Ib) Infiltration: Hourly Glazing Load Heating 70 70 30 34.5 Hour of Day / Hourly 1-f Maximum hourly glazing load exceeds average by 32.2%. Zone does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 237 Btuh (PFG - 1.3*AFG) Cooling 75 17 50 -36.8 City of Wheat Ride wrightsc2ft® 2020 -Oct -13 10:28:42 Right -Suite® Universal 2019 19.0.12 RSU20087 Building Dkogn ACCP. ... \5922 W 37th\5922 W 37th—Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N EENERGY Building Analysis � INNOVATIONS LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For Brent Metz Location: Denver Internationa, CO, US Elevation: 5430 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 1 Daily range (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 Cooling 92 28 ( H ) 60 7.5 Component Btuh/ft2 Btuh % of load Walls 3.6 14112 37.0 Glazing 20.9 9279 24.3 Doors 27.1 569 1.5 Ceilings 1.7 265 0.7 Floors 1.4 2320 6.1 Infiltration 2.9 6919 18.1 Ducts 0 0 Piping 0 0 Humidification 3614 9.5 Ventilation 1053 2.8 Adjustments 0 Total 1 38131 100.0 Component Btuh/ft2 Btuh % of load Walls 0.6 2245 11.9 Glazing 24.7 10990 58.4 Doors 9.7 203 1.1 Ceilings 0.8 127 0.7 Floors 0.0 4 0.0 Infiltration 0.4 849 4.5 Ducts 0 0 Ventilation 257 1.4 Internal gains 4130 22.0 Blower 0 0 Adjustments 0 Total 1 1 188051 100.0 Latent Cooling Load = 0 Btuh Overall U -value = 0.060 Btuh/ft2-°F Data entries checked. Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 70 17 Relative humidity (%) 30 50 Moisture difference (gr/Ib) 34.5 -36.8 Infiltration: Method Simplified Construction quality Semi -tight Fireplaces 2 (Tight) W Glazing on ation nfiltration Dors r Walls 119 Internal Gains Infiltration Other Glazing City of L Wheat Ridge wriightsoft`" 2020-Qc ,13 10: 8;42 Right -Suite® Universal 2019 19.0.12 RSU20087 BUlling Pjyy son 14CCA ...\5922 W 37th\5922 W 37th -Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N EENERGY Component Constructions Job: 5922 W 37th Place i INNOVATIONS Date: October 13, 2020 LowerAH By: Max Nuttelman Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz Location: Denver Internationa, CO, US Elevation: 5430 ft Latitude: 40°N Outdoor: Heating Dry bulb (°F) 1 Daily range (°F) - Wet bulb (°F) - Wind speed (mph) 15.0 Construction descriptions Indoor: Heating Cooling ft2-°F/Btuh Indoor temperature (°F) 70 75 Walls Design TD (°F) 70 17 151319-Owc-8: Bg wall, heavy dry or light damp soil, 2"x6" wood int firm, Relative humidity (%) 30 50 Cooling Moisture difference (gr/Ib) 34.5 -36.8 92 Infiltration: 330 0.040 28 ( H ) Method Simplified 0.040 60 Construction quality Semi -tight 0.040 7.5 Fireplaces 2 (Tight) 0.058 Construction descriptions Or Area Ll -value ft2-°F/Btuh Btuh/ft2 ft2 Btuh/ft2-°F Walls 19.0 3.18 1050 151319-Owc-8: Bg wall, heavy dry or light damp soil, 2"x6" wood int firm, n 330 0.040 concrete wall, r-19 cav ins, 8" thk, 1/2" gypsum board int fnsh e 693 0.040 3.18 s 330 0.040 19.0 w 661 0.040 65 all 2013 0.040 R20 BC: Firm wall, wood ext, 1/2" wood shth, r-20 cav ins, 1/2" gypsum n 125 0.058 board int fnsh, 2"x6" wood firm e 712 0.058 4.05 s 273 0.058 20.0 w 478 0.058 314 all 1587 0.058 Partitions R20 BC: Firm wall, wood ext, 1/2" wood shth, r-20 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood firm Windows U30 S30: double pane low -e typical; 6.67 ft head ht Doors 11 DO: Door, wd sc type Ceilings R49 flat Floors 327 0.058 Insul R Htg HTM Loss Clg HTM Gain ft2-°F/Btuh Btuh/ft2 Btu Btuh/ft2 Btu 19.0 3.18 1050 0.12 40 19.0 3.18 2204 0.12 85 19.0 3.18 1050 0.12 40 19.0 3.10 2051 0.10 65 19.0 3.16 6356 0.11 230 20.0 4.05 507 1.15 144 20.0 4.05 2882 1.15 819 20.0 4.05 1104 1.15 314 20.0 4.05 1936 1.15 550 20.0 4.05 6429 1.15 1827 20.0 4.05 1326 0.57 188 n 70 0.300 0 20.9 1456 10.9 761 e 68 0.300 0 20.9 1413 33.4 2264 s 159 0.300 0 20.8 3308 17.4 2755 w 32 0.300 0 20.9 667 33.4 1069 w 117 0.300 0 20.9 2435 33.4 3903 all 445 0.300 0 20.9 9279 24.2 10753 n 21 0.390 0 27.1 569 9.65 203 150 0.025 49.0 1.74 262 0.83 125 1 0.025 49.0 1.74 3 0.83 1 all 152 0.025 49.0 1.74 265 0.83 127 20P -38c: Flr floor, firm flr, 12" thkns, carpet flr fnsh, r-38 cav ins, amb 16 0.030 38.0 2.09 32 0.22ity of 4 ovr Wheat Ride wrightsoft® 20 o-Qpt 0131 %8�� ^�- Right -Suite® Universal 2019 19.0.12 RSU20087 ulldln Ion Za \5922 W 37th\5922 W 37th_Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N 21A -32t: Bg floor, heavy dry or light damp soil, 8' depth 1646 0.020 0 1.39 2287 City of Wheat Ridge 41- wrightsoR, 202��JjjPP k&�rsion Righf-Suite® Universal 2019 19.0.12 RSU20087 age 2 ACCK y5922 W 371hv5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 Front Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Lower AH Open Bsmnt 2 Runnirg Feet of Exposed Wall 380.5 ft 96.0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.4 ft 9241.8 ft' 10.0 ft 1330.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 3305.2 ft' 1.0 x 809.3 ft 809.3 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 3446.6 ft' 0 809.3 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 330 1050 40 0 0 0 lQ/all R20 BC n 4.05 1.15 195 507 144 0 0 0 laz U30 S30 n 20.85 10.90 70 1456 761 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 693 2204 85 348 1106 42 11 lQ/all R20 BC e 4.05 1.15 779 2882 819 0 0 0 laz U30 S30 e 20.85 33.41 68 1413 2264 0 0 0 Wall 151319-0wc-8 s 3.18 0.12 330 1050 40 318 1011 39 lQ/all R20 BC s 4.05 1.15 431 1104 314 0 0 0 laz U30 S30 s 20.85 17.37 159 3308 2755 0 0 0 all 151319-0wc-8 w 3.10 0.10 693 2051 65 295 862 26 laz U30 S30 w 20.85 33.41 32 667 1069 16 334 535 l a/ R20 BC BCS30 w 4.05 1.15 595 1936 550 0 0 0 laz U3 0 w 20.85 33.41 117 2435 3903 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 348 1326 188 0 0 0 Door 11DO n 27.10 9.65 21 569 203 0 0 0 Ceil R49 flat - 1.74 0.83 150 262 125 0 0 0 Ceil R49 flat - 1.74 0.83 1 3 1 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 16 32 4 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 1646 2287 0 809 1125 0 Infiltration Heating Load (Btuh) 0.31 6919 551 Effect WAR WAR 12 Sensible Load (Btuh) ACH 1.00 849 0.08 68 0.16 Latent Load (Btuh) -1137 Internal a Occupants at 230 and 200 Btuh 1 230 200 0 0 0 b Scenario number 3900 900 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 33464 18547 -937 4989 1751 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 1053 257 -985 17 Winter Humidification Load Gal/Day 10.1 3614 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 237 141 21 1 Total Load Sum lines 13 through 19 38131 18805 0 4989 1751 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge YlF wrightsoR� 2020 -Oct -13102842 ••^..••...-...-•-•__......,_.. Right -suite® Universal 201919.0.12 RSU20087 Building DHiiisidn \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 Front Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Bsmnt Bath Unfin Storage 2 Runnirg Feet of Exposed Wall 5.5 ft 58.5 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.0 ft 330.0 ft' 10.0 ft 765.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 6.0 x 10.5 ft 63.0 ft' 1.0 x 298.7 ft 298.7 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 63.0 ft' 0 298.7 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 0 0 0 180 573 22 lQ/all R20 BC n 4.05 1.15 0 0 0 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 55 175 7 203 645 25 11 lQ/all R20 BC e 4.05 1.15 0 0 0 0 0 0 laz U30 S30 e 20.85 33.41 0 0 0 0 0 0 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 0 0 0 0 0 0 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 151319-0wc-8 w 3.10 0.10 0 0 0 203 645 25 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 l a/ R20 BC BCS30 w 4.05 1.15 0 0 0 0 0 0 laz U3 0 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 0 0 0 0 0 0 Door 11DO n 27.10 9.65 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 63 88 0 299 415 0 Infiltration Heating Load (Btuh) 0.31 32 336 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.00 4 0.05 41 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 294 10 2649 106 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -1 -8 21 1 Total Load Sum lines 13 through 19 294 10 2649 106 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ufh%% Ridane �� wrightsoR� �c "^"" """'-"""'•'• Right -Suite nU Universal 201919.0.12 RSU20087 2020 -Oct -13102842 \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 Front Door faces_ N Building 150sron EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Bsmnt Mech Guest BE 4 2 Runnirg Feet of Exposed Wall 15.8 ft 18.8 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.0 ft 350.0 ft' 10.0 ft 580.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 7.3 x 10.3 ft 74.3 ft' 1.0 x 200.3 ft 200.3 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 74.3 ft' 0 200.3 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 93 294 11 58 183 7 lQ/all R20 BC n 4.05 1.15 0 0 0 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 0 0 0 0 0 0 11 lQ/all R20 BC e 4.05 1.15 0 0 0 0 0 0 laz U30 S30 e 20.85 33.41 0 0 0 0 0 0 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 0 0 0 0 0 0 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 all 151319-0wc-8 w 3.10 0.10 65 207 8 130 337 6 laz U30 S30 w 20.85 33.41 0 0 0 16 334 535 l a/ R20 BC BCS30 w 4.05 1.15 0 0 0 0 0 0 laz U3 0 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 0 0 0 0 0 0 Door 11DO n 27.10 9.65 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 1 3 1 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 74 103 0 200 278 0 Infiltration Heating Load (Btuh) 0.31 90 108 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.01 11 0.02 13 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 1 230 200 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 0 0 1640 1008 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -2 200 21 1 Total Load Sum lines 13 through 19 0 0 1640 1008 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge YlF wrightsoR� 2020 -Oct -13102842 .SFA ••^�-•-••__.�....,_.. Right -suite® Universal 201919.0.12 RSU20087 Building Bim4Sion \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 Front Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Living Kitchen 2 Runnirg Feet of Exposed Wall 36.3 ft 32.8 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.4 ft 722.8 ft' 10.4 ft 982.8 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1.0 x 279.8 ft 279.8 ft' 1.0 x 446.3 ft 446.3 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 279.8 ft' 0 446.3 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 16 63 18 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 0 0 0 0 0 0 11 lQ/all R20 BC e 4.05 1.15 0 0 0 317 1239 352 laz U30 S30 e 20.85 33.41 0 0 0 11 235 376 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 164 280 80 23 95 27 laz U30 S30 s 20.85 17.37 95 1974 1644 0 0 0 lQ/all 151319-0wc-8 w 3.10 0.10 0 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 l a/ BC R20 BC w 4.05 1. 198 653 185 0 0 0 laz U3 0 w 20.85 33.4141 37 761 1220 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 0 0 0 0 0 0 Door 11DO n 27.10 9.65 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 9 16 8 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 9 19 2 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.31 1083 978 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.16 133 0.14 120 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 900 1200 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 4848 4176 2547 1977 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -13 -98 21 1 Total Load Sum lines 13 through 19 4848 4176 2547 1977 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge YlF ..............wrightsoR� 2020 -Oct -13102842 .......__.�....,_.. Right SuiieO Universal 201919.0.12 RSU20087 _ \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 From Door faces_ N Building Did?9e0M EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Entry/Hallway Pwdr 2 Runnirg Feet of Exposed Wall 16.0 ft 0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.4 ft 1029.6 ft' 10.4 ft 228.8 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1.0 x 281.1 ft 281.1 ft' 5.3 x 5.8 ft 30.2 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 281.1 ft' 0 30.2 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 55 110 31 0 0 0 laz U30 S30 n 20.85 10.90 27 570 298 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 0 0 0 0 0 0 11 lQ/all R20 BC e 4.05 1.15 99 400 114 0 0 0 laz U30 S30 e 20.85 33.41 0 0 0 0 0 0 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 13 53 15 0 0 0 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 151319-0wc-8 w 3.10 0.10 0 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 l a/ R20 BC BCS30 w 4.05 1.15 0 0 0 0 0 0 laz U3 0 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 117 474 67 0 0 0 Door 11DO n 27.10 9.65 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.31 478 0 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.07 59 0 0 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 2085 542 0 0 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -42 0 21 1 Total Load Sum lines 13 through 19 2085 542 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . A •w"""r"ig" h,."t... soR Wheat Ridge Right -suite® Universal 2019 19.0.12 RSU20087 2 BpYdQ*Ion \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 From Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Office Dining 2 Runnirg Feet of Exposed Wall 43.3 ft 13.8 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.4 ft 686.4 ft' 10.4 ft 592.8 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1.0 x 216.1 ft 216.1 ft' 13.5 x 15.0 ft 202.5 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 216.1 ft' 0 202.5 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 125 333 95 0 0 0 laz U30 S30 n 20.85 10.90 43 886 463 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 0 0 0 0 0 0 11 lQ/all R20 BC e 4.05 1.15 213 783 222 0 0 0 laz U30 S30 e 20.85 33.41 20 417 668 0 0 0 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 0 0 0 8 32 9 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 151319-0wc-8 w 3.10 0.10 0 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 l a/ BC R20 BC w 4.05 1. 112 453 129 135 370 105 laz U3 0 w 20.85 33.4141 0 0 0 44 913 1464 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 0 0 0 65 263 37 Door 11DO n 27.10 9.65 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 7 14 2 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.31 1292 411 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.19 159 0.06 50 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 900 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 4177 2448 1989 2248 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -190 583 21 1 Total Load Sum lines 13 through 19 4177 2448 1989 2248 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ride �� wrightsoR� "^"" """'^""'•'• Right -Suite nU Unrversa1201919.0.12 RSU20087 2020 -Oct -131028-42 . _ \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 Front Door faces_ N Building fttision EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Mud Bsmnt Halls 2 Runnirg Feet of Exposed Wall 0 ft 10.0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 10.4 ft 311.8 ft' 10.0 ft 740.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 6.8 x 9.3 ft 62.4 ft' 1.0 x 199.9 ft 199.9 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 62.4 ft' 0 199.9 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 0 0 0 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 0 0 0 88 279 11 11 lQ/all R20 BC e 4.05 1.15 0 0 0 0 0 0 laz U30 S30 e 20.85 33.41 0 0 0 0 0 0 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 13 40 2 lQ/all R20 BC s 4.05 1.15 0 0 0 0 0 0 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 151319-0wc-8 w 3.10 0.10 0 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 l a/ R20 BC BCS30 w 4.05 1.15 0 0 0 0 0 0 laz U3 0 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 14/all R20 BC - 4.05 0.57 166 589 83 0 0 0 Door 11DO n 27.10 9.65 21 569 203 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 0 0 0 Flat 21A -32t - 1.39 0.00 0 0 0 200 278 0 Infiltration Heating Load (Btuh) 0.31 0 57 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0 0 0.01 7 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 1158 266 915 28 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -21 -1 21 1 Total Load Sum lines 13 through 19 1158 266 915 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge �� wri9htsoR^ 2oftild11'VIDBlb`on .�`,A °.^.. •-•__......,_.. Right SuiteO Universal 201919.0.12 RSU20087 Page 7 \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 From Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Breakfast Nook 2 3 Running Feet of Exposed Wall Ceiling Ht (Ft) and Gross Wall Area (SgFt) 34.0 ft 15.4 ft 674.4 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 9.8 x 14.5 ft 141.4 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 282.8 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151319-0wc-8 n 3.18 0.12 0 0 0 lQ/all R20 BC n 4.05 1.15 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 Wall 151319-0wc-8 a 3.18 0.12 0 0 0 11 lQ/all R20 BC e 4.05 1.15 150 460 131 laz U30 S30 e 20.85 33.41 37 761 1220 Wall 151319-0wc-8 s 3.18 0.12 0 0 0 lQ/all R20 BC s 4.05 1.15 223 645 183 laz U30 S30 s 20.85 17.37 64 1334 1111 lQ/all 151319-0wc-8 w 3.10 0.10 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 l a/ R20 BC BC w 4.05 1. 150 460 131 laz U3 0 w 20.85 33.4141 37 761 1220 laz U30 S30 w 0.00 0.00 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 14/all R20 BC - 4.05 0.57 0 0 0 Door 11DO n 27.10 9.65 0 0 0 Ceil R49 flat - 1.74 0.83 141 246 118 Ceil R49 flat - 1.74 0.83 0 0 0 Ceil R49 vaulted - 0.00 0.00 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 Flat 20P -38c - 0.00 0.00 0 0 0 Flat 21A -32t - 1.39 0.00 0 0 0 Infiltration Heating Load (Btuh) 0.31 1504 Effect WAR 12 Sensible Load (Btuh) ACH 0.22 185 0.16 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 b Scenario number 0 13 c Default Adjustments d Custom Appliances 0 0 e Plants 0 14 Subtotals Sum lines 6 through 12 6172 3988 Duct EHLF&ESGF 0 0 0 0 15 Loads EEG 0 16 Ventilation Loads Vent Cfm 48 E Cfm 48 17 Winter Humidification Load Gal/Day 10.1 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -310 21 1 Total Load Sum lines 13 through 19 6172 3988 City of Wheat Ridge Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� wri9htsoR^ 20WWIA9I1DWsEon .�`,A °.^.. •-•__......,_.. Right SuiteO Universal 201919.0.12 RSU20087 Page 8 \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 From Door faces_ N EENERGY Load Short Form � INNOVATIONS LowerAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Clg 92 Method 75 Construction quality 17 Fireplaces H 50 -37 96.5 AFU E Area (ft2) 60000 Btuh 46400 Htg 52 Outside db (°F) 1 cfm Inside db (°F) 70 0.80 Design TD (°F) 70 Efficiency 12.0 EER, 15 SEER Daily range - 19040 Inside humidity (%) 30 3360 Moisture difference (gr/Ib) 34 22400 HEATING EQUIPMENT Make Carrier cfm Trade Carrier Performance 95 Single - Model 59SP5A060E 17--14 0.80 AHRI ref 4702805 1.00 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Clg 92 Method 75 Construction quality 17 Fireplaces H 50 -37 96.5 AFU E Area (ft2) 60000 Btuh 46400 Btuh 52 OF 1000 cfm 0.030 cfm/Btuh 0.80 in H2O Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Infiltration Simplified Semi -tight 2 (Tight) COOLING EQUIPMENT Area (ft2) Make Carrier Clg load (Btuh) Htg AVF (cfm) Trade CARRIER Open Bsmnt 809 Cond 24ACC424AO0300 1751 149 Coil CNPVP2417ALA+59SP5A060E17--14 AHRI ref 9764113 63 294 Efficiency 12.0 EER, 15 SEER 9 Sensible cooling 19040 Btuh Latent cooling 3360 Btuh Total cooling 22400 Btuh Actual air flow 1000 cfm Air flow factor 0.054 cfm/Btuh Static pressure 0.80 in H2O Load sensible heat ratio 1.00 280 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Open Bsmnt 809 4989 1751 149 94 Bsmnt Bath 63 294 10 9 1 Unfin Storage 299 2649 106 79 6 Bsmnt Mech 74 0 0 0 0 Guest BR 4 200 1640 1008 49 54 Living 280 4848 4176 145 225 Kitchen 446 2547 1977 76 107 Entry/Hallway 281 2085 542 62 29 Pwdr 30 0 0 0 0 Office 216 4177 2448 125 132 Dining 203 1989 2248 59 121 Mud 62 1158 266 35 14 Bsmnt Halls 200 915 28 27 2 B kfrea N k 141 6172 3988 184 ast oo Gild of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge + wrightsoft, 2021b�jIdfhW b10sion A1111el.=, ,,,n..Ll,,w„-,N�„y Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ACICK ..\5922 W 37th\5922 W 37th—Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N Lower AH 3305 33464 18547 1000 1000 Other equip loads 4667 257 Equip. @ 1.00 RSM 18805 Latent cooling 0 TnTAI c QQ(I; 04101 IQonr Innn Innn City of Wheat Ridge Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Building Division wrightsof — 2020Oct13 10:28:44 ....,-,.......F,„mF., Right Suiie® Universal 2019 19-0-12 RSU20087 Page 2 \5922 W 371h\5922 W 37th -Man AD 2020-09-17 rup Calc =MJ8 From Door faces. N EENERGY Duct System Summary Job: 5922 W 37th Place i INNOVATIONS Date: October 13, 2020 LowerAH By: Max Nuttelman Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.80 in H2O 0.38 in H2O 0.42 in H2O 0.230 / 0.190 in H20 0.063 in/ 1 00f 1000 cfm Cooling 0.80 in H2O 0.38 in H2O 0.42 in H2O 0.230 / 0.190 in H20 0.063 in/ 1 00f 1000 cfm 666 ft 108 Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Breakfast Nook c 1994 92 108 0.063 7.0 Ox 0 ShMt 59.5 305.0 st3 Breakfast Nook -A c 1994 92 108 0.066 7.0 Ox 0 ShMt 52.3 295.0 st3 Bsmnt Bath h 294 9 1 0.074 4.0 Ox 0 ShMt 20.8 290.0 st3 Bsmnt Halls h 915 27 2 0.075 4.0 Ox 0 ShMt 15.8 290.0 st3 Dining c 2248 59 121 0.073 7.0 Ox 0 ShMt 23.3 290.0 st3 Entry/Hallway h 2085 62 29 0.078 6.0 Ox 0 ShMt 11.3 285.0 st2 Guest BR 4 c 1008 49 54 0.073 5.0 Ox 0 ShMt 23.3 290.0 st3 Kitchen c 1977 76 107 0.072 7.0 Ox 0 ShMt 41.3 280.0 st3 Living c 2088 72 113 0.075 7.0 Ox 0 ShMt 42.8 265.0 st3 Living -A c 2088 72 113 0.071 7.0 Ox 0 ShMt 31.5 290.0 st3 Mud h 1158 35 14 0.077 5.0 Ox 0 ShMt 6.5 290.0 st3 Office c 1224 62 66 0.066 6.0 Ox 0 ShMt 31.5 315.0 st2 office -A c 1224 62 66 0.074 6.0 Ox 0 ShMt 34.8 275.0 st2 Open Bsmnt h 2494 75 47 0.071 6.0 Ox 0 ShMt 34.5 290.0 st3 Open Bsmnt-A h 2494 75 47 0.071 6.0 Ox 0 ShMt 46.5 275.0 st3 Unfin Storage h 2649 79 6 0.077 6.0 Ox 0 ShMt 24.0 275.0 1 st2 City of Wheat Ridge Building Division wrightsoft, 2020 -Oct -13 10:28:44 A1111el.=, ,,,,.�L1,1wa,1 ,�l., Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ACICK ..\5922 W 37th\5922 W 37th -Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 266 167 0.066 479 9.1 8 x 10 ShtMetl st3 Peak AVF 734 833 0.063 666 14.1 10 x 18 ShtMetl City of Wheat Ridge Building Division wrightsoft, 2020 -Oct -13 10:28:44 A1111el.=, ,,,,.�L1,1wa,1 ,�l., Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ACICK ..\5922 W 37th\5922 W 37th -Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N City of Wheat Ridge Building Division wrightsoR® 2020 -Oct -13 10 2a 44 Righi-Suiie® Universal 2019 19.0.12 RSU20087 Page 2 ACCK \5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces. N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Type Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 12X 10 264 102 301.8 0.063 485 10.0 OX 0 635 ShMt rt5A rb3 14X 16 379 478 292.5 0.065 615 11.4 8X 14 548 ShMt rt5 rb6 14X7 149 219 253.5 0.075 628 8.0 OX 0 10 x 22 ShMt rt6 rb4 14X5 159 146 272.3 0.070 457 8.0 OX 0 ShMt rt6 rb5 12X2 49 54 254.5 0.075 399 5.0 OX 0 ShMt rt5 City of Wheat Ridge Building Division wrightsoR® 2020 -Oct -13 10 2a 44 Righi-Suiie® Universal 2019 19.0.12 RSU20087 Page 2 ACCK \5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces. N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt5A PeakAVF 264 102 0.063 485 10.0 0 X 0 ShtMetl rt5 rt5 PeakAVF 692 635 0.063 623 13.2 10 X 16 ShtMetl rt2 rt6 PeakAVF 308 365 0.070 548 10.2 8 X 12 ShtMetl rt2 rt2 PeakAVF 1000 1000 0.063 655 15.1 10 x 22 ShtMetl City of Wheat Ridge Building Division wrightsoR® 2020 -Oct -13 10 2a 44 Righi-Suiie® Universal 2019 19.0.12 RSU20087 Page 2 ACCK \5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces. N EENERGY Static Pressure and Friction Rate Job: 5922 W 37th Place ll INNOVATIONS Date: October 13, 2020 LowerAH By: Max Nuttelman Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz External static pressure Pressure losses Coil Heat exchanger Supply diffusers Return grilles Filter Humidifier Balancing damper Other device Available static pressure Measured length of run -out Measured length of trunk Equivalent length of fittings Total length Total effective length Supply Ducts Return Ducts Supply Return Available Static Pressure Heating (in H2O) 0.80 0.26 0 0.06 0.06 0 0 0 0 0.42 Supply (ft) 26 34 305 0.9 Cooling (in H2O) 0.80 0.26 0 0.06 0.06 0 0 0 0 0.42 Return (ft) 4 23 275 ME Heating Cooling (in/ 100ft) (in/ 100ft) 0.063 OK 0.063 OK 0.063 OK 0.063 OK 4AD=60, 8AB=25, 8AB=25, 211=75, 1F1=120: TotalEL=305 8AE=10, 6M=20, 10A=75, 12F1=20, 10A=75, 6CB=25, 8E=10, 5A=40: Tota1EL=275 City of Wheat Ridge Building Division wrightsoft® 2020 -Oct -13 10:28:44 AAMRe• �. ,,rx,,•.•.�.,�,,, Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ...\5922 W 37th\5922 W 37th_Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N Basement F I I I I I I r I I I I I I I I I I I I I I I I I I I I MECH R��M I I I I I I I I I I I I I I I I I I L 1 L J Job #: 5922 W 37th Place Energy Innovations LLC Performed by Max Nuttelman for: Brent Metz Phone: 720.281.4554 www.eiboulder.com max0eiboulder.com City of Wheat Ridge Building Division Scale: 1 : 126 Page 1 Right -Suite@ Universal 2019 19.0.12 RSU20087 2020 -Oct -13 10:28:47 ..22 W 37th Man J&D 2020-09-17... N First Floor 10 OFF lour register or L J L J 108 4 PANTRY KITCHEIrVY-ducted to H- k T CL05ET -- --- --- --- reg'ter a10x4 -- _-- --- --- y 66 cfm x 4 14 x 8 y --- --- —� 10 159 a POW R ___ ____ ___ ___ E X107 B OKFF T 10x4 % 108 14x8 OYER 10x4 219 E®� 62 cfm F®� --- 14x16 478 pl U ,ox2 T 35 cfm tMUD OM G R LIVING ROOM 2 -CAR GARAGE ,oxa -------10,3C4 ,113 0x4 \/ 121 I City of Wheat Ridge Building Division Job #: 5922 W 37th Place Energy Innovations LLC Scale: 1 : 126 Performed by Max Nuttelman for: Page 2 Brent Metz Right -Suite@ Universal 2019 19.0.12 RSU20087 Phone: 720.281.4554 2020 -Oct -13 10:28:49 www.eiboulder.com max0eiboulder.com ...22 W 37th—Man J&D_2020-09-17... EI N OVAERGY ONS Project Summary UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For Notes: Brent Metz Weather: Denver Internationa, CO, US Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Winter Design Conditions Summer Design Conditions Outside db 1 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 70 OF Design TD 17 OF Daily range H Relative humidity 50 % Moisture difference -37 gr/Ib Heating Summary Structure 24155 Btuh Ducts 0 Btuh Central vent (SER=60% 57 cfm) 1435 Btuh Heat recovery Humidification 3502 Btuh Piping 0 Btuh Equipment load 29092 Btuh Infiltration Method Construction quality Fireplaces Sensible Cooling Equipment Load Sizing Structure 14046 Btuh Ducts 0 Btuh Central vent (SER=60% 57 cfm) 351 Btuh Heat recovery Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 14397 Btuh Simplified Latent Cooling Equipment Load Sizing Semi -tight 2 (Tight) Structure 78 Btuh Ducts 0 Btuh Central vent (57 cfm) -1174 Btuh Heating Cooling Area (ft2) 1980 1980 Volume (ft3) 24985 24985 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 90 45 Heating Equipment Summary Make Carrier Trade Carrier Performance 95 Single-... Model 59SP5A040E 17--12 AHRI ref 0 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Heat recovery Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 14397 Btuh Req. total capacity at 0.85 SHR 1.4 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 24ACA418CO0300 Coil CNPVP2417ALA+59SP5A040E17--12 AHRI ref 917'--- 96.5 AFU E 17 96.5AFUE Efficiency 40000 Btuh Sensible cooling 31200 Btuh Latent cooling 58 OF Total cooling 600 cfm Actual air flow 0.025 cfm/Btuh Air flow factor `►E, City of W heat �d 4e COMMUNITY DEVELOPMENT APPROVED 0.80 In H2O Static pressure Reviewed for Code Comaliance Load sensible he; Randy Slusser 11/06/2020 Plans Examiner Date Vsdidity at oetmit The issuance of o pew0f of ffpprosd of ptstns sped/kntlom Bold/italic values have been manually overridden and mmpurotrom shaNnot be o permlt(or, or an oppravot of any norobon b Calculations approved by ACCA to meet all requirements c any of the provlslom of the busdtng code or of opr my ordinances. permits presuming to glue outhortty to Wobte or oerkel the pro wopc of tete 0009 coda or other or*noom of the oty Mob not be rolA wrightsoit" SCP. Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ..\5922 W 37th\5922 W 37th_Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N EENERGY AED Assessment i INNOVATIONS UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Project • • For: Brent Metz Design Conditions Location: Indoor: Heating Cooling Denver Internationa, CO, US Indoor temperature (°F) 70 75 Elevation: 5430 ft Design TD (°F) 70 17 Latitude: 40°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 34.5 -36.8 Dry bulb (°F) 1 92 Infiltration: Daily range (°F) - 28 (H ) Wet bulb (°F) - 60 Wind speed (mph) 15.0 7.5 Hourly Glazing Load Hour of Day / Hourly 1-f Maximum hourly glazing load exceeds average by 21.5%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh City of Bold/italic values have been manually overridden wM,r m a,a.a,=omp,, Wheat Ridg wrightsc2t® 2fi2d3u�0$57 Right -Suite® Universal 2019 19.0.12 RSU20087 teni :e n A ..\5922 W 37th\5922 W 37th—Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N age EENERGY Building Analysis � INNOVATIONS UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz Location: Denver Internationa, CO, US Elevation: 5430 ft Latitude: 40°N Outdoor: Heating Cooling Dry bulb (°F) 1 92 Daily range (°F) - 28 ( H ) Wet bulb (°F) - 60 Wind speed (mph) 15.0 7.5 Component Btuh/ft2 Btuh % of load Walls 4.1 6575 22.6 Glazing 20.9 6660 22.9 Doors 0 0 0 Ceilings 1.7 4322 14.9 Floors 2.1 982 3.4 Infiltration 2.9 5616 19.3 Ducts 0 0 Piping 0 0 Humidification 3502 12.0 Ventilation Infiltration 1435 4.9 Adjustments 0 Floors Total Ceilings 29092 100.0 fffffffffffff■ Component Btuh/ft2 Btuh % of load Walls 1.2 1869 13.0 Glazing 22.4 7154 49.7 Doors 0 0 0 Ceilings 0.8 2068 14.4 Floors 0.2 117 0.8 Infiltration 0.4 689 4.8 Ducts 0 0 Ventilation 351 2.4 Internal gains 2150 14.9 Blower Infiltration 0 0 Adjustments 0 Floors Total Ceilings 14397 100.0 Latent Cooling Load = 0 Btuh Overall U -value = 0.055 Btuh/ft2-°F Data entries checked. Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Indoor: Heating Cooling Indoor temperature (°F) 70 75 Design TD (°F) 70 17 Relative humidity (%) 30 50 Moisture difference (gr/Ib) 34.5 -36.8 Infiltration: Method Simplified Construction quality Semi -tight Fireplaces 2 (Tight) rem Humidification Walls Ventilation Infiltration Glazing Floors Ceilings Walls Ventilation Internal Gains Infiltration Other Ceilings Glazing Bold/italic values have been manually overridden wrightsoft`� Right -Suite® Universal 2019 19.0.12 RSU20087 CK ..\5922 W 37th\5922 W 37th—Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N City of Wheat Ridge 1130 i ,°' bi� o� EENERGY Component Constructions � INNOVATIONS UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz Design Conditions Location: Indoor: Denver Internationa, CO, US Indoor temperature (°F) Elevation: 5430 ft Design TD (°F) Latitude: 40°N Relative humidity (%) Outdoor: Heating Cooling Moisture difference (gr/Ib) Dry bulb (°F) 1 92 Infiltration: Daily range (°F) - 28 ( H ) Method Wet bulb (°F) - 60 Construction quality Wind speed (mph) 15.0 7.5 Fireplaces Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Heating 70 70 30 34.5 Simplified Semi -tight 2 (Tight) Cooling 75 17 50 -36.8 Construction descriptions Or Area LI -value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ft2-°F/Btuh Btuh/ft2 Btu Btuh/ft2 Btu Walls R20 BC: Firm wall, wood ext, 1/2" wood shth, r-20 cav ins, 1/2" gypsum in 322 0.058 20.0 4.05 1305 1.15 371 board int fnsh, 2"x6" wood firm e 505 0.058 20.0 4.05 2046 1.15 581 s 269 0.058 20.0 4.05 1088 1.15 309 w 527 0.058 20.0 4.05 2136 1.15 607 all 1623 0.058 20.0 4.05 6575 1.15 1869 Partitions (none) Windows U30 S30: double pane low -e typical; 6.67 ft head ht n e s w all U30 S30: double pane low -e typical; 2 ft overhang (4.5 ft window ht, w 4.2 ft sep.); 6.67 ft head ht U30 S30: double pane low -e typical; 1.5 ft overhang (6 ft window ht, w 0.5 ft sep.); 6.67 ft head ht U30 S30: double pane low -e typical; 2 ft overhang (6 ft window ht, 0.5 w ft sep.); 6.67 ft head ht Doors (none) Ceilings R49 flat R49 vaulted: Vaulted, firm deck, 1/2" gypsum board int fnsh, 10" thkns, r-49 ceil ins Floors 128 0.300 0 20.9 2664 10.9 1393 80 0.300 0 20.9 1668 33.4 2673 34 0.300 0 20.9 702 17.4 585 37 0.300 0 20.9 766 33.4 1228 278 0.300 0 20.9 5800 21.1 5879 11 0.300 0 20.9 235 33.4 376 15 0.300 0 20.9 313 30.7 461 15 0.300 0 20.9 313 29.2 438 1034 0.025 49.0 1.74 1803 0.83 862 1446 0.025 49.0 1.74 2520 0.83 1205 20P -38c: Flr floor, firm flr, 12" thkns, carpet flr fnsh, r-38 cav ins, amb 58 0.030 38.0 2.09 121 0.25 14 ovr City of Bold/italic values have been manually overridden Wheat Ridge WPIghtSOft® 20�0-Opt-13 1 0857. ^�- Right -Suite® Universal 2019 19.0.12 RSU20087 tSUllding�a VISIOn 9 Za \5922 W 37th\5922 W 37th_Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N 20P -38c: Flr floor, frm fir, 12" thkns, carpet flr fnsh, r-38 cav ins, gar 413 0.030 38.0 2.09 861 0.25 102 ovr City of Bold/italic values have been manually overridden Wheat Ridge 41- wrightsoR, Page 2 2 Righf-Suite® Universal 2019 19.0.12 RSU20087 Page ACCK y5922 W 371hv5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 Front Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Upper AH Guest BE 1 2 Runnirg Feet of Exposed Wall 182.5 ft 22.5 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 12.6 ft 6658.9 ft' 9.0 ft 603.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1980.1 ft' 1.0 x 233.8 ft 233.8 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 49.1 2479.7 ft' 0 233.8 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151315-0wc-8 n 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 450 1305 371 0 0 0 laz U30 S30 n 20.85 10.90 128 2664 1393 0 0 0 lQlall 15B-10sfc-2 e 0.00 0.00 0 0 0 0 0 0 11 �Claz U30 S30 e 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 e 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC e 4.05 1.15 585 2046 581 203 699 199 laz U30 S30 e 20.85 33.41 80 1668 2673 30 626 1002 lQ/all 15B-10sfc-2 s 0.00 0.00 0 0 0 0 0 0 laz U30 S30 s 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 s 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 302 1088 309 0 0 0 laz U30 S30 s 20.85 17.37 34 702 585 0 0 0 lQ/all 15B-10sfc-2 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 lQ/all 151315-0wc-8 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 0 BC w 4.05 1. 605 2136 607 0 0 0 laz U3 U30 S30 w 20.85 33.4141 37 766 1228 0 0 0 laz U30 S30 w 20.85 33.41 11 235 376 0 0 0 laz U30 S30 w 20.85 30.73 15 313 461 0 0 0 laz w 20.85 29.21 15 313 438 0 0 0 14/all R20 BC BC - 0.00 0.00 0 0 0 0 0 0 Door 11D 11130 n 0.00 0.00 0 0 0 0 0 0 Ceil 166-30ad - 0.00 0.00 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 1034 1803 862 234 407 195 Ceil R49 vaulted - 1.74 0.83 1446 2520 1205 0 0 0 Flat 20P -38c - 2.09 0.25 58 121 14 0 0 0 Flat 20P -38c - 2.09 0.25 413 861 102 0 0 0 Flat 21A -32t - 0.00 0.00 0 0 0 0 0 0 Flat 2113-28t - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.22 5616 585 Effect WAR WAR 12 Sensible Load (Btuh) ACH 1.00 689 0.10 72 0.11 Latent Load (Btuh) -922 Internal a Occupants at 230 and 200 Btuh 5 1150 1000 1 230 200 b Scenario number 1000 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 24155 14046 78 2317 1667 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 57 E Cfm 57 1435 351 -1174 17 Winter Humidification Load Gal/Day 9.4 3502 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 0 -31 21 Total Load Sum lines 13 through 19 29092 14397 0 2317 1667 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WphQeat Ridge . A �� wr�ghtsoR� 57 Right -Sidle® Universal 201919.0.12 RSU20087 6l�llltl ingct �rvj ff \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 Front Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room Jack & Jill Guest BE 3 2 Runnirg Feet of Exposed Wall 3.3 It 34.8 It 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 8.0 It 316.0 ft' 9.0 ft 594.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 13.0 x 6.8 It 87.8 ft' 1.0 x 215.9 It 215.9 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 87.8 ft' 0 215.9 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151315-0wc-8 n 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 0 0 0 108 275 78 laz U30 S30 n 20.85 10.90 0 0 0 40 834 436 lQlall 15B-10sfc-2 e 0.00 0.00 0 0 0 0 0 0 11 �Claz U30 S30 e 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 e 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC e 4.05 1.15 0 0 0 185 697 198 laz U30 S30 e 20.85 33.41 0 0 0 13 261 418 lQ/all 15B-10sfc-2 s 0.00 0.00 0 0 0 0 0 0 laz U30 S30 s 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 s 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 26 78 22 0 0 0 laz U30 S30 s 20.85 17.37 7 139 116 0 0 0 lQ/all 15B-10sfc-2 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 lQ/all 151315-0wc-8 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 'N 0 BC w 4.05 1.15 0 0 0 20 82 23 laz U3 U30 S30 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 20.85 30.73 0 0 0 0 0 0 laz w 20.85 29.21 0 0 0 0 0 0 14/all R20 BC BC - 0.00 0.00 0 0 0 0 0 0 Door 11D 11130 n 0.00 0.00 0 0 0 0 0 0 Ceil 166-30ad - 0.00 0.00 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 88 153 73 216 376 180 Ceil R49 vaulted - 1.74 0.83 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 21A -32t - 0.00 0.00 0 0 0 0 0 0 Flat 2113-28t - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.2275 904 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.01 9 0.16 111 0.11 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 1 230 200 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 445 228 3452 1522 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 57 E Cfm 57 17 Winter Humidification Load Gal/Day 9.4 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 8 -162 21 Total Load Sum lines 13 through 19 445 228 3452 1522 Lily Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WheatRidge 2Oct 1 Right -Sidle® Universal 2019 19.0.12 RSU20087 Bpildi g 10 08 2 \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 Front Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room 2nd Mech Guest BE 2 2 Runnirg Feet of Exposed Wall 0 ft 30.0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 9.0 ft 184.5 ft' 8.7 ft 577.2 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 5.8 x 4.5 ft 25.9 ft' 1.0 x 250.3 ft 250.3 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 0 25.9 ft' 49.1 264.6 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. HeatingS-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151315-0wc-8 n 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 0 0 0 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 0 0 0 lQlall 15B-10sfc-2 e 0.00 0.00 0 0 0 0 0 0 11 �Claz U30 S30 e 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 e 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC e 4.05 1.15 0 0 0 0 0 0 laz U30 S30 e 20.85 33.41 0 0 0 0 0 0 lQ/all 15B-10sfc-2 s 0.00 0.00 0 0 0 0 0 0 laz U30 S30 s 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 s 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 0 0 0 200 702 199 laz U30 S30 s 20.85 17.37 0 0 0 27 563 469 lQ/all 15B-10sfc-2 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 lQ/all 151315-0wc-8 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 'N 0 BC w 4.05 1.15 0 0 0 1 497 141 laz U30 S30 U3 w 20.85 33.41 0 0 0 11 11 235 376 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 20.85 30.73 0 0 0 0 0 0 laz w 20.85 29.21 0 0 0 0 0 0 14/all R20 BC BC - 0.00 0.00 0 0 0 0 0 0 Door 11130 11D n 0.00 0.00 0 0 0 0 0 0 Ceil 166-30ad - 0.00 0.00 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 26 45 22 223 389 186 Ceil R49 vaulted - 1.74 0.83 0 0 0 42 73 35 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 21A -32t - 0.00 0.00 0 0 0 0 0 0 Flat 2113-28t - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.22 0 966 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0 0 0.17 119 0.11 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 1 230 200 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 0 0 3424 1668 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 57 E Cfm 57 17 Winter Humidification Load Gal/Day 9.4 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -2 -86 21 Total Load Sum lines 13 through 19 0 0 3424 1668 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge YlF wrightsoR^ 2020-Oct1310:08:57 .SFA ••^� �--•-••__.�....,_.. Right -suite® Universal 201919.0.12 RSU20087 Building Bim4Sion \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 From Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room 2nd Halls M Closet 2 Runnirg Feet of Exposed Wall 11.5 ft 16.0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 14.1 ft 1295.1 ft' 16.5 ft 644.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1.0 x 371.1 ft 371.1 ft' 1.0 x 135.9 ft 135.9 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 49.1 485.6 ft' 49.1 207.6 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151315-0wc-8 n 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 8 31 9 0 0 0 laz U30 S30 n 20.85 10.90 0 0 0 0 0 0 lQlall 15B-10sfc-2 e 0.00 0.00 0 0 0 0 0 0 11 �Claz U30 S30 e 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 e 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC e 4.05 1.15 98 299 85 0 0 0 laz U30 S30 e 20.85 33.41 24 500 802 0 0 0 lQ/all 15B-10sfc-2 s 0.00 0.00 0 0 0 0 0 0 laz U30 S30 s 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 s 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 45 184 52 8 30 9 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 15B-10sfc-2 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 lQ/all 151315-0wc-8 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 'N 0 BC w 4.05 1.15 0 0 0 153 572 163 laz U3 U30 S30 w 20.85 33.41 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 11 235 3766 laz U30 S30 w 20.85 30.73 0 0 0 0 0 0 laz w 20.85 29.21 0 0 0 0 0 0 14/all R20 BC BC - 0.00 0.00 0 0 0 0 0 0 Door 11130 11D n 0.00 0.00 0 0 0 0 0 0 Ceil 166-30ad - 0.00 0.00 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 154 269 129 0 0 0 Ceil R49 vaulted - 1.74 0.83 331 577 276 208 362 173 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 20P -38c - 2.09 0.25 0 0 0 0 0 0 Flat 21A -32t - 0.00 0.00 0 0 0 0 0 0 Flat 2113-28t - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.22 436 463 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.08 54 0.08 57 0.11 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 500 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 2320 1387 1662 1330 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 57 E Cfm 57 17 Winter Humidification Load Gal/Day 9.4 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -30 53 21 Total Load Sum lines 13 through 19 2320 1387 1662 1330 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge .�`,A °.^.. .. ,.-•-.•__......,_.. Righ4Suite nU 9'4r8thebWMn Universal RSU20087 �e 4 \5922 W 371h\5922 W 37th -Man J&D 2020-09-17 rup Calc =MJ8 From Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room M Bath Guest Bath 1 2 Runnirg Feet of Exposed Wall 14.8 ft 5.0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 16.8 ft 775.7 ft' 16.8 ft 326.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1.0 x 235.9 ft 235.9 ft' 9.3 x 5.0 ft 46.3 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 49.1 360.5 ft' 49.1 70.7 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151315-0wc-8 n 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 0 0 0 52 163 46 laz U30 S30 n 20.85 10.90 0 0 0 11 235 123 lQlall 15B-10sfc-2 e 0.00 0.00 0 0 0 0 0 0 11 �Claz U30 S30 e 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 e 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC e 4.05 1.15 0 0 0 0 0 0 laz U30 S30 e 20.85 33.41 0 0 0 0 0 0 lQ/all 15B-10sfc-2 s 0.00 0.00 0 0 0 0 0 0 laz U30 S30 s 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 s 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 23 94 27 0 0 0 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 15B-10sfc-2 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 lQ/all 151315-0wc-8 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 'N 0 BC w 4.05 1. 129 418 119 0 0 0 laz U3 U30 S30 w 20.85 33.4141 26 532 852 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 20.85 30.73 0 0 0 0 0 0 laz w 20.85 29.21 0 0 0 0 0 0 14/all R20 BC BC - 0.00 0.00 0 0 0 0 0 0 Door 11D 11130 n 0.00 0.00 0 0 0 0 0 0 Ceil 166-30ad - 0.00 0.00 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 0 0 0 Ceil R49 vaulted - 1.74 0.83 360 628 301 71 123 59 Flat 20P -38c - 2.09 0.25 0 0 0 38 80 9 Flat 20P -38c - 2.09 0.25 146 304 36 4 9 1 Flat 21A -32t - 0.00 0.00 0 0 0 0 0 0 Flat 2113-28t - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.22439 149 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.08 54 0.03 18 0.11 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 0 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 2415 1653 758 232 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 57 E Cfm 57 17 Winter Humidification Load Gal/Day 9.4 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 264 -25 21 Total Load Sum lines 13 through 19 2415 1653 758 232 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge �� wrightsoR^ 2020-Oct1310:08:57 cA ••W 371h\59•__.°..373 Right -suii 0 Universal017 2019 le 0.M Front Building Di'�on \5922 W 37iM5922 W 37th -Man J&D 2020-09-1Zrup Calc =MJ8 From Door faces_ N EENERGY i INNOVATIONS Right -J8® Form A UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eibouldercom Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman 1 Name of Room M Bedroom Laundry 2 Runnirg Feet of Exposed Wall 36.8 ft 8.0 ft 3 Ceiling Ht (Ft) and Gross Wall Area (SgFt) 16.8 ft 939.3 ft' 9.0 ft 351.0 ft' 4 Room Dimensions (Ft) and Floor Plan Area (SgFt) 1.0 x 283.9 ft 283.9 ft' 8.5 x 11.0 ft 93.5 ft' 5 Ceiling Slope (Deg.) and Gross Ceiling Area (SgFt) 49.1 433.9 ft' 0 93.5 ft' Type of Const., Panel HTM Area or Btuh Area or Btuh Exposure Number Faces Length Length Htg. Clg. Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 151315-0wc-8 n 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC n 4.05 1.15 283 835 237 0 0 0 laz U30 S30 n 20.85 10.90 77 1595 834 0 0 0 lQlall 15B-10sfc-2 e 0.00 0.00 0 0 0 0 0 0 11 �Claz U30 S30 e 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 e 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC a 4.05 1.15 28 115 33 72 237 67 laz U30 S30 e 20.85 33.41 0 0 0 14 281 451 lQ/all 15B-10sfc-2 s 0.00 0.00 0 0 0 0 0 0 laz U30 S30 s 0.00 0.00 0 0 0 0 0 0 Wall 151315-0wc-8 s 0.00 0.00 0 0 0 0 0 0 lQ/all R20 BC s 4.05 1.15 0 0 0 0 0 0 laz U30 S30 s 20.85 17.37 0 0 0 0 0 0 lQ/all 15B-10sfc-2 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 lQ/all 151315-0wc-8 w 0.00 0.00 0 0 0 0 0 0 laz U30 S30 w 0.00 0.00 0 0 0 0 0 0 'N 0 BC w 4.05 1. 170 567 161 0 0 0 laz U30 S30 U3 w 20.85 33.4141 0 0 0 0 0 0 laz U30 S30 w 20.85 33.41 0 0 0 0 0 0 laz U30 S30 w 20.85 30.73 15 313 461 0 0 0 laz w 20.85 29.21 15 313 438 0 0 0 14/all R20 BC BC - 0.00 0.00 0 0 0 0 0 0 Door 11130 11D n 0.00 0.00 0 0 0 0 0 0 Ceil 166-30ad - 0.00 0.00 0 0 0 0 0 0 Ceil R49 flat - 1.74 0.83 0 0 0 94 163 78 Ceil R49 vaulted - 1.74 0.83 434 756 362 0 0 0 Flat 20P -38c - 2.09 0.25 20 41 5 0 0 0 Flat 20P -38c - 2.09 0.25 263 548 65 0 0 0 Flat 21A -32t - 0.00 0.00 0 0 0 0 0 0 Flat 2113-28t - 0.00 0.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh) 0.22 1390 208 Effect WAR WAR 12 Sensible Load (Btuh) ACH 0.25 171 0.04 26 0.11 Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 2 460 400 0 0 0 b Scenario number 0 500 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines 6 through 12 6473 3286 890 1073 Duct EHLF&ESGF 0 0 0 0 0 0 15 Loads EEG 0 0 16 Ventilation Loads Vent Cfm 57 E Cfm 57 17 Winter Humidification Load Gal/Day 9.4 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 60 -49 21 Total Load Sum lines 13 through 19 6473 3286 890 1073 City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. to/hoat alrl a� �� wrightsoR^ 2020-Oct1310:08:57 w •W ---•-•__. 37t R;nJ&Dl000eO 91sa12o1sle19 oM Front BuildingDivp39b�1 \5922 W 37iM5922 W 37th -Man J&D 2020-09-1Zrup Calc =MJ8 From Door faces_ N EENERGY Load Short Form � INNOVATIONS UpperAH Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com W For: Brent Metz Htg Clg Outside db (°F) 1 92 Inside db (°F) 70 75 Design TD (°F) 70 17 Daily range - H Inside humidity (%) 30 50 Moisture difference (gr/Ib) 34 -37 HEATING EQUIPMENT Make Carrier Trade Carrier Performance 95 Single - Model 59SP5A040E 17--12 AHRI ref 0 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 96.5 AFU E Area (ft2) 40000 Btuh 31200 Btuh 58 OF 600 cfm 0.025 cfm/Btuh 0.80 in H2O Method Construction quality Fireplaces Job: 5922 W 37th Place Date: October 13, 2020 By: Max Nuttelman Infiltration Simplified Semi -tight 2 (Tight) COOLING EQUIPMENT Area (ft2) Make Carrier Clg load (Btuh) Htg AVF (cfm) Trade CARRIER Guest BR 1 234 Cond 24ACA418CO0300 1667 58 Coil CNPVP2417ALA+59SP5A040E17--12 AHRI ref 9171705 88 445 Efficiency 12.5 EER, 15 SEER 11 Sensible cooling 14535 Btuh Latent cooling 2565 Btuh Total cooling 17100 Btuh Actual air flow 600 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.80 in H2O Load sensible heat ratio 1.00 371 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Guest BR 1 234 2317 1667 58 71 Jack & Jill 88 445 228 11 10 Guest BR 3 216 3452 1522 86 65 2nd Mech 26 0 0 0 0 Guest BR 2 250 3424 1668 85 71 2nd Halls 371 2320 1387 58 59 M Closet 136 1662 1330 41 57 M Bath 236 2415 1653 60 71 Guest Bath 1 46 758 232 19 10 M Bedroom 284 6473 3286 161 140 I --4— OA o()n 1 (170 77 ^ 0- Bold/italic values have been manually overridden City Of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge Wrl htsOft'� 2W0t-131 D9.:00 „kP, ag,,r Right -Suite® Universal 2019 19.0.12 RSU20087 tSUilc�mg �I gleio 1 ACICA \5922 W 37th\5922 W 37th—Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N Upper AH 1980 24155 14046 600 600 Other equip loads 4937 351 Equip. @ 1.00 RSM 14397 Latent cooling 0 TnTni c anon nnnnn nom r_nn r_nn Bold/italic values have been manually overridden City of Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wheat Ridge wrightsoR® B`PBftbiifls° W ....,-,.......F,„mF., Right Suiie® Universal 2019 19.0.12 RSU20087 Page 2 \5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces. N EENERGY Duct System Summary Job: 5922 W 37th Place i INNOVATIONS Date: October 13, 2020 UpperAH By: Max Nuttelman Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.80 in H2O 0.30 in H2O 0.50 in H2O 0.274 / 0.226 in H20 0.061 in/ 100ft 600 cfm Cooling 0.80 in H2O 0.30 in H2O 0.50 in H2O 0.274 / 0.226 in H20 0.061 in/ 100ft 600 cfm 819 ft 59 Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk 2nd Halls c 1387 58 59 0.094 5.0 Ox 0 ShMt 20.8 270.0 st4 Guest BR 1 c 1667 58 71 0.077 6.0 Ox 0 ShMt 47.0 310.0 st4 Guest BR 2 h 3424 85 71 0.073 6.0 Ox 0 ShMt 57.3 320.0 st4 Guest BR 3 h 3452 86 65 0.067 7.0 Ox 0 VIFx 31.8 380.0 st5 Guest Bath 1 h 758 19 10 0.070 4.0 0x0 VIFx 24.5 370.0 st5 Jack & Jill h 445 11 10 0.079 4.0 Ox 0 ShMt 49.3 300.0 st4 Laundry c 1073 22 46 0.090 5.0 Ox 0 ShMt 25.3 280.0 st4 M Bath c 1653 60 71 0.063 7.0 0x0 VIFx 27.1 405.0 st5 M Bedroom h 3236 80 70 0.065 7.0 0x0 VIFx 30.3 390.0 st5 M Bedroom -A h 3236 80 70 0.067 7.0 0x0 VIFx 38.9 370.0 st5 M Closet c 1330 41 57 0.061 6.0 0x0 VIFx 34.3 415.0 st5 City of Wheat Ridge wrightsof ,2Q- t-13 Q:0�:Q0 A 59221111Pl.P, "e Ha1i1.1,1.',Jl., Right -Suite® Universal 2019 19.0.12 RSU20087 tSUlldIng Dbage 1 n ACIC1- W 37th\5922 W 37th -Man J&D_2020-09-17.rup Calc = V,18 Front Door faces: N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 233 257 0.073 463 8.8 8 x 10 ShtMetl sti st5 Peak AVF 367 343 0.061 467 12.0 0 x 0 ShtMetl sti sti Peak AVF 600 600 0.061 600 12.6 8 x 18 ShtMetl City of Wheat Ridge wrightsof ,2Q- t-13 Q:0�:Q0 A 59221111Pl.P, "e Ha1i1.1,1.',Jl., Right -Suite® Universal 2019 19.0.12 RSU20087 tSUlldIng Dbage 1 n ACIC1- W 37th\5922 W 37th -Man J&D_2020-09-17.rup Calc = V,18 Front Door faces: N City of Wheat Ridge wri htsoR® ,2p�iloom-1gacco9-coo .....9.. .._. ,.m. Righi-SudeU Universal 201919.0.12 RSU20087 15011 ftlflg UIVIPageI ACCK _ A5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces_ N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Type Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb7 12X4 80 105 249.0 0.091 393 7.0 Ox 0 343 ShMt rt3 rb9 12x 10 262 268 369.3 0.061 491 10.0 Ox 0 617 ShMt rt4 rb10 12X4 105 75 369.8 0.061 391 7.0 Ox 0 ShMt rt4 rb8 12X4 96 81 350.3 0.064 360 7.0 Ox 0 ShMt rt3 rb2 12X3 58 71 360.8 0.063 363 6.0 Ox 0 ShMt rt3 City of Wheat Ridge wri htsoR® ,2p�iloom-1gacco9-coo .....9.. .._. ,.m. Righi-SudeU Universal 201919.0.12 RSU20087 15011 ftlflg UIVIPageI ACCK _ A5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces_ N Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 PeakAVF 233 257 0.063 463 9.1 8 x 10 ShtMetl rt1 rt4 PeakAVF 367 343 0.061 550 10.5 8 x 12 ShtMetl rt1 rt1 PeakAVF 600 600 0.061 617 12.6 10 x 14 ShtMetl City of Wheat Ridge wri htsoR® ,2p�iloom-1gacco9-coo .....9.. .._. ,.m. Righi-SudeU Universal 201919.0.12 RSU20087 15011 ftlflg UIVIPageI ACCK _ A5922 W 371h\5922 W 37th—Man AD 2020-09-17 rup Calc =MJ8 From Door faces_ N EENERGY Static Pressure and Friction Rate Job: 5922 W 37th Place ll INNOVATIONS Date: October 13, 2020 UpperAH By: Max Nuttelman Energy Innovations LLC Phone: 720.281.4554 Email: max@eiboulder.com Web: www.eiboulder.com For: Brent Metz External static pressure Pressure losses Coil Heat exchanger Supply diffusers Return grilles Filter Humidifier Balancing damper Other device Available static pressure Measured length of run -out Measured length of trunk Equivalent length of fittings Total length Total effective length Supply Ducts Return Ducts Supply Return Available Static Pressure Heating (in H2O) 0.80 0.12 0 0.06 0.06 0.06 0 0 0 0.50 Supply (ft) 24 11 415 449 Cooling (in H2O) 0.80 0.12 0 0.06 0.06 0.06 0 0 0 0.50 Return (ft) 5 10 355 Heating Cooling (in/ 100ft) (in/ 100ft) 0.061 OK 0.061 OK 0.061 OK 0.061 OK 4AD=60, 215=110, 11G=5, 11G=5, 8AB=25, 9A1=80, 8E=10, 1F1=120: TotalEL=415 6M=205 6C6=115, 6CB=25, 10A=75, 8D1=805 5A=40: Tota1EL=355 City of Wheat Ridge wrightsoft® 21§Uftdilhf 'Wi$Qon AAMRe• �. ,,rx,,•.•.�.,�,,, Right -Suite® Universal 2019 19.0.12 RSU20087 Page 1 ...\5922 W 37th\5922 W 37th_Man J&D_2020-09-17.rup Calc = MJ8 Front Door faces: N Second Floor Job #: 5922 W 37th Place Energy Innovations LLC Performed by Max Nuttelman for: Brent Metz Phone: 720.281.4554 www.eiboulder.com max@eiboulder.com City of Wheat Ridge Building Division Scale: 1 : 123 Page 1 Right -Suite@ Universal 2019 19.0.12 RSU20087 2020 -Oct -13 10:09:03 22 W 37th Man J&D_2020-09-17.rup 4 City of � WheatRige COMMUNITY DEVELOPMENT City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 October 7, 2019 OFFICIAL ADDRESS CHANGE NOTIFICATION is hereby given that the following address has been assigned to the property/properties as indicated below: NEW ADDRESS: 5868 (Lot 4),5886 (Lot 3),5904 (Lot 2) and 5922 (Lot 1) West 37" Place of the Metz Estates Subdivision CURRENT ADDRESS: 5890 and 5910 West 371 Place • Fred L Spallone Subdivision, Lot 19,18 and 10, Section Parcel #:39-251-07-006 and 39-251-07-007 NOTES: This is a courtesy notification. AUTHORIZED BY: DATE: M 17119 DISTRIBUTION: 1. Property Owner 2. Addressing_@jeffco.us Jefferson County Assessor: Data Control, Lacey Baker; Jefferson County Elections: Holly Roth; Jeffco IT Services (Mapping): Steve Mitchel 3. Jeffco Public Schools, ATTN: Communication Services, 1829 Denver West Dr., Bldg. 27, Golden, CO 80401 4. U.S. Post Office, 3700 Tennyson St., Denver CO 80212 5. Email to arlene.a.vickrey(&usps.gov; mariann.szasz(d)usps.gov; carmen.s.suarezAusps.goy; theresa.a.kraftAusps.gov 6. Xcel Energy, iacob.van.laere(&xcelenerg, 7. Century Link, robert.davisAcenturylink.com; rachel.weaver(&centurylink.com 8. Comcast, scott mooreAcable.comcast.com 9. WR Water District: barrv(d,wrwdistrict.com 10. WR Sanitation District: bwillis(-&martinmartin.com; infoAwheatridgesanitation.com; mbakarichAmorainco. com; 11. Fire Department: planreview(&westmetrofire.org 12. Wheat Ridge Planning Division 13. Wheat Ridge Building Division 14. GIS Specialist 15. Log File NOTE: Please notify all other parties concerned. ADDRESS MAP UPDATED BY: www.ci.w heatridge.com s DATE: Vicinity Map a LOTS. LOT 23 A LOfM LOT27 LOTM LOT 20 [OT!8 LOT 79 � zcmm c zolm •L xa+t•3 r}r b7m R,c MRS W, aacc a. = tars r. n: H d: i j liJ'V • IEdY EE9'a?f ` ftr ►y �'3 g :Y JI'riN _ _ W 3_TfH PL-- — -- — — — — — — aso u----- -- --- r. - nr--- {� f V.YY I• 1e •'.nb. E�.. �• i/ oauraz yx.w\L• i ` dJDP �zEm 901 � F9 _ LOT 16 y. ul Ir � I L;i ut; 3 Ip� zo'm Aae p LOT 7 '• LOT 2 I / LOT 3 LO? 4 x 4 o� LOTis 5922 i 5904 j I - 5868 gmLOT, LCNRD A -1C i MST ASR.' w R is r L sc.n vid. 8' arn.+. BLOCK BLOCK2 -7 t" w..�n • 5886 FR2DLlPALLmPe SLID NVBSM a 11 I 1 mKcn.,� 8 LOT Y. i �+q m -$I F��M't 1YY .{LLrltlf, r ^ AW wWS W777.7 �Lc..n R zr 7fv Vt