Loading...
HomeMy WebLinkAbout7803 W 43rd PlaceYork Engineering Structural Design ( 7 2 0 ) 990-5900 Date: March 22, 2021 Attn: Thrive Home Builders Subject: Framing Observation, 7503, 7507, and 7511 West 43rtl Place, Wheat Ridge CO The purpose of this letter is to report on the framing of the townhome, located at 7503, 7507, and 7511 West 43rtl Place. A representative of York Engineering visited the site to inspectthe framing provided on the approved set of plans by York Engineering. It appears that the framingwas installed accordingto the approved set of plans provided by York Engineering. Please feel free to call with any questions or concerns. Respectfully yours, Kelby M. York, P.E. York Engineering Structural Design ( 7 2 0 ) 990-5900 Date: March 22, 2021 Attn: Thrive Home Builders Subject: Shear Wall Observation, 7503, 7507, and 7511 West 43rtl Place, Wheat Ridge CO The purpose of this letter is to report on the shearwalls of the townhome, located at 7503, 7507, and 7511 West 43rtl Place. A representative of EV Studio visited the site to inspect the shearwalls and hold downs provided on their approved set of plans. See shear and hold down letter provided by EV Studio. It appears that the shearwalls were installed according to the approved set of plans provided by York Engineeringwith the following retrofits: • Added blocking and straps to windows as needed where force transfer wall detail is called out. • Provided 11-7/8" LVL blocking at header height and HDDS hold downs on P1 at front garage for portal frame detail callout. This letter does not include framing or interior shear. Framing shall be inspected ata later date. Gypsum and firewalls are to be inspected bythe city. Please feel free to call with any questions or concerns. Respectfully yours, Helena N. Dopita, P.E. January 27, 2021 TH Yarrow Gardens LLC 1875 Lawrence Street, Suite # 900 Denver, CO 80202 Re: Exterior Shear and Hold Down Letter Yarrow Gardens Townhomes 7803, 7807, 7811 W. 43rd Place L1 B3 F3 Wheat Ridge, CO 80033 On January 27, 2021 EVstudio was requested to observe the installation of exterior shear walls and hold downs at the above addresses. Our representative was able to verify the exterior shear and hold downs were installed in the proper locations per the structural drawings prepared by EVstudio. This letter does not include framing or interior shear, which was inspected at a later date or gypsum, and firewalls which are to be inspected by the city. Please feel free to contact our office with any questions or concerns. Sincerely, Dominic Chapman Field Inspector Sincerely, o plc 1V V4��o (�• '��A,�cjf�0 u 4.6537 i Al Ross Maxwell, PE Assistant Director of Structural Engineering 5335 W 481h Ave. Suite 300 303.670.7242 ph design@evstudio.com Denver. CO 80212 303.679.1862 fax www.evstudio.com 5Q 0 LA o to r N N 00 m NtO� N o a d) t6 N O A Q o1 L', 0 C d-+ W cr. w GP 40 V tM u 0 C)w - UJ W 4) cc ++ %0 Co Ln O O 1, in N w Ln to An. O 0 yh V)4 V} Ln 11 11 sT C C Q O iJ \4 �d 10 LL A O a tet► � _�Mspc S e n ^ I O E _ ry IA c N 'G w KT E(� //�� L• 01 O c� c �, QU a 90 1 d C M N V M 4- 3 O = > C R w 1 w p b .0 v O w Lu a� rn X C LL 'n o ?� G V .� O l7 G C> U v1 O 4: V� 7 �.. 41 E q Gn O -.n ^ >, srm iy �� 0>1co c� '•' J W M C C C .v C: ' M > > O • .� 14 = m� T j w 'j EE L O Q Q A Y L,20 m Q `" `- til A -7E E m a :2 E o m o •i (q, - O b V l7 L}7 = W C °C� uz%0 z a 10 Wt7w W N � �� C O Ln C O^ - V Z Z W W o N wRI Y. c LLu W. ro 0� OC k- ?; o cc d a' ++ %0 Co Ln O O 1, in N w Ln to An. O 0 yh V)4 V} Ln 11 11 sT C C Q 13) cc r� � a v W C;, -0- U 0- V Ln O iJ 10 LL A W a tet► � S e n ^ I O E Obd V W yYY EO C W N v Ln w KT E(� //�� L• 01 O c� c �, QU a dee C M N V M 4- 3 O = > C R w 1 w p b .0 v O 13) cc r� � a v W C;, -0- U 0- V Ln O iJ 10 LL A ° aMO. S e n ^ I O Obd V W yYY EO C Tm CO � m Q m N C w Lu w rn LL 'n l7 G C> v1 M rv) 7 N 7 U N O v W Q N LJ C .v 9J • .� N C j a. S V1 L N N m y of r� • '- Q 71 - (q, O Ln O L V C = W c fL 7 u U- ® m y h- L1 Ln N Li Q S y a N OG Z �L E O' -O u E v N C v O 0 iu C L, M = NA O j < 00 '^ w C hA j VI v '� E O -a n _� •�tli V F C O E O 41 01 y -10 -0 O L 2 _IV O W m o = G I- O r_ M V +w+ N> ro y S U O ro 7 C a LL 9 L > ro z B O < O Z1 E 7 R] G J ti Z E C 0. E C V a " Z) o ° aMO. S e n ^ I O Obd V W yYY EO C Tm CO � m Q m N 7863 W 43rd Cir 'Nheat Ridge, C❑ 80033 Thrive Home Builders EnergyLogic May 6. 1021 �.o Verified using Ekoirope I Version 3.2.1.26671 Builder Name: Thrive Horne Builders Rating Company: EnergyLogic Permit Date/Number: Rater ID (RTIN): 7592832 Home Address: 7803 W 43rd Cir, Wheat Ridge, CO Rating Date: 2029-05-06 80033 Version: 3.0 I ' - Thermal Enclosure System Water Management System A complete thermal enclosure system that includes A comprehensive water management system to comprehensive air sealing, quality -installed insulation protect roofs, walls, and foundations. and high -performing windows to deliver improved ❑ comfort and lower utility bills. Flashing, a drainage plane, and site grading to move water from the roof to the ground and then away Air Infiltration Test: 462 CFM50 (1.62 ACH50) from the home. Primary Insulation Levels: Water-resistant maferias on below -grade walls and underneath slabs to Ceiling: R-50 Floor: R-68 reduce the potential for water entering into the home. Wall: R-30 Stab: R-5 Management of moisture levels In building materials during construction. Primary Window Efficiency: U -Value: 0.3 SHGC:0.33 Heating, Cooling, and Ventilation Energy Efficient Lighting and System Appliances a A high -efficiency heating, cooling system, and Energy efficient products to help reduce utility bills, ventilation system that is designed and installed for while providing high -equality performance optimal performance. ENERGY STAR Qualified Lighting: 100% Total Duct Leakage. Duct Leakage to Outdoors_ 41 CFM @ 25Pa (Rough -In, with 20 CFM @ 25Pa (1.261 100 Its) ENERGY STAR Qualified Appliances and Fans: Air Handler) Refrigerators: 0 Dishwashers: 0 Primary Beating (Sys(em Type - Fuel Type • Efficiency). Ceiling Fans: 0 Exhaust Fans: 1 Furnace a Natural Gas a 96.5 AFUE Primary Water Heater (System Type • Fuel Type - Efficiency)* Primary Cooling (System Type - Fuel Type - Efficiency): Water Heater • Natural Gas a 0.96 Energy Factor Air Conditioner• Electric a 13 SEER This ceirtifcate provides a summary of the major energy eftienry and other construction Index features that contribute to this harne earna g the ENERGY STAR including its Home Energv Rating System (I IERS) score. as determined through independent inspection and vadfication Zero Energy Reference Existing pxrfarrned by a u.m.d pwfescxa�ar Th. 14 000 Energv Rabna system is a nationally-reciignke Home Home Homes uniform measurement of the energy efficiency of homes Note that when a home onntains IrUl iple perfdrmancs levels for a particular feature (e.g . ILfR® •nmdow et[rclency a insulation revels). the predununanl value Is shown. Also, homes may ti . o 4 Y r r certified to earn the ENERGY STAR using a santpfing prulv[zrl. v+fiereby one borne is randomly Le!s mare selected From a set of homes fer representative inspections and testing. In such cases, the fh►rey E...ey feature.(eWld Irl each hour. Y,ffiw the 3 [are Ildelided to rlreel w exceed the values presented • on this certificate. The actual values for your home may diffen but offer equivalent or better performance I his cerliticate veal printed using hRe rcpe'v i's. — 3.2 4.2e67l. This Name ¢11513 RF4:n f+!ffir1 m!n at 1MY1tlINrBySiinBOVitlOmarlHftRB! ENERGY STAR V3 Home Report Property Organization 7803 W 43rd Cir EnergyLogic Wheat Ridge, CO 80033 Quinn Stedman Model: P3 E Community: Westridge Builder Thrive Home Builders 7803 W 43rd Cir Thrive Report Mandatory Requirements Inspection Status 2021-05-06 Rater ID (RTIN): 7592832 RESNET Registered (Confirmed) ✓ Duct leakage at post construction better than or equal to ENERGY STAR 013.1 requirements. ✓ Envelope insulation levels meet or exceed ENERGY STAR v3/3.1 requirements. ✓ Slab on Grade insulation must be > R-5, and at IECC 2009 Depth for Climate Zones 4 and above. ✓ Envelope insulation achieves RESNET Grade I installation, or Grade II with insulated sheathing. ✓ Windows meet the 2009 IECC Requirements - Table 402.1.1. ✓ Duct insulation meets the EPA minimum requirements of R-6. ✓ Mechanical ventilation system is installed in the home. V ENERGY STAR Checklists fully verified and complete. OnPrgyLogio thr pns yy o<,�coni HERS Index Target Reference Home HERS J SAF (Size Adjustment Factor) 1.00 SAF Adjusted HERS Target 70 As Designed Home HERS 29 As Designed Home HERS w/o PV 49 Normalized, Modified End -Use Loads (MBtu I year) ENERGY STAR As Designed Heating 18.9 11.7 Cooling 3.1 4.4 Water Heating 8.4 2.0 Lights and Appliances 18.8 16.2 Total 49.2 34.3 This home MEETS or EXCEEDS the energy efficiency requirements for designation as an EPA ENERGY STAR Qualified Home under Version 3.0 Pollution Prevented Energy Cost Savings $/yr Type of Emissions Reduction Heating 101 Carbon Dioxide (CO:) - tons/yr 5.0 Cooling -18 Water Heating 67 Lights 8 Appliances 93 Generation Savings 414 Total 657 The energy savings and pollution prevented are calculated by comparing the Rated Home to the ENERGY STAR Version 3.0 Reference Home as defined in the ENERGY STAR Qualified Homes HERS Index Target Procedure for National Program Requirements, Version 3.0 promulgated by the Environmental Protection Agency (EPA). In accordance with the ANSI/RESNET/ICC 301-2014 Standard, building inputs affecting setpoints infiltration rates, window shading and the existence of mechanical systems may have been changed prior to calculating loads Ekotrope RATER - Version 3.2.4.2667 All results are based on data enterad by Ekotrnpe users Ekotrope disclaims all liability for the information shown on this report IECC 2012 Performance Compliance Property 7803 W 43rd Cir Wheat Ridge, CO 80033 Model: P3 E Community: Westridge 7803 W 43rd Cir Thrive Report. Organization EnergyLogic Quinn Stedman Builder Thrive Horne Builders Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status 2021-05-06 Rater ID (RTIN): 7592832 RESNET Registered (Confirmed) Annual Energy Cost IECC 2012 Performance $338 $60 $145 $543 $449 $0 $992 Requirements As Designed $219 $91 $145 $454 $447 $0 $902 As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements o` Chapter a of the adopted Irlematiaral Energy Conservation Cade based on Climate Zane If rating is Projected l versify that the building design described harem is consistent faith the building plans specifications. and other calculations submitted vrith the permit app4cation V rating is Confirmed. I cell, that the address referenced above has been inspected,tested and that the mandatory provisions o'!he IECC have been installed to meet or exceed the intent of the IECC or A,ll be veriried as such ba another party. Name: Organization: Quinn Stedman EnergyLogic Signature: Digitally signed: pw�* 564k.44 516/21 at 3:16 PM Eicotropp RATER - Version 3.2.4.2667 IECC 2412 Performance compliance results calculated using Ekotrope P.ATER's anergy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Toot All results are based on data entered by Ekotrope users Ekotrope disclaims all liability For the information shoran on this report 405.3 herfcrmance-based compliance passes by 16.24'0 40241 2 Air Leakage Testing Air sealing is 1.62.ACH at 50 Pa. It must not exceed 3.00 AGR at 50 Pa 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration V -Factor 403.2.2 Duct Testing R40-1 1 Lighting Equipment Efficiency R403.5.1 Mechanical Ventilation Efficacy Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met R405.2 -lu_' Insulation Design exceeds requirements for IECC 2012 Performance compliance by 16.2%. As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements o` Chapter a of the adopted Irlematiaral Energy Conservation Cade based on Climate Zane If rating is Projected l versify that the building design described harem is consistent faith the building plans specifications. and other calculations submitted vrith the permit app4cation V rating is Confirmed. I cell, that the address referenced above has been inspected,tested and that the mandatory provisions o'!he IECC have been installed to meet or exceed the intent of the IECC or A,ll be veriried as such ba another party. Name: Organization: Quinn Stedman EnergyLogic Signature: Digitally signed: pw�* 564k.44 516/21 at 3:16 PM Eicotropp RATER - Version 3.2.4.2667 IECC 2412 Performance compliance results calculated using Ekotrope P.ATER's anergy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Toot All results are based on data entered by Ekotrope users Ekotrope disclaims all liability For the information shoran on this report Clf) 0 co M V ,; W's m ® 4u 0 o 4) _ V/ ; 31. a� m Z> CL CV) (0 N U (}4 p U 0 LO N c m En O C O U- c d n � (p c o ci W LL W C C W CO I` a Li- W (M C/) C: p Lo M 2 al Co C i • U} t0 b 'c U 'A p TU N0 c at�i (ll N W (6 `N v oV CL EL V • 6 C b l� L p N N (6 O O i' JD p Z o f0 .0 N A (ll v (D Q 0 U c U � iQ (A N -,t LL Q ) VI 'a p5 G G C Q y� C!) 0 ro _ oz r L t�6 N O W o L o U U •y Q +'+ W+ V Uo C N U 'rnlu m ro _ m'2 =_W W = 6 �0) L �+ O L Cc C S c N ,u M - ••• �0€>6 O M ti '0 " a2'i E ME a E -0 S7 � o r`unv3o y Lo Q a N N 14 E: C � v r p M Q U a 9 C) O LO lC CD rym bi 11• 4.1.E LL W V _ u �w Q [SOI O N Q` Z [If 0� C ro ro Q M O - o o E a ~ fz O ro u � C as n L C 0 ' o C LL R 4i ra ui a E 4 d ? cw L3 U. o m 7, Z> CL CV) (0 N U (}4 p U 0 LO N c m En O IECC 2012 Label 7803 W 43rd Cir Model: P3 E Ekotrope RATER - Version: 3.2.4.2667 HERSO Index Score: 29 -1310100g, Olive -O Sperm Ceiling: R-50 Above Grade Walls: R-30 Foundation Walls: NIA Exposed Floor: R-68 Slab: R-5 Infiltration: 462 CFM50 (1.62 ACH50) Duct Insulation: Supply: R0, Return: R0 Duct Lkg to Outdoors: 20 CFM @ 25Pa (1.28 / 100 ft2) Window 4 Door Nes e U -Value: 0.3, SHGC: 0.33 Door: R-5 Mechanical 8quipment Specs Heating: Furnace - Natural Gas - 96.5 AFUE Cooling: Air Conditioner • Electric • 13 SEER Hot Water: Water Heater • Natural Gas - 0.96 Energy Factor Average Mechanical Ventilation: 44 CFM 3u I Desn Profmss'€ Viral t Signature: _ _ _ Air Leakage Report Property Organization Inspection Status Onerovi c ]it" 7803 W 43rd Cir EnergyLogic 2021-05-06 rrt�Nrs�r�y;o;] Wheat Ridge, CO 80033 Quinn Stedman Rater ID (RTIN): 7592832 Model: P3 E RESNET Registered Community: Westridge Builder (Confirmed) Thrive Home Builders 7803 W 43rd Cir Thrive Report General Information Conditioned Floor Area [ft2] 1,565 Infiltration Volume [ft'] 17,108 Number of Bedrooms 2 Air Leakage Measured Infiltration 462 CFM50 (1.62 ACH50) ACH50 (Calculated) 1.62 ELA [sq. in.] (Calculated) 25.41 ELA per 100 s.f. Shell Area (Calculated) 0.591 CFM50 (Calculated) CFM50 / s.f. Shell Area (Calculated) 462 10.107 Duct Leakage Mechanical Ventilation Rate [CFM] System 1 Leakage to Outdoors 20 CFM @ 25Pa (1.281 100 ftZ) Total Leakage Test Type Rough -In, with Air Handler Total Leakage [CFM @ 25 Pa] 41.0 Total Leakage [CFM25 / 100 s.f.] 2.6 Total Leakage [CFM25 / CFA] 0.026 Mechanical Ventilation Rate [CFM] 44 CFM Hours per day 24.0 Fan Power Recovery Efficiency % 15 Watts 0.0 Runs at least once every 3 hrs? true Average Rate [CFM] 44.0 CFM 2010 ASHRAE 62.2 Req. Cont. Ventilation 138.2 2013 ASHRAE 62.2 Req. Cont. Ventilation 69.5 Ekotrope RATER - Version 3.2.4.2667 AP results are b?sed on data entered by Ekotrope risers Ekotrope disclaims all liabil y for the information shown on this report IECC 2012 Emissions Comparison Property Organization Inspection Status Ineenevciy,c,-,,c.cDnn 7803 W 43rd Cir EnergyLogic 2021-05-06 Wheat Ridge, CO 80033 Quinn Stedman Rater ID (RTIN): 7592832 Model: P3 E RESNET Registered Community: Westridge Builder (Confirmed) Thrive Home Builders 7803 W 43rd Cir Thrive Report Annual Carbon Dioxide (CO2) [tons/yr] 2012 IECC Rated Home Savings % Saved Heating 2.5 1.6 0.9 36.3% Cooling 0.5 0.8 -0.3 -52.8% Water Heating 1.0 1.0 0.0 0.2% Lights & Appliances 4.0 4.0 0.0 0.5% Photovoltaics -0.0 -0.0 0.0 0% TOTAL 8.0 7.4 0.6 8.1% Annual Sulfur Dioxide (SO2) [lbs/yr] 2012 IECC Rated Home Savings % Saved Heating 1.5 0.8 0.7 45.7% Cooling 0.9 1.4 -0.5 -52.8% Water Heating 0.0 0.0 0.0 0.2% Lights & Appliances 6.4 6.3 0.0 0.5% Photovoltaics -0.0 -0.0 0.0 0% TOTAL 8.8 8.5 0.3 3% Annual Nitrogen Oxide (NO.) [lbs/yr] 2012 IECC Rated Home Savings % Saved Heating 4.1 2.7 1.4 34% Cooling 0.5 0.8 -0.3 -52.8% Water Heating 2.0 1.9 0.0 0.2% Lights & Appliances 3.9 3.9 0.0 0.4% Photovoltaics -0.0 -0.0 0.0 0% TOTAL 10.4 9.3 1.1 10.9% Ekotrope RATER - Version 3.2.4.2667 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report IECC 2012 Fuel Summary Comparison Property 7803 W 43rd Cir Wheat Ridge, CO 80033 Model: P3 E Community: Westridge 7803 W 43rd Cir Thrive Report Annual Energy Cost [$/yr] Natural Gas Electric Organization EnergyLogic Quinn Stedman Builder Thrive Home Builders 2012 IECC $403 $589 Inspection Status 2021-05-06 Rater ID (RTIN): 7592832 RESNET Registered (Confirmed) Rated Home $330 $572 theenergylogtc.c<�m Savings % Saved $73 18.1% $17 2.9% Annual End -Use Cost [$/yr] 2012 IECC Rated Home Savings % Saved Heating $338 $219 $119 35.2% Cooling $60 $91 -$31 -52% Water Heating $145 $145 $0 0% Lights & Appliances $449 $447 $2 0.4% Onsite Generation -$0 -$0 $0 0% Service Charges $0 $0 $0 0% Total $992 $902 $90 9.1% Annual End -Use Consumption 2012 IECC Rated Home Savings % Saved Heating [Natural Gas Therms] 275.0 190.3 84.7 30.8% Heating [Electric kWh] 942.7 509.5 433.2 46% Cooling [Electric kWh] 555.7 849.3 -293.6 -52.8% Hot Water [Natural Gas Therms] 166.8 166.5 0.3 0.2% Lights & Appliances [Natural Gas Therms] 26.6 26.6 0.0 0% Lights & Appliances [Electric kWh] 3,974.5 3,955.5 19.0 0.5% Total [Natural Gas Therms] 468.5 383.4 85.0 18.1% Total [Electric kWh] 5,472.9 5,314.3 158.6 2.9% Total Onsite Generation kWh 0.0 0.0 0.0 0% Peak Electric Consumption 2012 IECC Rated Home Savings % Saved Peak Winter kW 0.71 0.62 0.09 13% Peak Summer kW 0.93 1.00 -0.07 -7.6% Utility Rates Electricity A Colorado E 2021 Q2 Natural Gas AColorado NG 2021 02 Ekotrope RATER - Version 3.2.4.2667 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report RESNET HOME ENERu i RAT I H G Standard Disclosure �heeneryyiog c.ccrtt For home(s) located at: 7803 W 43rd Cir, Wheat Ridge, CO Check the applicable disclosure(s): 1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. LV2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: ;,�A. Mechanical system design �PtB. Moisture control or indoor air quality consulting + C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel E. Other(specify) 3. The Rater or the Rater's employer is: [A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home lI C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home []4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products HVAC systems Installed in this home by Rater Employer OR is in the business of FjRater Employer Thermal insulation systems RaterEmployerRater Employer Air sealing of envelope or duct systems Rater L]Employer Rater Ef Employer Energy efficient appliances FiRater E]Employer DRater Employer Construction (builder, developer, construction contractor, etc) Rater [Employer Rater Employer Other (specify): I - E]Rater Employer FjRater ElEmployer F15. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 7592832 Name: Quinn Stedman Organization: EnergyLogic Signature: Digitally signed: 5/6/21 at 3:16 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are posted at https://standards-resnet.us The Home Energy Rating Standard Disclosure for this home is available from the rating provider. RESNET Form 03001-2 -Amended March 20, 2017 Y0 _ ul Q 7 p u V �C u c o is io C .� O ++ N r 3 3 a j Z) O -Q CO (D •i a! V E L' m .l ` O '° o �°o Wm to Y 63d o-'>; ■ • R ■ ■ R Z.S m 3 U O a) 4-1 v > La) Q O co c �' Q O s L� � O V ` p + • — U v to cn O `�'�. a) a} N om:+- ° � 0 .C c_ x m� o ui s ML O �- p p O tn cc Oc6 E DJ —� O 'O c � � c L- 0 •� -II > o a c o (nW '� O vi c .0 0 paill enmc) H 0 sn-I dale Joopuj ' EPA Indoor a i rPLu s b6�t /FI ED NQ&O, Thrive Home Builders EnergyLogic 2021-05-06 ZERO ENERGY READY HOME U.S. DEPARTMENT OF ENERGY YOUR HOME WAS DESIGNED, ENGINEERED, AND CONSTRUCTED IN CONFORMANCE TO U.S DEPARTMENT OF ENERGY (DOE) GUIDELINES FOR EXTRAORDINARY LEVELS OF EXCELLENCE AND QUALITY. Address Co -� 1033 Sw$dev Failtiz-1,; HER Score: *,'- ZERH Target Score: 59 ON THIS HOME MEETS OR EXCEEDS THE MINIMUM CRITERIA FOR THE FOLLOWING: ENERGY STAR V3 ENERGY STAR V3.1 2012 INTERNATIONAL ENERGY CONSERVATION CODE Emls'ing Homes Reference Home Zero Energy Home viola RESNE I SAM RASHKIN, CHIEF ARCHITECT BUILDING TECHNOLOGIES U.S. DEPARTMENT OF ENERGY More Energy Iso 1-60 130 120 Uo 100 90 80 70 60 so 40 30 zo This Home 10 0 . Less Energy Ekotrope RATER - Version 3.2.4.2667 All results are based on data entered by Ekotropa users EKOtiope disclaims all liability for the information shown on this report. Component Loads Property 7803 W 43rd Cir Wheat Ridge, CO 80033 Model: P3 E Community: Westridge 7803 W 43rd Cir Thrive Report 8 7 6 5 4 Organization EnergyLogic Quinn Stedman Builder Thrive Horne Builders Inspection Status 2021-05-06 Rater ID (RTIN): 7592832 RESNET Registered (Confirmed) Heating & Cooling Loads -A■ lheenereivr�'gic.com 1., Ij Above -Grade Infiltration & Slabs & Roofs Ducts Windows & Foundation Internal Wails Ventilation Floors Doors Walls Gains Heating ■ Cooling 0 Ekotrope RATER - Version 3.2.4.2667 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report LEED for Homes Source Energy Budget nergyl.agic Property Organization Inspection Status theenergylogic.com, 7803 W 43rd Cir EnergyLogic 2021-05-06 Wheat Ridge, CO 80033 Quinn Stedman Rater ID (RTIN): 7592832 Model: P3 E RESNET Registered Community: Westridge Builder (Confirmed) Thrive Home Builders 7803 W 43rd Cir Thrive Report This home will consume 65% less source energy than the LEED Source Energy Budget limit. Source Energy Consumption (MBtu / year)* -----_— LEED Reference -- - — As Designed - - - Heating 47.8 21.5 Cooling 5.0 5.1 Hot Water 16.6 7.9 Lights and Appliances 54.8 46.0 Onsite Generation 0.0 -36.6 Total 124.2 43.9 "Source Energy is determined by multiplying site energy electric use by 3.2 and fossil fuel use by 1.05_ Note that if there are major energy consumers not included in this energy rating (e.g. pool pumps), they must be included separately. Home Feature Summary: Home Type: Model: Community: Conditioned Floor Area: Number of Bedrooms: Primary Heating System: Primary Cooling System: Primary Water Heating: House Tightness: Ventilation: Duct Leakage to Outside Above Grade Walls: Ceiling: Window Type: Foundation Walls: Townhouse, inside unit P3 E Westridge 1,565 ftz 2 Furnace • Natural Gas • 96.5 AFUE Air Conditioner • Electric • 13 SEER Water Heater • Natural Gas • 0.96 Energy Factor 462 CFM50 (1.62ACH50) 44 CFM • 15 Watts 20 CFM @ 25Pa (1.28 / 100 ftz) R-30 Attic, R-50 U -Value: 0.3, SHGC: 0.33 N/A Ekotrope RATER - Version 3.2.4.2667 All results are based nn data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report 2005 EPAct Energy Efficient Home Tax Credit Property Organization Inspection Status 7803 W 43rd Cir EnergyLogic 2021-05-06 Wheat Ridge, CO 80033 Quinn Stedman Rater ID (RTIN): 7592832 Model: P3 E RESNET Registered Community: Westridge Builder (Confirmed) Thrive Home Builders 7803 W 43rd Cir Thrive Report RESNET Confirmed Rating Normalized Modified End -Use Loads (MBtu 1 year) Category 2006 IECC 50% As Designed Target Heating 15.2 10.1 Cooling 2.2 4.7 Total 17.4 14.8 Building Features OnergyLogic theenergylogic.com Envelope Loads (MBtu / year) Category 2006 IECC As Designed 90% Target Heating 27.3 12.3 Cooling 3.9 6.5 Total 31.2 18.8 Ceiling U: 0.02 Heating System: Furnace • Natural Gas • 96.5 Wall U: 0.044 AFUE Framed Floor U: 0.016 Cooling System: Air Conditioner • Electric • 13 Slab R: R-5 SEER Glazing Properties: U -Value: 0.3, SHGC: 0.33 Duct Leakage to Outside: 20 CFM @ 25Pa (1.281100 ft.) This home meets the requirements for the residential energy efficiency tax credit under section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005. Builder should verify that the 45L Tax Credit is available for the year in which this home was built. The undersigned certifier verifies that: (1) The dwelling unit has a projected level of annual heating and cooling energy consumption that is at least 50 percent below the annual level of heating and cooling energy consumption of a reference dwelling unit in the same climate zone; (2) Building envelope component improvements alone account for a level of annual heating and cooling energy consumption that is at least 10 percent below the annual level of heating and cooling energy consumption of a reference dwelling unit in the same climate zone; and (3) Heating and cooling energy consumption have been calculated in the manner prescribed in section 2.03 of this notice. (4) Field inspections of the dwelling unit (or of other dwelling units under the ENERGY STAR® for Homes Sampling Protocol Guidelines) performed by the eligible certifier during and after the completion of construction have confirmed that all features of the home affecting such heating and cooling energy consumption comply with the design specifications provided to the eligible certifier. "Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete." Name: Quinn Stedman Organization: EnergyLogic Signature: Digitally signed: 516/21 at 3:16 PM Ekotrope MATER - Version 3.2.4.2667 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: ) M S Job Address: -780-3 `^J 93,,1 P1 Permit Number: ` _,h2vol q I A ❑ No one available for inspection: Time /0! M Re -inspection required: Yes 1 When corrections are complete, schedule re -inspection online. Dater"��%` 20� C Inspector: DO NOT REMOVE THIS NOTICE 41 CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE I Inspection Type: Pl"I F/xZ / Job Address: F74 Permit Number: I.J No one available for inspection: Time Re -inspection required: Yes NO-) When corrections are complete, schedule re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE A Inspection Type: CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE MSS Job Address: -7 j Permit Number: 1 -t / ❑ No one available for inspection: Time AV/PM Re -Inspection required: Yes (No)i T, When corrections are complete, schedule re -inspection online. Date: _�> 2.- -,'c.,? i Inspector: zi DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address:4 �. Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes /,Novi When corrections are complete, schedule rg,inspectign online. Dat ! I i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: r Permit Number: i I I ❑ No one available for inspection: Time - _ AM/PM Re -Inspection required: i est) No When corrections are complete, schedule re -inspection online. 1 Dateda Inspecto DO NOT REMOVE THIS NOTICE 1* i CITY OF WHEAT RIDGE . Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE ; ltd �:- Inspection Type: Job Address:''' Permit Number: T ❑ No one available for inspection: Time AM/PM Re -Inspection required;/Yes" No When corrections are complete, schedule re -inspection online. Dat e° Inspector r; DO NOT REMOVE THIS NOTICE FOR OFFICE USE ONLY t Approved by. City of Steyet,Peck 2�24�2021 l _ge MUNLTY DEVELOPMENT 1nsP�t%' Date COMWheatT City ofWheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIFICATION For Commercial and Multi -Family Developments This form must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This form must be accompanied by a Construction Control Plan following the procedure found on the reverse side of this form. DATE: 11.23.20 PERMIT# 202001916 ADDRESS: 7803 WEST 43RD CIRCLE LOT 1 , BLOCK 3 YARROW GARDENS F4 SUBDIVISION SURVEYOR: I hereby certify that the elevations and distances shown on the attached sheets and as stated below for the recently formed or constructed structural foundation for the above property have been measured by me or directly under my supervision. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: 6.0' REAR: 4.0' SIDE: 0.0' SIDE: 11.2' The foundation corner ELEVATIONS (NAVDSS) have been determined to be: FRONT: 5419.60 REAR: 5419.60 SIDE: 5419.60 SIDE: 5419.60 All measurements have been determined on the following location: (Check only one): le Top of proposed foundation wall prior to placement of concrete Top of foundation wall subsequent to placement of concrete The setback and elevation measurements me included on the attached Construction Control Plan. Signed - Professional S=eyo Print Chris Madrid Date 11.23.20 www.d.wheatndge.co.us Rev 11/2018 IMPROVEMENT LOCATION CERTIFICATE FOUNDATION ONLY )Surveying, Inc. PRELIMINARY I LC peclalizing In Home Builder Services Since 1985. 6841 SOUTH YOSEMITE STREET CENTENNIAL, CO 80112 T:\Projects\YARROW GARDENS F3WARROW GARDENS F3.dwg, 11/23/2020 4:04:17 PM, kpollacl DESCRIPTION OF MONUMENTATION PO — #5 REBAR, PINK PLASTIC CAP, PLS # 38299 • — DISKS FOUND AT OFFSETS TO LOT CORNER AS SHOWN BELOW, PLS # 38299 0 20 40 SCALE: 1 "=20' IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED D0 FOR THB WestRidge LLC OF THE PROPERTY DESCRIBED AS: Q� �FL1S Mq0 ��fi LOT 1, BLOCK 3, YARROW GARDENS FILING NO. 4, CITY OF WHEATRIDGE, COUNTY OF JEFFERSON, STATE OF COLORADO; ,�fl ALSO KNOWN AS: 7803 WEST 43RD PLACE. AND THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT 382 9 LINES. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE: 11.18.20 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENTS CROSSING OR BURDENING ANY PART OF SAID PARCEL. EASEMENTS SHOWN HEREON WERE TAKEN FROM THE RECORDED PLAT DESCRIBED ABOVE,jO AND NO OTHER RESEARCH OF TITLE WAS PERFORMED IN CONNECTION WITH THIS CERTIFICATE. 1 1.18.20 LL NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS FROM WHEN YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF DATE OF SURVEY TRACT F I I PRIVATE AND EMERGENCY ACCESS AND UTILITY N00' 13'43"W 30' WATER EASEMENT EDGE of ASPHALT o ,o p oo71 B '5 ? L=7.17' FLOW LINE 17:24o o R=19.00' TOP BACK OF CUR 1-t112 1-1 S89-46'1 7j'W P 20.0 16.5 20.0 0 47.66' 3 0.0' 0 2 0.0' 1 U- 1,094 SQFT � 809 SQFT 6 1,524 SQFT LILI C>) U CU Ld z�Q JJ Co #7811 j-- TO#7809.60 W I� #7803 CY) Z g 02 -a M TOF=5419.60 TOF=5419.60 M I o C) uj 0QM Q � in • 00 Lu H U Z >Q� 2.3' Z ° a j 20.0 16.5 J O 20.0 ° o; 0 11.2' �n o cn 0 P rf , LWALK P , P 71 , S 8 z 4 a ° N00° 13'43"W 0 <mu TRACT C 22 vicr o N in T:\Projects\YARROW GARDENS F3WARROW GARDENS F3.dwg, 11/23/2020 4:04:17 PM, kpollacl DESCRIPTION OF MONUMENTATION PO — #5 REBAR, PINK PLASTIC CAP, PLS # 38299 • — DISKS FOUND AT OFFSETS TO LOT CORNER AS SHOWN BELOW, PLS # 38299 0 20 40 SCALE: 1 "=20' IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED D0 FOR THB WestRidge LLC OF THE PROPERTY DESCRIBED AS: Q� �FL1S Mq0 ��fi LOT 1, BLOCK 3, YARROW GARDENS FILING NO. 4, CITY OF WHEATRIDGE, COUNTY OF JEFFERSON, STATE OF COLORADO; ,�fl ALSO KNOWN AS: 7803 WEST 43RD PLACE. AND THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT 382 9 LINES. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE: 11.18.20 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENTS CROSSING OR BURDENING ANY PART OF SAID PARCEL. EASEMENTS SHOWN HEREON WERE TAKEN FROM THE RECORDED PLAT DESCRIBED ABOVE,jO AND NO OTHER RESEARCH OF TITLE WAS PERFORMED IN CONNECTION WITH THIS CERTIFICATE. 1 1.18.20 LL NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS FROM WHEN YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF DATE OF SURVEY FOR OFFICE USE ONLY t Approved by. City of Steyet,Peck 2�24�2021 l _ge MUNLTY DEVELOPMENT 1nsP�t%' Date COMWheatT City ofWheat Ridge Municipal Building 7500 W. 291h Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857 FOUNDATION SETBACK AND ELEVATION CERTIFICATION For Commercial and Multi -Family Developments This form must be fully completed by a Professional Land Surveyor licensed in the State of Colorado. This form must be accompanied by a Construction Control Plan following the procedure found on the reverse side of this form. DATE: 11.23.20 PERMIT# 202001916 ADDRESS: 7803 WEST 43RD CIRCLE LOT 1 , BLOCK 3 YARROW GARDENS F4 SUBDIVISION SURVEYOR: I hereby certify that the elevations and distances shown on the attached sheets and as stated below for the recently formed or constructed structural foundation for the above property have been measured by me or directly under my supervision. The MINIMUM SETBACK DISTANCES from the property lines have been determined to be: FRONT: 6.0' REAR: 4.0' SIDE: 0.0' SIDE: 11.2' The foundation corner ELEVATIONS (NAVDSS) have been determined to be: FRONT: 5419.60 REAR: 5419.60 SIDE: 5419.60 SIDE: 5419.60 All measurements have been determined on the following location: (Check only one): le Top of proposed foundation wall prior to placement of concrete Top of foundation wall subsequent to placement of concrete The setback and elevation measurements me included on the attached Construction Control Plan. Signed - Professional S=eyo Print Chris Madrid Date 11.23.20 www.d.wheatndge.co.us Rev 11/2018 IMPROVEMENT LOCATION CERTIFICATE FOUNDATION ONLY )Surveying, Inc. PRELIMINARY I LC peclalizing In Home Builder Services Since 1985. 6841 SOUTH YOSEMITE STREET CENTENNIAL, CO 80112 T:\Projects\YARROW GARDENS F3WARROW GARDENS F3.dwg, 11/23/2020 4:04:17 PM, kpollacl DESCRIPTION OF MONUMENTATION PO — #5 REBAR, PINK PLASTIC CAP, PLS # 38299 • — DISKS FOUND AT OFFSETS TO LOT CORNER AS SHOWN BELOW, PLS # 38299 0 20 40 SCALE: 1 "=20' IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED D0 FOR THB WestRidge LLC OF THE PROPERTY DESCRIBED AS: Q� �FL1S Mq0 ��fi LOT 1, BLOCK 3, YARROW GARDENS FILING NO. 4, CITY OF WHEATRIDGE, COUNTY OF JEFFERSON, STATE OF COLORADO; ,�fl ALSO KNOWN AS: 7803 WEST 43RD PLACE. AND THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT 382 9 LINES. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE: 11.18.20 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENTS CROSSING OR BURDENING ANY PART OF SAID PARCEL. EASEMENTS SHOWN HEREON WERE TAKEN FROM THE RECORDED PLAT DESCRIBED ABOVE,jO AND NO OTHER RESEARCH OF TITLE WAS PERFORMED IN CONNECTION WITH THIS CERTIFICATE. 1 1.18.20 LL NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS FROM WHEN YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF DATE OF SURVEY TRACT F I I PRIVATE AND EMERGENCY ACCESS AND UTILITY N00' 13'43"W 30' WATER EASEMENT EDGE of ASPHALT o ,o p oo71 B '5 ? L=7.17' FLOW LINE 17:24o o R=19.00' TOP BACK OF CUR 1-t112 1-1 S89-46'1 7j'W P 20.0 16.5 20.0 0 47.66' 3 0.0' 0 2 0.0' 1 U- 1,094 SQFT � 809 SQFT 6 1,524 SQFT LILI C>) U CU Ld z�Q JJ Co #7811 j-- TO#7809.60 W I� #7803 CY) Z g 02 -a M TOF=5419.60 TOF=5419.60 M I o C) uj 0QM Q � in • 00 Lu H U Z >Q� 2.3' Z ° a j 20.0 16.5 J O 20.0 ° o; 0 11.2' �n o cn 0 P rf , LWALK P , P 71 , S 8 z 4 a ° N00° 13'43"W 0 <mu TRACT C 22 vicr o N in T:\Projects\YARROW GARDENS F3WARROW GARDENS F3.dwg, 11/23/2020 4:04:17 PM, kpollacl DESCRIPTION OF MONUMENTATION PO — #5 REBAR, PINK PLASTIC CAP, PLS # 38299 • — DISKS FOUND AT OFFSETS TO LOT CORNER AS SHOWN BELOW, PLS # 38299 0 20 40 SCALE: 1 "=20' IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED D0 FOR THB WestRidge LLC OF THE PROPERTY DESCRIBED AS: Q� �FL1S Mq0 ��fi LOT 1, BLOCK 3, YARROW GARDENS FILING NO. 4, CITY OF WHEATRIDGE, COUNTY OF JEFFERSON, STATE OF COLORADO; ,�fl ALSO KNOWN AS: 7803 WEST 43RD PLACE. AND THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT 382 9 LINES. I FURTHER CERTIFY THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE: 11.18.20 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENTS CROSSING OR BURDENING ANY PART OF SAID PARCEL. EASEMENTS SHOWN HEREON WERE TAKEN FROM THE RECORDED PLAT DESCRIBED ABOVE,jO AND NO OTHER RESEARCH OF TITLE WAS PERFORMED IN CONNECTION WITH THIS CERTIFICATE. 1 1.18.20 LL NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS FROM WHEN YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF DATE OF SURVEY `®® ® CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: C__7 Al 1 / Job Address: 7'K43 W --i�� Cr 1n! Permit Number: 2,0 2-0 4 if f t ❑ No one available for inspection: Time AM/ Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online. Date: Inspector: DO NOT REMOVE THIS NOTICE January 27, 2021 TH Yarrow Gardens LLC 1875 Lawrence Street, Suite # 900 Denver, CO 80202 Re: Exterior Shear and Hold Down Letter Yarrow Gardens Townhomes 7803, 7807, 7811 W. 43rd Place L1 B3 F3 Wheat Ridge, CO 80033 7803 W 43rd PI 202001916 On January 27, 2021 EVstudio was requested to observe the installation of exterior shear walls and hold downs at the above addresses. Our representative was able to verify the exterior shear and hold downs were installed in the proper locations per the structural drawings prepared by EVstudio. This letter does not include framing or interior shear, which was inspected at a later date or gypsum, and firewalls which are to be inspected by the city. Please feel free to contact our office with any questions or concerns. Sincerely, Dominic Chapman Field Inspector Sincerely, Poo UC 46537 • . . Ross Maxwell, PE Assistant Director of Structural Engineering 5335 W 481h Ave. Suite 300 303.670.7242 ph design@evstudio.com Denver. CO 80212 303.679.1862 fax www.evstudio.com From: no-reolv(alai.wheatridae.m. us To: CommDev Pets Subject: Online Form Submittal: Revision to Permit Application Date: Monday, January 25, 20212: 16:20 PM Revision to Permit Application Permit Number 202001916 assigned to project PROPERTY INFORMATION Permit Number 202001916 Property Address 7803 W 43rd PI Property Owner Name THB Westridge LLC Property Owner Phone 303-766-7772 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email dvonfeldt@thrivehomebuilders.com Address CONTRACTOR INFORMATION Contact Name Deiavonfeldt Contact Phone Number 303-766-7772 (enter WITH dashes, eg 303-123-4567) Contact Email Address dvonfeldt@thrivehomebuilders.com Retype Contact Email dvonfeldt@thrivehomebuilders.com Address DESCRIPTION OF WORK Detailed Revised The original submitted set of floor plans for Lots 1-3, Blk 3- was Scope of Work - missing the first floor, I am uploading a revised set of plans - Provide a detailed Please restamp the revised set for the field to have onsite. description of the change in scope of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc Engineer Letter (if applicable) Additional Documents on Letter Size Are plans or documents locked for editing? Construction Plans scanned on 11'x17" or larger Additional Project Value Only add what the revised scope of work is valued at. Attach City of Wheat Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" Field not completed. Revised. BLK 3 LOTS 1-3 20210125.Ddf No Field not completed. 0 Electronic Payment Form - Revised 10-26-20 Fillable.odf SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Submitting Deia Vonfeldt Revision Email not displaying correctly? View it in your browser. ®®A CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2355 Office INSPECTION NOTICE Inspection Type: R -5 Job Address: Permit Number: 7- C2 FPO / j F ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No When corrections are complete, schedule re -Inspection online. Date inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type. Job Address: Permit Number: ❑ No one available for inspection: Time AM/PM Re -Inspection required: Yes No *When corrections have been made, schedule for re -inspection online at: httpJ/www. ci. wheatridge. co. usli,nspection Date:' l�iv G(� Inspector: DO NOT REMOVE THIS NOTICE ♦ i CITY OF WHEAT RIDGE / Building Inspection Division I (303) 235-2855 Office INSPECTION NOTICE Inspection Type: PU(-, Job Address: ,) 3 W 3=` d Y�f Permit Number: 09 0 0 /CX / (p ❑ No one available for inspection: Timeq iA /PM Re -Inspection required: Yes No When corrections are complete, schedule re -inspection online, Date:I� Inspector: DO NOT REMOVE THIS NOTICE CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: JobAddress: Permit Number: e7 Z J No one available for inspection: Time - AM/PM--, Re -inspection required: Yes No When corrections have been made, -schedule for re -inspection online at: httpL6Avww.ci. whea tridge. co. uslinspection Date: Inspector: DO NOT REMOVE THIS NOTICE I _i i CITY OF WHEAT RIDGE �/- Building Inspection Division 3 (303) 235-2855 Office � t i INSPECTION NOTICE Inspection Type: f )"'" i Job Address: Permit Number: °6_Z,,- 2 � ❑ No one available for inspection: TimeY_�;7 Re -Inspection required: Yes CNo When corrections have been http://www, ci, whea tridge, co, u for re -inspection online at: i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: V, Job Address: 7157<C-3 1-1/ �3 = Pi Permit Number: a g ❑ No one available for inspection: Time / .'*19_,r AM/PM Re -Inspection required: Yes No F' When corrections have been made`�hedule for re -inspection online at. httpYlwww. ci. wheatridge. co. uslinspection Date: Inspector: DO NOT REMOVE THIS NOTICE 3 i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: s' -- Permit Number: ❑ No one available for inspection: Time. AM/PM Re -Inspection required: Yes No When corrections have been made, schedule for re -inspection online at: h ttpYlwww, ci, wheatridge, co, usfinspection Date: r Inspector: DO NOT REMOVE THIS NOTICE i CITY OF WHEAT RIDGE Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: Job Address: Permit Number: A ❑ No one available for inspection _Time AM/PM Re -Inspection required: Yes (NO-*") When corrections have been made, sc ►e ule for re-inspectio an@ at: http✓/Z. www.ci.wheatridge.co.uslinspect n oe Dat. . i 7< ctor: Inspection Type: FO O T Job Address: Permit Number: ❑;No one available for inspection: Time i •eO_ AM/9 Re -Inspection required: Yes When corrections have been made, sc edule for re -inspection online at. httpYlwww.ci.wheatridge.co.us inspection Date: Yya ?©,'O Inspector: DNOTREMOVE THIS NOTICE i CITY OF WHEAT RIDGE - Building Inspection Division (303) 235-2855 Office INSPECTION NOTICE Inspection Type: FO O T Job Address: Permit Number: ❑;No one available for inspection: Time i •eO_ AM/9 Re -Inspection required: Yes When corrections have been made, sc edule for re -inspection online at. httpYlwww.ci.wheatridge.co.us inspection Date: Yya ?©,'O Inspector: DNOTREMOVE THIS NOTICE AGW Residential 2180 South Ivanhoe Street, Suite 5 Denver, CO 80222 Phone: (303) 759-8100 FIELD TICKET -Pending Review Report#: EF -000001 Client: TH Yarrow LLC 1875 Lawrence Street, Suite 900 Denver, CO 80202 Project: 185525-1 R 7803 W 43rd PI, Lot 1, Block 3 Yarrow Gardens Wheatridge, CO EXCAVATION AND FOOTING FORM OBSERVATIONS Activity Date: 11/12/2020 Technician: Knauff, Stephen As requested, excavation and footing form observations were performed on this date for the subject lot. The soils exposed at the current grades during our visit appear generally consistent with those found and logged in the subject soil report. It is our opinion the bearing pressures provided in the subject soil report can be used for the recommended foundation system. It is also our opinion that the footing forms, foundation void (if required), and reinforcement (if required) we observed on this date were placed in general conformance with the project plans provided to us and our recommendations. If you have any questions regarding this information, please call. Observations were conducted on a part-time, on-call basis. Cold Weather Precautions: We recommend using cold weather concreting techniques. Observations are conducted on a part-time, on-call basis (unless noted otherwise). This field report should NOT Page 1 of 1 be considered a final report since it must be reviewed by the engineer. Therefore, all information within this report and attachments (if any) are subject to review. City of Wheat Ridge Single Family New PERMIT - 202001916 PERMIT NO: 202001916 ISSUED: 10/30/2020 JOB ADDRESS: 7803 W 43rd Pl EXPIRES: 10/30/2021 JOB DESCRIPTION: Yarrow Gardens - 3 story townhome with 2 car attached garage - 1,965 sq ft total (Model P3E) - Model Showhome, no sales office *** CONTACTS *** OWNER (303)445-1618 WESTRIDGE LLC GC (303)707-4422 GENE W. MYERS 180370 THB WESTRIDGE LLC SUB (720)315-0364 GLENN CARRIZALES 130249 ULTRA ELECTRIC INC. SUB (303) 761-9276 CHRISTOPHER REISTER 170100 STEEL T HEATING, INC. SUB (303)978-1051 TODD WOODFORD 070071 C&T PLUMBING LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2936 / SHARON MANOR / WESTPARK BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 233,252.00 FEES Total Valuation 0.00 Plan Review Fee 120.00 Use Tax 41898.29 Permit Fee 11996.35 Engin. Review Fee 50.00 ** TOTAL ** 71064.64 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. No C.O. may be issued until public improvements are complete as identified in the Subdivision Improvement Agreement. All landscaping shall be installed in accordance with the approved landscape plan (WSP-20-03) prior to C.O., a landscape escrow agreement with financial guarantee in the amount of 1250 of the cost of the installation shall be required. 1* � � i City of Wheat Ridge Single Family New PERMIT - 202001916 PERMIT NO: 202001916 ISSUED: 10/30/2020 JOB ADDRESS: 7803 W 43rd Pl EXPIRES: 10/30/2021 JOB DESCRIPTION: Yarrow Gardens - 3 story townhome with 2 car attached garage - 1,965 sq ft total (Model P3E) - Model Showhome, no sales office I, by my signature, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain thispermit and perform the work described and approved in conjunction with this,permrt. I further attest that I am leg ally authorized to include alI entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY. From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: New Single -Family TOWNHOME UNIT Date: Monday, September 14, 2020 10:47:53 PM New Single -Family TOWNHOME UNIT THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. Has the Master Plan Yes been approved for this project? Name of Project 3 Plex PROPERTY INFORMATION Property Address - 7803 E 43rd Place Only enter one unit on this application Property Owner Name THB Westridge LLC Property Owner Phone 303-766-7772 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email dvonfeldt@thrivehomebuilders.com Address PLAN REVIEW CONTACT INFORMATION What Is your role? General Contractor Business Name THB Westridge LLC Main Contact Name for Deia Vonfeldt Plan Review Contact Phone Number (enter WITH dashes, eg 303-123-4567) Contact Email Address for Questions/Comments 303-766-7772 dvonfeldt@thrivehomebuilders.com Retype Contact Email dvonfeldt@thrivehomebuilders.com Address DESCRIPTION OF WORK Detailed Scope of Work - Example: New single family townhome with 2 car garage - 1,525 sq ft total (Bldg 1, B -unit) New SF TH-3 Story -2 car aft garage -MODEL SHOWHOME(no sales office) P3E-2bdrm PLUS LOFT, 2 Full Baths, 2 (5) Baths, Finished Do More Space- 1965 sq ft - Square Footage of 1,964 New Construction Foundation Plans for 11-3 Do More Foundation Plan (7803. 7807. 7811 West 43rd Specific Building Place) STAMPED pdf Elevations of Building Arch -Site -Specific -YARROW BLK 3 LOTS 1-3 20200724.pdf Site Plan showing Unit 7803 W 43rd Cir Plot Plan pdf Highlighted Floor plan of Unit Construction Plans Field not completed. scanned on 11'x17" or larger Project Value (contract $213,000 Finished: 1644sf x $122.46 = $201,324 value or cost of ALL Garage + Do More: 648sf x $48.30 = $ 31,928 materials and labor) Total: $233,252 SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Person Applying for Deia Vonfeldt Permit APPROVED 10-19-2020 -Jordan Jefferies, PE Email not displaying correctly? View it in your browser.