HomeMy WebLinkAbout11163 W. 53rd DriveMarch 30, 2021
Re: Roof Sheathing Letter
11163 W. 53rd Dr.
Lot 3 Block 1
Wheat Ridge, Colorado
On March 26, 2021 EVstudio was requested to observe the installation of the
roof sheathing at the above address.
Our representative was able to verify the roof sheathing was fully nailed and
installed properly per the structural drawings prepared by EVstudio.
Please feel free to contact our office with any questions or concerns.
Sincerely,
Dominic Chapman
Field Inspector
Sincerely,
veaaanwa �J�
L �
46537
.l .:
Ross Maxwell, PE
Assistant Director of Structural Engineer
5335 W 481h Ave. Suite 300 303.670.7242 ph design@evstudio.com
Denver. CO 80212 303.679.1862 fax www.evstudio.com
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
t -
Inspection Type:
Job Address:
Permit Number:
t
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Yes No
When corrections are complete, schedule re -inspection online.
Date:,D I �_ _ Inspector:
DO NOT REMOVE THIS NOTICE
OFFICE USE ONLY
Appr" by:
City of 1
Wheatl"dge
COMMUNITY DEVELOPMENT Inspector
2-16-21
Date
City of Wheat Ridge Municipal Building 7500 W. 29th Ave. Wheat Ridge, CO 80033-8001 P: 303.235.2846 F: 303.235.2857
FOUNDATION SETBACK AND ELEVATION CERTIFICATION
For Commercial and Multi -Family Developments
This form must be fully completed by a Professional Land Surveyor licensed in the State of
Colorado. This form must be accompanied by a Construction Control Plan following the
procedure found on the reverse side of this form.
DATE: 1/25/2021
PERMIT# #202001923
ADDRESS: 11163W. 53RD DRIVE
LOT 3 ,BLOCK 1 9 QUAIL RUN SUBDIVISION
I hereby certify that the elevations and distances shown on the attached sheets and as stated
below for the recently formed or constructed structural foundation for the above property have
been measured by me or directly under my supervision.
The MINIMUM SETBACK DISTANCES from the property lines have been determined to be:
FRONT: 10' REAR: 15' SIDE: 5 SIDE: 10' (CORNER)
The foundation corner ELEVATIONS (NAVD88) have been determined to be:
FRONT: 5483.2 REAR: 5483.2 SIDE: 5483.2 SIDE: 5483.2
All measurements have been determined on the following location:
(Check only one): )( Top of proposed foundation wall prior to placement of concrete
Top of foundation wall subsequent to placement of concrete
The setback and elevation measurements are included on
Signed
Professional Surveyor
Print
MICHAEL S. MCDANIEL .�.a.
_
Date 1/25/2021
www.cLwheatridge.co.us
cv�,
S.
l�P
(Surveyor's Sa
L Lo 00
Plan.
Rev 1 M018
Ntlld 1081NOO NOIlondISNOO O
NI930 337111d HIM 3A3HM
N
PuL21Pa2I NV,d,OaiNOO NOIionaiSNOO v
NnR �Ivno
F
. a
N
mi
s
W
U
O
W
W
W
W
S
U
i
we 4 0
� �o
Ho a
o
o '-o
o�,_
ael $
Z §00
—
w �€ c a�
a �:
�0A ,� �0-oma
�om� m
w� s aaaaa
ti
J J J J
L _
_ _ _ _ _ _ gl gl _ ____ _ _• AMV3O Gu .M
l
�
—
1 I r 11 eta l e.e i�
/, ,� �' ®� �'� 1 atle • R.S I 4- —Sao'." --F I aY ����i�
_ I
..!v..., —•out °n `' — _ ®R etli
®�
e 'ia c I II
I
i
�� � i � � �� I as • �� � �.—.adt�„ ��-' � q -° I
�_i :reqq
i�
I
„
•�� i. �� N SII 9� �� uun,. � �
eei ti ji
�PT. TlT
ti
m I
i I —rr r,r
rr r,r r,r
` CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number:
--------------
J No one available for inspection: Time
AM/PM
Re -Inspection required: Yes .No
'When corrections are complete, schedule re -inspection online.
Date: Inspector:
DO NOT REMOVE THIS NOTICE
�►A41
CITY OF WHEAT
A. Building InsRIDGE
/ Inspection Division
I (303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: i t
Job Address:
Permit Number:
❑ No one available for inspection: Ti t
Re -Inspection re m
required: Yes 4
e `- AM/PM
,o
When corrections are complete, schedu/e re -inspection online,
Dater-' I�
Inspector:
D N 7- &E
-- H� lVO /G
- - ,* � A.4, - CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
„"'• ,—
Inspection Type:. L,ri_
Job Address:
Permit Number:
__
LlNo one available for inspection: Time � ` � M/PM
Re -Inspection required: Yes ' No
When corrections are complete, schedule re -inspection online.
Date: Inspecto
DO NOT REMOVE THIS NOTICE
CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type:
Job Address:
Permit Number:
❑ No one available for inspection: Time AM/PM
Re -Inspection required: Yes No
When corrections are complete, schedule re -inspection online.
Date: 4 Inspector:
DO NOT REMOVE THIS NOTICE
January 18, 2021
Wonderland Homes
Re: Footing Inspection Letter
11163 W. 53rd Dr.
Lot 3 Block 2
Wheat Ridge, CO
EVstudio was requested on January 18, 2021 to observe the footing form construction at
the above listed address.
An EVstuido representative verified that all void, forms and steel was placed per the
construction documents prepared by EVstudio.
It is EVstudio's professional opinion that the constructed footing was placed in
substantial compliance to the plans and specifications prepared by this office for this
address and will support the anticipated loading conditions.
Please call our office with any questions or comments.
Sincerely,
Dominic Chapman
Field Inspector
pDO CCIQ
4V e. rwao�e (r, (1
46537.C*-_.-
Ross Maxwell, PE
Assistant Director of Structural Engineering
5335 W. 481h Ave. 303.670.7242 ph design@evstudio.com
Denver, CO 80212 303.679.1862 fax www.evstudio.com
11163 w 53rd dr
January 18, 2021
Wonderland Homes
Re: Footing Inspection Letter
11163 W. 53rd Dr.
Lot 3 Block 2
Wheat Ridge, CO
EVstudio was requested on January 18, 2021 to observe the footing form construction at
the above listed address.
An EVstuido representative verified that all void, forms and steel was placed per the
construction documents prepared by EVstudio.
It is EVstudio's professional opinion that the constructed footing was placed in
substantial compliance to the plans and specifications prepared by this office for this
address and will support the anticipated loading conditions.
Please call our office with any questions or comments.
Sincerely,
Dominic Chapman
Field Inspector
pDO CCIQ
4V e. rwao�e (r, (1
46537.C*-_.-
Ross Maxwell, PE
Assistant Director of Structural Engineering
5335 W. 481h Ave. 303.670.7242 ph design@evstudio.com
Denver, CO 80212 303.679.1862 fax www.evstudio.com
i CITY OF WHEAT RIDGE
Building Inspection Division
(303) 235-2855 Office
INSPECTION NOTICE
Inspection Type: SU-? C
Job Address: C t o7) ►
Permit Number: r) UCc C ! C) 7
❑ No one available for inspection: Time 10 , )AM/PM
Re -Inspection required: Yesj No
When corrections are complete, schedule re -inspection online.
Date: Inspector:
DO NOT REMOVE THIS NOTICE
City of Wheat Ridge
Single Family - New PERMIT - 202001923
PERMIT NO: 202001923 ISSUED: 01/06/2021
JOB ADDRESS: 11163 W 53rd Dr EXPIRES: 01/06/2022
JOB DESCRIPTION: Station 53 - New single family home with 2 car garage - 2,878 sq ft total
(Bl/Lot 3)
*** CONTACTS ***
OWNER
WONDERLAND HOMES
GC (303)567-7630
KOLBY O'HERRON
202128 WONDERLAND AT STATION 53
SUB (303)978-1051
TODD WOODFORD
070071 C&T PLUMBING LLC
SUB (303)650-3393
LAWRENCE GILL
022483 GILL ELECTRIC
SUB (303)289-3441
ROBERT D. GROSS,
SR.
019659 R&R HEATING & COOLING, INC
*** PARCEL INFO ***
ZONE CODE:
UA / Unassigned
USE: UA / Unassigned
SUBDIVISION CODE:
2320 / APPLERIDGE
ESTATES, STANDLEY H BLOCK/LOT#: /
*** FEE SUMMARY ***
ESTIMATED
PROJECT VALUATION: 215,919.00
FEES
Total Valuation
0.00
Plan Review Fee
120.00
Use Tax
41534.30
Permit Fee
11880.25
Engin. Review Fee
150.00
** TOTAL **
61684.55
*** COMMENTS ***
*** CONDITIONS ***
All roughs to be done at Framing Inspection.
A printed copy of the permit and city stamped on-site plans must be available on-site for
the first inspection.
Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all
applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections.
As part of the foundation inspections and PRIOR TO proceeding with any further
construction/inspections, a completed, signed and sealed, Foundation Setback and Elevation
Certification shall be submitted to the City for review. The certification form shall be
fully completed by a Professional Land Surveyor licensed in the state of Colorado, stating
that the foundation was constructed in compliance with all applicable minimum setback and
elevation requirements of the City.
Owner/Contractor is responsible for locating property lines and constructing improvements
according to the approved plan and required development standards. The City is not
responsible for inaccurate information submitted within the plan set and any construction
errors resulting from inaccurate information.
No C.O. may be issued until public improvements are complete as identified in the
Subdivision Improvement Agreement.
All landscaping shall be installed in accordance with the approved landscape plan (Case No.
WZ-18-13) prior to C.O. and pursuant to the phasing identified in the Subdivision
Improvement Agreement. Per the SIA, installation of landscaping, street trees, and
irrigation is not required prior to Certificate of Occupancy if issuance of the C.O. occurs
outside of the planting season, generally October to June.
One (1) street tree required within front setback, by time of C.O.
I, by my signatu e, do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications,
applicable build ng codes, and all applicable mu icipal codes, policies and procedu es, and that I am the legal owner or have been authorized
by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunctton with
this ermrt. I further attest that I am leggally authorized to include all entities named within this document as parties to the work to be
performed and that all work to be pertormed is disclosed n this document and or its' accompanying approved plans and specifications.
Signature of OWNER or CONTRACTOR (Circle one)
1. This permit was issued based on the information provided in the
subectto the compliance with those documents, and all applical
2. This.permit shall expire 365 days after the date of.issuance rega
received prior to the date of expiration. An extension of no more
Officlal and may be subiect to a fee equal to one-half of the one
3.
dtober
any new
Date
rmit application and accompanying plans and specifications and is
statutes, ordinances, regulations, policies and procedures.
ss of activity. Requests for extension must be made in writing and
an 180 days made be granted at the discretion of the Chief Building
1 ermitfee.
If
of a new permit shall be subject to the standard
Re -issuance or extension of expired permits is at the sole discretion of
the unlet bunging utnciai ano is not guarantees.
4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval.
5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all required
inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services
Division.
6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, an violation of any provision of any
applicable code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection.
Signature of Chief Building Official Date
REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.
From: no-reolv(alci.wheatridae.m. us
To: CommDev Farm is
Subject: Online Form Submittal: New Single -Family TOWNHOME UNIT
Date: Thursday, September 24, 2020 7:35:30 AM
New Single -Family TOWNHOME UNIT
THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN
WORK UNTIL PERMIT HAS BEEN ISSUED.
Has the Master Plan
Yes
been approved for this
project?
Name of Project
Wonderland at Station 53
PROPERTY INFORMATION
Property Address -
11163 W. 53rd Wheat Ridge, CO "`Single Family Home
Only enter one unit on
Submittal* `
this application
Property Owner Name
Wonderland at Station 53, LLC
Property Owner Phone
3035677630
Number (enter WITH
dashes, eg 303-123-
4567)
Property Owner Email
oherron@wonderlandhomes.com
Address
PLAN REVIEW CONTACT INFORMATION
What is your role?
Owner
Business Name
Wonderland at Station 53, LLC
Main Contact Name for
Michele Beckett
Plan Review
Contact Phone Number
303-915-4340
(enter WITH dashes,
eg 303-123-4567)
Contact Email Address
beckett@wonderlandhomes.com
for
Questions/Comments
Retype Contact Email beckett@wonderlandhomes.com
Address
DESCRIPTION OF WORK
Detailed Scope of
Work - Example: New
single family townhome
with 2 car garage -
1,525 sq ft total (Bldg
1, B -unit)
Square Footage of
New Construction
Foundation Plans for
Specific Building
Elevations of Building
New Single Family Home with 2 car garage -2878 sq ft total
(B1/Lot 3)
M.
11163 W 53rd Dr Foundation Plan STAMPED (1).Ddf
11163 W. 53rd Drive, Lot 3 -Elevation Plan.odf
Site Plan showing Unit 11163W 53rd Drive Lot 3 Site Plan odf
Highlighted
Floor.. .. .j..i
Construction Plans Field not completed.
scanned on 11'x17" or
larger
Finn
Project Value (contract $215,919.00 Unci
value or cost of ALL Gari
materials and labor) Tota
-d: 2878sf x $122.46 = $352,440
shed basement: 975sf x $22.45 = $21,889
436sf x $48.30 = $21,059
$395,388
SIGNATURE OF UNDERSTANDING AND AGREEMENT
I assume full
responsibility for
compliance with
applicable City of
Wheat Ridge codes
and ordinances for
work under any permit
issued based on this
application.
I understand that work
may not begin on this
property until a permit
has been issued and
posted on the property.
Yes
Yes
I certify that I have Yes
been authorized by the
legal owner of the
property to submit this
application and to
perform the work
described above.
I attest that everything Yes
stated in this
application is true and
correct and that
falsifying information in
this application is an
act of fraud and may
be punishable by fine,
imprisonment, or both.
Person Applying for Michele Beckett -agent
Permit
APPROVED
12/16/2020
J. Jefferies
Email not displaying correctly? View it in your browser.
,,,,,%%%%, Do REG.,-, �.., 0 79.8 a 7k
4 ••..• u .yam
Is
" ; q!
V �
90
0# = We 53RD DRIVE
Ilk• • • • . ` DIOIG.Iy slane0 by Michael S.
• • • • • • McDaniel
EMK
CONSULTANTS, INC. LAND
DEVELOPMENT
80.
eadc°mpuranas iholl aor be e oma!°. or •" ergrwe►a/, aoronoa e
Wily of Me wov/rbns a/ rhe Eieidp�g code s. FWma
of aw ay "amx
SERVICES
AND SOLUTIONS
ENGINEERING
SURVEYING
www.EMKC.com
7006 SOUTH ALTON WAY, BLDG. F CENTENNIAL, COLORADO 80112-2019 (303)694-1520
**OPTIONS:
—FULL UNFINISHED BASEMENT
PLOT PLAN
JOB NO.: 13185.00
LO
r
M
o
DRAWN BY: MSM
—9' BASEMENT WALLS
if
DATE: 08/31/2020
—FIREPLACE AT GREAT ROOM
STATION 53• LLC
NOTE: RAISED
—DOUBLE DOORS ® STUDY
FOUNDATION
DSF2
—AC 13 SEER
N #11163
—SUMP PUMP
NOTE:
NOTE: LOWER SIDING OR ADJUST GRADE AS
ON SITE PLANS
—TANKLESS WATER HEATER
� FULL BASEMENT
10,1'
4. LOT AREA TAKEN FROM RECORDED PLAT.
MUST BE ON SITE FOR INSPECTION
Reviewed by the City of Wheat Ridge A,
9' WALLS
ALL Projects are
Engineering Division '6
Subject to Field Inspections
NO EXCEPTIONS TAKEN
TRACT Q (SKYLINE ESTATES FIL. 1)
THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO
BY: Jordan Jefferies
' "
' LA = City of
,� vv uta ME`s`"
DATE: 12/17/2020
815 81.4
81.9 81.7 N89'3729E .
CERTIFICATION SHOWN HEREON. THIS DRAWING DOES NOT REPRESENT
Commu
COMMENTS: A grading certification
6 \s 8'0 P•U.E.
_
l�`'
Ou
�g
APPROVED
'pviewgdfQr�od��mpUanex
with ILC is required prior to CO
d 1 2%
��j q°
80.6 •
�.
ALONG THIS WALL
81.2 5' HOA A
`b
Randy Slusser 12/18/2020
°
A O0 � °
i 5
00
°
Plans Examiner Date
wdmk..r "ennll• 1Jr! kiiooeee oJe pe►raltw qvm WWF saecykotkw
,,,,,%%%%, Do REG.,-, �.., 0 79.8 a 7k
4 ••..• u .yam
Is
" ; q!
V �
90
0# = We 53RD DRIVE
Ilk• • • • . ` DIOIG.Iy slane0 by Michael S.
• • • • • • McDaniel
L5%1.
i�
82.3 4
8or3
16.0'
0_ ooDG=2
80.
eadc°mpuranas iholl aor be e oma!°. or •" ergrwe►a/, aoronoa e
Wily of Me wov/rbns a/ rhe Eieidp�g code s. FWma
of aw ay "amx
**NOTE:
DROP GARAGE FLOOR AN
PREPARED UNDER MY SUPERVISION
�, PATIO cn 12"
w
EMK CONSULTANTS, INC.
N 25
18.0'
LO
r
M
o
LOT 4
LOT 2
if
2. THIS DOCUMENT REPRESENTS A PROPOSED BUILDING LAYOUT FOR
BACKCOUNTRY RANCH
N
NOTE: RAISED
INFORMATION SHOWN IS INCLUDED BY THE CLIENT'S REQUEST AND IS
FOUNDATION
DSF2
WALL (TOF)
N #11163
TO THE EXTENT NECESSARY TO FLATTEN STEEP SIDE OR REAR SLOPES
AND NEED TO BE DESIGNED AND CONSTRUCTED PER STRUCTURAL AND
NOTE:
NOTE: LOWER SIDING OR ADJUST GRADE AS
VENEER ALONG SHOWN TO ACHIEVE
� FULL BASEMENT
10,1'
4. LOT AREA TAKEN FROM RECORDED PLAT.
5. SEWER AND WATER SERVICE LOCATIONS ARE TAKEN FROM THE
LEGAL DESCRIPTION
9' WALLS
11163 WEST 53RD DRIVE,
6. NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY
LOT 3, BLOCK 1,
LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN
19t'2
THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO
FF=84.4
EVENT, MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY
BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE
STATE OF COLORADO
CERTIFICATION SHOWN HEREON. THIS DRAWING DOES NOT REPRESENT
SETBACKS
4Cal.0' —83'2 8
4i
STEP GRADE
SIDE: 5' SIDE -CORNER: 10' 1 "-20'
ry' 3• ONE 6" FT.P,PROX.8� 2
17%
79
ALONG THIS WALL
0)
`b
RISER �S °I
RISERS
_LINE TO ACHIEVE
LOWER GRADE
j
FINISHED GRADE
ALONG PORCH AN
1' 12 CAR GARAGE
A
SHOWN. THIS MAY
ADDITIONAL 12"
N
TOF=83.2** '
AFFECT
TO ACHIEVE
ti
9.0. �;
FOUNDATION
DESIGN.
INDICATED SIDE\
o•
YARD SLOPE.
%
0 0. 21?0
4 ORCH
78.91
3 _V�5
0
23%
L
o
— %40 APPROXN IVE �'a°
RISERS -
,,,,,%%%%, Do REG.,-, �.., 0 79.8 a 7k
4 ••..• u .yam
Is
" ; q!
V �
90
0# = We 53RD DRIVE
Ilk• • • • . ` DIOIG.Iy slane0 by Michael S.
• • • • • • McDaniel
po/py DN: C=US,
', 8 Daniel E=mmcdaniel�emkacwn,
"EMIK Consultants, Inc.".
,,���','„''
CN=Mlchael S.
,. �, �,````
Data:020.08.3110:40:58-05'00'
L
**NOTE:
DROP GARAGE FLOOR AN
PREPARED UNDER MY SUPERVISION
ADDITIONAL 26” (34" TOTAL)
FOR AND ON BEHALF OF
EMK CONSULTANTS, INC.
LOT AREA: 4,516 SQUARE FEET
NOTES
U.E.=UTILITY EASEMENT
1. EASEMENTS SHOWN ON THIS PLAN ARE TAKEN FROM THE
S.E.=SIDEWALK EASEMENT
RECORDED PLAT AND MAY NOT SHOW ALL EASEMENTS OF RECORD.
DS=DROP SIDING/GRADE
2. THIS DOCUMENT REPRESENTS A PROPOSED BUILDING LAYOUT FOR
APPROVAL BY ZONING AND BUILDING AUTHORITIES. ANY OTHER
NOTE: RAISED
INFORMATION SHOWN IS INCLUDED BY THE CLIENT'S REQUEST AND IS
FOUNDATION
FOR INFORMATIONAL PURPOSES ONLY.
WALL (TOF)
3. RETAINING WALLS ARE DESIGNED HORIZONTALLY AND VERTICALLY ONLY
TO THE EXTENT NECESSARY TO FLATTEN STEEP SIDE OR REAR SLOPES
AND NEED TO BE DESIGNED AND CONSTRUCTED PER STRUCTURAL AND
NOTE:
NOTE: LOWER SIDING OR ADJUST GRADE AS
VENEER ALONG SHOWN TO ACHIEVE
GEOTECHNICAL SPECIFICATIONS BY OTHERS.
THIS WALL LINE. INDICATED SLOPE.
4. LOT AREA TAKEN FROM RECORDED PLAT.
5. SEWER AND WATER SERVICE LOCATIONS ARE TAKEN FROM THE
LEGAL DESCRIPTION
SUBDIVISION CONSTRUCTION PLANS AND SHOULD BE FIELD VERIFIED
PRIOR TO HOUSE CONSTRUCTION.
11163 WEST 53RD DRIVE,
6. NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY
LOT 3, BLOCK 1,
LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN
QUAIL RUN FINAL PLAT,
THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO
CITY OF WHEAT RIDGE, COUNTY OF JEFFERSON,
EVENT, MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY
BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF THE
STATE OF COLORADO
CERTIFICATION SHOWN HEREON. THIS DRAWING DOES NOT REPRESENT
SETBACKS
A MONUMENTED SURVEY AND IS ONLY INTENDED TO DEPICT THE
ACCOMPANYING LEGAL DESCRIPTION.
FRONT: 10' HOUSE, 15' GARAGE (18' BOW) GRAPHIC S C A L2E0
REAR: 15' a 10,
SIDE: 5' SIDE -CORNER: 10' 1 "-20'
ON SITE PLANS
MUST BE ON SITE FOR INSPECTION
ALL Projects are CTLITHOMPSON
Subject to Field Inspections
August 12, 2020
Wonderland Homes
8246 Northfield Boulevard
Building J, Suite #2600
Denver, Colorado 80238
Subject: Soils and Foundation Summary Letter
Quail Run
Block 1, Lot 3
Wheat Ridge, Colorado
Project No. DN49,619-120-R1
I HOME BUYER ADVISORY
Expansive and compressible soils and expansive bedrock
are present at this subdivision; which results in a geologic
hazard. This letter describes the soil conditions on this lot
more specifically. Prospective home buyers are strongly
advised to read this letter and the referenced documents.
If you do not understand the risk(s) associated with the
hazard and the important role you must accept to manage
and mitigate the risk(s), we recommend you contact a
competent geotechnical (soils) engineer for advice.
CTL I Thompson, Inc. performed a Soils and Foundation Investigation for
56 lots within Quail Run and presented results in a report dated July 30, 2020.
This letter presents a summary of our findings and recommendations for the sub-
ject lot. The report referenced above should be reviewed for foundation design.
Colorado is a challenging location to practice geotechnical engineering.
The climate is relatively dry and the near -surface soils are typically dry and com-
paratively stiff. These soils and related sedimentary bedrock formations tend to
react to changes in moisture conditions. Some of the soils and bedrock swell as
they increase in moisture and are referred to as expansive soils. Other soils can
compress significantly upon wetting and are identified as compressible soils.
Most of the land available for development east of the Front Range is underlain
by expansive clay or claystone bedrock near the surface. The soils that exhibit
compressible behavior are more likely west of the Continental Divide; however,
both types of soils occur throughout the state.
Expansive and compressible soils and expansive bedrock as well as shal-
low groundwater that may affect basement construction are present at this subdi-
vision, which constitutes a geologic hazard. There is risk that foundations and
slab -on -grade floors will experience heave or settlement, and damage. Covering
the ground with houses, streets, driveways, patios, etc., coupled with lawn irriga-
tion and changing drainage patterns, leads to an increase in subsurface moisture
conditions. Thus, some soil movement due to heave or settlement is inevitable.
Fill can also soften and compress upon wetting. It is critical that all recommenda-
tions in this report are followed to increase the chances that the foundations and
slabs -on -grade will perform satisfactorily. After construction, homeowners must
assume responsibility for maintaining the structures and use appropriate prac-
tices regarding drainage and landscaping. vkd, cit Of
yw>
CoMMUNUY UEWLLx'MFM'r
APPROVED
Rayl w d far Code Comaganee
Randy Slusser 8/20/2020
Plana Exwww Data
arruare� weuer°�x°w.r«W-WeIMx.x+a q�
1971 West 12th AvenueI Denver, I Phone: 303-825-0777 FaColorado 80204 Tele
.y°iw«°w,w xlwraym«d.a.ob«w.M,. xpnp
rswia xrpx° a°Mgb°bWr«siw/w�eweu ywalab
sbsalM«�r°mywOpMr ielYe111x
`�=
-..„_
In summary, the strata encountered in the boring on this lot consisted of 5
feet of fill, 8 feet of sandy Gay, and 2 feet of weathered bedrock underlain by
claystone bedroGc to the maximum depth explored of 20 feet. Nc groundwater
was encountered during this investigation. The clayey soils and bedrock are ex-
pansive. Use of footings with minimum deadload is recommended. A structurally
supported basement floor is recommended. Further details are described in fol-
lowing paragraphs.
Based on our investigation, predominantly low to moderate swelling mate-
rials an: present at depths likety to influence shallow foundation and slab perfor-
mance, and we believe there is low to moderate risk of ground movement suffi-
cient to damage slabs-on�rede and foundations. The risk of foundation and slab
movements can be mitigated, but not eliminated, by careful design, construction,
and maintenance procedures. We believe the recommendations inthis report will
help control risk of foundation and slab damage; they will not eliminate that risk.
The builder and homebuyers should understand that slabsont3rade and, in
some instances, foundations may be affected by the subsoils. Homeowner
maintenance will be required to control risk. We recommend the builder provide a
booklet to homebuyers that describes swelling soils and includes recommenda-
tionsfor care and maintenance of homes constructed on expansive soils. Colo-
rado Geologicel Survey Special Publication 431 was designed to provide this in-
formation.
Laboratory tests were performed on samples from this lot and nearby lots.
Samples from this lot did not swell and swelled 0.5 to 1 percent when wetted.
Based upon results of laboratory tests and other factors, we judge basement slab
performance risk for this lot to be low. Exhibit A provides a discussion of slab per-
formance risk evaluation, as well as slab installation and maintenance recom-
mendations. We performed calculations of total potential ground heave and
basement heave as part of our study. The calculations indicate the ground sur-
face on low risk lots included in this investigation could heave less than 0.5 -inch
to 3.2 inches and the basement floor slabs could heave less than 0.5 -inch to 2.0
inches. The calculated potential heave for this lot is 1.1 inches at the ground
surface and 0.5 inch at basement level. It is not certain this movement will occur.
If home buyers cannot tolerate movement of a slab-on�rede basement floor,
they should select a lot where a structurelty supported floor will be constructed or
request that a structurally supported floor be installed.
I'A Guitle b Swelling Soib Por Coloretlo Homebuyere antl Homeovmere; Second Etlrion Revbetl end Uptlated by Devitl
C. Nae, Cobreda Geobgkal Survey, Oepatlment of Naturel Reeaurcea, Denver, Coloredo, 2007.
QUNL RUN
aLOCKi, LOTS
Considering the subsurface conditicns at this lot, we recommend
construction of the proposed residence on a footing foundation with minimum
deadload. Footings should be designed for a maximum allowable soil pressure of
3,000 psf with a minimum deadload pressure of 1,000 psf. Footings should be at
least 16 inches in width. Column pads should be at least 18 inches square. There
should be a 4 -inch continuous void between the footings to concentrate the
deadload, if interrupted footings are necessary. Exterior footings should be
protected fiom frost action with at least 3 feet of cover. It is sometimes necessary
to alter the foundation design based on cend'rtions exposed during construction.
The buyer can discuss the changes, 'rf any, with the builder.
Basement and/ar foundation walls and grade beams that extend below
grade should be designed for lateral earth pressures where backfill is not present
to about the same extent on both sides of the wall. Our experience suggests
basement walls can deflect or rotate slightly under normal design loads and that
this deflection typically does not affect the structural integrity of the walls. We reo-
ommend design of the basement walls on this lot using an equivalent fluid den-
sity of at least 60 pounds per cubic foot. This value assumes slight deflection of
the wall can occur, generally less than 0.5 to 1 percent of the wall height. Some
minor cracking of the walls may occur.
A subsurface drain is recommended around the entire perimeter of the
lowest excevation area for this residence. The drain should lead to a positive
gravity outlet or to a sump where water can be removed with a pump. The provi-
sion of the drain will not eliminate slab movement or prevent moist conditions in
crawl spaces. The pump must be maintained by the home owner.
Proper design, construction and maintenance of surface drainage are criti-
cal to the satisfactory performance of foundations, slabs-on�rede, and other im-
provements. Landscaping and irrigation practices will also affect performance.
Exhibit B contains our recommendations for surface drainage, irrigation, and
maintenance.
The concept of risk is an important aspect with any geotechnical evalua-
tion, primarily because the methods used to develop geotechnical recommenda-
tions do not comprise an exact science. We never have complete knowledge of
subsurface conditions. Our analysis must be tempered with engineering judg-
ment and experience. Therefore, the recommendations presented in any ge-
otechnicel evaluation should not be considered risk-free. We cannot provide a
guarantee that the interaction between the soils and a proposed structure will be
as desired or intended. Our recommendations represent ourjudgment of those
measures that are necessary to increase the chances that the structure will per-
form satisfactorily. It is critical that all recommendations in the referenced report
are followed. Home owners must assume responsibility for maintaining the struo-
ture and use appropriate practices regarding drainage and landscaping.
QUNL RUR
BLOCKI, LOTS
As this letter is meant only as a summary of our findings and recommen-
dations for the subject lot, we recommend home buyers review the Soils and
Foundation Investigation from which this summary is taken.
CTL I THOMPSON, INC.
Alan J. Lisowy
Aug 12 2020
QUAIL RUN 4
BLOCK 1, LOT 3
EXHIBIT A
SLAB PERFORMANCE RISK EVALUATION,
INSTALLATION AND MAINTENANCE
As part of our evaluation of the subsoils and bedrock, samples were tested in the labore-
tory using a swell test. In the test procedure, a relatively undisturbed sample obtained during
drilling is first loaded and then flooded with water and allowed to swell. The pressure applied
prior to wetting can approximate the weight of soil above the sample depth or be some standard
load. The measured percent swell is not the sole uiteria in assessing potential movement of
slabson-grade and the risk of poor slab performance. The resuRs of a swell test on an individ-
ual lot are tempered with data from surrounding lots, depth of tests, depth of excavation, soil
profile, and other tests. This judgment has been described by the Coloredo Association of Ge-
otechnical Engineers (CAGE, 1996) as it relates to basement slab -on -grade floors. It can also
be used to help judge pertormance risk for other slabs-ony�rede such as garage floors, drive-
ways, and sidewalks. CTL Thompson also performs potential heave calculations to aid in our
judgment. The risk evaluation is considered when we evaluate appropriate foundation systems
for a given site. In generel, more conservative foundation designs are used for higher risk sites
to control the likelihood of excessive foundation movement.
As a resufl of the Slab Performance Risk Evaluation, sites are categorized as low, mod-
erate, high, or very high risk. This is a judgment of the swelling charecteris5ce of the soils and
bedrock likety to influence slab performance.
REPRESENTATNE MEASURED SWELL
AND CORRESPONDING SLAB
PERFORMANCE RISK CATEGORIES
Slab Performance
Risk Cate o
Representative Percent Swell`
500 sf Suroha a
Representative Percent Swell`
1000 sf Suroha e
Low
0 to <3
0 to <2
Motlerete
3 to <5
2 to <4
High
5 to <8
4 to <8
Very High
> 8
> 8
'Note: The representative percent swell values presented are not necessarily measured values; rether, they are
a judgment of the swelling charederistice of the sail and bedrock likely to influence slab performance.
The reting of slab performance risk on a site as low or high is not absolute. Rather, this
rating represents a judgment. Movement of slabs may occur with time in low, moderate, high,
and very high risk areas as the expansive soils respond to increases in moisture content. Over-
all, the severity and frequency of slab damage usualty is greater in high and very high rated ar-
eas. Heave of slabson�rede of 3 to 5 inches is not uncommon in areas rated as high or very
high risk. On low and moderete risk sites, slab heave of 1 to 2 inches is considered normal and
we believe in the majority of instances, movements of this magnitude constitute reasonable slab
performance; more heave can occur. Slabs can be affected on all sites. On lots refect as high or
very high risk, there is more likelihood of need to repair, maintain or replace main level and gar-
age floors and exterior flatwork.
The home buyer should be advised slabs-ony�rede may move and crack due to heave
or settlement and that there may be maintenance costs associated during and after the builder
orwL aux Exhibit A-1
BLOCK 1, LOT 3
`�=
_.:.�;_
warranty period. Heave or settlement may require maintenance of finish details to control dam-
age. Our expedence suggests that soil moisture increases below residence sites due to cover-
ing the ground with the house and exterior flatwork, coupled with the introduction of landscape
irrigation. In most cases, slab movements (if any) resulting from this change occur within three
to five years.
For portions of the houses where conventional slabs-on-grede are used, we recommend
the following precautions. These measures will not keep slabs-on�rede from heaving; they tend
to mitigate damages due to slab heave.
Slab -on -grade floor construction should be limited to areas where slab movement
and cracking are acceptable to the builder and home buyer.
2. The IMemational Residential Code (IRC R506) states that a flinch base course
layer consisting of clean graded sand, gravel, crushed stone or crushed blast fur-
nace slag shall be placed beneath below slab-on�rede floors (unless the under-
lying soils are free -draining), along with a vapor retarder. Installation of the base
course and vapor retarder is not common in this area. Historically, there has
been some cencem that installation of clean base course could allow wetting of
expansive soils to spread from an isolated source.
IRC states that the vapor retarder can be omitted where approved by the building
official. The merits of installation of a vapor retarder below floor slabs depend on
the sensitivity of floor coverings and building use to moisture. A propedy installed
vapor retarder is more beneficial below concrete slab-on-grede floors where floor
coverings, painted floor surtaces, or products stored on the floor will be sensitive
to moisture. The vapor retarder is most effective when concrete is placed directly
on top of d, rather than placing a sand or gravel leveling course between the va-
porretarder and the floor slab. Placement of concrete on the vapor retarder may
increase the risk of shrinkage cracking and cuding. Use of concrete with reduced
shrinkage charecteristice including minimized water content, maximized coarse
aggregate content, and reasonaby low slump will reduce the dsk of shdnkage
cracking and cuding. Considerations and recommendations for the installation of
vapor retarders below concrete slabs are outlined in Section 5.2.3.2 of the 2015
American Concrete Institute (ACI) Committee 302, °Guide for Concrete Floor and
Slab Construction (ACI 302.1 R-15)".
3. Conventional slabs should be separated from eMerior walls and interior bearing
members with a slip joint that allows free vertical movement of the slabs. These
joints must be maintained by the home buyer to avoid trensfer of movement.
4. Underelab plumbing (if any) should be thoroughly pressure tested during con-
struction for leaks and be provided with flexible couplings. Gas and waterlines
leading to slab -supported appliances should be constructed with flexibility. The
homebuyer must maintain these connections.
5. Use of slab bearing partitions (if any) should be minimized. Where such partitions
are necessary, a slip joint (or float) allowing at least 3 inches of free vertical slab
movement should be used. Doorways should also be designed to allow vertical
movement of slabs. To limit damage in the evert of movement, sheetrock should
OWUL RUN Exhibit A-2
BLOCK 1, LOT 3
not extend to the floor. The home buyer should monitor partition voids and other
connections and re-establish the voids before they dose to less than'frinch.
6. Plumbing and utilities that pass through slabs (if any) should be isolated from the
slabs. Heating and air cenditioning systems constructed on slabs should be pro-
vided with flexible connections capable of at least 3 inches of vertical movement
so slab movement is not transmitted to the ductwork. These connections must be
maintained by the home buyer.
Roofs that overhang a patio or porch should be constructed on the same founda-
tion as the residence. Isolated piers or pads may be installed beneath a roof
overhang provided the slab is independent of the foundation elements. Patio or
poroh roof columns may be positioned on the slab, directly above the foundation
system, provided the slab is structural and supported by the foundation system.
Structural porch or patio slabs should be constructed to reduce the likelihood that
settlement or heave will affect the slab by placing loose bac�ll under the struo-
turelly supported slab or constructing the slab over void -forming materials.
8. Patio and poroh slabs without roofs and other exterior flatwork should be isolated
from the foundation. Movements of slabs should not be transmitted to the foun-
dation. Decks are more flexible and more easily adjusted in the evert of move-
ment.
9. Frequent control joints should be provided in conventional slabs -on -grade to re-
duce problems assodated with shdnkage cracking and curling. Panels that are
approximately square generely pertorm better than rectangular areas. We sug-
gest an additional joint about 3 feet away from and parellel to foundation walls.
OWUL RUN Exhibit A-3
BLOCK 1, LOT 3
`�=
-..„_
EXHIBIT B
SURFACE DRAINAGE,
IRRIGATION AND MAINTENANCE
Performance of foundations and concrete flalwork is influenced by the moisture condi-
tions existing wdhin the foundation soils. Surface dreinage should be designed to provide rapid
runoff of surface water away from proposed residences. Proper surface drainage and irrigation
practices can help control the amount of surtace water that penetretes to foundation levels and
contributes to set8ement or heave of soils and bedrock that support foundations and slabson-
grade. Positive drainage away from the foundation and avoidance of irrigation near the founda-
tion also help to avoid excessive wetting of backfill soils, which can lead to increased backfill
settlement and possibly to higher laterel earth pressures, due to increased weight and reduced
strength of the ball. CTL � Thompson, Inc. recommends the following precautions. The home
buyer should maintain surtace dreinaoe and, if an irrioation system is installed. it should sub-
stantialN conform to these recemmendations.
Wetting or drying of the open foundation, utility and earthwork excavations
should be avoided.
2. The ground surtace surrounding the exterior of each residence should be sloped
to drain away from the building in all directions. For non -basement residences,
we recommend a minimum constructed slope of at least 8 inches in the first
10 feet (5 percent) in landscaped areas around each residence, where prectical.
For residences with basements, we recommend a minimum constructed slope of
at least 12 inches in the first 10 feet (10 percent) in landscaped areas around
each residence, where practical.
Between houses that are separated by a distance of less than 10 feet, the con-
structed slope should generelly be at least 5 percent to the swale used to convey
water out of this area.
3. Swales used to convey water across yards and between houses should be
sloped so that water moves quickly and does not pond for extended periods of
time. We suggest minimum slopes of about 2 to 2.5 percent in grassed areas and
about 2 percent where landscaping rock or other materials are present. If slopes
less than about 2 percent are necessary, concrete -lined channels or plastic pipe
should be used.
4. Backfill around the foundation walls should be moistened and compacted.
5. Roof downspouts and dreins should discharge well beyond the limits of all back-
fill. Splash blocks and/or extensions should be provided at all downspouts so wa-
terdischarges onto the ground beyond the backfill. We generally recommend
against burial of downspout discharge. Where it is necessary to bury downspout
discharge, solid, rigid pipe should be used and d should slope to an open grev'rty
outlet. Downspout extensions, splash blocks and buried outlets must be main-
tained by the home owner.
OVNL RUN Exhibit 61
BLOCK 1, LOT �
Q
0
menta. Landscaping should be carefully designed and maintained to minimize
irrigation. Plants placed close to foundation walls should be limited to those with
low moisture requirements. Irrigated grass should not be located within 5 feet of
the foundation. Sprinklers should not discharge within 5 feet of foundations. Plas-
tic sheeting should not be placed beneath landscaped areas adjacent to founda-
tion walls or grade beams. Geotextile fabric will inhibit weed growth yet still allow
natural evaporation to occur.
The design and wnstruction criteria for foundations and floor system alternatives
were compiled with the expectation that all other recommendations presented in
this report related to surface and subsurface dreinage, landscaping irrigation,
bar�ll compaction, etc. will be incorporated into the project. It is critical that all
rewmmendations in this report are followed.
OUNL RUN Exhibit 62
BLOCK 1, LOT �