ALL WORK SHALL COMPLY WITH 2018 IRC 2018 IBC 2018 IECC 2020 NEC CITY OF WHEAT RIDGE AMENDMENTS s A4r (, w ?"^ ..�_ .:.'.y, , -,f, : s I V� � \ x F (ems ti n�y,�.r 5 0 ar Wkol arts Dau Interior partitions erected on concrete slab on grade must deal with deflection and slab movement. Enclosed accessible spaces under stairs shall complywith code section R302.7 Fire Blocking and Draft Stopping shall be installed in concealed spaces per R302.11 & R302.12 1st Floorfre protection offloors shall comply with R302.13 Bathroom lighting ventilation shall comply with R303.3 Minimum Ceiling height shall be 7' or accordance with section R305.1 & R305.1.1 Fixtures in a bathroom shall meet the minimum space required per R307.1 & P2705.1 Smoke Alarms shall comply with R314.2.2 Carbon Monoxide Alarms shall comply with R315.2.2 At time of inspection, please provide the inspector with combustion, ventilation and dilution of flue gases calculations for appliances installed in the building per G2407.1 Emergency Escape shall comply with R310 uI `'' CIL, or 0p��m UN N otvtvaa � Ew. APPROVED Reviev ed Por Ccde Comorance Steven Peck 05/28/2021 Plans Examiner Date wex.m..m,a,.m,.mw.. a=,ted awmmaw.u.wMmrom vm�wnu,..nvxmex aeemMh<>an aoymma{, w �mnw. m ✓roNmeY�'wual mebinx9m�eaa/ub �M'aEavl¢n WmL O�m�^�^Bb px autha�rymW✓denmmllMponuola afine.YUULy wmaremn<.w�mnm.o/way,�xm r�.n ©MYN Boulder Environmental Inc. 5 Deer TmlReed, Denali CO 8031D Mae: (i U91195 Fee: I MID M94121 Apra 5, 2021 Ms. Jacque VTitsitt ewhitsittacomcest net CC tom(Acol order learcom RE Bulk sampling of suspected asbestos containing materials 60.50 Wert 35o` Avmuawe4 unit, Whearidge, Colorado dearMs. Whitsitt Attached is the report for the asbestos survey and bulk sampling of suspected asbestos - containing building materials at 64M Wert 2hPe savmuawest unit, Wheatridge, Canada. This investigation was conducted on behalf ofand for the exclusive use ofnds. Jacque Whhsitt(client), solely for use in a limited asbestos survey of the property. This report and the feelings herein shall not, in whole or in pact, be disseminated or conveyed to my other pary, nor used by my other park, in whole or in pact, without prior writer consent of Boulder Environmental me The results ofCar s survey are limited to materials that were assessable and foreseeable Additional materials may ear st behind hard surf any Pers onnel mowl edgeable of asbestos concerting materials shoal d always over see demolition activiti es. Demolition work shouldbe halted and sampling performed by a state of Colorado licensed buil drag inspector if earth onal materials, which are suspected of containing asbestos, are encountered If have my questions regarding the contents ofthis report, please do not hesitate to contact us Sincerel \�� Chris _ _ In,, enen Catlhy, Naeareto Maronom -_ CO Buil drag Inspector 517528 Cute 18 te2aacm Asbestos Consulting Firm 20895 'Ash III ead'Industrial Hygime'Safay'Final Air Testing' 'Heti and Safety Training' Boulder Environmental Inc. 5 Deer Trail Road, Boulder, CO 80302 Phone: (303) 449-1175 Fax:1 (866) 699-4121 BULK SAMPLING REPORT 6450 West 35' Avenue -west unit, Wheatridge, Colorado Introduction: On April 2, 2021, Boulder Environmental Inc.'s Building Inspector, Cathy Naccarato, conducted bulk sampling of suspected asbestos -containing materials under the direction of our client. Sampling: During the sampling process, suspect ACM was separated into three EPA categories. These categories are thermal system insulation (TSI), surfacing ACM, and miscellaneous ACM. TSI includes all materials used to prevent heat loss or gain or water condensation on mechanical systems. Examples of TSI are pipe coverings, boiler insulation, duct wrap, and mud packed fitting cement. Surfacing ACM includes all ACM that is sprayed, troweled, or otherwise applied to a surface. These applications are most used in fireproofing, decorative and acoustical applications. Miscellaneous materials include all ACM not listed in the thermal system insulation or surfacing categories, such as linoleum, vinyl asbestos flooring, and ceiling tile. Boulder Environmental Inc. followed EPA recommended sampling guidelines for identification of asbestos in bulk matrices. A set of three (3), five (5), or seven (7) samples were collected for each material type and analyzed by Polarized Light Microscopy (PLM). Sample locations were selected by a random selection method as described in Asbestos in Buildings, Simplified Sampling Scheme for Friable Surfacing Materials (EPA 560/5-85-03a, October 1985, AKA "Pink Book"). Suspect materials are assigned numerical values based on an evaluation of the building materials condition at the time of the inspection. The numbers assigned are: 1. Damaged or significantly damaged thermal system insulation ACM. 2. Damaged friable surfacing ACM. 3. Significantly damaged friable surfacing ACM. 4. Damaged or significantly damaged friable miscellaneous ACM. 5. ACM with potential for damage. 6. ACM with potential for significant damage. 7. Any remaining friable ACM or friable suspected ACM. *Asbestos* Lead* Industrial Hygiene* Safety *Final Air Testing* *Health and Safety Training* Boulder Environmental Inc. 5 Deer Trail Road, Boulder, CO 80302 Phone: (303) 449-1175 Fax:1 (866) 699-4121 Results: The following materials were analyzed and determined not to be asbestos containing utilizing polarized light microscopy (PLM). NON -ASBESTOS -CONTAINING SAMPLES MATERIAL SAMPLE LOCATION SAMPLE ID Textured drywall Bath east wall 4 -2 -CN -01A Bath west wall 4 -2 -CN -02A Hall ceiling 4 -2 -CN -03A Hall north wall 4 -2 -CN -04A Drywall and joint compound Bath east wall 4 -2 -CN -05 Bath west wall at mirror 4 -2 -CN -06 Sheet flooring Bath 4 -2 -CN -07 Bath 4 -2 -CN -08 Discussion: Sample analyses results are reported in percentages of asbestos and non -asbestos components. The EPA defines any material that contains greater than one percent (1%) asbestos, utilizing PLM, as being an asbestos containing material. Materials that are identified as "none detected" are specified as not containing asbestos. State Demolition Notification: A state issued demolition permit is required prior to the demolition of load bearing members. Please contact Boulder Environmental if the scope of demolition changes to include building materials that were not accessed at the time of this study. Projects involving the demolition of load bearing members may be denied the liberties conveyed by an "opt -out form". Please note that walk-in business address for CDPHE is different from the mailing address on CDPHE forms. Their physical address is 700 South Ash Street, Denver, Colorado. Please contact Boulder Environmental if the scope of demolition changes to include building materials that were not accessed at the time of this study. *Asbestos* Lead* Industrial Hygiene* Safety *Final Air Testing* *Health and Safety Training* Boulder Environmental Inc. 5 Deer Trail Road, Boulder, CO 80302 Phone: (303) 449-1175 Fax:1 (866) 699-4121 Conclusion: The following materials were determined not to be asbestos containing: • —40 square feet of textured drywall disturbed, including joint compound in cracks and joints, in the bath and hall partial walls and ceilings • —30 square feet of sheet flooring in the bath The results of this survey pertain only to materials tested. The laboratory reports supporting these findings above are attached. A state issued demolition permit is required prior to the demolition of load bearing members. If your project involves the demolition of load bearing members, please contact Boulder Environmental Inc. and we will mail you the signed demolition notification form that you must submit to attain a state of Colorado demolition permit. Please contact Boulder Environmental Inc. if you have any questions or concerns regarding this report. Sincerely, Chris Maron Project Manager *Asbestos* Lead* Industrial Hygiene* Safety *Final Air Testing* *Health and Safety Training* Reservoirs Environmental, Inc Effective October 09, 2020 Reservoirs Environmental QA Manual Q:\QAQC\Lab\Reservoirs Environmental QA Manual.pdf REI LAB Reservoirs Environmental, lnc_ April 03, 2021 Subcontractor Number: Laboratory Report: RES 490178-1 Project #/P.O. #: None Given Project Description: 6450 W 35th Cathy Naccarato Boulder Environmental, Inc. 5 Deer Trail Boulder CO 80302 Dear Cathy, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP, LLC), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 490178-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received by the customer. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, by Josh Baker Jeanne Spencer President (303) 9641986 5801 Logan St, Suite 100, Denver, CO 80216 -.reilab.com (866) RESI-ENV https://clients.reilab.com Reservoirs Environmental, Inc. Reservoirs Environmental GAManual iso: N!ZAT161IZilanWI :IQ 011LVA ia0111Mai01Lei NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number/ P.O.: Client Project Description: Date Samples Received: RES 490178-1 Boulder Environmental, Inc. None Given 6450 W 35th April 03, 2021 Effective October9, 2020 Q AGAGCALabAReservoirs Environmental GA Manual.. eat Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: April 03, 2021 Client L Asbestos Conteril Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R N M (%) (%) 4 -2 -CN -01A A Tan drywall paper 40 ND 90 10 B White texture w/ white/off white paint 60 ND 0 100 4 -2 -CN -02A A Tan drywall paper 40 ND 90 10 B White texture w/ white paint 60 ND 0 100 4 -2 -CN -03A A Tan drywall paper 35 ND 90 10 B White texture w/ white/off white paint 65 ND 0 100 4 -2 -CN -04 A White compound w/ gray/white paint 5 ND 0 100 B White texture w/ white paint 5 ND 0 100 C White compound w/ white paint 5 ND 0 100 D Off white/tan drywall 85 ND 22 78 4 -2 -CN -05 A White compound 2 ND 0 100 B White compound w/ gray/white paint 2 ND 0 100 C Off white/tan drywall 96 ND 25 75 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 wwwreilab. com Pagel of2 Reservoirs Environmental, Inc. Reservoirs Environmental GAManLot iso: N!ZAT161IZilanWI :IQ 011LVA ia0111Mai01Lei NVLAP Lab Code 101896-0 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number/ P.O.: Client Project Description: Date Samples Received: RES 490178-1 Boulder Environmental, Inc. None Given 6450 W 35th April 03, 2021 Effective October9, 2020 Q AGAGCALabAReservoirs Environmental GA Manual.. eat Method: EPA 6001R-931116 - Short Report, Bulk ND=None Detected Turnaround: Rush TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Date Samples Analyzed: April 03, 2021 Client L Asbestos Conteril Non Non - Sample A Sub Asbestos Fibrous Number Y Physical Part Mineral Visual Fibrous Components E Description Estimate Components R N M N N 4 -2 -CN -06A A White texture w/ white paint 50 ND 0 100 B Off white/tan drywall 50 ND 60 40 4 -2 -CN -07 A White paint w/ colorless resinous material 5 ND 0 100 B Off white sheet vinyl w/ gray fibrous backing material 95 ND 18 82 4 -2 -CN -08 A Off white sheet vinyl w/ gray fibrous backing material 100 ND 16 84 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. '✓%/ Josh. Baker Analyst / Data QA P'. 303-964-1986 5801 Logan Street, Suite 100, Denver, CO 80216 1-866-RESI{NV F. 303-477-4275 wwwreilab. com Page 2 of Reservoirs Environmental, Inc Reservoirs Environmental QAManual REI LAB Reservoirs En vironmen to/, /nc. Effective October 09, 2020 Q:\QAQC\Lab\Reservoirs Environmental QA Manual.pdf RES Job #: 490178 SUBMITTED BY INVOICE TO CONTACT INFORMATION SERIES Company: Boulder Environmental, Inc. .................................................................................................................................................................................................................................................. Company: Boulder Environmental, Inc. Contact: Cathy Naccarato ......................................................................................................................... -1 PLM Rush *AFTER HOURS* *VERBALS* Address: 5 Deer Trail .................................................................................................................................................................................................................................................. Address: 5 Deer Trail Phone: (303) 921-5938 ......................................................................................................................... .................................................................................................................................................................................................................................................. Fax: ......................................................................................................................... Bulk = B Boulder, CO 80302 Boulder, CO 80302 Cell: +_ o a d € € s J o € € M O N a .'F ^ '• € Project Number and/or P.O. #: None Given I Final Data Deliverable Email Address: ................................................................................................................................................................................................................................................... Project Description/Location: 6450 W 35th cathynaccarato@gmail.com (+ 3 ADDNL. CONTACTS) .................................... = D _.................................... P = SU ¢ ASBESTOS LABORATORY HOURS: Weekdays: 7am - 7pm & Sat. 8am - 5pm REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES PLM / PCM / TEM DTL IRUSH PRIORITY STANDARD Air = A Bulk = B a + L € o ' ° : +_ o a d € € s J o € € M O N a .'F ^ '• € ............................................ Dust ...................................... Paint Surface .................................... = D _.................................... P = SU ¢ Food = F Soil S Swab = SW CHEMISTRY LABORATORY HOURS: Weekdays: 8am - 5pm Dust RUSH PRIORITY STANDARD E a E E � z o � � 0a 0 3 ......................................... Tape 0 ........................................ = T Wipe = W *PRIOR NOTICE REQUIRED FOR SAME DAY TAT Metals RUSH PRIORITY STANDARD O �' a € °..........................................' cn E z v E " ° o """""""' Drinkin Water = g """""""""" DW a . i c M := i = — a: - o z: — i i _ ci } ° 3 ° - ................................................................................ Waste Water = WW Organics* SAME DAY RUSH PRIORITY STANDARD `o o f Z o m co > - < ° > _ i i �E m a� o _ � 0 � : Y o o E a ` o �:co Q cni � e , 0 2 a **ASTM E1792 approved wipe ...... media only** MICROBIOLOGY LABORATORY HOURS: Weekdays: 8am - 5pm Viable Analysis** PRIORITY STANDARD g � � + 45a ��2 � U : U a ��a � � a —TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH Q a m m a w E 5 O L � Z w 5-0 'o ° E E m E �'• o o C- Medical Device Analysis RUSH STANDARD w _ } t : _ :: a .° ro - ,2:: a a O �o� O w O off: Q: �U._Q C': .o o Oe J m o L w: m E E �� � �: E� .o Mold Analysis RUSH PRIORITY STANDARD o T N Q W Co °' _ � a: = o -2 m o a N **Turnaround times establish a laboratory priority, subject to laboratory volume and are not o 0 �, d o € guaranteed. Additional fees apply for afterhours, weekends and holidays." a Q � w _: U € F J o 0 Q J o .� o D w o a: 0: a _ M w'• ` o w€ o E Q '� ° Laborato Analysis Laboratory Y Special Instructions: a a F U : o ° 0 o ° _ 2 J N F-: W U U W: Q r E J x ° '5 ° ° t o E Instructions Client Sample ID Number (Sample I D's must be unique) ASBESTOS CHEMISTRY MICROBIOLOGY 1 4 -2 -CN -01A . . XB ....................¢......¢.................. . . X ....................$......¢.................. . . X ....................$......¢.................. . . X ....................¢......¢.................. . . X ....................¢......¢.................. . . X ....................¢......¢.................. X ...........................¢.................. X . . . . . ......¢......................¢....... . . . . . ......¢......................¢............... . . . . . ......¢......................¢....... . . . . . ......¢......................¢....... . . . . . ......¢...................................... . . . . . ......¢......................¢....... .............................................. . ¢....... . . ¢....... . ¢....... . . ¢....... . ....................... . ........................................ . ...........¢.......................... . ........................................................................... . ........................................................................... . ...........¢........... ............. ............ . . ¢.............. ........... . . B . . ........................................................................................... B . . .......................¢............ B . . B . . B ¢....................................................................................................... B ................ ............. B . . . ¢...........¢................................................................ . . . . . . . . . .................................................... . . . .................................................... . . . .................................................... ............ ............ ..................................................... 2 4 -2 -CN -02A 3 4 -2 -CN -03A 4 4 -2 -CN -04 5 4 -2 -CN -05 6 4 -2 -CN -06A 7 4 -2 -CN -07 8 4 -2 -CN -08 REI will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge. relinquished By: Cathy Naccarato Date/Time: 04/03/2021 15:07:22 Sample Condition: Acceptable received By:�Sarah Dobbs Date/Time: 04/03/2021 15:27:13 Carrier: Hand (303) 964-1986 5801 Logan St, Suite 100, Denver, CO 80216 vwvw.reilab.com (866) RESI-ENV Page 1 of 1 https:Hclients.reilab.com Boulder Environmental Inc. 5 Deer Trail Road. Boulder. CO 80302. Phor Email: ChrisraBoulderErwiromnental.com BULK SAMPLE LOG DATE: LOCATION: �qa-1 IN .668k COMPANY BILLING INFO: (866) 699-4121, .anares. - cit, z� : NAME: T C btrm n� Phone /� A[obile �i� CONSTRUCTION ERA: SCOPE: ElComplete building demolition [}Residential [3 Commercial Detached garage ❑ shed/s Renovation/restomtion ❑pop top will need a pemtit ❑ Sample per client's direction: 1000 5000sf 7 1 >5 000sf JCJ AHERA Protocol followed: SAMPLE ED 2 for mast. material, MATE s infacm materials =3 u to 1000sf. 5 for sam es BUILDING LOCATION QTY WW 1 41 rx 40 Double check:❑ Duct -work ❑ Boiler insulation ❑ Pipes (radiant / domestic) ❑ Flue ❑ Breeching cement ❑ Tmnsite ACCESSSED: ❑ Crawl space ❑ Base ent ❑ Attic insulation ripe: E] Roof : ❑ - Chk under carpeting, built up Doors Check heating system(s) Type: Steam ❑ F reed air. Baseboards. ❑ Stove FOR demo APPLICATION ❑ vital asbestos Boor tile VAT ❑ AT mastic ❑ Tar/asphalt impregnated roots Asphaltic pipe coatings ❑ Caulking ❑ Glazing ❑ other FOR demo APPLIC TION For Detached GARAGE ❑ vim I asbestos Ro r file VAT ❑ VAT mastic ❑ Tar/asphalt imp gnated mating ❑ Asphaltic pipe coatings ❑ Caulking ❑ G ang ❑ other PACM AREA(s) INACCE IBLE Samples Collected By: i - Date. Time: _ Samples Received By: Date: Time, Jack Irt✓ti,�:�� cis}. n�-i" M. it. MMINIARP-Oh-MA V C Ln c 0 0 > v w In N 0 > 0 C: c N O 0 0 000 a O E c U V v c� E. O V u C N 4' O� E� t 0 m> o E 0 - m Z) rn U> m r O F- L) U U a a N J LU U U N L O U i a� 0 E Cf J O U Q c Q O C O o U c En o -' y v Z Y � � c O m O U N L d :3 Z3 L (n 0) y U 0 a x N Q - E � L O w o U_ T C Q w O w O N a a N 0 C: W ZC O N m = U E Q in CN m NN O N o _ N Q�CR) `> a) m O-p m L N 00-0000 Q -C o Z o 0 CL Q O +) m a oa. a W fl _0 c Q 0- W z O N ED 0 U N N E w 7 0O 0 x x x N x O U w U w U N L O U i a� 0 E Cf J O U From: no-reolv(alci.wheatridae.m. us To: CommDev Farm is Subject: Online Form Submittal: Residential Interior Remodel Date: Friday, April 30, 2021 12:21:43 PM Residential Interior Remodel This application is exclusively for Residential Interior Remodels and other scopes of work which do not have a specific form already available. YOU MUST ATTACH A VALID CREDIT CARD AUTHORIZATION FORM IN ORDER FOR THE PERMIT TO BE PROCESSED. Your Permit will be emailed to the email address provided below once it is processed. THIS APPLICATION DOES NOT CONSTITUTE A PERMIT. DO NOT BEGIN WORK UNTIL PERMIT HAS BEEN ISSUED. PROPERTY INFORMATION Property Address 6450 W. 35th Ave Property Owner Name Jacque Whitsitt Property Owner Phone 970-379-8854 Number (enter WITH dashes, eg 303-123- 4567) Property Owner Email jacquewhitsitt@comcast.net Address Attach City of Wheat Electronic-Payment-Form-Blda - City of Wheat Ridae.Ddf Ridge Electronic Payment Form - "DO NOT ATTACH A PICTURE OF A CREDIT CARD" APPLICANT INFORMATION Applicant Name Price Home Improvement, LLC What is your role in the General Contractor project? Wheat Ridge 150253 Contractor's License Number (This is a 5 or 6 digit number for the City of Wheat Ridge) Contact Phone Number 303-667-6439 (enter WITH dashes, eg 303-123-4567) Contact Email Address for Plan Review Comments Retype Contractor Email Address DESCRIPTION OF WORK Detailed Scope of Work - In the space below (not as an attachment), Provide a detailed description of work including mechanical, electrical, plumbing work occurring, adding/removing walls, etc I, the applicant, understand my application will be rejected if I do not include a Detailed Scope of Work. wayne@pricehomeimprovement.com wayne@pricehomeimprovement.com Work was done at this address by a contractor what did NOT pull a permit. An inspector from Wheat Ridge saw the work and shut down the project. We are assisting in getting things back to normal for the tenant. Initial issue was Mold removal. Our Scope: Plumbing: New tub, shower body, toilet. Electrical: Verify GFCI's & Dryer outlet to code. Drywall: New drywall where removed. HVAC: Move Bathroom exhaust fan. Framing: Verify to code where access to crawl space was cut. Upgrade Smoke Detectors to code. ASBESTOS TESTING has been performed and is negative. I walked this job with the current City Chief Inspector recently. I have entered a detailed scope of work. Location of Work Bathroom, Hallway & Bedroom Square Footage Area of Work Being Performed Asbestos Report 250 Asbestos Reoort - 6450 W. 35th Ave.. odf Upload letter size 6450 W 35th Ave - BASIC Layout ndf documents here Construction Plans scanned on 11 "x17" or larger Field not completed. I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. $6000 VALUATION Project Value (contract $6000 APPROVED AS SUBMITTED value or cost of ALL SP materials and labor) SIGNATURE OF UNDERSTANDING AND AGREEMENT I assume full Yes responsibility for compliance with applicable City of Wheat Ridge codes and ordinances for work under any permit issued based on this application. I understand that work Yes may not begin on this property until a permit has been issued and posted on the property. I certify that I have Yes been authorized by the legal owner of the property to submit this application and to perform the work described above. Person Applying for Wayne Price Permit I attest that everything Yes stated in this application is true and correct and that falsifying information in this application is an act of fraud and may be punishable by fine, imprisonment, or both. Email not displaying correctly? View it in your browser. � ► � i City of Wheat Ridge Residential Remodel PERMIT - 202100862 PERMIT NO: 202100862 ISSUED: 06/02/2021 JOB ADDRESS: 6450 W 35th Ave EXPIRES: 06/02/2022 JOB DESCRIPTION: Work was done at this address by a contractor what did NOT pull a permit. An inspector from Wheat Ridge saw the work and shut down the project. We are assisting in getting things back to normal for the tenant. Initial issue was Mold removal. Our Scope: Plumbing: New tub, shower body, toilet. Electrical: Verify GFCI's & Dryer outlet to code. Drywall: New drywall where removed. HVAC: Move Bathroom exhaust fan. Framing: Verify to code where access to crawl space was cut. Upgrade Smoke Detectors to code. ASBESTOS TESTING has been performed and is negative. I walked this job with the current City Chief Inspector recently. *** CONTACTS *** OWNER (970)379-8854 WHITSITT JACQUE R GC (303)667-6439 WAYNE PRICE 150253 PRICE HOME IMPROVEMENT, LLC *** PARCEL INFO *** ZONE CODE: UA / Unassigned USE: UA / Unassigned SUBDIVISION CODE: 2405 / BARTHS, COULEHAN GRANGE, WHEAT BLOCK/LOT#: 0 / *** FEE SUMMARY *** ESTIMATED PROJECT VALUATION: 61000.00 FEES Total Valuation 0.00 Plan Review Fee 91.59 Use Tax 126.00 Permit Fee 140.90 Permit fee additiona 140.90 ** TOTAL ** 499.39 *** COMMENTS *** *** CONDITIONS *** All roughs to be done at Framing Inspection. A printed copy of the permit and city stamped on-site plans must be available on-site for the first inspection. Approved per plans and red -line notes on plans. Must comply with 2018 IRC, 2020 NEC and all applicable City of Wheat Ridge Municipal Codes. Work is subject to field inspections. 1* ► � i City of Wheat Ridge '/� Residential Remodel PERMIT - 202100862 PERMIT NO: 202100862 ISSUED: 06/02/2021 JOB ADDRESS: 6450 W 35th Ave EXPIRES: 06/02/2022 JOB DESCRIPTION: Work was done at this address by a contractor what did NOT pull a permit. An inspector from Wheat Ridge saw the work and shut down the project. We are assisting in getting things back to normal for the tenant. Initial issue was Mold removal. Our Scope: Plumbing: New tub, shower body, toilet. Electrical: Verify GFCI's & Dryer outlet to code. Drywall: New drywall where removed. HVAC: Move Bathroom exhaust fan. Framing: Verify to code where access to crawl space was cut. Upgrade Smoke Detectors to code. ASBESTOS TESTING has been performed and is negative. I walked this job with the current City Chief Inspector recently. I, by my signature , do hereby attest that the work to be performed shall comply with all accompanying approved plans and specifications, applicable building codes, and all applicable municipal codes, policies and procedures, and that I am the legal owner or have been authorized by the legal owner of the property and am authorized to obtain this permit and perform the work described and approved in conjunction with this,permrt. I further attest that I am leg ally authorized to include all entities named within this document as parties to the work to be performed and that all work to be performed is disclosed in this document and/or its' accompanying approved plans and specifications. Signature of OWNER or CONTRACTOR (Circle one) Date 1, This permit was issued based on the information provided in the permit application and accompanying plans and specifications and is subject to the compliance with those documents, and all applicable statutes, ordinances, regulations, policies and procedures. 2. This permit shall expire 365 days after the date of issuance regardless of activity. Requests for extension must be made in writing and received prior to the date of expiration. An extension of no more than 180, days made be granted at the discretion of the Chief Building Official and may be subject to a fee equal to one-half of the original permit fee. 3. If this permit expires, a new permit may be required to be obtained. Issuance of a new permit shall be subject to the standard requirements, fees and��procedures for approval of any new permit. Re -issuance or extension of expired permits is at the sole discretion of the Chief Building Official and is not guaranteed. 4. No work of any manner shall be performed that shall results in a change of the natural flow of water without prior and specific approval. 5. The permit holder shall notify the Building and Inspection Services Division in accordance with established policy of all requ�ired inspections and shall not proceed or conceal work without written approval of such work from the Building and Inspection Services Division. 6. The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, anviolation of any provision of any �pplicabje code or any ordinance or regulation of this jurisdiction. Approval of work is subject to field inspection. 06/02/2021 Signature of Chief Building Official Date REQUESTS MUST BE MADE BY 11:59PM ANY BUSINESS DAY FOR INSPECTION THE FOLLOWING BUSINESS DAY.