Loading...
HomeMy WebLinkAbout2685 Quay St Gas Sizing Calculationsrez, hnson, & sociates May 4, 2022 Building Division Wheat Ridge, CO 80033 303.235.2892 RE: 2685 Quay StreetWheat Ridge, CO 80033 This document is submitted to clarify the natural gas piping design for the above noted residence. As par[ of the renovation the homeowner has replaced the furnace, water heater and range largely in the same place. Existing piping mains are reused throughout the house. The piping as currently installed is acceptably sized per the IFGC 402.4 gas sizing calculations methods. Refer to the attached calculations and owner provided one line sketches for additional information Please do not hesitate to contact us with any questions regarding this clarification. Sincerely, �yp,DO L/CF O c A,yx� y�o 5 Darin Ramirez, PE q, 05/04/2022 Y0' Principal ey`Sp�` Ramirez, Johnson & Associates, LLC Ramirez, Johnson, and Associates, LLC 2590 Walnut St. Denver, CO 80205 720.598.0774 Page 1 of 1 mirez, hnson, & sociates PROJECT 2685 Ouay Street PROJECT JOB NAME: Wheat Ridge, CO 80033 NUMBER: 22076 BY: DWR DATE: 5/412022 Low Pressure Natural Gas Pressure Drop Calculation Dot Sized per International Fuel Gas Code 2018 -Appendix A.4 O Q AM/q `PQ Cr 0.6094 5 Calculated Presssure q 05/04/2022 Drop=Cr"L"((O/(2313•(DA2.623)))A(1/0.541)) P SSroNAX. Segment ID Pipe Diameter(in.) Length(R.) Load(MBH) Load(CFH) PD(in. w.c.) 1 0.75 5.0 172 148 0.08 2 0.75 10.0 172 148 0.15 3 0.75 12.2 172 148 0.19 4 0.75 13.3 172 148 0.20 5 0.75 9.2 172 148 0.14 6 0.75 2.0 172 148 0.03 7 0.75 2.0 172 148 0.03 13 0.5 5.0 35 30 0.03 14 0.5 6.0 35 30 0.03 35 0.5 2.7 35 30 0.02 16 0.5 2.0 35 30 0.01 Total Pressure Loss 0.91 in we Meter Inlet Pressure 6 in we Pressure Available at Appliance 5.09 in we Manufacturer Listed Minimum Pressure 3 in we Page 1 of 2 FURNACE BRANCH Segment ID Pipe Diameter(in.) Length(R.) Load(MBH) Load(CFH) PD(in. w.c.) 1 0.75 5.0 172 148 0.08 2 0.75 10.0 172 148 0.15 3 0.75 12.2 172 148 0.19 4 0.75 13.3 172 148 0.20 5 0.75 9.2 172 148 0.14 6 0.75 2.0 172 148 0.03 7 0.75 2.0 172 148 0.03 30 0.75 5.0 80 69 0.02 11 0.75 6.0 80 69 0.02 12 0.75 2.7 80 69 0.01 Total Pressure Lou 0.87 in we Meter Inlet Pressure 6 in we Manufacturer Listed Minimum Pressure Pressure Available at Appliance 5.13 in we Manufacturer Listed Minimum Pressure 5 in we RANGE BRANCH Segment ID Pipe Diameter(in.) Length(ft.) Load(MBH) Load(CFH) PD(in. w.c.) 1 0.75 5.0 172 148 0.08 2 0.75 10.0 172 148 0.15 3 0.75 12.2 172 148 0.19 4 0.75 13.3 172 148 0.20 5 0.75 9.2 172 148 0.14 6 0.75 2.0 172 148 0.03 7 0.75 2.0 172 148 0.03 8 0.5 6.0 57 49 0.09 9 0.5 6.0 57 49 0.09 Total Pressure Loss 0.99 in we Meter Inlet Pressure 6 in we Pressure Available at Appliance 5.01 in we Manufacturer Listed Minimum Pressure 4.5 in we Page 2 of 2