Loading...
HomeMy WebLinkAbout4260 Wadsworth truss reinforcementAAMARTINMART p CONSULTING N May 2, 2022 Stephen Catterall Catterall Design ice 64]] Willow Broom Trail Littleton, Colorado 80125 Re: 4230 Wadsworth Boulevard -ARC RTU Equipment Structural Review Martin/Martin, Inc. Project Number: 22.0608.5.01 Mr. Catterall: As per your request, we made a site visit to the refenced project to review the existing roof framing to verify the adequacy to support the new RTU on the roof. The approximate age of the project is 61 years, the existing bar joists are 28 -inch -deep spanning 50'-0 and spaced at S'-6 on center, we measured the chords and webs and determined from historic data from 511 that the joists are either 28tA08 or 28tA09 and the wide flange steel girder is a W 18x50 spanning 27'6 with articulation of 5'-0 over the columns. Based on the information from Edifice Builders that the new Trane 410-A RTUs weigh 1058 pounds each, we analyzed the joists as the 28LA08 per the current IEBC and the existing members satisfy the code. Based on the final curb locations with respect to the joist top chord panel points, a web stiffener may be required per the attached detall. If you have any questions, do not hesitate to call. Sincerely �Qp00 Ri C/srf 9 19531 „22022i4Z offs/ONAL W J. Michael McAffrey, PE Principal Muni/MARTIN, INC CDC 431 6100 CAA %11190 L21/2x210114 STIFFENER SUPPORTED — CONCENTRATED LOAD HANGING LOAD Us] F9l]: 1:141011:11 JOIST PANEL POINT 2117' MIN EE, TYP NOTES: 1. STIFFENER REQUIRED FOR ALL CONCENTRATED LOADS EXCEEDING 100 LBS WHERE L EXCEEDS 3" Cee 1 1 3/411=11-01 TYP JOIST CHORD SUPPORT