Loading...
HomeMy WebLinkAbout3215 Hillsied Dr Revised IsoREFER TO WASTE AND VENT RISER DIAGRAM FOR ROUTING OF PIPING OFFICE O FD MEET ST9Ra4E � / FLEx sP1�cTAF GAS UP TO STOVE (149 CFH) UP FIREPIT TO LIVING AREA O WET BAR (19 MEN) (F)SINI (23 CFH) 14-GASUP/DN FIREPLACE TO FIRE PLACE (26 MBH) (26 MBH) (63CFH) (63CFH) 1-114'G G SH BED R99H IAV RA WD ME H ` 1 1/2-G ° GAs u 1-tY1'GAS DN) CLOSET--w4.GAS FD FDD — GAS INSTANTANEOUS GAS FURNACE WATER HEATER HAVEN 240A NO MBH) (199 MBH) R8 CFH) (240 CFH) UANT PLUMBNG PLAN 4- SANITARY REFER TO ARCHITECTURAL PIANS FOR CONTINUATION SEWAGE EJECTOR SE -1 ZOELLER 2640R EQUAL -&4' DOMESTIC WAT SERVICE REFER TO ARCHITECTURAL PL FOR CONTINUATION ISOLATION VALVE 3/4'GAS UP TO FURNACE ON SECOND FLOOR IFC PIPE SIZING CALCULATION FOR PRESSURE LESS THEN 2 PSI METER DISCHARGE PRESSURE (W.C.) = 6" ALLOW PRESSURE DROP (PSI) = 0.3 TOTAL EOUNALENT OF PIPE (FEET) = 160 NOMINAL SCHED. 40 STEEL PIPE S12E(INCHES) OSCONCES 0.5 30 GAS METER INSTALLED 63 BY EXCEL ENERGY 119 TOTAL CFH = 598 246 TOTAL MSH =498 366 TOTAL EQUIVALENT LENGTH -150'-0' i—W�FRST FLOOR PLUMBING PLAN � ecveur+a 2.5 IFC PIPE SIZING CALCULATION FOR PRESSURE LESS THEN 2 PSI METER DISCHARGE PRESSURE (W.C.) = 6" ALLOW PRESSURE DROP (PSI) = 0.3 TOTAL EOUNALENT OF PIPE (FEET) = 160 NOMINAL SCHED. 40 STEEL PIPE S12E(INCHES) CAPACITY (CFH) 0.5 30 0.76 63 1 119 1.25 246 1.5 366 2 704 2.5 1122 3 1993 4 4046 5 7319 6 11851 3' GAS To AY WC iX ROOM BT BED ROOMIT-IM CLOSET I 1 1 BED ROOM LAUNDRY GAS FURNACE NKLOK GROUP BOX 914 GOLDEN,CO. 80402 Phone: 720-399-2410 KG@KLOKGROUP.COM W cn (60 MBH) DMMBY. MW GM CFH) FIDSlo% ND. OBB[liplion NNERRENSIONS 091271221 2 ASBJLLT 3' GAS To STOVE (124 MBH) (149 CFH) IBMJERECORO No Oesmption RERMR QQC 314'GASTO 7'0 FIRE PLACE SHEET CONTENTS PLUMBING FLOOR PLANS BONCE GAS UP TO (26 MBH) SCONCE (1 CFH) FIRE PIT (63CFH) DRAWING NO.: Pi A IS MBH) SCONCE D9 MBH) (1 CFH) (.B MBH) (23 CFH) I1 CFH) SCONCE (.B MBH) i./r2, FOi O (1 CFH) 314" GAS TO FIRE PLACE (26 MBH) >>G 63CFH) GAS METER METER AND SERVICE BY OTHERS TOTAL MGM -498INPUT TOTAL CFH = 598 SPECIFIC GRAVITY 0.60 0.6- PRESSURE DROP 200' EQUIVALENT LENGTH O REFER TO GAS TABLE TABL IO2A(2) FROM 2616 IFGC GAS FURNACE (40 MBH) (46 CFH) GAS INSTANTANEOUS WATER HEATER NAVIEN 240A (199 MBH) (2A6 CFH) i�GAS PPNG IBOMEIPoC i� PLUMBING GENERAL REQUIREMENTS I. PREPARE SHOP DRAWINGS OF ALL NEW WORK (INCLUDING SLEEVE LOCATIONS) TO VERIFY LOCATIONS AND COORDINATE WORK BETWEEN TRADES PRIOR TO INSTALLATION. 2. ALL DRAIN GRATES, CLEAN-0UT COVERS, AND OTHER FINISHELSEXPOSED COMPONENTS SHALL BE PROTECTED FROM DAMAGE. DAMAGED COMPONENTS SHALL BE REPLACED BY CONTRACTOR AT NO ADDITIONAL COST TO THE CONTRACT. 3. COORDINATE ROUTING OF ALL PLUMBING PIPING BELOW SLAB WITH STRUCTURAL GRADE BEAMS, TIE BEAMS, ETC. ALLOW FOR REROUTING OF PIPING AS REQUIRED. C PIPING ROUTING ON DRAWINGS IS GENERALLY DIAGRAMMATIC WITH EFFORTS MADE DURING DESIGN TO AVOID STRUCTURAL CONFLICTS. CONTRACTOR SHALL COORDINATE ROUTING OF ALL PIPING THROUGH BUILDING WITH STRUCTURAL CONDITIONS. CONTRACTOR COORDINATION DRAWINGS SHALL REFLECT ALL PIPE ROUTING AND PIPING THAT MAY HAVE TO BE SHIFTED AND/OR MOVED TO AVOID CONFLICTS. SHIFTED OR MOVED PIPING SHALL REFLECT NO ADDITIONAL COST TO THE PROJECT. 5. ALL HORIZONTAL SANITARY PIPING 3"AND SMALLER WHETHER BELOW OR ABOVE GRADE SHALL SLOPE AT 1/4" /FT. SLOPE. ALL PIPING A' AND LARGER SHALL SLOPE AT 118'/FT. SLOPE UNLESS OTHERWISE NOTED. 6. IN ADDITION TO THE CLEAN-OUT LOCATIONS SHOWN ON DRAWINGS, CLEANOUTS SHALL BE PROVIDED PROVIDED IN ACCORDANCE WITH THE LOCAL GOVERNING CODE. ADDITIONAL CLEANWTS SHALL BE PROVIDED AS FOLLOWS: 6.1. EACH RUN OF PIPING WHICH IS MORE THAN 75 FEET IN LENGTH OR FRACTION 1HEREOF. 6.2. HORIZONTAL LINES 5 FEET OR GREATER. 6.3, HORIZONTAL LINES FOR EACH AGGREGATE CHANGE OF DIRECTION EXCEEDING 135 DEGREES. 6.6. AT THE BASE OF ALL SANITARY RISERS. ALL VERTICAL CLEANOUTS SHALL BE SIZED TO ACCOMMODATE THE LARGEST PIPE ON THAT BRANCH LINE, BUT NEVER LARGER THAN 4'. CODES AND DESIGN CRITERIA: JURISDICTION. WHEAT RIME, CO PLUMBING CODE: 2018 IRC BUILDINGTYPE: RESIDENTIAL TOTAL SANITARY WASTE LOAD: 38 DFII (EA) TB C 2"FD NKLOK GROUP BOX 914 GOLDEN,CO. 80402 Phone: 720-399-2410 KG@KLOKGROUP.COM W cn O LLJ CD0 Q n J W J_ _ 2 rl N M DMMBY. MW CHBO(EDV. LR FIDSlo% ND. OBB[liplion NNERRENSIONS 091271221 2 ASBJLLT 0612C= IBMJERECORO No Oesmption RERMR OI�N�221 SHEET CONTENTS PLUMBING FLOOR PLANS �O.OpPDO UCF,ysfo is FfS�ONAL ENA'\�4. 6/24/2022 DATE: 07*20 DRAWING NO.: Pi A